Ford Everest

Engine parameters

The Ford Everest has 205 engine parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Engine oil temperature, alternate EVEREST_EOT_F45CConfirmed

Pelican can show this parameter as the engine oil temperature.

  • Request22 F4 5C
  • Service 22DID F45C
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

0x34 = 52 → (52 − 40) = 12 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Absolute load value LOAD_ABSSAE J1979Confirmed

  • Request01 43
  • Service 01PID 43
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 25700 %
Unit
%

Confirmed for 2025.

Accelerator position EVEREST_ACC_POSConfirmed

  • Request22 03 2B
  • Service 22DID 032B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2003 to 2023, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → (0 ÷ 2) = 0 %

Formula
(val ÷ 2)
Range
0 to 100 %
Unit
%

Confirmed for 2024 to 2025. In testing for 2003 to 2023, 2026.

Actual EGR A duty cycle/position EGR_A_ACTSAE J1979Confirmed

  • Request01 69
  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 23 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2024.

Actual EGR B duty cycle/position EGR_B_ACTSAE J1979Confirmed

  • Request01 69
  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bits 40 to 47 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2024.

Actual engine percent torque EVEREST_PCM_ACT_ENG_PCT_TRQConfirmed

  • Request22 F4 62
  • Service 22DID F462
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

0x7D = 125 → (125 − 125) = 0 %

Formula
(val − 125)
Range
0 to 100 %
Unit
%

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Air conditioning pressure EVEREST_AC_P_7E0

  • Request22 FD 18
  • Service 22DID FD18
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 12.156863)
Range
0 to 3100 kPa
Unit
kPa

In testing for 2003 to 2026.

Air flow rate from mass air flow sensor MAFSAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Request01 10
  • Service 01PID 10
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 g/s
Unit
g/s

Confirmed for 2024.

Alternator 2 monitor EVEREST_ALTERNATOR_2_MON

  • Request22 04 55
  • Service 22DID 0455
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 100 ÷ 32767)
Range
0 to 200 %
Unit
%

In testing for 2003 to 2026.

Alternator current output EVEREST_ALTERNATOR_CURRENT

  • Request22 D1 13
  • Service 22DID D113
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 20)
Range
0 to 3276 A
Unit
A

In testing for 2003 to 2026.

Ambient air temperature EVEREST_AAT_7E0Confirmed

  • Request22 F4 46
  • Service 22DID F446
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

0x52 = 82 → (82 − 40) = 42 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2025. In testing for 2003 to 2024, 2026.

Barometric pressure EVEREST_BAROConfirmed

  • Request22 03 53
  • Service 22DID 0353
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits.

0x0178 = 376 → (376 × 615 ÷ 16963) = 13.632023 psi

Formula
(val × 615 ÷ 16963)
Range
8 to 20 psi
Unit
psi

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Barometric pressure EVEREST_BAROMETRIC_P

  • Request22 11 27
  • Service 22DID 1127
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 338639 ÷ 80000)
Range
0 to 1079.4118 kPa
Unit
kPa

In testing for 2003 to 2026.

Barometric pressure sensor voltage EVEREST_BARO_V

  • Request22 03 5A
  • Service 22DID 035A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 5 ÷ 1023)
Range
0 to 5 V
Unit
V

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Battery current EVEREST_BAT_CURRENT_726

  • Request22 40 90
  • Service 22DID 4090
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 511.7)
Range
-511.7 to 3584.2375 A
Unit
A

In testing for 2003 to 2026.

Boost EVEREST_BOOST

  • Request22 14 40
  • Service 22DID 1440
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 psi
Unit
psi

In testing for 2003 to 2026.

Boost pressure sensor A BP_A_ACTSAE J1979Confirmed

Actual turbocharger/supercharger A boost pressure.

  • Request01 70
  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 39 of the reply, 16 bits.

Formula
(val ÷ 32)
Range
0 to 2047.96875 kPa
Unit
kPa

Confirmed for 2024.

Boost pressure sensor B BP_B_ACTSAE J1979Confirmed

Actual turbocharger/supercharger B boost pressure.

  • Request01 70
  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 56 to 71 of the reply, 16 bits.

Formula
(val ÷ 32)
Range
0 to 2047.96875 kPa
Unit
kPa

Confirmed for 2024.

Bypass valve EVEREST_BPV_OPENConfirmed

  • Request22 04 27
  • Service 22DID 0427
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → (0 ÷ 255) = 0

Formula
(val ÷ 255)
Range
0 to 1
Unit
Number

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Request01 04
  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2024. Supported for 2025.

Camshaft position error, exhaust EVEREST_VCT_EXH_ERRConfirmed

  • Request22 03 1B
  • Service 22DID 031B
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits.

