4WD calculated clutch power GENESIS_AWD_CALC_CLU_POWER

  • Request22 01 A3
  • Service 22DID 01A3
  • Module740 → 748
  • Every250 ms
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
(val × 39.062 ÷ 10000)
Range
0 to 255 kWh
Unit
kWh

In testing for 2017 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

4WD calculated clutch power GENESIS_AWD_CALC_CLU_POWER

  • Request22 01 A3
  • Service 22DID 01A3
  • Module740 → 748
  • Every250 ms
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
(val × 39.062 ÷ 10000)
Range
0 to 255 kWh
Unit
kWh

In testing for 2017 to 2026.

4WD calculated engine power GENESIS_AWD_CALC_ENG_POWER

  • Request22 01 A3
  • Service 22DID 01A3
  • Module740 → 748
  • Every250 ms
  • Testing

Bits 72 to 87 of the reply, 16 bits.

Formula
(val × 9.766 ÷ 10000)
Range
0 to 64 kWh
Unit
kWh

In testing for 2017 to 2026.

4WD calculated, commanded torque GENESIS_AWD_CALC_CMD_TQ

  • Request22 01 A1
  • Service 22DID 01A1
  • Module740 → 748
  • Every250 ms
  • Testing

Bits 40 to 55 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 8)
Range
-4096 to 4095.875 N·m
Unit
N·m

In testing for 2017 to 2026.

4WD clutch duty GENESIS_AWD_CLU_DUTY

  • Request22 01 A1
  • Service 22DID 01A1
  • Module740 → 748
  • Every250 ms
  • Testing

Bits 72 to 87 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 100 %
Unit
%

In testing for 2017 to 2026.

4WD clutch pressure GENESIS_AWD_CLU_P

  • Request22 01 A1
  • Service 22DID 01A1
  • Module740 → 748
  • Every250 ms
  • Testing

Bits 216 to 231 of the reply, 16 bits. The value is signed.

Formula
(val × 0.001953)
Range
-63.99 to 63.99 bar
Unit
bar

In testing for 2017 to 2026.

4WD clutch stress GENESIS_AWD_CLU_STRESS

  • Request22 01 A1
  • Service 22DID 01A1
  • Module740 → 748
  • Every250 ms
  • Testing

Bits 104 to 119 of the reply, 16 bits. The value is signed.

Formula
(val × 0.001953)
Range
-63.99 to 63.99 %
Unit
%

In testing for 2017 to 2026.

4WD clutch torque GENESIS_AWD_CLU_TQ

  • Request22 01 A1
  • Service 22DID 01A1
  • Module740 → 748
  • Every250 ms
  • Testing

Bits 200 to 215 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16)
Range
-2048 to 2047.9375 N·m
Unit
N·m

In testing for 2017 to 2026.

4WD clutch, actual pressure GENESIS_AWD_CLU_ACT_P

  • Request22 01 A1
  • Service 22DID 01A1
  • Module740 → 748
  • Every250 ms
  • Testing

Bits 144 to 159 of the reply, 16 bits. The value is signed.

Formula
(val × 19.53 ÷ 10000)
Range
-63.99 to 63.99 bar
Unit
bar

In testing for 2017 to 2026.

4WD clutch, actual torque GENESIS_AWD_CLU_ACT_TQ

  • Request22 01 A1
  • Service 22DID 01A1
  • Module740 → 748
  • Every250 ms
  • Testing

Bits 128 to 143 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 8)
Range
-4096 to 4095.875 N·m
Unit
N·m

In testing for 2017 to 2026.

4WD front axle ratio GENESIS_AWD_FRONT_AXLE_RAT

  • Request22 01 A3
  • Service 22DID 01A3
  • Module740 → 748
  • Every250 ms
  • Testing

Bits 56 to 71 of the reply, 16 bits. The value is signed.

Formula
(val × 2 ÷ 65535)
Range
-1 to 0.999
Unit
Number

In testing for 2017 to 2026.

4WD max clutch stress GENESIS_AWD_MAX_CLU_STRESS

  • Request22 01 A1
  • Service 22DID 01A1
  • Module740 → 748
  • Every250 ms
  • Testing

Bits 88 to 103 of the reply, 16 bits.

Formula
(val × 19.531 ÷ 10000)
Range
0 to 100 %
Unit
%

In testing for 2017 to 2026.

