Subaru Solterra

Connectable parameters

The Subaru Solterra has 24 Connectables, parameters that Pelican can monitor automatically.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Remaining battery capacity SUBARU_REMAINING_BAT_CAPACITY

Pelican can show this parameter as the state of charge.

  • Request22 13 24
  • Service 22DID 1324
  • Module7A2 → 7AA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 100 %
Unit
%

Not supported for 2023 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

State of charge

Remaining battery capacity SUBARU_REMAINING_BAT_CAPACITY

Pelican can show this parameter as the state of charge.

  • Request22 13 24
  • Service 22DID 1324
  • Module7A2 → 7AA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 100 %
Unit
%

Not supported for 2023 to 2026.

Fuel tank level

Fuel level SUBARU_FLI

Pelican can show this parameter as the fuel tank level.

  • Request22 00 2F
  • Service 22DID 002F
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Not supported for 2023 to 2026.

Fuel level, volume SUBARU_FLI_VOL

Pelican can show this parameter as the fuel tank level.

  • Request21 29
  • Service 21PID 29
  • Module7C0 → 7C8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127.5 L
Unit
L

In testing for 2024 to 2026. Not supported for 2023.

Odometer

Odometer SUBARU_ODO_7A2_10A5

Pelican can show this parameter as the odometer.

  • Request22 10 A5
  • Service 22DID 10A5
  • Module7A2 → 7AA
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 2)
Range
0 to 131070 km
Unit
km

In testing for 2024. Not supported for 2023, 2025 to 2026.

Odometer SUBARU_ODO_7A2_10E5

Pelican can show this parameter as the odometer.

  • Request22 10 E5
  • Service 22DID 10E5
  • Module7A2 → 7AA
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 2)
Range
0 to 131070 km
Unit
km

In testing for 2024. Not supported for 2023, 2025 to 2026.

Odometer SUBARU_ODO

Pelican can show this parameter as the odometer.

  • Request22 10 E5
  • Service 22DID 10E5
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 2)
Range
0 to 131070 km
Unit
km

Not supported for 2023 to 2026.

Front left tire pressure

Front left tire pressure SUBARU_TP_FL_750

Pelican can show this parameter as the front left tire pressure.

  • Request21 30
  • Service 21PID 30
  • Module750
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 58 − 0.5)
Range
0 to 3.89 bar
Unit
bar

In testing for 2024 to 2026. Not supported for 2023.

Front left tire pressure SUBARU_TP_FL

Pelican can show this parameter as the front left tire pressure.

  • Request22 10 22
  • Service 22DID 1022
  • Module753 → 75B
  • Every15 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
(val ÷ 5)
Range
0 to 51 psi
Unit
psi

Not supported for 2023 to 2026.

Front left tire pressure, variant 2 SUBARU_TP_2_FL

Pelican can show this parameter as the front left tire pressure.

  • Request21 15
  • Service 21PID 15
  • Module750
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 58 − 0.5)
Range
0 to 3.89 bar
Unit
bar

In testing for 2024 to 2026. Not supported for 2023.

Front right tire pressure

Front right tire pressure SUBARU_TP_FR_750

Pelican can show this parameter as the front right tire pressure.

  • Request21 30
  • Service 21PID 30
  • Module750
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val ÷ 58 − 0.5)
Range
0 to 3.89 bar
Unit
bar

In testing for 2024 to 2026. Not supported for 2023.

Front right tire pressure SUBARU_TP_FR

Pelican can show this parameter as the front right tire pressure.

  • Request22 10 22
  • Service 22DID 1022
  • Module753 → 75B
  • Every15 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val ÷ 5)
Range
0 to 51 psi
Unit
psi

Not supported for 2023 to 2026.

Front right tire pressure, variant 2 SUBARU_TP_2_FR

Pelican can show this parameter as the front right tire pressure.

  • Request21 15
  • Service 21PID 15
  • Module750
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val ÷ 58 − 0.5)
Range
0 to 3.89 bar
Unit
bar

In testing for 2024 to 2026. Not supported for 2023.

Rear left tire pressure

Rear left tire pressure SUBARU_TP_RL_750

Pelican can show this parameter as the rear left tire pressure.

  • Request21 30
  • Service 21PID 30
  • Module750
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val ÷ 58 − 0.5)
Range
0 to 3.89 bar
Unit
bar

In testing for 2024 to 2026. Not supported for 2023.

Rear left tire pressure SUBARU_TP_RL

Pelican can show this parameter as the rear left tire pressure.

  • Request22 10 22
  • Service 22DID 1022
  • Module753 → 75B
  • Every15 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 5)
Range
0 to 51 psi
Unit
psi

Not supported for 2023 to 2026.

Rear left tire pressure, variant 2 SUBARU_TP_2_RL

Pelican can show this parameter as the rear left tire pressure.

  • Request21 15
  • Service 21PID 15
  • Module750
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val ÷ 58 − 0.5)
Range
0 to 3.89 bar
Unit
bar

In testing for 2024 to 2026. Not supported for 2023.

Rear right tire pressure

Rear right tire pressure SUBARU_TP_RR_750

Pelican can show this parameter as the rear right tire pressure.

  • Request21 30
  • Service 21PID 30
  • Module750
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
(val ÷ 58 − 0.5)
Range
0 to 3.89 bar
Unit
bar

In testing for 2024 to 2026. Not supported for 2023.

Rear right tire pressure SUBARU_TP_RR

Pelican can show this parameter as the rear right tire pressure.

  • Request22 10 22
  • Service 22DID 1022
  • Module753 → 75B
  • Every15 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val ÷ 5)
Range
0 to 51 psi
Unit
psi

Not supported for 2023 to 2026.

Rear right tire pressure, variant 2 SUBARU_TP_2_RR

Pelican can show this parameter as the rear right tire pressure.

  • Request21 15
  • Service 21PID 15
  • Module750
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
(val ÷ 58 − 0.5)
Range
0 to 3.89 bar
Unit
bar

In testing for 2024 to 2026. Not supported for 2023.

Engine oil temperature

Engine oil temperature SUBARU_EOT

Pelican can show this parameter as the engine oil temperature.

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 224 to 231 of the reply, 8 bits.

Formula
(val − 40)
Range
0 to 215 °C
Unit
°C

In testing for 2024 to 2026. Not supported for 2023.

Engine oil temperature SUBARU_EOT_V2

Pelican can show this parameter as the engine oil temperature.

  • Request22 10 E7
  • Service 22DID 10E7
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Not supported for 2023 to 2026.

Starter battery voltage

12V aux battery voltage SUBARU_12V_AUX_BAT_VOLTAGE

Pelican can show this parameter as the starter battery voltage.

  • Request22 10 37
  • Service 22DID 1037
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 25.5 ÷ 255)
Range
0 to 25.5 V
Unit
V

Not supported for 2023 to 2026.

Battery terminal voltage SUBARU_BAT_TERMINAL_VOLTAGE

Pelican can show this parameter as the starter battery voltage.

  • Request22 13 21
  • Service 22DID 1321
  • Module7A2 → 7AA
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

Not supported for 2023 to 2026.

Transmission fluid temperature

CVT fluid temperature SUBARU_CVT_T_V2

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 10 17
  • Service 22DID 1017
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2024 to 2026. Not supported for 2023.

Transmission fluid temperature SUBARU_TCM_ATF_T

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 10 D2
  • Service 22DID 10D2
  • Module7A3 → 7AB
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

Not supported for 2023 to 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.