Battery parameters
The Subaru Solterra has 35 battery parameters.
● Confirmed◆ In testing○ Supported× Not supported
12V aux battery temperature SUBARU_12V_AUX_BAT_T
- Request
22 20 E2 - Service 22
DID 20E2 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- -40 to 87.5 °C
- Unit
- °C
Not supported for 2023 to 2026.
12V aux battery voltage SUBARU_12V_AUX_BAT_VOLTAGE
Pelican can show this parameter as the starter battery voltage.
- Request
22 10 37 - Service 22
DID 1037 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 25.5 ÷ 255)- Range
- 0 to 25.5 V
- Unit
- V
Not supported for 2023 to 2026.
12V battery current SUBARU_12V_C
- Request
22 11 35 - Service 22
DID 1135 - Module
7A2 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 128)- Range
- -128 to 127 mA
- Unit
- mA
Not supported for 2023 to 2026.
12V battery temperature SUBARU_12V_T
- Request
22 11 36 - Service 22
DID 1136 - Module
7A2 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Not supported for 2023 to 2026.
12V engine restart battery current SUBARU_12V_CURRENT
- Request
22 20 12 - Service 22
DID 2012 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 2000)- Range
- -2000 to 4553.5 A
- Unit
- A
Not supported for 2023 to 2026.
12V engine restart battery soc SUBARU_12V_ENGINE_RESTART_BAT_SOC
- Request
22 10 77 - Service 22
DID 1077 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 127.5 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Not supported for 2023 to 2026.
12V engine restart battery soc control SUBARU_12V_SOC_CONTROL
- Request
22 20 14 - Service 22
DID 2014 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 127.5 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Not supported for 2023 to 2026.
12V engine restart battery temperature SUBARU_12V_ENGINE_RESTART_BAT_T
- Request
22 10 79 - Service 22
DID 1079 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Not supported for 2023 to 2026.
12V engine restart battery voltage SUBARU_12V_ENGINE_RESTART_BAT_VOLTAGE
- Request
22 10 39 - Service 22
DID 1039 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 25.5 ÷ 255)- Range
- 0 to 25.5 V
- Unit
- V
Not supported for 2023 to 2026.
Battery charge/discharge current SUBARU_BAT_CHARGE_DISCHARGE_CURRENT
- Request
22 13 22 - Service 22
DID 1322 - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val × 10 ÷ 10000 − 2000)- Range
- -2000 to 4292967 A
- Unit
- A
Not supported for 2023 to 2026.
Battery terminal voltage SUBARU_BAT_TERMINAL_VOLTAGE
Pelican can show this parameter as the starter battery voltage.
- Request
22 13 21 - Service 22
DID 1321 - Module
7A2 → 7AA - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
Not supported for 2023 to 2026.
Estimated battery temperature SUBARU_ESTIMATED_BAT_T
- Request
22 13 23 - Service 22
DID 1323 - Module
7A2 → 7AA - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2 − 40)- Range
- -40 to 32727.5 °C
- Unit
- °C
Not supported for 2023 to 2026.
High voltage battery cell temperature estimated SUBARU_HVBAT_CELL_T
- Request
22 11 43 - Service 22
DID 1143 - Module
7E3 → 7EB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 100)- Range
- -100 to 6453.5 °C
- Unit
- °C
In testing for 2025 to 2026. Not supported for 2023 to 2024.
High voltage battery charge power SUBARU_HVBAT_CHG_POWER
- Request
22 20 26 - Service 22
DID 2026 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 kW
- Unit
- kW
In testing for 2025 to 2026. Not supported for 2023 to 2024.
High voltage battery cooling fan duty output SUBARU_HVBAT_COOLING_FAN_DUTY
- Request
22 10 84 - Service 22
DID 1084 - Module
7E6 → 7EE - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2025 to 2026. Not supported for 2023 to 2024.
High voltage battery cooling fan duty, target SUBARU_HVBAT_COOLING_FAN_DUTY_TGT
- Request
22 10 7A - Service 22
DID 107A - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2025 to 2026. Not supported for 2023 to 2024.
High voltage battery cooling fan duty, target SUBARU_HVBAT_COOLING_FAN_DUTY_TGT_7E7
- Request
22 20 0C - Service 22
DID 200C - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 2025 to 2026. Not supported for 2023 to 2024.
High voltage battery cooling fan duty, target SUBARU_HVBAT_COOLING_FAN_TGT
- Request
22 10 82 - Service 22
DID 1082 - Module
7E6 → 7EE - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2025 to 2026. Not supported for 2023 to 2024.
