Engine parameters
The Ram 1500 Classic has 132 engine parameters.
● Confirmed◆ In testing○ Supported× Not supported
Absolute load value LOAD_ABSSAE J1979Confirmed
- Request
01 43 - Service 01
PID 43 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 25700 %
- Unit
- %
Confirmed for 2012 to 2013, 2016 to 2026. Supported for 2015.
Actual engine torque TQ_ACTSAE J1979Confirmed
- Request
01 62 - Service 01
PID 62 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 125)- Range
- -125 to 130 %
- Unit
- %
Confirmed for 2019 to 2026. Supported for 2017.
Air conditioning high side pressure 1500_AC_HIGH_SIDE_P
- Request
21 A7 - Service 21
PID A7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val ÷ 55)- Range
- 0 to 1191 psi
- Unit
- psi
In testing for 2009 to 2012, 2014 to 2016, 2018, 2020, 2022 to 2024. Not supported for 2013, 2017, 2019, 2021.
Air conditioning high side pressure 1500_AC_HIGH_SIDE_P_2Confirmed
- Request
22 03 29 - Service 22
DID 0329 - Module
7E0 → 7E8 - Every
1 s - Testing for 2009 to 2012, 2014 to 2018, 2020, 2022 to 2026
Example reply from a 2021 Ram 1500 Classic.
Bits 0 to 7 of the reply, 8 bits.
0x3C = 60 → (60 × 14) = 840 kPa
- Formula
(val × 14)- Range
- 0 to 3570 kPa
- Unit
- kPa
Confirmed for 2013, 2019, 2021. In testing for 2009 to 2012, 2014 to 2016, 2018, 2020, 2022 to 2024. Not supported for 2017.
Air flow rate from mass air flow sensor MAFSAE J1979Confirmed
Pelican can show this parameter as the mass air flow.
- Request
01 10 - Service 01
PID 10 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 g/s
- Unit
- g/s
Confirmed for 2017, 2025 to 2026. Supported for 2019 to 2023.
Ambient air temperature 1500_AAT
- Request
21 23 - Service 21
PID 23 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023 °F
- Unit
- °F
In testing for 2009 to 2012, 2014 to 2016, 2018, 2020, 2022 to 2024. Not supported for 2013, 2017, 2019, 2021.
Ambient temperature 1500_AAT_2Confirmed
- Request
22 01 27 - Service 22
DID 0127 - Module
7E0 → 7E8 - Every
5 s - Testing for 2009 to 2012, 2014 to 2018, 2020, 2022 to 2026
Example reply from a 2021 Ram 1500 Classic.
Bits 0 to 7 of the reply, 8 bits.
0x59 = 89 → (89 × 9 ÷ 5 − 83) = 77.2 °F
- Formula
(val × 9 ÷ 5 − 83)- Range
- -83 to 376 °F
- Unit
- °F
Confirmed for 2013, 2019, 2021. In testing for 2009 to 2012, 2014 to 2016, 2018, 2020, 2022 to 2024. Not supported for 2017.
AT main cylinder pressure 1500_MAIN_CYL_PConfirmed
- Request
22 50 34 - Service 22
DID 5034 - Module
7E1 → 7E9 - Every
1 s - Testing for 2009 to 2012, 2014 to 2016, 2018, 2020, 2022 to 2026
Example reply from a 2021 Ram 1500 Classic.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → (0 ÷ 10 − 40) = -40 bar
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513 bar
- Unit
- bar
Confirmed for 2013, 2017, 2019, 2021. In testing for 2009 to 2012, 2014 to 2016, 2018, 2020, 2022 to 2024.
Automatic transmission fluid temperature 1500_ATF_T_3RDGEN
- Request
21 18 - Service 21
PID 18 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64 − 40)- Range
- -40 to 983.9843 °F
- Unit
- °F
In testing for 2009 to 2012, 2014 to 2015. Not supported for 2013, 2016 to 2025.
Automatic transmission fluid temperature 1500_ATF_T_3RDGEN_V2
- Request
21 5C - Service 21
PID 5C - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2009 to 2012, 2014 to 2016, 2018, 2020, 2022 to 2024. Not supported for 2013, 2017, 2019, 2021.
Automatic transmission fluid temperature 1500_ATF_T_4THGENConfirmed
- Request
22 04 FE - Service 22
DID 04FE - Module
DA18 → 18 - Every
1 s - Testing for 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2025. In testing for 2026.
Barometric pressure 1500_BAROMETRIC_PConfirmed
- Request
22 01 09 - Service 22
DID 0109 - Module
7E0 → 7E8 - Every
1 s - Testing for 2009 to 2012, 2014 to 2018, 2020, 2022 to 2026
Example reply from a 2021 Ram 1500 Classic.
Bits 0 to 15 of the reply, 16 bits.
0x01E6 = 486 → (486 ÷ 5) = 97.2 kPa
- Formula
(val ÷ 5)- Range
- 0 to 13107 kPa
- Unit
- kPa
Confirmed for 2013, 2019, 2021. In testing for 2009 to 2012, 2014 to 2016, 2018, 2020, 2022 to 2024. Not supported for 2017.
Barometric pressure BAROSAE J1979Confirmed
Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.
- Request
01 33 - Service 01
PID 33 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2012 to 2013, 2016, 2018 to 2026. Supported for 2014 to 2015, 2017.
Boost pressure sensor A BP_A_ACTSAE J1979Confirmed
Actual turbocharger/supercharger A boost pressure.
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bits 24 to 39 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.96875 kPa
- Unit
- kPa
Confirmed for 2025 to 2026.
Boost pressure sensor B BP_B_ACTSAE J1979Confirmed
Actual turbocharger/supercharger B boost pressure.
