Battery parameters
The Audi S5 has 130 battery parameters.
● Confirmed◆ In testing○ Supported× Not supported
12V battery adapted capacity S5_AUX_BAT_CAP
- Request
22 2A F7 - Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 Ah
- Unit
- Ah
In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.
12V battery aging by capacity S5_AUX_BAT_AGE_CAP
- Request
22 2A F7 - Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing
Bits 160 to 167 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.
12V battery aging by power S5_AUX_BAT_AGE_POW
- Request
22 2A F7 - Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.
12V battery capacity S5_12V_BAT_CAP
- Request
22 2A 06 - Service 22
DID 2A06 - Module
710 → 77A - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 Ah
- Unit
- Ah
In testing for 2007 to 2026.
12V battery current S5_AUX_BAT_C
- Request
22 2A F7 - Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing
Bits 16 to 47 of the reply, 32 bits. The value is signed.
- Formula
(val ÷ 1000)- Range
- -1000000 to 1000000 A
- Unit
- A
In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.
12V battery sensor temperature S5_AUX_BAT_T_S
- Request
22 2A F7 - Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.
12V battery soc S5_AUX_BAT_SOC
- Request
22 2A F7 - Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.
12V battery temperature S5_AUX_BAT_T
- Request
22 2A F7 - Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.
12V battery total charge S5_AUX_BAT_CHRG_TOT
- Request
22 2A F7 - Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing
Bits 96 to 127 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 10000000 Ah
- Unit
- Ah
In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.
12V battery total discharge S5_AUX_BAT_DSCH_TOT
- Request
22 2A F7 - Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing
Bits 128 to 159 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 10000000 Ah
- Unit
- Ah
In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.
12V battery voltage S5_AUX_BAT_V
Pelican can show this parameter as the starter battery voltage.
- Request
22 2A F7 - Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 4)- Range
- 0 to 69 V
- Unit
- V
In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.
Accelerator pedal, sensor 1 voltage S5_ACCEL_PEDAL_SENS_1_V
- Request
22 10 2A - Service 22
DID 102A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 13107 mV
- Unit
- mV
In testing for 2007 to 2026.
Accelerator pedal, sensor 2 voltage S5_ACCEL_PEDAL_SENS_2_V
- Request
22 10 2B - Service 22
DID 102B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 13107 mV
- Unit
- mV
In testing for 2007 to 2026.
Aux. hydraulic pump voltage S5_AUX_HYDRAULIC_PMP_V
- Request
22 51 A7 - Service 22
DID 51A7 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2007 to 2026.
Battery acid stratification S5_BAT_ACID
- Request
22 2A 1D - Service 22
DID 2A1D - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10 + 9)- Range
- 0 to 2559 %
- Unit
- %
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Battery charge level S5_BAT_SOCConfirmed
- Request
22 2A 0C - Service 22
DID 2A0C - Module
710 → 77A - Every
10 s - Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 7 of the reply, 8 bits.
0x43 = 67 → 67 %
- Formula
val- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.
Battery condition for display S5_BAT_COND_DISPLAY
- Request
22 2A 0D - Service 22
DID 2A0D - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 %
- Unit
- %
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Battery current S5_BAT_IConfirmed
- Request
22 2A 09 - Service 22
DID 2A09 - Module
710 → 77A - Every
1 s - Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 31 of the reply, 32 bits. The value is signed.
0x00000001 = 1 → (1 ÷ 1000) = 0.001 A
- Formula
(val ÷ 1000)- Range
- -2147483.648 to 2147483 A
- Unit
- A
Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.
Battery current filtered S5_BAT_CURRENT_FILTERED
- Request
22 2A 08 - Service 22
DID 2A08 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
(val ÷ 1000 − 3000)- Range
- -3000 to 13777 A
- Unit
- A
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Battery internal resistance S5_BAT_INT_RConfirmed
- Request
22 2A 0E - Service 22
DID 2A0E - Module
710 → 77A - Every
5 s - Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 7 of the reply, 8 bits.
0x12 = 18 → (18 × 20 ÷ 100) = 3.6
- Formula
(val × 20 ÷ 100)- Range
- 0 to 51
- Unit
- Raw value
Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.
Battery internal resistance, raw S5_BAT_INTERNAL_RES_RAW
- Request
22 2A 25 - Service 22
DID 2A25 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 5)- Range
- 0 to 51
- Unit
- Raw value
In testing for 2007 to 2026.
Battery power reduction active S5_BMS_PWR_REDUCE_ACTConfirmed
- Request
22 1E 0A - Service 22
DID 1E0A - Module
7E5 → 7ED - Every
1 s - Testing for 2007 to 2022, 2024 to 2026
Example reply from a 2023 Audi S5.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.
