Audi S5

Battery parameters

The Audi S5 has 130 battery parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Battery voltage S5_BAT_V_2A07Confirmed

Pelican can show this parameter as the starter battery voltage.

  • Request22 2A 07
  • Service 22DID 2A07
  • Module710 → 77A
  • Every5 s
  • Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

0x1EDE = 7902 → (7902 ÷ 1000 + 4) = 11.902 V

Formula
(val ÷ 1000 + 4)
Range
4 to 69.535 V
Unit
V

Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

12V battery adapted capacity S5_AUX_BAT_CAP

  • Request22 2A F7
  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val
Range
0 to 100 Ah
Unit
Ah

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

12V battery aging by capacity S5_AUX_BAT_AGE_CAP

  • Request22 2A F7
  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

12V battery aging by power S5_AUX_BAT_AGE_POW

  • Request22 2A F7
  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

12V battery capacity S5_12V_BAT_CAP

  • Request22 2A 06
  • Service 22DID 2A06
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 Ah
Unit
Ah

In testing for 2007 to 2026.

12V battery current S5_AUX_BAT_C

  • Request22 2A F7
  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 16 to 47 of the reply, 32 bits. The value is signed.

Formula
(val ÷ 1000)
Range
-1000000 to 1000000 A
Unit
A

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

12V battery sensor temperature S5_AUX_BAT_T_S

  • Request22 2A F7
  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

12V battery soc S5_AUX_BAT_SOC

  • Request22 2A F7
  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

12V battery temperature S5_AUX_BAT_T

  • Request22 2A F7
  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

12V battery total charge S5_AUX_BAT_CHRG_TOT

  • Request22 2A F7
  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 96 to 127 of the reply, 32 bits.

Formula
(val ÷ 10)
Range
0 to 10000000 Ah
Unit
Ah

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

12V battery total discharge S5_AUX_BAT_DSCH_TOT

  • Request22 2A F7
  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 128 to 159 of the reply, 32 bits.

Formula
(val ÷ 10)
Range
0 to 10000000 Ah
Unit
Ah

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

12V battery voltage S5_AUX_BAT_V

Pelican can show this parameter as the starter battery voltage.

  • Request22 2A F7
  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 4)
Range
0 to 69 V
Unit
V

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Accelerator pedal, sensor 1 voltage S5_ACCEL_PEDAL_SENS_1_V

  • Request22 10 2A
  • Service 22DID 102A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 13107 mV
Unit
mV

In testing for 2007 to 2026.

Accelerator pedal, sensor 2 voltage S5_ACCEL_PEDAL_SENS_2_V

  • Request22 10 2B
  • Service 22DID 102B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 13107 mV
Unit
mV

In testing for 2007 to 2026.

Aux. hydraulic pump voltage S5_AUX_HYDRAULIC_PMP_V

  • Request22 51 A7
  • Service 22DID 51A7
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 V
Unit
V

In testing for 2007 to 2026.

Battery acid stratification S5_BAT_ACID

  • Request22 2A 1D
  • Service 22DID 2A1D
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 10 + 9)
Range
0 to 2559 %
Unit
%

In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.

Battery charge level S5_BAT_SOCConfirmed

  • Request22 2A 0C
  • Service 22DID 2A0C
  • Module710 → 77A
  • Every10 s
  • Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

0x43 = 67 → 67 %

Formula
val
Range
0 to 100 %
Unit
%

Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.

Battery condition for display S5_BAT_COND_DISPLAY

  • Request22 2A 0D
  • Service 22DID 2A0D
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 10)
Range
0 to 2550 %
Unit
%

In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.

Battery current S5_BAT_IConfirmed

  • Request22 2A 09
  • Service 22DID 2A09
  • Module710 → 77A
  • Every1 s
  • Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 31 of the reply, 32 bits. The value is signed.

0x00000001 = 1 → (1 ÷ 1000) = 0.001 A

Formula
(val ÷ 1000)
Range
-2147483.648 to 2147483 A
Unit
A

Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.

Battery current filtered S5_BAT_CURRENT_FILTERED

  • Request22 2A 08
  • Service 22DID 2A08
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
(val ÷ 1000 − 3000)
Range
-3000 to 13777 A
Unit
A

In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.

