Toyota Corolla

Battery parameters

The Toyota Corolla has 271 battery parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

12V battery voltage COROLLA_12V_V_7D2Confirmed

Pelican can show this parameter as the starter battery voltage.

  • Request22 15 EE
  • Service 22DID 15EE
  • Module7D2 → 7DA
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Example reply from a 2024 Toyota Corolla.

Bits 0 to 7 of the reply, 8 bits.

0x2C = 44 → (44 × 0.31448 + 0.0125) = 13.84962 V

Formula
(val × 0.31448 + 0.0125)
Range
0 to 80.2 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

+BM voltage COROLLA_BM_VConfirmed

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 1988 to 2008, 2010 to 2011, 2013, 2015 to 2020, 2023 to 2026

Example reply from a 2022 Toyota Corolla.

Bits 56 to 71 of the reply, 16 bits.

0x2C31 = 11313 → (11313 × 5 ÷ 4096) = 13.809814 V

Formula
(val × 5 ÷ 4096)
Range
0 to 79.998 V
Unit
V

Confirmed for 2012, 2014, 2021 to 2022. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Supported for 2009. Not supported for 2010, 2023 to 2025.

1st turbocharger outlet pressure, control valve COROLLA_1ST_TRUBOCHARGER_P

  • Request22 11 CD
  • Service 22DID 11CD
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 300 kPa
Unit
kPa

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

2nd turbocharger outlet pressure COROLLA_2ND_TRUBOCHARGER_OUTLET_P

  • Request22 11 AF
  • Service 22DID 11AF
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 300 kPa
Unit
kPa

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

2nd turbocharger outlet pressure, control valve COROLLA_2ND_TRUBOCHARGER_P

  • Request22 11 CD
  • Service 22DID 11CD
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 300 kPa
Unit
kPa

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

12V battery current COROLLA_12V_CConfirmed

  • Request22 15 F7
  • Service 22DID 15F7
  • Module7D2 → 7DA
  • Every500 ms
  • Testing for 1988 to 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 38.147 ÷ 10000 − 125)
Range
-125 to 124 A
Unit
A

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

12V battery temperature COROLLA_12V_TConfirmed

  • Request22 15 F8
  • Service 22DID 15F8
  • Module7D2 → 7DA
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Example reply from a 2024 Toyota Corolla.

Bits 0 to 15 of the reply, 16 bits.

0x02EB = 747 → (747 ÷ 10 − 40) = 34.7 °C

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

12V battery voltage COROLLA_12V_V_7D2Confirmed

Pelican can show this parameter as the starter battery voltage.

  • Request22 15 EE
  • Service 22DID 15EE
  • Module7D2 → 7DA
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Example reply from a 2024 Toyota Corolla.

Bits 0 to 7 of the reply, 8 bits.

0x2C = 44 → (44 × 0.31448 + 0.0125) = 13.84962 V

Formula
(val × 0.31448 + 0.0125)
Range
0 to 80.2 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

Accumulated time of battery low COROLLA_ACCUMULATED_TIME_BAT

  • Request21 92
  • Service 21PID 92
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Accumulated time of battery too high COROLLA_ACCUMULATED_TIME_BAT_TOO

  • Request21 92
  • Service 21PID 92
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 88 to 103 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Air fuel sensor voltage, bank 1 sensor 1 COROLLA_AFS_VOLTAGE_B1S1Confirmed

  • Request21 04
  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2008, 2010 to 2011, 2013, 2015 to 2020, 2023 to 2026

Example reply from a 2022 Toyota Corolla.

Bits 32 to 47 of the reply, 16 bits.

0x9FFF = 40959 → (40959 × 7.99 ÷ 65535) = 4.993704 V

Formula
(val × 7.99 ÷ 65535)
Range
0 to 7.99 V
Unit
V

Confirmed for 2012, 2014, 2021 to 2022. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Supported for 2009. Not supported for 2010, 2023 to 2025.

Aux battery voltage COROLLA_AUX_BAT_V

  • Request22 10 02
  • Service 22DID 1002
  • Module7D2 → 7DA
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 61 ÷ 50000)
Range
0 to 79.95 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Aux. battery capacity after IG OFF COROLLA_AUX_BAT_CAP_AFTER_IG_OFF

  • Request22 15 E8
  • Service 22DID 15E8
  • Module700 → 708
  • Every30 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
(val − 128)
Range
-128 to 127 Ah
Unit
Ah

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Aux. battery capacity after IG ON COROLLA_AUX_BAT_CAP_AFTER_IG_ON

  • Request22 15 E8
  • Service 22DID 15E8
  • Module700 → 708
  • Every30 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
(val − 128)
Range
-128 to 127 Ah
Unit
Ah

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Auxiliary battery current COROLLA_AUXILIARY_BAT

  • Request22 18 02
  • Service 22DID 1802
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 2525 ÷ 13107 − 12500)
Range
-12500 to -12451 A
Unit
A

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Auxiliary battery temperature COROLLA_AUXILIARY_BAT_T

  • Request21 41
  • Service 21PID 41
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215
Unit
Number

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Auxiliary battery voltage COROLLA_AUX_V

Pelican can show this parameter as the starter battery voltage.

  • Request21 CF
  • Service 21PID CF
  • Module7E3 → 7EB
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
(val ÷ 5 − 25.6)
Range
-25.6 to 25.4 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Auxiliary battery voltage COROLLA_AUXILIARY_BAT_V

  • Request21 81
  • Service 21PID 81
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
(val × 47 ÷ 38550 − 40)
Range
-40 to 39.9 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Battery block 1 voltage COROLLA_BAT_BLOCK_V_V01

  • Request21 81
  • Service 21PID 81
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.0012205692)
Range
0 to 79.99 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Battery block 1 voltage COROLLA_BATTERY_BLOCK_VOL_V01

  • Request21 CE
  • Service 21PID CE
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Battery block 2 voltage COROLLA_BAT_BLOCK_V_V02

  • Request21 81
  • Service 21PID 81
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 0.0012205692)
Range
0 to 79.99 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Battery block 2 voltage COROLLA_BATTERY_BLOCK_VOL_V02

  • Request21 CE
  • Service 21PID CE
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 40 to 55 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Battery block 3 voltage COROLLA_BAT_BLOCK_V_V03

  • Request21 81
  • Service 21PID 81
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val × 0.0012205692)
Range
0 to 79.99 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Battery block 3 voltage COROLLA_BATTERY_BLOCK_VOL_V03

  • Request21 CE
  • Service 21PID CE
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Battery block 4 voltage COROLLA_BAT_BLOCK_V_V04

  • Request21 81
  • Service 21PID 81
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val × 0.0012205692)
Range
0 to 79.99 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Battery block 4 voltage COROLLA_BATTERY_BLOCK_VOL_V04

