Volvo XC90

Engine parameters

The Volvo XC90 has 140 engine parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Absolute load value LOAD_ABSConfirmed

  • Request01 43
  • Service 01PID 43
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 25700 %
Unit
%

Confirmed for 2023 to 2025. Supported for 2006, 2010, 2016 to 2022, 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Absolute load value LOAD_ABSSAE J1979Confirmed

  • Request01 43
  • Service 01PID 43
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 25700 %
Unit
%

Confirmed for 2023 to 2025. Supported for 2006, 2010, 2016 to 2022, 2026.

Accelerator pedal position XC90_M3_APP_ECM

  • Request22 F4 49
  • Service 22DID F449
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 2016 to 2021.

Actual engine torque TQ_ACTSAE J1979Confirmed

  • Request01 62
  • Service 01PID 62
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 125)
Range
-125 to 130 %
Unit
%

Confirmed for 2019, 2023 to 2024. Supported for 2020, 2025.

Air conditioning pressure XC90_AC_P

  • Request22 D9 00
  • Service 22DID D900
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 13107 kPa
Unit
kPa

In testing for 2016 to 2021.

Air conditioning relay XC90_AC_RELAY

  • Request22 D9 09
  • Service 22DID D909
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2021.

Air flow rate from mass air flow sensor MAFSAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Request01 10
  • Service 01PID 10
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 g/s
Unit
g/s

Confirmed for 2017, 2019, 2021, 2023 to 2025. Supported for 2006, 2009 to 2010, 2016, 2018, 2020, 2022, 2026.

Air flow/cycle, mg/s XC90_AIR_FLOW_CYCLE_MG_S

  • Request22 D9 16
  • Service 22DID D916
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553
Unit
Number

In testing for 2016 to 2021.

Air mass, desired XC90_AIR_MASS_DES

  • Request22 D9 1F
  • Service 22DID D91F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553
Unit
Raw value

In testing for 2016 to 2021.

Alternator, amps XC90_ALTERNATOR_AMPS

  • Request22 D9 24
  • Service 22DID D924
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 A
Unit
A

In testing for 2016 to 2021.

Average charging time left XC90_AVG_CHG_TIME_LEFT

  • Request22 EE B6
  • Service 22DID EEB6
  • ModuleD016 → 1EC68E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 min
Unit
min

In testing for 2016, 2018 to 2023, 2025 to 2026. Not supported for 2017, 2024.

Barometric pressure BAROSAE J1979Confirmed

Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.

  • Request01 33
  • Service 01PID 33
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2023 to 2024. Supported for 2006, 2009 to 2010, 2016 to 2022, 2025 to 2026.

Boost air pressure after turbocharger XC90_BOOST_AIR_P_AFTER

  • Request22 03 3E
  • Service 22DID 033E
  • ModuleD016 → 1EC60E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 kPa
Unit
kPa

In testing for 2016, 2018 to 2023, 2025 to 2026. Not supported for 2017, 2024.

Boost air temperature XC90_BOOST_AIR_T

  • Request22 03 41
  • Service 22DID 0341
  • ModuleD016 → 1EC60E80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 5 ÷ 8 − 40)
Range
-40 to 119 °C
Unit
°C

In testing for 2016, 2018 to 2023, 2025 to 2026. Not supported for 2017, 2024.

Boost air temperature XC90_BOOST_AIR_T_7E0

  • Request22 03 41
  • Service 22DID 0341
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 5 ÷ 8 − 40)
Range
-40 to 119 °C
Unit
°C

In testing for 2016 to 2021.

Boost pressure XC90_BOOST_P

  • Request22 D9 41
  • Service 22DID D941
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 kPa
Unit
kPa

In testing for 2016 to 2021.

Boost pressure, desired value XC90_BOOST_P_DES

  • Request22 D9 E4
  • Service 22DID D9E4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 kPa
Unit
kPa

In testing for 2016 to 2021.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Request01 04
  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2021, 2023 to 2025. Supported for 2006, 2009 to 2010, 2016 to 2020, 2022, 2026.

Calculated load XC90_CALC_LOAD

Pelican can show this parameter as the engine load.

  • Request22 F4 04
  • Service 22DID F404
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 2016 to 2021.

Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed

  • Request01 3C
  • Service 01PID 3C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2023 to 2024. Supported for 2006, 2010, 2016 to 2022, 2025 to 2026.

Charging state XC90_CHG_ST

  • Request22 EE 1D
  • Service 22DID EE1D
  • ModuleD016 → 1EC68E80
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016, 2018 to 2023, 2025 to 2026. Not supported for 2017, 2024.

Commanded EGR EGR_PCTSAE J1979Confirmed

  • Request01 2C
  • Service 01PID 2C
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2024. Supported for 2009, 2016, 2023, 2026.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Fuel systems that utilize conventional oxygen sensor display the inverse of the commanded open loop equivalence ratio (also known as lambda) while the fuel control system is in open loop. Will indicate 1.000 while in closed-loop fuel.

Pelican can show this parameter as the commanded lambda.

  • Request01 44
  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 2 ÷ 65535)
Range
0 to 1.99
Unit
Number

Confirmed for 2017, 2021, 2023 to 2025. Supported for 2006, 2010, 2016, 2018 to 2020, 2022, 2026.

Commanded evaporative purge EVAP_PCTSAE J1979Confirmed

  • Request01 2E
  • Service 01PID 2E
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2023 to 2024. Supported for 2006, 2010, 2016 to 2022, 2025 to 2026.

Commanded throttle actuator control TAC_PCTSAE J1979Confirmed

  • Request01 4C
  • Service 01PID 4C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2023 to 2024. Supported for 2006, 2009 to 2010, 2016 to 2017, 2019 to 2022, 2025 to 2026.

Control module temperature XC90_CTRL_MODULE_T

  • Request22 D9 B8
  • Service 22DID D9B8
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 5 ÷ 8 − 40)
Range
-40 to 119 °C
Unit
°C

In testing for 2016 to 2021.

Coolant pump relay XC90_CLT_PMP_RELAY

  • Request22 D9 5B
  • Service 22DID D95B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2021.

Cylinder 1 misfire XC90_MIS_1

  • Request22 F6 A2
  • Service 22DID F6A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2021.

Cylinder 1 misfire average XC90_MIS_AVG_1

  • Request22 DA B6
  • Service 22DID DAB6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2021.

Cylinder 2 misfire XC90_MIS_2

  • Request22 F6 A3
  • Service 22DID F6A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2021.

Cylinder 2 misfire average XC90_MIS_AVG_2

  • Request22 DA B6
  • Service 22DID DAB6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2021.

Cylinder 3 misfire XC90_MIS_3

  • Request22 F6 A4
  • Service 22DID F6A4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2021.

Cylinder 3 misfire average XC90_MIS_AVG_3

  • Request22 DA B6
  • Service 22DID DAB6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2021.

Cylinder 4 misfire XC90_MIS_4

  • Request22 F6 A5
  • Service 22DID F6A5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2021.

Cylinder 4 misfire average XC90_MIS_AVG_4

  • Request22 DA B6
  • Service 22DID DAB6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2021.

Cylinder 5 misfire average XC90_MIS_AVG_5

  • Request22 DA B6
  • Service 22DID DAB6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2021.

Cylinder 6 misfire average XC90_MIS_AVG_6

  • Request22 DA B6
  • Service 22DID DAB6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2021.

Cylinder 7 misfire average XC90_MIS_AVG_7

  • Request22 DA B6
  • Service 22DID DAB6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2021.

Cylinder 8 misfire average XC90_MIS_AVG_8

  • Request22 DA B6
  • Service 22DID DAB6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2021.

Diesel particulate filter pressure XC90_DPF_P

  • Request22 DA C8
  • Service 22DID DAC8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2016 to 2021.

Diesel particulate filter soot XC90_DPF_SOOT

  • Request22 D9 F2
  • Service 22DID D9F2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655
Unit
Raw value

In testing for 2016 to 2021.

Diesel particulate filter temperature XC90_DPF_T

  • Request22 D9 F9
  • Service 22DID D9F9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.14)
Range
-273 to 6280 °C
Unit
°C

In testing for 2016 to 2021.

EGR error EGR_ERRSAE J1979Confirmed

  • Request01 2D
  • Service 01PID 2D
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.22 %
Unit
%

Confirmed for 2024. Supported for 2009, 2016, 2023, 2026.