Battery sensor temperature S5_MQB_BAT_SEN_TConfirmed
- Request
22 2A 0A - Service 22
DID 2A0A - Module
710 → 77A - Every
5 s - Testing for 2007 to 2023, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 7 of the reply, 8 bits.
0x3D = 61 → (61 − 40) = 21 °C
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023.
Battery temperature S5_BAT_TConfirmed
- Request
22 2A 0B - Service 22
DID 2A0B - Module
710 → 77A - Every
5 s - Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 7 of the reply, 8 bits.
0x33 = 51 → (51 − 40) = 11 °C
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.
Battery total charge S5_MQB_BAT_TOT_CHG
- Request
22 2A 61 - Service 22
DID 2A61 - Module
710 → 77A - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729.5 Ah
- Unit
- Ah
In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.
Battery total discharge S5_MQB_BAT_TOT_DIS
- Request
22 2A 61 - Service 22
DID 2A61 - Module
710 → 77A - Every
3600 s - Testing
Bits 32 to 63 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729.5 Ah
- Unit
- Ah
In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.
Battery voltage S5_BAT_V_2A07Confirmed
Pelican can show this parameter as the starter battery voltage.
- Request
22 2A 07 - Service 22
DID 2A07 - Module
710 → 77A - Every
5 s - Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 15 of the reply, 16 bits.
0x1EDE = 7902 → (7902 ÷ 1000 + 4) = 11.902 V
- Formula
(val ÷ 1000 + 4)- Range
- 4 to 69.535 V
- Unit
- V
Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.
Battery voltage S5_BATTERY_V
Pelican can show this parameter as the starter battery voltage.
- Request
22 10 5A - Service 22
DID 105A - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 20)- Range
- -655360 to 655340 mV
- Unit
- mV
In testing for 2007 to 2026.
Battery voltage at rest S5_BAT_V_AT_RESTConfirmed
- Request
22 2A 10 - Service 22
DID 2A10 - Module
710 → 77A - Every
5 s - Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 7 of the reply, 8 bits.
0x21 = 33 → (33 ÷ 10 + 9) = 12.3 V
- Formula
(val ÷ 10 + 9)- Range
- 9 to 34.5 V
- Unit
- V
Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.
Battery voltage variant S5_PQ35_BAT_V_2Confirmed
- Request
22 10 5E - Service 22
DID 105E - Module
7E0 → 7E8 - Every
5 s - Testing for 2007 to 2023, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → (0 ÷ 50) = 0 V
- Formula
(val ÷ 50)- Range
- 0 to 1310.7 V
- Unit
- V
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Boost pressure S5_PQ35_CHG_PConfirmed
- Request
22 10 57 - Service 22
DID 1057 - Module
7E0 → 7E8 - Every
1 s - Testing for 2007 to 2015, 2017 to 2026
Example reply from a 2016 Audi S5.
Bits 0 to 15 of the reply, 16 bits.
0x0D44 = 3396 → (3396 ÷ 1000) = 3.396 bar
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 bar
- Unit
- bar
Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2017, 2024.
Bypass valve high pressure turbine inlet, raw voltage S5_BYPASS_VLV_HIGH_P_V
- Request
22 3D 01 - Service 22
DID 3D01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 13107 mV
- Unit
- mV
In testing for 2007 to 2026.
Cell state of charge max, index S5_BMS_CELL_SOC_MAX_IDXConfirmed
- Request
22 1E 2C - Service 22
DID 1E2C - Module
7E5 → 7ED - Every
1 s - Testing for 2007 to 2022, 2024 to 2026
Example reply from a 2023 Audi S5.
Bits 8 to 15 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.
Cell state of charge max, value S5_BMS_CELL_SOC_MAXConfirmed
- Request
22 1E 2C - Service 22
DID 1E2C - Module
7E5 → 7ED - Every
1 s - Testing for 2007 to 2022, 2024 to 2026
Example reply from a 2023 Audi S5.
Bits 0 to 7 of the reply, 8 bits.
0x32 = 50 → 50 %
- Formula
val- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.
Cell state of charge min, index S5_BMS_CELL_SOC_MIN_IDXConfirmed
- Request
22 1E 2D - Service 22
DID 1E2D - Module
7E5 → 7ED - Every
1 s - Testing for 2007 to 2022, 2024 to 2026
Example reply from a 2023 Audi S5.
Bits 8 to 15 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.
Cell state of charge min, value S5_BMS_CELL_SOC_MINConfirmed
- Request
22 1E 2D - Service 22
DID 1E2D - Module
7E5 → 7ED - Every
1 s - Testing for 2007 to 2022, 2024 to 2026
Example reply from a 2023 Audi S5.
