Suzuki Jimny

Climate parameters

The Suzuki Jimny has 30 climate parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Adjusted ambient temperature SUZUKI_ADJUSTED_AMBIENT_T

  • Request21 3D
  • Service 21PID 3D
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 81.6 ÷ 255 − 30.8)
Range
-30.8 to 50.8 °C
Unit
°C

In testing for 1988 to 2022, 2024, 2026. Not supported for 2023, 2025.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Adjusted ambient temperature SUZUKI_ADJUSTED_AMBIENT_T

  • Request21 3D
  • Service 21PID 3D
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 81.6 ÷ 255 − 30.8)
Range
-30.8 to 50.8 °C
Unit
°C

In testing for 1988 to 2022, 2024, 2026. Not supported for 2023, 2025.

Air conditioner feedback SUZUKI_AC_FB

  • Request21 51
  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 216 to 231 of the reply, 16 bits.

Formula
(val × 10 ÷ 8192 − 40)
Range
-40 to 39.99
Unit
Number

In testing for 1988 to 2024, 2026. Not supported for 2025.

Air conditioning inverter gate SUZUKI_AC_GATE

  • Request21 C4
  • Service 21PID C4
  • Module7E2
  • Every250 ms
  • Testing

Bit 67 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1988 to 2026.

Air conditioning power consumption SUZUKI_AC_PWR

  • Request21 C4
  • Service 21PID C4
  • Module7E2
  • Every250 ms
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
(val ÷ 51)
Range
0 to 5 kW
Unit
kW

In testing for 1988 to 2026.

Air conditioning requested SUZUKI_AC_REQ

  • Request21 C4
  • Service 21PID C4
  • Module7E2
  • Every250 ms
  • Testing

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1988 to 2026.

Air inlet damper actual pulse SUZUKI_AIR_INLET_DAMPER_ACTUAL_PULSE

  • Request21 44
  • Service 21PID 44
  • Module7C4
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1988 to 2022, 2024, 2026. Not supported for 2023, 2025.

Air inlet damper target pulse SUZUKI_AIR_INLET_DAMPER_TARGET_PULSE

  • Request21 44
  • Service 21PID 44
  • Module7C4
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1988 to 2022, 2024, 2026. Not supported for 2023, 2025.

Air outlet servo actual pulse, driver SUZUKI_AIR_OUTLET_SERVO_ACTU_PULSE_D

  • Request21 43
  • Service 21PID 43
  • Module7C4
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1988 to 2022, 2024, 2026. Not supported for 2023, 2025.

Air outlet servo pulse, driver SUZUKI_AIR_OUTLET_SERVO_PULSE_D

  • Request21 43
  • Service 21PID 43
  • Module7C4
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1988 to 2022, 2024, 2026. Not supported for 2023, 2025.

Ambient air temperature SUZUKI_AAT_7C4

  • Request21 22
  • Service 21PID 22
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 89.25 ÷ 255 − 23.3)
Range
-23.3 to 65.95 °C
Unit
°C

In testing for 1988 to 2022, 2024, 2026. Not supported for 2023, 2025.

Ambient temperature SUZUKI_AMBIENT_T

  • Request22 1F 46
  • Service 22DID 1F46
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1988 to 2008, 2010 to 2022, 2024, 2026. Not supported for 2009, 2023, 2025.

Ambient temperature for A/C SUZUKI_AC_AMB_T

  • Request21 51
  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1988 to 2024, 2026. Not supported for 2025.

Ambient temperature, climate SUZUKI_AAT_7C4_V2

  • Request22 10 02
  • Service 22DID 1002
  • Module7C4 → 7CC
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327.68 to 327.67 °C
Unit
°C

In testing for 1988 to 2026.

Blower level SUZUKI_BLOWER

  • Request22 28 01
  • Service 22DID 2801
  • Module7C4 → 7CC
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 7
Unit
Number

In testing for 1988 to 2026.

Blower motor speed level SUZUKI_BLOWER_MOTOR_SPEED_LEVEL

  • Request21 3C
  • Service 21PID 3C
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1988 to 2022, 2024, 2026. Not supported for 2023, 2025.

Cabin mode active while parked SUZUKI_MY_ROOM

  • Request22 16 92
  • Service 22DID 1692
  • Module745 → 74D
  • Every10 s
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 1988 to 2026.

Cabin temperature SUZUKI_CABIN_T

  • Request21 21
  • Service 21PID 21
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 63.75 ÷ 255 − 6.5)
Range
-6.5 to 57.25 °C
Unit
°C

In testing for 1988 to 2022, 2024, 2026. Not supported for 2023, 2025.

Cabin temperature SUZUKI_CABIN_T_V2

  • Request22 10 01
  • Service 22DID 1001
  • Module7C4 → 7CC
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327.68 to 327.67 °C
Unit
°C

In testing for 1988 to 2026.

Climate control engine run requested SUZUKI_HVAC_REQ

  • Request21 C4
  • Service 21PID C4
  • Module7E2
  • Every250 ms
  • Testing

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1988 to 2026.

Climate power SUZUKI_HVAC_P

  • Request22 10 6E
  • Service 22DID 106E
  • Module7D2 → 7DA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 20)
Range
0 to 12.75 kW
Unit
kW

In testing for 1988 to 2026.

Climate power, charging control SUZUKI_HVAC_P_745

  • Request22 10 6E
  • Service 22DID 106E
  • Module745 → 74D
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 20)
Range
0 to 12.75 kW
Unit
kW

In testing for 1988 to 2026.

Climate set point code SUZUKI_HVAC_SET_RAW

  • Request22 10 36
  • Service 22DID 1036
  • Module7C4 → 7CC
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1988 to 2026.

Communication with air conditioner SUZUKI_COMM_WITH_AIR_CONDITIONER

  • Request21 24
  • Service 21PID 24
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1988 to 2024, 2026. Not supported for 2025.

Communication with HV SUZUKI_COMMUNICATION_WITH_HV

  • Request21 24
  • Service 21PID 24
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1988 to 2024, 2026. Not supported for 2025.

Communication with valvematic SUZUKI_COMM_WITH_VALVEMATIC_COMM

  • Request21 24
  • Service 21PID 24
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1988 to 2024, 2026. Not supported for 2025.

Electric heater power count SUZUKI_HEATER_RAW

  • Request22 10 86
  • Service 22DID 1086
  • Module7C4 → 7CC
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1988 to 2026.

Evaporator fin thermistor SUZUKI_EVAP_FIN_THERMISTOR

  • Request21 4B
  • Service 21PID 4B
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 89.25 ÷ 255 − 29.7)
Range
-29.7 to 59.55 °C
Unit
°C

In testing for 1988 to 2022, 2024, 2026. Not supported for 2023, 2025.

Evaporator target temperature SUZUKI_EVAP_TARGET_T

  • Request21 4C
  • Service 21PID 4C
  • Module7C4
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67
Unit
Number

In testing for 1988 to 2022, 2024, 2026. Not supported for 2023, 2025.

Set temperature, driver side SUZUKI_T_DRIVER

  • Request21 29
  • Service 21PID 29
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 1988 to 2022, 2024, 2026. Not supported for 2023, 2025.

Solar sensor, driver side SUZUKI_SOLAR_DRIVER

  • Request21 24
  • Service 21PID 24
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1988 to 2022, 2024, 2026. Not supported for 2023, 2025.