Polestar 3

Battery parameters

The Polestar 3 has 353 battery parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

12V battery state of charge POLESTAR_12V_BAT_ST_CHG

  • Request22 49 46
  • Service 22DID 4946
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 1024 ÷ 15625)
Range
0 to 4294 %
Unit
%

In testing for 2024 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

12V battery state of charge POLESTAR_12V_BAT_ST_CHG

  • Request22 49 46
  • Service 22DID 4946
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 1024 ÷ 15625)
Range
0 to 4294 %
Unit
%

In testing for 2024 to 2026.

12V system voltage, hd POLESTAR_EQA_AUX_V_HD

Pelican can show this parameter as the starter battery voltage.

  • Request22 02 01
  • Service 22DID 0201
  • Module624 → 5A4
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 1000 ÷ 10000)
Range
0 to 100 V
Unit
V

In testing for 2024 to 2026.

All-wheel drive coupling module voltage POLESTAR_MECU_V

  • Request22 DD 02
  • Service 22DID DD02
  • Module795
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 4)
Range
0 to 63.75 V
Unit
V

In testing for 2024 to 2026.

Alternator charge voltage request POLESTAR_ALTERNATOR_CHG_V_REQ

  • Request22 41 1D
  • Service 22DID 411D
  • Module726
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 V
Unit
V

In testing for 2024 to 2026.

Auxiliary battery current POLESTAR_AUXILIARY_BAT

  • Request22 41 12
  • Service 22DID 4112
  • ModuleD01A → 1F402E80
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 127)
Range
-127 to 128 A
Unit
A

In testing for 2024 to 2026.

Auxiliary battery temperature POLESTAR_AUXILIARY_BAT_T

  • Request22 40 D3
  • Service 22DID 40D3
  • ModuleD01A → 1F402E80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2024 to 2026.

Auxiliary battery voltage POLESTAR_AUXILIARY_BAT_V

  • Request22 41 7E
  • Service 22DID 417E
  • ModuleD01A → 1F402E80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 V
Unit
V

In testing for 2024 to 2026.

Auxiliary battery voltage POLESTAR_EQA_AUX_V

Pelican can show this parameter as the starter battery voltage.

  • Request22 20 05
  • Service 22DID 2005
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 25.9 ÷ 255)
Range
0 to 25.9 V
Unit
V

In testing for 2024 to 2026.

Average static low range battery current POLESTAR_AVG_STATIC_LOW_RANGE

  • Request22 40 25
  • Service 22DID 4025
  • ModuleD01A → 1F402E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val − 511)
Range
-511 to 65024 mA
Unit
mA

In testing for 2024 to 2026.

Battery age condition POLESTAR_ED_BAT_AGE

  • Request22 63 08
  • Service 22DID 6308
  • Module7E5 → 7ED
  • Every600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127.5 %
Unit
%

In testing for 2024 to 2026.

Battery charge balance, ah POLESTAR_BAT_CHG_BALANCE_AH

  • Request22 41 A5
  • Service 22DID 41A5
  • Module726
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2024 to 2026.

Battery charge, amps POLESTAR_BAT_CHG_AMPS

  • Request22 40 90
  • Service 22DID 4090
  • Module726
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 511.7)
Range
-511 to 3584 A
Unit
A

In testing for 2024 to 2026.

Battery current POLESTAR_BAT_CURRENT

  • Request22 40 90
  • Service 22DID 4090
  • ModuleD01A → 1F402E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 512)
Range
-512 to 3583 A
Unit
A

In testing for 2024 to 2026.

Battery heater on POLESTAR_ED_HEATER_ON

  • Request22 D3 02
  • Service 22DID D302
  • Module7E5 → 7ED
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2024 to 2026.

Battery module 1 temperature POLESTAR_ED_MOD_T1

  • Request22 02 02
  • Service 22DID 0202
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 64)
Range
-512 to 511.9843 °C
Unit
°C

In testing for 2024 to 2026.

Battery module 2 temperature POLESTAR_ED_MOD_T2

  • Request22 02 02
  • Service 22DID 0202
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 64)
Range
-512 to 511.9843 °C
Unit
°C

In testing for 2024 to 2026.

Battery module 3 temperature POLESTAR_ED_MOD_T3

  • Request22 02 02
  • Service 22DID 0202
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 64)
Range
-512 to 511.9843 °C
Unit
°C

In testing for 2024 to 2026.

Battery module 4 temperature POLESTAR_ED_MOD_T4

  • Request22 02 02
  • Service 22DID 0202
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 64)
Range
-512 to 511.9843 °C
Unit
°C

In testing for 2024 to 2026.

Battery module 5 temperature POLESTAR_ED_MOD_T5

  • Request22 02 02
  • Service 22DID 0202
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 64)
Range
-512 to 511.9843 °C
Unit
°C

In testing for 2024 to 2026.

Battery module 6 temperature POLESTAR_ED_MOD_T6

  • Request22 02 02
  • Service 22DID 0202
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 64)
Range
-512 to 511.9843 °C
Unit
°C

In testing for 2024 to 2026.

Battery module 7 temperature POLESTAR_ED_MOD_T7

  • Request22 02 02
  • Service 22DID 0202
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 96 to 111 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 64)
Range
-512 to 511.9843 °C
Unit
°C

In testing for 2024 to 2026.

Battery module 8 temperature POLESTAR_ED_MOD_T8

  • Request22 02 02
  • Service 22DID 0202
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 112 to 127 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 64)
Range
-512 to 511.9843 °C
Unit
°C

In testing for 2024 to 2026.

Battery module 9 temperature POLESTAR_ED_MOD_T9

  • Request22 02 02
  • Service 22DID 0202
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 128 to 143 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 64)
Range
-512 to 511.9843 °C
Unit
°C

In testing for 2024 to 2026.

Battery operating mode POLESTAR_EV_MODE

  • Request21 07
  • Service 21PID 07
  • Module79B → 7BB
  • Every5 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val
Range
0 to 7
Unit
Number

In testing for 2024 to 2026.

Battery operation time since battery monitoring sensor reset, days POLESTAR_BAT_OPERATION_TIME

  • Request22 40 27
  • Service 22DID 4027
  • Module726
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2024 to 2026.

Battery relay POLESTAR_BAT_RELAY

  • Request22 D9 53
  • Service 22DID D953
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Battery state of charge POLESTAR_BAT_ST_CHG

  • Request22 40 28
  • Service 22DID 4028
  • ModuleD01A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 %
Unit
%

In testing for 2024 to 2026.

