Engine parameters
The Audi S5 has 629 engine parameters.
● Confirmed◆ In testing○ Supported× Not supported
A/C clutch S5_CLIMATE_A_C_CLCH
- Request
22 48 2B - Service 22
DID 482B - Module
746 → 7B0 - Every
2 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.
A/C compressor load S5_CLIMATE_A_C_COMP_LOAD
- Request
22 26 04 - Service 22
DID 2604 - Module
746 → 7B0 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 N·m
- Unit
- N·m
In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.
A/C compressor torque S5_A_C_COMPRESSOR_TORQUE
- Request
22 10 1A - Service 22
DID 101A - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2007 to 2026.
A/C refrigerant pressure S5_A_C_REFRIGERANT_PRES
- Request
22 10 17 - Service 22
DID 1017 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 2)- Range
- -65536 to 65534
- Unit
- Raw value
In testing for 2007 to 2026.
Adaptation of loss torque S5_ADPT_LOSS_TQ
- Request
22 29 29 - Service 22
DID 2929 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 N·m
- Unit
- N·m
In testing for 2007 to 2026.
Adaptation of throttle valve S5_ADPT_THROTTLE_VLV
- Request
22 29 2B - Service 22
DID 292B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2026.
Adaptation val.cylinder1 fast diagnosis S5_ADPT_VAL_CYL1_FAST
- Request
22 3F 45 - Service 22
DID 3F45 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53
- Unit
- Number
In testing for 2007 to 2026.
Adaptation val.cylinder1 slow diagnosis S5_ADPT_VAL_CYL1_SLOW
- Request
22 3F 41 - Service 22
DID 3F41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53
- Unit
- Number
In testing for 2007 to 2026.
Adaptation val.cylinder2 fast diagnosis S5_ADPT_VAL_CYL2_FAST
- Request
22 3F 48 - Service 22
DID 3F48 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53
- Unit
- Number
In testing for 2007 to 2026.
Adaptation val.cylinder2 slow diagnosis S5_ADPT_VAL_CYL2_SLOW
- Request
22 3F 44 - Service 22
DID 3F44 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53
- Unit
- Number
In testing for 2007 to 2026.
Adaptation val.cylinder3 fast diagnosis S5_ADPT_VAL_CYL3_FAST
- Request
22 3F 46 - Service 22
DID 3F46 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53
- Unit
- Number
In testing for 2007 to 2026.
Adaptation val.cylinder3 slow diagnosis S5_ADPT_VAL_CYL3_SLOW
- Request
22 3F 42 - Service 22
DID 3F42 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53
- Unit
- Number
In testing for 2007 to 2026.
Adaptation val.cylinder4 fast diagnosis S5_ADPT_VAL_CYL4_FAST
- Request
22 3F 47 - Service 22
DID 3F47 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53
- Unit
- Number
In testing for 2007 to 2026.
Adaptation val.cylinder4 slow diagnosis S5_ADPT_VAL_CYL4_SLOW
- Request
22 3F 43 - Service 22
DID 3F43 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53
- Unit
- Number
In testing for 2007 to 2026.
Adaptive mode S5_ADAPTIVE_MODE
- Request
22 10 11 - Service 22
DID 1011 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2026.
Air conditioning compressor pressure, linear raw value S5_AC_COMP_P_LINEAR_RAW
- Request
22 15 C7 - Service 22
DID 15C7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2)- Range
- 0 to 131070
- Unit
- Raw value
In testing for 2007 to 2026.
Air conditioning compressor refrigerant pressure S5_AC_COMP_REFRIGERANT_P
- Request
22 10 48 - Service 22
DID 1048 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 2)- Range
- -65536 to 65534
- Unit
- Raw value
In testing for 2007 to 2026.
Air conditioning compressor torque S5_AC_COMP_TQ
- Request
22 20 17 - Service 22
DID 2017 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 N·m
- Unit
- N·m
In testing for 2007 to 2026.
Air conditioning compressor torque request S5_AC_COMP_TQ_REQ
- Request
22 10 23 - Service 22
DID 1023 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 N·m
- Unit
- N·m
In testing for 2007 to 2026.
Air conditioning refrigerant pressure S5_AC_REFRIGERANT_P
- Request
22 41 2A - Service 22
DID 412A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 2)- Range
- -65536 to 65534
- Unit
- Raw value
In testing for 2007 to 2026.
Air filling S5_AIR_FILLING
- Request
22 12 1C - Service 22
DID 121C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 11719 ÷ 500000)- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Air leakage S5_AIR_LEAKAGE
- Request
22 11 B8 - Service 22
DID 11B8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5
- Unit
- Raw value
In testing for 2007 to 2026.
Air mass meter 1 S5_MQB_AIR_MASS_1
- Request
22 10 24 - Service 22
DID 1024 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 1000 ÷ 10000)- Range
- -3276.8 to 3276.7
- Unit
- Raw value
In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.
Air mass, actual value, mg/stroke S5_AIR_MASS_ACT_MG
- Request
22 29 D1 - Service 22
DID 29D1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67
- Unit
- Raw value
In testing for 2007 to 2026.
Air mass, specified value S5_AIR_MASS_SPEC
- Request
22 10 4C - Service 22
DID 104C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276
- Unit
- Raw value
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Air pollution level S5_CLIMATE_AIR_POLUTION_LVLConfirmed
- Request
22 26 ED - Service 22
DID 26ED - Module
746 → 7B0 - Every
5 s - Testing for 2007 to 2016, 2018 to 2026
Example reply from a 2017 Audi S5.
Bits 0 to 7 of the reply, 8 bits. The value is signed.
0x00 = 0 → (0 ÷ 10) = 0
- Formula
(val ÷ 10)- Range
- -12.8 to 12.7
- Unit
- Number
Confirmed for 2017. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016.
Ambient air pressure S5_AMBIENT_AIR_P
- Request
22 15 09 - Service 22
DID 1509 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 39 ÷ 1000)- Range
- 0 to 2555.8649
- Unit
- Raw value
In testing for 2007 to 2026.
Ambient air temperature S5_DASH_AMBIENT_AIR_TConfirmed
- Request
22 10 14 - Service 22
DID 1014 - Module
714 → 77E - Every
5 s - Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 7 of the reply, 8 bits.
0x71 = 113 → (113 ÷ 2 − 50) = 6.5 °C
- Formula
(val ÷ 2 − 50)- Range
- -50 to 77.5 °C
- Unit
- °C
Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.
Ambient air temperature, v1 S5_AAT_V1Confirmed
- Request
22 14 F8 - Service 22
DID 14F8 - Module
7E0 → 7E8 - Every
5 s - Testing for 2007 to 2016, 2018 to 2026
Example reply from a 2017 Audi S5.
Bits 0 to 15 of the reply, 16 bits.
0x0BEB = 3051 → (3051 × 0.18 − 460) = 89.18 °F
- Formula
(val × 0.18 − 460)- Range
- -460 to 11336.3 °F
- Unit
- °F
Confirmed for 2017. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016.
Ambient temperature S5_AAT_7E0
- Request
22 10 00 - Service 22
DID 1000 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 3 ÷ 4 − 48)- Range
- -48 to 143 °C
- Unit
- °C
In testing for 2007 to 2026.
Ambient temperature S5_AAT_7E0_2
- Request
22 11 23 - Service 22
DID 1123 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2007 to 2026.
Analysis, clutch 1, maximum temperature S5_ANALYSIS_CLU_1_MAX_T
- Request
22 10 64 - Service 22
DID 1064 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
val- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2007 to 2026.
Analysis, clutch 2, maximum temperature S5_ANALYSIS_CLU_2_MAX_T
- Request
22 10 79 - Service 22
DID 1079 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
val- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2007 to 2026.
Automatic engine starts counter S5_AUTOMATIC_ENG_STARTS
- Request
22 29 99 - Service 22
DID 2999 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Automatic transmission fluid temperature, lifetime max S5_ATF_MAX
- Request
22 70 4F - Service 22
DID 704F - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.
Aux. hydraulic pump internal temperature S5_AUX_HYDRAULIC_PMP_T
- Request
22 51 A6 - Service 22
DID 51A6 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2007 to 2026.
Aux. hydraulic pump, current S5_AUX_HYDRAULIC_PMP
- Request
22 4E 76 - Service 22
DID 4E76 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 5)- Range
- 0 to 51 A
- Unit
- A
In testing for 2007 to 2026.
Average ignition timing angle delay adjustment S5_AVG_IGN_TIM_ANG
- Request
22 29 49 - Service 22
DID 2949 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 °
- Unit
- °
In testing for 2007 to 2026.
Avg. injection time S5_AVG_INJ_TIMEConfirmed
- Request
22 12 8C - Service 22
DID 128C - Module
7E0 → 7E8 - Every
1 s - Testing for 2007 to 2023, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 31 of the reply, 32 bits.
0x0000056A = 1386 → (1386 ÷ 2500) = 0.5544 ms
- Formula
(val ÷ 2500)- Range
- 0 to 1717986 ms
- Unit
- ms
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Avg. injection time S5_AVG_INJ_TIME_7E0
- Request
22 20 03 - Service 22
DID 2003 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25 ms
- Unit
- ms
In testing for 2007 to 2026.
Basic correction factor:, cylinder 1, filtered S5_BASIC_CORR_FACTOR_1
- Request
22 17 1A - Service 22
DID 171A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 7999 ÷ 65535000)- Range
- 0 to 7.999
- Unit
- Number
In testing for 2007 to 2026.
Basic correction factor:, cylinder 2, filtered S5_BASIC_CORR_FACTOR_2
- Request
22 17 1D - Service 22
DID 171D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 7999 ÷ 65535000)- Range
- 0 to 7.999
- Unit
- Number
In testing for 2007 to 2026.
Basic correction factor:, cylinder 3, filtered S5_BASIC_CORR_FACTOR_3
- Request
22 17 1B - Service 22
DID 171B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 7999 ÷ 65535000)- Range
- 0 to 7.999
- Unit
- Number
In testing for 2007 to 2026.
Basic correction factor:, cylinder 4, filtered S5_BASIC_CORR_FACTOR_4
- Request
22 17 1C - Service 22
DID 171C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 7999 ÷ 65535000)- Range
- 0 to 7.999
- Unit
- Number
In testing for 2007 to 2026.
Battery module controller temperature, 3 S5_BMS_BMCE_T3
- Request
22 18 0E - Service 22
DID 180E - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.
Boost press before throttle: calculated actual value S5_PQ35_BOOST_P_BEFORE_THROTTLE_CALCULATED_ACT
- Request
22 18 1A - Service 22
DID 181A - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 2500)- Range
- -81920000 to 81917500
- Unit
- Raw value
In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.
Boost pressure actuator, commanded duty S5_BOOST_P_ACTUATOR_CMD
- Request
22 16 EE - Service 22
DID 16EE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.0122068184)- Range
- -399.993 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Boost pressure commanded S5_PQ35_BOOST_P_CMDConfirmed
- Request
22 11 49 - Service 22
DID 1149 - Module
7E0 → 7E8 - Every
1 s - Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0000 = 0 → 0
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
Confirmed for 2017, 2024. In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016.
Boost pressure sensor A BP_A_ACTSAE J1979Confirmed
Actual turbocharger/supercharger A boost pressure.
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bits 24 to 39 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.96875 kPa
- Unit
- kPa
Confirmed for 2024.
Boost pressure sensor B BP_B_ACTSAE J1979Confirmed
Actual turbocharger/supercharger B boost pressure.
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bits 56 to 71 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.96875 kPa
- Unit
- kPa
Confirmed for 2024.
Boost pressure, actual S5_BOOST_P_ACT
- Request
22 11 F0 - Service 22
DID 11F0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 5 ÷ 64)- Range
- 0 to 5119.9218
- Unit
- Raw value
In testing for 2007 to 2026.
Boost pressure, actual S5_BOOST_P_ACT_7E0
- Request
22 11 1E - Service 22
DID 111E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2 ÷ 25)- Range
- 0 to 5242
- Unit
- Raw value
In testing for 2007 to 2026.
Boost pressure, target S5_BOOST_P_TGT
- Request
22 11 18 - Service 22
DID 1118 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550
- Unit
- Raw value
In testing for 2007 to 2026.
Boost regulation duty, commanded value S5_BOOST_REGULATION_CMD
- Request
22 12 19 - Service 22
DID 1219 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0234384354)- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Boost regulator feedback S5_BOOST_REGULATOR_FEEDBACK
- Request
22 11 CC - Service 22
DID 11CC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.
Bypass valve high pressure turbine inlet, activation S5_BYPASS_VLV_HIGH_P_TURBINE_INLET
- Request
22 39 FF - Service 22
DID 39FF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Bypass valve high pressure turbine inlet, actual value S5_BYPASS_VLV_HIGH_P_ACT
- Request
22 39 FC - Service 22
DID 39FC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 25 ÷ 2048)- Range
- -400 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Bypass valve high pressure turbine inlet, offset closed S5_BYPASS_VLV_HIGH_P
- Request
22 39 FD - Service 22
DID 39FD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.012207)- Range
- -399.9989 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Bypass valve high pressure turbine inlet, offset open S5_BYPASS_VLV_HIGH_P_TURBINE
- Request
22 39 FE - Service 22
DID 39FE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.012207)- Range
- -399.9989 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Bypass valve high pressure turbine inlet, target value S5_BYPASS_VLV_HIGH_P_TGT
- Request
22 39 FB - Service 22
DID 39FB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 25 ÷ 2048)- Range
- -400 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Bze_q_elad S5_BZE_Q_ELAD
- Request
22 12 3A - Service 22
DID 123A - Module
710 → 77A - Every
1 s - Testing
Bits 32 to 63 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729 Ah
- Unit
- Ah
In testing for 2007 to 2026.
Bze_q_lad S5_BZE_Q_LAD
- Request
22 12 3A - Service 22
DID 123A - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729 Ah
- Unit
- Ah
In testing for 2007 to 2026.
Cabin temperature S5_CABIN_TConfirmed
- Request
22 26 13 - Service 22
DID 2613 - Module
746 → 7B0 - Every
5 s - Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x007D = 125 → (125 ÷ 10) = 12.5 °C
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.
Cabin temperature S5_IAT
- Request
22 26 13 - Service 22
DID 2613 - Module
714 → 77E - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 °C
- Unit
- °C
In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.
Calculated engine load LOAD_PCTSAE J1979Confirmed
Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.
Pelican can show this parameter as the engine load.
- Request
01 04 - Service 01
PID 04 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2016 to 2017, 2024. Supported for 2018.
Calculated oil temperature S5_PQ35_CALCULATED_OIL_TConfirmed
Pelican can show this parameter as the engine oil temperature.
- Request
22 20 A1 - Service 22
DID 20A1 - Module
7E0 → 7E8 - Every
5 s - Testing for 2007 to 2015, 2017 to 2026
Example reply from a 2016 Audi S5.
Bits 0 to 7 of the reply, 8 bits.
0x44 = 68 → (68 − 40) = 28 °C
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.
Camshaft adaptation exhaust bank 1, phase position S5_CAM_ADPT_EXH_BANK_1_PHASE
- Request
22 20 23 - Service 22
DID 2023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 2007 to 2026.
Camshaft adaptation intake bank 1, phase position S5_CAM_ADPT_INT_BANK_1_PHASE
- Request
22 20 21 - Service 22
DID 2021 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 2007 to 2026.
Camshaft adaptation intake, phase position S5_CAM_ADPT_INT_PHASE
- Request
22 10 93 - Service 22
DID 1093 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 35999 ÷ 1638350)- Range
- -720 to 719 °
- Unit
- °
In testing for 2007 to 2026.
Camshaft adaptation, counter due to knock S5_CAM_ADPT_CNT_KNOCK
- Request
22 52 3B - Service 22
DID 523B - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Camshaft adaptation, exhaust bank 1, phase position S5_CAM_ADPT_EXH_BANK_1Confirmed
- Request
22 11 28 - Service 22
DID 1128 - Module
7E0 → 7E8 - Every
1 s - Testing for 2007 to 2023, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0xFFDC = -36 → (-36 ÷ 50) = -0.72 °
- Formula
(val ÷ 50)- Range
- -655.36 to 655.34 °
- Unit
- °
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Camshaft adaptation, intake bank 1, phase position S5_CAM_ADPT_INT_BANK_1Confirmed
- Request
22 11 25 - Service 22
DID 1125 - Module
7E0 → 7E8 - Every
1 s - Testing for 2007 to 2023, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x001B = 27 → (27 ÷ 50) = 0.54 °
- Formula
(val ÷ 50)- Range
- -655.36 to 655.34 °
- Unit
- °
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Camshaft adaptation, intake deviation S5_CAM_ADPT_INT_DEV
- Request
22 4F F5 - Service 22
DID 4FF5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 128)- Range
- -256 to 255.9921 °
- Unit
- °
In testing for 2007 to 2026.
Camshaft adjustment intake bank 1, activation % S5_CAM_ADJ_INT_BANK_1
- Request
22 29 30 - Service 22
DID 2930 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Camshaft adjustment intake test bank 1 S5_CAM_ADJ_INT_TEST_1
- Request
22 39 3C - Service 22
DID 393C - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2007 to 2026.
Camshaft adjustment outlet test bank 1 S5_CAM_ADJ_OUTLET_TEST_1
- Request
22 39 3C - Service 22
DID 393C - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2007 to 2026.
Camshaft adjustment, exhaust bank 1, actual value S5_CAM_ADJ_EXH_BANK_1_ACT
- Request
22 13 6C - Service 22
DID 136C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 125)- Range
- -262.144 to 262.136 °
- Unit
- °
In testing for 2007 to 2026.