0x0005 = 5 → (5 ÷ 16) = 0.3125 °

Formula
(val ÷ 16)
Range
0 to 50 °
Unit
°

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Camshaft position error, intake EVEREST_VCT_INT_ERR

  • Request22 03 1A
  • Service 22DID 031A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16)
Range
-50 to 50 °
Unit
°

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Camshaft position, exhaust actual EVEREST_VCT_EXH_ACT

  • Request22 03 19
  • Service 22DID 0319
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16)
Range
0 to 50 °
Unit
°

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Camshaft position, exhaust desired EVEREST_VCT_EXH_DESConfirmed

  • Request22 03 BB
  • Service 22DID 03BB
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0000 = 0 → (0 ÷ 16) = 0 °

Formula
(val ÷ 16)
Range
-2047 to 2047 °
Unit
°

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Camshaft position, intake actual EVEREST_VCT_INT_ACTConfirmed

  • Request22 03 18
  • Service 22DID 0318
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0000 = 0 → (0 ÷ 16) = 0 °

Formula
(val ÷ 16)
Range
-2048 to 2047.93 °
Unit
°

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Camshaft position, intake desired EVEREST_VCT_INT_DES

  • Request22 03 BC
  • Service 22DID 03BC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16)
Range
-2047 to 2047 °
Unit
°

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Camshaft solenoid duty cycle, exhaust EVEREST_VCT_EXH_DUTY

  • Request22 03 17
  • Service 22DID 0317
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 25 ÷ 8192)
Range
0 to 100 %
Unit
%

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Camshaft solenoid duty cycle, intake EVEREST_VCT_INT_DUTY

  • Request22 03 16
  • Service 22DID 0316
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 25 ÷ 8192)
Range
0 to 100 %
Unit
%

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Catalyst temperature EVEREST_CAT_TEMP

  • Request22 F4 3C
  • Service 22DID F43C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Charge air temperature EVEREST_CAT

  • Request22 04 61
  • Service 22DID 0461
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 64 − 40)
Range
-40 to 189 °C
Unit
°C

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Charge air temperature sensor voltage EVEREST_CAT_SENS_V

  • Request22 04 60
  • Service 22DID 0460
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 1024)
Range
0 to 5 V
Unit
V

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Commanded boost pressure A BP_A_CMDSAE J1979Confirmed

Turbocharger/supercharger A commanded boost pressure.

  • Request01 70
  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 23 of the reply, 16 bits.

Formula
(val ÷ 32)
Range
0 to 2047.96875 kPa
Unit
kPa

Confirmed for 2024.

Commanded boost pressure B BP_B_CMDSAE J1979Confirmed

Turbocharger/supercharger B commanded boost pressure.

  • Request01 70
  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 40 to 55 of the reply, 16 bits.

Formula
(val ÷ 32)
Range
0 to 2047.96875 kPa
Unit
kPa

Confirmed for 2024.

Commanded EGR A duty cycle/position EGR_A_CMDSAE J1979Confirmed

  • Request01 69
  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2024.

Commanded EGR B duty cycle/position EGR_B_CMDSAE J1979Confirmed

  • Request01 69
  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2024.

Commanded generator duty EVEREST_CMD_GEN_DUTY

  • Request22 16 E8
  • Service 22DID 16E8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.003052)
Range
0 to 100 %
Unit
%

In testing for 2003 to 2026.

Coolant temperature EVEREST_ECTConfirmed

  • Request22 03 8F
  • Service 22DID 038F
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Ford Everest.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0424 = 1060 → (1060 ÷ 64) = 16.5625 °C

Formula
(val ÷ 64)
Range
-512 to 511 °C
Unit
°C

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Cylinder 1 misfire count EVEREST_MIS_CNT_1

  • Request22 16 0E
  • Service 22DID 160E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2026.

Cylinder 2 misfire count EVEREST_MIS_CNT_2

  • Request22 16 0F
  • Service 22DID 160F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2026.

Cylinder 3 misfire count EVEREST_MIS_CNT_3

  • Request22 16 10
  • Service 22DID 1610
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2026.

Cylinder 4 misfire count EVEREST_MIS_CNT_4

  • Request22 16 11
  • Service 22DID 1611
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2026.

Cylinder 5 misfire count EVEREST_MIS_CNT_5

  • Request22 16 12
  • Service 22DID 1612
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2026.

Cylinder 6 misfire count EVEREST_MIS_CNT_6

  • Request22 16 13
  • Service 22DID 1613
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2026.

Cylinder 7 misfire count EVEREST_MIS_CNT_7

  • Request22 16 14
  • Service 22DID 1614
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2026.

Cylinder 8 misfire count EVEREST_MIS_CNT_8

  • Request22 16 15
  • Service 22DID 1615
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2026.

Cylinder head temperature EVEREST_CYL_HEAD_T

  • Request22 05 1D
  • Service 22DID 051D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2003 to 2026.

Cylinder head temperature EVEREST_CYL_HEAD_T_7E0

  • Request22 16 24
  • Service 22DID 1624
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °F
Unit
°F

In testing for 2003 to 2026.

Cylinder head temperature EVEREST_PCM_CYL_HEAD_T_CORRConfirmed

  • Request22 03 34
  • Service 22DID 0334
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x168E = 5774 → (5774 ÷ 64) = 90.21875 °C

Formula
(val ÷ 64)
Range
-512 to 511 °C
Unit
°C

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Cylinder head temperature, alternate EVEREST_CYL_HEAD_T_ALT

  • Request22 16 85
  • Service 22DID 1685
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 281 ÷ 1000)
Range
0 to 18415 °F
Unit
°F

In testing for 2003 to 2026.

Cylinder head temperature, sensor 2 EVEREST_PCM_CYL_HEAD_T_SENS_2_RAWConfirmed

  • Request22 05 FC
  • Service 22DID 05FC
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Ford Everest.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x04DE = 1246 → (1246 ÷ 64) = 19.46875 °C

Formula
(val ÷ 64)
Range
-512 to 511 °C
Unit
°C

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Distance since DTC clear EVEREST_DIST_DTC_CLRConfirmed

  • Request22 F4 31
  • Service 22DID F431
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Ford Everest.