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bits 56 to 71 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.96875 kPa
- Unit
- kPa
Confirmed for 2025 to 2026.
Calculated engine load LOAD_PCTSAE J1979Confirmed
Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.
Pelican can show this parameter as the engine load.
- Request
01 04 - Service 01
PID 04 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2012 to 2013, 2015 to 2026. Supported for 2014.
Cam crank difference 1500_CAM_CRANK_DIFF
- Request
22 05 9E - Service 22
DID 059E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 °
- Unit
- °
In testing for 2009 to 2012, 2014 to 2016, 2018, 2020, 2022 to 2024. Not supported for 2013, 2017, 2019, 2021.
Catalyst modeled temperature 1500_CAT_MODEL_TConfirmed
- Request
22 01 2B - Service 22
DID 012B - Module
7E0 → 7E8 - Every
5 s - Testing for 2009 to 2012, 2014 to 2018, 2020, 2022 to 2026
Example reply from a 2021 Ram 1500 Classic.
Bits 0 to 15 of the reply, 16 bits.
0x01C2 = 450 → 450 °C
- Formula
val- Range
- 0 to 1000 °C
- Unit
- °C
Confirmed for 2013, 2019, 2021. In testing for 2009 to 2012, 2014 to 2016, 2018, 2020, 2022 to 2024. Not supported for 2017.
Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed
- Request
01 3C - Service 01
PID 3C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
Confirmed for 2012 to 2013, 2016, 2018 to 2026. Supported for 2014 to 2015, 2017.
Catalyst temperature bank 2, sensor 1 CATEMP21SAE J1979Confirmed
- Request
01 3D - Service 01
PID 3D - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
Confirmed for 2012 to 2013, 2016, 2018 to 2026. Supported for 2014 to 2015, 2017.
Commanded boost pressure A BP_A_CMDSAE J1979Confirmed
Turbocharger/supercharger A commanded boost pressure.
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.96875 kPa
- Unit
- kPa
Confirmed for 2025 to 2026.
Commanded boost pressure B BP_B_CMDSAE J1979Confirmed
Turbocharger/supercharger B commanded boost pressure.
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bits 40 to 55 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.96875 kPa
- Unit
- kPa
Confirmed for 2025 to 2026.
Commanded EGR EGR_PCTSAE J1979Confirmed
- Request
01 2C - Service 01
PID 2C - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2025 to 2026. Supported for 2019, 2021 to 2023.
Commanded equivalence ratio EQ_RATSAE J1979Confirmed
Fuel systems that utilize conventional oxygen sensor display the inverse of the commanded open loop equivalence ratio (also known as lambda) while the fuel control system is in open loop. Will indicate 1.000 while in closed-loop fuel.
Pelican can show this parameter as the commanded lambda.
- Request
01 44 - Service 01
PID 44 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2 ÷ 65535)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2012 to 2013, 2015 to 2016, 2018 to 2026. Supported for 2017.
Commanded evaporative purge EVAP_PCTSAE J1979Confirmed
- Request
01 2E - Service 01
PID 2E - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2012 to 2013, 2016, 2018 to 2026. Supported for 2014 to 2015, 2017.
Commanded throttle actuator control TAC_PCTSAE J1979Confirmed
- Request
01 4C - Service 01
PID 4C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2012 to 2013, 2016, 2018 to 2026.
Coolant temperature 1500_ECT_ECU
Pelican can show this parameter as the engine coolant temperature.
- Request
22 10 03 - Service 22
DID 1003 - Module
DA10 → 10 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2 ÷ 100 − 40)- Range
- -40 to 200 °C
- Unit
- °C
In testing for 2026. Not supported for 2025.
EGR error EGR_ERRSAE J1979Confirmed
- Request
01 2D - Service 01
PID 2D - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2025 to 2026. Supported for 2019, 2021 to 2023.
Engine coolant temperature ECTSAE J1979Confirmed
Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.
Pelican can show this parameter as the engine coolant temperature.
- Request
01 05 - Service 01
PID 05 - Module
7E0 → 7E8 - Every
500 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2012 to 2013, 2015 to 2026. Supported for 2014.
Engine Friction - Percent Torque TQ_FRSAE J1979Confirmed
- Request
01 8E - Service 01
PID 8E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 125)- Range
- -125 to 130 %
- Unit
- %
Confirmed for 2019 to 2026.
Engine oil pressure 1500_EOPConfirmed
- Request
22 02 2A - Service 22
DID 022A - Module
7E0 → 7E8 - Every
1 s - Testing for 2009 to 2012, 2014 to 2018, 2020, 2022 to 2026
Example reply from a 2021 Ram 1500 Classic.
Bits 0 to 7 of the reply, 8 bits.
0x33 = 51 → (51 × 29 ÷ 50) = 29.58 psi
- Formula
(val × 29 ÷ 50)- Range
- 0 to 147.8999 psi
- Unit
- psi
Confirmed for 2013, 2019, 2021. In testing for 2009 to 2012, 2014 to 2016, 2018, 2020, 2022 to 2024. Not supported for 2017.
Engine oil temperature 1500_EOT_212DConfirmed
Pelican can show this parameter as the engine oil temperature.
- Request
21 2D - Service 21
PID 2D - Module
7E0 → 7E8 - Every
5 s - Testing for 2009 to 2012, 2014 to 2018, 2020, 2022 to 2026
Example reply from a 2021 Ram 1500 Classic.
Bits 56 to 63 of the reply, 8 bits.