Camshaft adjustment, exhaust bank 1, specified value S5_CAM_ADJ_EXH_BANK_1_SPEC
- Request
22 13 71 - Service 22
DID 1371 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 125)- Range
- -262.144 to 262.136 °
- Unit
- °
In testing for 2007 to 2026.
Camshaft adjustment, exhaust bank 2, actual value S5_CAM_ADJ_EXH_BANK_2_ACT
- Request
22 13 6D - Service 22
DID 136D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511 °
- Unit
- °
In testing for 2007 to 2026.
Camshaft adjustment, exhaust bank 2, specified value S5_CAM_ADJ_EXH_BANK_2_SPEC
- Request
22 13 72 - Service 22
DID 1372 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 125)- Range
- -262 to 262 °
- Unit
- °
In testing for 2007 to 2026.
Camshaft adjustment, exhaust, actual value S5_CAM_ADJ_EXH_ACT
- Request
22 20 1A - Service 22
DID 201A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 2007 to 2026.
Camshaft adjustment, exhaust, specified value S5_CAM_ADJ_EXH_SPEC
- Request
22 20 19 - Service 22
DID 2019 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 2007 to 2026.
Camshaft adjustment, intake bank 1, actual value S5_CAM_ADJ_INT_BANK_1_ACT
- Request
22 13 6E - Service 22
DID 136E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 125)- Range
- -262.144 to 262.136 °
- Unit
- °
In testing for 2007 to 2026.
Camshaft adjustment, intake bank 1, specified value S5_CAM_ADJ_INT_BANK_1_SPEC
- Request
22 13 73 - Service 22
DID 1373 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 125)- Range
- -262.144 to 262.136 °
- Unit
- °
In testing for 2007 to 2026.
Camshaft adjustment, intake, actual value S5_CAM_ADJ_INT_ACT
- Request
22 20 1E - Service 22
DID 201E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 2007 to 2026.
Camshaft adjustment, intake, specified value S5_CAM_ADJ_INT_SPEC
- Request
22 20 1D - Service 22
DID 201D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 2007 to 2026.
Camshaft end position S5_PQ35_CAMS_ENDConfirmed
- Request
22 13 41 - Service 22
DID 1341 - Module
7E0 → 7E8 - Every
1 s - Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x00D3 = 211 → (211 ÷ 5) = 42.2 °
- Formula
(val ÷ 5)- Range
- -6553.6 to 6553.4 °
- Unit
- °
Confirmed for 2017, 2024. In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016.
Camshaft position, deviation from the base position S5_CAM_POS_DEV_BASE_POS
- Request
22 13 85 - Service 22
DID 1385 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.021973)- Range
- -720.0112 to 719.9892 °
- Unit
- °
In testing for 2007 to 2026.
Camshaft start position S5_PQ35_CAMS_START
- Request
22 10 07 - Service 22
DID 1007 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 5)- Range
- -6553.6 to 6553.4 °
- Unit
- °
In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016 to 2017, 2024.
Cat. converter oxygen storage capacity measured S5_CAT_CONVERTER_OXYGEN_STORAGE_CAPACITY_MEASURED
- Request
22 15 07 - Service 22
DID 1507 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 1000 ÷ 10000)- Range
- 0 to 6553.5
- Unit
- Raw value
In testing for 2007 to 2026.
Cat. temperature, bank 1 S5_CAT_T_BANK_1
- Request
22 12 98 - Service 22
DID 1298 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 273.15)- Range
- -273 to 3822 °C
- Unit
- °C
In testing for 2007 to 2026.
Cat. temperature, bank 2 S5_CAT_T_BANK_2
- Request
22 12 99 - Service 22
DID 1299 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 273.15)- Range
- -273 to 3822 °C
- Unit
- °C
In testing for 2007 to 2026.
Catalyst temperature, calculated S5_CAT_T_CALC
- Request
22 15 15 - Service 22
DID 1515 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 5 − 50)- Range
- -50 to 1225 °C
- Unit
- °C
In testing for 2007 to 2026.
Centrifugal oil temperature S5_PQ35_CENTRIFUGAL_OIL_T
- Request
22 38 B2 - Service 22
DID 38B2 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127
- Unit
- Number
In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.
Chain elongation inlet, mileage at last adaptation S5_CHAIN_ELONGATION_INLET
- Request
22 51 6C - Service 22
DID 516C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
val- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2007 to 2026.
Chain elongation outlet, mileage at last adaptation S5_CHAIN_ELONGATION
- Request
22 51 49 - Service 22
DID 5149 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
val- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2007 to 2026.
Chain elongation, no of valid initial values, exhaust bank 1 S5_CHAIN_ELONGATION_NO_VALID_1
- Request
22 41 89 - Service 22
DID 4189 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2026.
Chain elongation, no of valid initial values, intake bank 1 S5_CHAIN_ELONGATION_NO_1
- Request
22 41 87 - Service 22
DID 4187 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2026.
Charge air cooler downstream air pressure S5_AIR_P_CAC_DS
- Request
22 10 56 - Service 22
DID 1056 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2007 to 2026.
Clutch #1 maximum temperature S5_PQ35_CLUTCH_1_MAXIMUM_TConfirmed
- Request
22 11 18 - Service 22
DID 1118 - Module
7E1 → 7E9 - Every
3600 s - Testing for 2007 to 2015, 2018 to 2026
Example reply from a 2017 Audi S5.
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → 0 °C
- Formula
val- Range
- 0 to 65535 °C
- Unit
- °C
Confirmed for 2017. In testing for 2007 to 2015, 2018 to 2026. Supported for 2016.
Clutch #2 maximum temperature S5_PQ35_CLUTCH_2_MAXIMUM_TConfirmed
- Request
22 11 18 - Service 22
DID 1118 - Module
7E1 → 7E9 - Every
3600 s - Testing for 2007 to 2015, 2018 to 2026
Example reply from a 2017 Audi S5.
Bits 16 to 31 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → 0 °C
- Formula
val- Range
- 0 to 65535 °C
- Unit
- °C
Confirmed for 2017. In testing for 2007 to 2015, 2018 to 2026. Supported for 2016.
Clutch 0 temperature calculated S5_MQB_DL382_CLUTCH_0_T_CALCULATEDConfirmed
- Request
22 12 0F - Service 22
DID 120F - Module
7E1 → 7E9 - Every
5 s - Testing for 2007 to 2015, 2017 to 2026
Example reply from a 2016 Audi S5.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x02B8 = 696 → 696 °C
- Formula
val- Range
- -32768 to 32767 °C
- Unit
- °C
Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.
Clutch 1 temperature S5_PQ35_CLUTCH_1_TConfirmed
- Request
22 10 2B - Service 22
DID 102B - Module
7E1 → 7E9 - Every
5 s - Testing for 2007 to 2015, 2018 to 2026
Example reply from a 2017 Audi S5.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0 °C
- Formula
val- Range
- 0 to 255 °C
- Unit
- °C
Confirmed for 2016 to 2017. In testing for 2007 to 2015, 2018 to 2026.
Clutch 1 temperature protection overheat protection 1 quantity S5_MQB_TCM_CLUTCH_1_T_PROTECTION_OVERHEAT_PROTECTION_1_QTY
- Request
22 38 81 - Service 22
DID 3881 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.
Clutch 1 temperature protection warning 1 quantity S5_MQB_TCM_CLUTCH_1_T_PROTECTION_WARNING_1_QTY
- Request
22 38 7F - Service 22
DID 387F - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.
Clutch 1 temperature protection warning 2 quantity S5_MQB_TCM_CLUTCH_1_T_PROTECTION_WARNING_2_QTY
- Request
22 38 80 - Service 22
DID 3880 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.
Clutch 2 temperature S5_PQ35_CLUTCH_2_TConfirmed
- Request
22 10 2C - Service 22
DID 102C - Module
7E1 → 7E9 - Every
5 s - Testing for 2007 to 2015, 2018 to 2026
Example reply from a 2017 Audi S5.
Bits 0 to 7 of the reply, 8 bits.
0xA3 = 163 → 163 °C
- Formula
val- Range
- 0 to 255 °C
- Unit
- °C
Confirmed for 2016 to 2017. In testing for 2007 to 2015, 2018 to 2026.
Clutch 2 temperature protection overheat protection 1 quantity S5_MQB_TCM_CLUTCH_2_T_PROTECTION_OVERHEAT_PROTECTION_1_QTY
- Request
22 38 85 - Service 22
DID 3885 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.
Clutch 2 temperature protection warning 1 quantity S5_MQB_TCM_CLUTCH_2_T_PROTECTION_WARNING_1_QTY
- Request
22 38 83 - Service 22
DID 3883 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.
Clutch 2 temperature protection warning 2 quantity S5_MQB_TCM_CLUTCH_2_T_PROTECTION_WARNING_2_QTY
- Request
22 38 84 - Service 22
DID 3884 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.
Clutch center central plate temperature S5_CLU_CENTER_CENTRAL_T
- Request
22 10 2A - Service 22
DID 102A - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
val- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2007 to 2026.
Clutch temperature calculated S5_MQB_DL382_CLUTCH_T_CALCULATED
- Request
22 18 E3 - Service 22
DID 18E3 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.
Commanded boost pressure A BP_A_CMDSAE J1979Confirmed
Turbocharger/supercharger A commanded boost pressure.
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.96875 kPa
- Unit
- kPa
Confirmed for 2024.
Commanded boost pressure B BP_B_CMDSAE J1979Confirmed
Turbocharger/supercharger B commanded boost pressure.
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bits 40 to 55 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.96875 kPa
- Unit
- kPa
Confirmed for 2024.
Commanded crankshaft torque S5_CMD_CRANK_TQ
- Request
22 11 E0 - Service 22
DID 11E0 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2007 to 2026.
Commanded equivalence ratio EQ_RATSAE J1979Confirmed
Fuel systems that utilize conventional oxygen sensor display the inverse of the commanded open loop equivalence ratio (also known as lambda) while the fuel control system is in open loop. Will indicate 1.000 while in closed-loop fuel.
Pelican can show this parameter as the commanded lambda.
- Request
01 44 - Service 01
PID 44 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2 ÷ 65535)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2016 to 2017, 2024. Supported for 2018.
Compression test cylinder 1 S5_PQ35_COMPRESSION_TEST_CYL_1Confirmed
- Request
22 11 29 - Service 22
DID 1129 - Module
7E0 → 7E8 - Every
3600 s - Testing for 2007 to 2016, 2018 to 2026
Example reply from a 2017 Audi S5.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0000 = 0 → (0 ÷ 2) = 0 rpm
- Formula
(val ÷ 2)- Range
- -16384 to 16383.5 rpm
- Unit
- rpm
Confirmed for 2017. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016.
Compression test cylinder 2 S5_PQ35_COMP_TEST_CYL_2
- Request
22 11 2A - Service 22
DID 112A - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 2)- Range
- -16384 to 16383.5 rpm
- Unit
- rpm
In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.
Compression test cylinder 3 S5_PQ35_COMP_TEST_CYL_3
- Request
22 11 2B - Service 22
DID 112B - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 2)- Range
- -16384 to 16383.5 rpm
- Unit
- rpm
In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.
Compression test, cylinder 1 S5_COMPRESSION_TEST_CYL_1
- Request
22 29 9B - Service 22
DID 299B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 2007 to 2026.
Compression test, cylinder 2 S5_COMPRESSION_TEST_CYL_2
- Request
22 29 9C - Service 22
DID 299C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 2007 to 2026.
Compression test, cylinder 3 S5_COMPRESSION_TEST_CYL_3
- Request
22 29 9D - Service 22
DID 299D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 2007 to 2026.
Compression test, cylinder 4 S5_COMPRESSION_TEST_CYL_4
- Request
22 29 9E - Service 22
DID 299E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 2007 to 2026.
Control module temperature S5_CTRL_MODULE_T
- Request
22 03 01 - Service 22
DID 0301 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2007 to 2026.
Control module temperature S5_ENG_CTRL_MODULE_TConfirmed
- Request
22 02 8D - Service 22
DID 028D - Module
7E0 → 7E8 - Every
5 s - Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0B58 = 2904 → (2904 ÷ 10 − 273.1) = 17.3 °C
- Formula
(val ÷ 10 − 273.1)- Range
- -40 to 150 °C
- Unit
- °C
Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.
Control module temperature S5_MQB_TCM_ECU_T
- Request
22 02 8D - Service 22
DID 028D - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.
Converter loss torque S5_MQB_TCM_CONVERTER_LOSS_TORQUEConfirmed
- Request
22 10 10 - Service 22
DID 1010 - Module
7E1 → 7E9 - Every
250 ms - Testing for 2007 to 2015, 2017 to 2026
Example reply from a 2016 Audi S5.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0046 = 70 → (70 ÷ 20) = 3.5 N·m
- Formula
(val ÷ 20)- Range
- -1638.4 to 1638.35 N·m
- Unit
- N·m
Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.
Coolant circulation pump, activation S5_CLT_CIRCULATION_PMP_ACTIVATION
- Request
22 27 6D - Service 22
DID 276D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Coolant circulation pump, control S5_CLT_CIRCULATION_PMP
- Request
22 16 7E - Service 22
DID 167E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Coolant fan 1 activation, $1117 S5_CLT_FAN_1_ACTIVATION_1117
- Request
22 11 17 - Service 22
DID 1117 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327 %
- Unit
- %
In testing for 2007 to 2026.
Coolant fan 1 duty cycle S5_PQ35_COOL_FAN_1_DUTYConfirmed
- Request
22 11 16 - Service 22
DID 1116 - Module
7E0 → 7E8 - Every
1 s - Testing for 2007 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024. In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016 to 2017.
Coolant fan 1, activation S5_CLT_FAN_1_ACTIVATION
- Request
22 20 55 - Service 22
DID 2055 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Coolant fan 1, activation S5_COOLANT_FAN_1_ACTIVATION
- Request
22 11 30 - Service 22
DID 1130 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 100 ÷ 10000)- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Coolant fan 2 duty cycle S5_PQ35_COOL_FAN_2_DUTY
- Request
22 11 14 - Service 22
DID 1114 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016 to 2017, 2024.
Coolant fan 2, activation S5_CLT_FAN_2_ACTIVATION
- Request
22 20 56 - Service 22
DID 2056 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Coolant fan, requested by A/C S5_CLT_FAN_REQ_AC
- Request
22 10 18 - Service 22
DID 1018 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 12207 ÷ 1000000)- Range
- -399.9989 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Coolant shut-off valve, closed S5_CLT_SHUT_OFF_VLV
- Request
22 26 82 - Service 22
DID 2682 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127
- Unit
- Number
In testing for 2007 to 2026.
Coolant temperature at engine outlet, calculated S5_COOLANT_T_AT_ENGINE_OUTLET_CALCULATED
- Request
22 44 90 - Service 22
DID 4490 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1)- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2007 to 2026.
Coolant temperature at engine outlet, calculated S5_ECT_ENG_OUTLET_CALC
- Request
22 10 64 - Service 22
DID 1064 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2007 to 2026.
Coolant temperature at engine start S5_COOLANT_T_AT_ENGINE_START
- Request
22 12 91 - Service 22
DID 1291 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1)- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2007 to 2026.
Coolant temperature at engine start S5_ECT_ENG_START
- Request
22 29 35 - Service 22
DID 2935 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2007 to 2026.
Coolant temperature at radiator outlet S5_COOLANT_TConfirmed
- Request
22 11 35 - Service 22
DID 1135 - Module
7E0 → 7E8 - Every
5 s - Testing for 2007 to 2015, 2018 to 2026
Example reply from a 2017 Audi S5.
Bits 0 to 15 of the reply, 16 bits.
0x0E6C = 3692 → (3692 ÷ 10 − 273.1) = 96.1 °C
- Formula
(val ÷ 10 − 273.1)- Range
- -273.1 to 6280.4 °C
- Unit
- °C
Confirmed for 2016 to 2017. In testing for 2007 to 2015, 2018 to 2026.
Coolant temperature at radiator outlet S5_ECT_RADIATOR_OUTLET
- Request
22 11 B5 - Service 22
DID 11B5 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2007 to 2026.
Coolant temperature at radiator outlet 2 S5_ECT_RAD_OUT_2
- Request
22 10 9B - Service 22
DID 109B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2007 to 2026.
Coolant temperature at radiator outlet v.1 S5_ECT_RADIATOR_OUTLET_V_1
- Request
22 15 CD - Service 22
DID 15CD - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1)- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2007 to 2026.
Coolant temperature at radiator outlet, actual value S5_ECT_RADIATOR_OUTLET_ACT
- Request
22 20 2B - Service 22
DID 202B - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2007 to 2026.
Coolant temperature at radiator outlet, actual value S5_ECT_RADIATOR_OUTLET_ACT_7E0
- Request
22 10 2C - Service 22
DID 102C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2007 to 2026.
Coolant temperature at radiator outlet, specified value S5_ECT_RADIATOR_OUTLET_SPEC
- Request
22 20 2C - Service 22
DID 202C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2007 to 2026.
Coolant temperature difference between engine and radiator S5_ECT_DIFF_ENG
- Request
22 20 2E - Service 22
DID 202E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2007 to 2026.
Coolant temperature linear S5_ECT_LINEAR
- Request
22 15 13 - Service 22
DID 1513 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 29297 ÷ 10000000 − 48)- Range
- -48 to 143.9978 °C
- Unit
- °C
In testing for 2007 to 2026.
Coolant temperature modeled value S5_COOLANT_T_MODELED_VALUE
- Request
22 13 A0 - Service 22
DID 13A0 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1)- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2007 to 2026.