  • Request21 CE
  • Service 21PID CE
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 72 to 87 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Battery block 5 voltage COROLLA_BAT_BLOCK_V_V05

  • Request21 81
  • Service 21PID 81
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val × 0.0012205692)
Range
0 to 79.99 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Battery block 5 voltage COROLLA_BATTERY_BLOCK_VOL_V05

  • Request21 CE
  • Service 21PID CE
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 88 to 103 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Battery block 6 voltage COROLLA_BAT_BLOCK_V_V06

  • Request21 81
  • Service 21PID 81
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
(val × 0.0012205692)
Range
0 to 79.99 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Battery block 6 voltage COROLLA_BATTERY_BLOCK_VOL_V06

  • Request21 CE
  • Service 21PID CE
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Battery block 7 voltage COROLLA_BAT_BLOCK_V_V07

  • Request21 81
  • Service 21PID 81
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
(val × 0.0012205692)
Range
0 to 79.99 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Battery block 7 voltage COROLLA_BATTERY_BLOCK_VOL_V07

  • Request21 CE
  • Service 21PID CE
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Battery block 8 voltage COROLLA_BAT_BLOCK_V_V08

  • Request21 81
  • Service 21PID 81
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
(val × 0.0012205692)
Range
0 to 79.99 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Battery block 8 voltage COROLLA_BATTERY_BLOCK_VOL_V08

  • Request21 CE
  • Service 21PID CE
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 136 to 151 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Battery block 9 voltage COROLLA_BAT_BLOCK_V_V09

  • Request21 81
  • Service 21PID 81
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
(val × 0.0012205692)
Range
0 to 79.99 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Battery block 9 voltage COROLLA_BATTERY_BLOCK_VOL_V09

  • Request21 CE
  • Service 21PID CE
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 152 to 167 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Battery block 10 voltage COROLLA_BATTERY_BLOCK_VOL_V10

  • Request21 CE
  • Service 21PID CE
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 168 to 183 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Battery block 10 voltage, raw count COROLLA_BAT_BLOCK_V_V10_RAW

  • Request21 81
  • Service 21PID 81
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 144 to 159 of the reply, 16 bits.

Formula
(val × 7999 ÷ 6553500)
Range
0 to 79.99
Unit
Number

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Battery block 11 voltage COROLLA_BAT_BLOCK_V_V11

  • Request21 81
  • Service 21PID 81
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 160 to 175 of the reply, 16 bits.

Formula
(val × 0.0012205692)
Range
0 to 79.99 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Battery block 11 voltage COROLLA_BATTERY_BLOCK_VOL_V11

  • Request21 CE
  • Service 21PID CE
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 184 to 199 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Battery block 12 voltage COROLLA_BAT_BLOCK_V_V12

  • Request21 81
  • Service 21PID 81
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
(val × 0.0012205692)
Range
0 to 79.99 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Battery block 12 voltage COROLLA_BATTERY_BLOCK_VOL_V12

  • Request21 CE
  • Service 21PID CE
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 200 to 215 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Battery block 13 voltage COROLLA_BAT_BLOCK_V_V13

  • Request21 81
  • Service 21PID 81
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
(val × 0.0012205692)
Range
0 to 79.99 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Battery block 13 voltage COROLLA_BATTERY_BLOCK_VOL_V13

  • Request21 CE
  • Service 21PID CE
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 216 to 231 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Battery block 14 voltage COROLLA_BAT_BLOCK_V_V14

  • Request21 81
  • Service 21PID 81
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
(val × 0.0012205692)
Range
0 to 79.99 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Battery block 14 voltage COROLLA_BATTERY_BLOCK_VOL_V14

  • Request21 CE
  • Service 21PID CE
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Battery block 15 voltage COROLLA_BATTERY_BLOCK_VOL_V15

  • Request21 CE
  • Service 21PID CE
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 248 to 263 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Battery block 16 voltage COROLLA_BAT_BLOCK_V_V16

  • Request21 81
  • Service 21PID 81
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 240 to 255 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Battery block 17 voltage COROLLA_BAT_BLOCK_V_V17

  • Request21 81
  • Service 21PID 81
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 256 to 271 of the reply, 16 bits.

Formula
(val × 7999 ÷ 6553500)
Range
0 to 79.99 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Battery block number with, maximum voltage COROLLA_BAT_BLOCK_NUMBER_MAX_V

  • Request21 92
  • Service 21PID 92
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val + 1)
Range
0 to 256
Unit
Number

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Battery block number with, minimum voltage COROLLA_BAT_BLOCK_NUMBER_MIN_V

  • Request21 92
  • Service 21PID 92
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val + 1)
Range
0 to 256
Unit
Number

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Battery block, maximum voltage COROLLA_BAT_BLOCK_MAX_V

  • Request21 92
  • Service 21PID 92
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
(val × 0.0012205692)
Range
0 to 79.99 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Battery block, minimum voltage COROLLA_BAT_BLOCK_MIN_V

  • Request21 92
  • Service 21PID 92
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.0012205692)
Range
0 to 79.99 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Battery current COROLLA_BAT_CURRENTConfirmed

  • Request21 42
  • Service 21PID 42
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1988 to 2008, 2010 to 2020, 2023 to 2026

Example reply from a 2022 Toyota Corolla.

Bits 0 to 15 of the reply, 16 bits.

0x2CFE = 11518 → (11518 × 50 ÷ 13107 − 125) = -81.061646 A

Formula
(val × 50 ÷ 13107 − 125)
Range
-125 to 124.9 A
Unit
A

Confirmed for 2009, 2021 to 2022. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2010, 2012, 2014, 2023 to 2025.

Battery current COROLLA_BAT_CURRENT_700

  • Request22 15 F7
  • Service 22DID 15F7
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 49 ÷ 12850 − 125)
Range
-125 to 124.9 A
Unit
A

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Battery status of full charge COROLLA_BAT_STAT_FULL_CHG

  • Request22 15 E5
  • Service 22DID 15E5
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 255 ÷ 2)
Range
0 to 32512.5 Ah
Unit
Ah

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Battery temperature COROLLA_BAT_TConfirmed

  • Request21 42
  • Service 21PID 42
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1988 to 2008, 2010 to 2020, 2023 to 2026

Example reply from a 2022 Toyota Corolla.

Bits 16 to 31 of the reply, 16 bits.

0x0000 = 0 → 0 °C

Formula
val
Range
0 to 6513.5 °C
Unit
°C

Confirmed for 2021 to 2022. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Supported for 2009. Not supported for 2010, 2012, 2014, 2023 to 2025.