0x99 = 153 → (153 × 9 ÷ 5 − 83) = 192.4 °F
- Formula
(val × 9 ÷ 5 − 83)- Range
- -83 to 376 °F
- Unit
- °F
Confirmed for 2013, 2019, 2021. In testing for 2009 to 2012, 2014 to 2016, 2018, 2020, 2022 to 2024. Not supported for 2017.
Engine oil temperature 1500_EOT_21D2Confirmed
Pelican can show this parameter as the engine oil temperature.
- Request
21 D2 - Service 21
PID D2 - Module
7E0 → 7E8 - Every
5 s - Testing for 2009 to 2018, 2020, 2022 to 2026
Example reply from a 2021 Ram 1500 Classic.
Bits 56 to 63 of the reply, 8 bits.
0x00 = 0 → (0 − 64) = -64 °C
- Formula
(val − 64)- Range
- -64 to 191 °C
- Unit
- °C
Confirmed for 2019, 2021. In testing for 2009 to 2012, 2014 to 2016, 2018, 2020, 2022 to 2024. Not supported for 2013, 2017.
Engine oil temperature EOTSAE J1979Confirmed
Pelican can show this parameter as the engine oil temperature.
- Request
01 5C - Service 01
PID 5C - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 210 °C
- Unit
- °C
Confirmed for 2025 to 2026. Supported for 2017, 2020 to 2023.
Engine operational status 1500_ENGINE_STATUSConfirmed
- Request
22 10 02 - Service 22
DID 1002 - Module
DA10 → 10 - Every
30 s - Testing for 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2025. In testing for 2026.
Engine reference torque TQ_REFSAE J1979Confirmed
- Request
01 63 - Service 01
PID 63 - Module
7E0 → 7E8 - Every
86400 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 N·m
- Unit
- N·m
Confirmed for 2019 to 2026. Supported for 2017.
Engine RPM 1500_RPMConfirmed
- Request
22 10 00 - Service 22
DID 1000 - Module
DA10 → 10 - Every
1 s - Testing for 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383 rpm
- Unit
- rpm
Confirmed for 2025. In testing for 2026.
Engine RPM RPMSAE J1979Confirmed
- Request
01 0C - Service 01
PID 0C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383.75 rpm
- Unit
- rpm
Confirmed for 2012 to 2013, 2016 to 2026. Supported for 2014 to 2015.
Evap system vapor pressure EVAP_VPSAE J1979Confirmed
The pressure signal is normally obtained from a sensor located in the fuel tank or a sensor in an evaporative system vapor line.
- Request
01 32 - Service 01
PID 32 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 4000)- Range
- -8192 to 8191.75 kPa
- Unit
- kPa
Confirmed for 2012 to 2013, 2016, 2018 to 2026. Supported for 2014 to 2015, 2017.
Exhaust camshaft 1 to crankshaft offset 1500_EXH_CAM_1_OFFSET
- Request
22 06 1B - Service 22
DID 061B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 2009 to 2012, 2014 to 2016, 2018, 2020, 2022 to 2024. Not supported for 2013, 2017, 2019, 2021.
Exhaust Gas Recirculation Temp Sensor A (Bank 1, Sensor 1) EGRTASAE J1979Confirmed
- Request
01 6B - Service 01
PID 6B - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2025 to 2026. Supported for 2019.
Exhaust Gas Recirculation Temp Sensor B (Bank 2, Sensor 1) EGRTBSAE J1979Confirmed
- Request
01 6B - Service 01
PID 6B - Module
7E0 → 7E8 - Every
250 ms
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2025 to 2026. Supported for 2019.
Exhaust Gas Recirculation Temp Sensor C (Bank 1, Sensor 2) EGRTCSAE J1979Confirmed
- Request
01 6B - Service 01
PID 6B - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2025 to 2026. Supported for 2019.
Exhaust Gas Recirculation Temp Sensor D (Bank 2, Sensor 2) EGRTDSAE J1979Confirmed
- Request
01 6B - Service 01
PID 6B - Module
7E0 → 7E8 - Every
250 ms
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2025 to 2026. Supported for 2019.
Fuel pressure FPSAE J1979Confirmed
- Request
01 0A - Service 01
PID 0A - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 3)- Range
- 0 to 765 kPa
- Unit
- kPa
Confirmed for 2013, 2016, 2018 to 2020, 2023, 2025 to 2026. Supported for 2015, 2017, 2021 to 2022.
Fuel rail pressure FRPSAE J1979Confirmed
Fuel rail pressure at the engine when the reading is referenced to atmosphere (gage pressure).
- Request
01 23 - Service 01
PID 23 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 kPa
- Unit
- kPa
Confirmed for 2025 to 2026. Supported for 2020 to 2023.
Fuel rail pressure commanded 1500_RAIL_PRESS_CMD
- Request
22 19 46 - Service 22
DID 1946 - Module
DA10 → 10 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 20)- Range
- 0 to 3000 bar
- Unit
- bar
In testing for 2026. Not supported for 2025.
Fuel rail pressure measured 1500_RAIL_PRESS
- Request
22 19 47 - Service 22
DID 1947 - Module
DA10 → 10 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 20)- Range
- 0 to 3000 bar
- Unit
- bar
In testing for 2026. Not supported for 2025.
IAT post-intercooler 1500_IAT_TURBO
- Request
22 19 35 - Service 22
DID 1935 - Module
DA10 → 10 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2 ÷ 100 − 40)- Range
- -40 to 200 °C
- Unit
- °C
In testing for 2026. Not supported for 2025.
Injector pulse width, cylinder 1 1500_INJ_WIDTH_CYL_1Confirmed
- Request
22 02 34 - Service 22
DID 0234 - Module
7E0 → 7E8 - Every
1 s - Testing for 2009 to 2012, 2014 to 2018, 2020, 2022 to 2026
Example reply from a 2021 Ram 1500 Classic.