Coolant temperature, maximum value S5_ECT_MAX
- Request
22 15 11 - Service 22
DID 1511 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 3 ÷ 4 − 48)- Range
- -48 to 143.25 °C
- Unit
- °C
In testing for 2007 to 2026.
Coolant temperature, minimum value S5_ECT_MIN
- Request
22 15 12 - Service 22
DID 1512 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 3 ÷ 4 − 48)- Range
- -48 to 143.25 °C
- Unit
- °C
In testing for 2007 to 2026.
Correction factor of oil temperature for engine protection S5_CORR_FACTOR_OIL_T
- Request
22 3F 4F - Service 22
DID 3F4F - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 12207 ÷ 100000000)- Range
- 0 to 7.99
- Unit
- Number
In testing for 2007 to 2026.
Correction values for main pressure adaptation S5_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPTConfirmed
- Request
22 11 A7 - Service 22
DID 11A7 - Module
7E1 → 7E9 - Every
3600 s - Testing for 2007 to 2015, 2017 to 2026
Example reply from a 2016 Audi S5.
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
0x0800 = 2048 → (2048 ÷ 100) = 20.48 bar
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 bar
- Unit
- bar
Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.
Counter steer support S5_CNT_STEER_SUPPORT_ACTIVE
- Request
22 18 B6 - Service 22
DID 18B6 - Module
713 → 77D - Every
900 s - Testing
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.
Counter steer support, steering torque S5_CNT_STEER_SUPPORT_STEERING_TRQ
- Request
22 18 B6 - Service 22
DID 18B6 - Module
713 → 77D - Every
900 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 1 N·m
- Unit
- N·m
In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.
Crankshaft rotation angle when closing the quantity control valve S5_CRANK_ROT_ANG
- Request
22 10 EB - Service 22
DID 10EB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 2007 to 2026.
Critical engine oil level S5_PQ35_OIL_LVL_CRITConfirmed
- Request
22 11 BD - Service 22
DID 11BD - Module
7E0 → 7E8 - Every
1 s - Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0B5F = 2911 → (2911 ÷ 250) = 11.644 mm
- Formula
(val ÷ 250)- Range
- -131.072 to 131.068 mm
- Unit
- mm
Confirmed for 2017, 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016, 2023.
CTR_MIS_DC_MMV_CYL_SAE, 0 S5_CTR_MIS_DC_MMV_CYL_0
- Request
22 14 8D - Service 22
DID 148D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
CTR_MIS_DC_MMV_CYL_SAE, 1 S5_CTR_MIS_DC_MMV_CYL_1
- Request
22 14 8E - Service 22
DID 148E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
CTR_MIS_DC_MMV_CYL_SAE, 2 S5_CTR_MIS_DC_MMV_CYL_2
- Request
22 14 8F - Service 22
DID 148F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Current N215 pressure control valve 1 S5_CURRENT_N215_P_CTRL_1
- Request
22 10 24 - Service 22
DID 1024 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 mA
- Unit
- mA
In testing for 2007 to 2026.
Current N216 pressure control valve 2 S5_CURRENT_N216_P_CTRL_2
- Request
22 10 26 - Service 22
DID 1026 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 mA
- Unit
- mA
In testing for 2007 to 2026.
Current N217 pressure control valve 3 S5_CURRENT_N217_P_CTRL_3
- Request
22 10 28 - Service 22
DID 1028 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 mA
- Unit
- mA
In testing for 2007 to 2026.
Current N218 pressure control valve 4 S5_CURRENT_N218_P_CTRL_4
- Request
22 10 25 - Service 22
DID 1025 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 mA
- Unit
- mA
In testing for 2007 to 2026.
Current N233 pressure control valve 5 S5_CURRENT_N233_P_CTRL_5
- Request
22 10 27 - Service 22
DID 1027 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 mA
- Unit
- mA
In testing for 2007 to 2026.
Current solenoid S5_CURRENT_SOLENOID
- Request
22 10 37 - Service 22
DID 1037 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 mA
- Unit
- mA
In testing for 2007 to 2026.
Current type of driver counter S5_CURRENT_TYPE_DRIVER
- Request
22 10 13 - Service 22
DID 1013 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Cylinder 1 internal torque S5_CYL_1_INTERNAL_TQ
- Request
22 58 47 - Service 22
DID 5847 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2007 to 2026.
Cylinder 2 internal torque S5_CYL_2_INTERNAL_TQ
- Request
22 58 49 - Service 22
DID 5849 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2007 to 2026.
Cylinder 3 internal torque S5_CYL_3_INTERNAL_TQ
- Request
22 58 4B - Service 22
DID 584B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2007 to 2026.
Cylinder 4 internal torque S5_CYL_4_INTERNAL_TQ
- Request
22 58 4D - Service 22
DID 584D - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2007 to 2026.
Cylinder block temperature sensor S5_CYL_BLOCK_T_SENS
- Request
22 51 D4 - Service 22
DID 51D4 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1)- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2007 to 2026.
Cylinder head temperature S5_CYL_HEAD_T
- Request
22 10 65 - Service 22
DID 1065 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 9 ÷ 50 − 460)- Range
- -460 to 11336.3 °F
- Unit
- °F
In testing for 2007 to 2026.
Desired torque raw S5_DES_TQ_RAW
- Request
22 10 61 - Service 22
DID 1061 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 N·m
- Unit
- N·m
In testing for 2007 to 2026.
Diesel particulate filter differential pressure variant 2 S5_PQ35_DPF_DIFF_P_2Confirmed
- Request
22 10 F3 - Service 22
DID 10F3 - Module
7E0 → 7E8 - Every
1 s - Testing for 2007 to 2015, 2017 to 2026
Example reply from a 2016 Audi S5.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0803 = 2051 → 2,051
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
Confirmed for 2016. In testing for 2007 to 2015, 2017 to 2026.
Diesel particulate filter exhaust gas flow volume S5_MQB_DPF_EXH_VOLConfirmed
- Request
22 11 E6 - Service 22
DID 11E6 - Module
7E0 → 7E8 - Every
1 s - Testing for 2007 to 2016, 2018 to 2026
Example reply from a 2017 Audi S5.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0000 = 0 → (0 × 1000 ÷ 10000) = 0
- Formula
(val × 1000 ÷ 10000)- Range
- -3276.8 to 3276.7
- Unit
- Number
Confirmed for 2017. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016.
Diesel particulate filter surface temperature S5_DPF_SFC_TConfirmed
- Request
22 10 44 - Service 22
DID 1044 - Module
7E0 → 7E8 - Every
1 s - Testing for 2007 to 2015, 2017 to 2026
Example reply from a 2016 Audi S5.
Bits 0 to 15 of the reply, 16 bits.
0x00A9 = 169 → (169 ÷ 10 − 273.1) = -256.2 °C
- Formula
(val ÷ 10 − 273.1)- Range
- -273.1 to 3003.6 °C
- Unit
- °C
Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.
Differential pressure S5_PQ35_DIFF_P
- Request
22 14 F5 - Service 22
DID 14F5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2007 to 2026.
Direct injections counter S5_DIRECT_INJECTIONS
- Request
22 42 67 - Service 22
DID 4267 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2007 to 2026.
Driver demand torque S5_MQB_TCM_DRIVER_DEMAND_TORQUE
- Request
22 10 0B - Service 22
DID 100B - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 20)- Range
- -1638.4 to 1638.35 N·m
- Unit
- N·m
In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.
Driving mode sensor, hall sensor a S5_DRIVING_MODE_SENS
- Request
22 21 0D - Service 22
DID 210D - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2026.
Driving position S5_DRIVING_POS
- Request
22 21 0E - Service 22
DID 210E - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2026.
Driving resistance index S5_DRIVING_RES_INDEX
- Request
22 21 08 - Service 22
DID 2108 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 128)- Range
- -128 to 127
- Unit
- Number
In testing for 2007 to 2026.
Dynamic average of ignition angle delay adjustment S5_DYNAMIC_AVG_IGN_ANG
- Request
22 29 4A - Service 22
DID 294A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 °
- Unit
- °
In testing for 2007 to 2026.
Ea888b boost pressure control, adaptation value 0 S5_EA888B_BOOST_P_CTRL_0
- Request
22 11 FF - Service 22
DID 11FF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
(val × 281 ÷ 100)- Range
- -359.68 to 356.87
- Unit
- Raw value
In testing for 2007 to 2026.
Ea888b boost pressure control, adaptation value 1 S5_EA888B_BOOST_P_CTRL_1
- Request
22 12 00 - Service 22
DID 1200 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
(val × 281 ÷ 100)- Range
- -359.68 to 356.87
- Unit
- Raw value
In testing for 2007 to 2026.
Ea888b boost pressure control, adaptation value 2 S5_EA888B_BOOST_P_CTRL_2
- Request
22 12 01 - Service 22
DID 1201 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
(val × 281 ÷ 100)- Range
- -359.68 to 356.87
- Unit
- Raw value
In testing for 2007 to 2026.
Ea888b boost pressure control, adaptation value 3 S5_EA888B_BOOST_P_CTRL_3
- Request
22 12 02 - Service 22
DID 1202 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
(val × 281 ÷ 100)- Range
- -359.68 to 356.87
- Unit
- Raw value
In testing for 2007 to 2026.
Ea888b boost pressure regulator, commanded S5_EA888B_BOOST_P_CMD
- Request
22 11 A3 - Service 22
DID 11A3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Early ignition counter for toque reduction, cylinder 1 S5_EARLY_IGN_CNT_TOQUE_1
- Request
22 4E 4A - Service 22
DID 4E4A - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Early ignition counter for toque reduction, cylinder 2 S5_EARLY_IGN_CNT_TOQUE_2
- Request
22 4E 4A - Service 22
DID 4E4A - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Early ignition counter for toque reduction, cylinder 3 S5_EARLY_IGN_CNT_TOQUE_3
- Request
22 4E 4A - Service 22
DID 4E4A - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Early ignition counter for toque reduction, cylinder 4 S5_EARLY_IGN_CNT_TOQUE_4
- Request
22 4E 4A - Service 22
DID 4E4A - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Early ignition counter, cylinder 1 S5_EARLY_IGN_CNT_CYL_1
- Request
22 17 22 - Service 22
DID 1722 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Early ignition counter, cylinder 2 S5_EARLY_IGN_CNT_CYL_2
- Request
22 17 25 - Service 22
DID 1725 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Early ignition counter, cylinder 3 S5_EARLY_IGN_CNT_CYL_3
- Request
22 17 23 - Service 22
DID 1723 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Early ignition counter, cylinder 4 S5_EARLY_IGN_CNT_CYL_4
- Request
22 17 24 - Service 22
DID 1724 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Early ignition counter, cylinder suppress early ignition, cylinder 1 S5_EARLY_IGN_CNT_CYL_SUPPRESS_1
- Request
22 4E 49 - Service 22
DID 4E49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Early ignition counter, cylinder suppress early ignition, cylinder 2 S5_EARLY_IGN_CNT_CYL_SUPPRESS_2
- Request
22 4E 49 - Service 22
DID 4E49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Early ignition counter, cylinder suppress early ignition, cylinder 3 S5_EARLY_IGN_CNT_CYL_SUPPRESS_3
- Request
22 4E 49 - Service 22
DID 4E49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Early ignition counter, cylinder suppress early ignition, cylinder 4 S5_EARLY_IGN_CNT_CYL_SUPPRESS_4
- Request
22 4E 49 - Service 22
DID 4E49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Early ignition counter, total, cylinder 1 S5_EARLY_IGN_CNT_TOT_1
- Request
22 17 15 - Service 22
DID 1715 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Early ignition counter, total, cylinder 2 S5_EARLY_IGN_CNT_TOT_2
- Request
22 17 18 - Service 22
DID 1718 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Early ignition counter, total, cylinder 3 S5_EARLY_IGN_CNT_TOT_3
- Request
22 17 16 - Service 22
DID 1716 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Early ignition counter, total, cylinder 4 S5_EARLY_IGN_CNT_TOT_4
- Request
22 17 17 - Service 22
DID 1717 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Effective injection duration S5_EFFECTIVE_INJ_DUR
- Request
22 15 E7 - Service 22
DID 15E7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 4294967 ms
- Unit
- ms
In testing for 2007 to 2026.
EGT after catalyst, model bank b S5_EGT_AFTER_CAT_MODEL_B
- Request
22 2A E3 - Service 22
DID 2AE3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.023438 − 273.15)- Range
- -273 to 1262 °C
- Unit
- °C
In testing for 2007 to 2026.
Elector motor 1 torque S5_EM_TORQ_1Confirmed
- Request
22 11 53 - Service 22
DID 1153 - Module
7E0 → 7E8 - Every
1 s - Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x06F2 = 1778 → (1778 ÷ 32) = 55.5625 N·m
- Formula
(val ÷ 32)- Range
- -1000 to 1000 N·m
- Unit
- N·m
Confirmed for 2017, 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016, 2023.
Elector motor 3 torque S5_EM_TORQ_3Confirmed
- Request
22 11 55 - Service 22
DID 1155 - Module
7E0 → 7E8 - Every
1 s - Testing for 2007 to 2015, 2017 to 2026
Example reply from a 2016 Audi S5.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0000 = 0 → (0 ÷ 32) = 0 N·m
- Formula
(val ÷ 32)- Range
- -1000 to 1000 N·m
- Unit
- N·m
Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2017, 2023 to 2024.
Electric additional coolant pump control, high circle S5_ELEC_ADDITIONAL_CLT
- Request
22 14 88 - Service 22
DID 1488 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 12207 ÷ 1000000)- Range
- -399.9989 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Electric motor 2 torque S5_EM_TORQ_2Confirmed
- Request
22 11 54 - Service 22
DID 1154 - Module
7E0 → 7E8 - Every
1 s - Testing for 2007 to 2015, 2018 to 2023, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x063D = 1597 → (1597 ÷ 32) = 49.90625 N·m
- Formula
(val ÷ 32)- Range
- -1000 to 1000 N·m
- Unit
- N·m
Confirmed for 2016 to 2017, 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2023.
Electric motor non-vehicle power limitation S5_EM_NV_PWR_LIM
- Request
22 15 D1 - Service 22
DID 15D1 - Module
710 → 77A - Every
5 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 50)- Range
- 0 to 12750 W
- Unit
- W
In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.
Electric motor power limitation S5_EM_PWR_LIM
- Request
22 15 D1 - Service 22
DID 15D1 - Module
710 → 77A - Every
5 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val × 50)- Range
- 0 to 3276750 W
- Unit
- W
In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.
Energy balance of last driving cycle S5_ENERGY_BALANCE_LAST
- Request
22 2A 15 - Service 22
DID 2A15 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327 Ah
- Unit
- Ah
In testing for 2007 to 2026.
Energy content S5_ENERGY_CONTENT
- Request
22 22 E4 - Service 22
DID 22E4 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 kWh
- Unit
- kWh
In testing for 2007 to 2026.
Engine air mass, specified value S5_ENG_AIR_MASS_SPEC
- Request
22 20 37 - Service 22
DID 2037 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2007 to 2026.
Engine compartment temperature raw value S5_ENG_COMPARTMENT_T
- Request
22 46 B1 - Service 22
DID 46B1 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1)- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2007 to 2026.
Engine coolant temperature ECTSAE J1979Confirmed
Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.
Pelican can show this parameter as the engine coolant temperature.
- Request
01 05 - Service 01
PID 05 - Module
7E0 → 7E8 - Every
500 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2016 to 2017, 2024. Supported for 2018.
Engine drag torque S5_ENG_DRAG_TQ
- Request
22 20 9C - Service 22
DID 209C - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 N·m
- Unit
- N·m
In testing for 2007 to 2026.
Engine oil level S5_ENG_OIL_LEVEL_7E0
- Request
22 15 04 - Service 22
DID 1504 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mm
- Unit
- mm
In testing for 2007 to 2026.
Engine oil level S5_PQ35_OIL_LVL
- Request
22 11 BC - Service 22
DID 11BC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 250)- Range
- -131.072 to 131.068 mm
- Unit
- mm
In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016 to 2017, 2024.
Engine oil level current value S5_ENG_OIL_LEVEL
- Request
22 58 D1 - Service 22
DID 58D1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Engine oil pressure S5_EOP
- Request
22 15 03 - Service 22
DID 1503 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 416)- Range
- 0 to 157 psi
- Unit
- psi
In testing for 2007 to 2026.
Engine oil sump temperature S5_ENG_OIL_SUMP_T
- Request
22 15 B7 - Service 22
DID 15B7 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 9 ÷ 50 − 460)- Range
- -460 to 11336.3 °F
- Unit
- °F
In testing for 2007 to 2026.
Engine oil temperature S5_EOT
- Request
22 20 2F - Service 22
DID 202F - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2007 to 2026.
Engine oil temperature S5_EOT_7E0Confirmed
Pelican can show this parameter as the engine oil temperature.
- Request
22 10 E6 - Service 22
DID 10E6 - Module
7E0 → 7E8 - Every
5 s - Testing for 2007 to 2023, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → (0 − 60) = -60 °C
- Formula
(val − 60)- Range
- -60 to 195 °C
- Unit
- °C
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Engine oil temperature S5_EOT_7E0_7E0
- Request
22 11 02 - Service 22
DID 1102 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2007 to 2026.
Engine oil temperature measured value S5_EOT_MEAS
Pelican can show this parameter as the engine oil temperature.
- Request
22 16 32 - Service 22
DID 1632 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2007 to 2026.
Engine oil temperature sensor 2 S5_EOT_SENS_2
- Request
22 40 D5 - Service 22
DID 40D5 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2007 to 2026.