Battery internal resistance S5_BAT_INT_RConfirmed

  • Request22 2A 0E
  • Service 22DID 2A0E
  • Module710 → 77A
  • Every5 s
  • Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

0x12 = 18 → (18 × 20 ÷ 100) = 3.6

Formula
(val × 20 ÷ 100)
Range
0 to 51
Unit
Raw value

Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.

Battery internal resistance, raw S5_BAT_INTERNAL_RES_RAW

  • Request22 2A 25
  • Service 22DID 2A25
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 5)
Range
0 to 51
Unit
Raw value

In testing for 2007 to 2026.

Battery power reduction active S5_BMS_PWR_REDUCE_ACTConfirmed

  • Request22 1E 0A
  • Service 22DID 1E0A
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2007 to 2022, 2024 to 2026

Example reply from a 2023 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Battery sensor temperature S5_MQB_BAT_SEN_TConfirmed

  • Request22 2A 0A
  • Service 22DID 2A0A
  • Module710 → 77A
  • Every5 s
  • Testing for 2007 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

0x3D = 61 → (61 − 40) = 21 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023.

Battery temperature S5_BAT_TConfirmed

  • Request22 2A 0B
  • Service 22DID 2A0B
  • Module710 → 77A
  • Every5 s
  • Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

0x33 = 51 → (51 − 40) = 11 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.

Battery total charge S5_MQB_BAT_TOT_CHG

  • Request22 2A 61
  • Service 22DID 2A61
  • Module710 → 77A
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 10)
Range
0 to 429496729.5 Ah
Unit
Ah

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Battery total discharge S5_MQB_BAT_TOT_DIS

  • Request22 2A 61
  • Service 22DID 2A61
  • Module710 → 77A
  • Every3600 s
  • Testing

Bits 32 to 63 of the reply, 32 bits.

Formula
(val ÷ 10)
Range
0 to 429496729.5 Ah
Unit
Ah

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Battery voltage S5_BAT_V_2A07Confirmed

Pelican can show this parameter as the starter battery voltage.

  • Request22 2A 07
  • Service 22DID 2A07
  • Module710 → 77A
  • Every5 s
  • Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

0x1EDE = 7902 → (7902 ÷ 1000 + 4) = 11.902 V

Formula
(val ÷ 1000 + 4)
Range
4 to 69.535 V
Unit
V

Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.

Battery voltage S5_BATTERY_V

Pelican can show this parameter as the starter battery voltage.

  • Request22 10 5A
  • Service 22DID 105A
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 20)
Range
-655360 to 655340 mV
Unit
mV

In testing for 2007 to 2026.

Battery voltage at rest S5_BAT_V_AT_RESTConfirmed

  • Request22 2A 10
  • Service 22DID 2A10
  • Module710 → 77A
  • Every5 s
  • Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

0x21 = 33 → (33 ÷ 10 + 9) = 12.3 V

Formula
(val ÷ 10 + 9)
Range
9 to 34.5 V
Unit
V

Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.

Battery voltage variant S5_PQ35_BAT_V_2Confirmed

  • Request22 10 5E
  • Service 22DID 105E
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2007 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → (0 ÷ 50) = 0 V

Formula
(val ÷ 50)
Range
0 to 1310.7 V
Unit
V

Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.

Boost pressure S5_PQ35_CHG_PConfirmed

  • Request22 10 57
  • Service 22DID 1057
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

0x0D44 = 3396 → (3396 ÷ 1000) = 3.396 bar

Formula
(val ÷ 1000)
Range
0 to 65.535 bar
Unit
bar

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2017, 2024.

Bypass valve high pressure turbine inlet, raw voltage S5_BYPASS_VLV_HIGH_P_V

  • Request22 3D 01
  • Service 22DID 3D01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 13107 mV
Unit
mV

In testing for 2007 to 2026.

Cell state of charge max, index S5_BMS_CELL_SOC_MAX_IDXConfirmed

  • Request22 1E 2C
  • Service 22DID 1E2C
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2007 to 2022, 2024 to 2026

Example reply from a 2023 Audi S5.

