Battery parameters
The Genesis G70 has 682 battery parameters.
● Confirmed◆ In testing○ Supported× Not supported
12v battery charge GENESIS_VPWR_V3
- Request
22 E0 04 - Service 22
DID E004 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 152 to 159 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
12V battery state of charge GENESIS_BATTERY_SOC
- Request
22 E0 01 - Service 22
DID E001 - Module
7E0 → 7E8 - Every
2 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 2017 to 2026.
48 battery state of charge GENESIS_48_BAT_ST_CHG
- Request
22 02 01 - Service 22
DID 0201 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 152 to 167 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 6553 %
- Unit
- %
In testing for 2017 to 2026.
48 battery state of charge 2 GENESIS_48_BAT_ST_CHG_2
- Request
22 02 05 - Service 22
DID 0205 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 %
- Unit
- %
In testing for 2017 to 2026.
48V battery charge limit GENESIS_48V_BAT_CHG_LIM
- Request
22 02 05 - Service 22
DID 0205 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 216 to 231 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 A
- Unit
- A
In testing for 2017 to 2026.
48V battery current GENESIS_48V_BAT_CURRENT_7E4
- Request
22 02 04 - Service 22
DID 0204 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 80 to 95 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 A
- Unit
- A
In testing for 2017 to 2026.
48V battery current monitoring GENESIS_48V_BAT_CURRENT
- Request
22 02 04 - Service 22
DID 0204 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 64 to 79 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 A
- Unit
- A
In testing for 2017 to 2026.
48V battery voltage GENESIS_48V_BAT_V
- Request
22 02 05 - Service 22
DID 0205 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 328 to 343 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2017 to 2026.
A/C charger current GENESIS_AC_CHARGER_CURRENT
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing
Bits 304 to 319 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 A
- Unit
- A
In testing for 2017 to 2026.
A/C charging counter GENESIS_HVBAT_AC_CHARGING_COUNTER
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
A/C charging time GENESIS_VCMS__AC_CHARGING_TIME
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 h
- Unit
- h
In testing for 2017 to 2026.
A/C charging time, after plug-in GENESIS_AC_CHARGING_TIME_AFTER_PLUG_IN
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing
Bits 336 to 351 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 min
- Unit
- min
In testing for 2017 to 2026.
Airbag hard-wire duty GENESIS_AIRBAG_DUTY
- Request
22 01 05 - Service 22
DID 0105 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Airbag hard-wire duty GENESIS_AIRBAG_DUTY_V2
- Request
21 05 - Service 21
PID 05 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Aux battery state of charge GENESIS_AUX_SOC
- Request
22 E0 04 - Service 22
DID E004 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 320 to 327 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Aux battery state of health GENESIS_AUX_SOH
- Request
22 E0 04 - Service 22
DID E004 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 328 to 335 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Auxiliary battery current GENESIS_2025_AUX_BATTERY_CURRENT
- Request
22 E1 01 - Service 22
DID E101 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327)- Range
- -327 to 328.35 A
- Unit
- A
In testing for 2017 to 2026.
Auxiliary battery current GENESIS_AUX_BATTERY_CURRENT
- Request
22 E0 11 - Service 22
DID E011 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327)- Range
- -327 to 328.35 A
- Unit
- A
In testing for 2017 to 2026.
Auxiliary battery current GENESIS_AUXILIARY_BAT
- Request
21 02 - Service 21
PID 02 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 168 to 183 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 A
- Unit
- A
In testing for 2017 to 2026.
Auxiliary battery state of charge GENESIS_2025_AUX_BATTERY_STATE_OF_CHARGE
- Request
22 E1 01 - Service 22
DID E101 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 160 to 167 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Auxiliary battery state of charge GENESIS_AUX_BATTERY_STATE_OF_CHARGE
- Request
22 E0 11 - Service 22
DID E011 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 160 to 167 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Auxiliary battery state of charge GENESIS_AUXILIARY_BAT_ST_CHG
- Request
21 02 - Service 21
PID 02 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 2017 to 2026.
Auxiliary battery temperature GENESIS_2025_AUX_BATTERY_T
- Request
22 E1 01 - Service 22
DID E101 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 184 to 199 of the reply, 16 bits.
- Formula
(val ÷ 2 − 40)- Range
- -40 to 32727.5 °C
- Unit
- °C
In testing for 2017 to 2026.
Auxiliary battery temperature GENESIS_AUX_BATTERY_T
- Request
22 E0 11 - Service 22
DID E011 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 184 to 199 of the reply, 16 bits.
- Formula
(val ÷ 2 − 40)- Range
- -40 to 32727.5 °C
- Unit
- °C
In testing for 2017 to 2026.
Auxiliary battery voltage GENESIS_12V_V
Pelican can show this parameter as the starter battery voltage.
- Request
22 E0 04 - Service 22
DID E004 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4.883 ÷ 10000)- Range
- 0 to 32 V
- Unit
- V
In testing for 2017 to 2026.
Auxiliary battery voltage GENESIS_2025_AUX_BATTERY_VOLTAGE
Pelican can show this parameter as the starter battery voltage.
- Request
22 E1 01 - Service 22
DID E101 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 168 to 183 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 6)- Range
- 6 to 71.535 V
- Unit
- V
In testing for 2017 to 2026.
Auxiliary battery voltage GENESIS_AUX_BATTERY_VOLTAGE_7E5
Pelican can show this parameter as the starter battery voltage.
- Request
22 E0 11 - Service 22
DID E011 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 168 to 183 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 6)- Range
- 6 to 71.535 V
- Unit
- V
In testing for 2017 to 2026.
Auxiliary battery voltage GENESIS_AUXILIARY_BAT_V
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 232 to 239 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2017 to 2026.
Auxiliary battery voltage GENESIS_AUXILLARY_BATTERY_VOLTAGE
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 232 to 239 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 11 to 14.6 V
- Unit
- V
In testing for 2017 to 2026.
Auxiliary battery voltage, vehicle control unit GENESIS_AUX_V_7E2
- Request
21 02 - Service 21
PID 02 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 152 to 167 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val ÷ 1000)- Range
- -32.768 to 32.767 V
- Unit
- V
In testing for 2017 to 2026.
Available charge power GENESIS_AVAILABLE_CHG_POWER
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 kW
- Unit
- kW
In testing for 2017 to 2026.
Available charge power GENESIS_BMS_CHG_PWR
- Request
22 01 01 - Service 22
DID 0101 - Module
7D4 → 7DC - Every
5 s - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 kW
- Unit
- kW
In testing for 2017 to 2026.
Available charge power GENESIS_HVBAT_CHG_P_AVAIL
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 kW
- Unit
- kW
In testing for 2017 to 2026.
Available discharge power GENESIS_AVAILABLE_DCHG_POWER
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 56 to 71 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 kW
- Unit
- kW
In testing for 2017 to 2026.
Available discharge power GENESIS_BMS_DISCHG_PWR
- Request
22 01 01 - Service 22
DID 0101 - Module
7D4 → 7DC - Every
5 s - Testing
Bits 56 to 71 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 kW
- Unit
- kW
In testing for 2017 to 2026.
Available discharge power GENESIS_HVBAT_DCHG_P_AVAIL
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 56 to 71 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 kW
- Unit
- kW
In testing for 2017 to 2026.
Battery auxiliary voltage GENESIS_VPWR
Pelican can show this parameter as the starter battery voltage.
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 232 to 239 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 255 V
- Unit
- V
In testing for 2017 to 2026.
Battery auxiliary voltage GENESIS_VPWR_V2
Pelican can show this parameter as the starter battery voltage.
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 232 to 239 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2017 to 2026.
Battery capacity, battery sensor GENESIS_BAT_CAP_BATSENS
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 160 to 167 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 Ah
- Unit
- Ah
In testing for 2017 to 2026.
Battery cell voltage deviation GENESIS_HVBAT_C_DEV_V_V2
- Request
21 05 - Service 21
PID 05 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 160 to 167 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery charge flag, battery sensor GENESIS_BAT_CHG_FLAG_BATSENS
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bit 183 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2017 to 2026.
Battery current GENESIS_BAT_CURRENT
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 256 to 271 of the reply, 16 bits. The value is signed.
- Formula
(val × 1000 ÷ 10000)- Range
- -3276.8 to 3276.7 A
- Unit
- A
In testing for 2017 to 2026.
Battery current GENESIS_BAT_CURRENT_7E4
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 80 to 95 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 A
- Unit
- A
In testing for 2017 to 2026.
Battery current GENESIS_BATTERY_CURRENT
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -230 to 230 A
- Unit
- A
In testing for 2017 to 2026.
Battery current, battery sensor GENESIS_BAT_CURRENT_BATSENS
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 A
- Unit
- A
In testing for 2017 to 2026.
Battery current, battery sensor GENESIS_BAT_CURRENT_BATSENS_7E0_7E0_06
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 736 to 751 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val ÷ 16)- Range
- -2048 to 2047.9375 A
- Unit
- A
In testing for 2017 to 2026.
Battery current, battery sensor GENESIS_BAT_CURRENT_BATSENS_7E0_7E0_27
- Request
21 27 - Service 21
PID 27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 48 to 63 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 A
- Unit
- A
In testing for 2017 to 2026.
Battery DC voltage GENESIS_BAT_DC_V
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 V
- Unit
- V
In testing for 2017 to 2026.
Battery DC voltage GENESIS_BATTERY_DC_VOLTAGE
Pelican can show this parameter as the traction battery voltage.
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 1000 V
- Unit
- V
In testing for 2017 to 2026.
Battery fan duty feedback GENESIS_BAT_FAN_DUTY
- Request
22 01 06 - Service 22
DID 0106 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 2017 to 2026.
Battery fan duty feedback GENESIS_HVBAT_FAN_DUTY
- Request
22 01 06 - Service 22
DID 0106 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Battery fan feedback GENESIS_BAT_FAN_FEEDBACK
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 224 to 231 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 Hz
- Unit
- Hz
In testing for 2017 to 2026.
Battery fan feedback GENESIS_BATTERY_FAN_FEEDBACK
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 224 to 231 of the reply, 8 bits.
- Formula
val- Range
- 0 to 120 Hz
- Unit
- Hz
In testing for 2017 to 2026.
Battery fan status GENESIS_BAT_FAN_STAT
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 216 to 223 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Battery fan status GENESIS_BATTERY_FAN_STATUS
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 216 to 223 of the reply, 8 bits.
- Formula
val- Range
- 0 to 9
- Unit
- Number
In testing for 2017 to 2026.
Battery health aging flag, battery sensor GENESIS_BAT_HEALTH_AGING
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bit 182 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2017 to 2026.
Battery heater 1 temperature GENESIS_HVBAT_HTR1_T_V2
- Request
21 05 - Service 21
PID 05 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2017 to 2026.
Battery heater 2 temperature GENESIS_HVBAT_HTR2_T_V2
- Request
21 05 - Service 21
PID 05 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 192 to 199 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2017 to 2026.
Battery inlet temperature GENESIS_BAT_INLET_T
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 176 to 183 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2017 to 2026.
Battery inlet temperature GENESIS_BATTERY_INLET_T
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 80 °C
- Unit
- °C
In testing for 2017 to 2026.
Battery inlet temperature GENESIS_HVBAT_INLET_T
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 176 to 183 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -127 to 127 °C
- Unit
- °C
In testing for 2017 to 2026.
