Engine parameters
The Polestar 4 has 260 engine parameters.
● Confirmed◆ In testing○ Supported× Not supported
- pedal position sensor POLESTAR_PEDAL_POS_SENS
- Request
22 2B 35 - Service 22
DID 2B35 - Module
760 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 25)- Range
- 0 to 2621 mm
- Unit
- mm
In testing for 2024 to 2026.
Accelerator pedal position POLESTAR_M3_APP_ECM
- Request
22 F4 49 - Service 22
DID F449 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2024 to 2026.
Actual power POLESTAR_ACT_POWER
- Request
22 4A 88 - Service 22
DID 4A88 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 kW
- Unit
- kW
In testing for 2024 to 2026.
Adaptive cruise target vehicle POLESTAR_ACC_TARGETVEHICLE
- Request
22 DA 12 - Service 22
DID DA12 - Module
720 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2024 to 2026.
Adaptive cruise time gap POLESTAR_ACC_TIMEGAP
- Request
22 DA 11 - Service 22
DID DA11 - Module
720 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val ÷ 2 + 0.5)- Range
- 0 to 128 s
- Unit
- s
In testing for 2024 to 2026.
Air conditioning compressor module A current POLESTAR_AC_COMP_MODULE
- Request
22 03 31 - Service 22
DID 0331 - Module
D016 → 1EC04E80 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127 A
- Unit
- A
In testing for 2024 to 2026.
Air conditioning compressor module a status POLESTAR_AC_COMP_MODULE_STAT
- Request
22 03 2F - Service 22
DID 032F - Module
D016 → 1EC04E80 - Every
250 ms - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2024 to 2026.
Air conditioning pressure POLESTAR_AC_P
- Request
22 EE 34 - Service 22
DID EE34 - Module
D016 → 1EC60E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 2)- Range
- -65536 to 65534 kPa
- Unit
- kPa
In testing for 2024 to 2026.
Air conditioning pressure POLESTAR_AC_P_V2
- Request
22 D9 00 - Service 22
DID D900 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 13107 kPa
- Unit
- kPa
In testing for 2024 to 2026.
Air conditioning relay POLESTAR_AC_RELAY
- Request
22 D9 09 - Service 22
DID D909 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2024 to 2026.
Air distribution damper motor wanted position POLESTAR_AIR_DISTRIBUTION
- Request
22 D9 04 - Service 22
DID D904 - Module
733 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 %
- Unit
- %
In testing for 2024 to 2026.
Air distribution damper motor, actual position POLESTAR_AIR_DISTRIBUTION_ACT
- Request
22 D9 09 - Service 22
DID D909 - Module
733 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 %
- Unit
- %
In testing for 2024 to 2026.
Air flow/cycle, mg/s POLESTAR_AIR_FLOW_CYCLE_MG_S
- Request
22 D9 16 - Service 22
DID D916 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553
- Unit
- Number
In testing for 2024 to 2026.
Air mass, desired POLESTAR_AIR_MASS_DES
- Request
22 D9 1F - Service 22
DID D91F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553
- Unit
- Raw value
In testing for 2024 to 2026.
Air quality sensor status POLESTAR_AIR_QUALITY_SENS
- Request
22 DC F9 - Service 22
DID DCF9 - Module
733 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2024 to 2026.
All-wheel drive coupling current POLESTAR_HALDEX_CURRENT
- Request
22 19 45 - Service 22
DID 1945 - Module
795 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2024 to 2026.
All-wheel drive coupling current POLESTAR_HALDEX_CURRENT_795
- Request
22 19 46 - Service 22
DID 1946 - Module
795 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2024 to 2026.
All-wheel drive coupling module temperature sensor 1 POLESTAR_HALDEX_ECU_T_SENS_1
- Request
22 D1 16 - Service 22
DID D116 - Module
795 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2024 to 2026.
All-wheel drive coupling module temperature sensor 2 POLESTAR_HALDEX_ECU_T_SENS_2
- Request
22 D9 00 - Service 22
DID D900 - Module
795 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2024 to 2026.
All-wheel drive coupling oil temperature POLESTAR_HALDEX_OIL_T
- Request
22 FD 04 - Service 22
DID FD04 - Module
795 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 60)- Range
- -60 to 195 °C
- Unit
- °C
In testing for 2024 to 2026.
All-wheel drive coupling pressure POLESTAR_HALDEX_P
- Request
22 19 44 - Service 22
DID 1944 - Module
795 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553
- Unit
- Raw value
In testing for 2024 to 2026.
All-wheel drive coupling rear axle torque POLESTAR_HALDEX_REAR_AXLE_TQ
- Request
22 D9 30 - Service 22
DID D930 - Module
795 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 2024 to 2026.
All-wheel drive coupling rear axle torque, requested POLESTAR_HALDEX_REAR_AXLE_TQ_REQ
- Request
22 D9 53 - Service 22
DID D953 - Module
795 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 2024 to 2026.
Alternator control mode POLESTAR_ALTERNATOR_CTRL_MODE
- Request
22 40 D1 - Service 22
DID 40D1 - Module
726 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2024 to 2026.
Alternator, amps POLESTAR_ALTERNATOR_AMPS
- Request
22 D9 24 - Service 22
DID D924 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 A
- Unit
- A
In testing for 2024 to 2026.
Automatic alignment offset POLESTAR_AUTOMATIC_ALIGNMENT
- Request
22 A2 20 - Service 22
DID A220 - Module
764 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 °
- Unit
- °
In testing for 2024 to 2026.
Average charging time left POLESTAR_AVG_CHG_TIME_LEFT
- Request
22 EE B6 - Service 22
DID EEB6 - Module
D016 → 1EC68E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 min
- Unit
- min
In testing for 2024 to 2026.
Battery management sensor reliable POLESTAR_BAT_MANAGEMENT_SENS
- Request
22 41 A7 - Service 22
DID 41A7 - Module
726 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2024 to 2026.
Bonnet closed POLESTAR_BONNET_CLOSED
- Request
22 C1 54 - Service 22
DID C154 - Module
726 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2024 to 2026.
Boost air pressure after turbocharger POLESTAR_BOOST_AIR_P_AFTER
- Request
22 03 3E - Service 22
DID 033E - Module
D016 → 1EC60E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 kPa
- Unit
- kPa
In testing for 2024 to 2026.
Boost air temperature POLESTAR_BOOST_AIR_T
- Request
22 03 41 - Service 22
DID 0341 - Module
D016 → 1EC60E80 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 5 ÷ 8 − 40)- Range
- -40 to 119 °C
- Unit
- °C
In testing for 2024 to 2026.
Boost air temperature POLESTAR_BOOST_AIR_T_7E0
- Request
22 03 41 - Service 22
DID 0341 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 5 ÷ 8 − 40)- Range
- -40 to 119 °C
- Unit
- °C
In testing for 2024 to 2026.