Bits 8 to 15 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Cell state of charge max, value S5_BMS_CELL_SOC_MAXConfirmed

  • Request22 1E 2C
  • Service 22DID 1E2C
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2007 to 2022, 2024 to 2026

Example reply from a 2023 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

0x32 = 50 → 50 %

Formula
val
Range
0 to 100 %
Unit
%

Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Cell state of charge min, index S5_BMS_CELL_SOC_MIN_IDXConfirmed

  • Request22 1E 2D
  • Service 22DID 1E2D
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2007 to 2022, 2024 to 2026

Example reply from a 2023 Audi S5.

Bits 8 to 15 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Cell state of charge min, value S5_BMS_CELL_SOC_MINConfirmed

  • Request22 1E 2D
  • Service 22DID 1E2D
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2007 to 2022, 2024 to 2026

Example reply from a 2023 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

0x31 = 49 → 49 %

Formula
val
Range
0 to 100 %
Unit
%

Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Cell voltage max, index S5_BMS_CELL_V_MAX_IDXConfirmed

  • Request22 1E 33
  • Service 22DID 1E33
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2007 to 2022, 2024 to 2026

Example reply from a 2023 Audi S5.

Bits 16 to 23 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Cell voltage max, value S5_BMS_CELL_V_MAXConfirmed

  • Request22 1E 33
  • Service 22DID 1E33
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2007 to 2022, 2024 to 2026

Example reply from a 2023 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

0x0E5B = 3675 → (3675 ÷ 10000) = 0.3675 V

Formula
(val ÷ 10000)
Range
0 to 6.5535 V
Unit
V

Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Cell voltage min, index S5_BMS_CELL_V_MIN_IDXConfirmed

  • Request22 1E 34
  • Service 22DID 1E34
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2007 to 2022, 2024 to 2026

Example reply from a 2023 Audi S5.

Bits 16 to 23 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Cell voltage min, value S5_BMS_CELL_V_MINConfirmed

  • Request22 1E 34
  • Service 22DID 1E34
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2007 to 2022, 2024 to 2026

Example reply from a 2023 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

0x0E54 = 3668 → (3668 ÷ 10000) = 0.3668 V

Formula
(val ÷ 10000)
Range
0 to 6.5535 V
Unit
V

Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Cell voltage sum S5_BMS_CELL_V_SUMConfirmed

  • Request22 1E 3B
  • Service 22DID 1E3B
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2007 to 2022, 2024 to 2026

Example reply from a 2023 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

0x01DD = 477 → (477 ÷ 10) = 47.7 V

Formula
(val ÷ 10)
Range
0 to 6553.5 V
Unit
V

Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Charge air cooler inlet, pressure sensor 1 bank 1 raw value S5_CHG_AIR_COOLER_INLET_P_1_1

  • Request22 44 5A
  • Service 22DID 445A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 13107
Unit
Raw value

In testing for 2007 to 2026.

Charge air pressure S5_PQ35_CHG_AIR_PConfirmed

  • Request22 22 11
  • Service 22DID 2211
  • Module714 → 77E
  • Every1 s
  • Testing for 2007 to 2016, 2018 to 2026

Example reply from a 2017 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → (0 × 100 ÷ 255) = 0 %

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2017. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016.

Charge air pressure actuator position digit.value S5_CHG_AIR_P_ACTUATOR_7E0

  • Request22 1B 11
  • Service 22DID 1B11
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2026.

Charge air pressure actuator, acknowledgment S5_CHG_AIR_P_ACTUATOR

  • Request22 20 65
  • Service 22DID 2065
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2007 to 2026.

Charge air pressure, actual value S5_CHG_AIR_P_ACT

  • Request22 1B 0E
  • Service 22DID 1B0E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 5 ÷ 64)
Range
0 to 5119
Unit
Raw value

In testing for 2007 to 2026.

Charge air pressure, specified value S5_CHG_AIR_P_SPEC

  • Request22 FE 47
  • Service 22DID FE47
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 2)
Range
0 to 510 kPa
Unit
kPa

In testing for 2007 to 2026.

