Connectable parameters
The Toyota GR86 has 21 Connectables, parameters that Pelican can monitor automatically.
● Confirmed◆ In testing○ Supported× Not supported
Fuel tank level
Fuel tank level FLISAE J1979Confirmed
Pelican can show this parameter as the fuel tank level.
- Request
01 2F - Service 01
PID 2F - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2013, 2025. Supported for 2022 to 2024.
Speed
Vehicle speed VSSSAE J1979Confirmed
Pelican can show this parameter as the speed.
- Request
01 0D - Service 01
PID 0D - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 km/h
- Unit
- km/h
Confirmed for 2013, 2025. Supported for 2022 to 2024.
Odometer
Odometer ODOSAE J1979Confirmed
Pelican can show this parameter as the odometer.
- Request
01 A6 - Service 01
PID A6 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729.5 km
- Unit
- km
Confirmed for 2025.
Front left tire pressure
Front left tire pressure GR86_TP_2_FL
Pelican can show this parameter as the front left tire pressure.
- Request
21 15 - Service 21
PID 15 - Module
750 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 58 − 0.5)- Range
- 0 to 4
- Unit
- Raw value
In testing for 2012 to 2020, 2023, 2026. Not supported for 2022, 2024 to 2025.
Front left tire pressure GR86_TP_FL
Pelican can show this parameter as the front left tire pressure.
- Request
21 30 - Service 21
PID 30 - Module
750 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 58 − 0.5)- Range
- 0 to 4
- Unit
- Raw value
In testing for 2012 to 2020, 2023, 2026. Not supported for 2022, 2024 to 2025.
Front right tire pressure
Front left tire pressure GR86_TP_2_FR
Pelican can show this parameter as the front right tire pressure.
- Request
21 15 - Service 21
PID 15 - Module
750 - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val ÷ 58 − 0.5)- Range
- 0 to 4
- Unit
- Raw value
In testing for 2012 to 2020, 2023, 2026. Not supported for 2022, 2024 to 2025.
Front left tire pressure GR86_TP_FR
Pelican can show this parameter as the front right tire pressure.
- Request
21 30 - Service 21
PID 30 - Module
750 - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val ÷ 58 − 0.5)- Range
- 0 to 4
- Unit
- Raw value
In testing for 2012 to 2020, 2023, 2026. Not supported for 2022, 2024 to 2025.
Rear left tire pressure
Front left tire pressure GR86_TP_2_RL
Pelican can show this parameter as the rear left tire pressure.
- Request
21 15 - Service 21
PID 15 - Module
750 - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val ÷ 58 − 0.5)- Range
- 0 to 4
- Unit
- Raw value
In testing for 2012 to 2020, 2023, 2026. Not supported for 2022, 2024 to 2025.
Front left tire pressure GR86_TP_RL
Pelican can show this parameter as the rear left tire pressure.
- Request
21 30 - Service 21
PID 30 - Module
750 - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val ÷ 58 − 0.5)- Range
- 0 to 4
- Unit
- Raw value
In testing for 2012 to 2020, 2023, 2026. Not supported for 2022, 2024 to 2025.
Rear right tire pressure
Front left tire pressure GR86_TP_2_RR
Pelican can show this parameter as the rear right tire pressure.
- Request
21 15 - Service 21
PID 15 - Module
750 - Every
5 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val ÷ 58 − 0.5)- Range
- 0 to 4
- Unit
- Raw value
In testing for 2012 to 2020, 2023, 2026. Not supported for 2022, 2024 to 2025.
Front left tire pressure GR86_TP_RR
Pelican can show this parameter as the rear right tire pressure.
- Request
21 30 - Service 21
PID 30 - Module
750 - Every
5 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val ÷ 58 − 0.5)- Range
- 0 to 4
- Unit
- Raw value
In testing for 2012 to 2020, 2023, 2026. Not supported for 2022, 2024 to 2025.
Commanded lambda
Commanded equivalence ratio EQ_RATSAE J1979Confirmed
Fuel systems that utilize conventional oxygen sensor display the inverse of the commanded open loop equivalence ratio (also known as lambda) while the fuel control system is in open loop. Will indicate 1.000 while in closed-loop fuel.
Pelican can show this parameter as the commanded lambda.
- Request
01 44 - Service 01
PID 44 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2 ÷ 65535)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2013. Supported for 2022 to 2025.
Distance since trouble codes were cleared
Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed
Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.
Pelican can show this parameter as the distance since trouble codes were cleared.
- Request
01 31 - Service 01
PID 31 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2013, 2025. Supported for 2022 to 2024.
Engine coolant temperature
Engine coolant temperature ECTSAE J1979Confirmed
Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.
Pelican can show this parameter as the engine coolant temperature.
- Request
01 05 - Service 01
PID 05 - Module
7E0 → 7E8 - Every
500 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2013, 2025. Supported for 2022 to 2024.
Engine load
Calculated engine load LOAD_PCTSAE J1979Confirmed
Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.
Pelican can show this parameter as the engine load.
- Request
01 04 - Service 01
PID 04 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2013, 2025. Supported for 2022 to 2024.
Engine oil temperature
Engine oil temperature EOTSAE J1979Confirmed
Pelican can show this parameter as the engine oil temperature.
- Request
01 5C - Service 01
PID 5C - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 210 °C
- Unit
- °C
Confirmed for 2025. Supported for 2023.
Mass air flow
Air flow rate from mass air flow sensor MAFSAE J1979Confirmed
Pelican can show this parameter as the mass air flow.
- Request
01 10 - Service 01
PID 10 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 g/s
- Unit
- g/s
Confirmed for 2013, 2025. Supported for 2022 to 2024.
O2 lambda
Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed
Pelican can show this parameter as the O2 lambda.
- Request
01 34 - Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32768)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2025. Supported for 2024.
Short term fuel trim
Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed
Correction being used by the closed-loop fuel algorithm.
Pelican can show this parameter as the short term fuel trim.
- Request
01 06 - Service 01
PID 06 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2013, 2025. Supported for 2022 to 2024.
Starter battery voltage
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Request
01 42 - Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65535 V
- Unit
- V
Confirmed for 2013. Supported for 2022 to 2025.
Throttle position
Absolute throttle position TPSAE J1979Confirmed
Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.
Pelican can show this parameter as the throttle position.
- Request
01 11 - Service 01
PID 11 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2025. Supported for 2022 to 2024.