Bits 0 to 7 of the reply, 8 bits.
0x31 = 49 → 49 %
- Formula
val- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.
Cell voltage max, index S5_BMS_CELL_V_MAX_IDXConfirmed
- Request
22 1E 33 - Service 22
DID 1E33 - Module
7E5 → 7ED - Every
1 s - Testing for 2007 to 2022, 2024 to 2026
Example reply from a 2023 Audi S5.
Bits 16 to 23 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.
Cell voltage max, value S5_BMS_CELL_V_MAXConfirmed
- Request
22 1E 33 - Service 22
DID 1E33 - Module
7E5 → 7ED - Every
1 s - Testing for 2007 to 2022, 2024 to 2026
Example reply from a 2023 Audi S5.
Bits 0 to 15 of the reply, 16 bits.
0x0E5B = 3675 → (3675 ÷ 10000) = 0.3675 V
- Formula
(val ÷ 10000)- Range
- 0 to 6.5535 V
- Unit
- V
Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.
Cell voltage min, index S5_BMS_CELL_V_MIN_IDXConfirmed
- Request
22 1E 34 - Service 22
DID 1E34 - Module
7E5 → 7ED - Every
1 s - Testing for 2007 to 2022, 2024 to 2026
Example reply from a 2023 Audi S5.
Bits 16 to 23 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.
Cell voltage min, value S5_BMS_CELL_V_MINConfirmed
- Request
22 1E 34 - Service 22
DID 1E34 - Module
7E5 → 7ED - Every
1 s - Testing for 2007 to 2022, 2024 to 2026
Example reply from a 2023 Audi S5.
Bits 0 to 15 of the reply, 16 bits.
0x0E54 = 3668 → (3668 ÷ 10000) = 0.3668 V
- Formula
(val ÷ 10000)- Range
- 0 to 6.5535 V
- Unit
- V
Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.
Cell voltage sum S5_BMS_CELL_V_SUMConfirmed
- Request
22 1E 3B - Service 22
DID 1E3B - Module
7E5 → 7ED - Every
1 s - Testing for 2007 to 2022, 2024 to 2026
Example reply from a 2023 Audi S5.
Bits 0 to 15 of the reply, 16 bits.
0x01DD = 477 → (477 ÷ 10) = 47.7 V
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.
Charge air cooler inlet, pressure sensor 1 bank 1 raw value S5_CHG_AIR_COOLER_INLET_P_1_1
- Request
22 44 5A - Service 22
DID 445A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 13107
- Unit
- Raw value
In testing for 2007 to 2026.
Charge air pressure S5_PQ35_CHG_AIR_PConfirmed
- Request
22 22 11 - Service 22
DID 2211 - Module
714 → 77E - Every
1 s - Testing for 2007 to 2016, 2018 to 2026
Example reply from a 2017 Audi S5.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → (0 × 100 ÷ 255) = 0 %
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2017. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016.
Charge air pressure actuator position digit.value S5_CHG_AIR_P_ACTUATOR_7E0
- Request
22 1B 11 - Service 22
DID 1B11 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Charge air pressure actuator, acknowledgment S5_CHG_AIR_P_ACTUATOR
- Request
22 20 65 - Service 22
DID 2065 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2007 to 2026.
Charge air pressure, actual value S5_CHG_AIR_P_ACT
- Request
22 1B 0E - Service 22
DID 1B0E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 5 ÷ 64)- Range
- 0 to 5119
- Unit
- Raw value
In testing for 2007 to 2026.
Charge air pressure, specified value S5_CHG_AIR_P_SPEC
- Request
22 FE 47 - Service 22
DID FE47 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 2)- Range
- 0 to 510 kPa
- Unit
- kPa
In testing for 2007 to 2026.
Charge air pressure: actual S5_PQ35_CHARGE_AIR_P_ACTUAL
- Request
22 20 2A - Service 22
DID 202A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.08)- Range
- 0 to 5242.8
- Unit
- Raw value
In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.
Charge air pressure: specified S5_PQ35_CHARGE_AIR_P_SPECIFIEDConfirmed
- Request
22 20 29 - Service 22
DID 2029 - Module
7E0 → 7E8 - Every
1 s - Testing for 2007 to 2015, 2017 to 2026
Example reply from a 2016 Audi S5.
Bits 0 to 15 of the reply, 16 bits.
0x0C02 = 3074 → (3074 × 0.08) = 245.92
- Formula
(val × 0.08)- Range
- 0 to 5242.8
- Unit
- Raw value
Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.