Charge air pressure: actual S5_PQ35_CHARGE_AIR_P_ACTUAL

  • Request22 20 2A
  • Service 22DID 202A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.08)
Range
0 to 5242.8
Unit
Raw value

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Charge air pressure: specified S5_PQ35_CHARGE_AIR_P_SPECIFIEDConfirmed

  • Request22 20 29
  • Service 22DID 2029
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

0x0C02 = 3074 → (3074 × 0.08) = 245.92

Formula
(val × 0.08)
Range
0 to 5242.8
Unit
Raw value

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Charge air temp at the turbocharger outlet, calculated S5_MQB_CHARGE_AIR_T_TUBROCHARGER_OUTLET_CALCULATED

  • Request22 17 98
  • Service 22DID 1798
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2007 to 2016, 2018 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 1000 ÷ 10000 − 273.1)
Range
-273.1 to 3003.6 °C
Unit
°C

In testing for 2007 to 2015, 2018 to 2026. Supported for 2017. Not supported for 2016.

Charge limit overcharge protection S5_PQ35_CHG_LIM_OVER

  • Request22 13 56
  • Service 22DID 1356
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Charge pressure actuator, actual position S5_CHG_P_ACTUATOR_ACT

  • Request22 39 A2
  • Service 22DID 39A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.012207)
Range
0 to 100 %
Unit
%

In testing for 2007 to 2026.

Charge pressure actuator, adaptation for lower stop S5_CHG_P_ACTUATOR_ADPT

  • Request22 39 A5
  • Service 22DID 39A5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 5)
Range
-6553.6 to 6553.4 mV
Unit
mV

In testing for 2007 to 2026.

Charge pressure actuator, adaptation for upper stop S5_CHG_P_ACTUATOR_ADPT_HI

  • Request22 39 A6
  • Service 22DID 39A6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 5)
Range
-6553.6 to 6553.4 mV
Unit
mV

In testing for 2007 to 2026.

Charge pressure actuator, maximum sensor voltage S5_CHG_P_ACTUATOR_MAX_V

  • Request22 3D 77
  • Service 22DID 3D77
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327.68 to 327.67 mV
Unit
mV

In testing for 2007 to 2026.

Charge pressure actuator, specified position S5_CHG_P_ACTUATOR_SPEC

  • Request22 39 A3
  • Service 22DID 39A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 %
Unit
%

In testing for 2007 to 2026.

Charge pressure actuator, specified value S5_CHG_P_ACTUATOR_SPEC_7E0

  • Request22 39 A4
  • Service 22DID 39A4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.012207)
Range
0 to 100 %
Unit
%

In testing for 2007 to 2026.

Charge pressure before throttle valve, calculated actual value S5_CHG_P_BEFORE_ACT

  • Request22 43 2B
  • Service 22DID 432B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 4)
Range
-8192 to 8191
Unit
Raw value

In testing for 2007 to 2026.

Charge pressure control adaptation higher than max. threshold S5_CHG_P_CTRL_ADPT_MAX

  • Request22 29 3E
  • Service 22DID 293E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

In testing for 2007 to 2026.

Charge pressure control adaptation lower than min. threshold S5_CHG_P_CTRL_ADPT_LO_MIN

  • Request22 29 3F
  • Service 22DID 293F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

In testing for 2007 to 2026.

Charge pressure control specified value S5_CHG_P_CTRL_SPEC

  • Request22 11 08
  • Service 22DID 1108
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 20 ÷ 13107)
Range
0 to 100 %
Unit
%

In testing for 2007 to 2026.

Charge pressure control valve activation pulse duty factor S5_CHG_P_CTRL_VLV

  • Request22 3E A9
  • Service 22DID 3EA9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327.68 to 100 %
Unit
%

In testing for 2007 to 2026.

Charge pressure control valve position, actual value S5_CHG_P_CTRL_VLV_POS_ACT

  • Request22 3E A7
  • Service 22DID 3EA7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

In testing for 2007 to 2026.

Charge pressure control valve position, target value S5_CHG_P_CTRL_VLV_POS_TGT

  • Request22 3E A6
  • Service 22DID 3EA6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

In testing for 2007 to 2026.

Charge pressure control valve sensor voltage S5_CHG_P_CTRL_VLV_SENS_V

  • Request22 3E A8
  • Service 22DID 3EA8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 15259 ÷ 100000000)
Range
0 to 9.9999 V
Unit
V

In testing for 2007 to 2026.

Charge pressure control valve voltage, position closed S5_CHG_P_CTRL_VLV_V_POS

  • Request22 3E AB
  • Service 22DID 3EAB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 15259 ÷ 100000000)
Range
0 to 9.9999 V
Unit
V

In testing for 2007 to 2026.