Engine oil temperature, pulse sensor S5_EOT_PULS
- Request
22 17 9E - Service 22
DID 179E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2007 to 2026.
Engine outlet coolant temperature calculated S5_ENG_OUTLET_ECT_CALC
- Request
22 10 63 - Service 22
DID 1063 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2007 to 2026.
Engine protection, torque limit S5_ENG_PROTECTION_TQ
- Request
22 2B C0 - Service 22
DID 2BC0 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2007 to 2026.
Engine radiator fan request S5_ENG_RADIATOR_FAN_REQ
- Request
22 10 0B - Service 22
DID 100B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Engine RPM RPMSAE J1979Confirmed
- Request
01 0C - Service 01
PID 0C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383.75 rpm
- Unit
- rpm
Confirmed for 2024. Supported for 2016 to 2018.
Engine start quantity S5_PQ35_ENG_START_QTY
- Request
22 10 69 - Service 22
DID 1069 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67
- Unit
- Raw value
In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.
Engine temperature control actuator S5_ENG_T_CTRL_ACTUATOR
- Request
22 3D 73 - Service 22
DID 3D73 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Engine temperature management actuator, after-run stop S5_ENG_T_MANAGEMENT_ACTUATOR_AFTER
- Request
22 44 1D - Service 22
DID 441D - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Engine temperature management actuator, duty cycle activation S5_ENG_T_MANAGEMENT_ACTUATOR
- Request
22 44 1A - Service 22
DID 441A - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Engine temperature management actuator, raw value S5_ENG_T_MANAGEMENT
- Request
22 44 19 - Service 22
DID 4419 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Engine temperature management actuator, specified value S5_ENG_T_MANAGEMENT_SPEC
- Request
22 3F E4 - Service 22
DID 3FE4 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 12207 ÷ 1000000)- Range
- -399.9989 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Engine temperature management actuator, stop open S5_ENG_T_MANAGEMENT_ACTUATOR_STOP
- Request
22 44 1C - Service 22
DID 441C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Engine torque S5_ENG_TQ
- Request
22 20 02 - Service 22
DID 2002 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2007 to 2026.
Engine torque S5_ENG_TQ_7E0
- Request
22 43 7C - Service 22
DID 437C - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2007 to 2026.
Engine torque S5_ENG_TQ_7E1
- Request
22 20 02 - Service 22
DID 2002 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 2007 to 2026.
Engine torque S5_ENGINE_TORQUEConfirmed
- Request
22 10 10 - Service 22
DID 1010 - Module
7E0 → 7E8 - Every
250 ms - Testing for 2007 to 2023, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0000 = 0 → (0 ÷ 10) = 0 N·m
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Engine torque S5_MQB_TCM_ENG_TORQUE
- Request
22 70 64 - Service 22
DID 7064 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.
Engine torque S5_MQB_TCM_ENGINE_TORQUE
- Request
22 10 0C - Service 22
DID 100C - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val ÷ 20)- Range
- -1638.4 to 1638.35 N·m
- Unit
- N·m
In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.
Engine torque S5_PQ35_ENG_TORQUEConfirmed
- Request
22 15 5A - Service 22
DID 155A - Module
7E0 → 7E8 - Every
250 ms - Testing for 2007 to 2015, 2018 to 2026
Example reply from a 2017 Audi S5.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0000 = 0 → (0 ÷ 32) = 0 N·m
- Formula
(val ÷ 32)- Range
- -1024 to 1023.968 N·m
- Unit
- N·m
Confirmed for 2016 to 2017. In testing for 2007 to 2015, 2018 to 2026.
Engine torque S5_PQ35_ENG_TRQ
- Request
22 10 47 - Service 22
DID 1047 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016 to 2017, 2024.
Engine torque limitation S5_ENG_TQ_LIM
- Request
22 10 8F - Service 22
DID 108F - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 N·m
- Unit
- N·m
In testing for 2007 to 2026.
Engine torque limitation S5_MQB_TCM_ENGINE_TORQUE_LIMITATION
- Request
22 10 0E - Service 22
DID 100E - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val ÷ 20)- Range
- -1638.4 to 1638.35 N·m
- Unit
- N·m
In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.
Engine torque loss S5_MQB_TCM_ENGINE_TORQUE_LOSS
- Request
22 10 0F - Service 22
DID 100F - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val ÷ 20)- Range
- -1638.4 to 1638.35 N·m
- Unit
- N·m
In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.
Environment data camshaft input 1 S5_PQ35_ENVD_CAM_IN_1Confirmed
- Request
22 12 13 - Service 22
DID 1213 - Module
7E0 → 7E8 - Every
1 s - Testing for 2007 to 2015, 2018 to 2026
Example reply from a 2017 Audi S5.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2016 to 2017. In testing for 2007 to 2015, 2018 to 2026.
Excessive temperature protection S5_EXCESSIVE_T
- Request
22 21 17 - Service 22
DID 2117 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2026.
Exhaust camshaft, adaptation bias S5_EXH_CAM_ADPT_BIAS
- Request
22 17 4A - Service 22
DID 174A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.021973)- Range
- -720.0112 to 719.9892 °
- Unit
- °
In testing for 2007 to 2026.
Exhaust camshaft, adaptation sensor tolerance S5_EXH_CAM_ADPT_SENS
- Request
22 17 55 - Service 22
DID 1755 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.021973)- Range
- -720.0112 to 719.9892 °
- Unit
- °
In testing for 2007 to 2026.
Exhaust gas temperature S5_EXH_GAS_T
- Request
22 F4 3C - Service 22
DID F43C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 2007 to 2026.
Exhaust gas temperature - calculated after catalyst S5_EXH_GAS_T_CALC_AFTER
- Request
22 2A E9 - Service 22
DID 2AE9 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 293 ÷ 12500 − 273.15)- Range
- -273.15 to 1262.9904 °C
- Unit
- °C
In testing for 2007 to 2026.
Exhaust gas temperature at probe before precat, model value S5_EXHAUST_GAS_T_AT_PROBE_BEFOR_PRECAT_MODEL_VALUE
- Request
22 13 9C - Service 22
DID 139C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1)- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2007 to 2026.
Exhaust gas temperature before catalyst S5_EXHAUST_GAS_T_BEFORE_CATALYST
- Request
22 12 82 - Service 22
DID 1282 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 50 − 193.93)- Range
- -193.93 to 1116.77 °C
- Unit
- °C
In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.
Exhaust gas temperature before catalytic converter S5_EXH_GAS_T_BEFORE
- Request
22 29 6F - Service 22
DID 296F - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2007 to 2026.
Exhaust gas temperature sensor 1 S5_EXH_GAS_T_SENS_1
- Request
22 29 76 - Service 22
DID 2976 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2007 to 2026.
Exhaust gas temperature sensor 1 S5_EXH_GAS_T_SENS_1_7E0
- Request
22 16 6F - Service 22
DID 166F - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Exhaust gas temperature sensor 1 S5_PQ35_EXH_GAS_T_1
- Request
22 10 FB - Service 22
DID 10FB - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1)- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.
Exhaust gas temperature sensor 1, bank 2 S5_EXH_GAS_T_SENS_1_2
- Request
22 16 70 - Service 22
DID 1670 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Exhaust gas temperature sensor 2 S5_PQ35_EXHAUST_GAS_T_SENSOR_2
- Request
22 14 F7 - Service 22
DID 14F7 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1)- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.
Exhaust gas temperature sensor 3 S5_EXH_GAS_T_SENS_3
- Request
22 14 BE - Service 22
DID 14BE - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Exhaust gas temperature sensor 3, bank 2 S5_EXH_GAS_T_SENS_3_2
- Request
22 15 6F - Service 22
DID 156F - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Exhaust gas temperature sensor 4 S5_EXH_GAS_T_SENS_4
- Request
22 16 6D - Service 22
DID 166D - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2007 to 2026.
Exhaust gas temperature, sensor 4, bank 2 S5_EXH_GAS_T_S4_B2
- Request
22 16 6E - Service 22
DID 166E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2007 to 2026.
Exhaust temperature before the catalyst, modeled S5_EXH_T_BEFORE_CAT
- Request
22 14 21 - Service 22
DID 1421 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2007 to 2026.
Exhaust temperature control downstream oxidation catalyst filtered model error S5_MQB_EXH_TEMP_CTRL_AFTER_CAT_MODEL_ERR
- Request
22 1A D7 - Service 22
DID 1AD7 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.
Field limit value S5_PQ35_FIELD_LIMConfirmed
- Request
22 11 F6 - Service 22
DID 11F6 - Module
7E0 - Every
1 s - Testing for 2007 to 2015, 2017 to 2026
Example reply from a 2016 Audi S5.
Bits 0 to 15 of the reply, 16 bits.
0x6673 = 26227 → (26227 ÷ 100) = 262.27
- Formula
(val ÷ 100)- Range
- 0 to 655.35
- Unit
- Raw value
Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2017, 2024.
Front left deflector temperature S5_CLIMATE_FR_L_DEFL_TConfirmed
- Request
22 26 0C - Service 22
DID 260C - Module
746 → 7B0 - Every
5 s - Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → (0 ÷ 3) = 0 °C
- Formula
(val ÷ 3)- Range
- 0 to 84.915 °C
- Unit
- °C
Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.
Front left temperature flap actual value S5_CLIMATE_FR_L_T_FLP_ACT_VALUE
- Request
22 26 22 - Service 22
DID 2622 - Module
746 → 7B0 - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.
Front right deflector temperature S5_CLIMATE_FR_R_DEFL_TConfirmed
- Request
22 26 0D - Service 22
DID 260D - Module
746 → 7B0 - Every
5 s - Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → (0 ÷ 3) = 0 °C
- Formula
(val ÷ 3)- Range
- 0 to 84.915 °C
- Unit
- °C
Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.
Front right temperature flap actual value S5_CLIMATE_FR_R_T_FLP_ACT_VALUE
- Request
22 26 26 - Service 22
DID 2626 - Module
746 → 7B0 - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.
Fuel metering valve position S5_PQ35_FUEL_METERConfirmed
- Request
22 11 48 - Service 22
DID 1148 - Module
7E0 → 7E8 - Every
1 s - Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0000 = 0 → (0 ÷ 100) = 0 %
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2017, 2024. In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016.
Fuel temperature S5_PQ35_FUEL_TConfirmed
- Request
22 16 2D - Service 22
DID 162D - Module
7E0 → 7E8 - Every
5 s - Testing for 2007 to 2016, 2018 to 2026
Example reply from a 2017 Audi S5.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → (0 ÷ 10 − 273.1) = -273.1 °C
- Formula
(val ÷ 10 − 273.1)- Range
- -273.1 to 6280.4 °C
- Unit
- °C
Confirmed for 2017. In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016, 2024.
Generator current S5_GEN_CURRENT
- Request
22 2A 1C - Service 22
DID 2A1C - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 + 9)- Range
- 0 to 6562.5 A
- Unit
- A
In testing for 2007 to 2026.
Generator load S5_PQ35_GEN_LOADConfirmed
- Request
22 10 5C - Service 22
DID 105C - Module
7E0 → 7E8 - Every
1 s - Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → (0 ÷ 100) = 0 %
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2017, 2024. In testing for 2007 to 2016, 2018 to 2023, 2025 to 2026.
Generator load normalized value S5_GENERATOR_LOAD_NORMALIZED_VALUE
- Request
22 15 CA - Service 22
DID 15CA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Generator load signal S5_GEN_LOAD_SIG
- Request
22 20 50 - Service 22
DID 2050 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Generator load signal S5_GEN_LOAD_SIG_7E0
- Request
22 10 33 - Service 22
DID 1033 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327 %
- Unit
- %
In testing for 2007 to 2026.
Generator load signal S5_GENERATOR_LOAD_SIG
- Request
22 10 1C - Service 22
DID 101C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Generator performance S5_GENERATOR_PERFORMANCE
- Request
22 10 97 - Service 22
DID 1097 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 94248 ÷ 10000)- Range
- -308831.8464 to 308822.421 W
- Unit
- W
In testing for 2007 to 2026.
Generator torque request S5_GENERATOR_TORQUE_REQUEST
- Request
22 10 1B - Service 22
DID 101B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2007 to 2026.
Heater circulation pump, nominal value S5_HEATER_CIRCULATION
- Request
22 16 7F - Service 22
DID 167F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Heater support pump, specified value S5_HEATER_SUPPORT_PMP_SPEC
- Request
22 43 36 - Service 22
DID 4336 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Height correction S5_HEIGHT_CORR
- Request
22 11 36 - Service 22
DID 1136 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0000610348)- Range
- 0 to 3.9999
- Unit
- Number
In testing for 2007 to 2026.
High pressure control, adaptation S5_HIGH_P_CTRL_ADPT
- Request
22 11 D2 - Service 22
DID 11D2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 2000)- Range
- -16.384 to 16.3835
- Unit
- Raw value
In testing for 2007 to 2026.
High pressure regulation, adaptation value S5_HIGH_P_REGULATION
- Request
22 43 84 - Service 22
DID 4384 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327
- Unit
- Raw value
In testing for 2007 to 2026.
Hill descent control S5_HDC_ACTIVE
- Request
22 18 08 - Service 22
DID 1808 - Module
713 → 77D - Every
2 s - Testing
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.
Hill descent control, incline S5_HDC_INCLINE
- Request
22 18 08 - Service 22
DID 1808 - Module
713 → 77D - Every
2 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.
Hybrid temperature S5_MQB_TCM_HYBRID_TConfirmed
- Request
22 11 96 - Service 22
DID 1196 - Module
7E1 → 7E9 - Every
5 s - Testing for 2007 to 2015, 2017 to 2026
Example reply from a 2016 Audi S5.
Bits 0 to 15 of the reply, 16 bits.
0x0393 = 915 → 915 °C
- Formula
val- Range
- 0 to 65535 °C
- Unit
- °C
Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.
ID of current driving program S5_ID_CURRENT_DRIVING
- Request
22 10 12 - Service 22
DID 1012 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2026.
IGA_CYL_KNK, 0 S5_IGA_CYL_KNK_0
- Request
22 13 F2 - Service 22
DID 13F2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 3 ÷ 8 − 48)- Range
- -48 to 47.625 °
- Unit
- °
In testing for 2007 to 2026.
IGA_CYL_KNK, 1 S5_IGA_CYL_KNK_1
- Request
22 13 F3 - Service 22
DID 13F3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 3 ÷ 8 − 48)- Range
- -48 to 47.625 °
- Unit
- °
In testing for 2007 to 2026.
IGA_CYL_KNK, 2 S5_IGA_CYL_KNK_2
- Request
22 13 F4 - Service 22
DID 13F4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 3 ÷ 8 − 48)- Range
- -48 to 47.625 °
- Unit
- °
In testing for 2007 to 2026.
IGA_CYL_KNK, 3 S5_IGA_CYL_KNK_3
- Request
22 13 F5 - Service 22
DID 13F5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 3 ÷ 8 − 48)- Range
- -48 to 47.625 °
- Unit
- °
In testing for 2007 to 2026.
IGA_IGC, 0 S5_IGA_IGC_0
- Request
22 13 8A - Service 22
DID 138A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 1499 ÷ 4000 − 35.625)- Range
- -35.625 to 59.9362 °
- Unit
- °
In testing for 2007 to 2026.
IGA_IGC, 1 S5_IGA_IGC_1
- Request
22 13 8B - Service 22
DID 138B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 1499 ÷ 4000 − 35.625)- Range
- -35.625 to 59.9362 °
- Unit
- °
In testing for 2007 to 2026.
IGA_IGC, 2 S5_IGA_IGC_2
- Request
22 13 8C - Service 22
DID 138C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 1499 ÷ 4000 − 35.625)- Range
- -35.625 to 59.9362 °
- Unit
- °
In testing for 2007 to 2026.
IGA_IGC, 3 S5_IGA_IGC_3
- Request
22 13 8D - Service 22
DID 138D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 1499 ÷ 4000 − 35.625)- Range
- -35.625 to 59.9362 °
- Unit
- °
In testing for 2007 to 2026.
Ignition angle current cylinder, actual value S5_IGN_ANG_CURRENT_CYL_ACT
- Request
22 20 04 - Service 22
DID 2004 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -25 to 25 °
- Unit
- °
In testing for 2007 to 2026.
Ignition timing angle retard, cylinder 4 S5_IGNITION_TIMING_ANGLE_RETARD_C4
- Request
22 10 E5 - Service 22
DID 10E5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 75 ÷ 100)- Range
- -24576 to 24575.25 °
- Unit
- °
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Injection amount deviation cylinder 1 S5_INJ_AMOUNT_DEV_CYL_1
- Request
22 20 46 - Service 22
DID 2046 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.00036623)- Range
- -12 to 12
- Unit
- Raw value
In testing for 2007 to 2026.
Injection amount deviation cylinder 2 S5_INJ_AMOUNT_DEV_CYL_2
- Request
22 20 47 - Service 22
DID 2047 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.00036623)- Range
- -12 to 12
- Unit
- Raw value
In testing for 2007 to 2026.
Injection amount deviation cylinder 2 S5_INJ_AMOUNT_DEV_CYL_2_7E0
- Request
22 11 06 - Service 22
DID 1106 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327
- Unit
- Raw value
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Injection amount deviation cylinder 3 S5_INJ_AMOUNT_DEV_CYL_3
- Request
22 20 48 - Service 22
DID 2048 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.00036623)- Range
- -12 to 12
- Unit
- Raw value
In testing for 2007 to 2026.