Battery temperature COROLLA_BAT_T_700

  • Request22 15 F8
  • Service 22DID 15F8
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Battery temperature COROLLA_BAT_T_700_2

  • Request22 1F F8
  • Service 22DID 1FF8
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 9 ÷ 50 − 40)
Range
-40 to 11756.3 °F
Unit
°F

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Battery voltage COROLLA_12V_VConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Request22 10 02
  • Service 22DID 1002
  • Module700 → 708
  • Every1 s
  • Testing for 1988 to 2022, 2026

Example reply from a 2025 Toyota Corolla.

Bits 0 to 15 of the reply, 16 bits.

0x2B90 = 11152 → (11152 × 12.207 ÷ 10000) = 13.613246 V

Formula
(val × 12.207 ÷ 10000)
Range
0 to 79 V
Unit
V

Confirmed for 2023 to 2025. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2022.

Battery voltage COROLLA_BAT_VConfirmed

  • Request21 13
  • Service 21PID 13
  • Module7C0 → 7C8
  • Every1 s
  • Testing for 1988 to 2008, 2010 to 2011, 2013, 2015 to 2026

Example reply from a 2014 Toyota Corolla.

Bits 0 to 7 of the reply, 8 bits.

0x87 = 135 → (135 ÷ 10) = 13.5 V

Formula
(val ÷ 10)
Range
0 to 25.5 V
Unit
V

Confirmed for 2009, 2012, 2014. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2010, 2021 to 2025.

Battery voltage COROLLA_BATTERY_VOLTAGE_7E0Confirmed

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2008, 2010 to 2011, 2013, 2015 to 2020, 2023 to 2026

Bits 208 to 223 of the reply, 16 bits.

Formula
val
Range
0 to 65.535 V
Unit
V

Confirmed for 2021 to 2022. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Supported for 2009, 2012, 2014. Not supported for 2010, 2023 to 2025.

Boost converter carrier frequency COROLLA_CONV_CARRIER

  • Request21 C4
  • Service 21PID C4
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bit 71 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Boost converter gate COROLLA_CONV_GATE

  • Request21 C4
  • Service 21PID C4
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bit 66 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Boost converter input voltage COROLLA_VL

  • Request21 C4
  • Service 21PID C4
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
(val × 2)
Range
0 to 510 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Boost converter output voltage COROLLA_VH

  • Request21 C4
  • Service 21PID C4
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 2)
Range
0 to 510 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Boost converter pressure ratio COROLLA_BOOST_RATIO

  • Request21 C4
  • Service 21PID C4
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
(val × 0.392)
Range
0 to 99.96 %
Unit
%

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Boost converter temperature COROLLA_CONV_T

  • Request21 C4
  • Service 21PID C4
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Charge contactor current COROLLA_SCC_SOLENOID_CURRENT

  • Request21 A3
  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Charging integrated current of aux. battery COROLLA_CHG_INTEGRATED

  • Request22 15 E8
  • Service 22DID 15E8
  • Module700 → 708
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 10)
Range
0 to 429496729.5 Ah
Unit
Ah

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Request01 42
  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65535 V
Unit
V

Confirmed for 2008 to 2009, 2011 to 2017, 2020 to 2022, 2025. Supported for 2010, 2018 to 2019, 2023 to 2024, 2026.

Dark current of battery COROLLA_DARK_CURRENT_BAT

  • Request22 15 E7
  • Service 22DID 15E7
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

DC-DC converter high side voltage COROLLA_DC_DC_CONV_HIGH_SIDE_V

  • Request22 11 1E
  • Service 22DID 111E
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 1220703 ÷ 10000000)
Range
0 to 7999 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

DC-DC converter low side voltage COROLLA_DC_DC_CONV_LOW_SIDE_V

  • Request22 11 1D
  • Service 22DID 111D
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 1953 ÷ 25000)
Range
0 to 19.92 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

DC-DC converter, target voltage before charging COROLLA_DC_DC_CONV_TGT_V

  • Request22 11 1F
  • Service 22DID 111F
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 1220703 ÷ 10000000)
Range
0 to 7999 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Delta SOC COROLLA_DELTA_SOC

  • Request21 98
  • Service 21PID 98
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127 %
Unit
%

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Discharging integrated current of aux. battery COROLLA_DISCHARGING

  • Request22 15 E8
  • Service 22DID 15E8
  • Module700 → 708
  • Every30 s
  • Testing

Bits 32 to 63 of the reply, 32 bits.

Formula
(val ÷ 10)
Range
0 to 429496729.5 Ah
Unit
Ah

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Distance since last battery cable disconnection COROLLA_DIST_SINCE_BAT_DISCConfirmed

  • Request22 10 6C
  • Service 22DID 106C
  • Module700 → 708
  • Every1 s
  • Testing for 1988 to 2022, 2026

Example reply from a 2025 Toyota Corolla.

Bits 0 to 15 of the reply, 16 bits.

0x704A = 28746 → 28,746 km

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2023 to 2025. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2022.

Engine control module control mode, driving control mode=1,current sensor offset mode=2,external charge control mode=3,power supply end mode=4 COROLLA_ENG_CTRL_MODULE_CTRL_1_2_3_4

  • Request21 9B
  • Service 21PID 9B
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

High voltage battery charge control, kw COROLLA_HVBAT_CHG_CTRL_KW

  • Request21 98
  • Service 21PID 98
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val ÷ 2 − 64)
Range
-64 to 63.5
Unit
Number

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

High voltage battery discharge control, kw COROLLA_HVBAT_DCHG_CTRL_KW

  • Request21 98
  • Service 21PID 98
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
(val ÷ 2 − 64)
Range
-64 to 63.5
Unit
Number

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

High voltage battery intake air temperature COROLLA_HVBAT_IAT

  • Request21 87
  • Service 21PID 87
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.0039047837 − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

HV battery block 1 internal resistance COROLLA_HVBAT_BLOCK_1_R

  • Request21 D0
  • Service 21PID D0
  • Module7E3 → 7EB
  • Every30 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val
Range
0 to 255 mΩ
Unit
mΩ

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

HV battery block 1 voltage COROLLA_HVBAT_BLOCK_1_V

  • Request21 CE
  • Service 21PID CE
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

HV battery block 2 internal resistance COROLLA_HVBAT_BLOCK_2_R

  • Request21 D0
  • Service 21PID D0
  • Module7E3 → 7EB
  • Every30 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val
Range
0 to 255 mΩ
Unit
mΩ

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

HV battery block 2 voltage COROLLA_HVBAT_BLOCK_2_V

  • Request21 CE
  • Service 21PID CE
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 40 to 55 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

HV battery block 3 internal resistance COROLLA_HVBAT_BLOCK_3_R

  • Request21 D0
  • Service 21PID D0
  • Module7E3 → 7EB
  • Every30 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 255 mΩ
Unit
mΩ

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

HV battery block 3 voltage COROLLA_HVBAT_BLOCK_3_V

  • Request21 CE
  • Service 21PID CE
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

HV battery block 4 internal resistance COROLLA_HVBAT_BLOCK_4_R

  • Request21 D0
  • Service 21PID D0
  • Module7E3 → 7EB
  • Every30 s
  • Testing

Bits 144 to 151 of the reply, 8 bits.