Bits 0 to 31 of the reply, 32 bits.
0x00000130 = 304 → (304 ÷ 1000) = 0.304 ms
- Formula
(val ÷ 1000)- Range
- 0 to 4294967 ms
- Unit
- ms
Confirmed for 2013, 2019, 2021. In testing for 2009 to 2012, 2014 to 2016, 2018, 2020, 2022 to 2024. Not supported for 2017.
Injector pulse width, cylinder 2 1500_INJ_WIDTH_CYL_2Confirmed
- Request
22 02 35 - Service 22
DID 0235 - Module
7E0 → 7E8 - Every
1 s - Testing for 2009 to 2012, 2014 to 2018, 2020, 2022 to 2026
Example reply from a 2021 Ram 1500 Classic.
Bits 0 to 31 of the reply, 32 bits.
0x00000500 = 1280 → (1280 ÷ 1000) = 1.28 ms
- Formula
(val ÷ 1000)- Range
- 0 to 4294967 ms
- Unit
- ms
Confirmed for 2013, 2019, 2021. In testing for 2009 to 2012, 2014 to 2016, 2018, 2020, 2022 to 2024. Not supported for 2017.
Injector pulse width, cylinder 3 1500_INJ_WIDTH_CYL_3Confirmed
- Request
22 02 36 - Service 22
DID 0236 - Module
7E0 → 7E8 - Every
1 s - Testing for 2009 to 2012, 2014 to 2018, 2020, 2022 to 2026
Example reply from a 2021 Ram 1500 Classic.
Bits 0 to 31 of the reply, 32 bits.
0x00000130 = 304 → (304 ÷ 1000) = 0.304 ms
- Formula
(val ÷ 1000)- Range
- 0 to 4294967 ms
- Unit
- ms
Confirmed for 2013, 2019, 2021. In testing for 2009 to 2012, 2014 to 2016, 2018, 2020, 2022 to 2024. Not supported for 2017.
Injector pulse width, cylinder 4 1500_INJ_WIDTH_CYL_4Confirmed
- Request
22 02 37 - Service 22
DID 0237 - Module
7E0 → 7E8 - Every
1 s - Testing for 2009 to 2012, 2014 to 2018, 2020, 2022 to 2026
Example reply from a 2021 Ram 1500 Classic.
Bits 0 to 31 of the reply, 32 bits.
0x00000130 = 304 → (304 ÷ 1000) = 0.304 ms
- Formula
(val ÷ 1000)- Range
- 0 to 4294967 ms
- Unit
- ms
Confirmed for 2013, 2019, 2021. In testing for 2009 to 2012, 2014 to 2016, 2018, 2020, 2022 to 2024. Not supported for 2017.
Intake air temperature IATSAE J1979Confirmed
- Request
01 0F - Service 01
PID 0F - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2012 to 2013, 2016, 2018 to 2026. Supported for 2014 to 2015, 2017.
Intake air temperature, bank 1, sensor 1 IAT_11SAE J1979Confirmed
- Request
01 68 - Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2023, 2025 to 2026.
Intake air temperature, bank 1, sensor 2 IAT_12SAE J1979Confirmed
- Request
01 68 - Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2023, 2025 to 2026.
Intake air temperature, bank 1, sensor 3 IAT_13SAE J1979Confirmed
- Request
01 68 - Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2023, 2025 to 2026.
Intake air temperature, bank 2, sensor 2 IAT_22SAE J1979Confirmed
- Request
01 68 - Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2025 to 2026. Supported for 2023.
Intake camshaft 1 to crankshaft offset 1500_INT_CAM_1_OFFSETConfirmed
- Request
22 06 C2 - Service 22
DID 06C2 - Module
7E0 → 7E8 - Every
1 s - Testing for 2009 to 2012, 2014 to 2018, 2020, 2022 to 2026
Example reply from a 2021 Ram 1500 Classic.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0001 = 1 → (1 ÷ 10) = 0.1 °
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 °
- Unit
- °
Confirmed for 2013, 2019, 2021. In testing for 2009 to 2012, 2014 to 2016, 2018, 2020, 2022 to 2024. Not supported for 2017.
Intake manifold absolute pressure MAPSAE J1979Confirmed
- Request
01 0B - Service 01
PID 0B - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2012 to 2013, 2016, 2018 to 2026. Supported for 2014 to 2015, 2017.
Intake manifold air pressure 1500_MAPConfirmed
- Request
22 01 74 - Service 22
DID 0174 - Module
7E0 → 7E8 - Every
1 s - Testing for 2009 to 2012, 2014 to 2016, 2018, 2020, 2022 to 2026
Example reply from a 2021 Ram 1500 Classic.
Bits 0 to 15 of the reply, 16 bits.
0x0069 = 105 → (105 ÷ 5) = 21 kPa
- Formula
(val ÷ 5)- Range
- 0 to 13107 kPa
- Unit
- kPa
Confirmed for 2013, 2017, 2019, 2021. In testing for 2009 to 2012, 2014 to 2016, 2018, 2020, 2022 to 2024.
Intake manifold air temperature 1500_IAT_01FFConfirmed
- Request
22 01 FF - Service 22
DID 01FF - Module
7E0 → 7E8 - Every
5 s - Testing for 2009 to 2012, 2014 to 2018, 2020, 2022 to 2026
Example reply from a 2021 Ram 1500 Classic.
Bits 8 to 15 of the reply, 8 bits.
0x63 = 99 → (99 − 64) = 35 °C
- Formula
(val − 64)- Range
- -64 to 191 °C
- Unit
- °C
Confirmed for 2013, 2019, 2021. In testing for 2009 to 2012, 2014 to 2016, 2018, 2020, 2022 to 2024. Not supported for 2017.