Battery state of charge POLESTAR_BAT_ST_CHG_726

  • Request22 40 28
  • Service 22DID 4028
  • Module726
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2024 to 2026.

Battery temperature POLESTAR_BAT_T

  • Request22 40 29
  • Service 22DID 4029
  • Module726
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2024 to 2026.

Battery voltage POLESTAR_BAT_V

  • Request22 40 CD
  • Service 22DID 40CD
  • ModuleD01A → 1F402E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 40 + 5)
Range
0 to 1643 V
Unit
V

In testing for 2024 to 2026.

Battery voltage POLESTAR_BAT_V_726

Pelican can show this parameter as the starter battery voltage.

  • Request22 40 2A
  • Service 22DID 402A
  • Module726
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 20 + 6)
Range
0 to 18.75 V
Unit
V

In testing for 2024 to 2026.

Boost pressure after turbocharger POLESTAR_BOOST_P_AFTER

  • Request22 03 3E
  • Service 22DID 033E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 131 − 0.053435)
Range
-0.0534 to 500 kPa
Unit
kPa

In testing for 2024 to 2026.

Capacity loss POLESTAR_CAP_LOSS

  • Request21 08
  • Service 21PID 08
  • Module79B → 7BB
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val ÷ 16)
Range
0 to 4095.9375 %
Unit
%

In testing for 2024 to 2026.

Cell capacity, average POLESTAR_ED_CAP_AS_AVG

  • Request22 03 10
  • Service 22DID 0310
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 152 to 167 of the reply, 16 bits.

Formula
(val ÷ 3600)
Range
0 to 18.2041 Ah
Unit
Ah

In testing for 2024 to 2026.

Cell capacity, maximum POLESTAR_ED_CAP_AS_MAX

  • Request22 03 10
  • Service 22DID 0310
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
(val ÷ 3600)
Range
0 to 18.2041 Ah
Unit
Ah

In testing for 2024 to 2026.

Cell capacity, minimum POLESTAR_ED_CAP_AS_MIN

  • Request22 03 10
  • Service 22DID 0310
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 136 to 151 of the reply, 16 bits.

Formula
(val ÷ 3600)
Range
0 to 18.2041 Ah
Unit
Ah

In testing for 2024 to 2026.

Cell voltage reference, average POLESTAR_ED_ADC_V_AVG

  • Request22 02 07
  • Service 22DID 0207
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mV
Unit
mV

In testing for 2024 to 2026.

Cell voltage reference, maximum POLESTAR_ED_ADC_V_MAX

  • Request22 02 07
  • Service 22DID 0207
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val + 1500)
Range
1500 to 67035 mV
Unit
mV

In testing for 2024 to 2026.

Cell voltage reference, minimum POLESTAR_ED_ADC_V_MIN

  • Request22 02 07
  • Service 22DID 0207
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val + 1500)
Range
1500 to 67035 mV
Unit
mV

In testing for 2024 to 2026.

Charge air pressure POLESTAR_CHG_AIR_P

  • Request22 EE 3E
  • Service 22DID EE3E
  • ModuleD016 → 1EC60E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.007812)
Range
0 to 511 kPa
Unit
kPa

In testing for 2024 to 2026.

Charge power limit POLESTAR_CHG_POWER_LIM

  • Request22 48 9C
  • Service 22DID 489C
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
(val × 4 ÷ 15625)
Range
0 to 4294 kW
Unit
kW

In testing for 2024 to 2026.

Charger 12V output voltage POLESTAR_ED_OBL_LV

  • Request22 02 26
  • Service 22DID 0226
  • Module61A → 483
  • Every10 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 V
Unit
V

In testing for 2024 to 2026.

Charger cable selected current POLESTAR_CHARGER_CABLE

  • Request22 EE 8D
  • Service 22DID EE8D
  • ModuleD016 → 1EC68E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 410)
Range
-410 to 6143 A
Unit
A

In testing for 2024 to 2026.

Charger cooling plate temperature POLESTAR_ED_OBL_PLATE_T

  • Request22 02 23
  • Service 22DID 0223
  • Module61A → 483
  • Every60 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2024 to 2026.

Charger current set point POLESTAR_ED_OBL_A_SET

  • Request22 02 2A
  • Service 22DID 022A
  • Module61A → 483
  • Every60 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255 A
Unit
A

In testing for 2024 to 2026.

Charger HV output current POLESTAR_ED_OBL_HV_A

  • Request22 02 25
  • Service 22DID 0225
  • Module61A → 483
  • Every10 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 204.7 A
Unit
A

In testing for 2024 to 2026.

Charger HV output voltage POLESTAR_ED_OBL_HV

  • Request22 02 26
  • Service 22DID 0226
  • Module61A → 483
  • Every10 s
  • Testing

Bits 40 to 55 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 819 V
Unit
V

In testing for 2024 to 2026.

Charger mains current POLESTAR_ED_OBL_MAINS_A

  • Request22 02 25
  • Service 22DID 0225
  • Module61A → 483
  • Every10 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 204.7 A
Unit
A

In testing for 2024 to 2026.

Charger mains current, phase 1 POLESTAR_OBL_A1

  • Request22 73 03
  • Service 22DID 7303
  • Module792 → 793
  • Every10 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 5990.4 A
Unit
A

In testing for 2024 to 2026.

Charger mains current, phase 2 POLESTAR_OBL_A2

  • Request22 73 03
  • Service 22DID 7303
  • Module792 → 793
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 5990.4 A
Unit
A

In testing for 2024 to 2026.

Charger mains voltage POLESTAR_ED_OBL_MAINS_V

  • Request22 02 26
  • Service 22DID 0226
  • Module61A → 483
  • Every10 s
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 819 V
Unit
V

In testing for 2024 to 2026.

Charger mains voltage POLESTAR_OBL_V

  • Request22 73 03
  • Service 22DID 7303
  • Module792 → 793
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 5990.4 V
Unit
V

In testing for 2024 to 2026.

Charger power 1 POLESTAR_OBL_P1

  • Request22 73 03
  • Service 22DID 7303
  • Module792 → 793
  • Every10 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
(val ÷ 2000)
Range
0 to 29.952 kW
Unit
kW

In testing for 2024 to 2026.