Formula
val
Range
0 to 255 mΩ
Unit
mΩ

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

HV battery block 4 voltage COROLLA_HVBAT_BLOCK_4_V

  • Request21 CE
  • Service 21PID CE
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 72 to 87 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

HV battery block 5 internal resistance COROLLA_HVBAT_BLOCK_5_R

  • Request21 D0
  • Service 21PID D0
  • Module7E3 → 7EB
  • Every30 s
  • Testing

Bits 152 to 159 of the reply, 8 bits.

Formula
val
Range
0 to 255 mΩ
Unit
mΩ

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

HV battery block 5 voltage COROLLA_HVBAT_BLOCK_5_V

  • Request21 CE
  • Service 21PID CE
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 88 to 103 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

HV battery block 6 internal resistance COROLLA_HVBAT_BLOCK_6_R

  • Request21 D0
  • Service 21PID D0
  • Module7E3 → 7EB
  • Every30 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val
Range
0 to 255 mΩ
Unit
mΩ

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

HV battery block 6 voltage COROLLA_HVBAT_BLOCK_6_V

  • Request21 CE
  • Service 21PID CE
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

HV battery block 7 internal resistance COROLLA_HVBAT_BLOCK_7_R

  • Request21 D0
  • Service 21PID D0
  • Module7E3 → 7EB
  • Every30 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val
Range
0 to 255 mΩ
Unit
mΩ

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

HV battery block 7 voltage COROLLA_HVBAT_BLOCK_7_V

  • Request21 CE
  • Service 21PID CE
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

HV battery block 8 internal resistance COROLLA_HVBAT_BLOCK_8_R

  • Request21 D0
  • Service 21PID D0
  • Module7E3 → 7EB
  • Every30 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val
Range
0 to 255 mΩ
Unit
mΩ

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

HV battery block 8 voltage COROLLA_HVBAT_BLOCK_8_V

  • Request21 CE
  • Service 21PID CE
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 136 to 151 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

HV battery block 9 internal resistance COROLLA_HVBAT_BLOCK_9_R

  • Request21 D0
  • Service 21PID D0
  • Module7E3 → 7EB
  • Every30 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val
Range
0 to 255 mΩ
Unit
mΩ

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

HV battery block 9 voltage COROLLA_HVBAT_BLOCK_9_V

  • Request21 CE
  • Service 21PID CE
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 152 to 167 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

HV battery block 10 internal resistance COROLLA_HVBAT_BLOCK_10_R

  • Request21 D0
  • Service 21PID D0
  • Module7E3 → 7EB
  • Every30 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 255 mΩ
Unit
mΩ

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

HV battery block 10 voltage COROLLA_HVBAT_BLOCK_10_V

  • Request21 CE
  • Service 21PID CE
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 168 to 183 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

HV battery block 11 internal resistance COROLLA_HVBAT_BLOCK_11_R

  • Request21 D0
  • Service 21PID D0
  • Module7E3 → 7EB
  • Every30 s
  • Testing

Bits 200 to 207 of the reply, 8 bits.

Formula
val
Range
0 to 255 mΩ
Unit
mΩ

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

HV battery block 11 voltage COROLLA_HVBAT_BLOCK_11_V

  • Request21 CE
  • Service 21PID CE
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 184 to 199 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

HV battery block 12 internal resistance COROLLA_HVBAT_BLOCK_12_R

  • Request21 D0
  • Service 21PID D0
  • Module7E3 → 7EB
  • Every30 s
  • Testing

Bits 208 to 215 of the reply, 8 bits.

Formula
val
Range
0 to 255 mΩ
Unit
mΩ

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

HV battery block 12 voltage COROLLA_HVBAT_BLOCK_12_V

  • Request21 CE
  • Service 21PID CE
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 200 to 215 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

HV battery block 13 internal resistance COROLLA_HVBAT_BLOCK_13_R

  • Request21 D0
  • Service 21PID D0
  • Module7E3 → 7EB
  • Every30 s
  • Testing

Bits 216 to 223 of the reply, 8 bits.

Formula
val
Range
0 to 255 mΩ
Unit
mΩ

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

HV battery block 13 voltage COROLLA_HVBAT_BLOCK_13_V

  • Request21 CE
  • Service 21PID CE
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 216 to 231 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

HV battery block 14 internal resistance COROLLA_HVBAT_BLOCK_14_R

  • Request21 D0
  • Service 21PID D0
  • Module7E3 → 7EB
  • Every30 s
  • Testing

Bits 224 to 231 of the reply, 8 bits.

Formula
val
Range
0 to 255 mΩ
Unit
mΩ

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

HV battery block 14 voltage COROLLA_HVBAT_BLOCK_14_V

  • Request21 CE
  • Service 21PID CE
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

HV battery block count COROLLA_HVBAT_BLOCKS

  • Request21 D0
  • Service 21PID D0
  • Module7E3 → 7EB
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

HV battery block voltage, highest COROLLA_HVBAT_BLOCK_V_MAX

  • Request21 D0
  • Service 21PID D0
  • Module7E3 → 7EB
  • Every30 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

HV battery block voltage, lowest COROLLA_HVBAT_BLOCK_V_MIN

  • Request21 D0
  • Service 21PID D0
  • Module7E3 → 7EB
  • Every30 s
  • Testing

Bits 72 to 87 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

HV battery block with the highest voltage COROLLA_HVBAT_BLOCK_V_MAX_NO

  • Request21 D0
  • Service 21PID D0
  • Module7E3 → 7EB
  • Every30 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

HV battery block with the lowest voltage COROLLA_HVBAT_BLOCK_V_MIN_NO

  • Request21 D0
  • Service 21PID D0
  • Module7E3 → 7EB
  • Every30 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

HV battery charge COROLLA_HVBAT_SOC

Pelican can show this parameter as the state of charge.

  • Request21 CE
  • Service 21PID CE
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127.5 %
Unit
%

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

HV battery charge power limit COROLLA_HVBAT_CHG_LIM

  • Request21 CF
  • Service 21PID CF
  • Module7E3 → 7EB
  • Every5 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val − 64)
Range
-64 to 191 kW
Unit
kW

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

HV battery charge spread COROLLA_HVBAT_DELTA_SOC

  • Request21 CF
  • Service 21PID CF
  • Module7E3 → 7EB
  • Every5 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
(val ÷ 100)
Range
0 to 2.55 %
Unit
%

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

HV battery charge voltage COROLLA_HVBAT_CHRG_V

  • Request22 16 09
  • Service 22DID 1609
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 100 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

HV battery charge, displayed COROLLA_HVBAT_SOC_DISPLAY

Pelican can show this parameter as the state of charge.