Bits 0 to 15 of the reply, 16 bits.

0x0033 = 51 → 51 km

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Distance with MIL EVEREST_MIL_DISTConfirmed

  • Request22 F4 21
  • Service 22DID F421
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2003 to 2023, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → 0 km

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2024 to 2025. In testing for 2003 to 2023, 2026.

DTC counter EVEREST_DTC_CNT

  • Request22 D1 37
  • Service 22DID D137
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2026.

EGR A error EGR_A_ERRSAE J1979Confirmed

  • Request01 69
  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 31 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.22 %
Unit
%

Confirmed for 2024.

EGR B error EGR_B_ERRSAE J1979Confirmed

  • Request01 69
  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bits 48 to 55 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.22 %
Unit
%

Confirmed for 2024.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Request01 05
  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2024. Supported for 2025.

Engine coolant temperature 1 ECT_1SAE J1979Confirmed

  • Request01 67
  • Service 01PID 67
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 15 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2024.

Engine coolant temperature 2 ECT_2SAE J1979Confirmed

  • Request01 67
  • Service 01PID 67
  • Module7E0 → 7E8
  • Every1 s

Bits 16 to 23 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2024.

Engine load EVEREST_ENG_LOAD_PCTConfirmed

  • Request22 F4 04
  • Service 22DID F404
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → (0 × 100 ÷ 255) = 0 %

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Engine load, actual EVEREST_ENG_LOAD_ACTConfirmed

  • Request22 F4 43
  • Service 22DID F443
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits.

0x0024 = 36 → (36 × 100 ÷ 255) = 14.117647 %

Formula
(val × 100 ÷ 255)
Range
0 to 25700 %
Unit
%

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Engine oil pressure - desired EVEREST_EOP_DES

  • Request22 05 EF
  • Service 22DID 05EF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 kPa
Unit
kPa

In testing for 2003 to 2026.

Engine oil temperature EOTSAE J1979Confirmed

Pelican can show this parameter as the engine oil temperature.

  • Request01 5C
  • Service 01PID 5C
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 210 °C
Unit
°C

Confirmed for 2024.

Engine oil temperature EVEREST_EOT

  • Request22 13 10
  • Service 22DID 1310
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100 − 40)
Range
-40 to 615 °C
Unit
°C

In testing for 2003 to 2026.

Engine oil temperature, alternate EVEREST_EOT_F45CConfirmed

Pelican can show this parameter as the engine oil temperature.

  • Request22 F4 5C
  • Service 22DID F45C
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

0x34 = 52 → (52 − 40) = 12 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Engine oil temperature, variant 2 EVEREST_EOT_VAR_2

  • Request22 13 13
  • Service 22DID 1313
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2003 to 2026.

Engine reference torque EVEREST_PCM_ENG_REFERENCE_TRQConfirmed

  • Request22 F4 63
  • Service 22DID F463
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2003 to 2023, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits.

0x01FC = 508 → 508 N·m

Formula
val
Range
0 to 65535 N·m
Unit
N·m

Confirmed for 2024 to 2025. In testing for 2003 to 2023, 2026.

Engine RPM RPMSAE J1979Confirmed

  • Request01 0C
  • Service 01PID 0C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383.75 rpm
Unit
rpm

Confirmed for 2024 to 2025.

Engine run time EVEREST_ERT

  • Request22 11 26
  • Service 22DID 1126
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 s
Unit
s

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Engine run time EVEREST_RUN_TIMEConfirmed

  • Request22 F4 1F
  • Service 22DID F41F
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2023, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits.

0x04AE = 1198 → 1,198 s

Formula
val
Range
0 to 65535 s
Unit
s

Confirmed for 2024 to 2025. In testing for 2003 to 2023, 2026.

Engine speed EVEREST_RPMConfirmed

  • Request22 F4 0C
  • Service 22DID F40C
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Ford Everest.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → (0 ÷ 4) = 0 rpm

Formula
(val ÷ 4)
Range
0 to 16383.75 rpm
Unit
rpm

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Evaporative pressure sensor voltage EVEREST_EVAP_V

  • Request22 03 8E
  • Service 22DID 038E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Evaporative purge EVEREST_EVAP_PURGE_CMDConfirmed

  • Request22 11 66
  • Service 22DID 1166
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits.

0x11F0 = 4592 → (4592 × 100 ÷ 32768) = 14.013672 %

Formula
(val × 100 ÷ 32768)
Range
0 to 100 %
Unit
%

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Exhaust back pressure EVEREST_EXH_BACK_P

  • Request22 14 45
  • Service 22DID 1445
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 29 ÷ 800)
Range
0 to 2375 psi
Unit
psi

In testing for 2003 to 2026.

Exhaust gas recirculation EVEREST_EGR

  • Request22 F4 2C
  • Service 22DID F42C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2003 to 2026.

Exhaust gas recirculation cooler inlet temperature EVEREST_EGR_COOLER_INLET_T

  • Request22 05 69
  • Service 22DID 0569
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 39 ÷ 1250)
Range
-1022 to 1022 °C
Unit
°C

In testing for 2003 to 2026.

Exhaust gas recirculation cooler outlet temperature EVEREST_EGR_COOLER_OUTLET_T

  • Request22 05 5D
  • Service 22DID 055D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 39 ÷ 1250)
Range
-1022 to 1022 °C
Unit
°C

In testing for 2003 to 2026.

Exhaust gas recirculation duty cycle EVEREST_EGR_DUTY

  • Request22 11 3C
  • Service 22DID 113C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2003 to 2026.

