Drivetrain parameters
The Renault Koleos has 26 drivetrain parameters.
● Confirmed◆ In testing○ Supported× Not supported
2WD mode switch RENAULT_2WD_MODE_SW
- Request
22 30 05 - Service 22
DID 3005 - Module
748 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2025. Not supported for 2026 to 2027.
4WD mode monitor RENAULT_4WD_MODE_MON
- Request
22 30 24 - Service 22
DID 3024 - Module
748 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2025. Not supported for 2026 to 2027.
4WD mode switch RENAULT_4WD_MODE_SW
- Request
22 30 05 - Service 22
DID 3005 - Module
748 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2025. Not supported for 2026 to 2027.
Auto mode switch RENAULT_AUTO_MODE_SW
- Request
22 30 05 - Service 22
DID 3005 - Module
748 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2025. Not supported for 2026 to 2027.
Driving type RENAULT_DRIVE_TYPE
- Request
22 4B 3C - Service 22
DID 4B3C - Module
740 → 760 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2025. Not supported for 2026 to 2027.
Engine torque control RENAULT_ENGINE_TORQUE_CTRL
- Request
22 30 10 - Service 22
DID 3010 - Module
748 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2025. Not supported for 2026 to 2027.
Inverter high voltage RENAULT_INV_HV_V
- Request
22 20 04 - Service 22
DID 2004 - Module
DADF → DF - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.9687 V
- Unit
- V
In testing for 2008 to 2027.
Inverter high voltage current RENAULT_INV_HV_A
- Request
22 70 49 - Service 22
DID 7049 - Module
DADF → DF - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32 − 500)- Range
- -500 to 1547.9687 A
- Unit
- A
In testing for 2008 to 2027.
Inverter state RENAULT_INV_STATE
- Request
22 21 CF - Service 22
DID 21CF - Module
DADA → DA - Every
10 s - Testing
Bits 4 to 7 of the reply, 4 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | OFF | Off |
2 | ON | On |
3 | DISCHARGING | Discharging |
4 | ALTERNATOR | Alternator mode |
5 | SLEEP_READY | Ready to sleep |
In testing for 2008 to 2027.
Inverter temperature RENAULT_INV_T
- Request
22 70 0C - Service 22
DID 700C - Module
DADF → DF - Every
10 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
(val ÷ 512 − 40)- Range
- -40 to 32727.998 °C
- Unit
- °C
In testing for 2008 to 2027.
Inverter temperature, power electronics RENAULT_INV_T_PEB
- Request
22 33 F6 - Service 22
DID 33F6 - Module
7E4 → 7EC - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2008 to 2027.
Motor speed RENAULT_MOTOR_RPM
- Request
22 30 64 - Service 22
DID 3064 - Module
DADA → DA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 2008 to 2027.
Operating mode RENAULT_OP_MODE
- Request
22 30 26 - Service 22
DID 3026 - Module
748 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2025. Not supported for 2026 to 2027.
Operating mode, selected RENAULT_OP_MODE_SEL
- Request
22 30 23 - Service 22
DID 3023 - Module
748 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2025. Not supported for 2026 to 2027.
Rotor current sensor 1 RENAULT_ROTOR_A1
- Request
22 70 03 - Service 22
DID 7003 - Module
DADF → DF - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 A
- Unit
- A
In testing for 2008 to 2027.
Rotor current sensor 2 RENAULT_ROTOR_A2
- Request
22 70 04 - Service 22
DID 7004 - Module
DADF → DF - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 A
- Unit
- A
In testing for 2008 to 2027.
Rotor reference resistance RENAULT_ROTOR_R
- Request
22 70 50 - Service 22
DID 7050 - Module
DADF → DF - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 512)- Range
- 0 to 127.998 Ω
- Unit
- Ω
In testing for 2008 to 2027.
Rotor temperature, estimated RENAULT_ROTOR_T
- Request
22 70 88 - Service 22
DID 7088 - Module
DADF → DF - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 128 − 40)- Range
- -40 to 471.9921 °C
- Unit
- °C
In testing for 2008 to 2027.
Rotor temperature, raw RENAULT_ROTOR_T_RAW
- Request
22 70 38 - Service 22
DID 7038 - Module
DADF → DF - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 128 − 40)- Range
- -40 to 471.9921 °C
- Unit
- °C
In testing for 2008 to 2027.
Stator current, phase U RENAULT_STATOR_A_U
- Request
22 70 07 - Service 22
DID 7007 - Module
DADF → DF - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32 − 500)- Range
- -500 to 1547.9687 A
- Unit
- A
In testing for 2008 to 2027.
Stator current, phase V RENAULT_STATOR_A_V
- Request
22 70 08 - Service 22
DID 7008 - Module
DADF → DF - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32 − 500)- Range
- -500 to 1547.9687 A
- Unit
- A
In testing for 2008 to 2027.
Stator current, phase W RENAULT_STATOR_A_W
- Request
22 70 09 - Service 22
DID 7009 - Module
DADF → DF - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32 − 500)- Range
- -500 to 1547.9687 A
- Unit
- A
In testing for 2008 to 2027.
Stator temperature 1 RENAULT_STATOR_T1
- Request
22 70 0F - Service 22
DID 700F - Module
DADF → DF - Every
10 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
(val ÷ 512 − 40)- Range
- -40 to 32727.998 °C
- Unit
- °C
In testing for 2008 to 2027.
Stator temperature 2 RENAULT_STATOR_T2
- Request
22 70 10 - Service 22
DID 7010 - Module
DADF → DF - Every
10 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
(val ÷ 512 − 40)- Range
- -40 to 32727.998 °C
- Unit
- °C
In testing for 2008 to 2027.
Traction control RENAULT_TRACTION_CTRL
- Request
22 30 10 - Service 22
DID 3010 - Module
748 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2025. Not supported for 2026 to 2027.
Trajectory control RENAULT_TRAJECTORY_CTRL
- Request
22 30 10 - Service 22
DID 3010 - Module
748 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2025. Not supported for 2026 to 2027.