Battery parameters
The Suzuki Swift has 222 battery parameters.
● Confirmed◆ In testing○ Supported× Not supported
12V battery current SUZUKI_12V_C
- Request
22 15 F7 - Service 22
DID 15F7 - Module
7D2 → 7DA - Every
500 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 38.147 ÷ 10000 − 125)- Range
- -125 to 124 A
- Unit
- A
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
12V battery temperature SUZUKI_12V_T
- Request
22 15 F8 - Service 22
DID 15F8 - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
12V battery voltage SUZUKI_12V_V_V2
Pelican can show this parameter as the starter battery voltage.
- Request
22 15 EE - Service 22
DID 15EE - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 0.31448 + 0.0125)- Range
- 0 to 80.2 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
AC charging operation status SUZUKI_AC_OP
- Request
22 16 84 - Service 22
DID 1684 - Module
745 → 74D - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | STOP | Stopped |
1 | STARTUP | Starting up |
2 | RUNNING | Running |
3 | FINISHING | Finishing |
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
AC current limit SUZUKI_AC_A_LIMIT
- Request
22 16 19 - Service 22
DID 1619 - Module
745 → 74D - Every
5 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 A
- Unit
- A
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
AC target power SUZUKI_AC_P_TGT
- Request
22 16 19 - Service 22
DID 1619 - Module
745 → 74D - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 kW
- Unit
- kW
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
AC usable power SUZUKI_AC_P_USABLE
- Request
22 16 65 - Service 22
DID 1665 - Module
745 → 74D - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 100)- Range
- 0 to 2.55 kW
- Unit
- kW
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
Air fuel sensor voltage, bank 1 sensor 1 SUZUKI_AFS_VOLTAGE_B1S1
- Request
21 04 - Service 21
PID 04 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val × 7.99 ÷ 65535)- Range
- 0 to 7.99 V
- Unit
- V
In testing for 1988 to 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2009, 2019 to 2020, 2024.
Auxiliary battery voltage SUZUKI_AUX_V
Pelican can show this parameter as the starter battery voltage.
- Request
21 CF - Service 21
PID CF - Module
7E3 - Every
5 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val ÷ 5 − 25.6)- Range
- -25.6 to 25.4 V
- Unit
- V
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
Battery charging power SUZUKI_CHG_P
- Request
22 10 D4 - Service 22
DID 10D4 - Module
745 → 74D - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 kW
- Unit
- kW
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
Battery voltage SUZUKI_12V_V
Pelican can show this parameter as the starter battery voltage.
- Request
22 10 02 - Service 22
DID 1002 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 12.207 ÷ 10000)- Range
- 0 to 79 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
Battery voltage SUZUKI_BAT_V
- Request
21 13 - Service 21
PID 13 - Module
7C0 → 7C8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
Battery voltage SUZUKI_BATTERY_VOLTAGE
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1988 to 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2009, 2019 to 2020, 2024.