Battery is in use to crank the engine flag, battery sensor GENESIS_BAT_CRANK_ENG_FLAG
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bit 181 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2017 to 2026.
Battery management state GENESIS_BMS_STATE
- Request
22 01 06 - Service 22
DID 0106 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 15
- Unit
- Number
In testing for 2017 to 2026.
Battery management system ignition GENESIS_BMS_IGNITION
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bit 405 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 2017 to 2026.
Battery management system main relay GENESIS_BMS_MAIN_RELAY
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bit 79 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 2017 to 2026.
Battery max temperature GENESIS_BAT_MAX_T
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 112 to 119 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2017 to 2026.
Battery max temperature GENESIS_BATTERY_MAX_T
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 112 to 119 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -40 to 80 °C
- Unit
- °C
In testing for 2017 to 2026.
Battery min temp GENESIS_BMS_MIN_TEMP
- Request
22 01 01 - Service 22
DID 0101 - Module
7D4 → 7DC - Every
5 s - Testing
Bits 120 to 127 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -40 to 80 °C
- Unit
- °C
In testing for 2017 to 2026.
Battery min temperature GENESIS_BAT_MIN_T
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 120 to 127 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2017 to 2026.
Battery min temperature GENESIS_BATTERY_MIN_T
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 120 to 127 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -40 to 80 °C
- Unit
- °C
In testing for 2017 to 2026.
Battery mod 1 temp GENESIS_BMS_MOD1_TEMP
- Request
22 01 01 - Service 22
DID 0101 - Module
7D4 → 7DC - Every
5 s - Testing
Bits 128 to 135 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -40 to 80 °C
- Unit
- °C
In testing for 2017 to 2026.
Battery mod 2 temp GENESIS_BMS_MOD2_TEMP
- Request
22 01 01 - Service 22
DID 0101 - Module
7D4 → 7DC - Every
5 s - Testing
Bits 136 to 143 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -40 to 80 °C
- Unit
- °C
In testing for 2017 to 2026.
Battery mod 3 temp GENESIS_BMS_MOD3_TEMP
- Request
22 01 01 - Service 22
DID 0101 - Module
7D4 → 7DC - Every
5 s - Testing
Bits 144 to 151 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -40 to 80 °C
- Unit
- °C
In testing for 2017 to 2026.
Battery mod 4 temp GENESIS_BMS_MOD4_TEMP
- Request
22 01 01 - Service 22
DID 0101 - Module
7D4 → 7DC - Every
5 s - Testing
Bits 152 to 159 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -40 to 80 °C
- Unit
- °C
In testing for 2017 to 2026.
Battery module 01 temperature GENESIS_BAT_MODULE_01_T
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 128 to 135 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2017 to 2026.
Battery module 02 temperature GENESIS_BAT_MODULE_02_T
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 136 to 143 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2017 to 2026.
Battery module 03 temperature GENESIS_BAT_MODULE_03_T
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 144 to 151 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2017 to 2026.
Battery module 04 temperature GENESIS_BAT_MODULE_04_T
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 152 to 159 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2017 to 2026.
Battery module 05 temperature GENESIS_BAT_MODULE_05_T
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 160 to 167 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2017 to 2026.
Battery module 06 temperature GENESIS_HVBAT_MOD06_T
- Request
21 05 - Service 21
PID 05 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2017 to 2026.
Battery module 07 temperature GENESIS_HVBAT_MOD07_T
- Request
21 05 - Service 21
PID 05 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2017 to 2026.
Battery module 08 temperature GENESIS_HVBAT_MOD08_T
- Request
21 05 - Service 21
PID 05 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2017 to 2026.
Battery module 09 temperature GENESIS_HVBAT_MOD09_T
- Request
21 05 - Service 21
PID 05 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2017 to 2026.
Battery module 10 temperature GENESIS_HVBAT_MOD10_T
- Request
21 05 - Service 21
PID 05 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 104 to 111 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2017 to 2026.
Battery module 11 temperature GENESIS_HVBAT_MOD11_T
- Request
21 05 - Service 21
PID 05 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 112 to 119 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2017 to 2026.
Battery module 12 temperature GENESIS_HVBAT_MOD12_T
- Request
21 05 - Service 21
PID 05 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 120 to 127 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2017 to 2026.
Battery pack B01 GENESIS_BATTERY_PACK_B01
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 128 to 135 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -40 to 80 °C
- Unit
- °C
In testing for 2017 to 2026.
Battery pack B02 GENESIS_BATTERY_PACK_B02
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 136 to 143 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -40 to 80 °C
- Unit
- °C
In testing for 2017 to 2026.
Battery pack B03 GENESIS_BATTERY_PACK_B03
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 144 to 151 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -40 to 80 °C
- Unit
- °C
In testing for 2017 to 2026.
Battery pack B04 GENESIS_BATTERY_PACK_B04
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 152 to 159 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -40 to 80 °C
- Unit
- °C
In testing for 2017 to 2026.
Battery pack B05 GENESIS_BATTERY_PACK_B05
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 160 to 167 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -40 to 80 °C
- Unit
- °C
In testing for 2017 to 2026.
Battery pack B17 GENESIS_BATTERY_PACK_B17
- Request
22 01 11 - Service 22
DID 0111 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 208 to 215 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -40 to 80 °C
- Unit
- °C
In testing for 2017 to 2026.
Battery pack B18 GENESIS_BATTERY_PACK_B18
- Request
22 01 11 - Service 22
DID 0111 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 216 to 223 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -40 to 80 °C
- Unit
- °C
In testing for 2017 to 2026.
Battery quiescent current flag, battery sensor GENESIS_BAT_QUIESCENT
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bit 180 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2017 to 2026.
Battery sensor invalid condition flag, battery sensor GENESIS_BATSENS_INVALID_COND
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bit 179 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2017 to 2026.
Battery state of charge, battery sensor GENESIS_BAT_ST_CHG_BATSENS
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Battery state of charge, battery sensor GENESIS_BAT_ST_CHG_BATSENS_7E0_7E0_06
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 784 to 791 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Battery state of charge, battery sensor GENESIS_BAT_ST_CHG_BATSENS_7E0_7E0_27
- Request
21 27 - Service 21
PID 27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 2017 to 2026.
Battery state of function, battery sensor GENESIS_BAT_ST_FUNCTION
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val × 12.75 ÷ 255)- Range
- 0 to 12.75 V
- Unit
- V
In testing for 2017 to 2026.
Battery state of function, battery sensor GENESIS_BAT_ST_FUNCTION_BATSENS
- Request
21 27 - Service 21
PID 27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val ÷ 20)- Range
- 0 to 12.75 V
- Unit
- V
In testing for 2017 to 2026.
Battery state of health, battery sensor GENESIS_BAT_ST_HEALTH
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Battery state of health, battery sensor GENESIS_BAT_ST_HEALTH_BATSENS
- Request
21 27 - Service 21
PID 27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 2017 to 2026.
Battery temperature GENESIS_BAT_T
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
(val ÷ 2)- Range
- 0 to 32767.5 °C
- Unit
- °C
In testing for 2017 to 2026.
Battery temperature 1 GENESIS_BAT_T_1
- Request
22 02 04 - Service 22
DID 0204 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 96 to 111 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 °C
- Unit
- °C
In testing for 2017 to 2026.
Battery temperature 2 GENESIS_BAT_T_2
- Request
22 02 04 - Service 22
DID 0204 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 112 to 127 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 °C
- Unit
- °C
In testing for 2017 to 2026.
Battery temperature at the power relay assembly GENESIS_HVBAT_PRA_T
- Request
22 01 06 - Service 22
DID 0106 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 160 to 167 of the reply, 8 bits. The value is signed.
- Formula
(val × 2)- Range
- -256 to 254 °C
- Unit
- °C
In testing for 2017 to 2026.
Battery temperature at WCS input GENESIS_HVBAT_WCS_INLET_T
- Request
22 01 06 - Service 22
DID 0106 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 32 to 39 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2017 to 2026.
Battery temperature, battery sensor GENESIS_BAT_T_BATSENS
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- -40 to 87.5 °C
- Unit
- °C
In testing for 2017 to 2026.
Battery temperature, battery sensor GENESIS_BAT_T_BATSENS_7E0_7E0_06
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 768 to 783 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val × 1953 ÷ 250000)- Range
- -255.9836 to 255.9758 °C
- Unit
- °C
In testing for 2017 to 2026.
Battery temperature, battery sensor GENESIS_BAT_T_BATSENS_7E0_7E0_27
- Request
21 27 - Service 21
PID 27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
(val ÷ 2 − 40)- Range
- -40 to 32727 °C
- Unit
- °C
In testing for 2017 to 2026.
Battery voltage GENESIS_BAT_V
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
(val × 10 ÷ 10000 + 6)- Range
- 0 to 71.535 V
- Unit
- V
In testing for 2017 to 2026.
Battery voltage GENESIS_BATTERY_V
- Request
22 E0 01 - Service 22
DID E001 - Module
7E0 → 7E8 - Every
2 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 17.37 ÷ 255)- Range
- 0 to 17.37 V
- Unit
- V
In testing for 2017 to 2026.
Battery voltage GENESIS_BATTERY_V_26
- Request
22 E0 01 - Service 22
DID E001 - Module
7E0 → 7E8 - Every
2 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 17.37 ÷ 255)- Range
- 0 to 17.37 V
- Unit
- V
In testing for 2017 to 2026.
Battery voltage after ignition GENESIS_BATTERY_V_AFTER_IGNITION
- Request
22 E0 01 - Service 22
DID E001 - Module
7E0 → 7E8 - Every
2 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 17.37 ÷ 255)- Range
- 0 to 17.37 V
- Unit
- V
In testing for 2017 to 2026.
Battery voltage after ignition GENESIS_BATTERY_V_AFTER_IGNITION_26
- Request
22 E0 01 - Service 22
DID E001 - Module
7E0 → 7E8 - Every
2 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 17.37 ÷ 255)- Range
- 0 to 17.37 V
- Unit
- V
In testing for 2017 to 2026.
Battery voltage, battery sensor GENESIS_BAT_V_BATSENS
Pelican can show this parameter as the starter battery voltage.
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val × 12.75 ÷ 255 + 6)- Range
- 0 to 18.75 V
- Unit
- V
In testing for 2017 to 2026.
Battery voltage, battery sensor GENESIS_BAT_V_BATSENS_7E0
Pelican can show this parameter as the starter battery voltage.
- Request
21 27 - Service 21
PID 27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 6)- Range
- 0 to 71.53 V
- Unit
- V
In testing for 2017 to 2026.
Battery voltage, battery sensor GENESIS_BAT_V_BATSENS_7E0_7E0_06
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 752 to 767 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 32 ÷ 65535)- Range
- 0 to 32 V
- Unit
- V
In testing for 2017 to 2026.
Battery voltage, battery sensor GENESIS_BAT_V_BATSENS_7E0_7E0_27
- Request
21 27 - Service 21
PID 27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 6)- Range
- 0 to 71.53 V
- Unit
- V
In testing for 2017 to 2026.
Battery work time total GENESIS_BATTERY_WORK_TIME_TOTAL_SEC
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 368 to 399 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295 s
- Unit
- s
In testing for 2017 to 2026.
Charge mode A/C maximum current limit GENESIS_CHARGE_MODE_AC_MAXIMUM_CURRENT_LIMIT
- Request
22 E0 01 - Service 22
DID E001 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 A
- Unit
- A
In testing for 2017 to 2026.