Injection amount deviation cylinder 4 S5_INJ_AMOUNT_DEV_CYL_4
- Request
22 20 49 - Service 22
DID 2049 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.00036623)- Range
- -12 to 12
- Unit
- Raw value
In testing for 2007 to 2026.
Injection amount deviation cylinder 5 S5_INJ_AMOUNT_DEV_CYL_5
- Request
22 11 07 - Service 22
DID 1107 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327
- Unit
- Raw value
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Injector 1 rail pressure calibration point 1 S5_PQ35_INJ_1_RAIL_P_1Confirmed
- Request
22 10 D0 - Service 22
DID 10D0 - Module
7E0 → 7E8 - Every
3600 s - Testing for 2007 to 2015, 2017 to 2026
Example reply from a 2016 Audi S5.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0000 = 0 → (0 ÷ 20000) = 0 ms
- Formula
(val ÷ 20000)- Range
- -1.6384 to 1.63 ms
- Unit
- ms
Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2017, 2024.
Injector 1 rail pressure calibration point 2 S5_PQ35_INJ_1_RAIL_P_2Confirmed
- Request
22 10 D6 - Service 22
DID 10D6 - Module
7E0 → 7E8 - Every
3600 s - Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0050 = 80 → (80 ÷ 20000) = 0.004 ms
- Formula
(val ÷ 20000)- Range
- -1.6384 to 1.63 ms
- Unit
- ms
Confirmed for 2017, 2024. In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016.
Injector 2 rail pressure calibration point 1 S5_PQ35_INJ_2_RAIL_P_1Confirmed
- Request
22 10 D3 - Service 22
DID 10D3 - Module
7E0 → 7E8 - Every
3600 s - Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0xFFFC = -4 → (-4 ÷ 20000) = -0.0002 ms
- Formula
(val ÷ 20000)- Range
- -1.6384 to 1.63 ms
- Unit
- ms
Confirmed for 2017, 2024. In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016.
Injector 2, rail pressure calibration point 1 S5_INJ_2_RAIL_P_1Confirmed
- Request
22 10 D4 - Service 22
DID 10D4 - Module
7E0 → 7E8 - Every
1 s - Testing for 2007 to 2023, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0000 = 0 → (0 ÷ 20000) = 0 ms
- Formula
(val ÷ 20000)- Range
- -1.63 to 1.63 ms
- Unit
- ms
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Injector 3 rail pressure calibration point 1 S5_PQ35_INJ_3_RAIL_P_1Confirmed
- Request
22 10 D1 - Service 22
DID 10D1 - Module
7E0 → 7E8 - Every
3600 s - Testing for 2007 to 2015, 2017 to 2023, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x06A1 = 1697 → (1697 ÷ 20000) = 0.08485 ms
- Formula
(val ÷ 20000)- Range
- -1.6384 to 1.63 ms
- Unit
- ms
Confirmed for 2016, 2024. In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2017.
Injector 4 rail pressure calibration point 3 S5_PQ35_INJ_4_RAIL_P_3Confirmed
- Request
22 10 DE - Service 22
DID 10DE - Module
7E0 → 7E8 - Every
3600 s - Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0000 = 0 → (0 ÷ 20000) = 0 ms
- Formula
(val ÷ 20000)- Range
- -1.6384 to 1.63 ms
- Unit
- ms
Confirmed for 2017, 2024. In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016.
Injector 5, rail pressure calibration point 2 S5_INJ_5_RAIL_P_2Confirmed
- Request
22 10 DB - Service 22
DID 10DB - Module
7E0 → 7E8 - Every
1 s - Testing for 2007 to 2023, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0000 = 0 → (0 ÷ 20000) = 0 ms
- Formula
(val ÷ 20000)- Range
- -1.63 to 1.63 ms
- Unit
- ms
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Inlet flaps - actual value S5_INLET_FLAPS_ACT
- Request
22 11 9D - Service 22
DID 119D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 20 ÷ 13107)- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Inlet flaps - requested value S5_INLET_FLAPS_REQ
- Request
22 11 A0 - Service 22
DID 11A0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 20 ÷ 13107)- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Intake air temperature S5_IAT_7E0
- Request
22 10 01 - Service 22
DID 1001 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 3 ÷ 4 − 48)- Range
- -48 to 143 °C
- Unit
- °C
In testing for 2007 to 2026.
Intake air temperature before throttle valve, raw value S5_IAT_BEFORE_THROTTLE
- Request
22 15 C1 - Service 22
DID 15C1 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 3 ÷ 4 − 48)- Range
- -48 to 143.25 °C
- Unit
- °C
In testing for 2007 to 2026.
Intake air temperature in intake manifold S5_INTAKE_AIR_T_IN_INTAKE_MANIFOLD
- Request
22 14 9E - Service 22
DID 149E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 0.75 − 48)- Range
- -48 to 143.25 °C
- Unit
- °C
In testing for 2007 to 2026.
Intake air temperature raw value S5_IAT_RAW
- Request
22 15 C0 - Service 22
DID 15C0 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2007 to 2026.
Intake camshaft adaptation unit 1 phase length S5_PQ35_CAMS_ADAPT_PHASE_1
- Request
22 12 FE - Service 22
DID 12FE - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 50)- Range
- -655.36 to 655.34 °
- Unit
- °
In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016 to 2017, 2024.
Intake camshaft signal edge position adapted edge 2 S5_PQ35_CAMS_EDGE_POS_2Confirmed
- Request
22 11 89 - Service 22
DID 1189 - Module
7E0 → 7E8 - Every
1 s - Testing for 2007 to 2016, 2018 to 2026
Example reply from a 2017 Audi S5.
Bits 0 to 15 of the reply, 16 bits.
0x6480 = 25728 → (25728 ÷ 16 − 32) = 1,576 °
- Formula
(val ÷ 16 − 32)- Range
- -32 to 4063.937 °
- Unit
- °
Confirmed for 2017. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016.
Intake camshaft signal edge position adapted edge 3 S5_PQ35_CAMS_EDGE_POS_3Confirmed
- Request
22 11 8A - Service 22
DID 118A - Module
7E0 → 7E8 - Every
1 s - Testing for 2007 to 2016, 2018 to 2026
Example reply from a 2017 Audi S5.
Bits 0 to 15 of the reply, 16 bits.
0x6480 = 25728 → (25728 ÷ 16 − 32) = 1,576 °
- Formula
(val ÷ 16 − 32)- Range
- -32 to 4063.937 °
- Unit
- °
Confirmed for 2017. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016.
Intake camshaft signal edge position adapted edge 4 S5_PQ35_CAMS_EDGE_POS_4
- Request
22 11 8B - Service 22
DID 118B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 32)- Range
- -32 to 4063.937 °
- Unit
- °
In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.
Intake camshaft signal edge position adapted edge 5 S5_PQ35_CAMS_EDGE_POS_5
- Request
22 11 8C - Service 22
DID 118C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 32)- Range
- -32 to 4063.937 °
- Unit
- °
In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.
Intake camshaft signal edge position adapted edge 6 S5_PQ35_CAMS_EDGE_POS_6
- Request
22 11 8D - Service 22
DID 118D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 32)- Range
- -32 to 4063.937 °
- Unit
- °
In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.
Intake camshaft signal edge position adapted edge 7 S5_PQ35_CAMS_EDGE_POS_7
- Request
22 11 8E - Service 22
DID 118E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 32)- Range
- -32 to 4063.937 °
- Unit
- °
In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.
Intake camshaft signal edge position adapted edge 8 S5_PQ35_CAMS_EDGE_POS_8
- Request
22 11 8F - Service 22
DID 118F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 32)- Range
- -32 to 4063.937 °
- Unit
- °
In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.
Intake camshaft signal edge position adapted value edge 1 S5_PQ35_INTAKE_CAMSHAFT_SIGNAL_EDGE_POS_ADAPTED_VALUE_EDGE_1
- Request
22 17 3A - Service 22
DID 173A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 32)- Range
- -32 to 4063.937 °
- Unit
- °
In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.
Intake camshaft, adaptation bias S5_INT_CAM_ADPT_BIAS
- Request
22 17 4B - Service 22
DID 174B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.021973)- Range
- -720.0112 to 719.9892 °
- Unit
- °
In testing for 2007 to 2026.
Intake camshaft, adaptation sensor tolerance S5_INT_CAM_ADPT_SENS
- Request
22 17 40 - Service 22
DID 1740 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.021973)- Range
- -720.0112 to 719.9892 °
- Unit
- °
In testing for 2007 to 2026.
Intake manifold pressure calculated S5_MQB_INT_MAN_P
- Request
22 10 3C - Service 22
DID 103C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.
Intake manifold pressure raw value S5_INT_MANIFOLD_P_RAW
- Request
22 3E 70 - Service 22
DID 3E70 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 bar
- Unit
- bar
In testing for 2007 to 2026.
Intake manifold pressure, commanded S5_INT_MANIFOLD_P_CMD
- Request
22 11 DD - Service 22
DID 11DD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 5 ÷ 64)- Range
- 0 to 5119.9218
- Unit
- Raw value
In testing for 2007 to 2026.
Intake manifold pressure, corrected S5_INT_MANIFOLD_P
- Request
22 11 DA - Service 22
DID 11DA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 5 ÷ 64)- Range
- 0 to 5119.9218
- Unit
- Raw value
In testing for 2007 to 2026.
Intake manifold runner control, acknowledgment S5_INT_MANIFOLD_RUNNER_CTRL
- Request
22 20 6A - Service 22
DID 206A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Intake manifold runner control, activation S5_INT_MANIFOLD_RUNNER
- Request
22 20 69 - Service 22
DID 2069 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Intake model air mass flow filtered value S5_INT_MODEL_AIR_MASS
- Request
22 11 AB - Service 22
DID 11AB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5
- Unit
- Raw value
In testing for 2007 to 2026.
Intake phase deviation, actual value S5_INT_PHASE_DEV_ACT
- Request
22 18 00 - Service 22
DID 1800 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047.9375 °
- Unit
- °
In testing for 2007 to 2026.
Integrated mass of air since engine start S5_INTEGRATED_MASS_AIR
- Request
22 11 75 - Service 22
DID 1175 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 8889 ÷ 25000)- Range
- 0 to 23301.6246
- Unit
- Raw value
In testing for 2007 to 2026.
Integrated mass of air since the first engine start S5_INTEGRATED_MASS_AIR_SINCE
- Request
22 17 43 - Service 22
DID 1743 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 8889 ÷ 25000)- Range
- 0 to 23301.6246
- Unit
- Raw value
In testing for 2007 to 2026.
Intercooler air output temperature S5_PQ35_INTERCOOLER_AIR_OUTPUT_T
- Request
22 16 28 - Service 22
DID 1628 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2007 to 2026.
Kick down S5_MQB_TCM_KICK_DOWNConfirmed
- Request
22 21 14 - Service 22
DID 2114 - Module
7E1 → 7E9 - Every
1 s - Testing for 2007 to 2015, 2018 to 2026
Example reply from a 2017 Audi S5.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2016 to 2017. In testing for 2007 to 2015, 2018 to 2026.
Kilometers driven since last event on K1 S5_MQB_DQ250_KILOMETERS_DRIVEN_SINCE_LAST_EVENT_ON_K1Confirmed
- Request
22 11 5A - Service 22
DID 115A - Module
7E1 → 7E9 - Every
30 s - Testing for 2007 to 2015, 2017 to 2026
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 10)- Range
- 0 to 7000 km
- Unit
- km
Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.
Kilometers driven since last event on K2 S5_MQB_DQ250_KILOMETERS_DRIVEN_SINCE_LAST_EVENT_ON_K2Confirmed
- Request
22 11 5C - Service 22
DID 115C - Module
7E1 → 7E9 - Every
30 s - Testing for 2007 to 2015, 2017 to 2026
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 10)- Range
- 0 to 7000 km
- Unit
- km
Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.
Knock retard 4 S5_KNOCK_RETARD_4Confirmed
- Request
22 10 E7 - Service 22
DID 10E7 - Module
7E0 → 7E8 - Every
1 s - Testing for 2007 to 2023, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 7 of the reply, 8 bits. The value is signed.
0x00 = 0 → (0 × 3 ÷ 4) = 0 °
- Formula
(val × 3 ÷ 4)- Range
- -96 to 95.25 °
- Unit
- °
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Knock sensor 1 test S5_KNOCK_SENS_1_TEST
- Request
22 39 3C - Service 22
DID 393C - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2007 to 2026.
Knock sensor 2 test S5_KNOCK_SENS_2_TEST
- Request
22 39 3C - Service 22
DID 393C - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 1 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2007 to 2026.
Knock sensor 3 test S5_KNOCK_SENS_3_TEST
- Request
22 39 3C - Service 22
DID 393C - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2007 to 2026.
Knock sensor 4 test S5_KNOCK_SENS_4_TEST
- Request
22 39 3C - Service 22
DID 393C - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 3 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2007 to 2026.
Knock sensor, cylinder 1 S5_KNOCK_SENS_CYL_1
- Request
22 39 60 - Service 22
DID 3960 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2007 to 2026.
Knock sensor, cylinder 1 S5_KNOCK_SNS_C1_V_MS
- Request
22 12 0E - Service 22
DID 120E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val × 0.0076294 ÷ 10000)- Range
- 0 to 3276
- Unit
- Number
In testing for 2007 to 2026.
Knock sensor, cylinder 2 S5_KNOCK_SENS_CYL_2
- Request
22 39 61 - Service 22
DID 3961 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2007 to 2026.
Knock sensor, cylinder 2 S5_KNOCK_SENS_CYL_2_7E0
- Request
22 12 12 - Service 22
DID 1212 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val × 7.62e-7)- Range
- 0 to 3272
- Unit
- Number
In testing for 2007 to 2026.
Knock sensor, cylinder 2 S5_KNOCK_SNS_C2_V_MS
- Request
22 12 11 - Service 22
DID 1211 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val × 0.0076294 ÷ 10000)- Range
- 0 to 3276
- Unit
- Number
In testing for 2007 to 2026.
Knock sensor, cylinder 3 S5_KNOCK_SENS_CYL_3
- Request
22 39 62 - Service 22
DID 3962 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2007 to 2026.
Knock sensor, cylinder 3 S5_KNOCK_SNS_C3_V_MS
- Request
22 12 0F - Service 22
DID 120F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val × 0.0076294 ÷ 10000)- Range
- 0 to 3276
- Unit
- Number
In testing for 2007 to 2026.
Knock sensor, cylinder 4 S5_KNOCK_SENS_CYL_4
- Request
22 39 63 - Service 22
DID 3963 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2007 to 2026.
Knock sensor, cylinder 4 S5_KNOCK_SNS_C4_V_MS
- Request
22 12 10 - Service 22
DID 1210 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val × 0.0076294 ÷ 10000)- Range
- 0 to 3276
- Unit
- Number
In testing for 2007 to 2026.
Lambda output value S5_LAMBDA_OUTPUT
- Request
22 15 D4 - Service 22
DID 15D4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 199997 ÷ 6553500000)- Range
- 0 to 1.99
- Unit
- Number
In testing for 2007 to 2026.
Lambda, actual value S5_LAMBDA_ACTConfirmed
- Request
22 10 D5 - Service 22
DID 10D5 - Module
7E0 → 7E8 - Every
1 s - Testing for 2007 to 2023, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0000 = 0 → (0 × 12207 ÷ 50000000) = 0
- Formula
(val × 12207 ÷ 50000000)- Range
- -7.9999 to 7.9997
- Unit
- Number
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Launch control counter, variant 1 S5_LAUNCH_CTRL_CNT_VAR_1
- Request
22 12 00 - Service 22
DID 1200 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Launch control counter, variant 2 S5_LAUNCH_CTRL_CNT_VAR_2
- Request
22 38 F1 - Service 22
DID 38F1 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Leg deflector temperature S5_CLIMATE_LEG_DEFL_T
- Request
22 26 11 - Service 22
DID 2611 - Module
746 → 7B0 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 3)- Range
- 0 to 84.915 °C
- Unit
- °C
In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.
Long term fuel trim at idle, direct injection S5_LONG_TERM_FUEL_TRIM_IDLE
- Request
22 17 7E - Service 22
DID 177E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 3 ÷ 64)- Range
- -1536 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Long term fuel trim at idle, port injection S5_LONG_TERM_FUEL_TRIM_IDLE_PORT_INJ
- Request
22 17 80 - Service 22
DID 1780 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 3 ÷ 64)- Range
- -1536 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Long-term adaptation of intake manifold injection S5_LONG_TERM_ADPT_INT
- Request
22 41 4E - Service 22
DID 414E - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327 %
- Unit
- %
In testing for 2007 to 2026.
Long-term adaptation of intake manifold injection at idle S5_LONG_TERM_ADPT_INT_MANIFOLD_INJ
- Request
22 41 4F - Service 22
DID 414F - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327
- Unit
- Raw value
In testing for 2007 to 2026.
Lost torque adaptation A/C + driving mode S5_LOST_TQ_ADPT_AC
- Request
22 43 7F - Service 22
DID 437F - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 N·m
- Unit
- N·m
In testing for 2007 to 2026.
Lost torque adaptation driving mode S5_LOST_TQ_ADPT_DRIVING
- Request
22 43 7E - Service 22
DID 437E - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 N·m
- Unit
- N·m
In testing for 2007 to 2026.
Lower adapted coupling point K2 from micro-slip path adaptation S5_MQB_DQ250_LOWER_ADAPTED_COUPLING_POINT_K2_FROM_MICRO_SLIP_PATH_ADAPTConfirmed
- Request
22 11 0A - Service 22
DID 110A - Module
7E1 → 7E9 - Every
3600 s - Testing for 2007 to 2016, 2018 to 2026
Example reply from a 2017 Audi S5.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → (0 × 5) = 0 mA
- Formula
(val × 5)- Range
- 0 to 1275 mA
- Unit
- mA
Confirmed for 2017. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016.
