Transmission parameters
The Suzuki Swift has 21 transmission parameters.
● Confirmed◆ In testing○ Supported× Not supported
Gear SUZUKI_GEAR
- Request
21 85 - Service 21
PID 85 - Module
7E0 → 7E8 - Every
400 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 20
- Unit
- Number
In testing for 1988 to 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2009, 2019 to 2020, 2024.
Gear SUZUKI_GEAR_V2
- Request
22 16 21 - Service 22
DID 1621 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
Gear SUZUKI_GEAR_V3
- Request
22 DA 2E - Service 22
DID DA2E - Module
6F1 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
Lock up state SUZUKI_AT_LOCK_UP_STATE
- Request
22 16 20 - Service 22
DID 1620 - Module
700 → 708 - Every
1 s - Testing
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
Neutral control SUZUKI_NEUTRAL_CTRL
- Request
21 51 - Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 233 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
Neutral range status SUZUKI_N_RANGE_STS
- Request
21 51 - Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 232 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
Shift in drive SUZUKI_SHIFT_D
- Request
21 D3 - Service 21
PID D3 - Module
7E2 - Every
1 s - Testing
Bit 16 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
Shift position SUZUKI_SHIFT
- Request
22 10 61 - Service 22
DID 1061 - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | P | Park |
2 | R | Reverse |
4 | N | Neutral |
6 | D | Drive |
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
Shift position sensor voltage SUZUKI_SHIFT_POS_V
- Request
21 C3 - Service 21
PID C3 - Module
7E2 - Every
250 ms - Testing
Bits 280 to 287 of the reply, 8 bits.
- Formula
(val ÷ 51)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
Shift select sensor main voltage SUZUKI_SELECT_MAIN_V
- Request
21 C3 - Service 21
PID C3 - Module
7E2 - Every
250 ms - Testing
Bits 264 to 271 of the reply, 8 bits.
- Formula
(val ÷ 51)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
Shift select sensor sub voltage SUZUKI_SELECT_SUB_V
- Request
21 C3 - Service 21
PID C3 - Module
7E2 - Every
250 ms - Testing
Bits 272 to 279 of the reply, 8 bits.
- Formula
(val ÷ 51)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
Shift sensor main voltage SUZUKI_SHIFT_MAIN_V
- Request
21 C3 - Service 21
PID C3 - Module
7E2 - Every
250 ms - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
(val ÷ 51)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
Shift sensor sub voltage SUZUKI_SHIFT_SUB_V
- Request
21 C3 - Service 21
PID C3 - Module
7E2 - Every
250 ms - Testing
Bits 256 to 263 of the reply, 8 bits.
- Formula
(val ÷ 51)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2019, 2021 to 2023, 2025 to 2026. Not supported for 2020, 2024.
Torque converter lock-up SUZUKI_TQC_LOCKUP
Engages a clutch inside the torque converter to create a direct connection between the engine and transmission, reducing slippage and improving efficiency.
- Request
21 85 - Service 21
PID 85 - Module
7E0 → 7E8 - Every
400 ms - Testing
Bit 8 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2009, 2019 to 2020, 2024.
Torque converter lockup SUZUKI_TQ_CNVRT_LOCKUP
- Request
22 DA 22 - Service 22
DID DA22 - Module
6F1 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | OPEN | Open |
1 | CONTROL_LOW | Controlled low |
2 | CONTROL_HIGH | Controlled high |
3 | CLOSED_LOW | Closed low |
4 | CLOSED_HIGH | Closed high |
8 | TRANSITION_OPEN | Transition to open |
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
Torque converter speed SUZUKI_TQ_CNVRT_RPM
- Request
22 DA 2A - Service 22
DID DA2A - Module
6F1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
Transmission fluid temperature, pan SUZUKI_ATF_T_PAN
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 16 27 - Service 22
DID 1627 - Module
701 → 709 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 256 − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
Transmission fluid temperature, pan var.3 SUZUKI_ATF_T_PAN_V3
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 16 27 - Service 22
DID 1627 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 256 − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
Transmission output shaft speed SUZUKI_TRANS_SHAFT_RPM
- Request
22 DA 2A - Service 22
DID DA2A - Module
6F1 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
Transmission temperature, pan SUZUKI_ATF_PAN_T
Pelican can show this parameter as the transmission fluid temperature.
- Request
21 82 - Service 21
PID 82 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 256 − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.
Transmission temperature, torque converter SUZUKI_ATF_TQC_T
Pelican can show this parameter as the transmission fluid temperature.
- Request
21 82 - Service 21
PID 82 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 256 − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 2006, 2008, 2010 to 2018, 2021 to 2023, 2025 to 2026. Not supported for 2007, 2009, 2019 to 2020, 2024.