DTC parameters
The Suzuki Jimny has 23 DTC parameters.
● Confirmed◆ In testing○ Supported× Not supported
2nd air monitor_avail SUZUKI_2ND_AIR_MONITOR_AVAIL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 20 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2024, 2026. Not supported for 2025.
2nd air monitor_incmpl SUZUKI_2ND_AIR_MONITOR_INCMPL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 28 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2024, 2026. Not supported for 2025.
A/C monitor_avail SUZUKI_A_C_MONITOR_AVAIL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 19 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2024, 2026. Not supported for 2025.
A/C monitor_incmpl SUZUKI_A_C_MONITOR_INCMPL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 27 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2024, 2026. Not supported for 2025.
Catalyst monitor_avail SUZUKI_CATALYST_MONITOR_AVAIL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 23 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2024, 2026. Not supported for 2025.
Catalyst monitor_incmpl SUZUKI_CATALYST_MONITOR_INCMPL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 31 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2024, 2026. Not supported for 2025.
Complete parts monitor_avail SUZUKI_COMPLETE_PARTS_MONITOR_AVAIL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 13 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2024, 2026. Not supported for 2025.
EGR/VVT monitor_avail SUZUKI_EGR_VVT_MONITOR_AVAIL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 16 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2024, 2026. Not supported for 2025.
EGR/VVT monitor_incmpl SUZUKI_EGR_VVT_MONITOR_INCMPL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 24 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2024, 2026. Not supported for 2025.
EVAP monitor_avail SUZUKI_EVAP_MONITOR_AVAIL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 21 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2024, 2026. Not supported for 2025.
EVAP monitor_icmpl SUZUKI_EVAP_MONITOR_ICMPL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 29 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2024, 2026. Not supported for 2025.
Fuel system monitor_avail SUZUKI_FUEL_SYSTEM_MONITOR_AVAIL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 14 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2024, 2026. Not supported for 2025.
Heated catalyst monitor_avail SUZUKI_HEATED_CATALYST_MONITOR_AVAIL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 22 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2024, 2026. Not supported for 2025.
Heated catalyst monitor_incmpl SUZUKI_HEATED_CATALYST_MONITOR_INCMPL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 30 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2024, 2026. Not supported for 2025.
MIL SUZUKI_MIL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2024, 2026. Not supported for 2025.
MIL ON run distance SUZUKI_MILON_RUN_DISTANCE
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 km
- Unit
- km
In testing for 1988 to 2024, 2026. Not supported for 2025.
Misfire monitor_avail SUZUKI_MISFIRE_MONITOR_AVAIL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 15 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2024, 2026. Not supported for 2025.
Number of emission DTC SUZUKI_NUMBER_OF_EMISSION_DTC
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 1 to 7 of the reply, 7 bits.
- Formula
val- Range
- 0 to 127
- Unit
- Number
In testing for 1988 to 2024, 2026. Not supported for 2025.
O2S heater monitor_avail SUZUKI_O2S_A_FS_HEATER_MONITOR_AVAIL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 17 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2024, 2026. Not supported for 2025.
O2S heater monitor_incmpl SUZUKI_O2S_A_FS_HEATER_MONITOR_INCMPL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 25 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2024, 2026. Not supported for 2025.
O2S monitor_avail SUZUKI_O2S_A_FS_MONITOR_AVAIL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 18 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2024, 2026. Not supported for 2025.
O2S monitor_incmpl SUZUKI_O2S_A_FS_MONITOR_INCMPL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 26 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2024, 2026. Not supported for 2025.
Running time from MIL ON SUZUKI_RUNNING_TIME_FROM_MIL_ON
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 min
- Unit
- min
In testing for 1988 to 2024, 2026. Not supported for 2025.