Exhaust gas recirculation inlet temperature EVEREST_EGR_INLET_T

  • Request22 11 61
  • Service 22DID 1161
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 9 ÷ 50 − 40)
Range
-40 to 11756 °F
Unit
°F

In testing for 2003 to 2026.

Exhaust gas recirculation open EVEREST_EGR_OPEN

  • Request22 05 2E
  • Service 22DID 052E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 2003 to 2026.

Exhaust gas recirculation temperature EVEREST_EGR_T

  • Request22 05 43
  • Service 22DID 0543
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2003 to 2026.

Exhaust gas recirculation temperature EVEREST_EGR_T_7E0_7E0

  • Request22 F4 6B
  • Service 22DID F46B
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 40)
Range
-40 to 6513 °C
Unit
°C

In testing for 2003 to 2026.

Exhaust gas recirculation temperature a EVEREST_EGR_T_115F

  • Request22 11 5F
  • Service 22DID 115F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 9 ÷ 50 − 40)
Range
-40 to 11756 °F
Unit
°F

In testing for 2003 to 2026.

Exhaust gas recirculation throttle position signal EVEREST_EGR_THROTTLE_POS_SIG

  • Request22 09 6C
  • Service 22DID 096C
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 100 ÷ 32767)
Range
0 to 200 %
Unit
%

In testing for 2003 to 2026.

Exhaust gas recirculation valve position measured EVEREST_EGR_VLV_POS_MEAS

  • Request22 09 FE
  • Service 22DID 09FE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 100 ÷ 32767)
Range
0 to 200 %
Unit
%

In testing for 2003 to 2026.

Exhaust gas recirculation valve position, desired EVEREST_EGR_VLV_POS_DES

  • Request22 09 D2
  • Service 22DID 09D2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 100 ÷ 32767)
Range
0 to 200 %
Unit
%

In testing for 2003 to 2026.

Exhaust gas temperature 1 EVEREST_EXH_GAS_T_1

  • Request22 03 F4
  • Service 22DID 03F4
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 5)
Range
0 to 1275 °C
Unit
°C

In testing for 2003 to 2026.

Exhaust gas temperature 2 EVEREST_EXH_GAS_T_2

  • Request22 03 F5
  • Service 22DID 03F5
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 5)
Range
0 to 1275 °C
Unit
°C

In testing for 2003 to 2026.

Exhaust gas temperature after turbo, before oxidation catalyst EVEREST_EGT_PRE_DOC

  • Request22 09 91
  • Service 22DID 0991
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val − 40)
Range
-40 to 1500 °C
Unit
°C

In testing for 2003 to 2026.

Exhaust gas temperature, bank 1 EVEREST_EGT_B1Confirmed

  • Request22 F4 78
  • Service 22DID F478
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits.

0x0105 = 261 → (261 ÷ 10 − 40) = -13.9 °C

Formula
(val ÷ 10 − 40)
Range
-40 to 6513 °C
Unit
°C

Confirmed for 2025. In testing for 2003 to 2024, 2026.

Fuel pressure sensor voltage, low EVEREST_LPFP_SENS_VConfirmed

  • Request22 05 4D
  • Service 22DID 054D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 1024)
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Fuel pressure, low actual EVEREST_LPFP_ACTConfirmed

  • Request22 05 48
  • Service 22DID 0548
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Ford Everest.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0093 = 147 → (147 × 10000 ÷ 137892) = 10.660517 psi

Formula
(val × 10000 ÷ 137892)
Range
0 to 200 psi
Unit
psi

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Fuel pressure, low desired EVEREST_LPFP_DESConfirmed

  • Request22 04 1F
  • Service 22DID 041F
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

0x95 = 149 → (149 × 435 ÷ 1000) = 64.815 psi

Formula
(val × 435 ÷ 1000)
Range
0 to 110 psi
Unit
psi

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Fuel pump duty cycle, low pressure EVEREST_LPFP_DUTYConfirmed

  • Request22 03 07
  • Service 22DID 0307
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Ford Everest.

Bits 0 to 15 of the reply, 16 bits.

0x0A3D = 2621 → (2621 × 25 ÷ 8192) = 7.998657 %

Formula
(val × 25 ÷ 8192)
Range
0 to 100 %
Unit
%

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Fuel pump pulse width, bank 2 EVEREST_FUEL_PMP_WIDTH_BANK_2

  • Request22 11 42
  • Service 22DID 1142
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 13107
Unit
Number

In testing for 2003 to 2026.

Fuel rail pressure, desired EVEREST_HPFP_DESConfirmed

  • Request22 03 DC
  • Service 22DID 03DC
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2023, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits.

0x0012 = 18 → (18 × 10) = 180 kPa

Formula
(val × 10)
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2024 to 2025. In testing for 2003 to 2023, 2026.

Fuel rail sensor voltage, high pressure EVEREST_HPFP_VConfirmed

  • Request22 03 24
  • Service 22DID 0324
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2023, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 5 ÷ 1023)
Range
0 to 5 V
Unit
V

Confirmed for 2024 to 2025. In testing for 2003 to 2023, 2026.

Fuel trim, long term EVEREST_LTFT

  • Request22 F4 07
  • Service 22DID F407
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.2 %
Unit
%

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Fuel trim, short term EVEREST_STFTConfirmed

  • Request22 F4 06
  • Service 22DID F406
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

0x7D = 125 → (125 × 100 ÷ 128 − 100) = -2.34375 %

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.2 %
Unit
%

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Generator control EVEREST_GEN_CTRL

  • Request22 03 78
  • Service 22DID 0378
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.003052)
Range
0 to 100 %
Unit
%

In testing for 2003 to 2026.