Charger power 2 POLESTAR_OBL_P2

  • Request22 73 03
  • Service 22DID 7303
  • Module792 → 793
  • Every10 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
(val ÷ 2000)
Range
0 to 29.952 kW
Unit
kW

In testing for 2024 to 2026.

Charger temperature POLESTAR_ED_OBL_T

  • Request22 02 23
  • Service 22DID 0223
  • Module61A → 483
  • Every60 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2024 to 2026.

Charging cable current code POLESTAR_ED_OBL_CABLE_A

  • Request22 02 25
  • Service 22DID 0225
  • Module61A → 483
  • Every10 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553.5 A
Unit
A

In testing for 2024 to 2026.

Charging plug detected POLESTAR_PLUG

Pelican can show this parameter as the plug state.

  • Request22 33 9D
  • Service 22DID 339D
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 4 to 7 of the reply, 4 bits.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2024 to 2026.

Charging socket temperature POLESTAR_ED_OBL_SOCKET_T

  • Request22 02 23
  • Service 22DID 0223
  • Module61A → 483
  • Every60 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2024 to 2026.

Charging socket, locked POLESTAR_CHG_SOCKET_LOCKED

  • Request22 EE 8C
  • Service 22DID EE8C
  • ModuleD016 → 1EC68E80
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Control module supply voltage POLESTAR_ENG_CTRL_MODULE_SUP_V

  • Request22 F4 42
  • Service 22DID F442
  • ModuleD016 → 1EC6AE80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.53 V
Unit
V

In testing for 2024 to 2026.

Control module voltage POLESTAR_CTRL_MODULE_V_MS_CAN

  • Request22 D9 04
  • Service 22DID D904
  • Module784
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 V
Unit
V

In testing for 2024 to 2026.

DC charger current POLESTAR_DC_CHARGER_CURRENT

  • Request22 EE 16
  • Service 22DID EE16
  • ModuleD016 → 1EC68E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 A
Unit
A

In testing for 2024 to 2026.

DC charger voltage POLESTAR_DC_CHARGER_V

  • Request22 EE 17
  • Service 22DID EE17
  • ModuleD016 → 1EC68E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 V
Unit
V

In testing for 2024 to 2026.

DC converter requested voltage POLESTAR_EQA_CNVRTR_REQ_V

  • Request22 60 71
  • Service 22DID 6071
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 250 ÷ 10000)
Range
0 to 100 V
Unit
V

In testing for 2024 to 2026.

Discharge power limit POLESTAR_DCHG_POWER_LIM

  • Request22 48 9E
  • Service 22DID 489E
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
(val × 4 ÷ 15625)
Range
0 to 4294 kW
Unit
kW

In testing for 2024 to 2026.

Estimated capacity POLESTAR_CAP_EST

  • Request21 08
  • Service 21PID 08
  • Module79B → 7BB
  • Every10 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
(val ÷ 360)
Range
0 to 182.0416 Ah
Unit
Ah

In testing for 2024 to 2026.

External temperature sensor, HV battery cooling module POLESTAR_EXTERNAL_T_SENS

  • Request22 EE 46
  • Service 22DID EE46
  • ModuleD016 → 1EC60E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.14)
Range
-273 to 6280 °C
Unit
°C

In testing for 2024 to 2026.

Front camera voltage supply POLESTAR_FRONT_CAMERA_V_SUP

  • Request22 99 69
  • Service 22DID 9969
  • Module764
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 2 ÷ 25)
Range
0 to 20.4 V
Unit
V

In testing for 2024 to 2026.

Fuse DC charging voltage POLESTAR_FUSE_DC_CHG_V

  • Request22 49 8B
  • Service 22DID 498B
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 V
Unit
V

In testing for 2024 to 2026.

High voltage battery - voltage at IEM fuse POLESTAR_HVBAT_V_IEM_FUSE

  • Request22 48 59
  • Service 22DID 4859
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 V
Unit
V

In testing for 2024 to 2026.

High voltage battery - voltage at IHFA fuse POLESTAR_HVBAT_V_IHFA_FUSE

  • Request22 48 58
  • Service 22DID 4858
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 V
Unit
V

In testing for 2024 to 2026.

High voltage battery cell voltage sum POLESTAR_HVBAT_CELL_VOLTAGES

  • Request22 49 7C
  • Service 22DID 497C
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 V
Unit
V

In testing for 2024 to 2026.

High voltage battery contactor voltage POLESTAR_HVBAT_CONTACTOR_V

  • Request22 48 57
  • Service 22DID 4857
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 V
Unit
V

In testing for 2024 to 2026.

High voltage battery coolant inlet temperature POLESTAR_HVBAT_CLT_INLET_T

  • Request22 48 04
  • Service 22DID 4804
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 °C
Unit
°C

In testing for 2024 to 2026.

High voltage battery coolant outlet temperature POLESTAR_HVBAT_CLT_OUTLET_T

  • Request22 49 90
  • Service 22DID 4990
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 °C
Unit
°C

In testing for 2024 to 2026.

High voltage battery current POLESTAR_HVBAT_CURRENT

Pelican can show this parameter as the traction battery current.

  • Request22 48 02
  • Service 22DID 4802
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 A
Unit
A

In testing for 2024 to 2026.

High voltage battery negative contactor voltage POLESTAR_HVBAT_NEGATIVE_V

  • Request22 4A 58
  • Service 22DID 4A58
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 V
Unit
V

In testing for 2024 to 2026.

High voltage battery state of charge POLESTAR_HVBAT_ST_CHG

Pelican can show this parameter as the state of charge.

  • Request22 48 01
  • Service 22DID 4801
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 500)
Range
0 to 131 %
Unit
%

In testing for 2024 to 2026.

High voltage battery state of health POLESTAR_HVBAT_ST_HEALTH

Pelican can show this parameter as the state of health.

  • Request22 49 6D
  • Service 22DID 496D
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 100)
Range
0 to 42949672 %
Unit
%

In testing for 2024 to 2026.

High voltage battery voltage POLESTAR_HVBAT_V

Pelican can show this parameter as the traction battery voltage.

  • Request22 48 03
  • Service 22DID 4803
  • ModuleD016 → 1EC6AE80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 2024 to 2026.

High voltage battery, average temperature POLESTAR_HVBAT_AVG_T

  • Request22 49 1B
  • Service 22DID 491B
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100 − 50)
Range
-50 to 605 °C
Unit
°C

In testing for 2024 to 2026.