Boost converter carrier frequency SUZUKI_CONV_CARRIER
- Request
21 C4 - Service 21
PID C4 - Module
7E2 - Every
250 ms - Testing
Bit 71 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
Boost converter gate SUZUKI_CONV_GATE
- Request
21 C4 - Service 21
PID C4 - Module
7E2 - Every
250 ms - Testing
Bit 66 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
Boost converter input voltage SUZUKI_VL
- Request
21 C4 - Service 21
PID C4 - Module
7E2 - Every
250 ms - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 2)- Range
- 0 to 510 V
- Unit
- V
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
Boost converter output voltage SUZUKI_VH
- Request
21 C4 - Service 21
PID C4 - Module
7E2 - Every
250 ms - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 2)- Range
- 0 to 510 V
- Unit
- V
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
Boost converter pressure ratio SUZUKI_BOOST_RATIO
- Request
21 C4 - Service 21
PID C4 - Module
7E2 - Every
250 ms - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val × 0.392)- Range
- 0 to 99.96 %
- Unit
- %
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
Boost converter temperature SUZUKI_CONV_T
- Request
21 C4 - Service 21
PID C4 - Module
7E2 - Every
250 ms - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
Charge contactor current SUZUKI_SCC_SOLENOID_CURRENT
- Request
21 A3 - Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
Charge stop request code SUZUKI_CHG_STOP_REQ
- Request
22 16 67 - Service 22
DID 1667 - Module
745 → 74D - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
Charger input power SUZUKI_CHG_IN_P
- Request
22 16 1D - Service 22
DID 161D - Module
745 → 74D - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 200)- Range
- 0 to 327.675 kW
- Unit
- kW
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
Charger operation status SUZUKI_CHGR_OP
- Request
22 16 19 - Service 22
DID 1619 - Module
745 → 74D - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | STANDBY | Standby |
1 | READY | Ready |
2 | STOP | Stopped |
3 | ROB_STOP | Stopped by request |
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
Charger output power SUZUKI_CHGR_OUT_P
- Request
22 16 1E - Service 22
DID 161E - Module
745 → 74D - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 200)- Range
- 0 to 327.675 kW
- Unit
- kW
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
Charger output power, target SUZUKI_CHGR_OUT_P_TGT
- Request
22 16 1E - Service 22
DID 161E - Module
745 → 74D - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 200)- Range
- 0 to 327.675 kW
- Unit
- kW
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
Charger supply voltage type SUZUKI_CHG_V_TYPE
- Request
22 16 1C - Service 22
DID 161C - Module
745 → 74D - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | NONE | None |
1 | V100 | 100V series |
2 | V200 | 200V series |
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
Control module voltage SUZUKI_CONTROL_MODULE_V
Pelican can show this parameter as the starter battery voltage.
- Request
21 00 - Service 21
PID 00 - Module
7DF - Every
1 s - Testing
Bits 392 to 399 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
Control system mode SUZUKI_CTRL_MODE
- Request
22 10 D1 - Service 22
DID 10D1 - Module
745 → 74D - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | NONE | None |
1 | DRIVING | Driving |
3 | CHARGING | Charging |
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
DC charger maximum current SUZUKI_DC_STA_A_MAX
- Request
22 16 79 - Service 22
DID 1679 - Module
745 → 74D - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 A
- Unit
- A
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
DC charger maximum power SUZUKI_DC_STA_P_MAX
- Request
22 16 6A - Service 22
DID 166A - Module
745 → 74D - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 kW
- Unit
- kW
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
DC charger maximum voltage SUZUKI_DC_STA_V_MAX
- Request
22 16 81 - Service 22
DID 1681 - Module
745 → 74D - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
DC charger present current SUZUKI_DC_STA_A
- Request
22 16 6C - Service 22
DID 166C - Module
745 → 74D - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 A
- Unit
- A
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
DC charger present voltage SUZUKI_DC_STA_V
- Request
22 16 6B - Service 22
DID 166B - Module
745 → 74D - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
DC high level communication state SUZUKI_HLC
- Request
22 16 66 - Service 22
DID 1666 - Module
745 → 74D - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
Distance since last battery cable disconnection SUZUKI_DIST_SINCE_BAT_DISC
- Request
22 10 6C - Service 22