High voltage battery cooling fan speed SUBARU_HVBAT_COOLING_FAN
- Request
22 10 81 - Service 22
DID 1081 - Module
7E6 → 7EE - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 2025 to 2026. Not supported for 2023 to 2024.
High voltage battery current SUBARU_HVBAT_CURRENT
- Request
22 20 0A - Service 22
DID 200A - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 200)- Range
- -200 to 6353.5 A
- Unit
- A
In testing for 2025 to 2026. Not supported for 2023 to 2024.
High voltage battery discharge power SUBARU_HVBAT_DCHG_POWER
- Request
22 20 25 - Service 22
DID 2025 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 kW
- Unit
- kW
In testing for 2025 to 2026. Not supported for 2023 to 2024.
High voltage battery intake air temperature SUBARU_HVBAT_IAT
- Request
22 10 2D - Service 22
DID 102D - Module
7E3 → 7EB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2 − 100)- Range
- -100 to 32667.5 °C
- Unit
- °C
In testing for 2025 to 2026. Not supported for 2023 to 2024.
High voltage battery intake air temperature SUBARU_HVBAT_IAT_7E7
- Request
22 20 24 - Service 22
DID 2024 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- -40 to 87.5 %
- Unit
- %
In testing for 2025 to 2026. Not supported for 2023 to 2024.
High voltage battery state of charge SUBARU_HVBAT_ST_CHG
- Request
22 10 21 - Service 22
DID 1021 - Module
7E3 → 7EB - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 100 %
- Unit
- %
In testing for 2025 to 2026. Not supported for 2023 to 2024.
High voltage battery state of charge SUBARU_HVBAT_ST_CHG_7E7
- Request
22 10 33 - Service 22
DID 1033 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 100 %
- Unit
- %
In testing for 2025 to 2026. Not supported for 2023 to 2024.
High voltage battery state of health SUBARU_HVBAT_ST_HEALTH
- Request
22 20 21 - Service 22
DID 2021 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 100 %
- Unit
- %
In testing for 2025 to 2026. Not supported for 2023 to 2024.
High voltage battery temperature 1 SUBARU_HVBAT_T_1
- Request
22 10 2A - Service 22
DID 102A - Module
7E3 → 7EB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2 − 100)- Range
- -100 to 32667.5 °C
- Unit
- °C
In testing for 2025 to 2026. Not supported for 2023 to 2024.
High voltage battery temperature 2 SUBARU_HVBAT_T_2
- Request
22 10 2B - Service 22
DID 102B - Module
7E3 → 7EB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2 − 100)- Range
- -100 to 32667.5 °C
- Unit
- °C
In testing for 2025 to 2026. Not supported for 2023 to 2024.
High voltage battery temperature 3 SUBARU_HVBAT_T_3
- Request
22 10 2C - Service 22
DID 102C - Module
7E3 → 7EB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2 − 100)- Range
- -100 to 32667.5 °C
- Unit
- °C
In testing for 2025 to 2026. Not supported for 2023 to 2024.
High voltage battery temperature max SUBARU_HVBAT_T_MAX
- Request
22 20 22 - Service 22
DID 2022 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- -40 to 87.5 %
- Unit
- %
In testing for 2025 to 2026. Not supported for 2023 to 2024.
High voltage battery temperature min SUBARU_HVBAT_T_MIN
- Request
22 20 23 - Service 22
DID 2023 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- -40 to 87.5 %
- Unit
- %
In testing for 2025 to 2026. Not supported for 2023 to 2024.
High voltage battery total voltage SUBARU_HVBAT_TOT_V
- Request
22 20 09 - Service 22
DID 2009 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 2025 to 2026. Not supported for 2023 to 2024.
Mass airflow sensor voltage SUBARU_MAF_VOLTAGEConfirmed
- Request
22 10 A1 - Service 22
DID 10A1 - Module
7A2 → 7AA - Every
1 s - Testing
Example reply from a 2024 Subaru Solterra.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → (0 ÷ 50) = 0 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2024. Not supported for 2023, 2025 to 2026.
Remaining battery capacity SUBARU_REMAINING_BAT_CAPACITY
Pelican can show this parameter as the state of charge.
- Request
22 13 24 - Service 22
DID 1324 - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 100 %
- Unit
- %
Not supported for 2023 to 2026.
Throttle motor voltage SUBARU_THROTTLE_MOTOR_V
- Request
22 12 75 - Service 22
DID 1275 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 2 ÷ 25)- Range
- 0 to 20.4 V
- Unit
- V
In testing for 2024 to 2026. Not supported for 2023.