  • Request22 17 39
  • Service 22DID 1739
  • Module745 → 74D
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

HV battery charge, hybrid control COROLLA_HV_SOC

  • Request21 C3
  • Service 21PID C3
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 144 to 151 of the reply, 8 bits.

Formula
(val × 0.392)
Range
0 to 99.96 %
Unit
%

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

HV battery charge, maximum COROLLA_HVBAT_SOC_MAXConfirmed

  • Request22 10 6C
  • Service 22DID 106C
  • Module7D2 → 7DA
  • Every5 s
  • Testing for 1988 to 2023, 2025 to 2026

Example reply from a 2024 Toyota Corolla.

Bits 8 to 15 of the reply, 8 bits.

0x72 = 114 → (114 ÷ 2) = 57 %

Formula
(val ÷ 2)
Range
0 to 100 %
Unit
%

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery charge, minimum COROLLA_HVBAT_SOC_MINConfirmed

  • Request22 10 6C
  • Service 22DID 106C
  • Module7D2 → 7DA
  • Every5 s
  • Testing for 1988 to 2023, 2025 to 2026

Example reply from a 2024 Toyota Corolla.

Bits 16 to 23 of the reply, 8 bits.

0x43 = 67 → (67 ÷ 2) = 33.5 %

Formula
(val ÷ 2)
Range
0 to 100 %
Unit
%

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery current COROLLA_HVBAT_CConfirmed

  • Request22 1F 9A
  • Service 22DID 1F9A
  • Module7D2 → 7DA
  • Every500 ms
  • Testing for 1988 to 2023, 2025 to 2026

Example reply from a 2024 Toyota Corolla.

Bits 32 to 47 of the reply, 16 bits. The value is signed.

0xFFEF = -17 → (-17 ÷ 10) = -1.7 A

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 A
Unit
A

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery current COROLLA_HVBAT_I

Pelican can show this parameter as the traction battery current.

  • Request21 CE
  • Service 21PID CE
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 A
Unit
A

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

HV battery DC inhibit time COROLLA_HVBAT_DC_INHIBIT_TIME

  • Request21 D0
  • Service 21PID D0
  • Module7E3 → 7EB
  • Every30 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

HV battery discharge power limit COROLLA_HVBAT_DISCHG_LIM

  • Request21 CF
  • Service 21PID CF
  • Module7E3 → 7EB
  • Every5 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val − 64)
Range
-64 to 191 kW
Unit
kW

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

HV battery discharge power limit COROLLA_WOUT

  • Request21 C3
  • Service 21PID C3
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 152 to 159 of the reply, 8 bits.

Formula
(val × 320)
Range
0 to 81600 W
Unit
W

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

HV battery fan motor voltage COROLLA_HVBAT_FAN_V

  • Request21 CF
  • Service 21PID CF
  • Module7E3 → 7EB
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val ÷ 5 − 25.6)
Range
-25.6 to 25.4 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

HV battery fan speed COROLLA_HVBAT_FAN

  • Request21 CF
  • Service 21PID CF
  • Module7E3 → 7EB
  • Every5 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

HV battery high charge time COROLLA_HVBAT_HIGH_TIME

  • Request21 D0
  • Service 21PID D0
  • Module7E3 → 7EB
  • Every30 s
  • Testing

Bits 40 to 55 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

HV battery hot temperature time COROLLA_HVBAT_HOT_TIME

  • Request21 D0
  • Service 21PID D0
  • Module7E3 → 7EB
  • Every30 s
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

HV battery intake air temperature COROLLA_HVBAT_INTAKE_T

  • Request21 CF
  • Service 21PID CF
  • Module7E3 → 7EB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 °C
Unit
°C

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

HV battery low charge time COROLLA_HVBAT_LOW_TIME

  • Request21 D0
  • Service 21PID D0
  • Module7E3 → 7EB
  • Every30 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

HV battery maximum temperature COROLLA_HVBAT_MAX_T

  • Request22 18 29
  • Service 22DID 1829
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

HV battery minimum temperature COROLLA_HVBAT_MIN_T

  • Request22 18 2A
  • Service 22DID 182A
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

HV battery temperature 1 COROLLA_HVBAT_T_1

  • Request21 CF
  • Service 21PID CF
  • Module7E3 → 7EB
  • Every5 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 °C
Unit
°C

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

HV battery temperature 2 COROLLA_HVBAT_T_2

  • Request21 CF
  • Service 21PID CF
  • Module7E3 → 7EB
  • Every5 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 °C
Unit
°C

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

HV battery temperature 3 COROLLA_HVBAT_T_3

  • Request21 CF
  • Service 21PID CF
  • Module7E3 → 7EB
  • Every5 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 °C
Unit
°C

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

HV battery voltage COROLLA_HVBAT_VConfirmed

  • Request22 1F 9A
  • Service 22DID 1F9A
  • Module7D2 → 7DA
  • Every500 ms
  • Testing for 1988 to 2023, 2025 to 2026

Example reply from a 2024 Toyota Corolla.

Bits 16 to 31 of the reply, 16 bits.

0x3240 = 12864 → (12864 × 156.25 ÷ 10000) = 201 V

Formula
(val × 156.25 ÷ 10000)
Range
0 to 1023 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

Hybrid battery 1 fan COROLLA_HYBRID_BAT_1_FAN

  • Request22 18 02
  • Service 22DID 1802
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127 %
Unit
%

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Hybrid battery temperature 1 COROLLA_HYBRID_BAT_T_1

  • Request22 18 14
  • Service 22DID 1814
  • Module7D2 → 7DA
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 458 ÷ 65535 − 58)
Range
-58 to 400 °F
Unit
°F

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Hybrid battery temperature 2 COROLLA_HYBRID_BAT_T_2

  • Request22 18 14
  • Service 22DID 1814
  • Module7D2 → 7DA
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val × 9 ÷ 5 − 58)
Range
-58 to 401 °F
Unit
°F

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Hybrid battery temperature 3 COROLLA_HYBRID_BAT_T_3

  • Request22 18 14
  • Service 22DID 1814
  • Module7D2 → 7DA
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val × 458 ÷ 65535 − 58)
Range
-58 to 400 °F
Unit
°F

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Initial engine battery voltage lower limit COROLLA_INITIAL_ENG_BAT_V_LO