Electric rear axle drive calculated torque XC90_ERAD_CALC_TQ

  • Request22 EF 12
  • Service 22DID EF12
  • ModuleD016 → 1EC6EE80
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 4 − 8188)
Range
-8188 to 253952 N·m
Unit
N·m

In testing for 2016, 2018 to 2023, 2025 to 2026. Not supported for 2017, 2024.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Request01 05
  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2019, 2021, 2023 to 2025. Supported for 2006, 2009 to 2010, 2016 to 2018, 2020, 2022, 2026.

Engine Friction - Percent Torque TQ_FRSAE J1979Confirmed

  • Request01 8E
  • Service 01PID 8E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 125)
Range
-125 to 130 %
Unit
%

Confirmed for 2023 to 2024. Supported for 2019 to 2020.

Engine oil pressure XC90_EOP

  • Request22 EF 4E
  • Service 22DID EF4E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 kPa
Unit
kPa

In testing for 2016 to 2021.

Engine oil temperature XC90_EOT

Pelican can show this parameter as the engine oil temperature.

  • Request22 D9 DC
  • Service 22DID D9DC
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.14)
Range
-273 to 6280 °C
Unit
°C

In testing for 2016 to 2021.

Engine reference torque TQ_REFSAE J1979Confirmed

  • Request01 63
  • Service 01PID 63
  • Module7E0 → 7E8
  • Every86400 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

Confirmed for 2023 to 2024. Supported for 2019 to 2020.

Engine RPM RPMSAE J1979Confirmed

  • Request01 0C
  • Service 01PID 0C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383.75 rpm
Unit
rpm

Confirmed for 2019, 2023 to 2025. Supported for 2006, 2009 to 2010, 2016 to 2018, 2020 to 2022, 2026.

Engine torque XC90_ENG_TQ

  • Request22 DA 89
  • Service 22DID DA89
  • ModuleD016 → 1EC64E80
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 512)
Range
-512 to 6041 N·m
Unit
N·m

In testing for 2016, 2018 to 2023, 2025 to 2026. Not supported for 2017, 2024.

Exhaust gas recirculation bypass valve XC90_EGR_BYPASS_VLV

  • Request22 EE 7F
  • Service 22DID EE7F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2016 to 2021.

Exhaust gas recirculation cooler bypass actuator position XC90_EGR_COOLER_BYPASS

  • Request22 DA D2
  • Service 22DID DAD2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 %
Unit
%

In testing for 2016 to 2021.

Exhaust gas recirculation valve position sensor XC90_EGR_VLV_POS_SENS

  • Request22 DA AD
  • Service 22DID DAAD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 %
Unit
%

In testing for 2016 to 2021.

Exhaust gas recirculation valve, commanded position XC90_EGR_VLV_CMD_POS

  • Request22 DC 01
  • Service 22DID DC01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 %
Unit
%

In testing for 2016 to 2021.

Exhaust gas recirculation valve, commanded position II XC90_EGR_VLV_CMD_POS_II

  • Request22 D9 6D
  • Service 22DID D96D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 %
Unit
%

In testing for 2016 to 2021.

Fan XC90_FAN

  • Request22 DC 02
  • Service 22DID DC02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 %
Unit
%

In testing for 2016 to 2021.

Front oxygen sensor heating XC90_FRONT_OXYGEN_SENS

  • Request22 DA 59
  • Service 22DID DA59
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 ms
Unit
ms

In testing for 2016 to 2021.

Fuel rail pressure (absolute) FRP_ABSSAE J1979Confirmed

Fuel rail pressure at the engine when the reading is referenced to atmosphere (gage pressure).

  • Request01 59
  • Service 01PID 59
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 10)
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2023 to 2024. Supported for 2016 to 2017, 2019 to 2022, 2025 to 2026.

Glow plugs XC90_GLOW_PLUGS

  • Request22 D9 A0
  • Service 22DID D9A0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 %
Unit
%

In testing for 2016 to 2021.

Grill shutter open XC90_GRILL_SHUTTER_OPEN

  • Request22 07 07
  • Service 22DID 0707
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 2016 to 2021.