M009, desired solenoid out 10 S5_M009_DES_SOLENOID_10
- Request
22 10 2E - Service 22
DID 102E - Module
7E1 → 7E9 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2007 to 2026.
M009, desired solenoid out 11 S5_M009_DES_SOLENOID_11
- Request
22 10 2E - Service 22
DID 102E - Module
7E1 → 7E9 - Every
1 s - Testing
Bit 1 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2007 to 2026.
M009, desired solenoid out 12 S5_M009_DES_SOLENOID_12
- Request
22 10 2E - Service 22
DID 102E - Module
7E1 → 7E9 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2007 to 2026.
M009, desired solenoid out 13 S5_M009_DES_SOLENOID_13
- Request
22 10 2E - Service 22
DID 102E - Module
7E1 → 7E9 - Every
1 s - Testing
Bit 3 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2007 to 2026.
M009, desired solenoid out 14 S5_M009_DES_SOLENOID_14
- Request
22 10 2E - Service 22
DID 102E - Module
7E1 → 7E9 - Every
1 s - Testing
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2007 to 2026.
Main cat oxygen storage capacity age correction factor S5_MAIN_CAT_OSC_AGE_CORRECTION_FACTOR
- Request
22 14 F9 - Service 22
DID 14F9 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2 ÷ 65535)- Range
- 0 to 2
- Unit
- Number
In testing for 2007 to 2026.
Manifold absolute pressure, raw value S5_MAP_RAW
- Request
22 11 DC - Service 22
DID 11DC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 5 ÷ 64)- Range
- 0 to 5119.9218
- Unit
- Raw value
In testing for 2007 to 2026.
Manual engine starts counter S5_MANUAL_ENG_STARTS
- Request
22 29 98 - Service 22
DID 2998 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Mass air flow over throttle valve S5_MAF_OVER_THROTTLE
- Request
22 39 4F - Service 22
DID 394F - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2007 to 2026.
Mass air flow rate S5_MAF_RATE
- Request
22 13 CD - Service 22
DID 13CD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047
- Unit
- Raw value
In testing for 2007 to 2026.
Mass air flow through throttle S5_MAF_THROUGH_THROTTLE
- Request
22 11 AC - Service 22
DID 11AC - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5
- Unit
- Raw value
In testing for 2007 to 2026.
Mass air flow, commanded S5_MAF_CMD
- Request
22 11 AD - Service 22
DID 11AD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5
- Unit
- Raw value
In testing for 2007 to 2026.
Mass airflow sensor 1 bank 1 raw value S5_MQB_MAF_1_B1_RAWConfirmed
- Request
22 10 26 - Service 22
DID 1026 - Module
7E0 → 7E8 - Every
1 s - Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0000 = 0 → (0 × 1000 ÷ 10000) = 0
- Formula
(val × 1000 ÷ 10000)- Range
- -3276.8 to 3276.7
- Unit
- Raw value
Confirmed for 2017, 2024. In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016.
Mass flow through throttle valve S5_MASS_FLOW_THROUGH
- Request
22 11 0A - Service 22
DID 110A - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553
- Unit
- Raw value
In testing for 2007 to 2026.
Max permissible engine torque S5_MAX_PERMISSIBLE_ENG
- Request
22 21 1A - Service 22
DID 211A - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 N·m
- Unit
- N·m
In testing for 2007 to 2026.
Maximum ECU temperature S5_MAX_ECU_T
- Request
22 46 49 - Service 22
DID 4649 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2007 to 2026.
Maximum filling correction factor from knock control S5_MAX_FILLING_CORR
- Request
22 10 E9 - Service 22
DID 10E9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 3 ÷ 100000)- Range
- 0 to 1.96
- Unit
- Number
In testing for 2007 to 2026.
Maximum oil level for the service interval S5_MAX_OIL_LEVEL
- Request
22 12 30 - Service 22
DID 1230 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 mm
- Unit
- mm
In testing for 2007 to 2026.
Mean engine air mass S5_MEAN_ENG_AIR_MASS
- Request
22 20 32 - Service 22
DID 2032 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2007 to 2026.
Mean engine air mass S5_PQ35_MEAN_AIR_MASSConfirmed
- Request
22 13 14 - Service 22
DID 1314 - Module
7E0 → 7E8 - Every
1 s - Testing for 2007 to 2015, 2017 to 2026
Example reply from a 2016 Audi S5.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → (0 ÷ 32) = 0
- Formula
(val ÷ 32)- Range
- 0 to 2047.968
- Unit
- Raw value
Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.
Mean injection quantity S5_MEAN_INJ_QUANTITYConfirmed
- Request
22 11 39 - Service 22
DID 1139 - Module
7E0 → 7E8 - Every
1 s - Testing for 2007 to 2015, 2018 to 2023, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x3684 = 13956 → (13956 ÷ 100) = 139.56
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67
- Unit
- Raw value
Confirmed for 2016 to 2017, 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2023.
Mileage with ECU installed S5_MILEAGE_ECU
- Request
22 10 A2 - Service 22
DID 10A2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 4294967 km
- Unit
- km
In testing for 2007 to 2026.
Minimum oil level for the service interval S5_MIN_OIL_LEVEL
- Request
22 12 31 - Service 22
DID 1231 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 mm
- Unit
- mm
In testing for 2007 to 2026.
Misfires / 1000 revolutions, cylinder 1 S5_MISFIRES_1000REV_C1Confirmed
- Request
22 11 47 - Service 22
DID 1147 - Module
7E0 → 7E8 - Every
1 s - Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2017, 2024. In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016.
Misfires / 1000 revolutions, cylinder 2 S5_MISFIRES_1000REV_C2Confirmed
- Request
22 11 4A - Service 22
DID 114A - Module
7E0 → 7E8 - Every
1 s - Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2017, 2024. In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016.
Misfires counter:, cylinder 1 S5_MIS_CNT_1
- Request
22 14 7E - Service 22
DID 147E - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Misfires counter:, cylinder 2 S5_MIS_CNT_2
- Request
22 14 82 - Service 22
DID 1482 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Misfires counter:, cylinder 3 S5_MIS_CNT_3
- Request
22 14 80 - Service 22
DID 1480 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Misfires counter:, cylinder 4 S5_MIS_CNT_4
- Request
22 14 7F - Service 22
DID 147F - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Misfires counter:, cylinder 5 S5_MIS_CNT_5
- Request
22 14 83 - Service 22
DID 1483 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Misfires counter:, cylinder 6 S5_MIS_CNT_6
- Request
22 14 81 - Service 22
DID 1481 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Misfires per 1000 revolutions 2 S5_MIS_PER_1000_2_7E0_7E0Confirmed
- Request
22 11 4B - Service 22
DID 114B - Module
7E0 → 7E8 - Every
1 s - Testing for 2007 to 2023, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Misfires per 1000 revolutions 4 S5_MIS_PER_1000_4_7E0Confirmed
- Request
22 11 4C - Service 22
DID 114C - Module
7E0 → 7E8 - Every
1 s - Testing for 2007 to 2023, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Misfires per 1000 revolutions, cylinder 1, port injection S5_MIS_PER_1000_1
- Request
22 42 6B - Service 22
DID 426B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Misfires per 1000 revolutions, cylinder 2 S5_MIS_PER_1000_2_7E0
- Request
22 10 F6 - Service 22
DID 10F6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Misfires per 1000 revolutions, cylinder 2, port injection S5_MIS_PER_1000_2
- Request
22 42 6C - Service 22
DID 426C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Misfires per 1000 revolutions, cylinder 3 S5_MIS_PER_1000_3_7E0
- Request
22 10 F4 - Service 22
DID 10F4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Misfires per 1000 revolutions, cylinder 3, port injection S5_MIS_PER_1000_3
- Request
22 42 6D - Service 22
DID 426D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Misfires per 1000 revolutions, cylinder 4, port injection S5_MIS_PER_1000_4
- Request
22 42 6E - Service 22
DID 426E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Misfires total S5_MIS_TOT
- Request
22 29 04 - Service 22
DID 2904 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Misfires total S5_MISFIRES_TOTALConfirmed
- Request
22 11 46 - Service 22
DID 1146 - Module
7E0 → 7E8 - Every
1 s - Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2017, 2024. In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016.
Misfires, cylinder 1 S5_MIS_1
- Request
22 10 F7 - Service 22
DID 10F7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Misfires, cylinder 1 S5_MISFIRES_C1
- Request
22 29 66 - Service 22
DID 2966 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Misfires, cylinder 2 S5_MIS_2
- Request
22 10 FA - Service 22
DID 10FA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Misfires, cylinder 2 S5_MISFIRES_C2
- Request
22 29 69 - Service 22
DID 2969 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Misfires, cylinder 3 S5_MIS_3
- Request
22 10 F8 - Service 22
DID 10F8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Misfires, cylinder 3 S5_MISFIRES_C3
- Request
22 29 67 - Service 22
DID 2967 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Misfires, cylinder 3 S5_MISFIRES_C3_ECMConfirmed
- Request
22 11 50 - Service 22
DID 1150 - Module
7E0 → 7E8 - Every
1 s - Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 15 of the reply, 16 bits.
0x02F7 = 759 → 759
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2017, 2024. In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016.
Misfires, cylinder 4 S5_MIS_4
- Request
22 10 F5 - Service 22
DID 10F5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Misfires, cylinder 4 S5_MISFIRES_C4
- Request
22 29 68 - Service 22
DID 2968 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Mixture adaptation factor at partial load S5_MIXTURE_ADPT_FACTOR
- Request
22 39 96 - Service 22
DID 3996 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 100 %
- Unit
- %
In testing for 2007 to 2026.
N_32 S5_N_32
- Request
22 11 7D - Service 22
DID 117D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 32)- Range
- 0 to 8160 rpm
- Unit
- rpm
In testing for 2007 to 2026.
NL_PRE, 0 S5_NL_PRE_0
- Request
22 13 F6 - Service 22
DID 13F6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 38147 ÷ 500000000)- Range
- 0 to 4.9999 V
- Unit
- V
In testing for 2007 to 2026.
NL_PRE, 1 S5_NL_PRE_1
- Request
22 13 F7 - Service 22
DID 13F7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 38147 ÷ 500000000)- Range
- 0 to 4.9999 V
- Unit
- V
In testing for 2007 to 2026.
NL_PRE, 2 S5_NL_PRE_2
- Request
22 13 F8 - Service 22
DID 13F8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 38147 ÷ 500000000)- Range
- 0 to 4.9999 V
- Unit
- V
In testing for 2007 to 2026.
NL_PRE, 3 S5_NL_PRE_3
- Request
22 13 F9 - Service 22
DID 13F9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 38147 ÷ 500000000)- Range
- 0 to 4.9999 V
- Unit
- V
In testing for 2007 to 2026.
Number of injections S5_NUM_INJECTIONS
- Request
22 43 0E - Service 22
DID 430E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Number of times the permitted centrifugal oil temperature has been exceeded S5_NUM_TIMES_PERMITTED_T
- Request
22 11 54 - Service 22
DID 1154 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2026.
Number of warnings due to increased centrifugal oil temperature S5_NUM_WARN_HI_CENTRIF_T
- Request
22 11 55 - Service 22
DID 1155 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2026.
NV energy requirement S5_NV_ENERGY
- Request
22 15 12 - Service 22
DID 1512 - Module
710 → 77A - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val ÷ 20)- Range
- 0 to 12.75 kWh
- Unit
- kWh
In testing for 2007 to 2026.
Oil ash residue S5_PQ35_OIL_ASH_RESIDUEConfirmed
- Request
22 17 8C - Service 22
DID 178C - Module
7E0 → 7E8 - Every
1 s - Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → (0 ÷ 10) = 0
- Formula
(val ÷ 10)- Range
- 0 to 6553.5
- Unit
- Raw value
Confirmed for 2017, 2024. In testing for 2007 to 2016, 2018 to 2023, 2025 to 2026.
Oil dynamic average measurement S5_PQ35_OIL_DYN_AVG
- Request
22 12 3F - Service 22
DID 123F - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 mm
- Unit
- mm
In testing for 2007 to 2026.
Oil fill level S5_PQ35_OIL_FILL_LEVEL
- Request
22 20 06 - Service 22
DID 2006 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.06)- Range
- -1966.08 to 1966.02 mm
- Unit
- mm
In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.
Oil last dynamic measurement S5_PQ35_OIL_DYN_LAST
- Request
22 12 3C - Service 22
DID 123C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 mm
- Unit
- mm
In testing for 2007 to 2026.
Oil level S5_OIL_LEVELConfirmed
- Request
22 11 BA - Service 22
DID 11BA - Module
7E0 → 7E8 - Every
30 s - Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 15 of the reply, 16 bits.
0x23FE = 9214 → (9214 ÷ 2500) = 3.6856 cm
- Formula
(val ÷ 2500)- Range
- 0 to 26.2 cm
- Unit
- cm
Confirmed for 2017, 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016, 2023.
Oil level method 1 S5_OIL_LEVEL_METHOD_1
- Request
22 1A F9 - Service 22
DID 1AF9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 %
- Unit
- %
In testing for 2007 to 2026.
Oil level method 2 S5_OIL_LEVEL_METHOD_2
- Request
22 1A FA - Service 22
DID 1AFA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 %
- Unit
- %
In testing for 2007 to 2026.
Oil level method 3 S5_OIL_LEVEL_METHOD_3
- Request
22 1A FB - Service 22
DID 1AFB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 %
- Unit
- %
In testing for 2007 to 2026.
Oil level test method 1 S5_OIL_LEVEL_TEST_1
- Request
22 4E 51 - Service 22
DID 4E51 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Oil level test method 2 S5_OIL_LEVEL_TEST_2
- Request
22 4E 52 - Service 22
DID 4E52 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Oil level test method 3 S5_OIL_LEVEL_TEST_3
- Request
22 4E 53 - Service 22
DID 4E53 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Oil level, average dynamic value S5_OIL_LEVEL_AVG
- Request
22 15 B9 - Service 22
DID 15B9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 mm
- Unit
- mm
In testing for 2007 to 2026.
Oil level, static measured S5_OIL_LEVEL_STATIC
- Request
22 15 A4 - Service 22
DID 15A4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 mm
- Unit
- mm
In testing for 2007 to 2026.
Oil level, static measurement S5_OIL_LEVEL_STATIC_7E0
- Request
22 40 CE - Service 22
DID 40CE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 127)- Range
- -127 to 3968 mm
- Unit
- mm
In testing for 2007 to 2026.
Oil p S5_OIL_P
- Request
22 25 CD - Service 22
DID 25CD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 kPa
- Unit
- kPa
In testing for 2007 to 2026.
Oil pressure actual S5_MQB_TCM_EOP_ACTUAL
- Request
22 38 1D - Service 22
DID 381D - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 100 ÷ 10000)- Range
- 0 to 655.35 bar
- Unit
- bar
In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.
Oil pressure actual current S5_MQB_TCM_EOP_ACTUAL_I
- Request
22 38 1E - Service 22
DID 381E - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 mA
- Unit
- mA
In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.
Oil pressure control valve activation pulse duty factor S5_OIL_P_CTRL_VLV
- Request
22 25 D0 - Service 22
DID 25D0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327 %
- Unit
- %
In testing for 2007 to 2026.
Oil pressure control valve, activation pulse duty factor S5_OIL_P_CTRL_VLV_ACTIVATION
- Request
22 4F 97 - Service 22
DID 4F97 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327 %
- Unit
- %
In testing for 2007 to 2026.
Oil pressure sensor raw value S5_OIL_P_SENS_RAW
- Request
22 4F BE - Service 22
DID 4FBE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Number
In testing for 2007 to 2026.
Oil pressure sensor-piston cooling nozzle switch, status S5_OIL_P_SENS_PISTON
- Request
22 15 BD - Service 22
DID 15BD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2026.
Oil pressure sensor, raw value S5_OIL_P_SENS_RAW_7E0
- Request
22 1B 02 - Service 22
DID 1B02 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Oil pressure switch activation, high pressure S5_OIL_P_SWITCH_P
- Request
22 20 A2 - Service 22
DID 20A2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2026.
Oil pressure switch for high pressure, closed S5_OIL_P_SWITCH_HIGH_P
- Request
22 20 A3 - Service 22
DID 20A3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2007 to 2026.
Oil pressure switch for low pressure, closed S5_OIL_P_SWITCH_LOW_P
- Request
22 20 A3 - Service 22
DID 20A3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2007 to 2026.
Oil pressure switch for piston-cooling jets, closed S5_OIL_P_SWITCH_PISTON
- Request
22 42 70 - Service 22
DID 4270 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2026.
Oil pressure switch valve activation S5_OIL_P_SWITCH_VLV
- Request
22 13 B8 - Service 22
DID 13B8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2026.
Oil pressure target S5_OIL_P_TGT
- Request
22 4F 70 - Service 22
DID 4F70 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 kPa
- Unit
- kPa
In testing for 2007 to 2026.
Oil pressure target S5_OIL_P_TGT_7E0
- Request
22 25 CF - Service 22
DID 25CF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 kPa
- Unit
- kPa
In testing for 2007 to 2026.
Oil pressure valve for piston cooling nozzles, control switch button ratio S5_OIL_P_VLV_PISTON
- Request
22 2C D8 - Service 22
DID 2CD8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327 %
- Unit
- %
In testing for 2007 to 2026.