Boost pressure POLESTAR_BOOST_P
- Request
22 D9 41 - Service 22
DID D941 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 kPa
- Unit
- kPa
In testing for 2024 to 2026.
Boost pressure, desired value POLESTAR_BOOST_P_DES
- Request
22 D9 E4 - Service 22
DID D9E4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 kPa
- Unit
- kPa
In testing for 2024 to 2026.
Boot lid sensor POLESTAR_BOOT_LID_SENS
- Request
22 C1 50 - Service 22
DID C150 - Module
726 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 64)- Range
- 0 to 3.98
- Unit
- Number
In testing for 2024 to 2026.
Burning time, hours POLESTAR_BURNING_TIME_HOURS
- Request
22 9A 0B - Service 22
DID 9A0B - Module
7E3 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2024 to 2026.
Burning time, minutes POLESTAR_BURNING_TIME_MINUTES
- Request
22 9A 0B - Service 22
DID 9A0B - Module
7E3 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2024 to 2026.
Calculated load POLESTAR_CALC_LOAD
Pelican can show this parameter as the engine load.
- Request
22 F4 04 - Service 22
DID F404 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2024 to 2026.
Central lock POLESTAR_CENTRAL_LOCK
- Request
22 C2 59 - Service 22
DID C259 - Module
726 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127
- Unit
- Number
In testing for 2024 to 2026.
Charging POLESTAR_CHG_MS_CAN
- Request
22 D9 01 - Service 22
DID D901 - Module
791 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 1)- Range
- -1 to 254
- Unit
- Number
In testing for 2024 to 2026.
Charging state POLESTAR_CHG_ST
- Request
22 EE 1D - Service 22
DID EE1D - Module
D016 → 1EC68E80 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2024 to 2026.
Cold zone count POLESTAR_CEM_COLD_ZONE
- Request
22 D9 FE - Service 22
DID D9FE - Module
733 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2024 to 2026.
Combustion air fan POLESTAR_COMBUSTION_AIR_FAN
- Request
22 9A 06 - Service 22
DID 9A06 - Module
7E3 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2024 to 2026.
Compressor inlet sensor pressure POLESTAR_COMP_INLET_SENS_P
- Request
22 03 03 - Service 22
DID 0303 - Module
D016 → 1EC04E80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 bar
- Unit
- bar
In testing for 2024 to 2026.
Compressor inlet sensor temperature POLESTAR_COMP_INLET_SENS_T
- Request
22 EE 36 - Service 22
DID EE36 - Module
D016 → 1EC60E80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.14)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2024 to 2026.
Compressor inlet sensor temperature POLESTAR_COMP_INLET_SENS_T_D016
- Request
22 03 03 - Service 22
DID 0303 - Module
D016 → 1EC04E80 - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 100 − 40)- Range
- -40 to 615 °C
- Unit
- °C
In testing for 2024 to 2026.
Compressor outlet sensor pressure POLESTAR_COMP_OUTLET_SENS_P
- Request
22 03 29 - Service 22
DID 0329 - Module
D016 → 1EC04E80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 bar
- Unit
- bar
In testing for 2024 to 2026.
Compressor outlet sensor temperature POLESTAR_COMP_OUTLET_SENS_T
- Request
22 EE 38 - Service 22
DID EE38 - Module
D016 → 1EC60E80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.14)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2024 to 2026.
Compressor outlet sensor temperature POLESTAR_COMP_OUTLET_SENS_T_D016
- Request
22 03 29 - Service 22
DID 0329 - Module
D016 → 1EC04E80 - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 100 − 40)- Range
- -40 to 615 °C
- Unit
- °C
In testing for 2024 to 2026.
Control module power supply POLESTAR_CTRL_MODULE_POWER
- Request
22 D1 11 - Service 22
DID D111 - Module
733 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2024 to 2026.
Control module temperature POLESTAR_CTRL_MODULE_T
- Request
22 D9 B8 - Service 22
DID D9B8 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 5 ÷ 8 − 40)- Range
- -40 to 119 °C
- Unit
- °C
In testing for 2024 to 2026.
Coolant pump current POLESTAR_ED_PUMP_A
- Request
22 23 09 - Service 22
DID 2309 - Module
7E5 → 7ED - Every
60 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val ÷ 5)- Range
- 0 to 51 A
- Unit
- A
In testing for 2024 to 2026.
Coolant pump relay POLESTAR_CLT_PMP_RELAY
- Request
22 D9 5B - Service 22
DID D95B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2024 to 2026.
Coolant pump speed POLESTAR_ED_PUMP_DUTY
- Request
22 D0 32 - Service 22
DID D032 - Module
7E5 → 7ED - Every
60 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2.55)- Range
- 0 to 100 %
- Unit
- %
In testing for 2024 to 2026.
Coolant pump temperature POLESTAR_ED_PUMP_T
- Request
22 23 0A - Service 22
DID 230A - Module
7E5 → 7ED - Every
60 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2024 to 2026.
Coolant pump voltage POLESTAR_ED_PUMP_V
- Request
22 23 08 - Service 22
DID 2308 - Module
7E5 → 7ED - Every
60 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2024 to 2026.
Coolant temperature POLESTAR_ED_COOLANT_T
- Request
22 20 47 - Service 22
DID 2047 - Module
7E5 → 7ED - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 8)- Range
- 0 to 8191.875 °C
- Unit
- °C
In testing for 2024 to 2026.
Cooling fan speed POLESTAR_ED_FAN_DUTY
- Request
22 D0 41 - Service 22
DID D041 - Module
7E5 → 7ED - Every
60 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2.55)- Range
- 0 to 100 %
- Unit
- %
In testing for 2024 to 2026.
Counter POLESTAR_CNT_MS_CAN
- Request
22 9A 0D - Service 22
DID 9A0D - Module
7E3 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2024 to 2026.
Cylinder 1 misfire POLESTAR_MIS_1
- Request
22 F6 A2 - Service 22
DID F6A2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2024 to 2026.
Cylinder 1 misfire average POLESTAR_MIS_AVG_1
- Request
22 DA B6 - Service 22
DID DAB6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2024 to 2026.
Cylinder 2 misfire POLESTAR_MIS_2_V2
- Request
22 F6 A3 - Service 22
DID F6A3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2024 to 2026.
Cylinder 2 misfire average POLESTAR_MIS_AVG_2
- Request
22 DA B6 - Service 22
DID DAB6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2024 to 2026.
Cylinder 3 misfire POLESTAR_MIS_3_V2
- Request
22 F6 A4 - Service 22
DID F6A4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2024 to 2026.
Cylinder 3 misfire average POLESTAR_MIS_AVG_3
- Request
22 DA B6 - Service 22
DID DAB6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2024 to 2026.
Cylinder 4 misfire POLESTAR_MIS_4
- Request
22 F6 A5 - Service 22
DID F6A5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2024 to 2026.
