Renault Zoe

Climate parameters

The Renault Zoe has 16 climate parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

A/C compressor discharge temperature ZOE_COMP_DIS_T

  • Request22 44 0C
  • Service 22DID 440C
  • Module744 → 764
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2 − 30)
Range
-30 to 32737.5 °C
Unit
°C

In testing for 2012 to 2024.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

A/C compressor discharge temperature ZOE_COMP_DIS_T

  • Request22 44 0C
  • Service 22DID 440C
  • Module744 → 764
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2 − 30)
Range
-30 to 32737.5 °C
Unit
°C

In testing for 2012 to 2024.

A/C compressor mode ZOE_COMP_MODE

  • Request22 44 02
  • Service 22DID 4402
  • Module744 → 764
  • Every5 s
  • Testing

Bits 4 to 7 of the reply, 4 bits.

Unit
Named states
States
Raw valueStateMeaning
1ACA/C
2DEICEDe-ice
4HEAT_PUMPHeat pump
6DEMISTDemisting
7IDLEIdle

In testing for 2012 to 2024.

A/C compressor power ZOE_COMP_PWR

  • Request22 44 36
  • Service 22DID 4436
  • Module744 → 764
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383.75 W
Unit
W

In testing for 2012 to 2024.

A/C compressor pressure ZOE_COMP_P

  • Request22 43 69
  • Service 22DID 4369
  • Module744 → 764
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553.5 bar
Unit
bar

In testing for 2012 to 2024.

A/C compressor speed ZOE_COMP_RPM

  • Request22 43 D8
  • Service 22DID 43D8
  • Module744 → 764
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2012 to 2024.

A/C compressor speed request ZOE_COMP_RPM_REQ

  • Request22 44 04
  • Service 22DID 4404
  • Module744 → 764
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2012 to 2024.

A/C compressor suction temperature ZOE_COMP_SUC_T

  • Request22 44 0D
  • Service 22DID 440D
  • Module744 → 764
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2 − 30)
Range
-30 to 32737.5 °C
Unit
°C

In testing for 2012 to 2024.

Ambient air temperature AATSAE J1979Confirmed

  • Request01 46
  • Service 01PID 46
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2020 to 2021. Supported for 2022.

Ambient air temperature ZOE_AAT

  • Request22 22 18
  • Service 22DID 2218
  • ModuleDADA → DA
  • Every20 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273)
Range
-273 to 6280.5 °C
Unit
°C

In testing for 2012 to 2024.

Cabin temperature ZOE_CABIN_T

  • Request22 40 09
  • Service 22DID 4009
  • Module744 → 764
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 40)
Range
-3316.8 to 3236.7 °C
Unit
°C

In testing for 2012 to 2024.

Electric heater request ZOE_PTC_REQ

  • Request22 43 41
  • Service 22DID 4341
  • Module744 → 764
  • Every5 s
  • Testing

Bits 4 to 7 of the reply, 4 bits.

Formula
val
Range
0 to 15
Unit
Number

In testing for 2012 to 2024.

Evaporator temperature ZOE_EVAP_T

  • Request22 40 0A
  • Service 22DID 400A
  • Module744 → 764
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2012 to 2024.

Evaporator temperature set point ZOE_EVAP_T_SET

  • Request22 43 68
  • Service 22DID 4368
  • Module744 → 764
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2012 to 2024.

Heating condenser temperature ZOE_COND_T

  • Request22 44 29
  • Service 22DID 4429
  • Module744 → 764
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 256 − 40)
Range
-40 to 215.996 °C
Unit
°C

In testing for 2012 to 2024.

Heating condenser temperature set point ZOE_COND_T_SET

  • Request22 43 A5
  • Service 22DID 43A5
  • Module744 → 764
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 512 − 40)
Range
-40 to 87.998 °C
Unit
°C

In testing for 2012 to 2024.

Heating temperature ZOE_HEAT_T

  • Request22 43 A4
  • Service 22DID 43A4
  • Module744 → 764
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 256 − 40)
Range
-40 to 215.996 °C
Unit
°C

In testing for 2012 to 2024.