  • Request22 15 F6
  • Service 22DID 15F6
  • Module700 → 708
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Input over-voltage to converter COROLLA_OVERVOLTAGE_INPUT

  • Request21 74
  • Service 21PID 74
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bit 33 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Input over-voltage to inverter COROLLA_OVERVOLTAGE_INPUT_INVERTER

  • Request21 74
  • Service 21PID 74
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bit 34 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Main battery charging requested COROLLA_CHARGE_REQ

  • Request21 C4
  • Service 21PID C4
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Main connector solenoid current COROLLA_SMC_SOLENOID_CURRENT

  • Request21 A3
  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Main relay a, solenoid current COROLLA_SLA_SOLENOID_CURRENT

  • Request21 A3
  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Main relay r solenoid current COROLLA_SLR_SOLENOID_CURRENT

  • Request21 A3
  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Number of battery blocks COROLLA_NUM_BAT_BLOCKS

  • Request21 92
  • Service 21PID 92
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Output speed sensor voltage COROLLA_NOUT_SENS_VConfirmed

  • Request21 81
  • Service 21PID 81
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2011, 2013, 2015 to 2020, 2023 to 2026

Example reply from a 2022 Toyota Corolla.

Bits 40 to 55 of the reply, 16 bits.

0x0000 = 0 → (0 ÷ 13107) = 0 V

Formula
(val ÷ 13107)
Range
0 to 4.999 V
Unit
V

Confirmed for 2012, 2014, 2021 to 2022. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2023 to 2025.

Power resource current COROLLA_IB

  • Request21 C3
  • Service 21PID C3
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 240 to 247 of the reply, 8 bits.

Formula
(val × 2 − 256)
Range
-256 to 254 A
Unit
A

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Power resource voltage COROLLA_VB

  • Request21 C3
  • Service 21PID C3
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 224 to 231 of the reply, 8 bits.

Formula
(val × 2)
Range
0 to 510 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Regen cooperation COROLLA_REGEN_COOPERATION

  • Request21 58
  • Service 21PID 58
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Regenerative operation COROLLA_FR_REGEN_OPERATION

  • Request21 48
  • Service 21PID 48
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Regenerative request COROLLA_FR_REGEN_REQUEST

  • Request21 48
  • Service 21PID 48
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Relay control solenoid current COROLLA_SRC_SOLENOID_CURRENT

  • Request21 A3
  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Service contactor solenoid current COROLLA_SSC_SOLENOID_CURRENT

  • Request21 A3
  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Short circuit wave highest value COROLLA_SHORT_WAVE_V

  • Request21 C4
  • Service 21PID C4
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
(val ÷ 51)
Range
0 to 5 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Sleep time of battery sensor COROLLA_SLEEP_TIME_BATSENS

  • Request22 15 F0
  • Service 22DID 15F0
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 h
Unit
h

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

SOC at ignition on COROLLA_SOC_AFTER_IG_ON

  • Request21 98
  • Service 21PID 98
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127 %
Unit
%

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

SOC max COROLLA_SOC_MAX

  • Request21 98
  • Service 21PID 98
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127 %
Unit
%

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

SOC min COROLLA_SOC_MIN

  • Request21 98
  • Service 21PID 98
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127 %
Unit
%

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

State of charge COROLLA_SOCConfirmed

Pelican can show this parameter as the state of charge.

  • Request22 1F 5B
  • Service 22DID 1F5B
  • Module7D2 → 7DA
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Example reply from a 2024 Toyota Corolla.

Bits 0 to 7 of the reply, 8 bits.

0x5C = 92 → (92 × 100 ÷ 255) = 36.078431 %

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

State of charge, all bat COROLLA_ST_CHG_ALL_BAT

  • Request21 01
  • Service 21PID 01
  • Module7E2 → 7EA
  • Every30 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

System main relay 1 COROLLA_SMR1

  • Request21 C4
  • Service 21PID C4
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bit 63 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

System main relay 2 COROLLA_SMR2

  • Request21 C4
  • Service 21PID C4
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bit 62 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

System main relay 3 COROLLA_SMR3

  • Request21 C4
  • Service 21PID C4
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bit 61 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Turbine speed sensor voltage COROLLA_NT_SENS_VConfirmed

  • Request21 81
  • Service 21PID 81
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2011, 2013, 2015 to 2020, 2023 to 2026

Example reply from a 2022 Toyota Corolla.

Bits 8 to 23 of the reply, 16 bits.

0x8022 = 32802 → (32802 ÷ 13107) = 2.502632 V

Formula
(val ÷ 13107)
Range
0 to 4.999 V
Unit
V

Confirmed for 2012, 2014, 2021 to 2022. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2023 to 2025.

Vh-voltage after boosting COROLLA_VH_V_AFTER_BOOSTING

  • Request22 10 B0
  • Service 22DID 10B0
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 2)
Range
0 to 32767 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Vh-voltage after boosting COROLLA_VH_V_AFTER_BOOSTING_7E2

  • Request21 74
  • Service 21PID 74
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
(val ÷ 2)
Range
0 to 32767 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Vl-voltage before boosting COROLLA_VL_V_BEFORE_BOOSTING

  • Request22 10 B0
  • Service 22DID 10B0
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2)
Range
0 to 32767 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Vl-voltage before boosting COROLLA_VL_V_BEFORE_BOOSTING_7E2

  • Request21 74
  • Service 21PID 74
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 40 to 55 of the reply, 16 bits.

Formula
(val ÷ 2)
Range
0 to 32767 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Voltage of battery sensor COROLLA_V_BATSENS

  • Request22 15 EE
  • Service 22DID 15EE
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 13333 ÷ 10922500)
Range
0 to 79.9979 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2025.

Battery › Cells

HV battery cell #01 voltage COROLLA_HVBAT_C01_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #02 voltage COROLLA_HVBAT_C02_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #03 voltage COROLLA_HVBAT_C03_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 32 to 47 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #04 voltage COROLLA_HVBAT_C04_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Example reply from a 2024 Toyota Corolla.

Bits 48 to 63 of the reply, 16 bits.

0xB9BA = 47546 → (47546 × 5 ÷ 65535) = 3.627527 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #05 voltage COROLLA_HVBAT_C05_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Example reply from a 2024 Toyota Corolla.

Bits 64 to 79 of the reply, 16 bits.

0xB99B = 47515 → (47515 × 5 ÷ 65535) = 3.625162 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #06 voltage COROLLA_HVBAT_C06_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Example reply from a 2024 Toyota Corolla.

Bits 80 to 95 of the reply, 16 bits.

0xB9BA = 47546 → (47546 × 5 ÷ 65535) = 3.627527 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #07 voltage COROLLA_HVBAT_C07_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Example reply from a 2024 Toyota Corolla.

Bits 96 to 111 of the reply, 16 bits.