Cylinder 4 misfire average POLESTAR_MIS_AVG_4
- Request
22 DA B6 - Service 22
DID DAB6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2024 to 2026.
Cylinder 5 misfire average POLESTAR_MIS_AVG_5
- Request
22 DA B6 - Service 22
DID DAB6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2024 to 2026.
Cylinder 6 misfire average POLESTAR_MIS_AVG_6
- Request
22 DA B6 - Service 22
DID DAB6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2024 to 2026.
Cylinder 7 misfire average POLESTAR_MIS_AVG_7
- Request
22 DA B6 - Service 22
DID DAB6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2024 to 2026.
Cylinder 8 misfire average POLESTAR_MIS_AVG_8
- Request
22 DA B6 - Service 22
DID DAB6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2024 to 2026.
Days since last service POLESTAR_DAYS_SINCE_SERVICE
- Request
22 D9 03 - Service 22
DID D903 - Module
D018 → 1F002E80 - Every
30 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2024 to 2026.
Defroster damper motor wanted position POLESTAR_DEFROSTER_DAMPER
- Request
22 D9 00 - Service 22
DID D900 - Module
733 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 %
- Unit
- %
In testing for 2024 to 2026.
Defroster damper motor, actual position POLESTAR_DEFROSTER_DAMPER_ACT
- Request
22 D9 05 - Service 22
DID D905 - Module
733 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 %
- Unit
- %
In testing for 2024 to 2026.
Diesel particulate filter additive pump POLESTAR_M3_ADM_ADDITIVE_PMP
- Request
22 D9 04 - Service 22
DID D904 - Module
7C0 - Every
1 s - Testing
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2024 to 2026.
Diesel particulate filter pressure POLESTAR_DPF_P
- Request
22 DA C8 - Service 22
DID DAC8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2024 to 2026.
Diesel particulate filter soot POLESTAR_DPF_SOOT
- Request
22 D9 F2 - Service 22
DID D9F2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655
- Unit
- Raw value
In testing for 2024 to 2026.
Diesel particulate filter temperature POLESTAR_DPF_T
- Request
22 D9 F9 - Service 22
DID D9F9 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.14)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2024 to 2026.
Dipped beam POLESTAR_DIPPED_BEAM
- Request
22 71 51 - Service 22
DID 7151 - Module
726 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2024 to 2026.
Display illumination intensity POLESTAR_LCD_ILUMINATION
- Request
22 DB 01 - Service 22
DID DB01 - Module
784 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 2024 to 2026.
Display temperature POLESTAR_DISPLAY_T_MS_CAN
- Request
22 D9 06 - Service 22
DID D906 - Module
784 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276
- Unit
- Number
In testing for 2024 to 2026.
Distance to next service POLESTAR_EQA_SERVICE_DIST
- Request
22 65 04 - Service 22
DID 6504 - Module
7E5 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 km
- Unit
- km
In testing for 2024 to 2026.
Downtime POLESTAR_DOWNTIME
- Request
22 EE D6 - Service 22
DID EED6 - Module
726 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5
- Unit
- Raw value
In testing for 2024 to 2026.
Electric drivetrain coolant temperature, IEM inlet POLESTAR_ELEC_DRIVETRAIN_ECT
- Request
22 98 5E - Service 22
DID 985E - Module
D016 → 1EC6EE80 - Every
5 s - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
(val − 40)- Range
- -2147483688 to 2147483607 °C
- Unit
- °C
In testing for 2024 to 2026.
Electric drivetrain coolant temperature, IEM outlet POLESTAR_ELEC_DRIVETRAIN_ECT_IEM
- Request
22 98 5E - Service 22
DID 985E - Module
D016 → 1EC6EE80 - Every
5 s - Testing
Bits 32 to 63 of the reply, 32 bits. The value is signed.
- Formula
(val − 40)- Range
- -2147483688 to 2147483607 °C
- Unit
- °C
In testing for 2024 to 2026.
Electric drivetrain coolant temperature, IHFA inlet POLESTAR_ELEC_DRIVETRAIN_ECT_IHFA
- Request
22 98 5E - Service 22
DID 985E - Module
D016 → 1ED24E80 - Every
5 s - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
(val − 40)- Range
- -2147483688 to 2147483607 °C
- Unit
- °C
In testing for 2024 to 2026.
Electric drivetrain coolant temperature, IHFA outlet POLESTAR_ELEC_DRIVETRAIN_ECT_IHFA_OUTLET
- Request
22 98 5E - Service 22
DID 985E - Module
D016 → 1ED24E80 - Every
5 s - Testing
Bits 32 to 63 of the reply, 32 bits. The value is signed.
- Formula
(val − 40)- Range
- -2147483688 to 2147483607 °C
- Unit
- °C
In testing for 2024 to 2026.
Electric front axle drive torque POLESTAR_ELECTRICAL_FRONT
- Request
22 49 D4 - Service 22
DID 49D4 - Module
D016 → 1ED24E80 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
(val − 1024)- Range
- -2147484672 to 2147482623 N·m
- Unit
- N·m
In testing for 2024 to 2026.
Electric rear axle drive calculated torque POLESTAR_ERAD_CALC_TQ
- Request
22 EF 12 - Service 22
DID EF12 - Module
D016 → 1EC6EE80 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 4 − 8188)- Range
- -8188 to 253952 N·m
- Unit
- N·m
In testing for 2024 to 2026.
Electric rear axle drive calculated torque POLESTAR_ERAD_CALC_TQ_D016
- Request
22 EE 09 - Service 22
DID EE09 - Module
D016 → 1EC6EE80 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 4 − 8188)- Range
- -8188 to 253952 N·m
- Unit
- N·m
In testing for 2024 to 2026.
Electric rear axle drive motor winding temperature sensor 1 POLESTAR_ERAD_MOTOR_WINDING_T_1
- Request
22 4A 00 - Service 22
DID 4A00 - Module
D016 → 1EC6EE80 - Every
5 s - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -214748364 to 214748364 °C
- Unit
- °C
In testing for 2024 to 2026.
Electric rear axle drive motor winding temperature sensor 2 POLESTAR_ERAD_MOTOR_WINDING_T_2
- Request
22 4A 01 - Service 22
DID 4A01 - Module
D016 → 1EC6EE80 - Every
5 s - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -214748364 to 214748364 °C
- Unit
- °C
In testing for 2024 to 2026.
Engine coolant fan POLESTAR_ENG_CLT_FAN
- Request
22 EE 6F - Service 22
DID EE6F - Module
D016 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 %
- Unit
- %
In testing for 2024 to 2026.
Engine oil pressure POLESTAR_EOP
- Request
22 EE 37 - Service 22
DID EE37 - Module
D016 → 1EC60E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 kPa
- Unit
- kPa
In testing for 2024 to 2026.
Engine oil pressure POLESTAR_EOP_V2
- Request
22 EF 4E - Service 22
DID EF4E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 kPa
- Unit
- kPa
In testing for 2024 to 2026.
