Battery parameters
The Volvo XC90 has 42 battery parameters.
● Confirmed◆ In testing○ Supported× Not supported
Auxiliary battery current XC90_AUXILIARY_BAT
- Request
22 41 12 - Service 22
DID 4112 - Module
D01A → 1F402E80 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 127)- Range
- -127 to 128 A
- Unit
- A
In testing for 2016, 2018 to 2023, 2025 to 2026. Not supported for 2017, 2024.
Auxiliary battery temperature XC90_AUXILIARY_BAT_T
- Request
22 40 D3 - Service 22
DID 40D3 - Module
D01A → 1F402E80 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2016, 2018 to 2023, 2025 to 2026. Not supported for 2017, 2024.
Auxiliary battery voltage XC90_AUXILIARY_BAT_V
Pelican can show this parameter as the starter battery voltage.
- Request
22 41 7E - Service 22
DID 417E - Module
D01A → 1F402E80 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2016, 2018 to 2023, 2025 to 2026. Not supported for 2017, 2024.
Average static low range battery current XC90_AVG_STATIC_LOW_RANGE
- Request
22 40 25 - Service 22
DID 4025 - Module
D01A → 1F402E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val − 511)- Range
- -511 to 65024 mA
- Unit
- mA
In testing for 2016, 2018 to 2023, 2025 to 2026. Not supported for 2017, 2024.
Battery current XC90_BAT_CURRENT
- Request
22 40 90 - Service 22
DID 4090 - Module
D01A → 1F402E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 512)- Range
- -512 to 3583 A
- Unit
- A
In testing for 2016, 2018 to 2023, 2025 to 2026. Not supported for 2017, 2024.
Battery relay XC90_BAT_RELAY
- Request
22 D9 53 - Service 22
DID D953 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2021.
Battery state of charge XC90_BAT_ST_CHG
- Request
22 40 28 - Service 22
DID 4028 - Module
D01A → 1F402E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 %
- Unit
- %
In testing for 2016, 2018 to 2023, 2025 to 2026. Not supported for 2017, 2024.
Battery voltage XC90_BAT_V
Pelican can show this parameter as the starter battery voltage.
- Request
22 40 CD - Service 22
DID 40CD - Module
D01A → 1F402E80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 40 + 5)- Range
- 0 to 1643 V
- Unit
- V
In testing for 2016, 2018 to 2023, 2025 to 2026. Not supported for 2017, 2024.
Boost pressure after turbocharger XC90_BOOST_P_AFTER
- Request
22 03 3E - Service 22
DID 033E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 131 − 0.053435)- Range
- -0.0534 to 500 kPa
- Unit
- kPa
In testing for 2016 to 2021.
Charger cable current XC90_CHARGER_CABLE
- Request
22 EE 8D - Service 22
DID EE8D - Module
D016 → 1EC68E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 410)- Range
- -410 to 6143 A
- Unit
- A
In testing for 2016, 2018 to 2023, 2025 to 2026. Not supported for 2017, 2024.
Charging socket lock XC90_CHG_SOCKET_LOCKED
- Request
22 EE 8C - Service 22
DID EE8C - Module
D016 → 1EC68E80 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | UNLOCKED | Unlocked |
2 | LOCKED | Locked |
In testing for 2016, 2018 to 2023, 2025 to 2026. Not supported for 2017, 2024.
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Request
01 42 - Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65535 V
- Unit
- V
Confirmed for 2023 to 2024. Supported for 2006, 2009 to 2010, 2016 to 2022, 2025 to 2026.
DC charger current XC90_DC_CHARGER_CURRENT
- Request
22 EE 16 - Service 22
DID EE16 - Module
D016 → 1EC68E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 A
- Unit
- A
In testing for 2016, 2018 to 2023, 2025 to 2026. Not supported for 2017, 2024.
DC charger voltage XC90_DC_CHARGER_V
- Request
22 EE 17 - Service 22
DID EE17 - Module
D016 → 1EC68E80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 V
- Unit
- V
In testing for 2016, 2018 to 2023, 2025 to 2026. Not supported for 2017, 2024.
