Climate parameters
The Nissan ARIYA has 12 climate parameters.
● Confirmed◆ In testing○ Supported× Not supported
Air conditioning compressor speed ARIYA_AC_COMP_RPM
- Request
21 10 - Service 21
PID 10 - Module
744 → 764 - Every
5 s - Testing
Bits 168 to 183 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 2022 to 2026.
Air conditioning on ARIYA_HVAC_AC_ON
- Request
21 10 - Service 21
PID 10 - Module
744 → 764 - Every
5 s - Testing
Bit 80 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2022 to 2026.
Air conditioning status ARIYA_AC_STATUSConfirmed
- Request
22 40 07 - Service 22
DID 4007 - Module
744 → 764 - Every
5 s - Testing for 2022, 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Off or on
Confirmed for 2023 to 2025. In testing for 2022, 2026.
Ambient air temperature AATSAE J1979Confirmed
- Request
01 46 - Service 01
PID 46 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2024 to 2025. Supported for 2023.
Ambient air temperature ARIYA_AATConfirmed
- Request
22 40 08 - Service 22
DID 4008 - Module
744 → 764 - Every
5 s - Testing for 2022, 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2023 to 2025. In testing for 2022, 2026.
Ambient air temperature, climate module ARIYA_HVAC_AAT
- Request
21 10 - Service 21
PID 10 - Module
744 → 764 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2022 to 2026.
Blower on ARIYA_HVAC_FAN_ON
- Request
21 10 - Service 21
PID 10 - Module
744 → 764 - Every
5 s - Testing
Bit 88 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2022 to 2026.
Blower voltage ARIYA_HVAC_BLOWER_V
- Request
21 10 - Service 21
PID 10 - Module
744 → 764 - Every
5 s - Testing
Bits 89 to 95 of the reply, 7 bits.
- Formula
val- Range
- 0 to 127 V
- Unit
- V
In testing for 2022 to 2026.
Cabin temperature ARIYA_HVAC_CABIN_T
- Request
21 10 - Service 21
PID 10 - Module
744 → 764 - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2022 to 2026.
Coolant temperature ARIYA_ECT
- Request
22 F4 67 - Service 22
DID F467 - Module
744 → 764 - Every
5 s - Testing for 2022, 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2022, 2026. Supported for 2023 to 2025.
Evaporator temperature ARIYA_HVAC_EVAP_T
- Request
21 10 - Service 21
PID 10 - Module
744 → 764 - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2022 to 2026.
Sun load ARIYA_HVAC_SUNLOAD
- Request
21 10 - Service 21
PID 10 - Module
744 → 764 - Every
5 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2022 to 2026.