High voltage battery, coolant pump speed, actual POLESTAR_HVBAT_CLT_PMP_SPD_ACT

  • Request22 48 67
  • Service 22DID 4867
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 24)
Range
0 to 6120 rpm
Unit
rpm

In testing for 2024 to 2026.

High voltage battery, coolant pump speed, requested POLESTAR_HVBAT_CLT_PMP_SPD

  • Request22 48 66
  • Service 22DID 4866
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 24)
Range
0 to 6120 rpm
Unit
rpm

In testing for 2024 to 2026.

High voltage battery, high-voltage coolant heater fuse voltage POLESTAR_HVBAT_HVCH_FUSE_V

  • Request22 48 0A
  • Service 22DID 480A
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 V
Unit
V

In testing for 2024 to 2026.

High voltage battery, IEM fuse voltage POLESTAR_HVBAT_IEM_FUSE_V

  • Request22 48 08
  • Service 22DID 4808
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 V
Unit
V

In testing for 2024 to 2026.

High voltage battery, IGM fuse voltage POLESTAR_HVBAT_IGM_FUSE_V

  • Request22 48 09
  • Service 22DID 4809
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 V
Unit
V

In testing for 2024 to 2026.

High voltage battery, inlet coolant temperature POLESTAR_HVBAT_INLET_ECT

  • Request22 48 04
  • Service 22DID 4804
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2024 to 2026.

High voltage battery, max temperature POLESTAR_HVBAT_MAX_T

  • Request22 49 45
  • Service 22DID 4945
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
(val ÷ 100 − 50)
Range
-50 to 605 °C
Unit
°C

In testing for 2024 to 2026.

High voltage battery, OBC fuse voltage POLESTAR_HVBAT_OBC_FUSE_V

  • Request22 48 0B
  • Service 22DID 480B
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 V
Unit
V

In testing for 2024 to 2026.

High voltage system voltage POLESTAR_HIGH_V_SYSTEM_V

  • Request22 98 5C
  • Service 22DID 985C
  • ModuleD016 → 1EC6EE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383 V
Unit
V

In testing for 2024 to 2026.

High voltage system voltage POLESTAR_HIGH_V_SYSTEM_V_D016

  • Request22 98 5C
  • Service 22DID 985C
  • ModuleD016 → 1ED24E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383 V
Unit
V

In testing for 2024 to 2026.

Highest cell voltage POLESTAR_CELL_V_MAX

  • Request21 07
  • Service 21PID 07
  • Module79B → 7BB
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

HV battery amperage POLESTAR_EQA_HV_A

  • Request22 60 53
  • Service 22DID 6053
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
0 to 100 A
Unit
A

In testing for 2024 to 2026.

HV battery available energy POLESTAR_HV_E

  • Request22 32 0C
  • Service 22DID 320C
  • Module7E4 → 7EC
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 200)
Range
0 to 327.675 kWh
Unit
kWh

In testing for 2024 to 2026.

HV battery coolant temperature POLESTAR_EQA_HV_COOLANT_T

  • Request22 25 26
  • Service 22DID 2526
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 1250 ÷ 10000)
Range
0 to 100 °C
Unit
°C

In testing for 2024 to 2026.

HV battery current POLESTAR_ED_HV_A

  • Request22 02 03
  • Service 22DID 0203
  • Module7E7 → 7EF
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 32)
Range
-1024 to 1023.9687 A
Unit
A

In testing for 2024 to 2026.

HV battery current POLESTAR_HV_A

Pelican can show this parameter as the traction battery current.

  • Request21 07
  • Service 21PID 07
  • Module79B → 7BB
  • Every5 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The value is signed.

Formula
(val × -1 ÷ 32)
Range
-1023.9687 to 1024 A
Unit
A

In testing for 2024 to 2026.

HV battery open-circuit voltage POLESTAR_OCV

  • Request21 08
  • Service 21PID 08
  • Module79B → 7BB
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 V
Unit
V

In testing for 2024 to 2026.

HV battery state of charge POLESTAR_EQA_HV_SOC

Pelican can show this parameter as the state of charge.

  • Request22 60 50
  • Service 22DID 6050
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

In testing for 2024 to 2026.

HV battery temperature POLESTAR_ED_HV_T

  • Request22 02 01
  • Service 22DID 0201
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 64)
Range
-512 to 511.9843 °C
Unit
°C

In testing for 2024 to 2026.

HV battery temperature, average POLESTAR_HV_T_AVG

  • Request21 04
  • Service 21PID 04
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 64)
Range
-512 to 511.9843 °C
Unit
°C

In testing for 2024 to 2026.

HV battery temperature, maximum POLESTAR_HV_T_MAX

  • Request21 04
  • Service 21PID 04
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 64)
Range
-512 to 511.9843 °C
Unit
°C

In testing for 2024 to 2026.

HV battery temperature, minimum POLESTAR_HV_T_MIN

  • Request21 04
  • Service 21PID 04
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 64)
Range
-512 to 511.9843 °C
Unit
°C

In testing for 2024 to 2026.

HV battery voltage POLESTAR_ED_HV_V

  • Request22 02 04
  • Service 22DID 0204
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val ÷ 64)
Range
0 to 1023.9843 V
Unit
V

In testing for 2024 to 2026.

HV battery voltage POLESTAR_EQA_HV_V

  • Request22 60 75
  • Service 22DID 6075
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 25 ÷ 1000)
Range
0 to 100 V
Unit
V

In testing for 2024 to 2026.

HV battery voltage POLESTAR_HV_V

Pelican can show this parameter as the traction battery voltage.

  • Request21 07
  • Service 21PID 07
  • Module79B → 7BB
  • Every5 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val ÷ 64)
Range
0 to 1023.9843 V
Unit
V

In testing for 2024 to 2026.

HV contactor cycles remaining POLESTAR_ED_CONT_LEFT

  • Request22 03 0B
  • Service 22DID 030B
  • Module7E7 → 7EF
  • Every600 s
  • Testing

Bits 8 to 31 of the reply, 24 bits.

Formula
val
Range
0 to 16777215
Unit
Number

In testing for 2024 to 2026.

HV contactor cycles remaining POLESTAR_HV_CONT_LEFT

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2024 to 2026.