Charge air temp at the turbocharger outlet, calculated S5_MQB_CHARGE_AIR_T_TUBROCHARGER_OUTLET_CALCULATED
- Request
22 17 98 - Service 22
DID 1798 - Module
7E0 → 7E8 - Every
5 s - Testing for 2007 to 2016, 2018 to 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 1000 ÷ 10000 − 273.1)- Range
- -273.1 to 3003.6 °C
- Unit
- °C
In testing for 2007 to 2015, 2018 to 2026. Supported for 2017. Not supported for 2016.
Charge limit overcharge protection S5_PQ35_CHG_LIM_OVER
- Request
22 13 56 - Service 22
DID 1356 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67
- Unit
- Raw value
In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016 to 2017, 2024.
Charge pressure actuator, actual position S5_CHG_P_ACTUATOR_ACT
- Request
22 39 A2 - Service 22
DID 39A2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.012207)- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Charge pressure actuator, adaptation for lower stop S5_CHG_P_ACTUATOR_ADPT
- Request
22 39 A5 - Service 22
DID 39A5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 5)- Range
- -6553.6 to 6553.4 mV
- Unit
- mV
In testing for 2007 to 2026.
Charge pressure actuator, adaptation for upper stop S5_CHG_P_ACTUATOR_ADPT_HI
- Request
22 39 A6 - Service 22
DID 39A6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 5)- Range
- -6553.6 to 6553.4 mV
- Unit
- mV
In testing for 2007 to 2026.
Charge pressure actuator, maximum sensor voltage S5_CHG_P_ACTUATOR_MAX_V
- Request
22 3D 77 - Service 22
DID 3D77 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 mV
- Unit
- mV
In testing for 2007 to 2026.
Charge pressure actuator, specified position S5_CHG_P_ACTUATOR_SPEC
- Request
22 39 A3 - Service 22
DID 39A3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 %
- Unit
- %
In testing for 2007 to 2026.
Charge pressure actuator, specified value S5_CHG_P_ACTUATOR_SPEC_7E0
- Request
22 39 A4 - Service 22
DID 39A4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.012207)- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Charge pressure before throttle valve, calculated actual value S5_CHG_P_BEFORE_ACT
- Request
22 43 2B - Service 22
DID 432B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 4)- Range
- -8192 to 8191
- Unit
- Raw value
In testing for 2007 to 2026.
Charge pressure control adaptation higher than max. threshold S5_CHG_P_CTRL_ADPT_MAX
- Request
22 29 3E - Service 22
DID 293E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Charge pressure control adaptation lower than min. threshold S5_CHG_P_CTRL_ADPT_LO_MIN
- Request
22 29 3F - Service 22
DID 293F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Charge pressure control specified value S5_CHG_P_CTRL_SPEC
- Request
22 11 08 - Service 22
DID 1108 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 20 ÷ 13107)- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Charge pressure control valve activation pulse duty factor S5_CHG_P_CTRL_VLV
- Request
22 3E A9 - Service 22
DID 3EA9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Charge pressure control valve position, actual value S5_CHG_P_CTRL_VLV_POS_ACT
- Request
22 3E A7 - Service 22
DID 3EA7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Charge pressure control valve position, target value S5_CHG_P_CTRL_VLV_POS_TGT
- Request
22 3E A6 - Service 22
DID 3EA6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Charge pressure control valve sensor voltage S5_CHG_P_CTRL_VLV_SENS_V
- Request
22 3E A8 - Service 22
DID 3EA8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 15259 ÷ 100000000)- Range
- 0 to 9.9999 V
- Unit
- V
In testing for 2007 to 2026.
Charge pressure control valve voltage, position closed S5_CHG_P_CTRL_VLV_V_POS
- Request
22 3E AB - Service 22
DID 3EAB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 15259 ÷ 100000000)- Range
- 0 to 9.9999 V
- Unit
- V
In testing for 2007 to 2026.
Charge pressure control valve voltage, position opened S5_CHG_P_CTRL_VLV_V_POS_OPENED
- Request
22 3E AC - Service 22
DID 3EAC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 15259 ÷ 100000000)- Range
- 0 to 9.9999 V
- Unit
- V
In testing for 2007 to 2026.
Charge pressure regulator, lower threshold adaptation S5_CHG_P_REGULATOR_LO
- Request
22 16 EC - Service 22
DID 16EC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 5)- Range
- -6553.6 to 6553.4 mV
- Unit
- mV
In testing for 2007 to 2026.
Charge pressure regulator, upper threshold adaptation S5_CHG_P_REGULATOR_HI
- Request
22 16 ED - Service 22
DID 16ED - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 5)- Range
- -6553.6 to 6553.4 mV
- Unit
- mV
In testing for 2007 to 2026.
