Climate parameters
The Audi S5 has 20 climate parameters.
● Confirmed◆ In testing○ Supported× Not supported
A/C compressor power, actual S5_AC_CMPR_PWR_ACT
- Request
22 08 00 - Service 22
DID 0800 - Module
746 → 7B0 - Every
5 s - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 W
- Unit
- W
In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.
A/C compressor torque, requested S5_AC_COMP_TConfirmed
- Request
22 10 02 - Service 22
DID 1002 - Module
7E0 → 7E8 - Every
250 ms - Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0000 = 0 → (0 ÷ 10) = 0 N·m
- Formula
(val ÷ 10)- Range
- -3276 to 3276 N·m
- Unit
- N·m
Confirmed for 2017, 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016, 2023.
A/C refrigerant pressure, sensor 1 S5_AC_REFRIG_P_SENS1
- Request
22 4E EF - Service 22
DID 4EEF - Module
746 → 7B0 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 88 ÷ 10000)- Range
- 0 to 576.708 bar
- Unit
- bar
In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.
A/C refrigerant temperature, sensor 1 S5_AC_REFRIG_T_SENS1
- Request
22 4E EF - Service 22
DID 4EEF - Module
746 → 7B0 - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 10 ÷ 100 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.
A/C refrigerant temperature, sensor 1 interior S5_AC_REFRIG_T_SENS1_INT
- Request
22 4E EF - Service 22
DID 4EEF - Module
746 → 7B0 - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val × 10 ÷ 100 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.
Air conditioning compressor power consumption S5_PQ35_AC_COMP_PWR
- Request
22 27 D6 - Service 22
DID 27D6 - Module
746 → 7B0 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val ÷ 25)- Range
- 0 to 10.2 kW
- Unit
- kW
In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016 to 2017, 2024.
Air conditioning compressor shutdown requirement S5_MQB_TCM_A_C_COMPRESSOR_SHUTDOWN_REQUIREMENT
- Request
22 38 1A - Service 22
DID 381A - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.
Air conditioning compressor torque S5_PQ35_AC_COMP_TRQ
- Request
22 10 4B - Service 22
DID 104B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016 to 2017, 2024.
Ambient air temperature S5_AAT_7E0_7E0
- Request
22 F4 46 - Service 22
DID F446 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2007 to 2026.
Ambient temperature S5_AAT_V2Confirmed
- Request
22 10 04 - Service 22
DID 1004 - Module
7E0 → 7E8 - Every
5 s - Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0000 = 0 → (0 ÷ 128) = 0 °C
- Formula
(val ÷ 128)- Range
- -255 to 255 °C
- Unit
- °C
Confirmed for 2017, 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016, 2023.
Barometric pressure S5_BARO
- Request
22 F4 33 - Service 22
DID F433 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 kPa
- Unit
- kPa
In testing for 2007 to 2026.
Cabin humidity S5_CABIN_HUMIDITY
- Request
22 27 C4 - Service 22
DID 27C4 - Module
746 → 7B0 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
CO2 content interior S5_CABIN_CO2
- Request
22 42 DB - Service 22
DID 42DB - Module
746 → 7B0 - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 100)- Range
- 0 to 25500
- Unit
- Number
In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.
Outside humidity S5_HVAC_OUTSIDE_HUM
- Request
22 27 C3 - Service 22
DID 27C3 - Module
746 → 7B0 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.
Outside temperature S5_AATConfirmed
- Request
22 26 09 - Service 22
DID 2609 - Module
746 → 7B0 - Every
5 s - Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026
Example reply from a 2024 Audi S5.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x003C = 60 → (60 ÷ 10) = 6 °C
- Formula
(val ÷ 10)- Range
- -3276.8 to 100 °C
- Unit
- °C
Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.
Recirculation flap actual position S5_MQB_RECIRC_FLAP_ACT
- Request
22 26 1E - Service 22
DID 261E - Module
746 → 7B0 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.
Recirculation flap fresh air threshold S5_MQB_RECIRC_FLAP_FRESH_THR
- Request
22 26 20 - Service 22
DID 2620 - Module
746 → 7B0 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.
Recirculation flap target position S5_MQB_RECIRC_FLAP_TRG
- Request
22 26 1F - Service 22
DID 261F - Module
746 → 7B0 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.
Recirculation flap threshold S5_MQB_RECIRC_FLAP_THR
- Request
22 26 21 - Service 22
DID 2621 - Module
746 → 7B0 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.
Windshield temperature S5_WINDSHIELD_T
- Request
22 27 C4 - Service 22
DID 27C4 - Module
746 → 7B0 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 0.576 − 38.8)- Range
- -38.8 to 108.08 °C
- Unit
- °C
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.