DID 106C - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 km
- Unit
- km
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
Full charge capacity 1 SUZUKI_CAP_1
- Request
22 1D 3E - Service 22
DID 1D3E - Module
747 → 74F - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 Ah
- Unit
- Ah
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
Full charge capacity 2 SUZUKI_CAP_2
- Request
22 1D 3E - Service 22
DID 1D3E - Module
747 → 74F - Every
60 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 Ah
- Unit
- Ah
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
Full charge capacity 3 SUZUKI_CAP_3
- Request
22 1D 3E - Service 22
DID 1D3E - Module
747 → 74F - Every
60 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 Ah
- Unit
- Ah
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
Full charge capacity 4 SUZUKI_CAP_4
- Request
22 1D 3E - Service 22
DID 1D3E - Module
747 → 74F - Every
60 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 Ah
- Unit
- Ah
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
Full charge capacity 5 SUZUKI_CAP_5
- Request
22 1D 3E - Service 22
DID 1D3E - Module
747 → 74F - Every
60 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 Ah
- Unit
- Ah
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
Full charge capacity 6 SUZUKI_CAP_6
- Request
22 1D 3E - Service 22
DID 1D3E - Module
747 → 74F - Every
60 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 Ah
- Unit
- Ah
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
Full charge capacity 7 SUZUKI_CAP_7
- Request
22 1D 3E - Service 22
DID 1D3E - Module
747 → 74F - Every
60 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 Ah
- Unit
- Ah
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
Full charge capacity 8 SUZUKI_CAP_8
- Request
22 1D 3E - Service 22
DID 1D3E - Module
747 → 74F - Every
60 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 Ah
- Unit
- Ah
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
HV battery block 1 internal resistance SUZUKI_HVBAT_BLOCK_1_R
- Request
21 D0 - Service 21
PID D0 - Module
7E3 - Every
30 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mΩ
- Unit
- mΩ
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
HV battery block 1 voltage SUZUKI_HVBAT_BLOCK_1_V
- Request
21 CE - Service 21
PID CE - Module
7E3 - Every
1 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
HV battery block 2 internal resistance SUZUKI_HVBAT_BLOCK_2_R
- Request
21 D0 - Service 21
PID D0 - Module
7E3 - Every
30 s - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mΩ
- Unit
- mΩ
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
HV battery block 2 voltage SUZUKI_HVBAT_BLOCK_2_V
- Request
21 CE - Service 21
PID CE - Module
7E3 - Every
1 s - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
HV battery block 3 internal resistance SUZUKI_HVBAT_BLOCK_3_R
- Request
21 D0 - Service 21
PID D0 - Module
7E3 - Every
30 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mΩ
- Unit
- mΩ
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
HV battery block 3 voltage SUZUKI_HVBAT_BLOCK_3_V
- Request
21 CE - Service 21
PID CE - Module
7E3 - Every
1 s - Testing
Bits 56 to 71 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
HV battery block 4 internal resistance SUZUKI_HVBAT_BLOCK_4_R
- Request
21 D0 - Service 21
PID D0 - Module
7E3 - Every
30 s - Testing
Bits 144 to 151 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mΩ
- Unit
- mΩ
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
HV battery block 4 voltage SUZUKI_HVBAT_BLOCK_4_V
- Request
21 CE - Service 21
PID CE - Module
7E3 - Every
1 s - Testing
Bits 72 to 87 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
HV battery block 5 internal resistance SUZUKI_HVBAT_BLOCK_5_R
- Request
21 D0 - Service 21
PID D0 - Module
7E3 - Every
30 s - Testing
Bits 152 to 159 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mΩ
- Unit
- mΩ
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
HV battery block 5 voltage SUZUKI_HVBAT_BLOCK_5_V
- Request
21 CE - Service 21
PID CE - Module
7E3 - Every
1 s - Testing
Bits 88 to 103 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
HV battery block 6 internal resistance SUZUKI_HVBAT_BLOCK_6_R
- Request
21 D0 - Service 21
PID D0 - Module
7E3 - Every
30 s - Testing
Bits 160 to 167 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mΩ
- Unit
- mΩ
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
HV battery block 6 voltage SUZUKI_HVBAT_BLOCK_6_V
- Request
21 CE - Service 21
PID CE - Module
7E3 - Every
1 s - Testing
Bits 104 to 119 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
HV battery block 7 internal resistance SUZUKI_HVBAT_BLOCK_7_R
- Request
21 D0 - Service 21
PID D0 - Module
7E3 - Every