Charge mode DC maximum current limit GENESIS_CHARGE_MODE_DC_MAXIMUM_CURRENT_LIMIT
- Request
22 E0 01 - Service 22
DID E001 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 A
- Unit
- A
In testing for 2017 to 2026.
Charge mode DC target voltage GENESIS_CHARGE_MODE_DC_TARGET_VOLTAGE
- Request
22 E0 01 - Service 22
DID E001 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 2017 to 2026.
Charging? GENESIS_HV_CHARGING
Pelican can show this parameter as the charging state.
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bit 72 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
In testing for 2017 to 2026.
Control module voltage after ignition, raw count GENESIS_CONTROL_MODULE_VOLTAGE_AFTER_IGNITION
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Control module voltage, raw count GENESIS_CONTROL_MODULE_VOLTAGE
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Control pilot duty cycle GENESIS_HVBAT_CP_DUTY_CYCLE
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing
Bits 56 to 71 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Control pilot voltage GENESIS_HVBAT_CP_VOLTAGE
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2017 to 2026.
Coolant temperature sensor voltage GENESIS_COOLANT_T_SENSOR_VOLTAGE
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 184 to 199 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 0.0048828125)- Range
- 0 to 319.9951 V
- Unit
- V
In testing for 2017 to 2026.
Cumulative charge current GENESIS_CUM_CHG_CURRENT
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 240 to 271 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729 Ah
- Unit
- Ah
In testing for 2017 to 2026.
Cumulative charge current GENESIS_CUMULATIVE_CHARGE_CURRENT
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 240 to 271 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729.5 Ah
- Unit
- Ah
In testing for 2017 to 2026.
Cumulative DC charging time GENESIS_DC_CHRG_TIME
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 h
- Unit
- h
In testing for 2017 to 2026.
Cumulative discharge current GENESIS_CUM_DCHG_CURRENT
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 272 to 303 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729 Ah
- Unit
- Ah
In testing for 2017 to 2026.
Cumulative discharge current GENESIS_CUMULATIVE_DISCHARGE_CURRENT
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 272 to 303 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729.5 Ah
- Unit
- Ah
In testing for 2017 to 2026.
Cumulative energy charged GENESIS_CUM_ENERGY_CHARGED
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 304 to 335 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729 kWh
- Unit
- kWh
In testing for 2017 to 2026.
Cumulative energy charged GENESIS_CUMULATIVE_ENERGY_CHARGED
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 304 to 335 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729.5 kWh
- Unit
- kWh
In testing for 2017 to 2026.
Cumulative energy discharged GENESIS_CUM_ENERGY
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 336 to 367 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729 kWh
- Unit
- kWh
In testing for 2017 to 2026.
Cumulative energy discharged GENESIS_CUMULATIVE_ENERGY_DISCHARGED
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 336 to 367 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729.5 kWh
- Unit
- kWh
In testing for 2017 to 2026.
Current sensor narrow range, volts GENESIS_CURRENT_SENS_NARROW_RANGE
- Request
22 02 04 - Service 22
DID 0204 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 304 to 319 of the reply, 16 bits.
- Formula
(val × 26651 ÷ 21845000)- Range
- 0 to 79.95 V
- Unit
- V
In testing for 2017 to 2026.
Current sensor wide range, volts GENESIS_CURRENT_SENS_WIDE_RANGE
- Request
22 02 04 - Service 22
DID 0204 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 320 to 335 of the reply, 16 bits.
- Formula
(val × 26651 ÷ 21845000)- Range
- 0 to 79.95 A
- Unit
- A
In testing for 2017 to 2026.
DC charger current capability GENESIS_DC_CHARGER_CURRENT_CAPABILITY
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing
Bits 320 to 335 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 A
- Unit
- A
In testing for 2017 to 2026.
DC charging counter GENESIS_HVBAT_CHRG_CNT
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing
Bits 256 to 271 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
DC charging time, after plug-in GENESIS_DC_CHARGING_TIME_AFTER_PLUG_IN
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing
Bits 352 to 367 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 min
- Unit
- min
In testing for 2017 to 2026.
Desired alternator voltage duty cycle, battery sensor GENESIS_DES_ALTERNATOR_V
- Request
21 27 - Service 21
PID 27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
(val × 20 ÷ 13107)- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Discharge mode A/C maximum current limit GENESIS_DISCHARGE_MODE_AC_MAXIMUM_CURRENT_LIMIT
- Request
22 E0 01 - Service 22
DID E001 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 A
- Unit
- A
In testing for 2017 to 2026.
Discharge mode A/C target voltage GENESIS_DISCHARGE_MODE_V2L_AC_TARGET_VOLTAGE
- Request
22 E0 01 - Service 22
DID E001 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 V
- Unit
- V
In testing for 2017 to 2026.
Discharge mode DC maximum current limit GENESIS_DISCHARGE_MODE_DC_MAXIMUM_CURRENT_LIMIT
- Request
22 E0 01 - Service 22
DID E001 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 A
- Unit
- A
In testing for 2017 to 2026.
Electric oil pump, actual speed GENESIS_EOP_ACTUAL_SPEED
- Request
22 E0 09 - Service 22
DID E009 - Module
7E3 → 7EB - Every
1 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val × 20)- Range
- 0 to 5100 rpm
- Unit
- rpm
In testing for 2017 to 2026.
Electric oil pump, commanded speed GENESIS_EOP_COMMANDED_SPEED
- Request
22 E0 09 - Service 22
DID E009 - Module
7E3 → 7EB - Every
1 s - Testing
Bits 152 to 159 of the reply, 8 bits.
- Formula
(val × 20)- Range
- 0 to 5100 rpm
- Unit
- rpm
In testing for 2017 to 2026.
Electric oil pump, current DC GENESIS_EOP_CURRENT_DC
- Request
22 E0 09 - Service 22
DID E009 - Module
7E3 → 7EB - Every
1 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 A
- Unit
- A
In testing for 2017 to 2026.
Electric oil pump, current IQ GENESIS_EOP_CURRENT_IQ
- Request
22 E0 09 - Service 22
DID E009 - Module
7E3 → 7EB - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 A
- Unit
- A
In testing for 2017 to 2026.
Electric vehicle supply equipment, target current GENESIS_HVBAT_TARGET_CURR
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 A
- Unit
- A
In testing for 2017 to 2026.
Electric water pump, actual rotation speed GENESIS_EWP_ACTUAL_ROTATION_SPEED
- Request
22 E0 09 - Service 22
DID E009 - Module
7E3 → 7EB - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
(val × 24)- Range
- 0 to 6120 rpm
- Unit
- rpm
In testing for 2017 to 2026.
Electric water pump, commanded rotation speed GENESIS_EWP_COMMANDED_ROTATION_SPEED
- Request
22 E0 09 - Service 22
DID E009 - Module
7E3 → 7EB - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val × 24)- Range
- 0 to 6120 rpm
- Unit
- rpm
In testing for 2017 to 2026.
Electric water pump, current DC GENESIS_EWP_CURRENT_DC
- Request
22 E0 09 - Service 22
DID E009 - Module
7E3 → 7EB - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 A
- Unit
- A
In testing for 2017 to 2026.
Electric water pump, voltage DC GENESIS_EWP_VOLTAGE_DC
- Request
22 E0 09 - Service 22
DID E009 - Module
7E3 → 7EB - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2017 to 2026.
Gasoline particulate filter charge state GENESIS_CRUZ_GPF_CHG_ST
- Request
22 E0 09 - Service 22
DID E009 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 320 to 327 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Gasoline particulate filter inlet temperature sensor raw voltage GENESIS_CRUZ_GPF_INLET_T_SENS_RAW_V
- Request
22 E0 09 - Service 22
DID E009 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 21333 ÷ 4369000)- Range
- 0 to 319 V
- Unit
- V
In testing for 2017 to 2026.
Gasoline particulate filter outlet temperature sensor raw voltage GENESIS_CRUZ_GPF_OUTLET_T_SENS_V
- Request
22 E0 09 - Service 22
DID E009 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 272 to 287 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 21333 ÷ 4369000)- Range
- 0 to 319 V
- Unit
- V
In testing for 2017 to 2026.
High voltage battery, max current GENESIS_HVBAT_EV_MAX_CURRENT
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 A
- Unit
- A
In testing for 2017 to 2026.
High voltage battery, max voltage GENESIS_HVBAT_EV_MAX_VOLTAGE
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 2017 to 2026.
High voltage battery, state of charge GENESIS_HVBAT_SOC_VCMS
Pelican can show this parameter as the state of charge.
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
High voltage battery, target current GENESIS_HVBAT_BMS_TARGET_CURRENT
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 A
- Unit
- A
In testing for 2017 to 2026.
High voltage battery, target voltage GENESIS_HVBAT_BMS_TARGET_VOLTAGE
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 2017 to 2026.
High voltage battery, target voltage GENESIS_HVBAT_TARGET_VOLT
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 2017 to 2026.
High voltage battery, voltage GENESIS_HVBAT_HV_BATTERY_VOLTAGE
Pelican can show this parameter as the traction battery voltage.
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing
Bits 104 to 119 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 2017 to 2026.
HV battery charge GENESIS_HVBAT_SOC_DISP
Pelican can show this parameter as the state of charge.
- Request
22 01 05 - Service 22
DID 0105 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
HV battery charge GENESIS_HVBAT_SOC_DISP_7E4
Pelican can show this parameter as the state of charge.
- Request
22 01 05 - Service 22
DID 0105 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
(val × 0.5)- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
HV battery charge, dashboard GENESIS_HVBAT_SOC
Pelican can show this parameter as the state of charge.
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
HV battery charge, displayed GENESIS_HVBAT_SOC_DISP_V2
Pelican can show this parameter as the state of charge.
- Request
21 05 - Service 21
PID 05 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
HV battery charging GENESIS_HVBAT_CHARGING
Pelican can show this parameter as the charging state.
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bit 72 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2017 to 2026.
HV battery current GENESIS_HVBAT_CURR
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 A
- Unit
- A
In testing for 2017 to 2026.
HV battery DC voltage GENESIS_HVBAT_VDC
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 2017 to 2026.
HV battery fan GENESIS_HVBAT_FAN
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 224 to 231 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 Hz
- Unit
- Hz
In testing for 2017 to 2026.
HV battery fan status GENESIS_HVBAT_FAN_STATUS
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 216 to 223 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
HV battery health GENESIS_HVBAT_SOH_V2
Pelican can show this parameter as the state of health.
- Request
21 05 - Service 21
PID 05 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 200 to 215 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
HV battery heater 1 temperature GENESIS_HVBAT_HTR1_T
- Request
22 01 05 - Service 22
DID 0105 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -127 to 127 °C
- Unit
- °C
In testing for 2017 to 2026.
HV battery heater 2 temperature GENESIS_HVBAT_HTR2_T
- Request
22 01 05 - Service 22
DID 0105 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 192 to 199 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -127 to 127 °C
- Unit
- °C
In testing for 2017 to 2026.
HV battery max deterioration cell id GENESIS_HVBAT_DET_MAX_ID
- Request
22 01 05 - Service 22
DID 0105 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 216 to 223 of the reply, 8 bits.
- Formula
val- Range
- 0 to 98
- Unit
- Number
In testing for 2017 to 2026.
