Ford Everest

Climate parameters

The Ford Everest has 7 climate parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

A/C refrigerant pressure EVEREST_PCM_A_C_REFRIG_PConfirmed

  • Request22 06 04
  • Service 22DID 0604
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2023, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x02BA = 698 → 698 kPa

Formula
val
Range
-32768 to 32767 kPa
Unit
kPa

Confirmed for 2024 to 2025. In testing for 2003 to 2023, 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

A/C compressor pressure EVEREST_AC_P

  • Request22 03 93
  • Service 22DID 0393
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 245251 ÷ 845473)
Range
0 to 1000 psi
Unit
psi

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

A/C compressor pressure sensor voltage EVEREST_AC_P_SENS_VConfirmed

  • Request22 98 00
  • Service 22DID 9800
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 1024)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

A/C compressor, state EVEREST_AC_STATE

  • Request22 09 9B
  • Service 22DID 099B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

A/C refrigerant pressure EVEREST_PCM_A_C_REFRIG_PConfirmed

  • Request22 06 04
  • Service 22DID 0604
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2023, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x02BA = 698 → 698 kPa

Formula
val
Range
-32768 to 32767 kPa
Unit
kPa

Confirmed for 2024 to 2025. In testing for 2003 to 2023, 2026.

Ambient air temperature AATSAE J1979Confirmed

  • Request01 46
  • Service 01PID 46
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2024.

Ambient temperature sensor voltage EVEREST_AAT_VConfirmed

  • Request22 03 BA
  • Service 22DID 03BA
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2023, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 5 ÷ 1023)
Range
0 to 5 V
Unit
V

Confirmed for 2024 to 2025. In testing for 2003 to 2023, 2026.

Ambient temperature, alternate EVEREST_AAT_ALT

  • Request22 05 7D
  • Service 22DID 057D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.