Enhanced Hybrid/EV Vehicle Charging State EHEV_MODESAE J1979Confirmed
- Request
01 9A - Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bits 1 to 2 of the reply, 2 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | CSM | Charge sustaining mode |
1 | CDM | Charge depleting mode |
2 | CIM | Charge increasing mode |
Confirmed for 2023 to 2025. Supported for 2017 to 2018.
High voltage battery current XC90_HVBAT_CURRENT
Pelican can show this parameter as the traction battery current.
- Request
22 48 02 - Service 22
DID 4802 - Module
D016 → 1EC6AE80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 50)- Range
- -655 to 655 A
- Unit
- A
In testing for 2016, 2018 to 2023, 2025 to 2026. Not supported for 2017, 2024.
High voltage battery state of charge XC90_HVBAT_ST_CHG
Pelican can show this parameter as the state of charge.
- Request
22 48 01 - Service 22
DID 4801 - Module
D016 → 1EC6AE80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 500)- Range
- 0 to 131 %
- Unit
- %
In testing for 2016, 2018 to 2023, 2025 to 2026. Not supported for 2017, 2024.
High voltage battery voltage XC90_HVBAT_V
Pelican can show this parameter as the traction battery voltage.
- Request
22 48 03 - Service 22
DID 4803 - Module
D016 → 1EC6AE80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 V
- Unit
- V
In testing for 2016, 2018 to 2023, 2025 to 2026. Not supported for 2017, 2024.
High voltage battery, average temperature XC90_HVBAT_AVG_T
- Request
22 49 1B - Service 22
DID 491B - Module
D016 → 1EC6AE80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100 − 50)- Range
- -50 to 605 °C
- Unit
- °C
In testing for 2016, 2018 to 2023, 2025 to 2026. Not supported for 2017, 2024.
High voltage battery, coolant pump speed, actual XC90_HVBAT_CLT_PMP_SPD_ACT
- Request
22 48 67 - Service 22
DID 4867 - Module
D016 → 1EC6AE80 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 24)- Range
- 0 to 6120 rpm
- Unit
- rpm
In testing for 2016, 2018 to 2023, 2025 to 2026. Not supported for 2017, 2024.
High voltage battery, coolant pump speed, requested XC90_HVBAT_CLT_PMP_SPD
- Request
22 48 66 - Service 22
DID 4866 - Module
D016 → 1EC6AE80 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 24)- Range
- 0 to 6120 rpm
- Unit
- rpm
In testing for 2016, 2018 to 2023, 2025 to 2026. Not supported for 2017, 2024.
High voltage battery, high-voltage coolant heater fuse voltage XC90_HVBAT_HVCH_FUSE_V
- Request
22 48 0A - Service 22
DID 480A - Module
D016 → 1EC6AE80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 V
- Unit
- V
In testing for 2016, 2018 to 2023, 2025 to 2026. Not supported for 2017, 2024.
High voltage battery, IEM fuse voltage XC90_HVBAT_IEM_FUSE_V
- Request
22 48 08 - Service 22
DID 4808 - Module
D016 → 1EC6AE80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 V
- Unit
- V
In testing for 2016, 2018 to 2023, 2025 to 2026. Not supported for 2017, 2024.
High voltage battery, IGM fuse voltage XC90_HVBAT_IGM_FUSE_V
- Request
22 48 09 - Service 22
DID 4809 - Module
D016 → 1EC6AE80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 V
- Unit
- V
In testing for 2016, 2018 to 2023, 2025 to 2026. Not supported for 2017, 2024.
High voltage battery, inlet coolant temperature XC90_HVBAT_INLET_ECT
- Request
22 48 04 - Service 22
DID 4804 - Module
D016 → 1EC6AE80 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2016, 2018 to 2023, 2025 to 2026. Not supported for 2017, 2024.