Engine oil temperature POLESTAR_EOT
Pelican can show this parameter as the engine oil temperature.
- Request
22 EE 58 - Service 22
DID EE58 - Module
D016 → 1EC60E80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.14)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2024 to 2026.
Engine oil temperature POLESTAR_EOT_V2
Pelican can show this parameter as the engine oil temperature.
- Request
22 D9 DC - Service 22
DID D9DC - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.14)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2024 to 2026.
Engine time since last service POLESTAR_ENG_TIME_SINCE
- Request
22 63 0E - Service 22
DID 630E - Module
720 - Every
30 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2024 to 2026.
Engine torque POLESTAR_ENG_TQ
- Request
22 DA 89 - Service 22
DID DA89 - Module
D016 → 1EC64E80 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 512)- Range
- -512 to 6041 N·m
- Unit
- N·m
In testing for 2024 to 2026.
Evaporator temperature POLESTAR_EVAPORATOR_T
- Request
22 98 4F - Service 22
DID 984F - Module
D01A → 1F422E80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 °C
- Unit
- °C
In testing for 2024 to 2026.
Evaporator temperature POLESTAR_EVAPORATOR_T_MS_CAN
- Request
22 D9 98 - Service 22
DID D998 - Module
733 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64 − 100)- Range
- -100 to 923 °C
- Unit
- °C
In testing for 2024 to 2026.
Exhaust gas recirculation bypass valve POLESTAR_EGR_BYPASS_VLV
- Request
22 EE 7F - Service 22
DID EE7F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 2024 to 2026.
Exhaust gas recirculation cooler bypass actuator position POLESTAR_EGR_COOLER_BYPASS
- Request
22 DA D2 - Service 22
DID DAD2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 %
- Unit
- %
In testing for 2024 to 2026.
Exhaust gas recirculation valve position sensor POLESTAR_EGR_VLV_POS_SENS
- Request
22 DA AD - Service 22
DID DAAD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 %
- Unit
- %
In testing for 2024 to 2026.
Exhaust gas recirculation valve, commanded position POLESTAR_EGR_VLV_CMD_POS
- Request
22 DC 01 - Service 22
DID DC01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 %
- Unit
- %
In testing for 2024 to 2026.
Exhaust gas recirculation valve, commanded position II POLESTAR_EGR_VLV_CMD_POS_II
- Request
22 D9 6D - Service 22
DID D96D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 %
- Unit
- %
In testing for 2024 to 2026.
Fan POLESTAR_FAN
- Request
22 DC 02 - Service 22
DID DC02 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 %
- Unit
- %
In testing for 2024 to 2026.
Front axle sensor POLESTAR_FRONT_AXLE_SENS
- Request
22 3B 71 - Service 22
DID 3B71 - Module
726 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 40)- Range
- 0 to 6.37 V
- Unit
- V
In testing for 2024 to 2026.
Front oxygen sensor heating POLESTAR_FRONT_OXYGEN_SENS
- Request
22 DA 59 - Service 22
DID DA59 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 ms
- Unit
- ms
In testing for 2024 to 2026.
Glow plug pulse ratio POLESTAR_GLOW_PLUG_RAT_MS_CAN
- Request
22 9A 04 - Service 22
DID 9A04 - Module
7E3 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2.55)- Range
- 0 to 100 %
- Unit
- %
In testing for 2024 to 2026.
Glow plugs POLESTAR_GLOW_PLUGS
- Request
22 D9 A0 - Service 22
DID D9A0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 %
- Unit
- %
In testing for 2024 to 2026.
Grill shutter open POLESTAR_GRILL_SHUTTER_OPEN
- Request
22 07 07 - Service 22
DID 0707 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2024 to 2026.
High beam POLESTAR_HIGH_BEAM
- Request
22 71 51 - Service 22
DID 7151 - Module
726 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2024 to 2026.
High voltage coolant heater A, inlet temperature POLESTAR_HIGH_V_CLT_HEATER_T
- Request
22 03 2B - Service 22
DID 032B - Module
D016 → 1EC04E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100 − 40)- Range
- -40 to 615 °C
- Unit
- °C
In testing for 2024 to 2026.
High voltage coolant heater A, outlet temperature POLESTAR_HIGH_V_CLT_HEATER_OUTLET_T
- Request
22 03 2B - Service 22
DID 032B - Module
D016 → 1EC04E80 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 100 − 40)- Range
- -40 to 615 °C
- Unit
- °C
In testing for 2024 to 2026.
High voltage ED coolant temperature 2 POLESTAR_HIGH_V_ED_ECT_2
- Request
22 EF 73 - Service 22
DID EF73 - Module
D016 → 1EC60E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2024 to 2026.
High voltage motor coolant pump POLESTAR_HIGH_V_MOTOR_CLT_PMP
- Request
22 EF 71 - Service 22
DID EF71 - Module
D016 → 1EC60E80 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 rpm
- Unit
- rpm
In testing for 2024 to 2026.
High voltage system current POLESTAR_HIGH_V_SYSTEM
- Request
22 98 61 - Service 22
DID 9861 - Module
D016 → 1EC6EE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 + 40)- Range
- -3236 to 3316 A
- Unit
- A
In testing for 2024 to 2026.
High voltage system current POLESTAR_HIGH_V_SYSTEM_CURRENT
- Request
22 98 61 - Service 22
DID 9861 - Module
D016 → 1ED24E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 + 40)- Range
- -3236 to 3316 A
- Unit
- A
In testing for 2024 to 2026.
High voltage system current POLESTAR_HIGH_V_SYSTEM_XC
- Request
22 EF 13 - Service 22
DID EF13 - Module
D016 → 1EC6EE80 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 2 − 250)- Range
- -250 to 260 A
- Unit
- A
In testing for 2024 to 2026.
High-voltage coolant heater current POLESTAR_CURRENT_CONS_HVCH
- Request
22 43 45 - Service 22
DID 4345 - Module
D01A → 1F422E80 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 4)- Range
- 0 to 63.75 A
- Unit
- A
In testing for 2024 to 2026.
High-voltage coolant heater power POLESTAR_CURRENT_CONS_HVCH_W
- Request
22 43 45 - Service 22
DID 4345 - Module
D01A → 1F422E80 - Every
1 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val × 20)- Range
- 0 to 1310700 W
- Unit
- W
In testing for 2024 to 2026.
High-voltage coolant heater requested power POLESTAR_REQ_CONS_HVCH_CCM_W
- Request
22 43 45 - Service 22
DID 4345 - Module
D01A → 1F422E80 - Every
1 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
(val × 20)- Range
- 0 to 1310700 W
- Unit
- W
In testing for 2024 to 2026.
Ignition angle before top dead center POLESTAR_IGN_ANG_BTDC
- Request
22 F4 0E - Service 22
DID F40E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 64)- Range
- -64 to 63.5
- Unit
- Number
In testing for 2024 to 2026.
