Battery parameters
The Polestar 2 has 43 battery parameters.
● Confirmed◆ In testing○ Supported× Not supported
12V battery state of charge POLESTAR2_12V_BAT_ST_CHG
- Request
22 49 46 - Service 22
DID 4946 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 1024 ÷ 15625)- Range
- 0 to 4294 %
- Unit
- %
In testing for 2020 to 2021, 2023 to 2026. Not supported for 2022.
Auxiliary battery current POLESTAR2_AUXILIARY_BAT
- Request
22 41 12 - Service 22
DID 4112 - Module
D01A → 1F402E80 - Every
1 s - Testing for 2020 to 2021, 2023 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 127)- Range
- -127 to 128 A
- Unit
- A
In testing for 2020 to 2021, 2023 to 2026. Supported for 2022.
Auxiliary battery temperature POLESTAR2_AUXILIARY_BAT_T
- Request
22 40 D3 - Service 22
DID 40D3 - Module
D01A → 1F402E80 - Every
5 s - Testing for 2020 to 2021, 2023 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2020 to 2021, 2023 to 2026. Supported for 2022.
Auxiliary battery voltage POLESTAR2_AUXILIARY_BAT_V
- Request
22 41 7E - Service 22
DID 417E - Module
D01A → 1F402E80 - Every
5 s - Testing for 2020 to 2021, 2023 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2020 to 2021, 2023 to 2026. Supported for 2022.
Average static low range battery current POLESTAR2_AVG_STATIC_LOW_RANGE
- Request
22 40 25 - Service 22
DID 4025 - Module
D01A → 1F402E80 - Every
1 s - Testing for 2020 to 2021, 2023 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val − 511)- Range
- -511 to 65024 mA
- Unit
- mA
In testing for 2020 to 2021, 2023 to 2026. Supported for 2022.
Battery current POLESTAR2_BAT_CURRENT
- Request
22 40 90 - Service 22
DID 4090 - Module
D01A → 1F402E80 - Every
1 s - Testing for 2020 to 2021, 2023 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 512)- Range
- -512 to 3583 A
- Unit
- A
In testing for 2020 to 2021, 2023 to 2026. Supported for 2022.
Battery voltage POLESTAR2_BAT_V
- Request
22 40 CD - Service 22
DID 40CD - Module
D01A → 1F402E80 - Every
5 s - Testing for 2020 to 2021, 2023 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 40 + 5)- Range
- 0 to 1643 V
- Unit
- V
In testing for 2020 to 2021, 2023 to 2026. Supported for 2022.
Charge power limit POLESTAR2_CHG_POWER_LIM
- Request
22 48 9C - Service 22
DID 489C - Module
D016 → 1EC6AE80 - Every
1 s - Testing for 2020 to 2021, 2023 to 2026
Bits 0 to 23 of the reply, 24 bits.
- Formula
(val × 4 ÷ 15625)- Range
- 0 to 4294 kW
- Unit
- kW
In testing for 2020 to 2021, 2023 to 2026. Supported for 2022.
Charger cable selected current POLESTAR2_CHARGER_CABLE
- Request
22 EE 8D - Service 22
DID EE8D - Module
D016 → 1EC68E80 - Every
1 s - Testing for 2020 to 2021, 2023 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 410)- Range
- -410 to 6143 A
- Unit
- A
In testing for 2020 to 2021, 2023 to 2026. Supported for 2022.
Charging socket, locked POLESTAR2_CHG_SOCKET_LOCKED
- Request
22 EE 8C - Service 22
DID EE8C - Module
D016 → 1EC68E80 - Every
1 s - Testing for 2020 to 2021, 2023 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2021, 2023 to 2026. Supported for 2022.
Control module supply voltage POLESTAR2_ENG_CTRL_MODULE_SUP_V
- Request
22 F4 42 - Service 22
DID F442 - Module
D016 → 1EC6AE80 - Every
5 s - Testing for 2020 to 2021, 2023 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2020 to 2021, 2023 to 2026. Supported for 2022.
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Request
01 42 - Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65535 V
- Unit
- V
Confirmed for 2021 to 2024.
DC charger current POLESTAR2_DC_CHARGER_CURRENT
- Request
22 EE 16 - Service 22
DID EE16 - Module
D016 → 1EC68E80 - Every
1 s - Testing for 2020 to 2021, 2023 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 A
- Unit
- A
In testing for 2020 to 2021, 2023 to 2026. Supported for 2022.
DC charger voltage POLESTAR2_DC_CHARGER_V
- Request
22 EE 17 - Service 22
DID EE17 - Module
D016 → 1EC68E80 - Every
1 s - Testing for 2020 to 2021, 2023 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 V
- Unit
- V
In testing for 2020 to 2021, 2023 to 2026. Supported for 2022.