Generator current EVEREST_GEN_CURRENTConfirmed

  • Request22 04 F7
  • Service 22DID 04F7
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0xF880 = -1920 → (-1920 × 781 ÷ 50000) = -29.9904 A

Formula
(val × 781 ÷ 50000)
Range
-511.8361 to 511.8205 A
Unit
A

Confirmed for 2025. In testing for 2003 to 2024, 2026.

Glow plug, commanded status EVEREST_GLOW_PLUG_CMD_STAT

  • Request22 04 16
  • Service 22DID 0416
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 4)
Range
-4 to 251
Unit
Number

In testing for 2003 to 2026.

Grill shutter duty cycle EVEREST_GRILL_SHUT_DCConfirmed

  • Request22 07 07
  • Service 22DID 0707
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2023, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

0xB2 = 178 → (178 × 100 ÷ 255) = 69.803922 %

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2024 to 2025. In testing for 2003 to 2023, 2026.

Grill shutter position EVEREST_GRILL_SHUTTER_POSConfirmed

  • Request22 05 80
  • Service 22DID 0580
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2023, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

0xBD = 189 → (189 × 100 ÷ 255) = 74.117647 %

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2024 to 2025. In testing for 2003 to 2023, 2026.

Ignition correction, cylinder 1 EVEREST_IGN_CORR_CYL1

  • Request22 03 EC
  • Service 22DID 03EC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 512)
Range
-64 to 63.9 °
Unit
°

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Ignition timing, cylinder 1 EVEREST_IGN_TIM_CYL1Confirmed

  • Request22 11 6B
  • Service 22DID 116B
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0013 = 19 → (19 ÷ 4) = 4.75 °

Formula
(val ÷ 4)
Range
-80 to 80 °
Unit
°

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

In car temperature EVEREST_CAR_T

  • Request22 DD 04
  • Service 22DID DD04
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 8)
Range
0 to 31.875 °C
Unit
°C

In testing for 2003 to 2026.

Injection mode EVEREST_INJ_MODEConfirmed

  • Request22 04 6F
  • Service 22DID 046F
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

0x07 = 7 → 7

Formula
val
Range
0 to 7
Unit
Number

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Injector impulse width EVEREST_INJ_IMPULSE_WIDTH

  • Request22 11 41
  • Service 22DID 1141
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000022)
Range
0 to 0.05 s
Unit
s

In testing for 2003 to 2026.

Intake air temperature IATSAE J1979Confirmed

  • Request01 0F
  • Service 01PID 0F
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2024. Supported for 2025.

Intake air temperature 1 EVEREST_IAT_1

  • Request22 11 23
  • Service 22DID 1123
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °F
Unit
°F

In testing for 2003 to 2026.

Intake air temperature 2 EVEREST_IAT_2

  • Request22 16 A8
  • Service 22DID 16A8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 5 ÷ 9 − 17.777778)
Range
-17.77 to 36390 °C
Unit
°C

In testing for 2003 to 2026.

Intake air temperature, bank 1, sensor 1 IAT_11SAE J1979Confirmed

  • Request01 68
  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2024.

Intake air temperature, bank 1, sensor 2 IAT_12SAE J1979Confirmed

  • Request01 68
  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 23 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2024.

Intake temperature fault EVEREST_IAT_FAULTConfirmed

  • Request22 07 00
  • Service 22DID 0700
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2003 to 2023, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2024 to 2025. In testing for 2003 to 2023, 2026.

Intake temperature sensor voltage EVEREST_IAT_SENS_VConfirmed

  • Request22 12 79
  • Service 22DID 1279
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2023, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 5 ÷ 1023)
Range
0 to 5 V
Unit
V

Confirmed for 2024 to 2025. In testing for 2003 to 2023, 2026.

Intake temperature, alternate EVEREST_IAT_ALT2Confirmed

  • Request22 F4 0F
  • Service 22DID F40F
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2003 to 2023, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

0x5E = 94 → (94 − 40) = 54 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2024 to 2025. In testing for 2003 to 2023, 2026.

Knock counter, cylinder 1 EVEREST_PCM_CYL_1_KNK_COMB_PERF_CNTConfirmed

  • Request22 05 AC
  • Service 22DID 05AC
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Knock counter, cylinder 2 EVEREST_PCM_CYL_2_KNK_COMB_PERF_CNT

  • Request22 05 AD
  • Service 22DID 05AD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Knock counter, cylinder 3 EVEREST_PCM_CYL_3_KNK_COMB_PERF_CNTConfirmed

  • Request22 05 AE
  • Service 22DID 05AE
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

0x01 = 1 → 1

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Knock counter, cylinder 4 EVEREST_PCM_CYL_4_KNK_COMB_PERF_CNTConfirmed

  • Request22 05 AF
  • Service 22DID 05AF
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Knock counter, cylinder 5 EVEREST_PCM_CYL_5_KNK_COMB_PERF_CNT

  • Request22 05 B0
  • Service 22DID 05B0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Knock counter, cylinder 6 EVEREST_PCM_CYL_6_KNK_COMB_PERF_CNT

  • Request22 05 B1
  • Service 22DID 05B1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Knock sensor, 1 EVEREST_KS1_RAWConfirmed

  • Request22 04 03
  • Service 22DID 0403
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits.