In car temperature POLESTAR_CAR_T
- Request
22 DD 04 - Service 22
DID DD04 - Module
726 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2024 to 2026.
In car temperature POLESTAR_CAR_T_MS_CAN_7E3
- Request
22 DD 04 - Service 22
DID DD04 - Module
7E3 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2024 to 2026.
In-car temperature POLESTAR_CAR_T_720
- Request
22 DD 04 - Service 22
DID DD04 - Module
720 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2024 to 2026.
In-car temperature POLESTAR_CAR_T_MS_CAN
- Request
22 9A 1B - Service 22
DID 9A1B - Module
733 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64 − 100)- Range
- -100 to 923 °C
- Unit
- °C
In testing for 2024 to 2026.
Infotainment ring optical fiber test POLESTAR_MOST_OPTICAL_FIBRE
- Request
22 83 1F - Service 22
DID 831F - Module
784 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2024 to 2026.
Input torque calculated POLESTAR_INPUT_TQ_CALC
- Request
22 D9 62 - Service 22
DID D962 - Module
795 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 8 − 16376)- Range
- -16376 to 507904 N·m
- Unit
- N·m
In testing for 2024 to 2026.
Input torque, requested POLESTAR_INPUT_TQ_REQ
- Request
22 D9 56 - Service 22
DID D956 - Module
795 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 8 − 16376)- Range
- -16376 to 507904 N·m
- Unit
- N·m
In testing for 2024 to 2026.
Intake air temperature, manifold sensor POLESTAR_TMAP_IAT
- Request
22 D9 AB - Service 22
DID D9AB - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.14)- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2024 to 2026.
Interior temperature POLESTAR_INTERIOR_T
- Request
22 98 43 - Service 22
DID 9843 - Module
D01A → 1F422E80 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 4 ÷ 5 − 60)- Range
- -60 to 144 °C
- Unit
- °C
In testing for 2024 to 2026.
Lateral angle POLESTAR_LATERAL_ANG
- Request
22 2B 0C - Service 22
DID 2B0C - Module
760 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 °
- Unit
- °
In testing for 2024 to 2026.
Leading A/T POLESTAR_LEADING_T
- Request
22 1E 2F - Service 22
DID 1E2F - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 2024 to 2026.
Left seat heater POLESTAR_LEFT_SEAT_HEATER_MS
- Request
22 9A 21 - Service 22
DID 9A21 - Module
733 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 °C
- Unit
- °C
In testing for 2024 to 2026.
Left temperature damper motor wanted position POLESTAR_LEFT_T_DAMPER_MOTOR
- Request
22 D9 02 - Service 22
DID D902 - Module
733 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 %
- Unit
- %
In testing for 2024 to 2026.
Left temperature damper motor, actual position POLESTAR_LEFT_T_DAMPER_MOTOR_ACT
- Request
22 D9 07 - Service 22
DID D907 - Module
733 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 %
- Unit
- %
In testing for 2024 to 2026.
Load POLESTAR_LOAD
- Request
22 F4 43 - Service 22
DID F443 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 25700 %
- Unit
- %
In testing for 2024 to 2026.
M3 APP, CAN POLESTAR_M3_APP_CAN
- Request
22 F4 4A - Service 22
DID F44A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2024 to 2026.
M3 diff.press. POLESTAR_M3_DIFF_PRESS
- Request
22 D9 F3 - Service 22
DID D9F3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2024 to 2026.
M3 DPF soot POLESTAR_M3_DPF_SOOT
- Request
22 D9 F2 - Service 22
DID D9F2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.55 g
- Unit
- g
In testing for 2024 to 2026.
M3 EGR DC POLESTAR_M3_EGR_DC
- Request
22 D9 6C - Service 22
DID D96C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 %
- Unit
- %
In testing for 2024 to 2026.
M3 IAT, butterfly POLESTAR_M3_IAT_BUTTERFLY
- Request
22 F4 0F - Service 22
DID F40F - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2024 to 2026.
M3 IAT, MAF POLESTAR_M3_IAT_MAF
- Request
22 D9 1C - Service 22
DID D91C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 °C
- Unit
- °C
In testing for 2024 to 2026.
Misfire catalytic damage total - petrol POLESTAR_MIS_CATALYTIC_DAMAGE
- Request
22 DA 03 - Service 22
DID DA03 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2024 to 2026.
Misfire emission related total - petrol POLESTAR_MIS_EMISSION_RELATED
- Request
22 DA 04 - Service 22
DID DA04 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2024 to 2026.
Misfires, cylinder 2 POLESTAR_MIS_2
- Request
22 EF 71 - Service 22
DID EF71 - Module
D016 → 1EC60E80 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2024 to 2026.
Misfires, cylinder 3 POLESTAR_MIS_3
- Request
22 EF 71 - Service 22
DID EF71 - Module
D016 → 1EC60E80 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2024 to 2026.
Module current POLESTAR_MODULE_CURRENT
- Request
22 19 46 - Service 22
DID 1946 - Module
D016 → 1EC70E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2024 to 2026.
Months since last service POLESTAR_MONTHS_SINCE_SERVICE
- Request
22 63 0E - Service 22
DID 630E - Module
720 - Every
30 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 120)- Range
- 0 to 546
- Unit
- Number
In testing for 2024 to 2026.
MOST lock POLESTAR_MOST_LOCK_MS_CAN
- Request
22 DB 16 - Service 22
DID DB16 - Module
784 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2024 to 2026.
MOST network number of modules POLESTAR_MOST_NETWORK_NUM
- Request
22 83 35 - Service 22
DID 8335 - Module
784 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2024 to 2026.
Motor hours since last service POLESTAR_MOTOR_HOURS_SINCE
- Request
22 D9 03 - Service 22
DID D903 - Module
D018 → 1F002E80 - Every
30 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 h
- Unit
- h
In testing for 2024 to 2026.
Navigation altitude POLESTAR_SENSUS_CONNECT_GPS
- Request
22 80 12 - Service 22
DID 8012 - Module
784 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 180)- Range
- 0 to 364 °
- Unit
- °
In testing for 2024 to 2026.
Navigation fix POLESTAR_SENSUS_CONNECT_GPS_FIX_MS
- Request
22 80 12 - Service 22
DID 8012 - Module
784 - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 °
- Unit
- °
In testing for 2024 to 2026.
Navigation heading POLESTAR_SENSUS_CONNECT_GPS_HEADING
- Request
22 80 12 - Service 22
DID 8012 - Module
784 - Every
1 s - Testing
Bits 104 to 119 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 °
- Unit
- °
In testing for 2024 to 2026.
Navigation number of satellites POLESTAR_SENSUS_CONNECT_GPS_NUM
- Request
22 80 35 - Service 22
DID 8035 - Module
784 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2024 to 2026.