4WD pump current GENESIS_AWD_PMP_CURRENT

  • Request22 01 A1
  • Service 22DID 01A1
  • Module740 → 748
  • Every250 ms
  • Testing

Bits 112 to 127 of the reply, 16 bits. The value is signed.

Formula
(val × 78.125 ÷ 10000)
Range
-256 to 255 A
Unit
A

In testing for 2017 to 2026.

4WD pump PWM duty GENESIS_AWD_PMP_PWM_DUTY

  • Request22 01 A1
  • Service 22DID 01A1
  • Module740 → 748
  • Every250 ms
  • Testing

Bits 56 to 71 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 100 %
Unit
%

In testing for 2017 to 2026.

Adaptation value for lower stop of wastegate actuator GENESIS_ADPT_LO_STOP

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 384 to 399 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val × 1.53 ÷ 10000)
Range
-5.01 to 5.01 V
Unit
V

In testing for 2017 to 2026.

Air conditioning pressure GENESIS_AC_P

  • Request22 E0 14
  • Service 22DID E014
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
(val × 3520 ÷ 255)
Range
0 to 3520 kPa
Unit
kPa

In testing for 2017 to 2026.

Air conditioning pressure GENESIS_CRUZ_AC_P

  • Request22 E0 14
  • Service 22DID E014
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
(val × 13.79)
Range
0 to 3516.45 kPa
Unit
kPa

In testing for 2017 to 2026.

Air conditioning relay GENESIS_AC_RELAY

  • Request22 ED 01
  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 101 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2017 to 2026.

Automatic transmission fluid temperature GENESIS_ATF_T_7E1

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 01 A0
  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2017 to 2026.

AUX amps LDC GENESIS_AUX_AMPS_LDC

  • Request21 02
  • Service 21PID 02
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 A
Unit
A

In testing for 2017 to 2026.

Barometric pressure GENESIS_BAROMETRIC_PRESSURE

  • Request21 13
  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 312 to 319 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127.5 kPa
Unit
kPa

In testing for 2017 to 2026.

Battery management ignition GENESIS_BAT_MANAGEMENT_IGN

  • Request21 01
  • Service 21PID 01
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bit 405 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2017 to 2026.

Battery management main relay GENESIS_BAT_MANAGEMENT_MAIN

  • Request21 01
  • Service 21PID 01
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bit 79 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2017 to 2026.

Boost pressure GENESIS_BOOST_P

  • Request22 ED 01
  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 200 to 207 of the reply, 8 bits.

Formula
(val × 1372549 ÷ 100000)
Range
0 to 3499.9999
Unit
Raw value

In testing for 2017 to 2026.

Boost pressure GENESIS_BOOST_P_V2

  • Request22 E0 F2
  • Service 22DID E0F2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 496 to 511 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2017 to 2026.

Boost pressure upstream GENESIS_BOOST_P_UP

  • Request22 E0 03
  • Service 22DID E003
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 280 to 295 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 39 ÷ 500)
Range
0 to 5111
Unit
Raw value

In testing for 2017 to 2026.

Boost pressure upstream, desired GENESIS_BOOST_P_UP_DES

  • Request22 E0 03
  • Service 22DID E003
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 312 to 327 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 39 ÷ 500)
Range
0 to 5111
Unit
Raw value

In testing for 2017 to 2026.

Boost regulator duty GENESIS_BOOST_REGULATOR_DUTY

  • Request22 ED 01
  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 208 to 215 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 2017 to 2026.

Calculated oil temperature GENESIS_CALC_OIL_T

  • Request22 E0 11
  • Service 22DID E011
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2017 to 2026.

Calculated oil temperature GENESIS_CRUZ_CALC_OIL_T

  • Request22 E0 11
  • Service 22DID E011
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2017 to 2026.

Camshaft exhaust position, actual GENESIS_CAM_EXH_POS_ACT

  • Request21 20
  • Service 21PID 20
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
(val × -3 ÷ 8 − 40)
Range
-135 to -40 °
Unit
°

In testing for 2017 to 2026.

Camshaft exhaust position, commanded GENESIS_CAM_EXH_POS_CMD

  • Request21 20
  • Service 21PID 20
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
(val × -3 ÷ 8 − 40)
Range
-135 to -40 °
Unit
°

In testing for 2017 to 2026.