HV battery min deterioration GENESIS_HVBAT_DET_MIN_2
- Request
22 01 05 - Service 22
DID 0105 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
HV battery min deterioration cell id GENESIS_HVBAT_DET_MIN_ID
- Request
22 01 05 - Service 22
DID 0105 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 240 to 247 of the reply, 8 bits.
- Formula
val- Range
- 0 to 98
- Unit
- Number
In testing for 2017 to 2026.
HV battery remaining energy GENESIS_HVBAT_WH
- Request
22 01 05 - Service 22
DID 0105 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
(val × 2 ÷ 1000)- Range
- 0 to 100 kWh
- Unit
- kWh
In testing for 2017 to 2026.
HV battery state of health GENESIS_HVBAT_SOH
Pelican can show this parameter as the state of health.
- Request
22 01 05 - Service 22
DID 0105 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 200 to 215 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
HV battery temperature, maximum GENESIS_HVBAT_T_MAX
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 112 to 119 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -127 to 127 °C
- Unit
- °C
In testing for 2017 to 2026.
HV battery temperature, minimum GENESIS_HVBAT_T_MIN
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 120 to 127 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -127 to 127 °C
- Unit
- °C
In testing for 2017 to 2026.
HV battery temperature, module 1 GENESIS_HVBAT_MOD1_T
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 128 to 135 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -127 to 127 °C
- Unit
- °C
In testing for 2017 to 2026.
HV battery temperature, module 2 GENESIS_HVBAT_MOD2_T
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 136 to 143 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -127 to 127 °C
- Unit
- °C
In testing for 2017 to 2026.
HV battery temperature, module 3 GENESIS_HVBAT_MOD3_T
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 144 to 151 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -127 to 127 °C
- Unit
- °C
In testing for 2017 to 2026.
HV battery temperature, module 4 GENESIS_HVBAT_MOD4_T
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 152 to 159 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -127 to 127 °C
- Unit
- °C
In testing for 2017 to 2026.
HV cell voltage deviation GENESIS_HVBAT_C_DEV_V
- Request
22 01 05 - Service 22
DID 0105 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 160 to 167 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Ignition GENESIS_IGN
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bit 405 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2017 to 2026.
Intake air temperature sensor voltage GENESIS_IAT_SENSOR_VOLTAGE
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 248 to 263 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 0.0048828125)- Range
- 0 to 319.9951 V
- Unit
- V
In testing for 2017 to 2026.
Inverter capacitor voltage GENESIS_INVERTER_CAPACITOR_V
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 408 to 423 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 2017 to 2026.
Inverter capacitor voltage GENESIS_INVERTER_CAPACITOR_VOLTAGE
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 408 to 423 of the reply, 16 bits.
- Formula
val- Range
- 0 to 500 V
- Unit
- V
In testing for 2017 to 2026.
Inverter capacitor voltage GENESIS_INVRT_CV
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 408 to 423 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 2017 to 2026.
Isolation resistance GENESIS_ISO_R
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 456 to 471 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 kΩ
- Unit
- kΩ
In testing for 2017 to 2026.
Isolation resistance GENESIS_ISOLATION_RESISTANCE
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 456 to 471 of the reply, 16 bits.
- Formula
val- Range
- 0 to 1000 kΩ
- Unit
- kΩ
In testing for 2017 to 2026.
Least deteriorated cell number GENESIS_HVBAT_DET_MIN_CELL
- Request
21 05 - Service 21
PID 05 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 240 to 247 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Low-voltage dc-dc converter, input voltage GENESIS_2025_LDC_INPUT_VOLTAGE
- Request
22 E1 01 - Service 22
DID E101 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 2017 to 2026.
Low-voltage dc-dc converter, input voltage GENESIS_LDC_INPUT_VOLTAGE
- Request
22 E0 11 - Service 22
DID E011 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 2017 to 2026.
Low-voltage dc-dc converter, output current GENESIS_2025_LDC_OUTPUT_CURRENT
- Request
22 E1 01 - Service 22
DID E101 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val × 10 ÷ 1000)- Range
- 0 to 655.35 A
- Unit
- A
In testing for 2017 to 2026.
Low-voltage dc-dc converter, output current GENESIS_LDC_OUTPUT_CURRENT
- Request
22 E0 11 - Service 22
DID E011 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val × 10 ÷ 1000)- Range
- 0 to 655.35 A
- Unit
- A
In testing for 2017 to 2026.
Low-voltage dc-dc converter, output voltage GENESIS_2025_LDC_OUTPUT_VOLTAGE
- Request
22 E1 01 - Service 22
DID E101 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2026.
Low-voltage dc-dc converter, output voltage GENESIS_LDC_OUTPUT_VOLTAGE
- Request
22 E0 11 - Service 22
DID E011 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2026.
Low-voltage dc-dc converter, temperature GENESIS_2025_LDC_T
- Request
22 E1 01 - Service 22
DID E101 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val − 100)- Range
- -100 to 155 °C
- Unit
- °C
In testing for 2017 to 2026.
Low-voltage dc-dc converter, temperature GENESIS_LDC_T
- Request
22 E0 11 - Service 22
DID E011 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val − 100)- Range
- -100 to 155 °C
- Unit
- °C
In testing for 2017 to 2026.
Manifold pressure sensor voltage GENESIS_MAP_SENSOR_VOLTAGE
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 112 to 127 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 0.0048828125)- Range
- 0 to 319.9951 V
- Unit
- V
In testing for 2017 to 2026.
Maximum 48V battery voltage GENESIS_MAX_48V_BAT_V
- Request
22 02 04 - Service 22
DID 0204 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2017 to 2026.
Maximum cell voltage GENESIS_C_V_MAX
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Maximum cell voltage GENESIS_MAX_CELL_V
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Maximum cell voltage GENESIS_MAXIMUM_CELL_VOLTAGE
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
Maximum cell voltage id GENESIS_C_V_MAX_ID
The id of the cell with the highest voltage.
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Maximum cell voltage no GENESIS_MAXIMUM_CELL_VOLTAGE_NO
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
val- Range
- 0 to 98
- Unit
- Number
In testing for 2017 to 2026.
Maximum cell voltage no. GENESIS_MAX_CELL_V_NO
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Minimum 48V battery voltage GENESIS_MIN_48V_BAT_V
- Request
22 02 04 - Service 22
DID 0204 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2017 to 2026.
Minimum cell deterioration GENESIS_HVBAT_DET_MIN
- Request
21 05 - Service 21
PID 05 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 %
- Unit
- %
In testing for 2017 to 2026.
Minimum cell voltage GENESIS_C_V_MIN
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 200 to 207 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Minimum cell voltage GENESIS_MIN_CELL_V
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 200 to 207 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Minimum cell voltage GENESIS_MINIMUM_CELL_VOLTAGE
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 200 to 207 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
Minimum cell voltage id GENESIS_C_V_MIN_ID
The id of the cell with the lowest voltage.
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 208 to 215 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Minimum cell voltage no GENESIS_MINIMUM_CELL_VOLTAGE_NO
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 208 to 215 of the reply, 8 bits.
- Formula
val- Range
- 0 to 98
- Unit
- Number
In testing for 2017 to 2026.
Minimum cell voltage no. GENESIS_MIN_CELL_V_NO
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 208 to 215 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Most deteriorated cell number GENESIS_HVBAT_DET_MAX_CELL
- Request
21 05 - Service 21
PID 05 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 216 to 223 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Normal charge port GENESIS_NORMAL_CHARGE_PORT
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bit 74 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 2017 to 2026.
Normal charge port GENESIS_NORMAL_CHG_PORT
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bit 74 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2017 to 2026.
Normal charge port state GENESIS_HVBAT_PLUG_NORM
Pelican can show this parameter as the plug state.
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bit 74 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2017 to 2026.
Normal charging energy, total GENESIS_NORMAL_CHARGING_ENERGY_TOT
- Request
22 01 11 - Service 22
DID 0111 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 96 to 127 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295 kWh
- Unit
- kWh
In testing for 2017 to 2026.
Normal charging, count GENESIS_NORMAL_CHARGING_COUNT
- Request
22 01 11 - Service 22
DID 0111 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 32 to 63 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2017 to 2026.
On-board charger charger AC input current, RMS GENESIS_ON_BOARD_CHARGER
- Request
21 01 - Service 21
PID 01 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 200 to 207 of the reply, 8 bits.
- Formula
(val × 64 ÷ 25)- Range
- 0 to 652 A
- Unit
- A
In testing for 2017 to 2026.
On-board charger charger AC input voltage, instant GENESIS_ON_BOARD_CHARGER_CHARGER_V
- Request
21 01 - Service 21
PID 01 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 304 to 311 of the reply, 8 bits.
- Formula
(val × 64 ÷ 25 − 100)- Range
- -100 to 552 V
- Unit
- V
In testing for 2017 to 2026.
On-board charger charger AC input voltage, RMS GENESIS_ON_BOARD_CHARGER_V
- Request
21 01 - Service 21
PID 01 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val × 64 ÷ 25)- Range
- 0 to 652 V
- Unit
- V
In testing for 2017 to 2026.
On-board charger charger temperature a GENESIS_ON_BOARD_CHARGER_T
- Request
21 01 - Service 21
PID 01 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
(val − 100)- Range
- -100 to 155 °C
- Unit
- °C
In testing for 2017 to 2026.
On-board charger charger temperature b GENESIS_ON_BOARD_CHARGER_T_B
- Request
21 01 - Service 21
PID 01 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 336 to 343 of the reply, 8 bits.
- Formula
(val − 100)- Range
- -100 to 155 °C
- Unit
- °C
In testing for 2017 to 2026.
Proximity detection voltage GENESIS_HVBAT_PD_VOLTAGE
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing
Bits 88 to 103 of the reply, 16 bits.
- Formula
(val × 10 ÷ 10000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2026.
Quick charging energy, total GENESIS_QUICK_CHARGING_ENERGY_TOT
- Request
22 01 11 - Service 22
DID 0111 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 128 to 159 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295 kWh
- Unit
- kWh
In testing for 2017 to 2026.
Quick charging, count GENESIS_QUICK_CHARGING_COUNT
- Request
22 01 11 - Service 22
DID 0111 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 64 to 95 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2017 to 2026.
Rapid charge port GENESIS_RAPID_CHARGE_PORT
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bit 73 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2017 to 2026.
Rapid charge port GENESIS_RAPID_CHG_PORT
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bit 73 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2017 to 2026.
Rapid charge port state GENESIS_HVBAT_PLUG_RAPD
Pelican can show this parameter as the plug state.
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bit 73 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2017 to 2026.
Relative accelerator pedal position voltage GENESIS_RELATIVE_ACCELERATOR_PEDAL_POSITION_VOLTAGE
- Request
21 14 - Service 21
PID 14 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 112 to 127 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val ÷ 5)- Range
- -6553.6 to 6553.4 V
- Unit
- V
In testing for 2017 to 2026.
Response error from battery sensor flag, battery sensor GENESIS_RESPONSE_ERROR
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bit 178 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2017 to 2026.
State of charge GENESIS_BMS_SOC
- Request
22 01 01 - Service 22
DID 0101 - Module
7D4 → 7DC - Every
5 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
State of charge BMS GENESIS_ST_CHG_BMS
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127 %
- Unit
- %
In testing for 2017 to 2026.
Supply voltage GENESIS_SUPPLY_VOLTAGE
- Request
21 C0 - Service 21
PID C0 - Module
7E5 - Every
250 ms - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2017 to 2026.