On-board charger module temperature POLESTAR_OBC_T
- Request
22 EE 19 - Service 22
DID EE19 - Module
D016 → 1EC68E80 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2024 to 2026.
Operating state POLESTAR_OP_ST_MS_CAN
- Request
22 9A 08 - Service 22
DID 9A08 - Module
7E3 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2024 to 2026.
Outdoor temperature, BCM POLESTAR_OUTDOOR_T_BCM
- Request
22 DD 05 - Service 22
DID DD05 - Module
760 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2024 to 2026.
Outside heat exchanger outlet sensor pressure POLESTAR_OUTSIDE_HEAT_P
- Request
22 EE 48 - Service 22
DID EE48 - Module
D016 → 1EC60E80 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
val- Range
- -2147483648 to 2147483647
- Unit
- Raw value
In testing for 2024 to 2026.
Outside heat exchanger outlet sensor temperature POLESTAR_OUTSIDE_HEAT_T
- Request
22 EE 47 - Service 22
DID EE47 - Module
D016 → 1EC60E80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.14)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2024 to 2026.
Parking heater counter POLESTAR_PARKING_HEATER_CNT
- Request
22 9A 0E - Service 22
DID 9A0E - Module
7E3 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2024 to 2026.
Parking lights POLESTAR_PARKING_LIGHTS
- Request
22 71 51 - Service 22
DID 7151 - Module
726 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2024 to 2026.
Passenger airbag activated POLESTAR_PASSENGER_AIRBAG_ACTIVATED
- Request
22 5B 29 - Service 22
DID 5B29 - Module
737 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2024 to 2026.
Passenger airbag cutoff switch POLESTAR_PASSENGER_AIRBAG
- Request
22 5B 28 - Service 22
DID 5B28 - Module
737 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127
- Unit
- Number
In testing for 2024 to 2026.
Passenger airbag OFF lamp POLESTAR_PASSENGER_AIRBAG_OFF
- Request
22 61 A5 - Service 22
DID 61A5 - Module
737 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val ÷ 32)- Range
- 0 to 7.96
- Unit
- Number
In testing for 2024 to 2026.
Power mode POLESTAR_POWER_MODE
- Request
22 DD 06 - Service 22
DID DD06 - Module
726 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 192)- Range
- -192 to 63
- Unit
- Number
In testing for 2024 to 2026.
Power mode POLESTAR_POWER_MODE_MS_CAN
- Request
22 DD 07 - Service 22
DID DD07 - Module
784 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 99)- Range
- -99 to 156
- Unit
- Number
In testing for 2024 to 2026.
Power mode POLESTAR_POWER_MODE_MS_CAN_7E3
- Request
22 DD 06 - Service 22
DID DD06 - Module
7E3 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2024 to 2026.
Quiescent current average POLESTAR_QUIESCENT_CURRENT
- Request
22 40 25 - Service 22
DID 4025 - Module
726 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2 − 1000)- Range
- -1000 to 31767 mA
- Unit
- mA
In testing for 2024 to 2026.
Rear axle sensor POLESTAR_REAR_AXLE_SENS
- Request
22 3B 73 - Service 22
DID 3B73 - Module
726 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 40)- Range
- 0 to 6.37 V
- Unit
- V
In testing for 2024 to 2026.
Rear defroster automatic POLESTAR_REAR_DEFROSTER
- Request
22 D9 18 - Service 22
DID D918 - Module
733 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2024 to 2026.
Rear left seat heater POLESTAR_RL_SEAT_HEATER_MS
- Request
22 9A 23 - Service 22
DID 9A23 - Module
733 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 °C
- Unit
- °C
In testing for 2024 to 2026.
Rear oxygen sensor heating POLESTAR_REAR_OXYGEN_SENS
- Request
22 DB 77 - Service 22
DID DB77 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 ms
- Unit
- ms
In testing for 2024 to 2026.
Rear right seat heater POLESTAR_RR_SEAT_HEATER_MS
- Request
22 9A 24 - Service 22
DID 9A24 - Module
733 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 °C
- Unit
- °C
In testing for 2024 to 2026.
Recirculation damper motor wanted position POLESTAR_RECIRCULATION_DAMPER
- Request
22 D9 01 - Service 22
DID D901 - Module
733 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 %
- Unit
- %
In testing for 2024 to 2026.
Recirculation damper motor, actual position POLESTAR_RECIRCULATION_DAMPER_ACT
- Request
22 D9 06 - Service 22
DID D906 - Module
733 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 %
- Unit
- %
In testing for 2024 to 2026.
Remote key POLESTAR_REMOTE_KEY
- Request
22 41 2D - Service 22
DID 412D - Module
726 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2024 to 2026.
Right seat heater POLESTAR_RIGHT_SEAT_HEATER_MS
- Request
22 9A 22 - Service 22
DID 9A22 - Module
733 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 °C
- Unit
- °C
In testing for 2024 to 2026.
Right temperature damper motor wanted position POLESTAR_RIGHT_T_DAMPER_MOTOR
- Request
22 D9 03 - Service 22
DID D903 - Module
733 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 %
- Unit
- %
In testing for 2024 to 2026.
Right temperature damper motor, actual position POLESTAR_RIGHT_T_DAMPER_MOTOR_ACT
- Request
22 D9 08 - Service 22
DID D908 - Module
733 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 %
- Unit
- %
In testing for 2024 to 2026.
Running time, hours POLESTAR_RUNNING_TIME_HOURS
- Request
22 9A 0C - Service 22
DID 9A0C - Module
7E3 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2024 to 2026.
Running time, minutes POLESTAR_RUNNING_TIME_MINUTES
- Request
22 9A 0C - Service 22
DID 9A0C - Module
7E3 - Every
3600 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2024 to 2026.
Seat buckle driver locked POLESTAR_SEAT_BUCKLE_DRIVER
- Request
22 5B 19 - Service 22
DID 5B19 - Module
737 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127
- Unit
- Number
In testing for 2024 to 2026.
Seat buckle passenger locked POLESTAR_SEAT_BUCKLE
- Request
22 5B 1A - Service 22
DID 5B1A - Module
737 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127
- Unit
- Number
In testing for 2024 to 2026.
Seat buckle rear center locked POLESTAR_SEAT_BUCKLE_REAR
- Request
22 5B 47 - Service 22
DID 5B47 - Module
737 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2024 to 2026.
Seat buckle rear left locked POLESTAR_SEAT_BUCKLE_RL
- Request
22 5B 46 - Service 22
DID 5B46 - Module
737 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2024 to 2026.
Seat buckle rear right locked POLESTAR_SEAT_BUCKLE_RR
- Request
22 5B 48 - Service 22
DID 5B48 - Module
737 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2024 to 2026.
Servo control module temperature POLESTAR_SERVO_CTRL_MODULE_T
- Request
22 D1 1C - Service 22
DID D11C - Module
730 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2024 to 2026.