0x0028 = 40 → 40

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Knock sensor, 2 EVEREST_KS2_RAW

  • Request22 04 04
  • Service 22DID 0404
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Lambda correction EVEREST_CL_LC

  • Request22 03 BD
  • Service 22DID 03BD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 8192)
Range
-4 to 3.9
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Lambda, commanded EVEREST_CL

The ratio of oxygen in the combustion chamber compared to the amount that should have been present for ideal combustion.

  • Request22 03 0F
  • Service 22DID 030F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32768)
Range
0 to 1.9999
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Low oil pressure switch EVEREST_LOW_OIL_P_SWITCH

  • Request22 04 16
  • Service 22DID 0416
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2026.

Manifold absolute pressure, high resolution EVEREST_MAP_HIRESConfirmed

  • Request22 03 70
  • Service 22DID 0370
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits.

0x006E = 110 → (110 ÷ 4) = 27.5 kPa

Formula
(val ÷ 4)
Range
0 to 16383.75 kPa
Unit
kPa

Confirmed for 2025. In testing for 2003 to 2024, 2026.

Manifold air temperature EVEREST_MANIFOLD_AIR_T

  • Request22 16 E0
  • Service 22DID 16E0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 9 ÷ 5 − 40)
Range
-40 to 419 °F
Unit
°F

In testing for 2003 to 2026.

Manifold pressure EVEREST_MAPConfirmed

  • Request22 F4 0B
  • Service 22DID F40B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2003 to 2023, 2025 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 10000 ÷ 68947)
Range
0 to 36 psi
Unit
psi

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Manifold pressure sensor voltage EVEREST_MAP_VConfirmed

Typically varies from 1 volt at idle to 5 volts during wide open throttle.

  • Request22 03 01
  • Service 22DID 0301
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2023, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 5 V
Unit
V

Confirmed for 2024 to 2025. In testing for 2003 to 2023, 2026.

Manifold temperature EVEREST_MCT

  • Request22 03 CA
  • Service 22DID 03CA
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 148.889 °C
Unit
°C

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Mass Air Flow Sensor A MAFASAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Request01 66
  • Service 01PID 66
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 23 of the reply, 16 bits.

Formula
(val ÷ 32)
Range
0 to 2047.96875 g/s
Unit
g/s

Confirmed for 2024.

Mass Air Flow Sensor B MAFBSAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Request01 66
  • Service 01PID 66
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 39 of the reply, 16 bits.

Formula
(val ÷ 32)
Range
0 to 2047.96875 g/s
Unit
g/s

Confirmed for 2024.

Mass airflow sensor frequency EVEREST_MASS_AIRFLOW_SENS

  • Request22 03 3D
  • Service 22DID 033D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383 Hz
Unit
Hz

In testing for 2003 to 2026.

Misfire acceleration, cylinder 1 EVEREST_PCM_MISF_ACCEL_CYL1_NORMConfirmed

  • Request22 03 82
  • Service 22DID 0382
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

0x00 = 0 → (0 ÷ 64) = 0

Formula
(val ÷ 64)
Range
-2 to 1.98
Unit
Number

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Misfire acceleration, cylinder 2 EVEREST_PCM_MISF_ACCEL_CYL2_NORMConfirmed

  • Request22 03 88
  • Service 22DID 0388
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

0x00 = 0 → (0 ÷ 64) = 0

Formula
(val ÷ 64)
Range
-2 to 1.98
Unit
Number

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Misfire acceleration, cylinder 3 EVEREST_PCM_MISF_ACCEL_CYL3_NORM

  • Request22 03 8A
  • Service 22DID 038A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
(val ÷ 64)
Range
-2 to 1.98
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Misfire acceleration, cylinder 4 EVEREST_PCM_MISF_ACCEL_CYL4_NORMConfirmed

  • Request22 03 8B
  • Service 22DID 038B
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

0x00 = 0 → (0 ÷ 64) = 0

Formula
(val ÷ 64)
Range
-2 to 1.98
Unit
Number

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Misfire acceleration, cylinder 5 EVEREST_PCM_MISF_ACCEL_CYL5_NORM

  • Request22 03 8C
  • Service 22DID 038C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
(val ÷ 64)
Range
-2 to 1.98
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Misfire acceleration, cylinder 6 EVEREST_PCM_MISF_ACCEL_CYL6_NORM

  • Request22 03 98
  • Service 22DID 0398
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
(val ÷ 64)
Range
-2 to 1.98
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Misfire events, latest cycle EVEREST_PCM_MISF_EVENTS_LATEST_CYC

  • Request22 03 45
  • Service 22DID 0345
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Navigation altitude EVEREST_SYNC_GPS_ALTITUDE

  • Request22 80 12
  • Service 22DID 8012
  • Module7D0 → 7D8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2026.

Navigation heading EVEREST_SYNC_GPS_HEADING

  • Request22 80 12
  • Service 22DID 8012
  • Module7D0 → 7D8
  • Every250 ms
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °
Unit
°

In testing for 2003 to 2026.