Charge pressure control valve voltage, position opened S5_CHG_P_CTRL_VLV_V_POS_OPENED

  • Request22 3E AC
  • Service 22DID 3EAC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 15259 ÷ 100000000)
Range
0 to 9.9999 V
Unit
V

In testing for 2007 to 2026.

Charge pressure regulator, lower threshold adaptation S5_CHG_P_REGULATOR_LO

  • Request22 16 EC
  • Service 22DID 16EC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 5)
Range
-6553.6 to 6553.4 mV
Unit
mV

In testing for 2007 to 2026.

Charge pressure regulator, upper threshold adaptation S5_CHG_P_REGULATOR_HI

  • Request22 16 ED
  • Service 22DID 16ED
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 5)
Range
-6553.6 to 6553.4 mV
Unit
mV

In testing for 2007 to 2026.

Charge pressure sensor, unconditioned voltage S5_CHG_P_SENS_V

  • Request22 29 C7
  • Service 22DID 29C7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2007 to 2026.

Control module voltage S5_VPWRConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Request22 F4 42
  • Service 22DID F442
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2007 to 2015, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

0x279C = 10140 → (10140 ÷ 1000) = 10.14 V

Formula
(val ÷ 1000)
Range
0 to 65 V
Unit
V

Confirmed for 2016 to 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026.

Cylinder charge specified value S5_CYL_CHG_SPEC

  • Request22 43 2F
  • Service 22DID 432F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7
Unit
Raw value

In testing for 2007 to 2026.

Cylinder charge, actual value S5_CYL_CHG_ACT

  • Request22 43 67
  • Service 22DID 4367
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7
Unit
Raw value

In testing for 2007 to 2026.

DC-DC converter, current S5_DCDC_I

  • Request22 2A 53
  • Service 22DID 2A53
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
(val − 511)
Range
-511 to 65024 A
Unit
A

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

DC-DC converter, low voltage S5_DCDC_V_LOW

  • Request22 2A 53
  • Service 22DID 2A53
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 V
Unit
V

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

DC-DC converter, reserved current S5_DCDC_I_RSV

  • Request22 2A 53
  • Service 22DID 2A53
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
(val − 511)
Range
-511 to 65024 A
Unit
A

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

ECall battery charge level S5_ECALL_SOC

  • Request22 08 38
  • Service 22DID 0838
  • Module767 → 7D1
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

ECall battery status S5_ECALL_STATUS

  • Request22 08 38
  • Service 22DID 0838
  • Module767 → 7D1
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueState
1CRITICAL
2NORMAL

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Electric motor battery energy S5_EM_HVBAT_E_INFO

  • Request22 15 D1
  • Service 22DID 15D1
  • Module710 → 77A
  • Every5 s
  • Testing

Bits 40 to 55 of the reply, 16 bits.

Formula
(val × 50 ÷ 1000)
Range
0 to 3276.75 kWh
Unit
kWh

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Generator target voltage S5_MQB_GEN_TRG_VConfirmed

  • Request22 2A 00
  • Service 22DID 2A00
  • Module710 → 77A
  • Every5 s
  • Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → (0 ÷ 10 + 10.6) = 10.6 V

Formula
(val ÷ 10 + 10.6)
Range
10.6 to 36.1 V
Unit
V

Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.

Generator voltage, actual S5_GEN_V_ACT

  • Request22 4F 00
  • Service 22DID 4F00
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 10 + 10.6)
Range
0 to 36.1 V
Unit
V

In testing for 2007 to 2026.

High pressure turbocharger actuator, activation S5_HIGH_P_TURBOCHARGER

  • Request22 11 81
  • Service 22DID 1181
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327 %
Unit
%

In testing for 2007 to 2026.

High voltage battery energy information S5_HIGH_V_EM_HVBAT

  • Request22 15 12
  • Service 22DID 1512
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
(val ÷ 20)
Range
0 to 3276 kWh
Unit
kWh

In testing for 2007 to 2026.

High voltage battery energy information S5_HVBAT_ENERGY

  • Request22 15 12
  • Service 22DID 1512
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 40)
Range
0 to 1638 kWh
Unit
kWh

In testing for 2007 to 2026.