Camshaft intake position, actual GENESIS_CAM_INT_POS_ACT

  • Request21 20
  • Service 21PID 20
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
(val × 3 ÷ 8 + 60)
Range
0 to 155 °
Unit
°

In testing for 2017 to 2026.

Camshaft intake position, commanded GENESIS_CAM_INT_POS_CMD

  • Request21 20
  • Service 21PID 20
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
(val × 3 ÷ 8 + 60)
Range
0 to 155 °
Unit
°

In testing for 2017 to 2026.

Catalyst damaging misfires total all cylinders GENESIS_CATALYST_DAMAGING_MISFIRES_TOTAL_ALL_CYLINDERS

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 448 to 463 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Catalyst damaging misfires total all cylinders GENESIS_CATDMG_MIS_TOT_ALL

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 400 to 415 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Catalyst damaging misfires total, cylinder 1 GENESIS_CATALYST_DAMAGING_MISFIRES_TOTAL_C1

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 304 to 319 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Catalyst damaging misfires total, cylinder 1 GENESIS_CATDMG_MIS_TOT_1

  • Request22 E0 1D
  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Catalyst damaging misfires total, cylinder 1 GENESIS_CATDMG_MIS_TOT_1_7E0

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Catalyst damaging misfires total, cylinder 1 GENESIS_CATDMG_MIS_TOT_1_V2

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Catalyst damaging misfires total, cylinder 2 GENESIS_CATALYST_DAMAGING_MISFIRES_TOTAL_C2

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 320 to 335 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Catalyst damaging misfires total, cylinder 2 GENESIS_CATDMG_MIS_TOT_2

  • Request22 E0 1D
  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Catalyst damaging misfires total, cylinder 2 GENESIS_CATDMG_MIS_TOT_2_7E0

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 272 to 287 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Catalyst damaging misfires total, cylinder 2 GENESIS_CATDMG_MIS_TOT_2_V2

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Catalyst damaging misfires total, cylinder 3 GENESIS_CATALYST_DAMAGING_MISFIRES_TOTAL_C3

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 336 to 351 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Catalyst damaging misfires total, cylinder 3 GENESIS_CATDMG_MIS_TOT_3

  • Request22 E0 1D
  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Catalyst damaging misfires total, cylinder 3 GENESIS_CATDMG_MIS_TOT_3_7E0

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 288 to 303 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Catalyst damaging misfires total, cylinder 3 GENESIS_CATDMG_MIS_TOT_3_V2

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Catalyst damaging misfires total, cylinder 4 GENESIS_CATALYST_DAMAGING_MISFIRES_TOTAL_C4

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 352 to 367 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Catalyst damaging misfires total, cylinder 4 GENESIS_CATDMG_MIS_TOT_4

  • Request22 E0 1D
  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Catalyst damaging misfires total, cylinder 4 GENESIS_CATDMG_MIS_TOT_4_7E0

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 304 to 319 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Catalyst damaging misfires total, cylinder 4 GENESIS_CATDMG_MIS_TOT_4_V2

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Catalyst damaging misfires total, cylinder 5 GENESIS_CATDMG_MIS_TOT_5

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 320 to 335 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Catalyst damaging misfires total, cylinder 5 GENESIS_CATDMG_MIS_TOT_5_V2

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Catalyst damaging misfires total, cylinder 6 GENESIS_CATDMG_MIS_TOT_6

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 336 to 351 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Catalyst damaging misfires total, cylinder 6 GENESIS_CATDMG_MIS_TOT_6_V2

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 240 to 255 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Clutch solenoid duty GENESIS_CLUTCH_SOLENOID_DUTY

  • Request21 C0
  • Service 21PID C0
  • Module7E5
  • Every250 ms
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2017 to 2026.

Commanded evaporative purge GENESIS_COMMANDED_EVAPORATIVE_PURGE

  • Request21 02
  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
(val × 0.390625)
Range
0 to 99.6 %
Unit
%

In testing for 2017 to 2026.

Commanded throttle actuator GENESIS_COMMANDED_THROTTLE_ACTUATOR

  • Request21 14
  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val × 0.390625)
Range
0 to 99.6 %
Unit
%

In testing for 2017 to 2026.

Commanded torque GENESIS_COMMANDED_TORQUE

  • Request21 C0
  • Service 21PID C0
  • Module7E5
  • Every250 ms
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
(val × 10)
Range
0 to 2550 N·m
Unit
N·m

In testing for 2017 to 2026.