Charge pressure sensor, unconditioned voltage S5_CHG_P_SENS_V
- Request
22 29 C7 - Service 22
DID 29C7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2007 to 2026.
Control module voltage S5_VPWRConfirmed
Pelican can show this parameter as the starter battery voltage.
- Request
22 F4 42 - Service 22
DID F442 - Module
7E0 → 7E8 - Every
5 s - Testing for 2007 to 2015, 2018 to 2022, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 15 of the reply, 16 bits.
0x279C = 10140 → (10140 ÷ 1000) = 10.14 V
- Formula
(val ÷ 1000)- Range
- 0 to 65 V
- Unit
- V
Confirmed for 2016 to 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026.
Cylinder charge specified value S5_CYL_CHG_SPEC
- Request
22 43 2F - Service 22
DID 432F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7
- Unit
- Raw value
In testing for 2007 to 2026.
Cylinder charge, actual value S5_CYL_CHG_ACT
- Request
22 43 67 - Service 22
DID 4367 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7
- Unit
- Raw value
In testing for 2007 to 2026.
DC-DC converter, current S5_DCDC_I
- Request
22 2A 53 - Service 22
DID 2A53 - Module
710 → 77A - Every
1 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val − 511)- Range
- -511 to 65024 A
- Unit
- A
In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.
DC-DC converter, low voltage S5_DCDC_V_LOW
- Request
22 2A 53 - Service 22
DID 2A53 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.
DC-DC converter, reserved current S5_DCDC_I_RSV
- Request
22 2A 53 - Service 22
DID 2A53 - Module
710 → 77A - Every
1 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
(val − 511)- Range
- -511 to 65024 A
- Unit
- A
In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.
ECall battery charge level S5_ECALL_SOC
- Request
22 08 38 - Service 22
DID 0838 - Module
767 → 7D1 - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.
ECall battery status S5_ECALL_STATUS
- Request
22 08 38 - Service 22
DID 0838 - Module
767 → 7D1 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State |
|---|---|
1 | CRITICAL |
2 | NORMAL |
In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.
Electric motor battery energy S5_EM_HVBAT_E_INFO
- Request
22 15 D1 - Service 22
DID 15D1 - Module
710 → 77A - Every
5 s - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
(val × 50 ÷ 1000)- Range
- 0 to 3276.75 kWh
- Unit
- kWh
In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.
Generator target voltage S5_MQB_GEN_TRG_VConfirmed
- Request
22 2A 00 - Service 22
DID 2A00 - Module
710 → 77A - Every
5 s - Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → (0 ÷ 10 + 10.6) = 10.6 V
- Formula
(val ÷ 10 + 10.6)- Range
- 10.6 to 36.1 V
- Unit
- V
Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.
Generator voltage, actual S5_GEN_V_ACT
- Request
22 4F 00 - Service 22
DID 4F00 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10 + 10.6)- Range
- 0 to 36.1 V
- Unit
- V
In testing for 2007 to 2026.
High pressure turbocharger actuator, activation S5_HIGH_P_TURBOCHARGER
- Request
22 11 81 - Service 22
DID 1181 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327 %
- Unit
- %
In testing for 2007 to 2026.
High voltage battery energy information S5_HIGH_V_EM_HVBAT
- Request
22 15 12 - Service 22
DID 1512 - Module
710 → 77A - Every
1 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
(val ÷ 20)- Range
- 0 to 3276 kWh
- Unit
- kWh
In testing for 2007 to 2026.
High voltage battery energy information S5_HVBAT_ENERGY
- Request
22 15 12 - Service 22
DID 1512 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 40)- Range
- 0 to 1638 kWh
- Unit
- kWh
In testing for 2007 to 2026.
High voltage battery inlet temperature S5_HVBAT_INLET_T
- Request
22 18 9D - Service 22
DID 189D - Module
7E5 → 7ED - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 100)- Range
- -100 to 155 °C
- Unit
- °C
In testing for 2007 to 2026.
High voltage battery mode S5_HVBAT_MODE_0_STANDBY_1_2_3_4_5_6_7
- Request
22 74 48 - Service 22
DID 7448 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2026.
High voltage battery outlet temperature S5_HVBAT_OUTLET_T
- Request
22 18 9D - Service 22
DID 189D - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 100)- Range
- -100 to 155 °C
- Unit
- °C
In testing for 2007 to 2026.
High voltage battery temperature S5_HVBAT_T
- Request
22 2A 0B - Service 22
DID 2A0B - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 100)- Range
- -100 to 155 °C
- Unit
- °C
In testing for 2007 to 2026.
HV battery coldest sensor S5_HVBAT_T_MIN_NO
- Request
22 1E 0F - Service 22
DID 1E0F - Module
7E5 → 7ED - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.