HV contactor cycles, maximum POLESTAR_ED_CONT_MAX

  • Request22 03 0C
  • Service 22DID 030C
  • Module7E7 → 7EF
  • Every600 s
  • Testing

Bits 8 to 31 of the reply, 24 bits.

Formula
val
Range
0 to 16777215
Unit
Number

In testing for 2024 to 2026.

HV contactor cycles, maximum POLESTAR_HV_CONT_MAX

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 32 to 63 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2024 to 2026.

HV contactor state POLESTAR_ED_CONTACTOR

  • Request22 D0 00
  • Service 22DID D000
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

HV contactor state POLESTAR_HV_CONTACTOR

  • Request21 07
  • Service 21PID 07
  • Module79B → 7BB
  • Every5 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 3
Unit
Number

In testing for 2024 to 2026.

HV DC fault code POLESTAR_ED_DC_FAULT

  • Request22 02 09
  • Service 22DID 0209
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

HV isolation resistance POLESTAR_ED_ISO

  • Request22 02 09
  • Service 22DID 0209
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65534 kΩ
Unit
kΩ

In testing for 2024 to 2026.

HV plug interlock closed POLESTAR_HV_INTERLOCK_PLUG

  • Request21 07
  • Service 21PID 07
  • Module79B → 7BB
  • Every5 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2024 to 2026.

Initial capacity POLESTAR_CAP_INIT

  • Request21 08
  • Service 21PID 08
  • Module79B → 7BB
  • Every10 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
(val ÷ 360)
Range
0 to 182.0416 Ah
Unit
Ah

In testing for 2024 to 2026.

Leakage current, 10 kilohertz POLESTAR_LEAK_HF10

  • Request22 50 66
  • Service 22DID 5066
  • Module792 → 793
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 − 32.768)
Range
-32.768 to 32.7669
Unit
Number

In testing for 2024 to 2026.

Leakage DC current POLESTAR_LEAK_DC

  • Request22 50 65
  • Service 22DID 5065
  • Module792 → 793
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 − 32.768)
Range
-32.768 to 32.7669
Unit
Number

In testing for 2024 to 2026.

Leakage diagnostic code POLESTAR_LEAK_DIAG

  • Request22 50 64
  • Service 22DID 5064
  • Module792 → 793
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Leakage high-frequency current POLESTAR_LEAK_HF

  • Request22 50 67
  • Service 22DID 5067
  • Module792 → 793
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 − 32.768)
Range
-32.768 to 32.7669
Unit
Number

In testing for 2024 to 2026.

Leakage low-frequency current POLESTAR_LEAK_LF

  • Request22 50 68
  • Service 22DID 5068
  • Module792 → 793
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 − 32.768)
Range
-32.768 to 32.7669
Unit
Number

In testing for 2024 to 2026.

Lowest cell voltage POLESTAR_CELL_V_MIN

  • Request21 07
  • Service 21PID 07
  • Module79B → 7BB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Main charger current POLESTAR_MAIN_CHARGER_CURRENT

  • Request22 EE 15
  • Service 22DID EE15
  • ModuleD016 → 1EC68E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 A
Unit
A

In testing for 2024 to 2026.

Main charger voltage POLESTAR_MAIN_CHARGER_V

  • Request22 EE 1C
  • Service 22DID EE1C
  • ModuleD016 → 1EC68E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 2024 to 2026.

Mains active power POLESTAR_MAINS_P

  • Request22 50 4A
  • Service 22DID 504A
  • Module792 → 793
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 − 20)
Range
-20 to 45.5349 kW
Unit
kW

In testing for 2024 to 2026.

Mains current limit POLESTAR_MAINS_A_LIMIT

  • Request22 50 70
  • Service 22DID 5070
  • Module792 → 793
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 − 32.768)
Range
-32.768 to 32.7669
Unit
Number

In testing for 2024 to 2026.

Mains current, phase 2 POLESTAR_MAINS_A_2

  • Request22 50 3A
  • Service 22DID 503A
  • Module792 → 793
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 200)
Range
-200 to 3895.9375 A
Unit
A

In testing for 2024 to 2026.

Mains current, phase 3 POLESTAR_MAINS_A_3

  • Request22 50 3B
  • Service 22DID 503B
  • Module792 → 793
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 200)
Range
-200 to 3895.9375 A
Unit
A

In testing for 2024 to 2026.

Mains frequency POLESTAR_MAINS_HZ

  • Request22 50 49
  • Service 22DID 5049
  • Module792 → 793
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 128 + 10)
Range
10 to 521.9921 Hz
Unit
Hz

In testing for 2024 to 2026.

Mains ground resistance POLESTAR_MAINS_GND_R

  • Request22 50 62
  • Service 22DID 5062
  • Module792 → 793
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 − 32.768)
Range
-32.768 to 32.7669
Unit
Number

In testing for 2024 to 2026.

Mains voltage, phases 1-2 POLESTAR_MAINS_V_12

  • Request22 50 3F
  • Service 22DID 503F
  • Module792 → 793
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2)
Range
0 to 32767.5 V
Unit
V

In testing for 2024 to 2026.

Mains voltage, phases 2-3 POLESTAR_MAINS_V_23

  • Request22 50 41
  • Service 22DID 5041
  • Module792 → 793
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2)
Range
0 to 32767.5 V
Unit
V

In testing for 2024 to 2026.

Mains voltage, phases 3-1 POLESTAR_MAINS_V_31

  • Request22 50 42
  • Service 22DID 5042
  • Module792 → 793
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2)
Range
0 to 32767.5 V
Unit
V

In testing for 2024 to 2026.

Module voltage POLESTAR_MODULE_V

  • Request22 D1 11
  • Service 22DID D111
  • ModuleD016 → 1EC70E80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 V
Unit
V

In testing for 2024 to 2026.

Open-circuit voltage state POLESTAR_OCV_STATE

  • Request21 08
  • Service 21PID 08
  • Module79B → 7BB
  • Every10 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val
Range
0 to 4
Unit
Number

In testing for 2024 to 2026.

Real state of charge, maximum POLESTAR_SOC_REAL_MAX

  • Request21 08
  • Service 21PID 08
  • Module79B → 7BB
  • Every10 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val ÷ 16)
Range
0 to 4095.9375 %
Unit
%

In testing for 2024 to 2026.