30 s - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mΩ
- Unit
- mΩ
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
HV battery block 7 voltage SUZUKI_HVBAT_BLOCK_7_V
- Request
21 CE - Service 21
PID CE - Module
7E3 - Every
1 s - Testing
Bits 120 to 135 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
HV battery block 8 internal resistance SUZUKI_HVBAT_BLOCK_8_R
- Request
21 D0 - Service 21
PID D0 - Module
7E3 - Every
30 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mΩ
- Unit
- mΩ
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
HV battery block 8 voltage SUZUKI_HVBAT_BLOCK_8_V
- Request
21 CE - Service 21
PID CE - Module
7E3 - Every
1 s - Testing
Bits 136 to 151 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
HV battery block 9 internal resistance SUZUKI_HVBAT_BLOCK_9_R
- Request
21 D0 - Service 21
PID D0 - Module
7E3 - Every
30 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mΩ
- Unit
- mΩ
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
HV battery block 9 voltage SUZUKI_HVBAT_BLOCK_9_V
- Request
21 CE - Service 21
PID CE - Module
7E3 - Every
1 s - Testing
Bits 152 to 167 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
HV battery block 10 internal resistance SUZUKI_HVBAT_BLOCK_10_R
- Request
21 D0 - Service 21
PID D0 - Module
7E3 - Every
30 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mΩ
- Unit
- mΩ
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
HV battery block 10 voltage SUZUKI_HVBAT_BLOCK_10_V
- Request
21 CE - Service 21
PID CE - Module
7E3 - Every
1 s - Testing
Bits 168 to 183 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
HV battery block 11 internal resistance SUZUKI_HVBAT_BLOCK_11_R
- Request
21 D0 - Service 21
PID D0 - Module
7E3 - Every
30 s - Testing
Bits 200 to 207 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mΩ
- Unit
- mΩ
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
HV battery block 11 voltage SUZUKI_HVBAT_BLOCK_11_V
- Request
21 CE - Service 21
PID CE - Module
7E3 - Every
1 s - Testing
Bits 184 to 199 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
HV battery block 12 internal resistance SUZUKI_HVBAT_BLOCK_12_R
- Request
21 D0 - Service 21
PID D0 - Module
7E3 - Every
30 s - Testing
Bits 208 to 215 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mΩ
- Unit
- mΩ
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
HV battery block 12 voltage SUZUKI_HVBAT_BLOCK_12_V
- Request
21 CE - Service 21
PID CE - Module
7E3 - Every
1 s - Testing
Bits 200 to 215 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
HV battery block 13 internal resistance SUZUKI_HVBAT_BLOCK_13_R
- Request
21 D0 - Service 21
PID D0 - Module
7E3 - Every
30 s - Testing
Bits 216 to 223 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mΩ
- Unit
- mΩ
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
HV battery block 13 voltage SUZUKI_HVBAT_BLOCK_13_V
- Request
21 CE - Service 21
PID CE - Module
7E3 - Every
1 s - Testing
Bits 216 to 231 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
HV battery block 14 internal resistance SUZUKI_HVBAT_BLOCK_14_R
- Request
21 D0 - Service 21
PID D0 - Module
7E3 - Every
30 s - Testing
Bits 224 to 231 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mΩ
- Unit
- mΩ
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
HV battery block 14 voltage SUZUKI_HVBAT_BLOCK_14_V
- Request
21 CE - Service 21
PID CE - Module
7E3 - Every
1 s - Testing
Bits 232 to 247 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
HV battery block count SUZUKI_HVBAT_BLOCKS
- Request
21 D0 - Service 21
PID D0 - Module
7E3 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
HV battery block voltage, highest SUZUKI_HVBAT_BLOCK_V_MAX
- Request
21 D0 - Service 21
PID D0 - Module
7E3 - Every
30 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
HV battery block voltage, lowest SUZUKI_HVBAT_BLOCK_V_MIN
- Request
21 D0 - Service 21
PID D0 - Module
7E3 - Every
30 s - Testing
Bits 72 to 87 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
HV battery block with the highest voltage SUZUKI_HVBAT_BLOCK_V_MAX_NO
- Request
21 D0 - Service 21
PID D0 - Module
7E3 - Every
30 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
HV battery block with the lowest voltage SUZUKI_HVBAT_BLOCK_V_MIN_NO
- Request
21 D0 - Service 21
PID D0 - Module
7E3 - Every
30 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
HV battery charge SUZUKI_HVBAT_SOC
Pelican can show this parameter as the state of charge.
- Request
21 CE - Service 21
PID CE - Module
7E3 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127.5 %
- Unit
- %
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
HV battery charge (displayed) SUZUKI_HVBAT_SOC_DISPLAY
Pelican can show this parameter as the state of charge.