Oil pressure valve switch, control S5_OIL_P_VLV_SWITCH
- Request
22 11 B9 - Service 22
DID 11B9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2026.
Oil pressure, actual value S5_OIL_P_ACT_7E0
- Request
22 17 7D - Service 22
DID 177D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 kPa
- Unit
- kPa
In testing for 2007 to 2026.
Oil pressure, actual value S5_OIL_P_ACT_7E0_2
- Request
22 1B 04 - Service 22
DID 1B04 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2007 to 2026.
Oil pressure, actual value S5_OIL_P_ACT_7E0_2_7E0
- Request
22 38 1D - Service 22
DID 381D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 kPa
- Unit
- kPa
In testing for 2007 to 2026.
Oil temp 2 S5_PQ35_ENGINE_OIL_T_2
- Request
22 17 9C - Service 22
DID 179C - Module
7E0 → 7E8 - Every
5 s - Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Supported for 2017, 2024. Not supported for 2016.
Oil temperature S5_OIL_T
Pelican can show this parameter as the engine oil temperature.
- Request
22 10 A7 - Service 22
DID 10A7 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2007 to 2026.
Oil temperature S5_PQ35_OIL_T
Pelican can show this parameter as the engine oil temperature.
- Request
22 20 2F - Service 22
DID 202F - Module
714 → 77E - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 58)- Range
- -58 to 197 °C
- Unit
- °C
In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.
Oil temperature variant S5_PQ35_OIL_T_2Confirmed
- Request
22 11 BE - Service 22
DID 11BE - Module
7E0 → 7E8 - Every
5 s - Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → (0 ÷ 10 − 273.1) = -273.1 °C
- Formula
(val ÷ 10 − 273.1)- Range
- -273.1 to 6280.4 °C
- Unit
- °C
Confirmed for 2017, 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016, 2023.
Oil thermal wear S5_DASH_OIL_THERMAL_WEARConfirmed
- Request
22 22 4B - Service 22
DID 224B - Module
714 → 77E - Every
300 s - Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → 0 km
- Formula
val- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.
Oil warning threshold S5_OIL_WARN_THR
- Request
22 20 07 - Service 22
DID 2007 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 mm
- Unit
- mm
In testing for 2007 to 2026.
Open cam shaft angle at quantity control valve S5_OPEN_CAM_SHFT_ANG
- Request
22 10 EA - Service 22
DID 10EA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 2007 to 2026.
Outside temperature S5_OUTSIDE_T
- Request
22 22 0C - Service 22
DID 220C - Module
714 → 77E - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 50)- Range
- -50 to 77.5 °C
- Unit
- °C
In testing for 2007 to 2026.
Outside temperature, system calculated S5_OUTSIDE_T_SYSTEMConfirmed
- Request
22 26 0A - Service 22
DID 260A - Module
746 → 7B0 - Every
5 s - Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0049 = 73 → (73 ÷ 10) = 7.3 °C
- Formula
(val ÷ 10)- Range
- -3276.8 to 100 °C
- Unit
- °C
Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.
Overall energy balance S5_OVERALL_ENERGY
- Request
22 2A 17 - Service 22
DID 2A17 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 23 of the reply, 24 bits. The value is signed.
- Formula
(val × 21 ÷ 20)- Range
- -8808038 to 8808037 Ah
- Unit
- Ah
In testing for 2007 to 2026.
Oxygen control, adaptation value at part. load S5_OXYGEN_CTRL_ADPT
- Request
22 39 A9 - Service 22
DID 39A9 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327 %
- Unit
- %
In testing for 2007 to 2026.
Oxygen sensor 1 bank 1 ceramic temperature S5_OXYGEN_SNS_1_BANK_1_CERAMIC_T
- Request
22 12 90 - Service 22
DID 1290 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 234.37 ÷ 10000 − 273.15)- Range
- -273.15 to 1262.793 °C
- Unit
- °C
In testing for 2007 to 2026.
Oxygen sensor 1 bank 1 lambda value S5_PQ35_O2_SEN_1_LAMBDAConfirmed
- Request
22 11 3D - Service 22
DID 113D - Module
7E0 → 7E8 - Every
1 s - Testing for 2007 to 2015, 2017 to 2026
Example reply from a 2016 Audi S5.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0xF3B5 = -3147 → (-3147 ÷ 100) = -31.47
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67
- Unit
- Number
Confirmed for 2016. In testing for 2007 to 2015, 2017 to 2026.
Particle filter, field regeneration lock status S5_PARTICLE_FLT_FIELD_REGENConfirmed
- Request
22 11 C1 - Service 22
DID 11C1 - Module
7E0 → 7E8 - Every
1 s - Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2017, 2024. In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016.
Piston cooling nozzles, control S5_PISTON_COOLING
- Request
22 16 F4 - Service 22
DID 16F4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2026.
Piston-cooling jets, activation S5_PISTON_COOLING_JETS
- Request
22 42 86 - Service 22
DID 4286 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2026.
Port injection injections counter S5_PORT_INJ_INJECTIONS
- Request
22 42 68 - Service 22
DID 4268 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2007 to 2026.
Post-injection 1 start position S5_PQ35_POST_INJ_1_STARTConfirmed
- Request
22 11 F4 - Service 22
DID 11F4 - Module
7E0 → 7E8 - Every
1 s - Testing for 2007 to 2015, 2017 to 2026
Example reply from a 2016 Audi S5.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x6973 = 26995 → (26995 ÷ 50) = 539.9 °
- Formula
(val ÷ 50)- Range
- -655.36 to 655.34 °
- Unit
- °
Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2017, 2024.
Post-injection 3 activation duration S5_PQ35_POST_INJ_3_ACTIVATION_DURATIONConfirmed
- Request
22 14 CE - Service 22
DID 14CE - Module
7E0 → 7E8 - Every
1 s - Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x1EF1 = 7921 → (7921 × 0.4 ÷ 1000) = 3.1684 ms
- Formula
(val × 0.4 ÷ 1000)- Range
- -13.1072 to 13.1068 ms
- Unit
- ms
Confirmed for 2017, 2024. In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016.
Post-injection 3 start position S5_PQ35_POST_INJ_3_STARTConfirmed
- Request
22 11 31 - Service 22
DID 1131 - Module
7E0 → 7E8 - Every
1 s - Testing for 2007 to 2015, 2017 to 2026
Example reply from a 2016 Audi S5.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0xF6B3 = -2381 → (-2381 ÷ 50) = -47.62 °
- Formula
(val ÷ 50)- Range
- -655.36 to 655.34 °
- Unit
- °
Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2017, 2024.
Pre-injection 2 duration S5_PQ35_PRE_INJ_2_DURATIONConfirmed
- Request
22 14 D1 - Service 22
DID 14D1 - Module
7E0 → 7E8 - Every
1 s - Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0xFFFE = -2 → (-2 × 0.4 ÷ 1000) = -0.0008 ms
- Formula
(val × 0.4 ÷ 1000)- Range
- -13.1072 to 13.1068 ms
- Unit
- ms
Confirmed for 2017, 2024. In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016.
Pressure before throttle valve - actual value S5_P_BEFORE_THROTTLE_ACT
- Request
22 11 EE - Service 22
DID 11EE - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 5 ÷ 64)- Range
- 0 to 5119.9218
- Unit
- Raw value
In testing for 2007 to 2026.
Pressure before throttle valve - sensor measured S5_P_BEFORE_THROTTLE
- Request
22 11 EF - Service 22
DID 11EF - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 21333 ÷ 546125)- Range
- 0 to 2559.96
- Unit
- Raw value
In testing for 2007 to 2026.
Pressure sensor 1 temperature S5_MQB_DL382_P_SENSOR_1_T
- Request
22 13 2A - Service 22
DID 132A - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.
Pressure sensor 2 temperature S5_MQB_DL382_P_SENSOR_2_T
- Request
22 13 2B - Service 22
DID 132B - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.
Pressure supply actual pressure S5_MQB_DQ200_P_SUPPLY_ACTUAL_PConfirmed
- Request
22 11 91 - Service 22
DID 1191 - Module
7E1 → 7E9 - Every
1 s - Testing for 2007 to 2015, 2017 to 2026
Example reply from a 2016 Audi S5.
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
0xC803 = -14333 → (-14333 ÷ 100) = -143.33 bar
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 bar
- Unit
- bar
Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.
Pressure supply actual pressure analog digital value S5_MQB_DQ200_P_SUPPLY_ACTUAL_P_AD_VALUE
- Request
22 10 2D - Service 22
DID 102D - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.
PSN_EDGE_REL_AD_CAM_SAVE_EX_1 S5_PSN_EDGE_REL_AD_CAM_1
- Request
22 11 84 - Service 22
DID 1184 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047.9375 °
- Unit
- °
In testing for 2007 to 2026.
PSN_EDGE_REL_AD_CAM_SAVE_EX_2 S5_PSN_EDGE_REL_AD_CAM_2
- Request
22 11 85 - Service 22
DID 1185 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047.9375 °
- Unit
- °
In testing for 2007 to 2026.
PSN_EDGE_REL_AD_CAM_SAVE_IN_1 S5_PSN_EDGE_REL_AD_CAM_SAVE_1
- Request
22 11 86 - Service 22
DID 1186 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047.9375 °
- Unit
- °
In testing for 2007 to 2026.
Radiator fan 1, commanded duty S5_RADIATOR_FAN_1_CMD
- Request
22 10 9E - Service 22
DID 109E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327 %
- Unit
- %
In testing for 2007 to 2026.
Radiator fan 2, commanded duty S5_RADIATOR_FAN_2_CMD
- Request
22 10 9C - Service 22
DID 109C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327 %
- Unit
- %
In testing for 2007 to 2026.
Radiator fan actual duty S5_CLIMATE_RAD_FAN_ACT_DUTYConfirmed
- Request
22 26 06 - Service 22
DID 2606 - Module
746 → 7B0 - Every
2 s - Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → (0 ÷ 2.5) = 0 %
- Formula
(val ÷ 2.5)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.
Radiator fan commanded duty S5_CLIMATE_RAD_FAN_CMD_DUTYConfirmed
- Request
22 26 07 - Service 22
DID 2607 - Module
746 → 7B0 - Every
2 s - Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → (0 ÷ 2.5) = 0 %
- Formula
(val ÷ 2.5)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.
Radiator outlet coolant temperature commanded S5_PQ35_RAD_COOL_T_CMD
- Request
22 11 11 - Service 22
DID 1111 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016 to 2017, 2024.
Radiator output coolant temp: actual S5_PQ35_RADIATOR_OUTPUT_COOLANT_T_ACTUAL
- Request
22 16 26 - Service 22
DID 1626 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016 to 2017, 2024.
Rated drive torque S5_RATED_DRIVE_TQ
- Request
22 14 A1 - Service 22
DID 14A1 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -214748364 to 214748364 N·m
- Unit
- N·m
In testing for 2007 to 2026.
Reached maximum temperature S5_PQ35_REACHED_MAXIMUM_TConfirmed
- Request
22 11 17 - Service 22
DID 1117 - Module
7E1 → 7E9 - Every
3600 s - Testing for 2007 to 2016, 2018 to 2026
Example reply from a 2017 Audi S5.
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
0x0000 = 0 → 0 °C
- Formula
val- Range
- -32768 to 32767 °C
- Unit
- °C
Confirmed for 2017. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016.
Rear cat converter temperature, main catalytic converter model value S5_REAR_CAT_CONV_T_MAIN_CAT_CONV_MODEL_VALUE
- Request
22 12 72 - Service 22
DID 1272 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1)- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2007 to 2026.
Rear deflector temperature S5_CLIMATE_RR_DEFL_TConfirmed
- Request
22 26 3D - Service 22
DID 263D - Module
746 → 7B0 - Every
5 s - Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → (0 ÷ 3) = 0 °C
- Formula
(val ÷ 3)- Range
- 0 to 84.915 °C
- Unit
- °C
Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.
Reducing agent tank volume, act. value filtered S5_REDUCING_AGENT_TANK_ACT
- Request
22 1A 6C - Service 22
DID 1A6C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 500)- Range
- 0 to 131 L
- Unit
- L
In testing for 2007 to 2026.
Refrigerant pressure S5_CLIMATE_REFRIG_PConfirmed
- Request
22 26 05 - Service 22
DID 2605 - Module
746 → 7B0 - Every
5 s - Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → (0 ÷ 5) = 0 bar
- Formula
(val ÷ 5)- Range
- 0 to 51 bar
- Unit
- bar
Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.
Regulation factor total S5_PQ35_REG_FACTOR
- Request
22 10 E4 - Service 22
DID 10E4 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10000)- Range
- 0 to 3.276 %
- Unit
- %
In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016 to 2017, 2024.
Relative load value S5_REL_LOAD
- Request
22 12 16 - Service 22
DID 1216 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0234403081)- Range
- 0 to 1536.1605
- Unit
- Number
In testing for 2007 to 2026.
Relay for reserve coolant pump status S5_RELAY_RESERVE_CLT
- Request
22 39 99 - Service 22
DID 3999 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2026.
Requested torque, amount for auxiliary units S5_REQ_TQ_AMOUNT
- Request
22 10 BE - Service 22
DID 10BE - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2007 to 2026.
Reserve torque S5_RESERVE_TQ
- Request
22 10 6A - Service 22
DID 106A - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 N·m
- Unit
- N·m
In testing for 2007 to 2026.
Result of crankcase ventilation test, fail S5_RESULT_CRANKCASE_VENTILATION_TEST
- Request
22 15 CC - Service 22
DID 15CC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Result of crankcase ventilation test, successful S5_RESULT_CRANKCASE
- Request
22 15 CB - Service 22
DID 15CB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Route data, active S5_ROUTE_DATA_ACTIVE
- Request
22 28 2C - Service 22
DID 282C - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2026.
Secondary air injection sensor 1 S5_SECONDARY_AIR_INJ_1
- Request
22 3F 68 - Service 22
DID 3F68 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 bar
- Unit
- bar
In testing for 2007 to 2026.
SEG_AD_MMV_ER_H, 0 S5_SEG_AD_MMV_ER_H_0
- Request
22 11 38 - Service 22
DID 1138 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 78123 ÷ 327670000)- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2007 to 2026.
SEG_AD_MMV_ER_H, 2 S5_SEG_AD_MMV_ER_H_2
- Request
22 11 3A - Service 22
DID 113A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 78123 ÷ 327670000)- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2007 to 2026.
SEG_AD_MMV_ER_H, 3 S5_SEG_AD_MMV_ER_H_3
- Request
22 11 3B - Service 22
DID 113B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 78123 ÷ 327670000)- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2007 to 2026.
SEG_AD_MMV_ER_L, 0 S5_SEG_AD_MMV_ER_L_0
- Request
22 11 3E - Service 22
DID 113E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 78123 ÷ 327670000)- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2007 to 2026.
SEG_AD_MMV_ER_L, 2 S5_SEG_AD_MMV_ER_L_2
- Request
22 11 40 - Service 22
DID 1140 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 78123 ÷ 327670000)- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2007 to 2026.
SEG_AD_MMV_ER_L, 3 S5_SEG_AD_MMV_ER_L_3
- Request
22 11 41 - Service 22
DID 1141 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 78123 ÷ 327670000)- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2007 to 2026.
SEG_AD_MMV_ER_MID, 0 S5_SEG_AD_MMV_ER_MID_0
- Request
22 11 32 - Service 22
DID 1132 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 78123 ÷ 327670000)- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2007 to 2026.
SEG_AD_MMV_ER_MID, 1 S5_SEG_AD_MMV_ER_MID_1
- Request
22 11 33 - Service 22
DID 1133 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 78123 ÷ 327670000)- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2007 to 2026.
SEG_AD_MMV_ER_MID, 2 S5_SEG_AD_MMV_ER_MID_2
- Request
22 11 34 - Service 22
DID 1134 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 78123 ÷ 327670000)- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2007 to 2026.
SEG_AD_MMV_ER, 1 S5_SEG_AD_MMV_ER_1
- Request
22 11 2D - Service 22
DID 112D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 78123 ÷ 327670000)- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2007 to 2026.
SEG_AD_MMV_ER, 2 S5_SEG_AD_MMV_ER_2
- Request
22 11 2E - Service 22
DID 112E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 78123 ÷ 327670000)- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2007 to 2026.
SEG_AD_MMV_ER, 3 S5_SEG_AD_MMV_ER_3
- Request
22 11 2F - Service 22
DID 112F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 78123 ÷ 327670000)- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2007 to 2026.
Service limit S5_SERVICE_LIM
- Request
22 20 DA - Service 22
DID 20DA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67
- Unit
- Raw value
In testing for 2007 to 2026.
Service limit S5_SERVICE_LIM_7E0
- Request
22 58 51 - Service 22
DID 5851 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67
- Unit
- Raw value
In testing for 2007 to 2026.
Service limit value S5_PQ35_SRV_LIM
- Request
22 12 CB - Service 22
DID 12CB - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35
- Unit
- Raw value
In testing for 2007 to 2026.
Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed
Correction being used by the closed-loop fuel algorithm.
Pelican can show this parameter as the short term fuel trim.
- Request
01 06 - Service 01
PID 06 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2017, 2024. Supported for 2016, 2018.
SIM card, SIM card in main unit S5_SIM_CARD_SIM_CARD
- Request
22 18 14 - Service 22
DID 1814 - Module
773 → 7DD - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2026.