High voltage battery, max temperature XC90_HVBAT_MAX_T
- Request
22 49 45 - Service 22
DID 4945 - Module
D016 → 1EC6AE80 - Every
5 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 100 − 50)- Range
- -50 to 605 °C
- Unit
- °C
In testing for 2016, 2018 to 2023, 2025 to 2026. Not supported for 2017, 2024.
High voltage battery, OBC fuse voltage XC90_HVBAT_OBC_FUSE_V
- Request
22 48 0B - Service 22
DID 480B - Module
D016 → 1EC6AE80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 V
- Unit
- V
In testing for 2016, 2018 to 2023, 2025 to 2026. Not supported for 2017, 2024.
Hybrid battery pack remaining charge BAT_SOCSAE J1979Confirmed
The percent remaining level of charge for a battery pack used for propulsion, expressed as a percentage of total useable battery energy, commonly referred to as State Of Charge (SOC).
Pelican can show this parameter as the state of charge.
- Request
01 5B - Service 01
PID 5B - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2021, 2023 to 2025. Supported for 2017 to 2018, 2020, 2022.
Hybrid/EV Battery System Current HEV_BATT_ASAE J1979Confirmed
- Request
01 9A - Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bits 32 to 47 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 A
- Unit
- A
Confirmed for 2023 to 2025. Supported for 2017 to 2018.
Hybrid/EV Battery System Voltage HEV_BATT_VSAE J1979Confirmed
- Request
01 9A - Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.98 V
- Unit
- V
Confirmed for 2023 to 2025. Supported for 2017 to 2018.
Hybrid/EV Vehicle Charging State HEV_MODESAE J1979Confirmed
- Request
01 9A - Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bit 0 of the reply.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | CSM | Charge sustaining mode |
1 | CDM | Charge depleting mode |
Confirmed for 2023 to 2025. Supported for 2017 to 2018.
Main charger current XC90_MAIN_CHARGER_CURRENT
- Request
22 EE 15 - Service 22
DID EE15 - Module
D016 → 1EC68E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 A
- Unit
- A
In testing for 2016, 2018 to 2023, 2025 to 2026. Not supported for 2017, 2024.
Main charger voltage XC90_MAIN_CHARGER_V
- Request
22 EE 1C - Service 22
DID EE1C - Module
D016 → 1EC68E80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 2016, 2018 to 2023, 2025 to 2026. Not supported for 2017, 2024.
Module voltage XC90_MODULE_V
- Request
22 D1 11 - Service 22
DID D111 - Module
D016 → 1EC70E80 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2016, 2018 to 2023, 2025 to 2026. Not supported for 2017, 2024.
Start/stop battery relay XC90_START_STOP_BAT_RELAY
- Request
22 EF 51 - Service 22
DID EF51 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2021.
Start/stop secondary battery relay XC90_START_STOP_SECONDARY
- Request
22 EF 52 - Service 22
DID EF52 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2021.
Supercharger clutch, requested position XC90_SUPERCHARGER_CLU_REQ
- Request
22 EE 84 - Service 22
DID EE84 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2021.
Transmission control module supply voltage XC90_MECU_SUP_V
- Request
22 DD 02 - Service 22
DID DD02 - Module
7E1 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 4)- Range
- 0 to 63.75 V
- Unit
- V
In testing for 2016 to 2021.
Battery › Internal
Enhanced Hybrid/EV Vehicle Charging State supported? EHEV_MODE_SUPSAE J1979Confirmed
- Request
01 9A - Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023 to 2025. Supported for 2017 to 2018.
Hybrid/EV Battery Current supported? HEV_BATT_A_SUPSAE J1979Confirmed
- Request
01 9A - Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023 to 2025. Supported for 2017 to 2018.
Hybrid/EV Battery Voltage supported? HEV_BATT_V_SUPSAE J1979Confirmed
- Request
01 9A - Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023 to 2025. Supported for 2017 to 2018.
Hybrid/EV Vehicle Charging State supported? HEV_MODE_SUPSAE J1979Confirmed
- Request
01 9A - Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023 to 2025. Supported for 2017 to 2018.