Coolant GENESIS_COOLANT_FAN

  • Request21 14
  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2017 to 2026.

Coolant fan PWM GENESIS_CLT_FAN_PWM

  • Request22 E0 14
  • Service 22DID E014
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

In testing for 2017 to 2026.

Coolant fan PWM GENESIS_CRUZ_CLT_FAN_PWM

  • Request22 E0 14
  • Service 22DID E014
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 88 to 103 of the reply, 16 bits.

Formula
(val × 15.21 ÷ 10000)
Range
0 to 99.67 %
Unit
%

In testing for 2017 to 2026.

Coolant temperature GENESIS_HVAC_COOLANT_T

  • Request22 01 02
  • Service 22DID 0102
  • Module7B3 → 7BB
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

In testing for 2017 to 2026.

Coverage driven length GENESIS_CRUZ_COVERAGE_DRIVEN

  • Request22 E0 09
  • Service 22DID E009
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 392 to 423 of the reply, 32 bits. The bytes are in little-endian order.

Formula
(val ÷ 1000)
Range
0 to 4294967 km
Unit
km

In testing for 2017 to 2026.

Crankshaft torque GENESIS_CRANK_TQ

  • Request22 ED 05
  • Service 22DID ED05
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 240 to 247 of the reply, 8 bits.

Formula
(val × 600 ÷ 255)
Range
0 to 600 N·m
Unit
N·m

In testing for 2017 to 2026.

Cylinder 1 injection time, 1st pulse GENESIS_CYL_1_INJ_TIME_1ST

  • Request21 23
  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 264 to 279 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Cylinder 1 injection time, 2nd pulse GENESIS_CYL_1_INJ_TIME_2ND

  • Request21 23
  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 200 to 215 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Cylinder 2 injection time, 1st pulse GENESIS_CYL_2_INJ_TIME_1ST

  • Request21 23
  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 280 to 295 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Cylinder 2 injection time, 2nd pulse GENESIS_CYL_2_INJ_TIME_2ND

  • Request21 23
  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 216 to 231 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Cylinder 3 injection time, 1st pulse GENESIS_CYL_3_INJ_TIME_1ST

  • Request21 23
  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 296 to 311 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Cylinder 3 injection time, 2nd pulse GENESIS_CYL_3_INJ_TIME_2ND

  • Request21 23
  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 232 to 247 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Cylinder 4 injection time, 1st pulse GENESIS_CYL_4_INJ_TIME_1ST

  • Request21 23
  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 312 to 327 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Cylinder 4 injection time, 2nd pulse GENESIS_CYL_4_INJ_TIME_2ND

  • Request21 23
  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 248 to 263 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Cylinder 5 injection time 1st pulse GENESIS_CYL_5_INJ_TIME_1ST

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 392 to 407 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 250)
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Cylinder 5 injection time 2nd pulse GENESIS_CYL_5_INJ_TIME_2ND

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 360 to 375 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 250)
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Cylinder 6 injection time 1st pulse GENESIS_CYL_6_INJ_TIME_1ST

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 408 to 423 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 250)
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Cylinder 6 injection time 2nd pulse GENESIS_CYL_6_INJ_TIME_2ND

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 376 to 391 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 250)
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Diesel particulate filter differential pressure GENESIS_DPF_DIFF_P

  • Request22 E0 F1
  • Service 22DID E0F1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
(val × 4.3137 − 100)
Range
-100 to 999.9935
Unit
Raw value

In testing for 2017 to 2026.

Diesel particulate filter differential pressure GENESIS_DPF_DIFF_P_7E0

  • Request22 ED 03
  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 288 to 295 of the reply, 8 bits.

Formula
(val × 431.373 ÷ 100)
Range
0 to 1100
Unit
Raw value

In testing for 2017 to 2026.

Diesel particulate filter differential pressure GENESIS_DPF_DIFFERENTIAL_PRESSURE

  • Request21 1B
  • Service 21PID 1B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2)
Range
0 to 32767.5
Unit
Raw value

In testing for 2017 to 2026.

Diesel particulate filter load, from model GENESIS_DPF_LOAD_MODEL

  • Request22 ED 03
  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 296 to 303 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2017 to 2026.