Intake manifold air temperature 1500_IAT_70B8
- Request
22 70 B8 - Service 22
DID 70B8 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0198412698 − 40)- Range
- -40 to 1260.2976 °C
- Unit
- °C
In testing for 2009 to 2012, 2014 to 2016, 2018, 2020, 2022 to 2024. Not supported for 2013, 2017, 2019, 2021.
Knock sensor 1 1500_KNOCK_SENS_1Confirmed
- Request
22 01 A9 - Service 22
DID 01A9 - Module
7E0 → 7E8 - Every
1 s - Testing for 2009 to 2012, 2014 to 2018, 2020, 2022 to 2026
Example reply from a 2021 Ram 1500 Classic.
Bits 0 to 15 of the reply, 16 bits.
0x1300 = 4864 → (4864 ÷ 13107) = 0.371099 V
- Formula
(val ÷ 13107)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2013, 2019, 2021. In testing for 2009 to 2012, 2014 to 2016, 2018, 2020, 2022 to 2024. Not supported for 2017.
Knock sensor 2 1500_KNOCK_SENS_2Confirmed
- Request
22 01 AA - Service 22
DID 01AA - Module
7E0 → 7E8 - Every
1 s - Testing for 2009 to 2012, 2014 to 2018, 2020, 2022 to 2026
Example reply from a 2021 Ram 1500 Classic.
Bits 0 to 15 of the reply, 16 bits.
0x1300 = 4864 → (4864 ÷ 13107) = 0.371099 V
- Formula
(val ÷ 13107)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2013, 2019, 2021. In testing for 2009 to 2012, 2014 to 2016, 2018, 2020, 2022 to 2024. Not supported for 2017.
Line pressure 1500_LINE_P
- Request
21 17 - Service 21
PID 17 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 psi
- Unit
- psi
In testing for 2009 to 2012, 2014 to 2016, 2018, 2020, 2022 to 2024. Not supported for 2013, 2017, 2019, 2021.
Line pressure duty cycle 1500_LINE_P_DUTY
- Request
21 17 - Service 21
PID 17 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 655)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2012, 2014 to 2016, 2018, 2020, 2022 to 2024. Not supported for 2013, 2017, 2019, 2021.
Long term fuel trim (bank 1) LONGFT1SAE J1979Confirmed
- Request
01 07 - Service 01
PID 07 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2012 to 2013, 2016, 2018 to 2026. Supported for 2014 to 2015, 2017.
Long term fuel trim (bank 2) LONGFT2SAE J1979Confirmed
- Request
01 09 - Service 01
PID 09 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2012 to 2013, 2016, 2018 to 2026. Supported for 2014 to 2015, 2017.
Long term secondary O2 sensor fuel trim (bank 1) LGSO2FT1SAE J1979Confirmed
- Request
01 56 - Service 01
PID 56 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2025 to 2026.
Long term secondary O2 sensor fuel trim (bank 2) LGSO2FT2SAE J1979Confirmed
- Request
01 58 - Service 01
PID 58 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2025 to 2026.
Low side coolant temperature 1500_LOW_SIDE_ECTConfirmed
- Request
22 12 C9 - Service 22
DID 12C9 - Module
7E0 → 7E8 - Every
5 s - Testing for 2009 to 2018, 2020, 2022 to 2026
Example reply from a 2021 Ram 1500 Classic.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → (0 − 64) = -64 °C
- Formula
(val − 64)- Range
- -64 to 191 °C
- Unit
- °C
Confirmed for 2019, 2021. In testing for 2009 to 2012, 2014 to 2016, 2018, 2020, 2022 to 2024. Not supported for 2013, 2017.
Mass airflow sensor temperature 1500_MAF_TEMP
- Request
22 19 3F - Service 22
DID 193F - Module
DA10 → 10 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2 ÷ 100 − 40)- Range
- -40 to 200 °C
- Unit
- °C
In testing for 2026. Not supported for 2025.
Multi-displacement system active 1500_MDS_ACTIVEConfirmed
- Request
22 0E CA - Service 22
DID 0ECA - Module
7E0 → 7E8 - Every
1 s - Testing for 2009 to 2012, 2014 to 2018, 2020, 2022 to 2026
Example reply from a 2021 Ram 1500 Classic.
Bit 4 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2013, 2019, 2021. In testing for 2009 to 2012, 2014 to 2016, 2018, 2020, 2022 to 2024. Not supported for 2017.
Power take off (PTO) status PTO_STATSAE J1979Confirmed
- Request
01 1E - Service 01
PID 1E - Module
7E0 → 7E8 - Every
1 s
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2012 to 2013. Supported for 2019.
Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed
Correction being used by the closed-loop fuel algorithm.
Pelican can show this parameter as the short term fuel trim.
- Request
01 06 - Service 01
PID 06 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2012 to 2013, 2016, 2018 to 2026. Supported for 2014 to 2015, 2017.
Short term fuel trim (bank 2) SHRTFT2SAE J1979Confirmed
Correction being used by the closed-loop fuel algorithm.
Pelican can show this parameter as the short term fuel trim.
- Request
01 08 - Service 01
PID 08 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2012 to 2013, 2016, 2018 to 2026. Supported for 2014 to 2015, 2017.
Short term knock retard 1500_SHORT_TERM_KNOCK
- Request
22 01 AE - Service 22
DID 01AE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2)- Range
- 0 to 32767.5 °
- Unit
- °
In testing for 2009 to 2012, 2014 to 2016, 2018, 2020, 2022 to 2024. Not supported for 2013, 2017, 2019, 2021.