- Request
22 17 39 - Service 22
DID 1739 - Module
745 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery charge (max) SUZUKI_HVBAT_SOC_MAX
- Request
22 10 6C - Service 22
DID 106C - Module
7D2 → 7DA - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 100 %
- Unit
- %
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery charge (min) SUZUKI_HVBAT_SOC_MIN
- Request
22 10 6C - Service 22
DID 106C - Module
7D2 → 7DA - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 100 %
- Unit
- %
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery charge power limit SUZUKI_HVBAT_CHG_LIM
- Request
21 CF - Service 21
PID CF - Module
7E3 - Every
5 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val − 64)- Range
- -64 to 191 kW
- Unit
- kW
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
HV battery charge spread SUZUKI_HVBAT_DELTA_SOC
- Request
21 CF - Service 21
PID CF - Module
7E3 - Every
5 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val ÷ 100)- Range
- 0 to 2.55 %
- Unit
- %
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
HV battery charge voltage SUZUKI_HVBAT_CHRG_V
- Request
22 16 09 - Service 22
DID 1609 - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 100 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery charge, hybrid control SUZUKI_HV_SOC
- Request
21 C3 - Service 21
PID C3 - Module
7E2 - Every
250 ms - Testing
Bits 144 to 151 of the reply, 8 bits.
- Formula
(val × 0.392)- Range
- 0 to 99.96 %
- Unit
- %
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
HV battery current SUZUKI_HVBAT_C
- Request
22 1F 9A - Service 22
DID 1F9A - Module
7D2 → 7DA - Every
500 ms - Testing
Bits 32 to 47 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 A
- Unit
- A
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery current SUZUKI_HVBAT_I
Pelican can show this parameter as the traction battery current.
- Request
21 CE - Service 21
PID CE - Module
7E3 - Every
1 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 A
- Unit
- A
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
HV battery DC inhibit time SUZUKI_HVBAT_DC_INHIBIT_TIME
- Request
21 D0 - Service 21
PID D0 - Module
7E3 - Every
30 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 s
- Unit
- s
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
HV battery discharge power limit SUZUKI_HVBAT_DISCHG_LIM
- Request
21 CF - Service 21
PID CF - Module
7E3 - Every
5 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val − 64)- Range
- -64 to 191 kW
- Unit
- kW
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
HV battery discharge power limit SUZUKI_WOUT
- Request
21 C3 - Service 21
PID C3 - Module
7E2 - Every
250 ms - Testing
Bits 152 to 159 of the reply, 8 bits.
- Formula
(val × 320)- Range
- 0 to 81600 W
- Unit
- W
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
HV battery fan motor voltage SUZUKI_HVBAT_FAN_V
- Request
21 CF - Service 21
PID CF - Module
7E3 - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val ÷ 5 − 25.6)- Range
- -25.6 to 25.4 V
- Unit
- V
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
HV battery fan speed SUZUKI_HVBAT_FAN
- Request
21 CF - Service 21
PID CF - Module
7E3 - Every
5 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
HV battery high charge time SUZUKI_HVBAT_HIGH_TIME
- Request
21 D0 - Service 21
PID D0 - Module
7E3 - Every
30 s - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 s
- Unit
- s
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
HV battery hot temperature time SUZUKI_HVBAT_HOT_TIME
- Request
21 D0 - Service 21
PID D0 - Module
7E3 - Every
30 s - Testing
Bits 56 to 71 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 s
- Unit
- s
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
HV battery intake air temperature SUZUKI_HVBAT_INTAKE_T
- Request
21 CF - Service 21
PID CF - Module
7E3 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 °C
- Unit
- °C
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
HV battery low charge time SUZUKI_HVBAT_LOW_TIME