HV battery current S5_HVBAT_CURRENTConfirmed
- Request
22 1E 3D - Service 22
DID 1E3D - Module
7E5 → 7ED - Every
5 s - Testing for 2007 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4 − 511)- Range
- -200 to 200 A
- Unit
- A
Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.
HV battery health S5_HVBAT_SOH
- Request
22 51 E0 - Service 22
DID 51E0 - Module
7E5 → 7ED - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.127 − 1798.574)- Range
- -1798.574 to 6524 %
- Unit
- %
In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.
HV battery highest cell S5_HVBAT_CELL_V_MAX_NOConfirmed
- Request
22 1E 33 - Service 22
DID 1E33 - Module
7E5 → 7ED - Every
1 s - Testing for 2007 to 2022, 2024 to 2026
Example reply from a 2023 Audi S5.
Bits 24 to 31 of the reply, 8 bits.
0x0C = 12 → 12
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.
HV battery lowest cell S5_HVBAT_CELL_V_MIN_NOConfirmed
- Request
22 1E 34 - Service 22
DID 1E34 - Module
7E5 → 7ED - Every
1 s - Testing for 2007 to 2022, 2024 to 2026
Example reply from a 2023 Audi S5.
Bits 24 to 31 of the reply, 8 bits.
0x03 = 3 → 3
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.
HV battery state of charge S5_BMS_SOCConfirmed
- Request
22 02 8C - Service 22
DID 028C - Module
7E5 → 7ED - Every
1 s - Testing for 2007 to 2022, 2024 to 2026
Example reply from a 2023 Audi S5.
Bits 0 to 7 of the reply, 8 bits.
0x31 = 49 → (49 × 100 ÷ 255) = 19.215686 %
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.
HV battery state of charge, hd S5_BMS_SOC_HIRESConfirmed
- Request
22 F4 5B - Service 22
DID F45B - Module
7E5 → 7ED - Every
1 s - Testing for 2007 to 2022, 2024 to 2026
Example reply from a 2023 Audi S5.
Bits 0 to 7 of the reply, 8 bits.
0x7D = 125 → (125 × 100 ÷ 255) = 49.019608 %
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.
HV battery temperature load S5_HVBAT_T_LOAD
- Request
22 11 65 - Service 22
DID 1165 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 %
- Unit
- %
In testing for 2007 to 2026.
HV battery temperature, minimum S5_BMS_T_MIN
- Request
22 1E 0F - Service 22
DID 1E0F - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 100)- Range
- -100 to 155 °C
- Unit
- °C
In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.
HV battery temperature, minimum, cell number S5_BMS_T_MIN_CELL
- Request
22 1E 0F - Service 22
DID 1E0F - Module
7E5 → 7ED - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.
HV battery total ampere hours of charge S5_HVBAT_TOT_AH_CHRG
- Request
22 1E 32 - Service 22
DID 1E32 - Module
7E5 → 7ED - Every
5 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 549.31642)- Range
- 0 to 7818700 Ah
- Unit
- Ah
In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.
HV battery total ampere hours of discharge S5_HVBAT_TOT_AH_DCHRG
- Request
22 1E 32 - Service 22
DID 1E32 - Module
7E5 → 7ED - Every
5 s - Testing
Bits 32 to 63 of the reply, 32 bits. The value is signed.
- Formula
(val ÷ 549.31642)- Range
- -3909350 to 3909350 Ah
- Unit
- Ah
In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.
HV battery total kilowatt hours of charge S5_HVBAT_TOT_KWH_CHRG
- Request
22 1E 32 - Service 22
DID 1E32 - Module
7E5 → 7ED - Every
5 s - Testing
Bits 64 to 95 of the reply, 32 bits.
- Formula
(val ÷ 8583.07212)- Range
- 0 to 500300 kWh
- Unit
- kWh
In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.
HV battery total kilowatt hours of discharge S5_HVBAT_TOT_KWH_DCHRG
- Request
22 1E 32 - Service 22
DID 1E32 - Module
7E5 → 7ED - Every
5 s - Testing
Bits 96 to 127 of the reply, 32 bits. The value is signed.
- Formula
(val ÷ 8583.07212)- Range
- -250199 to 250199 kWh
- Unit
- kWh
In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.
Ignition angle current cylinder S5_PQ35_IGN_ANG_CYLConfirmed
- Request
22 13 7A - Service 22
DID 137A - Module
7E0 → 7E8 - Every
1 s - Testing for 2007 to 2015, 2017 to 2026
Example reply from a 2016 Audi S5.
Bits 0 to 7 of the reply, 8 bits.
