Ford Flex

FORD_VCT_INT parameters

The Ford Flex has 4 FORD_VCT_INT parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Variable camshaft timing intake cam desired FORD_VCT_INT_DESConfirmed

  • Request22 03 BC
  • Service 22DID 03BC
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Example reply from a 2016 Ford Flex.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0000 = 0 → (0 ÷ 16) = 0 °

Formula
(val ÷ 16)
Range
-2047 to 2047 °
Unit
°

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Variable camshaft timing intake cam desired FORD_VCT_INT_DESConfirmed

  • Request22 03 BC
  • Service 22DID 03BC
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Example reply from a 2016 Ford Flex.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0000 = 0 → (0 ÷ 16) = 0 °

Formula
(val ÷ 16)
Range
-2047 to 2047 °
Unit
°

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Variable camshaft timing intake camshaft actual FORD_VCT_INT_ACTConfirmed

  • Request22 03 18
  • Service 22DID 0318
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Example reply from a 2016 Ford Flex.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → (0 ÷ 16) = 0 °

Formula
(val ÷ 16)
Range
0 to 0 °
Unit
°

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Variable camshaft timing intake camshaft error FORD_VCT_INT_ERRConfirmed

  • Request22 03 1A
  • Service 22DID 031A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Example reply from a 2016 Ford Flex.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0000 = 0 → (0 ÷ 16) = 0 °

Formula
(val ÷ 16)
Range
-50 to 50 °
Unit
°

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Variable camshaft timing intake camshaft solenoid duty cycle FORD_VCT_INT_DUTYConfirmed

  • Request22 03 16
  • Service 22DID 0316
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Example reply from a 2016 Ford Flex.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → (0 × 0.0030517578) = 0 %

Formula
(val × 0.0030517578)
Range
0 to 100 %
Unit
%

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.