- Request
21 D0 - Service 21
PID D0 - Module
7E3 - Every
30 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 s
- Unit
- s
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
HV battery maximum temperature SUZUKI_HVBAT_MAX_T
- Request
22 18 29 - Service 22
DID 1829 - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery minimum temperature SUZUKI_HVBAT_MIN_T
- Request
22 18 2A - Service 22
DID 182A - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery temperature 1 SUZUKI_HVBAT_T_1
- Request
21 CF - Service 21
PID CF - Module
7E3 - Every
5 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 °C
- Unit
- °C
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
HV battery temperature 2 SUZUKI_HVBAT_T_2
- Request
21 CF - Service 21
PID CF - Module
7E3 - Every
5 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 °C
- Unit
- °C
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
HV battery temperature 3 SUZUKI_HVBAT_T_3
- Request
21 CF - Service 21
PID CF - Module
7E3 - Every
5 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 °C
- Unit
- °C
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
HV battery voltage SUZUKI_HVBAT_V
- Request
22 1F 9A - Service 22
DID 1F9A - Module
7D2 → 7DA - Every
500 ms - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 156.25 ÷ 10000)- Range
- 0 to 1023 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
Last charge outcome code SUZUKI_CHG_OUTCOME
- Request
22 16 88 - Service 22
DID 1688 - Module
745 → 74D - Every
60 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
Main battery charging requested SUZUKI_CHARGE_REQ
- Request
21 C4 - Service 21
PID C4 - Module
7E2 - Every
250 ms - Testing
Bit 11 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
Main connector solenoid current SUZUKI_SMC_SOLENOID_CURRENT
- Request
21 A3 - Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
Main relay a, solenoid current SUZUKI_SLA_SOLENOID_CURRENT
- Request
21 A3 - Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
Main relay r solenoid current SUZUKI_SLR_SOLENOID_CURRENT
- Request
21 A3 - Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
Minimum permission power SUZUKI_CHG_P_PERMIT
- Request
22 16 A1 - Service 22
DID 16A1 - Module
745 → 74D - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 kW
- Unit
- kW
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
Plug-in switch status SUZUKI_PISW
- Request
22 16 69 - Service 22
DID 1669 - Module
745 → 74D - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
Power resource current SUZUKI_IB
- Request
21 C3 - Service 21
PID C3 - Module
7E2 - Every
250 ms - Testing
Bits 240 to 247 of the reply, 8 bits.
- Formula
(val × 2 − 256)- Range
- -256 to 254 A
- Unit
- A
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
Power resource voltage SUZUKI_VB
- Request
21 C3 - Service 21
PID C3 - Module
7E2 - Every
250 ms - Testing
Bits 224 to 231 of the reply, 8 bits.
- Formula
(val × 2)- Range
- 0 to 510 V
- Unit
- V
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
Regen cooperation SUZUKI_REGEN_COOPERATION
- Request
21 58 - Service 21
PID 58 - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
Regenerative operation SUZUKI_FR_REGEN_OPERATION
- Request
21 48 - Service 21
PID 48 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
Regenerative request SUZUKI_FR_REGEN_REQUEST
- Request
21 48 - Service 21
PID 48 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
Relay control solenoid current SUZUKI_SRC_SOLENOID_CURRENT
- Request
21 A3 - Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
Service contactor solenoid current SUZUKI_SSC_SOLENOID_CURRENT
- Request
21 A3 - Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
Short circuit wave highest value SUZUKI_SHORT_WAVE_V
- Request
21 C4 - Service 21
PID C4 - Module
7E2 - Every
250 ms - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val ÷ 51)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
State of charge SUZUKI_SOC
Pelican can show this parameter as the state of charge.