0x4D = 77 → (77 × 0.375 − 35.625) = -6.75 N·m
- Formula
(val × 0.375 − 35.625)- Range
- -35.625 to 60 N·m
- Unit
- N·m
Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.
Knock sensor voltage, cylinder 1 S5_KNOCK_SENS_V_CYL_1
- Request
22 11 26 - Service 22
DID 1126 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 21333 ÷ 4369000)- Range
- 0 to 319 V
- Unit
- V
In testing for 2007 to 2026.
Knock sensor voltage, cylinder 3 S5_KNOCK_SENS_V_CYL_3_7E0
- Request
22 11 27 - Service 22
DID 1127 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 21333 ÷ 4369000)- Range
- 0 to 319 V
- Unit
- V
In testing for 2007 to 2026.
Knock sensor voltage:, cylinder 2 S5_KNOCK_SENS_V_CYL_2
- Request
22 13 FC - Service 22
DID 13FC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000076294)- Range
- 0 to 4.99 V
- Unit
- V
In testing for 2007 to 2026.
Knock sensor voltage:, cylinder 3 S5_KNOCK_SENS_V_CYL_3
- Request
22 13 FA - Service 22
DID 13FA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000076294)- Range
- 0 to 4.99 V
- Unit
- V
In testing for 2007 to 2026.
Knock sensor voltage:, cylinder 5 S5_KNOCK_SENS_V_CYL_5
- Request
22 13 FD - Service 22
DID 13FD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000076294)- Range
- 0 to 4.99 V
- Unit
- V
In testing for 2007 to 2026.
Knock sensor voltage:, cylinder 6 S5_KNOCK_SENS_V_CYL_6
- Request
22 13 FB - Service 22
DID 13FB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000076294)- Range
- 0 to 4.99 V
- Unit
- V
In testing for 2007 to 2026.
Knock sensors average voltage bank 1, variant 2 S5_KNOCK_SENSORS_AVG_V_1_2
- Request
22 4E 70 - Service 22
DID 4E70 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2007 to 2026.
Maximum charge current S5_MAX_CHA_CUR_2Confirmed
- Request
22 11 59 - Service 22
DID 1159 - Module
7E0 → 7E8 - Every
1 s - Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0000 = 0 → (0 ÷ 10) = 0 A
- Formula
(val ÷ 10)- Range
- -3200 to 3200 A
- Unit
- A
Confirmed for 2017, 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016, 2023.
Maximum charge voltage S5_BMS_V_CHG_MAXConfirmed
- Request
22 51 71 - Service 22
DID 5171 - Module
7E5 → 7ED - Every
1 s - Testing for 2007 to 2022, 2024 to 2026
Example reply from a 2023 Audi S5.
Bits 0 to 15 of the reply, 16 bits.
0x021C = 540 → (540 ÷ 10) = 54 V
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.
Maximum discharge current S5_MAX_DCHA_CUR_2
- Request
22 11 58 - Service 22
DID 1158 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3200 to 3200 A
- Unit
- A
In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.
Maximum dynamic charge current limit S5_BMS_I_CHG_LIM_DYNConfirmed
- Request
22 1E 1B - Service 22
DID 1E1B - Module
7E5 → 7ED - Every
1 s - Testing for 2007 to 2022, 2024 to 2026
Example reply from a 2023 Audi S5.
Bits 0 to 15 of the reply, 16 bits.
0x00C8 = 200 → 200 A
- Formula
val- Range
- 0 to 65535 A
- Unit
- A
Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.
Maximum dynamic discharge current limit S5_BMS_I_DCHG_LIM_DYNConfirmed
- Request
22 1E 1C - Service 22
DID 1E1C - Module
7E5 → 7ED - Every
1 s - Testing for 2007 to 2022, 2024 to 2026
Example reply from a 2023 Audi S5.
Bits 0 to 15 of the reply, 16 bits.
0x012C = 300 → 300 A
- Formula
val- Range
- 0 to 65535 A
- Unit
- A
Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.
Maximum predicted charge current limit S5_BMS_I_CHG_LIM_PREDConfirmed
- Request
22 1E 1D - Service 22
DID 1E1D - Module
7E5 → 7ED - Every
1 s - Testing for 2007 to 2022, 2024 to 2026
Example reply from a 2023 Audi S5.
Bits 0 to 15 of the reply, 16 bits.
0x0050 = 80 → 80 A
- Formula
val- Range
- 0 to 65535 A
- Unit
- A
Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.
Maximum predicted discharge current limit S5_BMS_I_DCHG_LIM_PREDConfirmed
- Request
22 1E 1E - Service 22
DID 1E1E - Module
7E5 → 7ED - Every
1 s - Testing for 2007 to 2022, 2024 to 2026
Example reply from a 2023 Audi S5.