O2 sensor voltage, rear EVEREST_RO2_VConfirmed

  • Request22 03 5F
  • Service 22DID 035F
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 1 V
Unit
V

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Octane adjustment EVEREST_OAR

  • Request22 03 E8
  • Service 22DID 03E8
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16384)
Range
0 to 1
Unit
Number

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Oil life remaining EVEREST_PCM_ENG_OIL_LIFE_REMConfirmed

  • Request22 05 4B
  • Service 22DID 054B
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2003 to 2023, 2025 to 2026

Example reply from a 2024 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

0x2E = 46 → 46 %

Formula
val
Range
0 to 100 %
Unit
%

Confirmed for 2024. In testing for 2003 to 2023, 2025 to 2026.

Oil pressure EVEREST_PCM_ENG_EOP_RAWConfirmed

  • Request22 04 15
  • Service 22DID 0415
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2024, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x012D = 301 → 301 kPa

Formula
val
Range
-32768 to 32767 kPa
Unit
kPa

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Sump oil temperature measured EVEREST_SUMP_OIL_T_MEAS

  • Request22 03 F3
  • Service 22DID 03F3
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2003 to 2026.

Throttle angle, actual EVEREST_ETC_ANG_ACTConfirmed

  • Request22 09 3C
  • Service 22DID 093C
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2003 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 512)
Range
0 to 127.99 °
Unit
°

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Throttle angle, desired EVEREST_ETC_ANG_DES

  • Request22 09 1A
  • Service 22DID 091A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 512)
Range
0 to 127.99 °
Unit
°

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Throttle control trim angle, learned EVEREST_ETC_TRIM_LRNConfirmed

  • Request22 03 38
  • Service 22DID 0338
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2003 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 512)
Range
-64 to 63.9 °
Unit
°

Confirmed for 2025. In testing for 2003 to 2023, 2026. Not supported for 2024.

Throttle inlet pressure EVEREST_TIP_ABS

  • Request22 03 3E
  • Service 22DID 033E
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 37 ÷ 33441)
Range
0 to 60 psi
Unit
psi

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Throttle inlet pressure sensor voltage EVEREST_TIP_V

  • Request22 03 3C
  • Service 22DID 033C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 5 ÷ 1024)
Range
0 to 5 V
Unit
V

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Throttle inlet pressure, desired EVEREST_TIP_DES_ABSConfirmed

  • Request22 04 66
  • Service 22DID 0466
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2003 to 2023, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits.

0x2F26 = 12070 → (12070 × 37 ÷ 33441) = 13.354565 psi

Formula
(val × 37 ÷ 33441)
Range
0 to 72.5 psi
Unit
psi

Confirmed for 2024 to 2025. In testing for 2003 to 2023, 2026.

Time since last oil change EVEREST_TIME_SINCE_OIL

  • Request22 05 3F
  • Service 22DID 053F
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 200 ÷ 13107)
Range
0 to 1000
Unit
Raw value

In testing for 2003 to 2026.

Torque converter slip EVEREST_TQ_CONV_SLIP

  • Request22 11 B8
  • Service 22DID 11B8
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1.638538424)
Range
0 to 39996.0104 rpm
Unit
rpm

In testing for 2003 to 2026.

Torque into torque converter EVEREST_TQ_INTO_TQ_CONV

  • Request22 09 CB
  • Service 22DID 09CB
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1.35581795)
Range
0 to 48336.1353 N·m
Unit
N·m

In testing for 2003 to 2024, 2026. Not supported for 2025.

Torque into torque converter EVEREST_TQ_INTO_TQ_CONV_7E0

  • Request22 16 3A
  • Service 22DID 163A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 0.2711635897)
Range
0 to 69.1467 N·m
Unit
N·m

In testing for 2003 to 2026.

Torque request EVEREST_TRQ_CTRL_REQ

  • Request22 03 AF
  • Service 22DID 03AF
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2003 to 2023, 2025 to 2026. Not supported for 2024.

Total misfire count EVEREST_TOT_MIS_CNT

  • Request22 16 16
  • Service 22DID 1616
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2026.

Transfer case fluid temperature EVEREST_TRANSFER_CASE_FLUID_T

  • Request22 07 0D
  • Service 22DID 070D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16)
Range
-2048 to 2047.9375 °C
Unit
°C

In testing for 2003 to 2026.

Transmission fluid temperature, variant 1 EVEREST_ATF_T_VAR_1

  • Request22 16 74
  • Service 22DID 1674
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 8)
Range
0 to 8191 °F
Unit
°F

In testing for 2003 to 2026.

Transmission fluid temperature, variant 2 EVEREST_ATF_T_VAR_2

  • Request22 16 74
  • Service 22DID 1674
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °F
Unit
°F

In testing for 2003 to 2026.

Transmission fluid temperature, variant 5 EVEREST_ATF_T_VAR_5

  • Request22 1E 3F
  • Service 22DID 1E3F
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2003 to 2026.

Transmission fluid temperature, variant 6 EVEREST_ATF_T_VAR_6

  • Request22 09 2C
  • Service 22DID 092C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °F
Unit
°F

In testing for 2003 to 2026.

Turbo boost EVEREST_TURBO_BOOST

  • Request22 09 DB
  • Service 22DID 09DB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

In testing for 2003 to 2026.

Turbo inlet pressure EVEREST_TURBO_INLET_P

  • Request22 05 BE
  • Service 22DID 05BE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16)
Range
0 to 4095.9375 kPa
Unit
kPa

In testing for 2003 to 2026.

Variable geometry turbo duty cycle EVEREST_VGT_DUTY

  • Request22 09 6D
  • Service 22DID 096D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 100 ÷ 32767)
Range
0 to 200 %
Unit
%

In testing for 2003 to 2026.