High voltage system current XC90_HIGH_V_SYSTEM

  • Request22 EF 13
  • Service 22DID EF13
  • ModuleD016 → 1EC6EE80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 2 − 250)
Range
-250 to 260 A
Unit
A

In testing for 2016, 2018 to 2023, 2025 to 2026. Not supported for 2017, 2024.

Ignition angle before top dead center XC90_IGN_ANG_BTDC

  • Request22 F4 0E
  • Service 22DID F40E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2 − 64)
Range
-64 to 63.5
Unit
Number

In testing for 2016 to 2021.

Intake air temperature IATSAE J1979Confirmed

  • Request01 0F
  • Service 01PID 0F
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023 to 2024. Supported for 2006, 2009 to 2010, 2016 to 2022, 2025 to 2026.

Intake air temperature, manifold sensor XC90_TMAP_IAT

  • Request22 D9 AB
  • Service 22DID D9AB
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.14)
Range
-3549 to 3003 °C
Unit
°C

In testing for 2016 to 2021.

Intake manifold absolute pressure MAPSAE J1979Confirmed

  • Request01 0B
  • Service 01PID 0B
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2023 to 2024. Supported for 2006, 2009 to 2010, 2016 to 2022, 2025 to 2026.

Leading A/T XC90_LEADING_T

  • Request22 1E 2F
  • Service 22DID 1E2F
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2016 to 2021.

Load XC90_LOAD

  • Request22 F4 43
  • Service 22DID F443
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 25700 %
Unit
%

In testing for 2016 to 2021.

Long term fuel trim (bank 1) LONGFT1SAE J1979Confirmed

  • Request01 07
  • Service 01PID 07
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.2 %
Unit
%

Confirmed for 2023 to 2024. Supported for 2006, 2010, 2016 to 2022, 2025 to 2026.

Long term secondary O2 sensor fuel trim (bank 1) LGSO2FT1SAE J1979Confirmed

  • Request01 56
  • Service 01PID 56
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.22 %
Unit
%

Confirmed for 2023 to 2024. Supported for 2016 to 2017, 2019 to 2022, 2025 to 2026.

M3 APP, CAN XC90_M3_APP_CAN

  • Request22 F4 4A
  • Service 22DID F44A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 2016 to 2021.

M3 diff.press. XC90_M3_DIFF_PRESS

  • Request22 D9 F3
  • Service 22DID D9F3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2016 to 2021.

M3 DPF soot XC90_M3_DPF_SOOT

  • Request22 D9 F2
  • Service 22DID D9F2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 10000)
Range
0 to 6.55 g
Unit
g

In testing for 2016 to 2021.

M3 EGR DC XC90_M3_EGR_DC

  • Request22 D9 6C
  • Service 22DID D96C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 %
Unit
%

In testing for 2016 to 2021.

M3 IAT, butterfly XC90_M3_IAT_BUTTERFLY

  • Request22 F4 0F
  • Service 22DID F40F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2016 to 2021.

M3 IAT, MAF XC90_M3_IAT_MAF

  • Request22 D9 1C
  • Service 22DID D91C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.53 °C
Unit
°C

In testing for 2016 to 2021.

Misfire catalytic damage total - petrol XC90_MIS_CATALYTIC_DAMAGE

  • Request22 DA 03
  • Service 22DID DA03
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2021.

Module current XC90_MODULE_CURRENT

  • Request22 19 46
  • Service 22DID 1946
  • ModuleD016 → 1EC70E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2016, 2018 to 2023, 2025 to 2026. Not supported for 2017, 2024.

On-board charger module temperature XC90_OBC_T

  • Request22 EE 19
  • Service 22DID EE19
  • ModuleD016 → 1EC68E80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2016, 2018 to 2023, 2025 to 2026. Not supported for 2017, 2024.

Rear oxygen sensor heating XC90_REAR_OXYGEN_SENS

  • Request22 DB 77
  • Service 22DID DB77
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 ms
Unit
ms

In testing for 2016 to 2021.

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Request01 06
  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.2 %
Unit
%

Confirmed for 2021, 2023 to 2025. Supported for 2006, 2010, 2016 to 2020, 2022, 2026.

Slave A/T XC90_SLAVE_T

  • Request22 1E 1B
  • Service 22DID 1E1B
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2016 to 2021.