Discharge power limit POLESTAR2_DCHG_POWER_LIM
- Request
22 48 9E - Service 22
DID 489E - Module
D016 → 1EC6AE80 - Every
1 s - Testing for 2020 to 2021, 2023 to 2026
Bits 0 to 23 of the reply, 24 bits.
- Formula
(val × 4 ÷ 15625)- Range
- 0 to 4294 kW
- Unit
- kW
In testing for 2020 to 2021, 2023 to 2026. Supported for 2022.
External temperature sensor, HV battery cooling module POLESTAR2_EXTERNAL_T_SENS
- Request
22 EE 46 - Service 22
DID EE46 - Module
D016 → 1EC60E80 - Every
5 s - Testing for 2020 to 2021, 2023 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.14)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2020 to 2021, 2023 to 2026. Supported for 2022.
Fuse DC charging voltage POLESTAR2_FUSE_DC_CHG_V
- Request
22 49 8B - Service 22
DID 498B - Module
D016 → 1EC6AE80 - Every
1 s - Testing for 2020 to 2021, 2023 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 V
- Unit
- V
In testing for 2020 to 2021, 2023 to 2026. Supported for 2022.
High voltage battery - voltage at IEM fuse POLESTAR2_HVBAT_V_IEM_FUSE
- Request
22 48 59 - Service 22
DID 4859 - Module
D016 → 1EC6AE80 - Every
1 s - Testing for 2020 to 2021, 2023 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 V
- Unit
- V
In testing for 2020 to 2021, 2023 to 2026. Supported for 2022.
High voltage battery - voltage at IHFA fuse POLESTAR2_HVBAT_V_IHFA_FUSE
- Request
22 48 58 - Service 22
DID 4858 - Module
D016 → 1EC6AE80 - Every
1 s - Testing for 2020 to 2021, 2023 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 V
- Unit
- V
In testing for 2020 to 2021, 2023 to 2026. Supported for 2022.
High voltage battery cell voltage sum POLESTAR2_HVBAT_CELL_VOLTAGES
- Request
22 49 7C - Service 22
DID 497C - Module
D016 → 1EC6AE80 - Every
1 s - Testing for 2020 to 2021, 2023 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 V
- Unit
- V
In testing for 2020 to 2021, 2023 to 2026. Supported for 2022.
High voltage battery contactor voltage POLESTAR2_HVBAT_CONTACTOR_V
- Request
22 48 57 - Service 22
DID 4857 - Module
D016 → 1EC6AE80 - Every
1 s - Testing for 2020 to 2021, 2023 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 V
- Unit
- V
In testing for 2020 to 2021, 2023 to 2026. Supported for 2022.
High voltage battery coolant inlet temperature POLESTAR2_HVBAT_CLT_INLET_T
- Request
22 48 04 - Service 22
DID 4804 - Module
D016 → 1EC6AE80 - Every
1 s - Testing for 2020 to 2021, 2023 to 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 °C
- Unit
- °C
In testing for 2020 to 2021, 2023 to 2026. Supported for 2022.
High voltage battery coolant outlet temperature POLESTAR2_HVBAT_CLT_OUTLET_T
- Request
22 49 90 - Service 22
DID 4990 - Module
D016 → 1EC6AE80 - Every
1 s - Testing for 2020 to 2021, 2023 to 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 °C
- Unit
- °C
In testing for 2020 to 2021, 2023 to 2026. Supported for 2022.
High voltage battery current POLESTAR2_HVBAT_CURRENT
Pelican can show this parameter as the traction battery current.
- Request
22 48 02 - Service 22
DID 4802 - Module
D016 → 1EC6AE80 - Every
1 s - Testing for 2020 to 2021, 2023 to 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 A
- Unit
- A
In testing for 2020 to 2021, 2023 to 2026. Supported for 2022.
High voltage battery negative contactor voltage POLESTAR2_HVBAT_NEGATIVE_V
- Request
22 4A 58 - Service 22
DID 4A58 - Module
D016 → 1EC6AE80 - Every
1 s - Testing for 2020 to 2021, 2023 to 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 V
- Unit
- V
In testing for 2020 to 2021, 2023 to 2026. Supported for 2022.
High voltage battery state of charge POLESTAR2_HVBAT_ST_CHG
Pelican can show this parameter as the state of charge.
- Request
22 48 01 - Service 22
DID 4801 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 500)- Range
- 0 to 131 %
- Unit
- %
In testing for 2020 to 2021, 2023 to 2026. Not supported for 2022.
High voltage battery state of health POLESTAR2_HVBAT_ST_HEALTH
Pelican can show this parameter as the state of health.
- Request
22 49 6D - Service 22
DID 496D - Module
D016 → 1EC6AE80 - Every
1 s - Testing for 2020 to 2021, 2023 to 2026
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 100)- Range
- 0 to 42949672 %
- Unit
- %
In testing for 2020 to 2021, 2023 to 2026. Supported for 2022.