System voltage GENESIS_SYSTEM_VOLTAGE
- Request
21 C0 - Service 21
PID C0 - Module
7E5 - Every
250 ms - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2017 to 2026.
Throttle position sensor voltage #1 GENESIS_THROTTLE_POSITION_SENSOR_VOLTAGE__1
- Request
21 14 - Service 21
PID 14 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 360 to 375 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 0.0012207031)- Range
- 0 to 79 V
- Unit
- V
In testing for 2017 to 2026.
Throttle position sensor voltage #2 GENESIS_THROTTLE_POSITION_SENSOR_VOLTAGE__2
- Request
21 14 - Service 21
PID 14 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 0.0012207031)- Range
- 0 to 79 V
- Unit
- V
In testing for 2017 to 2026.
Total charge current GENESIS_HVBAT_CHRG_TOT_C
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 240 to 271 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729 Ah
- Unit
- Ah
In testing for 2017 to 2026.
Total charge energy GENESIS_HVBAT_CHRG_TOT_E
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 304 to 335 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729 kWh
- Unit
- kWh
In testing for 2017 to 2026.
Total discharge current GENESIS_HVBAT_DSCH_TOT_C
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 272 to 303 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729 Ah
- Unit
- Ah
In testing for 2017 to 2026.
Total discharge energy GENESIS_HVBAT_DSCH_TOT_E
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 336 to 367 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729 kWh
- Unit
- kWh
In testing for 2017 to 2026.
Waste gate voltage GENESIS_WASTE_GATE_V
- Request
21 21 - Service 21
PID 21 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 392 to 407 of the reply, 16 bits.
- Formula
(val × 0.000152588)- Range
- 0 to 9.99 V
- Unit
- V
In testing for 2017 to 2026.
Wastegate position voltage GENESIS_WASTEGATE_POS_V
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 400 to 415 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val × 1.53 ÷ 10000)- Range
- -5.01 to 5.01 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Charging
400V relay on/off request GENESIS_400V_RELAY_ON_OFF_REQUEST
- Request
22 E0 04 - Service 22
DID E004 - Module
744 → 74C - Every
1 s - Testing
Bit 43 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2017 to 2026.
400V relay status GENESIS_400V_RELAY_STATUS
- Request
22 E0 04 - Service 22
DID E004 - Module
744 → 74C - Every
1 s - Testing
Bit 42 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2017 to 2026.
AC charging state GENESIS_AC_CHRG_STATE
- Request
22 E0 01 - Service 22
DID E001 - Module
744 → 74C - Every
1 s - Testing
Bit 141 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2017 to 2026.
AC inlet temperature 1 GENESIS_AC_INLET_T_1
- Request
22 E0 04 - Service 22
DID E004 - Module
744 → 74C - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2017 to 2026.
Auxiliary battery voltage GENESIS_AUX_BATTERY_VOLTAGE
- Request
22 E0 01 - Service 22
DID E001 - Module
744 → 74C - Every
1 s - Testing
Bits 88 to 103 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 V
- Unit
- V
In testing for 2017 to 2026.
Battery main relay status GENESIS_BATTERY_MAIN_RELAY_STATUS
- Request
22 E0 04 - Service 22
DID E004 - Module
744 → 74C - Every
1 s - Testing
Bit 37 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2017 to 2026.
Charging socket connected GENESIS_CHARGING_SOCKET_CONNECTED
- Request
22 E0 04 - Service 22
DID E004 - Module
744 → 74C - Every
1 s - Testing
Bit 38 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2017 to 2026.
DC charging state GENESIS_DC_CHRG_STATE
- Request
22 E0 01 - Service 22
DID E001 - Module
744 → 74C - Every
1 s - Testing
Bit 140 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2017 to 2026.
DC inlet temperature 1 GENESIS_DC_INLET_T_1
- Request
22 E0 04 - Service 22
DID E004 - Module
744 → 74C - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2017 to 2026.
DC inlet temperature 2 GENESIS_DC_INLET_T_2
- Request
22 E0 04 - Service 22
DID E004 - Module
744 → 74C - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2017 to 2026.
Electric vehicle supply equipment, current GENESIS_EVSE_C
- Request
22 E0 02 - Service 22
DID E002 - Module
744 → 74C - Every
250 ms - Testing
Bits 152 to 167 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 A
- Unit
- A
In testing for 2017 to 2026.
Electric vehicle supply equipment, current, max GENESIS_EVSE_MAXIMUM_CURRENT_VALUE
- Request
22 E0 02 - Service 22
DID E002 - Module
744 → 74C - Every
250 ms - Testing
Bits 88 to 103 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 A
- Unit
- A
In testing for 2017 to 2026.
Electric vehicle supply equipment, current, min GENESIS_EVSE_MINIMUM_CURRENT_VALUE
- Request
22 E0 02 - Service 22
DID E002 - Module
744 → 74C - Every
250 ms - Testing
Bits 120 to 135 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 A
- Unit
- A
In testing for 2017 to 2026.
Electric vehicle supply equipment, power, delivered GENESIS_EVSE_DELIVERED_POWER_VALUE
- Request
22 E0 02 - Service 22
DID E002 - Module
744 → 74C - Every
250 ms - Testing
Bits 184 to 199 of the reply, 16 bits.
- Formula
(val × 10 ÷ 1000)- Range
- 0 to 655.35 kWh
- Unit
- kWh
In testing for 2017 to 2026.
Electric vehicle supply equipment, power, main GENESIS_EVSE_MAIN_POWER
- Request
22 E0 02 - Service 22
DID E002 - Module
744 → 74C - Every
250 ms - Testing
Bits 216 to 223 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 kW
- Unit
- kW
In testing for 2017 to 2026.
Electric vehicle supply equipment, power, max GENESIS_EVSE_MAXIMUM_POWER_VALUE
- Request
22 E0 02 - Service 22
DID E002 - Module
744 → 74C - Every
250 ms - Testing
Bits 200 to 215 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 W
- Unit
- W
In testing for 2017 to 2026.
Electric vehicle supply equipment, regulation tolerance GENESIS_EVSE_CURRENT_REGULATION_TOLERANCE_VALUE
- Request
22 E0 02 - Service 22
DID E002 - Module
744 → 74C - Every
250 ms - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 A
- Unit
- A
In testing for 2017 to 2026.
Electric vehicle supply equipment, voltage GENESIS_EVSE_V
- Request
22 E0 02 - Service 22
DID E002 - Module
744 → 74C - Every
250 ms - Testing
Bits 136 to 151 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 2017 to 2026.
Electric vehicle supply equipment, voltage, max GENESIS_EVSE_MAXIMUM_VOLTAGE_VALUE
- Request
22 E0 02 - Service 22
DID E002 - Module
744 → 74C - Every
250 ms - Testing
Bits 72 to 87 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 2017 to 2026.
Electric vehicle supply equipment, voltage, min GENESIS_EVSE_MINIMUM_VOLTAGE_VALUE
- Request
22 E0 02 - Service 22
DID E002 - Module
744 → 74C - Every
250 ms - Testing
Bits 104 to 119 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 2017 to 2026.
Estimated charging power GENESIS_ESTIMATED_CHRG_POWER
- Request
22 E0 01 - Service 22
DID E001 - Module
744 → 74C - Every
1 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
(val × 10 − 50)- Range
- -50 to 655300 W
- Unit
- W
In testing for 2017 to 2026.
On-board charger, AC current a GENESIS_OBC_AC_CURRENT_A_RMS
- Request
22 E0 02 - Service 22
DID E002 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 104 to 119 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 A
- Unit
- A
In testing for 2017 to 2026.
On-board charger, AC current b GENESIS_OBC_AC_CURRENT_B_RMS
- Request
22 E0 02 - Service 22
DID E002 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 120 to 135 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 A
- Unit
- A
In testing for 2017 to 2026.
On-board charger, AC frequency GENESIS_OBC_AC_FREQUENCY
- Request
22 E0 02 - Service 22
DID E002 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 Hz
- Unit
- Hz
In testing for 2017 to 2026.
On-board charger, AC input current sensor a signal voltage GENESIS_OBC_AC_INPUT_CURRENT_SENSOR_A_SIGNAL_VOLTAGE
- Request
22 E0 02 - Service 22
DID E002 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 296 to 311 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 V
- Unit
- V
In testing for 2017 to 2026.
On-board charger, AC input current sensor b signal voltage GENESIS_OBC_AC_INPUT_CURRENT_SENSOR_B_SIGNAL_VOLTAGE
- Request
22 E0 02 - Service 22
DID E002 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 312 to 327 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 V
- Unit
- V
In testing for 2017 to 2026.
On-board charger, AC total current GENESIS_OBC_AC_TOTAL_CURRENT_RMS
- Request
22 E0 02 - Service 22
DID E002 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 88 to 103 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 A
- Unit
- A
In testing for 2017 to 2026.
On-board charger, AC voltage a GENESIS_OBC_AC_VOLTAGE_A_RMS
- Request
22 E0 02 - Service 22
DID E002 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 2017 to 2026.
On-board charger, AC voltage b GENESIS_OBC_AC_VOLTAGE_B_RMS
- Request
22 E0 02 - Service 22
DID E002 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 2017 to 2026.
On-board charger, charge mode DC target current GENESIS_OBC_CHARGE_MODE_DC_TARGET_CURRENT
- Request
22 E0 03 - Service 22
DID E003 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 A
- Unit
- A
In testing for 2017 to 2026.
On-board charger, charge mode DC target voltage GENESIS_OBC_CHARGE_MODE_DC_TARGET_VOLTAGE
- Request
22 E0 03 - Service 22
DID E003 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 2017 to 2026.
On-board charger, charging AC current GENESIS_OBC_CHRG_AC_CURRENT
- Request
22 E0 01 - Service 22
DID E001 - Module
744 → 74C - Every
1 s - Testing
Bits 184 to 199 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 A
- Unit
- A
In testing for 2017 to 2026.
On-board charger, charging AC voltage GENESIS_OBC_CHRG_AC_VOLTAGE
- Request
22 E0 01 - Service 22
DID E001 - Module
744 → 74C - Every
1 s - Testing
Bits 200 to 207 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 V
- Unit
- V
In testing for 2017 to 2026.
On-board charger, charging DC current GENESIS_OBC_CHRG_DC_CURRENT
- Request
22 E0 01 - Service 22
DID E001 - Module
744 → 74C - Every
1 s - Testing
Bits 168 to 183 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 A
- Unit
- A
In testing for 2017 to 2026.
On-board charger, charging DC voltage GENESIS_OBC_CHRG_DC_VOLTAGE
- Request
22 E0 01 - Service 22
DID E001 - Module
744 → 74C - Every
1 s - Testing
Bits 152 to 167 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 2017 to 2026.
On-board charger, DC current a GENESIS_OBC_DC_CURRENT_A_RMS
- Request
22 E0 02 - Service 22
DID E002 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 184 to 199 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 A
- Unit
- A
In testing for 2017 to 2026.
On-board charger, DC current b GENESIS_OBC_DC_CURRENT_B_RMS
- Request
22 E0 02 - Service 22
DID E002 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 200 to 215 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 A
- Unit
- A
In testing for 2017 to 2026.
On-board charger, DC current total GENESIS_OBC_DC_CURRENT_TOTAL_RMS
- Request
22 E0 02 - Service 22
DID E002 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 168 to 183 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 A
- Unit
- A
In testing for 2017 to 2026.