0xB9AB = 47531 → (47531 × 5 ÷ 65535) = 3.626383 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #08 voltage COROLLA_HVBAT_C08_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Example reply from a 2024 Toyota Corolla.

Bits 112 to 127 of the reply, 16 bits.

0xB9BA = 47546 → (47546 × 5 ÷ 65535) = 3.627527 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #09 voltage COROLLA_HVBAT_C09_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Example reply from a 2024 Toyota Corolla.

Bits 128 to 143 of the reply, 16 bits.

0xB9AB = 47531 → (47531 × 5 ÷ 65535) = 3.626383 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #10 voltage COROLLA_HVBAT_C10_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Example reply from a 2024 Toyota Corolla.

Bits 144 to 159 of the reply, 16 bits.

0xB97B = 47483 → (47483 × 5 ÷ 65535) = 3.622721 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #11 voltage COROLLA_HVBAT_C11_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Example reply from a 2024 Toyota Corolla.

Bits 160 to 175 of the reply, 16 bits.

0xB97B = 47483 → (47483 × 5 ÷ 65535) = 3.622721 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #12 voltage COROLLA_HVBAT_C12_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Example reply from a 2024 Toyota Corolla.

Bits 176 to 191 of the reply, 16 bits.

0xB9AB = 47531 → (47531 × 5 ÷ 65535) = 3.626383 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #13 voltage COROLLA_HVBAT_C13_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Example reply from a 2024 Toyota Corolla.

Bits 192 to 207 of the reply, 16 bits.

0xB9BA = 47546 → (47546 × 5 ÷ 65535) = 3.627527 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #14 voltage COROLLA_HVBAT_C14_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Example reply from a 2024 Toyota Corolla.

Bits 208 to 223 of the reply, 16 bits.

0xB99B = 47515 → (47515 × 5 ÷ 65535) = 3.625162 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #15 voltage COROLLA_HVBAT_C15_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Example reply from a 2024 Toyota Corolla.

Bits 224 to 239 of the reply, 16 bits.

0xB9BA = 47546 → (47546 × 5 ÷ 65535) = 3.627527 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #16 voltage COROLLA_HVBAT_C16_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Example reply from a 2024 Toyota Corolla.

Bits 240 to 255 of the reply, 16 bits.

0xB9AB = 47531 → (47531 × 5 ÷ 65535) = 3.626383 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #17 voltage COROLLA_HVBAT_C17_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 256 to 271 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #18 voltage COROLLA_HVBAT_C18_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Example reply from a 2024 Toyota Corolla.

Bits 272 to 287 of the reply, 16 bits.

0xB9BA = 47546 → (47546 × 5 ÷ 65535) = 3.627527 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #19 voltage COROLLA_HVBAT_C19_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 288 to 303 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #20 voltage COROLLA_HVBAT_C20_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Example reply from a 2024 Toyota Corolla.

Bits 304 to 319 of the reply, 16 bits.

0xB9BA = 47546 → (47546 × 5 ÷ 65535) = 3.627527 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #21 voltage COROLLA_HVBAT_C21_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Example reply from a 2024 Toyota Corolla.

Bits 320 to 335 of the reply, 16 bits.

0xB9FA = 47610 → (47610 × 5 ÷ 65535) = 3.63241 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #22 voltage COROLLA_HVBAT_C22_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 336 to 351 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #23 voltage COROLLA_HVBAT_C23_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Example reply from a 2024 Toyota Corolla.

Bits 352 to 367 of the reply, 16 bits.

0xBA0A = 47626 → (47626 × 5 ÷ 65535) = 3.633631 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #24 voltage COROLLA_HVBAT_C24_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Example reply from a 2024 Toyota Corolla.

Bits 368 to 383 of the reply, 16 bits.

0xB9FA = 47610 → (47610 × 5 ÷ 65535) = 3.63241 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #25 voltage COROLLA_HVBAT_C25_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 384 to 399 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #26 voltage COROLLA_HVBAT_C26_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Example reply from a 2024 Toyota Corolla.

Bits 400 to 415 of the reply, 16 bits.

0xB9FA = 47610 → (47610 × 5 ÷ 65535) = 3.63241 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #27 voltage COROLLA_HVBAT_C27_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Example reply from a 2024 Toyota Corolla.

Bits 416 to 431 of the reply, 16 bits.

0xBA1B = 47643 → (47643 × 5 ÷ 65535) = 3.634928 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #28 voltage COROLLA_HVBAT_C28_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Example reply from a 2024 Toyota Corolla.

Bits 432 to 447 of the reply, 16 bits.

0xBA1B = 47643 → (47643 × 5 ÷ 65535) = 3.634928 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #29 voltage COROLLA_HVBAT_C29_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Example reply from a 2024 Toyota Corolla.

Bits 448 to 463 of the reply, 16 bits.

0xBA0A = 47626 → (47626 × 5 ÷ 65535) = 3.633631 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #30 voltage COROLLA_HVBAT_C30_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 464 to 479 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #31 voltage COROLLA_HVBAT_C31_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 480 to 495 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #32 voltage COROLLA_HVBAT_C32_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Example reply from a 2024 Toyota Corolla.

Bits 496 to 511 of the reply, 16 bits.

0xB9BA = 47546 → (47546 × 5 ÷ 65535) = 3.627527 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #33 voltage COROLLA_HVBAT_C33_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 512 to 527 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #34 voltage COROLLA_HVBAT_C34_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Example reply from a 2024 Toyota Corolla.

Bits 528 to 543 of the reply, 16 bits.

0xB9AB = 47531 → (47531 × 5 ÷ 65535) = 3.626383 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #35 voltage COROLLA_HVBAT_C35_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 544 to 559 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #36 voltage COROLLA_HVBAT_C36_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 560 to 575 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #37 voltage COROLLA_HVBAT_C37_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Example reply from a 2024 Toyota Corolla.

Bits 576 to 591 of the reply, 16 bits.

0xB9FA = 47610 → (47610 × 5 ÷ 65535) = 3.63241 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #38 voltage COROLLA_HVBAT_C38_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Example reply from a 2024 Toyota Corolla.

Bits 592 to 607 of the reply, 16 bits.

0xB9AB = 47531 → (47531 × 5 ÷ 65535) = 3.626383 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #39 voltage COROLLA_HVBAT_C39_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Example reply from a 2024 Toyota Corolla.

Bits 608 to 623 of the reply, 16 bits.

0xB9FA = 47610 → (47610 × 5 ÷ 65535) = 3.63241 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #40 voltage COROLLA_HVBAT_C40_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 624 to 639 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #41 voltage COROLLA_HVBAT_C41_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 640 to 655 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #42 voltage COROLLA_HVBAT_C42_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 656 to 671 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #43 voltage COROLLA_HVBAT_C43_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Example reply from a 2024 Toyota Corolla.