Spark efficiency deviation at idle, maximum S5_SPARK_EFFICIENCY_DEV_MAX
- Request
22 15 5B - Service 22
DID 155B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Spark efficiency deviation at part load, maximum S5_SPARK_EFFICIENCY_DEV_PART_MAX
- Request
22 15 5C - Service 22
DID 155C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Stop signal switch S5_MQB_TCM_STOP_SIGNAL_SWITCH
- Request
22 38 00 - Service 22
DID 3800 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.
Sum of misfires counter S5_SUM_MIS_CNT
- Request
22 10 F2 - Service 22
DID 10F2 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Tank fill level diagnostic reference value S5_TANK_FILL_LEVEL
- Request
22 51 D8 - Service 22
DID 51D8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 L
- Unit
- L
In testing for 2007 to 2026.
TCO_1_ST S5_TCO_1_ST
- Request
22 11 D0 - Service 22
DID 11D0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2007 to 2026.
TCO_1_SYS S5_TCO_1_SYS
- Request
22 11 CD - Service 22
DID 11CD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2007 to 2026.
Temperature after evaporator S5_CLIMATE_T_AFTER_EVAPConfirmed
- Request
22 26 12 - Service 22
DID 2612 - Module
746 → 7B0 - Every
5 s - Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 7 of the reply, 8 bits. The value is signed.
0x00 = 0 → (0 ÷ 3) = 0 °C
- Formula
(val ÷ 3)- Range
- -42.624 to 42.291 °C
- Unit
- °C
Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.
Temperature at air conditioner heat exchanger output S5_T_AC_HEAT_EXCHANGER
- Request
22 11 77 - Service 22
DID 1177 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2007 to 2026.
Temperature sensor 14 S5_T_SENS_14
- Request
22 1E BB - Service 22
DID 1EBB - Module
7E5 → 7ED - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511 °C
- Unit
- °C
In testing for 2007 to 2026.
Temperature sensor for engine temperature management S5_T_SENS_ENG_T
- Request
22 39 2A - Service 22
DID 392A - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2007 to 2026.
Temperature sensor for engine temperature management, target value S5_T_SENS_ENG_T_TGT
- Request
22 40 E2 - Service 22
DID 40E2 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2007 to 2026.
Test of catalytic converter status, canceled S5_TEST_CATALYTIC_CONV_STAT
- Request
22 29 27 - Service 22
DID 2927 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2026.
Test of catalytic converter, measured value S5_TEST_CATALYTIC_CONV
- Request
22 29 26 - Service 22
DID 2926 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535
- Unit
- Number
In testing for 2007 to 2026.
Thermostat, actual S5_THERMOSTAT_ACT
- Request
22 44 18 - Service 22
DID 4418 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 12207 ÷ 1000000)- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Thermostat, commanded S5_THERMOSTAT_CMD
- Request
22 44 17 - Service 22
DID 4417 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 12207 ÷ 1000000)- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Throttle regulator nominal value S5_THROTTLE_REGULATOR
- Request
22 16 C5 - Service 22
DID 16C5 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 128)- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Throttle valve adapter position S5_PQ35_THROT_VALVE_ADAPT
- Request
22 12 FC - Service 22
DID 12FC - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016 to 2017, 2024.
TI_1_MPI, 0 S5_TI_1_MPI_0
- Request
22 13 AC - Service 22
DID 13AC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2007 to 2026.
TI_1_MPI, 1 S5_TI_1_MPI_1
- Request
22 13 AD - Service 22
DID 13AD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2007 to 2026.
TI_1_MPI, 2 S5_TI_1_MPI_2
- Request
22 13 AE - Service 22
DID 13AE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2007 to 2026.
TI_1_MPI, 3 S5_TI_1_MPI_3
- Request
22 13 AF - Service 22
DID 13AF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2007 to 2026.
TI_MES4_PLS_1, 1 S5_TI_MES4_PLS_1_1
- Request
22 13 A1 - Service 22
DID 13A1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2007 to 2026.
TI_MES4_PLS_1, 2 S5_TI_MES4_PLS_1_2
- Request
22 13 A2 - Service 22
DID 13A2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2007 to 2026.
TI_MES4_PLS_1, 3 S5_TI_MES4_PLS_1_3
- Request
22 13 A3 - Service 22
DID 13A3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2007 to 2026.
TI_MES4_PLS_2, 0 S5_TI_MES4_PLS_2_0
- Request
22 13 A4 - Service 22
DID 13A4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2007 to 2026.
TI_MES4_PLS_2, 1 S5_TI_MES4_PLS_2_1
- Request
22 13 A5 - Service 22
DID 13A5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2007 to 2026.
TI_MES4_PLS_2, 2 S5_TI_MES4_PLS_2_2
- Request
22 13 A6 - Service 22
DID 13A6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2007 to 2026.
TI_MES4_PLS_2, 3 S5_TI_MES4_PLS_2_3
- Request
22 13 A7 - Service 22
DID 13A7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2007 to 2026.
TI_MES4_PLS_3, 0 S5_TI_MES4_PLS_3_0
- Request
22 13 A8 - Service 22
DID 13A8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2007 to 2026.
TI_MES4_PLS_3, 1 S5_TI_MES4_PLS_3_1
- Request
22 13 A9 - Service 22
DID 13A9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2007 to 2026.
TI_MES4_PLS_3, 2 S5_TI_MES4_PLS_3_2
- Request
22 13 AA - Service 22
DID 13AA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2007 to 2026.
TI_MES4_PLS_3, 3 S5_TI_MES4_PLS_3_3
- Request
22 13 AB - Service 22
DID 13AB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2007 to 2026.
Time in after-run S5_TIME_AFTERRUN
- Request
22 10 3A - Service 22
DID 103A - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 s
- Unit
- s
In testing for 2007 to 2026.
Time since reset S5_TIME_SINCE_RESET
- Request
22 10 3B - Service 22
DID 103B - Module
7E1 → 7E9 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 30)- Range
- 0 to 7650 ms
- Unit
- ms
In testing for 2007 to 2026.
Timing angle retardation cylinder 1 S5_PQ35_TIMING_ANGLE_RETARDATION_CYL_1
- Request
22 20 0A - Service 22
DID 200A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 0.375 − 48)- Range
- -48 to 47.625 °
- Unit
- °
In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.
Timing angle retardation cylinder 2 S5_PQ35_TIMING_ANGLE_RETARDATION_CYL_2
- Request
22 20 0B - Service 22
DID 200B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 0.375 − 48)- Range
- -48 to 47.625 °
- Unit
- °
In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.
Timing angle retardation cylinder 3 S5_PQ35_TIMING_ANGLE_RETARDATION_CYL_3
- Request
22 20 0C - Service 22
DID 200C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 0.375 − 48)- Range
- -48 to 47.625 °
- Unit
- °
In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.
Timing angle retardation cylinder 4 S5_PQ35_TIMING_ANGLE_RETARDATION_CYL_4
- Request
22 20 0D - Service 22
DID 200D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 0.375 − 48)- Range
- -48 to 47.625 °
- Unit
- °
In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.
Timing deviation after chain replacement, exhaust bank 1 S5_TIM_DEV_AFTER_CHAIN_REPLACEMENT_1
- Request
22 41 7D - Service 22
DID 417D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 °
- Unit
- °
In testing for 2007 to 2026.
Timing deviation after chain replacement, intake bank 1 S5_TIM_DEV_AFTER_CHAIN_1
- Request
22 41 7B - Service 22
DID 417B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 °
- Unit
- °
In testing for 2007 to 2026.
Timing deviation after other repairs, intake bank 1 S5_TIM_DEV_AFTER_OTHER_1
- Request
22 41 7F - Service 22
DID 417F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 °
- Unit
- °
In testing for 2007 to 2026.
Timing deviation after other repairs, intake bank 1 S5_TIM_DEV_AFTER_OTHER_REPAIRS_INT_1
- Request
22 41 81 - Service 22
DID 4181 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 °
- Unit
- °
In testing for 2007 to 2026.
Timing deviation current value exhaust bank 1 S5_TIM_DEV_CURRENT_EXH_1
- Request
22 41 85 - Service 22
DID 4185 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 °
- Unit
- °
In testing for 2007 to 2026.
Timing deviation current value intake bank 1 S5_TIM_DEV_CURRENT_INT_1
- Request
22 41 83 - Service 22
DID 4183 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 °
- Unit
- °
In testing for 2007 to 2026.
Torque converter: torque loss S5_TORQUE_CONVERTER_TORQUE_LOSS
- Request
22 70 53 - Service 22
DID 7053 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 N·m
- Unit
- N·m
In testing for 2007 to 2026.
Torque factor S5_TQ_FACTOR
- Request
22 21 19 - Service 22
DID 2119 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2026.
Torque increase request from ESP S5_TQ_INCREASE_REQ_ESP
- Request
22 13 40 - Service 22
DID 1340 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -214748364 to 214748364 N·m
- Unit
- N·m
In testing for 2007 to 2026.
Torque limit S5_PQ35_LIM_TRQ
- Request
22 10 6B - Service 22
DID 106B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016 to 2017, 2024.
Torque limitation S5_TORQUE_LIMITATION
- Request
22 20 3F - Service 22
DID 203F - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 2007 to 2026.
Torque limitation S5_TQ_LIM
- Request
22 10 7D - Service 22
DID 107D - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 N·m
- Unit
- N·m
In testing for 2007 to 2026.
Torque limitation S5_TQ_LIM_7E0
- Request
22 20 3F - Service 22
DID 203F - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 N·m
- Unit
- N·m
In testing for 2007 to 2026.
Torque limitation, clutch protection S5_TQ_LIM_CLU
- Request
22 20 A0 - Service 22
DID 20A0 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 N·m
- Unit
- N·m
In testing for 2007 to 2026.
Torque loss adaptation S5_TQ_LOSS_ADPT
- Request
22 21 22 - Service 22
DID 2122 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2007 to 2026.
Torque loss adaptation at idle S5_TQ_LOSS_ADPT_IDLE
- Request
22 12 25 - Service 22
DID 1225 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2007 to 2026.
Torque loss adaptation, A/C compressor S5_TQ_LOSS_ADPT_AC_COMP_7E0
- Request
22 12 23 - Service 22
DID 1223 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2007 to 2026.
Torque reduction due to exhaust temperature S5_PQ35_TRQ_RED_EXH_T
- Request
22 10 E3 - Service 22
DID 10E3 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10000)- Range
- -3.2768 to 3.276
- Unit
- Number
In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016 to 2017, 2024.
Torque reduction request from ESP S5_TQ_REDUCTION_REQ_ESP
- Request
22 13 3F - Service 22
DID 133F - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -214748364 to 214748364 N·m
- Unit
- N·m
In testing for 2007 to 2026.
Torque request, sum of auxiliary aggregate S5_TQ_REQ_SUM_AUXILIARY
- Request
22 20 9B - Service 22
DID 209B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 N·m
- Unit
- N·m
In testing for 2007 to 2026.
Torque transmitting function, ratio S5_TQ_TRANSMITTING
- Request
22 21 05 - Service 22
DID 2105 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553
- Unit
- Number
In testing for 2007 to 2026.
Total mass of gasoline and ethyl alcohol in oil S5_TOT_MASS_GASOLINE
- Request
22 17 13 - Service 22
DID 1713 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.021333)- Range
- 0 to 1398.0581
- Unit
- Raw value
In testing for 2007 to 2026.
Transmission drag torque S5_TCM_DRAG_TQ
- Request
22 10 21 - Service 22
DID 1021 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 N·m
- Unit
- N·m
In testing for 2007 to 2026.
Transmission fluid temperature, calculated S5_ATF_T_CALCULATED
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 70 4E - Service 22
DID 704E - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2007 to 2026.
Transmission fluid temperature, modeled maximum reached S5_ATF_T_MODELED_MAX_REACHED
- Request
22 70 51 - Service 22
DID 7051 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 55)- Range
- -55 to 200 °C
- Unit
- °C
In testing for 2007 to 2026.
Transmission torque losses S5_TCM_TQ_LOSSES
- Request
22 10 22 - Service 22
DID 1022 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 N·m
- Unit
- N·m
In testing for 2007 to 2026.
Turbine actuator 1 bank 1 activation S5_PQ35_TURB_ACT_1_B1Confirmed
- Request
22 11 7E - Service 22
DID 117E - Module
7E0 → 7E8 - Every
1 s - Testing for 2007 to 2015, 2017 to 2026
Example reply from a 2016 Audi S5.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x059E = 1438 → (1438 ÷ 100) = 14.38 %
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2017.
Turbine actuator 1 bank 1: activation S5_ACTConfirmed
- Request
22 11 2C - Service 22
DID 112C - Module
7E0 → 7E8 - Every
1 s - Testing for 2007 to 2015, 2017 to 2026
Example reply from a 2016 Audi S5.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0000 = 0 → (0 ÷ 100) = 0 %
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2016. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2017, 2023 to 2024.
Upper adapted coupling point K1 from macro slip path adaptation S5_MQB_DQ250_UPPER_ADAPTED_COUPLING_POINT_K1_FROM_MACRO_SLIP_PATH_ADAPTConfirmed
- Request
22 11 0B - Service 22
DID 110B - Module
7E1 → 7E9 - Every
3600 s - Testing for 2007 to 2016, 2018 to 2026
Example reply from a 2017 Audi S5.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → (0 × 5) = 0 mA
- Formula
(val × 5)- Range
- 0 to 1275 mA
- Unit
- mA
Confirmed for 2017. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016.
Upper adapted coupling point K2 from macro slip path adaptation S5_MQB_DQ250_UPPER_ADAPTED_COUPLING_POINT_K2_FROM_MACRO_SLIP_PATH_ADAPTConfirmed
- Request
22 11 0C - Service 22
DID 110C - Module
7E1 → 7E9 - Every
3600 s - Testing for 2007 to 2016, 2018 to 2026
Example reply from a 2017 Audi S5.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → (0 × 5) = 0 mA
- Formula
(val × 5)- Range
- 0 to 1275 mA
- Unit
- mA
Confirmed for 2017. In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016.
Valve lift system, result of last switch, intake S5_VLV_LIFT_SYSTEM
- Request
22 16 BE - Service 22
DID 16BE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2026.
Valve lift system, valve lift, exhaust S5_VLV_LIFT_SYSTEM_VLV_LIFT
- Request
22 16 BB - Service 22
DID 16BB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2026.
Valve lift system, valve lift, intake S5_VLV_LIFT_SYSTEM_VLV
- Request
22 16 BA - Service 22
DID 16BA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2026.
Valve timing, the difference between the, actual and the set angle S5_VLV_TIM_DIFF_ACT_SET
- Request
22 10 EC - Service 22
DID 10EC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511.9843 °
- Unit
- °
In testing for 2007 to 2026.
Variable valve timing, intake, bank 1, regulation S5_VARIABLE_VLV_TIM_INT_1
- Request
22 12 7B - Service 22
DID 127B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0030517549)- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Variable valve timing, intake, bank 1, switch on S5_VARIABLE_VLV_TIM_INT_1_ON
- Request
22 12 7D - Service 22
DID 127D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0030517549)- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Wear index S5_PQ35_WEAR_IDX
- Request
22 10 E2 - Service 22
DID 10E2 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 m
- Unit
- m
In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016 to 2017, 2024.
Wear index %, 0=new engine S5_WEAR_INDEX_0_NEW_ENG
- Request
22 20 C2 - Service 22
DID 20C2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 20 ÷ 13107)- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Engine › DPF
Service regeneration status S5_PQ35_SRV_REGEN_STATConfirmed
- Request
22 11 5C - Service 22
DID 115C - Module
7E0 → 7E8 - Every
30 s - Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 7 of the reply, 8 bits.
0x27 = 39 → 39
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2017, 2024. In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016.
Soot mass calculated S5_PQ35_SOOT_MASS_CALCConfirmed
- Request
22 11 4F - Service 22
DID 114F - Module
7E0 → 7E8 - Every
1 s - Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 15 of the reply, 16 bits.
0x057F = 1407 → (1407 ÷ 100) = 14.07
- Formula
(val ÷ 100)- Range
- 0 to 655.35
- Unit
- Raw value
Confirmed for 2017, 2024. In testing for 2007 to 2016, 2018 to 2023, 2025 to 2026.
Engine › EGR
Exhaust gas recirculation 2: filter press loss, modeled S5_MQB_EXHAUST_GAS_RECIRCULATION_2_FILTER_P_LOSS_MODELED
- Request
22 2A E1 - Service 22
DID 2AE1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 500)- Range
- -3776.8 to 2776.7
- Unit
- Raw value
In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.
Exhaust gas recirculation 2: filter press loss, simulated S5_MQB_EXHAUST_GAS_RECIRCULATION_2_FILTER_P_LOSS_SIMULATED
- Request
22 2A E2 - Service 22
DID 2AE2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 500)- Range
- -3776.8 to 2776.7
- Unit
- Raw value
In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.
Engine › Internal
Boost pressure A control status supported BP_A_SUPSAE J1979Confirmed
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024.
Boost pressure A supported BP_A_ACT_SUPSAE J1979Confirmed
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024.
Boost pressure B control status supported BP_B_SUPSAE J1979Confirmed
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024.
Boost pressure B supported BP_B_ACT_SUPSAE J1979Confirmed
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 3 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024.
Commanded boost pressure A supported BP_A_CMD_SUPSAE J1979Confirmed
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024.
Commanded boost pressure B supported BP_B_CMD_SUPSAE J1979Confirmed
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024.
Engine › OxygenSensors
Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed
Pelican can show this parameter as the O2 lambda.
- Request
01 34 - Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32768)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2016 to 2017, 2024.
Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed
- Request
01 34 - Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 256 − 128)- Range
- -128 to 127.996 mA
- Unit
- mA
Confirmed for 2016 to 2017, 2024.