Throttle inlet air temperature filtered 1500_THROTTLE_INLET_AIR_TConfirmed
- Request
22 14 B1 - Service 22
DID 14B1 - Module
7E0 → 7E8 - Every
5 s - Testing for 2009 to 2018, 2020, 2022 to 2026
Example reply from a 2021 Ram 1500 Classic.
Bits 8 to 15 of the reply, 8 bits.
0x5D = 93 → (93 − 64) = 29 °C
- Formula
(val − 64)- Range
- -64 to 191 °C
- Unit
- °C
Confirmed for 2019, 2021. In testing for 2009 to 2012, 2014 to 2016, 2018, 2020, 2022 to 2024. Not supported for 2013, 2017.
Throttle inlet air temperature raw 1500_THROTTLE_INLET_AIR_T_RAWConfirmed
- Request
22 14 B3 - Service 22
DID 14B3 - Module
7E0 → 7E8 - Every
5 s - Testing for 2009 to 2018, 2020, 2022 to 2026
Example reply from a 2021 Ram 1500 Classic.
Bits 8 to 15 of the reply, 8 bits.
0x00 = 0 → (0 − 64) = -64 °C
- Formula
(val − 64)- Range
- -64 to 191 °C
- Unit
- °C
Confirmed for 2019, 2021. In testing for 2009 to 2012, 2014 to 2016, 2018, 2020, 2022 to 2024. Not supported for 2013, 2017.
Throttle inlet pressure 1500_THROTTLE_INLET_PConfirmed
- Request
22 12 47 - Service 22
DID 1247 - Module
7E0 → 7E8 - Every
250 ms - Testing for 2009 to 2018, 2020, 2022 to 2026
Example reply from a 2021 Ram 1500 Classic.
Bits 0 to 15 of the reply, 16 bits.
0x3CDA = 15578 → (15578 ÷ 160) = 97.3625 kPa
- Formula
(val ÷ 160)- Range
- 0 to 409.5937 kPa
- Unit
- kPa
Confirmed for 2019, 2021. In testing for 2009 to 2012, 2014 to 2016, 2018, 2020, 2022 to 2024. Not supported for 2013, 2017.
Timing advance SPARKADVSAE J1979Confirmed
Ignition timing spark advance for the first cylinder. Measured in degrees before dead center. Minus is degrees before dead center, positive is degrees after.
- Request
01 0E - Service 01
PID 0E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 64)- Range
- -64 to 63.5 °
- Unit
- °
Confirmed for 2012 to 2013, 2016, 2018 to 2026. Supported for 2014 to 2015, 2017.
Turbo boost pressure 1500_BOOST
- Request
22 19 5A - Service 22
DID 195A - Module
DA10 → 10 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 3276.8)- Range
- -100 to 300 kPa
- Unit
- kPa
In testing for 2026. Not supported for 2025.
Type of fuel currently being used by the vehicle FUEL_TYPSAE J1979Confirmed
- Request
01 51 - Service 01
PID 51 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | GAS | Gasoline/petrol |
2 | METH | Methanol |
3 | ETH | Ethanol |
4 | DSL | Diesel |
5 | LPG | Liquefied petroleum gas |
6 | CNG | Compressed natural gas |
7 | PROP | Propane |
8 | ELEC | Battery/electric |
9 | BI_GAS | Bi-fuel vehicle using gasoline/petrol |
10 | BI_METH | Bi-fuel vehicle using methanol |
11 | BI_ETH | Bi-fuel vehicle using ethanol |
12 | BI_LPG | Bi-fuel vehicle using LPG |
13 | BI_CNG | Bi-fuel vehicle using CNG |
14 | BI_PROP | Bi-fuel vehicle using propane |
15 | BI_ELEC | Bi-fuel vehicle using battery |
16 | BI_MIX | Bi-fuel vehicle using battery and combustion engine for propulsion |
17 | HYB_GAS | Hybrid vehicle using gasoline engine for propulsion |
18 | HYB_ETH | Hybrid vehicle using gasoline engine on ethanol for propulsion |
19 | HYB_DSL | Hybrid vehicle using diesel engine for propulsion |
20 | HYB_ELEC | Hybrid vehicle using battery for propulsion |
21 | HYB_MIX | Hybrid vehicle using battery and combustion engine for propulsion |
22 | HYB_REG | Hybrid vehicle in regeneration mode |
23 | BI_DSL | Bi-fuel vehicle using diesel |
24 | BI_NG | Bi-fuel vehicle using natural gas |
25 | BI_DSL | Bi-fuel vehicle using diesel |
26 | NG | Natural gas |
27 | DSL_CNG | Dual fuel vehicle using diesel and CNG |
28 | DSL_LNG | Dual fuel vehicle using diesel and LNG |
29 | FC_H2 | Fuel cell utilizing hydrogen |
30 | HICE_HHO | Hydrogen Internal Combustion Engine |
31 | KERO | Kerosene |
32 | HFO | Heavy Fuel Oil |
Confirmed for 2013, 2016, 2018 to 2026. Supported for 2017.
Variable oil pump position 1500_OIL_PUMP
- Request
22 19 4F - Service 22
DID 194F - Module
DA10 → 10 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2026. Not supported for 2025.
Variable valve timing oil pressure 1500_VARIABLE_VLV_TIM_OIL_PConfirmed
- Request
22 06 9E - Service 22
DID 069E - Module
7E0 → 7E8 - Every
1 s - Testing for 2009 to 2012, 2014 to 2018, 2020, 2022 to 2026
Example reply from a 2021 Ram 1500 Classic.
Bits 0 to 7 of the reply, 8 bits.