Warm-ups since DTC clear EVEREST_WARMUP_CLRConfirmed

  • Request22 F4 30
  • Service 22DID F430
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2003 to 2023, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 7 of the reply, 8 bits.

0xE5 = 229 → 229

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2024 to 2025. In testing for 2003 to 2023, 2026.

Wastegate control EVEREST_WASTEGATE_CTRL

  • Request22 16 E1
  • Service 22DID 16E1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 763 ÷ 50000)
Range
0 to 100 %
Unit
%

In testing for 2003 to 2026.

Wastegate duty cycle EVEREST_WGDCConfirmed

  • Request22 04 62
  • Service 22DID 0462
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2023, 2026

Example reply from a 2025 Ford Everest.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → (0 × 100 ÷ 32768) = 0 %

Formula
(val × 100 ÷ 32768)
Range
0 to 100 %
Unit
%

Confirmed for 2024 to 2025. In testing for 2003 to 2023, 2026.

Engine › AuxInputs

Auto Trans Neutral Drive Status N/D_STATSAE J1979Confirmed

  • Request01 65
  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Glow plug lamp status GPL_STATSAE J1979Confirmed

  • Request01 65
  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Manual Trans Neutral Gear Status N/G_STATSAE J1979Confirmed

  • Request01 65
  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Power Take Off (PTO) Output Status PTO_STAT_AUXSAE J1979Confirmed

  • Request01 65
  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Recommended gear GEAR_RCMDSAE J1979Confirmed

  • Request01 65
  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 11 of the reply, 4 bits.

Formula
val
Range
0 to 15
Unit
No or yes

Confirmed for 2024.

Engine › AuxInputs › Internal

Auto trans neutral drive status supported N/D_SUPSAE J1979Confirmed

  • Request01 65
  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Glow plug lamp status supported GPL_SUPSAE J1979Confirmed

  • Request01 65
  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Manual trans neutral gear status supported N/G_SUPSAE J1979Confirmed

  • Request01 65
  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Power Take Off (PTO) output status supported PTO_SUPSAE J1979Confirmed

  • Request01 65
  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Recommended gear supported GEAR_SUPSAE J1979Confirmed

  • Request01 65
  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Engine › Internal

Actual EGR A supported EGR_A_ACT_SUPSAE J1979Confirmed

  • Request01 69
  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Actual EGR A supported EGR_B_ACT_SUPSAE J1979Confirmed

  • Request01 69
  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Boost bressure A control status BP_ASAE J1979Confirmed

  • Request01 70
  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 78 to 79 of the reply, 2 bits.

Unit
Named states
States
Raw valueStateMeaning
1BP_A_OLOpen loop
2BP_A_CLClosed loop
3BP_A_FAULTFault

Confirmed for 2024.

Boost bressure A control status BP_BSAE J1979Confirmed

  • Request01 70
  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 76 to 77 of the reply, 2 bits.

Unit
Named states
States
Raw valueStateMeaning
1BP_B_OLOpen loop
2BP_B_CLClosed loop
3BP_B_FAULTFault

Confirmed for 2024.

Boost pressure A control status supported BP_A_SUPSAE J1979Confirmed

  • Request01 70
  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Boost pressure A supported BP_A_ACT_SUPSAE J1979Confirmed

  • Request01 70
  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Boost pressure B control status supported BP_B_SUPSAE J1979Confirmed

  • Request01 70
  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Boost pressure B supported BP_B_ACT_SUPSAE J1979Confirmed

  • Request01 70
  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Commanded boost pressure A supported BP_A_CMD_SUPSAE J1979Confirmed

  • Request01 70
  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Commanded boost pressure B supported BP_B_CMD_SUPSAE J1979Confirmed

  • Request01 70
  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Commanded EGR A supported EGR_A_CMD_SUPSAE J1979Confirmed

  • Request01 69
  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Commanded EGR A supported EGR_B_CMD_SUPSAE J1979Confirmed

  • Request01 69
  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

EGR A error supported EGR_A_ERR_SUPSAE J1979Confirmed

  • Request01 69
  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

EGR A error supported EGR_B_ERR_SUPSAE J1979Confirmed

  • Request01 69
  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

IAT Bank 1, Sensor 1 supported IAT_11_SUPSAE J1979Confirmed

  • Request01 68
  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

IAT Bank 1, Sensor 1 supported IAT_21_SUPSAE J1979Confirmed

  • Request01 68
  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

IAT Bank 1, Sensor 2 supported IAT_12_SUPSAE J1979Confirmed

  • Request01 68
  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

IAT Bank 1, Sensor 3 supported IAT_13_SUPSAE J1979Confirmed

  • Request01 68
  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

IAT Bank 2, Sensor 2 supported IAT_22_SUPSAE J1979Confirmed

  • Request01 68
  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

IAT Bank 2, Sensor 3 supported IAT_23_SUPSAE J1979Confirmed

  • Request01 68
  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Is ECT sensor 1 supported? ECT_1_SUPSAE J1979Confirmed

  • Request01 67
  • Service 01PID 67
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

Confirmed for 2024.

Is ECT sensor 2 supported? ECT_2_SUPSAE J1979Confirmed

  • Request01 67
  • Service 01PID 67
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Number

Confirmed for 2024.

MAF Sensor A supported MAFA_SUPSAE J1979Confirmed

  • Request01 66
  • Service 01PID 66
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

MAF Sensor B supported MAFB_SUPSAE J1979Confirmed

  • Request01 66
  • Service 01PID 66
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.