SLC1 current XC90_SLC1_CURRENT

  • Request22 D9 0C
  • Service 22DID D90C
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2016 to 2021.

SLC2 current XC90_SLC2_CURRENT

  • Request22 D9 0F
  • Service 22DID D90F
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2016 to 2021.

SLC3 current XC90_SLC3_CURRENT

  • Request22 D9 10
  • Service 22DID D910
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2016 to 2021.

Starter relay XC90_STARTER_RELAY

  • Request22 D9 50
  • Service 22DID D950
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2021.

Starter relay 1 XC90_STARTER_RELAY_1

  • Request22 DA 12
  • Service 22DID DA12
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2021.

Starter relay 2 XC90_STARTER_RELAY_2

  • Request22 EE EB
  • Service 22DID EEEB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2021.

System relay XC90_SYSTEM_RELAY

  • Request22 D9 4F
  • Service 22DID D94F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2021.

Throttle absolute position XC90_THROTTLE_ABS_POS

Pelican can show this parameter as the throttle position.

  • Request22 F4 11
  • Service 22DID F411
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 2016 to 2021.

Time since engine start XC90_TIME_SINCE_ENG_START

  • Request22 F4 1F
  • Service 22DID F41F
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

In testing for 2016 to 2021.

Timing advance SPARKADVSAE J1979Confirmed

Ignition timing spark advance for the first cylinder. Measured in degrees before dead center. Minus is degrees before dead center, positive is degrees after.

  • Request01 0E
  • Service 01PID 0E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2 − 64)
Range
-64 to 63.5 °
Unit
°

Confirmed for 2023 to 2024. Supported for 2006, 2010, 2016 to 2022, 2025 to 2026.

Torque converter lock-up solenoid XC90_LOCK_UP_SOLENOID_SLU_7E1

  • Request22 DA 4C
  • Service 22DID DA4C
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2016 to 2021.

Torque converter lock-up solenoid current XC90_LOCK_UP_SOLENOID_SLU_CURRENT

  • Request22 1E 47
  • Service 22DID 1E47
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2016 to 2021.

Torque converter lock-up solenoid current, requested XC90_LOCK_UP_SOLENOID_SLU

  • Request22 1E 41
  • Service 22DID 1E41
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2016 to 2021.

Torque converter lock-up solenoid, requested XC90_LOCK_UP_SOLENOID_SLU_REQ

  • Request22 DA 4B
  • Service 22DID DA4B
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2016 to 2021.

Torque from engine XC90_TQ_ENG

  • Request22 E5 01
  • Service 22DID E501
  • ModuleDA18 → 18
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2002 to 2014.

Transmission fixed lock-up XC90_FIXED_LOCK_UP

  • Request22 1E 24
  • Service 22DID 1E24
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2021.

Transmission kickdown XC90_KICKDOWN

  • Request22 DC E4
  • Service 22DID DCE4
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2021.

Transmission line pressure solenoid current XC90_LINEAR_P_SOLENOID_SLT

  • Request22 1E 40
  • Service 22DID 1E40
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2016 to 2021.

Transmission line pressure solenoid current XC90_LINEAR_P_SOLENOID_SLT_CURRENT

  • Request22 DA 4A
  • Service 22DID DA4A
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2016 to 2021.

Transmission line pressure solenoid current, requested XC90_LINEAR_P_SOLENOID

  • Request22 1E 1E
  • Service 22DID 1E1E
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2016 to 2021.

Transmission line pressure solenoid current, requested XC90_LINEAR_P_SOLENOID_SLT_REQ

  • Request22 DA 49
  • Service 22DID DA49
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2016 to 2021.

Transmission linear pressure solenoid SL1 current XC90_LINEAR_P_SOLENOID_SL1

  • Request22 DA 4E
  • Service 22DID DA4E
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2016 to 2021.

Transmission linear pressure solenoid SL1, requested, current XC90_LINEAR_P_SOLENOID_SL1_REQ

  • Request22 DA 4D
  • Service 22DID DA4D
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2016 to 2021.

Transmission linear pressure solenoid SL2 current XC90_LINEAR_P_SOLENOID_SL2

  • Request22 DA 50
  • Service 22DID DA50
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2016 to 2021.