High voltage battery inlet temperature S5_HVBAT_INLET_T

  • Request22 18 9D
  • Service 22DID 189D
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val − 100)
Range
-100 to 155 °C
Unit
°C

In testing for 2007 to 2026.

High voltage battery mode S5_HVBAT_MODE_0_STANDBY_1_2_3_4_5_6_7

  • Request22 74 48
  • Service 22DID 7448
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2026.

High voltage battery outlet temperature S5_HVBAT_OUTLET_T

  • Request22 18 9D
  • Service 22DID 189D
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 100)
Range
-100 to 155 °C
Unit
°C

In testing for 2007 to 2026.

High voltage battery temperature S5_HVBAT_T

  • Request22 2A 0B
  • Service 22DID 2A0B
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 100)
Range
-100 to 155 °C
Unit
°C

In testing for 2007 to 2026.

HV battery coldest sensor S5_HVBAT_T_MIN_NO

  • Request22 1E 0F
  • Service 22DID 1E0F
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

HV battery current S5_HVBAT_CURRENTConfirmed

  • Request22 1E 3D
  • Service 22DID 1E3D
  • Module7E5 → 7ED
  • Every5 s
  • Testing for 2007 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4 − 511)
Range
-200 to 200 A
Unit
A

Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.

HV battery health S5_HVBAT_SOH

  • Request22 51 E0
  • Service 22DID 51E0
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.127 − 1798.574)
Range
-1798.574 to 6524 %
Unit
%

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

HV battery highest cell S5_HVBAT_CELL_V_MAX_NOConfirmed

  • Request22 1E 33
  • Service 22DID 1E33
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2007 to 2022, 2024 to 2026

Example reply from a 2023 Audi S5.

Bits 24 to 31 of the reply, 8 bits.

0x0C = 12 → 12

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.

HV battery lowest cell S5_HVBAT_CELL_V_MIN_NOConfirmed

  • Request22 1E 34
  • Service 22DID 1E34
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2007 to 2022, 2024 to 2026

Example reply from a 2023 Audi S5.

Bits 24 to 31 of the reply, 8 bits.

0x03 = 3 → 3

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.

HV battery state of charge S5_BMS_SOCConfirmed

  • Request22 02 8C
  • Service 22DID 028C
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2007 to 2022, 2024 to 2026

Example reply from a 2023 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

0x31 = 49 → (49 × 100 ÷ 255) = 19.215686 %

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.

HV battery state of charge, hd S5_BMS_SOC_HIRESConfirmed

  • Request22 F4 5B
  • Service 22DID F45B
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2007 to 2022, 2024 to 2026

Example reply from a 2023 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

0x7D = 125 → (125 × 100 ÷ 255) = 49.019608 %

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.

HV battery temperature load S5_HVBAT_T_LOAD

  • Request22 11 65
  • Service 22DID 1165
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 %
Unit
%

In testing for 2007 to 2026.

HV battery temperature, minimum S5_BMS_T_MIN

  • Request22 1E 0F
  • Service 22DID 1E0F
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 100)
Range
-100 to 155 °C
Unit
°C

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

HV battery temperature, minimum, cell number S5_BMS_T_MIN_CELL

  • Request22 1E 0F
  • Service 22DID 1E0F
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

HV battery total ampere hours of charge S5_HVBAT_TOT_AH_CHRG

  • Request22 1E 32
  • Service 22DID 1E32
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 549.31642)
Range
0 to 7818700 Ah
Unit
Ah

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

HV battery total ampere hours of discharge S5_HVBAT_TOT_AH_DCHRG

  • Request22 1E 32
  • Service 22DID 1E32
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 32 to 63 of the reply, 32 bits. The value is signed.

Formula
(val ÷ 549.31642)
Range
-3909350 to 3909350 Ah
Unit
Ah

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

HV battery total kilowatt hours of charge S5_HVBAT_TOT_KWH_CHRG

  • Request22 1E 32
  • Service 22DID 1E32
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 64 to 95 of the reply, 32 bits.

Formula
(val ÷ 8583.07212)
Range
0 to 500300 kWh
Unit
kWh

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

HV battery total kilowatt hours of discharge S5_HVBAT_TOT_KWH_DCHRG

  • Request22 1E 32
  • Service 22DID 1E32
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 96 to 127 of the reply, 32 bits. The value is signed.