On-board charger, DC voltage GENESIS_OBC_DC_VOLTAGE
- Request
22 E0 02 - Service 22
DID E002 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 152 to 167 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 2017 to 2026.
On-board charger, discharging AC current GENESIS_OBC_DCHRG_AC_CURRENT
- Request
22 E0 01 - Service 22
DID E001 - Module
744 → 74C - Every
1 s - Testing
Bits 216 to 223 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 A
- Unit
- A
In testing for 2017 to 2026.
On-board charger, discharging DC current GENESIS_OBC_DCHRG_DC_CURRENT
- Request
22 E0 01 - Service 22
DID E001 - Module
744 → 74C - Every
1 s - Testing
Bits 208 to 215 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 A
- Unit
- A
In testing for 2017 to 2026.
On-board charger, temperature a GENESIS_OBC_T_A
- Request
22 E0 02 - Service 22
DID E002 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 216 to 223 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2017 to 2026.
On-board charger, temperature b GENESIS_OBC_T_B
- Request
22 E0 02 - Service 22
DID E002 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 224 to 231 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2017 to 2026.
Battery › Modules › 001
HV battery module 001 voltage GENESIS_HVBAT_CMU001_VOLT
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 001 voltage GENESIS_HVBAT_CMU001_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 001 voltage GENESIS_HVBAT_CMU001_VOLT_V2
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 002
HV battery module 002 voltage GENESIS_HVBAT_CMU002_VOLT
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 002 voltage GENESIS_HVBAT_CMU002_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 002 voltage GENESIS_HVBAT_CMU002_VOLT_V2
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 003
HV battery module 003 voltage GENESIS_HVBAT_CMU003_VOLT
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 003 voltage GENESIS_HVBAT_CMU003_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 003 voltage GENESIS_HVBAT_CMU003_VOLT_V2
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 004
HV battery module 004 voltage GENESIS_HVBAT_CMU004_VOLT
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 004 voltage GENESIS_HVBAT_CMU004_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 004 voltage GENESIS_HVBAT_CMU004_VOLT_V2
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 005
HV battery module 005 voltage GENESIS_HVBAT_CMU005_VOLT
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 005 voltage GENESIS_HVBAT_CMU005_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 005 voltage GENESIS_HVBAT_CMU005_VOLT_V2
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 006
HV battery module 006 voltage GENESIS_HVBAT_CMU006_VOLT
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 006 voltage GENESIS_HVBAT_CMU006_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 006 voltage GENESIS_HVBAT_CMU006_VOLT_V2
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 007
HV battery module 007 voltage GENESIS_HVBAT_CMU007_VOLT
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 007 voltage GENESIS_HVBAT_CMU007_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 007 voltage GENESIS_HVBAT_CMU007_VOLT_V2
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 008
HV battery module 008 voltage GENESIS_HVBAT_CMU008_VOLT
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 008 voltage GENESIS_HVBAT_CMU008_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 008 voltage GENESIS_HVBAT_CMU008_VOLT_V2
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 009
HV battery module 009 voltage GENESIS_HVBAT_CMU009_VOLT
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 009 voltage GENESIS_HVBAT_CMU009_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 009 voltage GENESIS_HVBAT_CMU009_VOLT_V2
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 010
HV battery module 010 voltage GENESIS_HVBAT_CMU010_VOLT
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 010 voltage GENESIS_HVBAT_CMU010_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 010 voltage GENESIS_HVBAT_CMU010_VOLT_V2
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 011
HV battery module 011 voltage GENESIS_HVBAT_CMU011_VOLT
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 011 voltage GENESIS_HVBAT_CMU011_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 011 voltage GENESIS_HVBAT_CMU011_VOLT_V2
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 012
HV battery module 012 voltage GENESIS_HVBAT_CMU012_VOLT
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 012 voltage GENESIS_HVBAT_CMU012_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 012 voltage GENESIS_HVBAT_CMU012_VOLT_V2
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 013
HV battery module 013 voltage GENESIS_HVBAT_CMU013_VOLT
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 013 voltage GENESIS_HVBAT_CMU013_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 013 voltage GENESIS_HVBAT_CMU013_VOLT_V2
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 014
HV battery module 014 voltage GENESIS_HVBAT_CMU014_VOLT
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 014 voltage GENESIS_HVBAT_CMU014_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 014 voltage GENESIS_HVBAT_CMU014_VOLT_V2
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 015
HV battery module 015 voltage GENESIS_HVBAT_CMU015_VOLT
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 144 to 151 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 015 voltage GENESIS_HVBAT_CMU015_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 144 to 151 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 015 voltage GENESIS_HVBAT_CMU015_VOLT_V2
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 144 to 151 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 016
HV battery module 016 voltage GENESIS_HVBAT_CMU016_VOLT
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 152 to 159 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 016 voltage GENESIS_HVBAT_CMU016_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 152 to 159 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 016 voltage GENESIS_HVBAT_CMU016_VOLT_V2
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 152 to 159 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 017
HV battery module 017 voltage GENESIS_HVBAT_CMU017_VOLT
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 160 to 167 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 017 voltage GENESIS_HVBAT_CMU017_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 160 to 167 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 017 voltage GENESIS_HVBAT_CMU017_VOLT_V2
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 160 to 167 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 018
HV battery module 018 voltage GENESIS_HVBAT_CMU018_VOLT
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 018 voltage GENESIS_HVBAT_CMU018_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 018 voltage GENESIS_HVBAT_CMU018_VOLT_V2
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 019
HV battery module 019 voltage GENESIS_HVBAT_CMU019_VOLT
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 019 voltage GENESIS_HVBAT_CMU019_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 019 voltage GENESIS_HVBAT_CMU019_VOLT_V2
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 020
HV battery module 020 voltage GENESIS_HVBAT_CMU020_VOLT
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 020 voltage GENESIS_HVBAT_CMU020_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 020 voltage GENESIS_HVBAT_CMU020_VOLT_V2
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 021
HV battery module 021 voltage GENESIS_HVBAT_CMU021_VOLT
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 021 voltage GENESIS_HVBAT_CMU021_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 021 voltage GENESIS_HVBAT_CMU021_VOLT_V2
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 022
HV battery module 022 voltage GENESIS_HVBAT_CMU022_VOLT
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 200 to 207 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 022 voltage GENESIS_HVBAT_CMU022_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 200 to 207 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 022 voltage GENESIS_HVBAT_CMU022_VOLT_V2
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 200 to 207 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 023
HV battery module 023 voltage GENESIS_HVBAT_CMU023_VOLT
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 208 to 215 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 023 voltage GENESIS_HVBAT_CMU023_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 208 to 215 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 023 voltage GENESIS_HVBAT_CMU023_VOLT_V2
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 208 to 215 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 024
HV battery module 024 voltage GENESIS_HVBAT_CMU024_VOLT
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 216 to 223 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 024 voltage GENESIS_HVBAT_CMU024_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 216 to 223 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 024 voltage GENESIS_HVBAT_CMU024_VOLT_V2
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 216 to 223 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 025
HV battery module 025 voltage GENESIS_HVBAT_CMU025_VOLT
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 224 to 231 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 025 voltage GENESIS_HVBAT_CMU025_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 224 to 231 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 025 voltage GENESIS_HVBAT_CMU025_VOLT_V2
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 224 to 231 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 026
HV battery module 026 voltage GENESIS_HVBAT_CMU026_VOLT
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 232 to 239 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 026 voltage GENESIS_HVBAT_CMU026_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 232 to 239 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 026 voltage GENESIS_HVBAT_CMU026_VOLT_V2
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 232 to 239 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 027
HV battery module 027 voltage GENESIS_HVBAT_CMU027_VOLT
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 240 to 247 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 027 voltage GENESIS_HVBAT_CMU027_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 240 to 247 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 027 voltage GENESIS_HVBAT_CMU027_VOLT_V2
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 240 to 247 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 028
HV battery module 028 voltage GENESIS_HVBAT_CMU028_VOLT
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 028 voltage GENESIS_HVBAT_CMU028_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 028 voltage GENESIS_HVBAT_CMU028_VOLT_V2
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 029
HV battery module 029 voltage GENESIS_HVBAT_CMU029_VOLT
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 256 to 263 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 029 voltage GENESIS_HVBAT_CMU029_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 256 to 263 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 029 voltage GENESIS_HVBAT_CMU029_VOLT_V2
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 256 to 263 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 030
HV battery module 030 voltage GENESIS_HVBAT_CMU030_VOLT
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 264 to 271 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 030 voltage GENESIS_HVBAT_CMU030_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 264 to 271 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 030 voltage GENESIS_HVBAT_CMU030_VOLT_V2
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 264 to 271 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 031
HV battery module 031 voltage GENESIS_HVBAT_CMU031_VOLT
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 272 to 279 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 031 voltage GENESIS_HVBAT_CMU031_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 272 to 279 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 031 voltage GENESIS_HVBAT_CMU031_VOLT_V2
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 272 to 279 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 032
HV battery module 032 voltage GENESIS_HVBAT_CMU032_VOLT
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 280 to 287 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 032 voltage GENESIS_HVBAT_CMU032_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 280 to 287 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 032 voltage GENESIS_HVBAT_CMU032_VOLT_V2
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 280 to 287 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 033
HV battery module 033 voltage GENESIS_HVBAT_CMU033_VOLT
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 033 voltage GENESIS_HVBAT_CMU033_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 033 voltage GENESIS_HVBAT_CMU033_VOLT_V2
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 034
HV battery module 034 voltage GENESIS_HVBAT_CMU034_VOLT
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 034 voltage GENESIS_HVBAT_CMU034_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 034 voltage GENESIS_HVBAT_CMU034_VOLT_V2
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 035
HV battery module 035 voltage GENESIS_HVBAT_CMU035_VOLT
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 035 voltage GENESIS_HVBAT_CMU035_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 035 voltage GENESIS_HVBAT_CMU035_VOLT_V2
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 036
HV battery module 036 voltage GENESIS_HVBAT_CMU036_VOLT
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 036 voltage GENESIS_HVBAT_CMU036_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 036 voltage GENESIS_HVBAT_CMU036_VOLT_V2
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 037
HV battery module 037 voltage GENESIS_HVBAT_CMU037_VOLT
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 037 voltage GENESIS_HVBAT_CMU037_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 037 voltage GENESIS_HVBAT_CMU037_VOLT_V2
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 038
HV battery module 038 voltage GENESIS_HVBAT_CMU038_VOLT
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 038 voltage GENESIS_HVBAT_CMU038_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 038 voltage GENESIS_HVBAT_CMU038_VOLT_V2
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 039
HV battery module 039 voltage GENESIS_HVBAT_CMU039_VOLT
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 039 voltage GENESIS_HVBAT_CMU039_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 039 voltage GENESIS_HVBAT_CMU039_VOLT_V2
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 040
HV battery module 040 voltage GENESIS_HVBAT_CMU040_VOLT
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 040 voltage GENESIS_HVBAT_CMU040_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 040 voltage GENESIS_HVBAT_CMU040_VOLT_V2
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 041
HV battery module 041 voltage GENESIS_HVBAT_CMU041_VOLT
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 041 voltage GENESIS_HVBAT_CMU041_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 041 voltage GENESIS_HVBAT_CMU041_VOLT_V2
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 042
HV battery module 042 voltage GENESIS_HVBAT_CMU042_VOLT
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 042 voltage GENESIS_HVBAT_CMU042_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 042 voltage GENESIS_HVBAT_CMU042_VOLT_V2
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 043
HV battery module 043 voltage GENESIS_HVBAT_CMU043_VOLT
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 043 voltage GENESIS_HVBAT_CMU043_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 043 voltage GENESIS_HVBAT_CMU043_VOLT_V2
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 044
HV battery module 044 voltage GENESIS_HVBAT_CMU044_VOLT
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 044 voltage GENESIS_HVBAT_CMU044_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 044 voltage GENESIS_HVBAT_CMU044_VOLT_V2
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 045
HV battery module 045 voltage GENESIS_HVBAT_CMU045_VOLT
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 045 voltage GENESIS_HVBAT_CMU045_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 045 voltage GENESIS_HVBAT_CMU045_VOLT_V2
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 046
HV battery module 046 voltage GENESIS_HVBAT_CMU046_VOLT
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 046 voltage GENESIS_HVBAT_CMU046_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 046 voltage GENESIS_HVBAT_CMU046_VOLT_V2
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 047
HV battery module 047 voltage GENESIS_HVBAT_CMU047_VOLT
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 144 to 151 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 047 voltage GENESIS_HVBAT_CMU047_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 144 to 151 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 047 voltage GENESIS_HVBAT_CMU047_VOLT_V2
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 144 to 151 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 048
HV battery module 048 voltage GENESIS_HVBAT_CMU048_VOLT
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 152 to 159 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 048 voltage GENESIS_HVBAT_CMU048_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 152 to 159 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 048 voltage GENESIS_HVBAT_CMU048_VOLT_V2
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 152 to 159 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 049
HV battery module 049 voltage GENESIS_HVBAT_CMU049_VOLT
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 160 to 167 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 049 voltage GENESIS_HVBAT_CMU049_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 160 to 167 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 049 voltage GENESIS_HVBAT_CMU049_VOLT_V2
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 160 to 167 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 050
HV battery module 050 voltage GENESIS_HVBAT_CMU050_VOLT