Transmission linear pressure solenoid SL2, requested, current XC90_LINEAR_P_SOLENOID_SL2_REQ

  • Request22 DA 4F
  • Service 22DID DA4F
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2016 to 2021.

Transmission linear pressure solenoid SL3 current XC90_LINEAR_P_SOLENOID_SL3

  • Request22 DA 52
  • Service 22DID DA52
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2016 to 2021.

Transmission linear pressure solenoid SL3, requested, current XC90_LINEAR_P_SOLENOID_SL3_REQ

  • Request22 DA 51
  • Service 22DID DA51
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2016 to 2021.

Transmission linear pressure solenoid SLB1, requested, current XC90_LINEAR_P_SOLENOID_SLB1_REQ

  • Request22 1E 45
  • Service 22DID 1E45
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2016 to 2021.

Transmission linear pressure solenoid SLC1 current XC90_LINEAR_P_SOLENOID_SLC1

  • Request22 1E 48
  • Service 22DID 1E48
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2016 to 2021.

Transmission linear pressure solenoid SLC1, requested, current XC90_LINEAR_P_SOLENOID_SLC1_REQ

  • Request22 1E 42
  • Service 22DID 1E42
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2016 to 2021.

Transmission linear pressure solenoid SLC2 current XC90_LINEAR_P_SOLENOID_SLC2

  • Request22 1E 49
  • Service 22DID 1E49
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2016 to 2021.

Transmission linear pressure solenoid SLC2, requested, current XC90_LINEAR_P_SOLENOID_SLC2_REQ

  • Request22 1E 43
  • Service 22DID 1E43
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2016 to 2021.

Transmission linear pressure solenoid SLC3 current XC90_LINEAR_P_SOLENOID_SLC3

  • Request22 1E 4A
  • Service 22DID 1E4A
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2016 to 2021.

Transmission linear pressure solenoid SLC3, requested, current XC90_LINEAR_P_SOLENOID_SLC3_REQ

  • Request22 1E 44
  • Service 22DID 1E44
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2016 to 2021.

Transmission lock-up function XC90_LOCK_UP_FUNCTION

  • Request22 DA 3C
  • Service 22DID DA3C
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 3 − 0.333333)
Range
-0.333 to 84.66
Unit
Number

In testing for 2016 to 2021.

Transmission selector XC90_SELECTOR

  • Request22 DC EA
  • Service 22DID DCEA
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127
Unit
Number

In testing for 2016 to 2021.

Transmission solenoid S1 status XC90_SOLENOID_S1_STAT

  • Request22 DD 89
  • Service 22DID DD89
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2021.

Transmission solenoid S2 status XC90_SOLENOID_S2_STAT

  • Request22 DD 8A
  • Service 22DID DD8A
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2021.

Transmission start lock - start approved XC90_START_LOCK_START

  • Request22 DF 08
  • Service 22DID DF08
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 255)
Range
0 to 1
Unit
Number

In testing for 2016 to 2021.

Transmission torque XC90_TQ

  • Request22 DD 8D
  • Service 22DID DD8D
  • Module7E1
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2016 to 2021.

Transmission torque limiting XC90_TQ_LIMITING

  • Request22 DC F0
  • Service 22DID DCF0
  • Module7E1
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 N·m
Unit
N·m

In testing for 2016 to 2021.

Turbo bypass valve opened XC90_TURBO_BYPASS_VLV

  • Request22 D9 EE
  • Service 22DID D9EE
  • ModuleD016 → 1EC60E80
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016, 2018 to 2023, 2025 to 2026. Not supported for 2017, 2024.

Turbo control valve wastegate XC90_TURBO_CTRL_VLV_WASTEGATE

  • Request22 DC 10
  • Service 22DID DC10
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 100 ÷ 8191)
Range
0 to 800 %
Unit
%

In testing for 2016 to 2021.

Turbo control valve, bypass or variable nozzle XC90_TURBO_CTRL_VLV

  • Request22 DC 00
  • Service 22DID DC00
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 100 ÷ 8191)
Range
0 to 800 %
Unit
%

In testing for 2016 to 2021.