High voltage battery voltage POLESTAR2_HVBAT_V
Pelican can show this parameter as the traction battery voltage.
- Request
22 48 03 - Service 22
DID 4803 - Module
D016 → 1EC6AE80 - Every
5 s - Testing for 2020 to 2021, 2023 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 2020 to 2021, 2023 to 2026. Supported for 2022.
High voltage battery, average temperature POLESTAR2_HVBAT_AVG_T
- Request
22 49 1B - Service 22
DID 491B - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100 − 50)- Range
- -50 to 605 °C
- Unit
- °C
In testing for 2020 to 2021, 2023 to 2026. Not supported for 2022.
High voltage battery, coolant pump speed, actual POLESTAR2_HVBAT_CLT_PMP_SPD_ACT
- Request
22 48 67 - Service 22
DID 4867 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 24)- Range
- 0 to 6120 rpm
- Unit
- rpm
In testing for 2020 to 2021, 2023 to 2026. Not supported for 2022.
High voltage battery, coolant pump speed, requested POLESTAR2_HVBAT_CLT_PMP_SPD
- Request
22 48 66 - Service 22
DID 4866 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 24)- Range
- 0 to 6120 rpm
- Unit
- rpm
In testing for 2020 to 2021, 2023 to 2026. Not supported for 2022.
High voltage battery, high-voltage coolant heater fuse voltage POLESTAR2_HVBAT_HVCH_FUSE_V
- Request
22 48 0A - Service 22
DID 480A - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 V
- Unit
- V
In testing for 2020 to 2021, 2023 to 2026. Not supported for 2022.
High voltage battery, IEM fuse voltage POLESTAR2_HVBAT_IEM_FUSE_V
- Request
22 48 08 - Service 22
DID 4808 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 V
- Unit
- V
In testing for 2020 to 2021, 2023 to 2026. Not supported for 2022.
High voltage battery, IGM fuse voltage POLESTAR2_HVBAT_IGM_FUSE_V
- Request
22 48 09 - Service 22
DID 4809 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 V
- Unit
- V
In testing for 2020 to 2021, 2023 to 2026. Not supported for 2022.
High voltage battery, max temperature POLESTAR2_HVBAT_MAX_T
- Request
22 49 45 - Service 22
DID 4945 - Module
D016 → 1EC6AE80 - Every
1 s - Testing for 2020 to 2021, 2023 to 2026
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 100 − 50)- Range
- -50 to 605 °C
- Unit
- °C
In testing for 2020 to 2021, 2023 to 2026. Supported for 2022.
High voltage battery, OBC fuse voltage POLESTAR2_HVBAT_OBC_FUSE_V
- Request
22 48 0B - Service 22
DID 480B - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 V
- Unit
- V
In testing for 2020 to 2021, 2023 to 2026. Not supported for 2022.
High voltage system voltage POLESTAR2_HIGH_V_SYSTEM_V
- Request
22 98 5C - Service 22
DID 985C - Module
D016 → 1EC6EE80 - Every
1 s - Testing for 2020 to 2021, 2023 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383 V
- Unit
- V
In testing for 2020 to 2021, 2023 to 2026. Supported for 2022.
High voltage system voltage POLESTAR2_HIGH_V_SYSTEM_V_D016
- Request
22 98 5C - Service 22
DID 985C - Module
D016 → 1ED24E80 - Every
1 s - Testing for 2020 to 2021, 2023 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383 V
- Unit
- V
In testing for 2020 to 2021, 2023 to 2026. Supported for 2022.
Hybrid battery pack remaining charge BAT_SOCSAE J1979Confirmed
The percent remaining level of charge for a battery pack used for propulsion, expressed as a percentage of total useable battery energy, commonly referred to as State Of Charge (SOC).
Pelican can show this parameter as the state of charge.
- Request
01 5B - Service 01
PID 5B - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2021 to 2024.
Main charger current POLESTAR2_MAIN_CHARGER_CURRENT
- Request
22 EE 15 - Service 22
DID EE15 - Module
D016 → 1EC68E80 - Every
1 s - Testing for 2020 to 2021, 2023 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 A
- Unit
- A
In testing for 2020 to 2021, 2023 to 2026. Supported for 2022.
Main charger voltage POLESTAR2_MAIN_CHARGER_V
- Request
22 EE 1C - Service 22
DID EE1C - Module
D016 → 1EC68E80 - Every
1 s - Testing for 2020 to 2021, 2023 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 2020 to 2021, 2023 to 2026. Supported for 2022.
Module voltage POLESTAR2_MODULE_V
- Request
22 D1 11 - Service 22
DID D111 - Module
D016 → 1EC70E80 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2020 to 2021, 2023 to 2026. Not supported for 2022.
State of charge POLESTAR2_SOC
- Request
22 40 28 - Service 22
DID 4028 - Module
D01A - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 100 %
- Unit
- %
In testing for 2025. Not supported for 2020 to 2024, 2026.