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 050 voltage GENESIS_HVBAT_CMU050_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 050 voltage GENESIS_HVBAT_CMU050_VOLT_V2
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 051
HV battery module 051 voltage GENESIS_HVBAT_CMU051_VOLT
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 051 voltage GENESIS_HVBAT_CMU051_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 051 voltage GENESIS_HVBAT_CMU051_VOLT_V2
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 052
HV battery module 052 voltage GENESIS_HVBAT_CMU052_VOLT
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 052 voltage GENESIS_HVBAT_CMU052_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 052 voltage GENESIS_HVBAT_CMU052_VOLT_V2
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 053
HV battery module 053 voltage GENESIS_HVBAT_CMU053_VOLT
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 053 voltage GENESIS_HVBAT_CMU053_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 053 voltage GENESIS_HVBAT_CMU053_VOLT_V2
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 054
HV battery module 054 voltage GENESIS_HVBAT_CMU054_VOLT
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 200 to 207 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 054 voltage GENESIS_HVBAT_CMU054_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 200 to 207 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 054 voltage GENESIS_HVBAT_CMU054_VOLT_V2
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 200 to 207 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 055
HV battery module 055 voltage GENESIS_HVBAT_CMU055_VOLT
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 208 to 215 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 055 voltage GENESIS_HVBAT_CMU055_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 208 to 215 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 055 voltage GENESIS_HVBAT_CMU055_VOLT_V2
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 208 to 215 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 056
HV battery module 056 voltage GENESIS_HVBAT_CMU056_VOLT
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 216 to 223 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 056 voltage GENESIS_HVBAT_CMU056_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 216 to 223 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 056 voltage GENESIS_HVBAT_CMU056_VOLT_V2
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 216 to 223 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 057
HV battery module 057 voltage GENESIS_HVBAT_CMU057_VOLT
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 224 to 231 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 057 voltage GENESIS_HVBAT_CMU057_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 224 to 231 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 057 voltage GENESIS_HVBAT_CMU057_VOLT_V2
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 224 to 231 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 058
HV battery module 058 voltage GENESIS_HVBAT_CMU058_VOLT
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 232 to 239 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 058 voltage GENESIS_HVBAT_CMU058_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 232 to 239 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 058 voltage GENESIS_HVBAT_CMU058_VOLT_V2
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 232 to 239 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 059
HV battery module 059 voltage GENESIS_HVBAT_CMU059_VOLT
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 240 to 247 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 059 voltage GENESIS_HVBAT_CMU059_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 240 to 247 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 059 voltage GENESIS_HVBAT_CMU059_VOLT_V2
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 240 to 247 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 060
HV battery module 060 voltage GENESIS_HVBAT_CMU060_VOLT
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 060 voltage GENESIS_HVBAT_CMU060_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 060 voltage GENESIS_HVBAT_CMU060_VOLT_V2
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 061
HV battery module 061 voltage GENESIS_HVBAT_CMU061_VOLT
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 256 to 263 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 061 voltage GENESIS_HVBAT_CMU061_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 256 to 263 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 061 voltage GENESIS_HVBAT_CMU061_VOLT_V2
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 256 to 263 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 062
HV battery module 062 voltage GENESIS_HVBAT_CMU062_VOLT
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 264 to 271 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 062 voltage GENESIS_HVBAT_CMU062_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 264 to 271 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 062 voltage GENESIS_HVBAT_CMU062_VOLT_V2
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 264 to 271 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 063
HV battery module 063 voltage GENESIS_HVBAT_CMU063_VOLT
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 272 to 279 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 063 voltage GENESIS_HVBAT_CMU063_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 272 to 279 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 063 voltage GENESIS_HVBAT_CMU063_VOLT_V2
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 272 to 279 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 064
HV battery module 064 voltage GENESIS_HVBAT_CMU064_VOLT
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 280 to 287 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 064 voltage GENESIS_HVBAT_CMU064_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 280 to 287 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 064 voltage GENESIS_HVBAT_CMU064_VOLT_V2
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 280 to 287 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 065
HV battery module 065 voltage GENESIS_HVBAT_CMU065_VOLT
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 065 voltage GENESIS_HVBAT_CMU065_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 065 voltage GENESIS_HVBAT_CMU065_VOLT_V2
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 066
HV battery module 066 voltage GENESIS_HVBAT_CMU066_VOLT
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 066 voltage GENESIS_HVBAT_CMU066_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 066 voltage GENESIS_HVBAT_CMU066_VOLT_V2
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 067
HV battery module 067 voltage GENESIS_HVBAT_CMU067_VOLT
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 067 voltage GENESIS_HVBAT_CMU067_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 067 voltage GENESIS_HVBAT_CMU067_VOLT_V2
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 068
HV battery module 068 voltage GENESIS_HVBAT_CMU068_VOLT
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 068 voltage GENESIS_HVBAT_CMU068_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 068 voltage GENESIS_HVBAT_CMU068_VOLT_V2
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 069
HV battery module 069 voltage GENESIS_HVBAT_CMU069_VOLT
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 069 voltage GENESIS_HVBAT_CMU069_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 069 voltage GENESIS_HVBAT_CMU069_VOLT_V2
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 070
HV battery module 070 voltage GENESIS_HVBAT_CMU070_VOLT
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 070 voltage GENESIS_HVBAT_CMU070_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 070 voltage GENESIS_HVBAT_CMU070_VOLT_V2
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 071
HV battery module 071 voltage GENESIS_HVBAT_CMU071_VOLT
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 071 voltage GENESIS_HVBAT_CMU071_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 071 voltage GENESIS_HVBAT_CMU071_VOLT_V2
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 072
HV battery module 072 voltage GENESIS_HVBAT_CMU072_VOLT
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 072 voltage GENESIS_HVBAT_CMU072_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 072 voltage GENESIS_HVBAT_CMU072_VOLT_V2
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 073
HV battery module 073 voltage GENESIS_HVBAT_CMU073_VOLT
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 073 voltage GENESIS_HVBAT_CMU073_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 073 voltage GENESIS_HVBAT_CMU073_VOLT_V2
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 074
HV battery module 074 voltage GENESIS_HVBAT_CMU074_VOLT
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 074 voltage GENESIS_HVBAT_CMU074_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 074 voltage GENESIS_HVBAT_CMU074_VOLT_V2
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 075
HV battery module 075 voltage GENESIS_HVBAT_CMU075_VOLT
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 075 voltage GENESIS_HVBAT_CMU075_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 075 voltage GENESIS_HVBAT_CMU075_VOLT_V2
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 076
HV battery module 076 voltage GENESIS_HVBAT_CMU076_VOLT
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 076 voltage GENESIS_HVBAT_CMU076_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 076 voltage GENESIS_HVBAT_CMU076_VOLT_V2
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 077
HV battery module 077 voltage GENESIS_HVBAT_CMU077_VOLT
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 077 voltage GENESIS_HVBAT_CMU077_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 077 voltage GENESIS_HVBAT_CMU077_VOLT_V2
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 078
HV battery module 078 voltage GENESIS_HVBAT_CMU078_VOLT
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 078 voltage GENESIS_HVBAT_CMU078_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 078 voltage GENESIS_HVBAT_CMU078_VOLT_V2
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 079
HV battery module 079 voltage GENESIS_HVBAT_CMU079_VOLT
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 144 to 151 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 079 voltage GENESIS_HVBAT_CMU079_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 144 to 151 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 079 voltage GENESIS_HVBAT_CMU079_VOLT_V2
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 144 to 151 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 080
HV battery module 080 voltage GENESIS_HVBAT_CMU080_VOLT
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 152 to 159 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 080 voltage GENESIS_HVBAT_CMU080_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 152 to 159 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 080 voltage GENESIS_HVBAT_CMU080_VOLT_V2
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 152 to 159 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 081
HV battery module 081 voltage GENESIS_HVBAT_CMU081_VOLT
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 160 to 167 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 081 voltage GENESIS_HVBAT_CMU081_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 160 to 167 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 081 voltage GENESIS_HVBAT_CMU081_VOLT_V2
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 160 to 167 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 082
HV battery module 082 voltage GENESIS_HVBAT_CMU082_VOLT
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 082 voltage GENESIS_HVBAT_CMU082_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 082 voltage GENESIS_HVBAT_CMU082_VOLT_V2
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 083
HV battery module 083 voltage GENESIS_HVBAT_CMU083_VOLT
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 083 voltage GENESIS_HVBAT_CMU083_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 083 voltage GENESIS_HVBAT_CMU083_VOLT_V2
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 084
HV battery module 084 voltage GENESIS_HVBAT_CMU084_VOLT
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 084 voltage GENESIS_HVBAT_CMU084_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 084 voltage GENESIS_HVBAT_CMU084_VOLT_V2
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 085
HV battery module 085 voltage GENESIS_HVBAT_CMU085_VOLT
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 085 voltage GENESIS_HVBAT_CMU085_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 085 voltage GENESIS_HVBAT_CMU085_VOLT_V2
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 086
HV battery module 086 voltage GENESIS_HVBAT_CMU086_VOLT
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 200 to 207 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 086 voltage GENESIS_HVBAT_CMU086_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 200 to 207 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 086 voltage GENESIS_HVBAT_CMU086_VOLT_V2
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 200 to 207 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 087
HV battery module 087 voltage GENESIS_HVBAT_CMU087_VOLT
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 208 to 215 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 087 voltage GENESIS_HVBAT_CMU087_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 208 to 215 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 087 voltage GENESIS_HVBAT_CMU087_VOLT_V2
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 208 to 215 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 088
HV battery module 088 voltage GENESIS_HVBAT_CMU088_VOLT
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 216 to 223 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 088 voltage GENESIS_HVBAT_CMU088_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 216 to 223 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 088 voltage GENESIS_HVBAT_CMU088_VOLT_V2
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 216 to 223 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 089
HV battery module 089 voltage GENESIS_HVBAT_CMU089_VOLT
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 224 to 231 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 089 voltage GENESIS_HVBAT_CMU089_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 224 to 231 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 089 voltage GENESIS_HVBAT_CMU089_VOLT_V2
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 224 to 231 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 090
HV battery module 090 voltage GENESIS_HVBAT_CMU090_VOLT
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 232 to 239 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 090 voltage GENESIS_HVBAT_CMU090_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 232 to 239 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 090 voltage GENESIS_HVBAT_CMU090_VOLT_V2
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 232 to 239 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 091
HV battery module 091 voltage GENESIS_HVBAT_CMU091_VOLT
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 240 to 247 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 091 voltage GENESIS_HVBAT_CMU091_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 240 to 247 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 091 voltage GENESIS_HVBAT_CMU091_VOLT_V2
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 240 to 247 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 092
HV battery module 092 voltage GENESIS_HVBAT_CMU092_VOLT
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 092 voltage GENESIS_HVBAT_CMU092_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 092 voltage GENESIS_HVBAT_CMU092_VOLT_V2
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 093
HV battery module 093 voltage GENESIS_HVBAT_CMU093_VOLT
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 256 to 263 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 093 voltage GENESIS_HVBAT_CMU093_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 256 to 263 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 093 voltage GENESIS_HVBAT_CMU093_VOLT_V2
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 256 to 263 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 094
HV battery module 094 voltage GENESIS_HVBAT_CMU094_VOLT
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 264 to 271 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 094 voltage GENESIS_HVBAT_CMU094_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 264 to 271 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 094 voltage GENESIS_HVBAT_CMU094_VOLT_V2
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 264 to 271 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 095
HV battery module 095 voltage GENESIS_HVBAT_CMU095_VOLT
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 272 to 279 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 095 voltage GENESIS_HVBAT_CMU095_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 272 to 279 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 095 voltage GENESIS_HVBAT_CMU095_VOLT_V2
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 272 to 279 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 096
HV battery module 096 voltage GENESIS_HVBAT_CMU096_VOLT
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 280 to 287 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 096 voltage GENESIS_HVBAT_CMU096_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 280 to 287 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 096 voltage GENESIS_HVBAT_CMU096_VOLT_V2
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 280 to 287 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 097
HV battery module 097 voltage GENESIS_HVBAT_CMU097_VOLT
- Request
22 01 05 - Service 22
DID 0105 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 272 to 279 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 097 voltage GENESIS_HVBAT_CMU097_VOLT_V2
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 098
HV battery module 098 voltage GENESIS_HVBAT_CMU098_VOLT
- Request
22 01 05 - Service 22
DID 0105 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 280 to 287 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2017 to 2026.