- Request
22 1F 5B - Service 22
DID 1F5B - Module
7D2 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
State of charge, battery ECU SUZUKI_SOC_747
- Request
22 1F 5B - Service 22
DID 1F5B - Module
747 → 74F - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2.55)- Range
- 0 to 100 %
- Unit
- %
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
State of charge, charging control SUZUKI_SOC_745
- Request
22 17 38 - Service 22
DID 1738 - Module
745 → 74D - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
System main relay 1 SUZUKI_SMR1
- Request
21 C4 - Service 21
PID C4 - Module
7E2 - Every
250 ms - Testing
Bit 63 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
System main relay 2 SUZUKI_SMR2
- Request
21 C4 - Service 21
PID C4 - Module
7E2 - Every
250 ms - Testing
Bit 62 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
System main relay 3 SUZUKI_SMR3
- Request
21 C4 - Service 21
PID C4 - Module
7E2 - Every
250 ms - Testing
Bit 61 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
Target charging current SUZUKI_CHG_A_TGT
- Request
22 16 6D - Service 22
DID 166D - Module
745 → 74D - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 A
- Unit
- A
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
Throttle position sensor voltage SUZUKI_THROTTLE_V
- Request
21 00 - Service 21
PID 00 - Module
7DF - Every
1 s - Testing
Bits 288 to 295 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
Battery › Cells
HV battery cell #01 voltage SUZUKI_HVBAT_C01_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #02 voltage SUZUKI_HVBAT_C02_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #03 voltage SUZUKI_HVBAT_C03_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #04 voltage SUZUKI_HVBAT_C04_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #05 voltage SUZUKI_HVBAT_C05_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #06 voltage SUZUKI_HVBAT_C06_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #07 voltage SUZUKI_HVBAT_C07_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #08 voltage SUZUKI_HVBAT_C08_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #09 voltage SUZUKI_HVBAT_C09_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #10 voltage SUZUKI_HVBAT_C10_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #11 voltage SUZUKI_HVBAT_C11_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #12 voltage SUZUKI_HVBAT_C12_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #13 voltage SUZUKI_HVBAT_C13_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #14 voltage SUZUKI_HVBAT_C14_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #15 voltage SUZUKI_HVBAT_C15_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #16 voltage SUZUKI_HVBAT_C16_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #17 voltage SUZUKI_HVBAT_C17_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 256 to 271 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #18 voltage SUZUKI_HVBAT_C18_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #19 voltage SUZUKI_HVBAT_C19_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #20 voltage SUZUKI_HVBAT_C20_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 304 to 319 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #21 voltage SUZUKI_HVBAT_C21_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 320 to 335 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #22 voltage SUZUKI_HVBAT_C22_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 336 to 351 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #23 voltage SUZUKI_HVBAT_C23_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 352 to 367 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #24 voltage SUZUKI_HVBAT_C24_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 368 to 383 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #25 voltage SUZUKI_HVBAT_C25_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 384 to 399 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #26 voltage SUZUKI_HVBAT_C26_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 400 to 415 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #27 voltage SUZUKI_HVBAT_C27_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 416 to 431 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #28 voltage SUZUKI_HVBAT_C28_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 432 to 447 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #29 voltage SUZUKI_HVBAT_C29_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 448 to 463 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #30 voltage SUZUKI_HVBAT_C30_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 464 to 479 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #31 voltage SUZUKI_HVBAT_C31_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 480 to 495 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #32 voltage SUZUKI_HVBAT_C32_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 496 to 511 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #33 voltage SUZUKI_HVBAT_C33_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 512 to 527 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #34 voltage SUZUKI_HVBAT_C34_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 528 to 543 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #35 voltage SUZUKI_HVBAT_C35_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 544 to 559 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #36 voltage SUZUKI_HVBAT_C36_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 560 to 575 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #37 voltage SUZUKI_HVBAT_C37_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 576 to 591 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #38 voltage SUZUKI_HVBAT_C38_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 592 to 607 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #39 voltage SUZUKI_HVBAT_C39_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 608 to 623 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #40 voltage SUZUKI_HVBAT_C40_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 624 to 639 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #41 voltage SUZUKI_HVBAT_C41_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 640 to 655 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #42 voltage SUZUKI_HVBAT_C42_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 656 to 671 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #43 voltage SUZUKI_HVBAT_C43_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 672 to 687 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #44 voltage SUZUKI_HVBAT_C44_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 688 to 703 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #45 voltage SUZUKI_HVBAT_C45_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 704 to 719 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #46 voltage SUZUKI_HVBAT_C46_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 720 to 735 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #47 voltage SUZUKI_HVBAT_C47_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 736 to 751 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #48 voltage SUZUKI_HVBAT_C48_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 752 to 767 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #49 voltage SUZUKI_HVBAT_C49_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 768 to 783 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #50 