0x31 = 49 → (49 × 4) = 196 kPa
- Formula
(val × 4)- Range
- 0 to 1020 kPa
- Unit
- kPa
Confirmed for 2013, 2019, 2021. In testing for 2009 to 2012, 2014 to 2016, 2018, 2020, 2022 to 2024. Not supported for 2017.
Variable valve timing oil temperature 1500_VARIABLE_VLV_TIM_OIL_TConfirmed
- Request
22 06 9F - Service 22
DID 069F - Module
7E0 → 7E8 - Every
5 s - Testing for 2009 to 2012, 2014 to 2018, 2020, 2022 to 2026
Example reply from a 2021 Ram 1500 Classic.
Bits 0 to 7 of the reply, 8 bits.
0x7F = 127 → (127 − 64) = 63 °C
- Formula
(val − 64)- Range
- -64 to 191 °C
- Unit
- °C
Confirmed for 2013, 2019, 2021. In testing for 2009 to 2012, 2014 to 2016, 2018, 2020, 2022 to 2024. Not supported for 2017.
Wastegate position sensor 1500_WASTEGATE_POS_SENSConfirmed
- Request
22 1F 59 - Service 22
DID 1F59 - Module
7E0 → 7E8 - Every
1 s - Testing for 2009 to 2018, 2020, 2022 to 2026
Example reply from a 2021 Ram 1500 Classic.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → (0 × 61 ÷ 12500) = 0 V
- Formula
(val × 61 ÷ 12500)- Range
- 0 to 319.8107 V
- Unit
- V
Confirmed for 2019, 2021. In testing for 2009 to 2012, 2014 to 2016, 2018, 2020, 2022 to 2024. Not supported for 2013, 2017.
Engine › Internal
Boost bressure A control status BP_ASAE J1979Confirmed
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bits 78 to 79 of the reply, 2 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | BP_A_OL | Open loop |
2 | BP_A_CL | Closed loop |
3 | BP_A_FAULT | Fault |
Confirmed for 2025 to 2026.
Boost pressure A control status supported BP_A_SUPSAE J1979Confirmed
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025 to 2026.
Boost pressure A supported BP_A_ACT_SUPSAE J1979Confirmed
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025 to 2026.
Boost pressure B control status supported BP_B_SUPSAE J1979Confirmed
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025 to 2026.
Boost pressure B supported BP_B_ACT_SUPSAE J1979Confirmed
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 3 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025 to 2026.
Commanded boost pressure A supported BP_A_CMD_SUPSAE J1979Confirmed
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025 to 2026.
Commanded boost pressure B supported BP_B_CMD_SUPSAE J1979Confirmed
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025 to 2026.
EGR Temperature Sensor A (Bank 1, Sensor 1) supported? EGRTA_SUPSAE J1979Confirmed
- Request
01 6B - Service 01
PID 6B - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025 to 2026. Supported for 2019.
EGR Temperature Sensor A (Bank 1, Sensor 1) Wide Range supported? EGRTA_WR_SUPSAE J1979Confirmed
- Request
01 6B - Service 01
PID 6B - Module
7E0 → 7E8 - Every
250 ms
Bit 3 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025 to 2026. Supported for 2019.
EGR Temperature Sensor B (Bank 2, Sensor 1) supported? EGRTB_SUPSAE J1979Confirmed
- Request
01 6B - Service 01
PID 6B - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025 to 2026. Supported for 2019.
EGR Temperature Sensor B (Bank 2, Sensor 1) Wide Range supported? EGRTB_WR_SUPSAE J1979Confirmed
- Request
01 6B - Service 01
PID 6B - Module
7E0 → 7E8 - Every
250 ms
Bit 1 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025 to 2026. Supported for 2019.
EGR Temperature Sensor C (Bank 1, Sensor 2) supported? EGRTC_SUPSAE J1979Confirmed
- Request
01 6B - Service 01
PID 6B - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025 to 2026. Supported for 2019.
EGR Temperature Sensor C (Bank 1, Sensor 2) Wide Range supported? EGRTC_WR_SUPSAE J1979Confirmed
- Request
01 6B - Service 01
PID 6B - Module
7E0 → 7E8 - Every
250 ms
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025 to 2026. Supported for 2019.
EGR Temperature Sensor D (Bank 2, Sensor 2) supported? EGRTD_SUPSAE J1979Confirmed
- Request
01 6B - Service 01
PID 6B - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025 to 2026. Supported for 2019.
EGR Temperature Sensor D (Bank 2, Sensor 2) Wide Range supported? EGRTD_WR_SUPSAE J1979Confirmed
- Request
01 6B - Service 01
PID 6B - Module
7E0 → 7E8 - Every
250 ms
Bit 0 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025 to 2026. Supported for 2019.
IAT Bank 1, Sensor 1 supported IAT_11_SUPSAE J1979Confirmed
- Request
01 68 - Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023, 2025 to 2026.
IAT Bank 1, Sensor 1 supported IAT_21_SUPSAE J1979Confirmed
- Request
01 68 - Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023, 2025 to 2026.
IAT Bank 1, Sensor 2 supported IAT_12_SUPSAE J1979Confirmed
- Request
01 68 - Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023, 2025 to 2026.
IAT Bank 1, Sensor 3 supported IAT_13_SUPSAE J1979Confirmed
- Request
01 68 - Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023, 2025 to 2026.
IAT Bank 2, Sensor 2 supported IAT_22_SUPSAE J1979Confirmed
- Request
01 68 - Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 3 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023, 2025 to 2026.
IAT Bank 2, Sensor 3 supported IAT_23_SUPSAE J1979Confirmed
- Request
01 68 - Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023, 2025 to 2026.