HV battery module 098 voltage GENESIS_HVBAT_CMU098_VOLT_V2
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 099
HV battery module 099 voltage GENESIS_HVBAT_CMU099_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 100
HV battery module 100 voltage GENESIS_HVBAT_CMU100_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 101
HV battery module 101 voltage GENESIS_HVBAT_CMU101_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 102
HV battery module 102 voltage GENESIS_HVBAT_CMU102_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 103
HV battery module 103 voltage GENESIS_HVBAT_CMU103_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 104
HV battery module 104 voltage GENESIS_HVBAT_CMU104_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 105
HV battery module 105 voltage GENESIS_HVBAT_CMU105_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 106
HV battery module 106 voltage GENESIS_HVBAT_CMU106_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 107
HV battery module 107 voltage GENESIS_HVBAT_CMU107_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 108
HV battery module 108 voltage GENESIS_HVBAT_CMU108_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 109
HV battery module 109 voltage GENESIS_HVBAT_CMU109_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 110
HV battery module 110 voltage GENESIS_HVBAT_CMU110_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 111
HV battery module 111 voltage GENESIS_HVBAT_CMU111_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 144 to 151 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 112
HV battery module 112 voltage GENESIS_HVBAT_CMU112_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 152 to 159 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 113
HV battery module 113 voltage GENESIS_HVBAT_CMU113_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 160 to 167 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 114
HV battery module 114 voltage GENESIS_HVBAT_CMU114_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 115
HV battery module 115 voltage GENESIS_HVBAT_CMU115_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 116
HV battery module 116 voltage GENESIS_HVBAT_CMU116_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 117
HV battery module 117 voltage GENESIS_HVBAT_CMU117_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 118
HV battery module 118 voltage GENESIS_HVBAT_CMU118_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 200 to 207 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 119
HV battery module 119 voltage GENESIS_HVBAT_CMU119_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 208 to 215 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 120
HV battery module 120 voltage GENESIS_HVBAT_CMU120_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 216 to 223 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 121
HV battery module 121 voltage GENESIS_HVBAT_CMU121_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 224 to 231 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 122
HV battery module 122 voltage GENESIS_HVBAT_CMU122_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 232 to 239 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 123
HV battery module 123 voltage GENESIS_HVBAT_CMU123_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 240 to 247 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 124
HV battery module 124 voltage GENESIS_HVBAT_CMU124_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 125
HV battery module 125 voltage GENESIS_HVBAT_CMU125_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 256 to 263 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 126
HV battery module 126 voltage GENESIS_HVBAT_CMU126_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 264 to 271 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 127
HV battery module 127 voltage GENESIS_HVBAT_CMU127_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 272 to 279 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 128
HV battery module 128 voltage GENESIS_HVBAT_CMU128_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 280 to 287 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 129
HV battery module 129 voltage GENESIS_HVBAT_CMU129_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 130
HV battery module 130 voltage GENESIS_HVBAT_CMU130_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 131
HV battery module 131 voltage GENESIS_HVBAT_CMU131_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 132
HV battery module 132 voltage GENESIS_HVBAT_CMU132_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 133
HV battery module 133 voltage GENESIS_HVBAT_CMU133_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 134
HV battery module 134 voltage GENESIS_HVBAT_CMU134_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 135
HV battery module 135 voltage GENESIS_HVBAT_CMU135_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 136
HV battery module 136 voltage GENESIS_HVBAT_CMU136_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 137
HV battery module 137 voltage GENESIS_HVBAT_CMU137_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 138
HV battery module 138 voltage GENESIS_HVBAT_CMU138_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 139
HV battery module 139 voltage GENESIS_HVBAT_CMU139_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 140
HV battery module 140 voltage GENESIS_HVBAT_CMU140_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 141
HV battery module 141 voltage GENESIS_HVBAT_CMU141_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 142
HV battery module 142 voltage GENESIS_HVBAT_CMU142_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 143
HV battery module 143 voltage GENESIS_HVBAT_CMU143_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 144 to 151 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 144
HV battery module 144 voltage GENESIS_HVBAT_CMU144_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 152 to 159 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 145
HV battery module 145 voltage GENESIS_HVBAT_CMU145_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 160 to 167 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 146
HV battery module 146 voltage GENESIS_HVBAT_CMU146_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 147
HV battery module 147 voltage GENESIS_HVBAT_CMU147_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 148
HV battery module 148 voltage GENESIS_HVBAT_CMU148_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 149
HV battery module 149 voltage GENESIS_HVBAT_CMU149_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 150
HV battery module 150 voltage GENESIS_HVBAT_CMU150_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 200 to 207 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 151
HV battery module 151 voltage GENESIS_HVBAT_CMU151_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 208 to 215 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 152
HV battery module 152 voltage GENESIS_HVBAT_CMU152_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 216 to 223 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 153
HV battery module 153 voltage GENESIS_HVBAT_CMU153_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 224 to 231 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 154
HV battery module 154 voltage GENESIS_HVBAT_CMU154_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 232 to 239 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 155
HV battery module 155 voltage GENESIS_HVBAT_CMU155_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 240 to 247 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 156
HV battery module 156 voltage GENESIS_HVBAT_CMU156_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 157
HV battery module 157 voltage GENESIS_HVBAT_CMU157_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 256 to 263 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 158
HV battery module 158 voltage GENESIS_HVBAT_CMU158_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 264 to 271 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 159
HV battery module 159 voltage GENESIS_HVBAT_CMU159_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 272 to 279 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 160
HV battery module 160 voltage GENESIS_HVBAT_CMU160_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 280 to 287 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 161
HV battery module 161 voltage GENESIS_HVBAT_CMU161_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 162
HV battery module 162 voltage GENESIS_HVBAT_CMU162_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 163
HV battery module 163 voltage GENESIS_HVBAT_CMU163_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 164
HV battery module 164 voltage GENESIS_HVBAT_CMU164_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 165
HV battery module 165 voltage GENESIS_HVBAT_CMU165_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 166
HV battery module 166 voltage GENESIS_HVBAT_CMU166_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 167
HV battery module 167 voltage GENESIS_HVBAT_CMU167_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 168
HV battery module 168 voltage GENESIS_HVBAT_CMU168_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 169
HV battery module 169 voltage GENESIS_HVBAT_CMU169_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 170
HV battery module 170 voltage GENESIS_HVBAT_CMU170_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 171
HV battery module 171 voltage GENESIS_HVBAT_CMU171_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 172
HV battery module 172 voltage GENESIS_HVBAT_CMU172_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 173
HV battery module 173 voltage GENESIS_HVBAT_CMU173_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 174
HV battery module 174 voltage GENESIS_HVBAT_CMU174_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 175
HV battery module 175 voltage GENESIS_HVBAT_CMU175_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 144 to 151 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 176
HV battery module 176 voltage GENESIS_HVBAT_CMU176_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 152 to 159 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 177
HV battery module 177 voltage GENESIS_HVBAT_CMU177_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 160 to 167 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 178
HV battery module 178 voltage GENESIS_HVBAT_CMU178_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 179
HV battery module 179 voltage GENESIS_HVBAT_CMU179_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 180
HV battery module 180 voltage GENESIS_HVBAT_CMU180_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 181
HV battery module 181 voltage GENESIS_HVBAT_CMU181_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 182
HV battery module 182 voltage GENESIS_HVBAT_CMU182_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 200 to 207 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 183
HV battery module 183 voltage GENESIS_HVBAT_CMU183_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 208 to 215 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 184
HV battery module 184 voltage GENESIS_HVBAT_CMU184_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 216 to 223 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 185
HV battery module 185 voltage GENESIS_HVBAT_CMU185_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 224 to 231 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 186
HV battery module 186 voltage GENESIS_HVBAT_CMU186_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 232 to 239 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 187
HV battery module 187 voltage GENESIS_HVBAT_CMU187_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 240 to 247 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 188
HV battery module 188 voltage GENESIS_HVBAT_CMU188_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 189
HV battery module 189 voltage GENESIS_HVBAT_CMU189_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 256 to 263 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 190
HV battery module 190 voltage GENESIS_HVBAT_CMU190_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 264 to 271 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 191
HV battery module 191 voltage GENESIS_HVBAT_CMU191_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 272 to 279 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.
Battery › Modules › 192
HV battery module 192 voltage GENESIS_HVBAT_CMU192_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 280 to 287 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2017 to 2026.