voltage SUZUKI_HVBAT_C50_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 784 to 799 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #51 voltage SUZUKI_HVBAT_C51_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 800 to 815 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #52 voltage SUZUKI_HVBAT_C52_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 816 to 831 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #53 voltage SUZUKI_HVBAT_C53_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 832 to 847 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #54 voltage SUZUKI_HVBAT_C54_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 848 to 863 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #55 voltage SUZUKI_HVBAT_C55_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 864 to 879 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #56 voltage SUZUKI_HVBAT_C56_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 880 to 895 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #57 voltage SUZUKI_HVBAT_C57_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 896 to 911 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #58 voltage SUZUKI_HVBAT_C58_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 912 to 927 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #59 voltage SUZUKI_HVBAT_C59_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 928 to 943 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #60 voltage SUZUKI_HVBAT_C60_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 944 to 959 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #61 voltage SUZUKI_HVBAT_C61_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 960 to 975 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #62 voltage SUZUKI_HVBAT_C62_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 976 to 991 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #63 voltage SUZUKI_HVBAT_C63_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 992 to 1,007 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #64 voltage SUZUKI_HVBAT_C64_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 1,008 to 1,023 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #65 voltage SUZUKI_HVBAT_C65_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 1,024 to 1,039 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #66 voltage SUZUKI_HVBAT_C66_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 1,040 to 1,055 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #67 voltage SUZUKI_HVBAT_C67_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 1,056 to 1,071 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #68 voltage SUZUKI_HVBAT_C68_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 1,072 to 1,087 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #69 voltage SUZUKI_HVBAT_C69_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 1,088 to 1,103 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #70 voltage SUZUKI_HVBAT_C70_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 1,104 to 1,119 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #71 voltage SUZUKI_HVBAT_C71_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 1,120 to 1,135 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #72 voltage SUZUKI_HVBAT_C72_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 1,136 to 1,151 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #73 voltage SUZUKI_HVBAT_C73_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 1,152 to 1,167 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #74 voltage SUZUKI_HVBAT_C74_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 1,168 to 1,183 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #75 voltage SUZUKI_HVBAT_C75_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 1,184 to 1,199 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #76 voltage SUZUKI_HVBAT_C76_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 1,200 to 1,215 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #77 voltage SUZUKI_HVBAT_C77_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 1,216 to 1,231 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #78 voltage SUZUKI_HVBAT_C78_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 1,232 to 1,247 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #79 voltage SUZUKI_HVBAT_C79_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 1,248 to 1,263 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #80 voltage SUZUKI_HVBAT_C80_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 1,264 to 1,279 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #81 voltage SUZUKI_HVBAT_C81_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 1,280 to 1,295 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #82 voltage SUZUKI_HVBAT_C82_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 1,296 to 1,311 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #83 voltage SUZUKI_HVBAT_C83_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 1,312 to 1,327 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #84 voltage SUZUKI_HVBAT_C84_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 1,328 to 1,343 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #85 voltage SUZUKI_HVBAT_C85_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 1,344 to 1,359 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #86 voltage SUZUKI_HVBAT_C86_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 1,360 to 1,375 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #87 voltage SUZUKI_HVBAT_C87_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 1,376 to 1,391 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #88 voltage SUZUKI_HVBAT_C88_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 1,392 to 1,407 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #89 voltage SUZUKI_HVBAT_C89_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 1,408 to 1,423 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #90 voltage SUZUKI_HVBAT_C90_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 1,424 to 1,439 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #91 voltage SUZUKI_HVBAT_C91_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 1,440 to 1,455 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #92 voltage SUZUKI_HVBAT_C92_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 1,456 to 1,471 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #93 voltage SUZUKI_HVBAT_C93_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 1,472 to 1,487 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #94 voltage SUZUKI_HVBAT_C94_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 1,488 to 1,503 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #95 voltage SUZUKI_HVBAT_C95_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 1,504 to 1,519 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
HV battery cell #96 voltage SUZUKI_HVBAT_C96_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 1,520 to 1,535 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
Battery › Modules › 01
HV battery module 01 voltage SUZUKI_HVBAT_CMU01_VOLT
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 13107)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
Battery › Modules › 02
HV battery module 02 voltage SUZUKI_HVBAT_CMU02_VOLT
- Request
22 18 2E - Service 22
DID 182E - Module
747 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 13107)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.