Real state of charge, minimum POLESTAR_SOC_REAL_MIN

  • Request21 08
  • Service 21PID 08
  • Module79B → 7BB
  • Every10 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 16)
Range
0 to 4095.9375 %
Unit
%

In testing for 2024 to 2026.

Secondary battery charge time POLESTAR_SECONDARY_BAT_CHG

  • Request22 EE D3
  • Service 22DID EED3
  • Module726
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

In testing for 2024 to 2026.

Secondary battery needed charge time POLESTAR_SECONDARY_BAT_NEEDED

  • Request22 EE D5
  • Service 22DID EED5
  • Module726
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

In testing for 2024 to 2026.

Secondary battery relay POLESTAR_SECONDARY_BAT_RELAY

  • Request22 41 9C
  • Service 22DID 419C
  • Module726
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Secondary battery temperature POLESTAR_SECONDARY_BAT_T_25_C

  • Request22 EE D2
  • Service 22DID EED2
  • Module726
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2024 to 2026.

Secondary battery voltage POLESTAR_SECONDARY_BAT_V

  • Request22 41 7E
  • Service 22DID 417E
  • Module726
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 V
Unit
V

In testing for 2024 to 2026.

Secondary battery voltage average value POLESTAR_SECONDARY_BAT_V_AVG

  • Request22 EE D7
  • Service 22DID EED7
  • Module726
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 V
Unit
V

In testing for 2024 to 2026.

Secondary battery voltage latest stored POLESTAR_SECONDARY_BAT_V_LATEST

  • Request22 EE D4
  • Service 22DID EED4
  • Module726
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 V
Unit
V

In testing for 2024 to 2026.

Service interlock closed POLESTAR_HV_INTERLOCK_SVC

  • Request21 07
  • Service 21PID 07
  • Module79B → 7BB
  • Every5 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2024 to 2026.

Servo supply voltage POLESTAR_SERVO_SUP_V

  • Request22 41 3D
  • Service 22DID 413D
  • Module730
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 V
Unit
V

In testing for 2024 to 2026.

Start/stop battery relay POLESTAR_START_STOP_BAT_RELAY

  • Request22 EF 51
  • Service 22DID EF51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Start/stop secondary battery relay POLESTAR_START_STOP_SECONDARY

  • Request22 EF 52
  • Service 22DID EF52
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

State of charge POLESTAR_SOC

  • Request22 40 28
  • Service 22DID 4028
  • ModuleD01A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 100 %
Unit
%

In testing for 2024, 2026. Not supported for 2025.

State of charge POLESTAR_SOC_V2

Pelican can show this parameter as the state of charge.

  • Request21 08
  • Service 21PID 08
  • Module79B → 7BB
  • Every10 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val ÷ 16)
Range
0 to 4095.9375 %
Unit
%

In testing for 2024 to 2026.

State of charge recalibration state POLESTAR_SOC_RECAL

  • Request21 25
  • Service 21PID 25
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 3
Unit
Number

In testing for 2024 to 2026.

State of charge, displayed POLESTAR_SOC_DISPLAY

  • Request21 25
  • Service 21PID 25
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
(val ÷ 16)
Range
0 to 4095.9375 %
Unit
%

In testing for 2024 to 2026.

State of health POLESTAR_SOH

Pelican can show this parameter as the state of health.

  • Request21 61
  • Service 21PID 61
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127.5 %
Unit
%

In testing for 2024 to 2026.

State of health, raw POLESTAR_ED_SOH

  • Request22 03 10
  • Service 22DID 0310
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Sum of cell voltages POLESTAR_HV_CELL_SUM_V

  • Request21 07
  • Service 21PID 07
  • Module79B → 7BB
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val ÷ 64)
Range
0 to 1023.9843 V
Unit
V

In testing for 2024 to 2026.

Supercharger clutch, requested position POLESTAR_SUPERCHARGER_CLU_REQ

  • Request22 EE 84
  • Service 22DID EE84
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Time with HV off POLESTAR_ED_HV_OFF_TIME

  • Request22 03 10
  • Service 22DID 0310
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 8 to 31 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 s
Unit
s

In testing for 2024 to 2026.

Transmission control module supply voltage POLESTAR_MECU_SUP_V

  • Request22 DD 02
  • Service 22DID DD02
  • Module7E1
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 4)
Range
0 to 63.75 V
Unit
V

In testing for 2024 to 2026.

Usable capacity, full POLESTAR_CAP_FULL

  • Request21 61
  • Service 21PID 61
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 360)
Range
-91.0222 to 91.0194 Ah
Unit
Ah

In testing for 2024 to 2026.

Voltage supply POLESTAR_V_SUP

  • Request22 D9 01
  • Service 22DID D901
  • Module737
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 2 ÷ 25)
Range
0 to 20.4 V
Unit
V

In testing for 2024 to 2026.

Voltage supply POLESTAR_V_SUP_764

  • Request22 D1 12
  • Service 22DID D112
  • Module764
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 2 ÷ 25)
Range
0 to 20.4 V
Unit
V

In testing for 2024 to 2026.

Voltage supply POLESTAR_V_SUP_MS_CAN

  • Request22 D1 11
  • Service 22DID D111
  • Module791
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 V
Unit
V

In testing for 2024 to 2026.

Voltage/power sensitive loads connected POLESTAR_V_POWER_SENSITIVE

  • Request22 EE A2
  • Service 22DID EEA2
  • Module726
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Battery › Cells

Cell 1 voltage POLESTAR_CELL_V1

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 1 voltage POLESTAR_ED_CELL_V1

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 2 voltage POLESTAR_CELL_V2

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 2 voltage POLESTAR_ED_CELL_V2

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 3 voltage POLESTAR_CELL_V3

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 3 voltage POLESTAR_ED_CELL_V3

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 4 voltage POLESTAR_CELL_V4

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 4 voltage POLESTAR_ED_CELL_V4

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 5 voltage POLESTAR_CELL_V5

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 5 voltage POLESTAR_ED_CELL_V5

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 6 voltage POLESTAR_CELL_V6

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 6 voltage POLESTAR_ED_CELL_V6

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 7 voltage POLESTAR_CELL_V7

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 7 voltage POLESTAR_ED_CELL_V7

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 8 voltage POLESTAR_CELL_V8

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 8 voltage POLESTAR_ED_CELL_V8

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 9 voltage POLESTAR_CELL_V9

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 9 voltage POLESTAR_ED_CELL_V9

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 10 voltage POLESTAR_CELL_V10