Bits 0 to 15 of the reply, 16 bits.
0x0050 = 80 → 80 A
- Formula
val- Range
- 0 to 65535 A
- Unit
- A
Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.
Minimum discharge voltage S5_BMS_V_DCHG_MINConfirmed
- Request
22 51 70 - Service 22
DID 5170 - Module
7E5 → 7ED - Every
1 s - Testing for 2007 to 2022, 2024 to 2026
Example reply from a 2023 Audi S5.
Bits 0 to 15 of the reply, 16 bits.
0x0186 = 390 → (390 ÷ 10) = 39 V
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.
Minimum dynamic charge voltage S5_BMS_V_CHG_DYN_MINConfirmed
- Request
22 51 74 - Service 22
DID 5174 - Module
7E5 → 7ED - Every
1 s - Testing for 2007 to 2022, 2024 to 2026
Example reply from a 2023 Audi S5.
Bits 0 to 15 of the reply, 16 bits.
0x0212 = 530 → (530 ÷ 10) = 53 V
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.
Minimum dynamic discharge voltage S5_BMS_V_DCHG_DYN_MINConfirmed
- Request
22 51 75 - Service 22
DID 5175 - Module
7E5 → 7ED - Every
1 s - Testing for 2007 to 2022, 2024 to 2026
Example reply from a 2023 Audi S5.
Bits 0 to 15 of the reply, 16 bits.
0x0191 = 401 → (401 ÷ 10) = 40.1 V
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.
Minimum predicted charge voltage S5_BMS_V_CHG_PRED_MINConfirmed
- Request
22 51 72 - Service 22
DID 5172 - Module
7E5 → 7ED - Every
1 s - Testing for 2007 to 2022, 2024 to 2026
Example reply from a 2023 Audi S5.
Bits 0 to 15 of the reply, 16 bits.
0x01FA = 506 → (506 ÷ 10) = 50.6 V
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.
Minimum predicted discharge voltage S5_BMS_V_DCHG_PRED_MINConfirmed
- Request
22 51 73 - Service 22
DID 5173 - Module
7E5 → 7ED - Every
1 s - Testing for 2007 to 2022, 2024 to 2026
Example reply from a 2023 Audi S5.
Bits 0 to 15 of the reply, 16 bits.
0x01C1 = 449 → (449 ÷ 10) = 44.9 V
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.
Non-vehicle energy requirement S5_NV_ENERGY_REQUIREMENT
- Request
22 15 D1 - Service 22
DID 15D1 - Module
710 → 77A - Every
5 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 50 ÷ 1000)- Range
- 0 to 12.75 kWh
- Unit
- kWh
In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.
Service regeneration current duration S5_PQ35_SRV_REGEN_DUR
- Request
22 11 64 - Service 22
DID 1164 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val × 0.0001666667)- Range
- 0 to 715827 min
- Unit
- min
In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.
Temperature sensor for engine temperature management voltage S5_T_SENS_ENG_T_V
- Request
22 40 E4 - Service 22
DID 40E4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2007 to 2026.
Turbocharger inlet pressure corrected value S5_TURBOCHARGER_INLET_P
- Request
22 11 D4 - Service 22
DID 11D4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 5 ÷ 64)- Range
- 0 to 5119.9218
- Unit
- Raw value
In testing for 2007 to 2026.
Usable battery charge S5_USE_BAT_CHGConfirmed
- Request
22 2A 0F - Service 22
DID 2A0F - Module
710 → 77A - Every
5 s - Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 7 of the reply, 8 bits.
0x1E = 30 → 30 Ah
- Formula
val- Range
- 0 to 255 Ah
- Unit
- Ah
Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.
Battery › Modules
Module 3, temperature 1 S5_HVBAT_MOD3_T1Confirmed
- Request
22 18 23 - Service 22
DID 1823 - Module
7E5 → 7ED - Every
1 s - Testing for 2007 to 2022, 2024 to 2026
Example reply from a 2023 Audi S5.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → (0 − 50) = -50 °C
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
Confirmed for 2023. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2024.
Module 3, temperature 2 S5_HVBAT_MOD3_T2
- Request
22 18 23 - Service 22
DID 1823 - Module
7E5 → 7ED - Every
1 s - Testing for 2007 to 2022, 2024 to 2026
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Supported for 2023. Not supported for 2016 to 2017, 2024.
Module 3, temperature 3 S5_HVBAT_MOD3_T3
- Request
22 18 23 - Service 22
DID 1823 - Module
7E5 → 7ED - Every
1 s - Testing for 2007 to 2022, 2024 to 2026
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Supported for 2023. Not supported for 2016 to 2017, 2024.