Servo pump engine power consumption POLESTAR_SERVO_PMP_ENG_POWER
- Request
22 41 39 - Service 22
DID 4139 - Module
730 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127 A
- Unit
- A
In testing for 2024 to 2026.
Slave A/T POLESTAR_SLAVE_T
- Request
22 1E 1B - Service 22
DID 1E1B - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 2024 to 2026.
SLC1 current POLESTAR_SLC1_CURRENT
- Request
22 D9 0C - Service 22
DID D90C - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2024 to 2026.
SLC2 current POLESTAR_SLC2_CURRENT
- Request
22 D9 0F - Service 22
DID D90F - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2024 to 2026.
SLC3 current POLESTAR_SLC3_CURRENT
- Request
22 D9 10 - Service 22
DID D910 - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2024 to 2026.
Starter relay POLESTAR_STARTER_RELAY
- Request
22 D9 50 - Service 22
DID D950 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2024 to 2026.
Starter relay 1 POLESTAR_STARTER_RELAY_1
- Request
22 DA 12 - Service 22
DID DA12 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2024 to 2026.
Starter relay 2 POLESTAR_STARTER_RELAY_2
- Request
22 EE EB - Service 22
DID EEEB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2024 to 2026.
Steering angle, actual value POLESTAR_STEER_ANG_ACT
- Request
22 33 02 - Service 22
DID 3302 - Module
760 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276
- Unit
- Raw value
In testing for 2024 to 2026.
Steering shaft torque POLESTAR_STEER_SHFT_TQ
- Request
22 33 0C - Service 22
DID 330C - Module
730 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10 − 12.7)- Range
- -12.7 to 12.8 N·m
- Unit
- N·m
In testing for 2024 to 2026.
Supplementary heater counter POLESTAR_SUPPLEMENTARY_HEATER
- Request
22 9A 0F - Service 22
DID 9A0F - Module
7E3 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2024 to 2026.
System relay POLESTAR_SYSTEM_RELAY
- Request
22 D9 4F - Service 22
DID D94F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2024 to 2026.
Tailgate closing motor POLESTAR_TAILGATE_CLOSING
- Request
22 D9 08 - Service 22
DID D908 - Module
775 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2024 to 2026.
Tailgate hall sensor signal POLESTAR_TAILGATE_HALL_SENS
- Request
22 D9 04 - Service 22
DID D904 - Module
775 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2024 to 2026.
Tailgate handle button POLESTAR_TAILGATE_HANDLE
- Request
22 D9 00 - Service 22
DID D900 - Module
775 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2024 to 2026.
Tailgate motor protection POLESTAR_TAILGATE_MOTOR
- Request
22 EE 04 - Service 22
DID EE04 - Module
775 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2024 to 2026.
Tailgate opening motor POLESTAR_TAILGATE_OPENING
- Request
22 D9 07 - Service 22
DID D907 - Module
775 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2024 to 2026.
Tailgate opening position POLESTAR_TAILGATE_OPENING_POS
- Request
22 D9 09 - Service 22
DID D909 - Module
775 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2024 to 2026.
Tailgate power supply POLESTAR_TAILGATE_POWER_SUP
- Request
22 D1 11 - Service 22
DID D111 - Module
775 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2024 to 2026.
Tailgate switch 1-2 POLESTAR_TAILGATE_SWITCH_1_2
- Request
22 D9 01 - Service 22
DID D901 - Module
775 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2024 to 2026.
Temperature left setting POLESTAR_T_LEFT_SETTING_MS
- Request
22 D9 30 - Service 22
DID D930 - Module
733 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2)- Range
- 0 to 32767 °C
- Unit
- °C
In testing for 2024 to 2026.
Temperature right setting POLESTAR_T_RIGHT_SETTING_MS
- Request
22 D9 31 - Service 22
DID D931 - Module
733 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2)- Range
- 0 to 32767 °C
- Unit
- °C
In testing for 2024 to 2026.
Throttle absolute position POLESTAR_THROTTLE_ABS_POS
Pelican can show this parameter as the throttle position.
- Request
22 F4 11 - Service 22
DID F411 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2024 to 2026.
Time since engine start POLESTAR_TIME_SINCE_ENG_START
- Request
22 F4 1F - Service 22
DID F41F - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 s
- Unit
- s
In testing for 2024 to 2026.
Torque converter lock-up solenoid POLESTAR_LOCK_UP_SOLENOID_SLU_7E1
- Request
22 DA 4C - Service 22
DID DA4C - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2024 to 2026.
Torque converter lock-up solenoid current POLESTAR_LOCK_UP_SOLENOID_SLU_CURRENT
- Request
22 1E 47 - Service 22
DID 1E47 - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2024 to 2026.
Torque converter lock-up solenoid current, requested POLESTAR_LOCK_UP_SOLENOID_SLU
- Request
22 1E 41 - Service 22
DID 1E41 - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2024 to 2026.
Torque converter lock-up solenoid, requested POLESTAR_LOCK_UP_SOLENOID_SLU_REQ
- Request
22 DA 4B - Service 22
DID DA4B - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2024 to 2026.
Torque from engine POLESTAR_TQ_ENG
- Request
22 E5 01 - Service 22
DID E501 - Module
DA18 → 18 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 2024 to 2026.
Total engine running time at last service POLESTAR_TOT_ENG_RUNNING_TIME
- Request
22 61 CC - Service 22
DID 61CC - Module
720 - Every
30 s - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2024 to 2026.
Total months at last service POLESTAR_TOT_MONTHS_LAST
- Request
22 61 CC - Service 22
DID 61CC - Module
720 - Every
30 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
(val × 6)- Range
- 0 to 393210
- Unit
- Raw value
In testing for 2024 to 2026.
Traction control switch indicator POLESTAR_DTSC_SWITCH
- Request
22 2B 05 - Service 22
DID 2B05 - Module
760 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 64 − 1)- Range
- -1 to 2.98
- Unit
- Number
In testing for 2024 to 2026.
Transmission fixed lock-up POLESTAR_FIXED_LOCK_UP
- Request
22 1E 24 - Service 22
DID 1E24 - Module
7E1 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2024 to 2026.
Transmission kickdown POLESTAR_KICKDOWN
- Request
22 DC E4 - Service 22
DID DCE4 - Module
7E1 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2024 to 2026.
Transmission line pressure solenoid current POLESTAR_LINEAR_P_SOLENOID_SLT
- Request
22 1E 40 - Service 22
DID 1E40 - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2024 to 2026.
Transmission line pressure solenoid current POLESTAR_LINEAR_P_SOLENOID_SLT_CURRENT
- Request
22 DA 4A - Service 22
DID DA4A - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2024 to 2026.
Transmission line pressure solenoid current, requested POLESTAR_LINEAR_P_SOLENOID
- Request
22 1E 1E - Service 22
DID 1E1E - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2024 to 2026.
Transmission line pressure solenoid current, requested POLESTAR_LINEAR_P_SOLENOID_SLT_REQ
- Request
22 DA 49 - Service 22
DID DA49 - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2024 to 2026.
Transmission linear pressure solenoid SL1 current POLESTAR_LINEAR_P_SOLENOID_SL1
- Request
22 DA 4E - Service 22
DID DA4E - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2024 to 2026.
Transmission linear pressure solenoid SL1, requested, current POLESTAR_LINEAR_P_SOLENOID_SL1_REQ
- Request
22 DA 4D - Service 22
DID DA4D - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2024 to 2026.
Transmission linear pressure solenoid SL2 current POLESTAR_LINEAR_P_SOLENOID_SL2
- Request
22 DA 50 - Service 22
DID DA50 - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2024 to 2026.
Transmission linear pressure solenoid SL2, requested, current POLESTAR_LINEAR_P_SOLENOID_SL2_REQ
- Request
22 DA 4F - Service 22
DID DA4F - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2024 to 2026.
Transmission linear pressure solenoid SL3 current POLESTAR_LINEAR_P_SOLENOID_SL3
- Request
22 DA 52 - Service 22
DID DA52 - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2024 to 2026.
Transmission linear pressure solenoid SL3, requested, current POLESTAR_LINEAR_P_SOLENOID_SL3_REQ
- Request
22 DA 51 - Service 22
DID DA51 - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2024 to 2026.
Transmission linear pressure solenoid SLB1, requested, current POLESTAR_LINEAR_P_SOLENOID_SLB1_REQ
- Request
22 1E 45 - Service 22
DID 1E45 - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2024 to 2026.
Transmission linear pressure solenoid SLC1 current POLESTAR_LINEAR_P_SOLENOID_SLC1
- Request
22 1E 48 - Service 22
DID 1E48 - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2024 to 2026.
Transmission linear pressure solenoid SLC1, requested, current POLESTAR_LINEAR_P_SOLENOID_SLC1_REQ
- Request
22 1E 42 - Service 22
DID 1E42 - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2024 to 2026.
Transmission linear pressure solenoid SLC2 current POLESTAR_LINEAR_P_SOLENOID_SLC2
- Request
22 1E 49 - Service 22
DID 1E49 - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2024 to 2026.
Transmission linear pressure solenoid SLC2, requested, current POLESTAR_LINEAR_P_SOLENOID_SLC2_REQ
- Request
22 1E 43 - Service 22
DID 1E43 - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2024 to 2026.
Transmission linear pressure solenoid SLC3 current POLESTAR_LINEAR_P_SOLENOID_SLC3
- Request
22 1E 4A - Service 22
DID 1E4A - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2024 to 2026.
Transmission linear pressure solenoid SLC3, requested, current POLESTAR_LINEAR_P_SOLENOID_SLC3_REQ
- Request
22 1E 44 - Service 22
DID 1E44 - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2024 to 2026.
Transmission lock-up function POLESTAR_LOCK_UP_FUNCTION
- Request
22 DA 3C - Service 22
DID DA3C - Module
7E1 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 3 − 0.333333)- Range
- -0.333 to 84.66
- Unit
- Number
In testing for 2024 to 2026.
Transmission selector POLESTAR_SELECTOR
- Request
22 DC EA - Service 22
DID DCEA - Module
7E1 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127
- Unit
- Number
In testing for 2024 to 2026.
Transmission solenoid S1 status POLESTAR_SOLENOID_S1_STAT
- Request
22 DD 89 - Service 22
DID DD89 - Module
7E1 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2024 to 2026.
Transmission solenoid S2 status POLESTAR_SOLENOID_S2_STAT
- Request
22 DD 8A - Service 22
DID DD8A - Module
7E1 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2024 to 2026.
Transmission start lock - start approved POLESTAR_START_LOCK_START
- Request
22 DF 08 - Service 22
DID DF08 - Module
7E1 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 255)- Range
- 0 to 1
- Unit
- Number
In testing for 2024 to 2026.
Transmission torque POLESTAR_TQ
- Request
22 DD 8D - Service 22
DID DD8D - Module
7E1 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 N·m
- Unit
- N·m
In testing for 2024 to 2026.
Transmission torque limiting POLESTAR_TQ_LIMITING
- Request
22 DC F0 - Service 22
DID DCF0 - Module
7E1 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 N·m
- Unit
- N·m
In testing for 2024 to 2026.
Trip 1 POLESTAR_TRIP_1
- Request
22 D9 36 - Service 22
DID D936 - Module
720 - Every
30 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 km
- Unit
- km
In testing for 2024 to 2026.
Trip 2 POLESTAR_TRIP_2
- Request
22 D9 37 - Service 22
DID D937 - Module
720 - Every
30 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 km
- Unit
- km
In testing for 2024 to 2026.
Turbo bypass valve opened POLESTAR_TURBO_BYPASS_VLV
- Request
22 D9 EE - Service 22
DID D9EE - Module
D016 → 1EC60E80 - Every
1 s - Testing
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2024 to 2026.
Turbo control valve wastegate POLESTAR_TURBO_CTRL_VLV_WASTEGATE
- Request
22 DC 10 - Service 22
DID DC10 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 100 ÷ 8191)- Range
- 0 to 800 %
- Unit
- %
In testing for 2024 to 2026.
Turbo control valve, bypass or variable nozzle POLESTAR_TURBO_CTRL_VLV
- Request
22 DC 00 - Service 22
DID DC00 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 100 ÷ 8191)- Range
- 0 to 800 %
- Unit
- %
In testing for 2024 to 2026.
Twilight sensor POLESTAR_TWILIGHT_SENS
- Request
22 41 2A - Service 22
DID 412A - Module
726 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 2024 to 2026.
Wastegate position POLESTAR_WASTEGATE_POS
- Request
22 DC 80 - Service 22
DID DC80 - Module
D016 → 1EC60E80 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2024 to 2026.
Water cooled condenser outlet sensor temperature POLESTAR_WATER_COOLED_T
- Request
22 EE 40 - Service 22
DID EE40 - Module
D016 → 1EC60E80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.14)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2024 to 2026.
Water temperature POLESTAR_WATER_T_MS_CAN
- Request
22 F4 05 - Service 22
DID F405 - Module
7E3 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2024 to 2026.
Yaw rate sensor offset POLESTAR_YAW_RATE_SENS_OFFSET
- Request
22 EE 03 - Service 22
DID EE03 - Module
760 - Every
250 ms - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 3500)- Range
- 0 to 18.72
- Unit
- Raw value
In testing for 2024 to 2026.
Yaw rate signal POLESTAR_YAW_RATE_SIG
- Request
22 2B 0B - Service 22
DID 2B0B - Module
760 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 5)- Range
- -6553 to 6553
- Unit
- Raw value
In testing for 2024 to 2026.