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 144 to 159 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 10 voltage POLESTAR_ED_CELL_V10

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 144 to 159 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 11 voltage POLESTAR_CELL_V11

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 160 to 175 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 11 voltage POLESTAR_ED_CELL_V11

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 160 to 175 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 12 voltage POLESTAR_CELL_V12

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 12 voltage POLESTAR_ED_CELL_V12

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 13 voltage POLESTAR_CELL_V13

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 13 voltage POLESTAR_ED_CELL_V13

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 14 voltage POLESTAR_CELL_V14

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 14 voltage POLESTAR_ED_CELL_V14

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 15 voltage POLESTAR_CELL_V15

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 15 voltage POLESTAR_ED_CELL_V15

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 16 voltage POLESTAR_CELL_V16

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 240 to 255 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 16 voltage POLESTAR_ED_CELL_V16

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 240 to 255 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 17 voltage POLESTAR_CELL_V17

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 256 to 271 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 17 voltage POLESTAR_ED_CELL_V17

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 256 to 271 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 18 voltage POLESTAR_CELL_V18

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 18 voltage POLESTAR_ED_CELL_V18

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 19 voltage POLESTAR_CELL_V19

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 19 voltage POLESTAR_ED_CELL_V19

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 20 voltage POLESTAR_CELL_V20

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 304 to 319 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 20 voltage POLESTAR_ED_CELL_V20

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 304 to 319 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 21 voltage POLESTAR_CELL_V21

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 320 to 335 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 21 voltage POLESTAR_ED_CELL_V21

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 320 to 335 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 22 voltage POLESTAR_CELL_V22

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 336 to 351 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 22 voltage POLESTAR_ED_CELL_V22

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 336 to 351 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 23 voltage POLESTAR_CELL_V23

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 352 to 367 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 23 voltage POLESTAR_ED_CELL_V23

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 352 to 367 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 24 voltage POLESTAR_CELL_V24

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 368 to 383 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 24 voltage POLESTAR_ED_CELL_V24

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 368 to 383 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 25 voltage POLESTAR_CELL_V25

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 384 to 399 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 25 voltage POLESTAR_ED_CELL_V25

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 384 to 399 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 26 voltage POLESTAR_CELL_V26

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 400 to 415 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 26 voltage POLESTAR_ED_CELL_V26

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 400 to 415 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 27 voltage POLESTAR_CELL_V27

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 416 to 431 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 27 voltage POLESTAR_ED_CELL_V27

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 416 to 431 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 28 voltage POLESTAR_CELL_V28

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 432 to 447 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 28 voltage POLESTAR_ED_CELL_V28

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 432 to 447 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 29 voltage POLESTAR_CELL_V29

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 448 to 463 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 29 voltage POLESTAR_ED_CELL_V29

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 448 to 463 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 30 voltage POLESTAR_CELL_V30

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 464 to 479 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 30 voltage POLESTAR_ED_CELL_V30

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 464 to 479 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 31 voltage POLESTAR_CELL_V31

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 480 to 495 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 31 voltage POLESTAR_ED_CELL_V31

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 480 to 495 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 32 voltage POLESTAR_CELL_V32

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 496 to 511 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 32 voltage POLESTAR_ED_CELL_V32

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 496 to 511 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 33 voltage POLESTAR_CELL_V33

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 512 to 527 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 33 voltage POLESTAR_ED_CELL_V33

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 512 to 527 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 34 voltage POLESTAR_CELL_V34

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 528 to 543 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 34 voltage POLESTAR_ED_CELL_V34

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 528 to 543 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 35 voltage POLESTAR_CELL_V35

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 544 to 559 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 35 voltage POLESTAR_ED_CELL_V35

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 544 to 559 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 36 voltage POLESTAR_CELL_V36

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 560 to 575 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 36 voltage POLESTAR_ED_CELL_V36

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 560 to 575 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 37 voltage POLESTAR_CELL_V37

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 576 to 591 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 37 voltage POLESTAR_ED_CELL_V37

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 576 to 591 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 38 voltage POLESTAR_CELL_V38

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 592 to 607 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 38 voltage POLESTAR_ED_CELL_V38

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 592 to 607 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 39 voltage POLESTAR_CELL_V39

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 608 to 623 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 39 voltage POLESTAR_ED_CELL_V39

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 608 to 623 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 40 voltage POLESTAR_CELL_V40

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 624 to 639 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 40 voltage POLESTAR_ED_CELL_V40

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 624 to 639 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 41 voltage POLESTAR_CELL_V41

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 640 to 655 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 41 voltage POLESTAR_ED_CELL_V41

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 640 to 655 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 42 voltage POLESTAR_CELL_V42

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 656 to 671 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 42 voltage POLESTAR_ED_CELL_V42

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 656 to 671 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 43 voltage POLESTAR_CELL_V43

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 672 to 687 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 43 voltage POLESTAR_ED_CELL_V43

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 672 to 687 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 44 voltage POLESTAR_CELL_V44

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 688 to 703 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 44 voltage POLESTAR_ED_CELL_V44

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 688 to 703 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 45 voltage POLESTAR_CELL_V45

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 704 to 719 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 45 voltage POLESTAR_ED_CELL_V45

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 704 to 719 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 46 voltage POLESTAR_CELL_V46

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 720 to 735 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 46 voltage POLESTAR_ED_CELL_V46

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 720 to 735 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 47 voltage POLESTAR_CELL_V47

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 736 to 751 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 47 voltage POLESTAR_ED_CELL_V47

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 736 to 751 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 48 voltage POLESTAR_CELL_V48

  • Request21 41
  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 752 to 767 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 48 voltage POLESTAR_ED_CELL_V48

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 752 to 767 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 49 voltage POLESTAR_CELL_V49

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 49 voltage POLESTAR_ED_CELL_V49

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 768 to 783 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 50 voltage POLESTAR_CELL_V50

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 50 voltage POLESTAR_ED_CELL_V50

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 784 to 799 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 51 voltage POLESTAR_CELL_V51

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 51 voltage POLESTAR_ED_CELL_V51

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 800 to 815 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 52 voltage POLESTAR_CELL_V52

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 52 voltage POLESTAR_ED_CELL_V52

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 816 to 831 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 53 voltage POLESTAR_CELL_V53

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 53 voltage POLESTAR_ED_CELL_V53

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 832 to 847 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 54 voltage POLESTAR_CELL_V54