Bits 672 to 687 of the reply, 16 bits.

0xB99B = 47515 → (47515 × 5 ÷ 65535) = 3.625162 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #44 voltage COROLLA_HVBAT_C44_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Example reply from a 2024 Toyota Corolla.

Bits 688 to 703 of the reply, 16 bits.

0xB9AB = 47531 → (47531 × 5 ÷ 65535) = 3.626383 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #45 voltage COROLLA_HVBAT_C45_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Example reply from a 2024 Toyota Corolla.

Bits 704 to 719 of the reply, 16 bits.

0xB97B = 47483 → (47483 × 5 ÷ 65535) = 3.622721 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #46 voltage COROLLA_HVBAT_C46_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Example reply from a 2024 Toyota Corolla.

Bits 720 to 735 of the reply, 16 bits.

0xB9BA = 47546 → (47546 × 5 ÷ 65535) = 3.627527 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #47 voltage COROLLA_HVBAT_C47_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Example reply from a 2024 Toyota Corolla.

Bits 736 to 751 of the reply, 16 bits.

0xB9BA = 47546 → (47546 × 5 ÷ 65535) = 3.627527 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #48 voltage COROLLA_HVBAT_C48_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Example reply from a 2024 Toyota Corolla.

Bits 752 to 767 of the reply, 16 bits.

0xB99B = 47515 → (47515 × 5 ÷ 65535) = 3.625162 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #49 voltage COROLLA_HVBAT_C49_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Example reply from a 2024 Toyota Corolla.

Bits 768 to 783 of the reply, 16 bits.

0xB9BA = 47546 → (47546 × 5 ÷ 65535) = 3.627527 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #50 voltage COROLLA_HVBAT_C50_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 784 to 799 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #51 voltage COROLLA_HVBAT_C51_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Example reply from a 2024 Toyota Corolla.

Bits 800 to 815 of the reply, 16 bits.

0xB99B = 47515 → (47515 × 5 ÷ 65535) = 3.625162 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #52 voltage COROLLA_HVBAT_C52_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Example reply from a 2024 Toyota Corolla.

Bits 816 to 831 of the reply, 16 bits.

0xB9BA = 47546 → (47546 × 5 ÷ 65535) = 3.627527 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #53 voltage COROLLA_HVBAT_C53_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 832 to 847 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #54 voltage COROLLA_HVBAT_C54_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Example reply from a 2024 Toyota Corolla.

Bits 848 to 863 of the reply, 16 bits.

0xB9AB = 47531 → (47531 × 5 ÷ 65535) = 3.626383 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #55 voltage COROLLA_HVBAT_C55_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Example reply from a 2024 Toyota Corolla.

Bits 864 to 879 of the reply, 16 bits.

0xB9AB = 47531 → (47531 × 5 ÷ 65535) = 3.626383 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #56 voltage COROLLA_HVBAT_C56_VConfirmed

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Example reply from a 2024 Toyota Corolla.

Bits 880 to 895 of the reply, 16 bits.

0xB9AB = 47531 → (47531 × 5 ÷ 65535) = 3.626383 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #57 voltage COROLLA_HVBAT_C57_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 896 to 911 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #58 voltage COROLLA_HVBAT_C58_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 912 to 927 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #59 voltage COROLLA_HVBAT_C59_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 928 to 943 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #60 voltage COROLLA_HVBAT_C60_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 944 to 959 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #61 voltage COROLLA_HVBAT_C61_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 960 to 975 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #62 voltage COROLLA_HVBAT_C62_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 976 to 991 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #63 voltage COROLLA_HVBAT_C63_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 992 to 1,007 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #64 voltage COROLLA_HVBAT_C64_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 1,008 to 1,023 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #65 voltage COROLLA_HVBAT_C65_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 1,024 to 1,039 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #66 voltage COROLLA_HVBAT_C66_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 1,040 to 1,055 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #67 voltage COROLLA_HVBAT_C67_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 1,056 to 1,071 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #68 voltage COROLLA_HVBAT_C68_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 1,072 to 1,087 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #69 voltage COROLLA_HVBAT_C69_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 1,088 to 1,103 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #70 voltage COROLLA_HVBAT_C70_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 1,104 to 1,119 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #71 voltage COROLLA_HVBAT_C71_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 1,120 to 1,135 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #72 voltage COROLLA_HVBAT_C72_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 1,136 to 1,151 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #73 voltage COROLLA_HVBAT_C73_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 1,152 to 1,167 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #74 voltage COROLLA_HVBAT_C74_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 1,168 to 1,183 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #75 voltage COROLLA_HVBAT_C75_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 1,184 to 1,199 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #76 voltage COROLLA_HVBAT_C76_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 1,200 to 1,215 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #77 voltage COROLLA_HVBAT_C77_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 1,216 to 1,231 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #78 voltage COROLLA_HVBAT_C78_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 1,232 to 1,247 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #79 voltage COROLLA_HVBAT_C79_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 1,248 to 1,263 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #80 voltage COROLLA_HVBAT_C80_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 1,264 to 1,279 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #81 voltage COROLLA_HVBAT_C81_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 1,280 to 1,295 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #82 voltage COROLLA_HVBAT_C82_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 1,296 to 1,311 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #83 voltage COROLLA_HVBAT_C83_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 1,312 to 1,327 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #84 voltage COROLLA_HVBAT_C84_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 1,328 to 1,343 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #85 voltage COROLLA_HVBAT_C85_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 1,344 to 1,359 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #86 voltage COROLLA_HVBAT_C86_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 1,360 to 1,375 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #87 voltage COROLLA_HVBAT_C87_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 1,376 to 1,391 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #88 voltage COROLLA_HVBAT_C88_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 1,392 to 1,407 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #89 voltage COROLLA_HVBAT_C89_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 1,408 to 1,423 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #90 voltage COROLLA_HVBAT_C90_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 1,424 to 1,439 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #91 voltage COROLLA_HVBAT_C91_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 1,440 to 1,455 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #92 voltage COROLLA_HVBAT_C92_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 1,456 to 1,471 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #93 voltage COROLLA_HVBAT_C93_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 1,472 to 1,487 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #94 voltage COROLLA_HVBAT_C94_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 1,488 to 1,503 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #95 voltage COROLLA_HVBAT_C95_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 1,504 to 1,519 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

HV battery cell #96 voltage COROLLA_HVBAT_C96_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing for 1988 to 2023, 2025 to 2026

Bits 1,520 to 1,535 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 1988 to 2008, 2011, 2013, 2015 to 2020, 2026. Not supported for 2009 to 2010, 2012, 2014, 2021 to 2023, 2025.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.