Formula
(val ÷ 8583.07212)
Range
-250199 to 250199 kWh
Unit
kWh

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Ignition angle current cylinder S5_PQ35_IGN_ANG_CYLConfirmed

  • Request22 13 7A
  • Service 22DID 137A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2015, 2017 to 2026

Example reply from a 2016 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

0x4D = 77 → (77 × 0.375 − 35.625) = -6.75 N·m

Formula
(val × 0.375 − 35.625)
Range
-35.625 to 60 N·m
Unit
N·m

Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.

Knock sensor voltage, cylinder 1 S5_KNOCK_SENS_V_CYL_1

  • Request22 11 26
  • Service 22DID 1126
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 21333 ÷ 4369000)
Range
0 to 319 V
Unit
V

In testing for 2007 to 2026.

Knock sensor voltage, cylinder 3 S5_KNOCK_SENS_V_CYL_3_7E0

  • Request22 11 27
  • Service 22DID 1127
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 21333 ÷ 4369000)
Range
0 to 319 V
Unit
V

In testing for 2007 to 2026.

Knock sensor voltage:, cylinder 2 S5_KNOCK_SENS_V_CYL_2

  • Request22 13 FC
  • Service 22DID 13FC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000076294)
Range
0 to 4.99 V
Unit
V

In testing for 2007 to 2026.

Knock sensor voltage:, cylinder 3 S5_KNOCK_SENS_V_CYL_3

  • Request22 13 FA
  • Service 22DID 13FA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000076294)
Range
0 to 4.99 V
Unit
V

In testing for 2007 to 2026.

Knock sensor voltage:, cylinder 5 S5_KNOCK_SENS_V_CYL_5

  • Request22 13 FD
  • Service 22DID 13FD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000076294)
Range
0 to 4.99 V
Unit
V

In testing for 2007 to 2026.

Knock sensor voltage:, cylinder 6 S5_KNOCK_SENS_V_CYL_6

  • Request22 13 FB
  • Service 22DID 13FB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000076294)
Range
0 to 4.99 V
Unit
V

In testing for 2007 to 2026.

Knock sensors average voltage bank 1, variant 2 S5_KNOCK_SENSORS_AVG_V_1_2

  • Request22 4E 70
  • Service 22DID 4E70
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2007 to 2026.

Maximum charge current S5_MAX_CHA_CUR_2Confirmed

  • Request22 11 59
  • Service 22DID 1159
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0000 = 0 → (0 ÷ 10) = 0 A

Formula
(val ÷ 10)
Range
-3200 to 3200 A
Unit
A

Confirmed for 2017, 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016, 2023.

Maximum charge voltage S5_BMS_V_CHG_MAXConfirmed

  • Request22 51 71
  • Service 22DID 5171
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2007 to 2022, 2024 to 2026

Example reply from a 2023 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

0x021C = 540 → (540 ÷ 10) = 54 V

Formula
(val ÷ 10)
Range
0 to 6553.5 V
Unit
V

Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Maximum discharge current S5_MAX_DCHA_CUR_2

  • Request22 11 58
  • Service 22DID 1158
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3200 to 3200 A
Unit
A

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Maximum dynamic charge current limit S5_BMS_I_CHG_LIM_DYNConfirmed

  • Request22 1E 1B
  • Service 22DID 1E1B
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2007 to 2022, 2024 to 2026

Example reply from a 2023 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

0x00C8 = 200 → 200 A

Formula
val
Range
0 to 65535 A
Unit
A

Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Maximum dynamic discharge current limit S5_BMS_I_DCHG_LIM_DYNConfirmed

  • Request22 1E 1C
  • Service 22DID 1E1C
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2007 to 2022, 2024 to 2026

Example reply from a 2023 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

0x012C = 300 → 300 A

Formula
val
Range
0 to 65535 A
Unit
A

Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Maximum predicted charge current limit S5_BMS_I_CHG_LIM_PREDConfirmed

  • Request22 1E 1D
  • Service 22DID 1E1D
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2007 to 2022, 2024 to 2026

Example reply from a 2023 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

0x0050 = 80 → 80 A

Formula
val
Range
0 to 65535 A
Unit
A

Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Maximum predicted discharge current limit S5_BMS_I_DCHG_LIM_PREDConfirmed