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 54 voltage POLESTAR_ED_CELL_V54

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 848 to 863 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 55 voltage POLESTAR_CELL_V55

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 55 voltage POLESTAR_ED_CELL_V55

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 864 to 879 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 56 voltage POLESTAR_CELL_V56

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 56 voltage POLESTAR_ED_CELL_V56

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 880 to 895 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 57 voltage POLESTAR_CELL_V57

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 57 voltage POLESTAR_ED_CELL_V57

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 896 to 911 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 58 voltage POLESTAR_CELL_V58

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 144 to 159 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 58 voltage POLESTAR_ED_CELL_V58

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 912 to 927 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 59 voltage POLESTAR_CELL_V59

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 160 to 175 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 59 voltage POLESTAR_ED_CELL_V59

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 928 to 943 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 60 voltage POLESTAR_CELL_V60

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 60 voltage POLESTAR_ED_CELL_V60

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 944 to 959 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 61 voltage POLESTAR_CELL_V61

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 61 voltage POLESTAR_ED_CELL_V61

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 960 to 975 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 62 voltage POLESTAR_CELL_V62

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 62 voltage POLESTAR_ED_CELL_V62

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 976 to 991 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 63 voltage POLESTAR_CELL_V63

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 63 voltage POLESTAR_ED_CELL_V63

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 992 to 1,007 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 64 voltage POLESTAR_CELL_V64

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 240 to 255 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 64 voltage POLESTAR_ED_CELL_V64

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,008 to 1,023 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 65 voltage POLESTAR_CELL_V65

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 256 to 271 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 65 voltage POLESTAR_ED_CELL_V65

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,024 to 1,039 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 66 voltage POLESTAR_CELL_V66

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 66 voltage POLESTAR_ED_CELL_V66

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,040 to 1,055 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 67 voltage POLESTAR_CELL_V67

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 67 voltage POLESTAR_ED_CELL_V67

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,056 to 1,071 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 68 voltage POLESTAR_CELL_V68

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 304 to 319 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 68 voltage POLESTAR_ED_CELL_V68

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,072 to 1,087 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 69 voltage POLESTAR_CELL_V69

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 320 to 335 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 69 voltage POLESTAR_ED_CELL_V69

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,088 to 1,103 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 70 voltage POLESTAR_CELL_V70

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 336 to 351 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 70 voltage POLESTAR_ED_CELL_V70

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,104 to 1,119 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 71 voltage POLESTAR_CELL_V71

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 352 to 367 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 71 voltage POLESTAR_ED_CELL_V71

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,120 to 1,135 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 72 voltage POLESTAR_CELL_V72

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 368 to 383 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 72 voltage POLESTAR_ED_CELL_V72

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,136 to 1,151 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 73 voltage POLESTAR_CELL_V73

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 384 to 399 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 73 voltage POLESTAR_ED_CELL_V73

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,152 to 1,167 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 74 voltage POLESTAR_CELL_V74

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 400 to 415 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 74 voltage POLESTAR_ED_CELL_V74

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,168 to 1,183 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 75 voltage POLESTAR_CELL_V75

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 416 to 431 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 75 voltage POLESTAR_ED_CELL_V75

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,184 to 1,199 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 76 voltage POLESTAR_CELL_V76

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 432 to 447 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 76 voltage POLESTAR_ED_CELL_V76

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,200 to 1,215 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 77 voltage POLESTAR_CELL_V77

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 448 to 463 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 77 voltage POLESTAR_ED_CELL_V77

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,216 to 1,231 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 78 voltage POLESTAR_CELL_V78

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 464 to 479 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 78 voltage POLESTAR_ED_CELL_V78

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,232 to 1,247 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 79 voltage POLESTAR_CELL_V79

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 480 to 495 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 79 voltage POLESTAR_ED_CELL_V79

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,248 to 1,263 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 80 voltage POLESTAR_CELL_V80

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 496 to 511 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 80 voltage POLESTAR_ED_CELL_V80

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,264 to 1,279 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 81 voltage POLESTAR_CELL_V81

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 512 to 527 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 81 voltage POLESTAR_ED_CELL_V81

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,280 to 1,295 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 82 voltage POLESTAR_CELL_V82

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 528 to 543 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 82 voltage POLESTAR_ED_CELL_V82

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,296 to 1,311 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 83 voltage POLESTAR_CELL_V83

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 544 to 559 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 83 voltage POLESTAR_ED_CELL_V83

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,312 to 1,327 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 84 voltage POLESTAR_CELL_V84

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 560 to 575 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 84 voltage POLESTAR_ED_CELL_V84

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,328 to 1,343 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 85 voltage POLESTAR_CELL_V85

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 576 to 591 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 85 voltage POLESTAR_ED_CELL_V85

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,344 to 1,359 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 86 voltage POLESTAR_CELL_V86

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 592 to 607 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 86 voltage POLESTAR_ED_CELL_V86

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,360 to 1,375 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 87 voltage POLESTAR_CELL_V87

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 608 to 623 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 87 voltage POLESTAR_ED_CELL_V87

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,376 to 1,391 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 88 voltage POLESTAR_CELL_V88

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 624 to 639 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 88 voltage POLESTAR_ED_CELL_V88

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,392 to 1,407 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 89 voltage POLESTAR_CELL_V89

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 640 to 655 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 89 voltage POLESTAR_ED_CELL_V89

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,408 to 1,423 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 90 voltage POLESTAR_CELL_V90

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 656 to 671 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 90 voltage POLESTAR_ED_CELL_V90

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,424 to 1,439 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 91 voltage POLESTAR_CELL_V91

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 672 to 687 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 91 voltage POLESTAR_ED_CELL_V91

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,440 to 1,455 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 92 voltage POLESTAR_CELL_V92

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 688 to 703 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 92 voltage POLESTAR_ED_CELL_V92

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,456 to 1,471 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 93 voltage POLESTAR_CELL_V93

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 704 to 719 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 93 voltage POLESTAR_ED_CELL_V93

  • Request22 02 08
  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,472 to 1,487 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell 94 voltage POLESTAR_CELL_V94

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 720 to 735 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 95 voltage POLESTAR_CELL_V95

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 736 to 751 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Cell 96 voltage POLESTAR_CELL_V96

  • Request21 42
  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 752 to 767 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 V
Unit
V

In testing for 2024 to 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc