Connectable parameters
The Porsche Macan Electric has 11 Connectables, parameters that Pelican can monitor automatically.
● Confirmed◆ In testing○ Supported× Not supported
Speed
Vehicle speed VSSSAE J1979Confirmed
Pelican can show this parameter as the speed.
- Request
01 0D - Service 01
PID 0D - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 km/h
- Unit
- km/h
Confirmed for 2025. Supported for 2024.
Electric range
Range remaining MACANEV_RANGEConfirmed
Pelican can show this parameter as the electric range.
- Request
22 2A B6 - Service 22
DID 2AB6 - Module
710 → 77A - Every
5 s - Testing for 2026
Example reply from a 2025 Porsche Macan Electric.
Bits 0 to 15 of the reply, 16 bits.
0x003A = 58 → 58 mi
- Formula
val- Range
- 0 to 65535 mi
- Unit
- mi
Confirmed for 2024 to 2025. In testing for 2026.
Front left tire pressure
Front left tire pressure MACANEV_TP_FLConfirmed
Pelican can show this parameter as the front left tire pressure.
- Request
22 18 A1 - Service 22
DID 18A1 - Module
70B → 775 - Every
5 s - Testing for 2026
Example reply from a 2025 Porsche Macan Electric.
Bits 40 to 47 of the reply, 8 bits.
0x76 = 118 → (118 ÷ 40) = 2.95 bar
- Formula
(val ÷ 40)- Range
- 0 to 6.375 bar
- Unit
- bar
Confirmed for 2024 to 2025. In testing for 2026.
Front right tire pressure
Front right tire pressure MACANEV_TP_FRConfirmed
Pelican can show this parameter as the front right tire pressure.
- Request
22 18 A0 - Service 22
DID 18A0 - Module
70B → 775 - Every
5 s - Testing for 2026
Example reply from a 2025 Porsche Macan Electric.
Bits 40 to 47 of the reply, 8 bits.
0x76 = 118 → (118 ÷ 40) = 2.95 bar
- Formula
(val ÷ 40)- Range
- 0 to 6.375 bar
- Unit
- bar
Confirmed for 2024 to 2025. In testing for 2026.
Rear left tire pressure
Rear left tire pressure MACANEV_TP_RLConfirmed
Pelican can show this parameter as the rear left tire pressure.
- Request
22 18 A2 - Service 22
DID 18A2 - Module
70B → 775 - Every
5 s - Testing for 2026
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 40)- Range
- 0 to 6.375 bar
- Unit
- bar
Confirmed for 2024 to 2025. In testing for 2026.
Rear right tire pressure
Rear right tire pressure MACANEV_TP_RRConfirmed
Pelican can show this parameter as the rear right tire pressure.
- Request
22 18 A3 - Service 22
DID 18A3 - Module
70B → 775 - Every
5 s - Testing for 2026
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 40)- Range
- 0 to 6.375 bar
- Unit
- bar
Confirmed for 2024 to 2025. In testing for 2026.
CheckEngineLightOn
Malfunction indicator lamp MILSAE J1979Confirmed
The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.
Pelican can show this parameter as the checkEngineLightOn.
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 0 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2025. Supported for 2024.
Engine coolant temperature
Engine coolant temperature ECTSAE J1979Confirmed
Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.
Pelican can show this parameter as the engine coolant temperature.
- Request
01 05 - Service 01
PID 05 - Module
7E0 → 7E8 - Every
500 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2025. Supported for 2024.
Engine load
Calculated engine load LOAD_PCTSAE J1979Confirmed
Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.
Pelican can show this parameter as the engine load.
- Request
01 04 - Service 01
PID 04 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2025. Supported for 2024.
Starter battery voltage
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Request
01 42 - Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65535 V
- Unit
- V
Confirmed for 2025. Supported for 2024.
StoredDTCCount
Number of DTCs stored in this ECU DTC_CNTSAE J1979Confirmed
Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.
Pelican can show this parameter as the storedDTCCount.
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bits 1 to 7 of the reply, 7 bits.
- Formula
val- Range
- 0 to 127
- Unit
- Number
Confirmed for 2025. Supported for 2024.