Maximum value for equivalence ratio MAX_EQ_RATSAE J1979Confirmed
- Request
01 4F - Service 01
PID 4F - Module
7E0 → 7E8 - Every
3600 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2025. Supported for 2017, 2020 to 2023.
Maximum value for intake manifold absolute pressure (MAP) MAX_MAPSAE J1979Confirmed
- Request
01 4F - Service 01
PID 4F - Module
7E0 → 7E8 - Every
3600 s
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 kPa
- Unit
- kPa
Confirmed for 2025. Supported for 2017, 2020 to 2023.
Maximum value for oxygen sensor current MAX_O2_CURRSAE J1979Confirmed
- Request
01 4F - Service 01
PID 4F - Module
7E0 → 7E8 - Every
3600 s
Bits 16 to 23 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
Confirmed for 2025. Supported for 2017, 2020 to 2023.
Maximum value for oxygen sensor voltage MAX_O2_VOLTSAE J1979Confirmed
- Request
01 4F - Service 01
PID 4F - Module
7E0 → 7E8 - Every
3600 s
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 V
- Unit
- V
Confirmed for 2025. Supported for 2017, 2020 to 2023.
Engine › OxygenSensors
02S Bank 1, Sensor 1 present O2S11_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2012, 2016, 2018 to 2022, 2024 to 2025. Supported for 2013 to 2015, 2017, 2023, 2026.
02S Bank 1, Sensor 2 present O2S12_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2012, 2016, 2018 to 2022, 2024 to 2025. Supported for 2013 to 2015, 2017, 2023, 2026.
02S Bank 1, Sensor 3 present O2S13_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2012, 2016, 2018 to 2022, 2024 to 2025. Supported for 2013 to 2015, 2017, 2023, 2026.
02S Bank 1, Sensor 4 present O2S14_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2012, 2016, 2018 to 2022, 2024 to 2025. Supported for 2013 to 2015, 2017, 2023, 2026.
02S Bank 2, Sensor 1 present O2S21_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 3 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2012, 2016, 2018 to 2022, 2024 to 2025. Supported for 2013 to 2015, 2017, 2023, 2026.
02S Bank 2, Sensor 2 present O2S22_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2012, 2016, 2018 to 2022, 2024 to 2025. Supported for 2013 to 2015, 2017, 2023, 2026.
02S Bank 2, Sensor 3 present O2S23_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 1 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2012, 2016, 2018 to 2022, 2024 to 2025. Supported for 2013 to 2015, 2017, 2023, 2026.
02S Bank 2, Sensor 4 present O2S24_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 0 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2012, 2016, 2018 to 2022, 2024 to 2025. Supported for 2013 to 2015, 2017, 2023, 2026.
Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed
Pelican can show this parameter as the O2 lambda.
- Request
01 34 - Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32768)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2023, 2025 to 2026. Supported for 2019 to 2022.
Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_VOLTSAE J1979Confirmed
Pelican can show this parameter as the O2 lambda.
- Request
01 24 - Service 01
PID 24 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32768)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2017. Supported for 2019.
O2S Output Voltage Bank 1, Sensor 1 O2S11SAE J1979Confirmed
- Request
01 14 - Service 01
PID 14 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 200)- Range
- 0 to 1.275 V
- Unit
- V
Confirmed for 2016, 2018 to 2022, 2024. Supported for 2012 to 2015, 2017, 2023, 2025.
O2S Output Voltage Bank 1, Sensor 2 O2S12SAE J1979Confirmed
- Request
01 15 - Service 01
PID 15 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 200)- Range
- 0 to 1.275 V
- Unit
- V
Confirmed for 2016, 2018 to 2022, 2024 to 2025. Supported for 2012 to 2015, 2017, 2023, 2026.
O2S Output Voltage Bank 2, Sensor 1 O2S21SAE J1979Confirmed
- Request
01 18 - Service 01
PID 18 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 200)- Range
- 0 to 1.275 V
- Unit
- V
Confirmed for 2018 to 2019. Supported for 2012 to 2017, 2020 to 2024.
O2S Output Voltage Bank 2, Sensor 2 O2S22SAE J1979Confirmed
- Request
01 19 - Service 01
PID 19 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 200)- Range
- 0 to 1.275 V
- Unit
- V
Confirmed for 2018 to 2019, 2025. Supported for 2012 to 2017, 2020 to 2024, 2026.
SHRTFT associated with O2S11 SHRTFT11SAE J1979Confirmed
- Request
01 14 - Service 01
PID 14 - Module
7E0 → 7E8 - Every
1 s
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 128)- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2016, 2018 to 2022, 2024 to 2025. Supported for 2012 to 2015, 2017, 2023, 2026.
SHRTFT associated with O2S21 SHRTFT21SAE J1979Confirmed
- Request
01 18 - Service 01
PID 18 - Module
7E0 → 7E8 - Every
1 s
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 128)- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2018 to 2019. Supported for 2012 to 2017, 2020 to 2024.
SHRTFT associated with O2S22 SHRTFT22SAE J1979Confirmed
- Request
01 19 - Service 01
PID 19 - Module
7E0 → 7E8 - Every
1 s
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 128)- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2018 to 2019, 2025. Supported for 2012 to 2017, 2020 to 2024, 2026.
Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed
- Request
01 34 - Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 256 − 128)- Range
- -128 to 127.996 mA
- Unit
- mA
Confirmed for 2023, 2025 to 2026. Supported for 2019 to 2022.
Wide Range O2S Voltage, O2 Sensor Bank 1, Sensor 1 O2S11_VOLTSAE J1979Confirmed
- Request
01 24 - Service 01
PID 24 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 8196)- Range
- 0 to 7.999 V
- Unit
- V