  • Request22 1E 1E
  • Service 22DID 1E1E
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2007 to 2022, 2024 to 2026

Example reply from a 2023 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

0x0050 = 80 → 80 A

Formula
val
Range
0 to 65535 A
Unit
A

Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Minimum discharge voltage S5_BMS_V_DCHG_MINConfirmed

  • Request22 51 70
  • Service 22DID 5170
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2007 to 2022, 2024 to 2026

Example reply from a 2023 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

0x0186 = 390 → (390 ÷ 10) = 39 V

Formula
(val ÷ 10)
Range
0 to 6553.5 V
Unit
V

Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Minimum dynamic charge voltage S5_BMS_V_CHG_DYN_MINConfirmed

  • Request22 51 74
  • Service 22DID 5174
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2007 to 2022, 2024 to 2026

Example reply from a 2023 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

0x0212 = 530 → (530 ÷ 10) = 53 V

Formula
(val ÷ 10)
Range
0 to 6553.5 V
Unit
V

Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Minimum dynamic discharge voltage S5_BMS_V_DCHG_DYN_MINConfirmed

  • Request22 51 75
  • Service 22DID 5175
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2007 to 2022, 2024 to 2026

Example reply from a 2023 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

0x0191 = 401 → (401 ÷ 10) = 40.1 V

Formula
(val ÷ 10)
Range
0 to 6553.5 V
Unit
V

Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Minimum predicted charge voltage S5_BMS_V_CHG_PRED_MINConfirmed

  • Request22 51 72
  • Service 22DID 5172
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2007 to 2022, 2024 to 2026

Example reply from a 2023 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

0x01FA = 506 → (506 ÷ 10) = 50.6 V

Formula
(val ÷ 10)
Range
0 to 6553.5 V
Unit
V

Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Minimum predicted discharge voltage S5_BMS_V_DCHG_PRED_MINConfirmed

  • Request22 51 73
  • Service 22DID 5173
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2007 to 2022, 2024 to 2026

Example reply from a 2023 Audi S5.

Bits 0 to 15 of the reply, 16 bits.

0x01C1 = 449 → (449 ÷ 10) = 44.9 V

Formula
(val ÷ 10)
Range
0 to 6553.5 V
Unit
V

Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Non-vehicle energy requirement S5_NV_ENERGY_REQUIREMENT

  • Request22 15 D1
  • Service 22DID 15D1
  • Module710 → 77A
  • Every5 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 50 ÷ 1000)
Range
0 to 12.75 kWh
Unit
kWh

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Service regeneration current duration S5_PQ35_SRV_REGEN_DUR

  • Request22 11 64
  • Service 22DID 1164
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val × 0.0001666667)
Range
0 to 715827 min
Unit
min

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Temperature sensor for engine temperature management voltage S5_T_SENS_ENG_T_V

  • Request22 40 E4
  • Service 22DID 40E4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2007 to 2026.

Turbocharger inlet pressure corrected value S5_TURBOCHARGER_INLET_P

  • Request22 11 D4
  • Service 22DID 11D4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 5 ÷ 64)
Range
0 to 5119.9218
Unit
Raw value

In testing for 2007 to 2026.

Usable battery charge S5_USE_BAT_CHGConfirmed

  • Request22 2A 0F
  • Service 22DID 2A0F
  • Module710 → 77A
  • Every5 s
  • Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

0x1E = 30 → 30 Ah

Formula
val
Range
0 to 255 Ah
Unit
Ah

Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.

Battery › Modules

Module 3, temperature 1 S5_HVBAT_MOD3_T1Confirmed

  • Request22 18 23
  • Service 22DID 1823
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2007 to 2022, 2024 to 2026

Example reply from a 2023 Audi S5.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → (0 − 50) = -50 °C

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Module 3, temperature 2 S5_HVBAT_MOD3_T2

  • Request22 18 23
  • Service 22DID 1823
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2007 to 2022, 2024 to 2026

Bits 8 to 15 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Supported for 2023. Not supported for 2016 to 2017, 2024.

Module 3, temperature 3 S5_HVBAT_MOD3_T3

  • Request22 18 23
  • Service 22DID 1823
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2007 to 2022, 2024 to 2026

Bits 16 to 23 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Supported for 2023. Not supported for 2016 to 2017, 2024.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.