Type of fuel currently being used by the vehicle FUEL_TYPSAE J1979Confirmed

  • Request01 51
  • Service 01PID 51
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1GASGasoline/petrol
2METHMethanol
3ETHEthanol
4DSLDiesel
5LPGLiquefied petroleum gas
6CNGCompressed natural gas
7PROPPropane
8ELECBattery/electric
9BI_GASBi-fuel vehicle using gasoline/petrol
10BI_METHBi-fuel vehicle using methanol
11BI_ETHBi-fuel vehicle using ethanol
12BI_LPGBi-fuel vehicle using LPG
13BI_CNGBi-fuel vehicle using CNG
14BI_PROPBi-fuel vehicle using propane
15BI_ELECBi-fuel vehicle using battery
16BI_MIXBi-fuel vehicle using battery and combustion engine for propulsion
17HYB_GASHybrid vehicle using gasoline engine for propulsion
18HYB_ETHHybrid vehicle using gasoline engine on ethanol for propulsion
19HYB_DSLHybrid vehicle using diesel engine for propulsion
20HYB_ELECHybrid vehicle using battery for propulsion
21HYB_MIXHybrid vehicle using battery and combustion engine for propulsion
22HYB_REGHybrid vehicle in regeneration mode
23BI_DSLBi-fuel vehicle using diesel
24BI_NGBi-fuel vehicle using natural gas
25BI_DSLBi-fuel vehicle using diesel
26NGNatural gas
27DSL_CNGDual fuel vehicle using diesel and CNG
28DSL_LNGDual fuel vehicle using diesel and LNG
29FC_H2Fuel cell utilizing hydrogen
30HICE_HHOHydrogen Internal Combustion Engine
31KEROKerosene
32HFOHeavy Fuel Oil

Confirmed for 2023 to 2024. Supported for 2016 to 2017, 2019 to 2022, 2025 to 2026.

Wastegate position XC90_WASTEGATE_POS

  • Request22 DC 80
  • Service 22DID DC80
  • ModuleD016 → 1EC60E80
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 2016, 2018 to 2023, 2025 to 2026. Not supported for 2017, 2024.

Engine › OxygenSensors

02S Bank 1, Sensor 1 present O2S11_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024. Supported for 2006, 2009 to 2010, 2016 to 2023, 2025 to 2026.

02S Bank 1, Sensor 2 present O2S12_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024. Supported for 2006, 2009 to 2010, 2016 to 2023, 2025 to 2026.

02S Bank 1, Sensor 3 present O2S13_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024. Supported for 2006, 2009 to 2010, 2016 to 2023, 2025 to 2026.

02S Bank 1, Sensor 4 present O2S14_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024. Supported for 2006, 2009 to 2010, 2016 to 2023, 2025 to 2026.

02S Bank 2, Sensor 1 present O2S21_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024. Supported for 2006, 2009 to 2010, 2016 to 2023, 2025 to 2026.

02S Bank 2, Sensor 2 present O2S22_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024. Supported for 2006, 2009 to 2010, 2016 to 2023, 2025 to 2026.

02S Bank 2, Sensor 3 present O2S23_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024. Supported for 2006, 2009 to 2010, 2016 to 2023, 2025 to 2026.

02S Bank 2, Sensor 4 present O2S24_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024. Supported for 2006, 2009 to 2010, 2016 to 2023, 2025 to 2026.

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Request01 34
  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32768)
Range
0 to 1.99
Unit
Number

Confirmed for 2017, 2021, 2023 to 2025. Supported for 2010, 2016, 2018 to 2020, 2026.

O2S Output Voltage Bank 1, Sensor 2 O2S12SAE J1979Confirmed

  • Request01 15
  • Service 01PID 15
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 200)
Range
0 to 1.275 V
Unit
V

Confirmed for 2024. Supported for 2006, 2010, 2016 to 2023, 2025 to 2026.

SHRTFT associated with O2S11 SHRTFT11SAE J1979Confirmed

  • Request01 14
  • Service 01PID 14
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 128)
Range
-100 to 99.22 %
Unit
%

Confirmed for 2024. Supported for 2006, 2010, 2016 to 2023, 2025 to 2026.

Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed

  • Request01 34
  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 256 − 128)
Range
-128 to 127.996 mA
Unit
mA

Confirmed for 2017, 2021, 2023 to 2025. Supported for 2010, 2016, 2018 to 2020, 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.