Diesel particulate filter regen demand counter GENESIS_DPF_REGEN_DEMAND_CNT

  • Request22 ED 03
  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 432 to 439 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2026.

Diesel particulate filter regen success state GENESIS_DPF_REGEN_SUCCESS_ST

  • Request22 ED 03
  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bit 407 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2017 to 2026.

Diesel particulate filter regen, completed state GENESIS_DPF_REGEN_COMPLETED

  • Request22 ED 06
  • Service 22DID ED06
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 200 to 207 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2026.

Diesel particulate filter regeneration count GENESIS_DPF_REGEN_CNT

  • Request22 ED 03
  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 440 to 447 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2026.

Diesel particulate filter regeneration state GENESIS_DPF_REGEN_ST

  • Request22 ED 03
  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bit 431 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2017 to 2026.

Diesel particulate filter regeneration state GENESIS_DPF_REGENERATION_STATE

  • Request21 06
  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 207 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2017 to 2026.

Diesel particulate filter soot GENESIS_DPF_SOOT

  • Request22 ED 1D
  • Service 22DID ED1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 256 ÷ 65535)
Range
0 to 256
Unit
Raw value

In testing for 2017 to 2026.

Diesel particulate filter soot mass GENESIS_DPF_SOOT_MASS

  • Request22 ED 94
  • Service 22DID ED94
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
(val × 99 ÷ 255)
Range
0 to 99 g
Unit
g

In testing for 2017 to 2026.

Diesel particulate filter successful regeneration count GENESIS_DPF_SUCCESSFUL_REGEN

  • Request22 E0 F2
  • Service 22DID E0F2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 432 to 447 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Diesel particulate filter total sulfur mass GENESIS_DPF_TOT_SULFUR_MASS

  • Request22 ED 29
  • Service 22DID ED29
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.15259)
Range
0 to 9999
Unit
Raw value

In testing for 2017 to 2026.

Direct injection time 1 GENESIS_DI_TIME_1

  • Request21 0B
  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 100 ÷ 13107)
Range
0 to 500 ms
Unit
ms

In testing for 2017 to 2026.

Direct injection time 1st pulse, cylinder 1 GENESIS_DI_TIME_1ST_CYL_1

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 264 to 279 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Direct injection time 1st pulse, cylinder 2 GENESIS_DI_TIME_1ST_CYL_2

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 280 to 295 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Direct injection time 1st pulse, cylinder 3 GENESIS_DI_TIME_1ST_CYL_3

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 296 to 311 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Direct injection time 1st pulse, cylinder 4 GENESIS_DI_TIME_1ST_CYL_4

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 312 to 327 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Direct injection time 1st pulse, cylinder 5 GENESIS_CYL5_INJ_TIME_1ST

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 392 to 407 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Direct injection time 1st pulse, cylinder 6 GENESIS_CYL6_INJ_TIME_1ST

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 408 to 423 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Direct injection time 2 GENESIS_DI_TIME_2

  • Request21 0B
  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 100 ÷ 13107)
Range
0 to 500 ms
Unit
ms

In testing for 2017 to 2026.

Direct injection time 2nd pulse, cylinder 1 GENESIS_DI_TIME_2ND_CYL_1

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 200 to 215 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Direct injection time 2nd pulse, cylinder 2 GENESIS_DI_TIME_2ND_CYL_2

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 216 to 231 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Direct injection time 2nd pulse, cylinder 3 GENESIS_DI_TIME_2ND_CYL_3

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 232 to 247 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Direct injection time 2nd pulse, cylinder 4 GENESIS_DI_TIME_2ND_CYL_4

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 248 to 263 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Direct injection time 2nd pulse, cylinder 5 GENESIS_CYL5_INJ_TIME_2ND

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 360 to 375 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Direct injection time 2nd pulse, cylinder 6 GENESIS_CYL6_INJ_TIME_2ND

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 376 to 391 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Direct injection time 3 GENESIS_DI_TIME_3

  • Request21 0B
  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 100 ÷ 13107)
Range
0 to 500 ms
Unit
ms

In testing for 2017 to 2026.

Direct injection time 4 GENESIS_DI_TIME_4

  • Request21 0B
  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 100 ÷ 13107)
Range
0 to 500 ms
Unit
ms

In testing for 2017 to 2026.

Direct injection time 5 GENESIS_DI_TIME_5

  • Request21 0B
  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 100 ÷ 13107)
Range
0 to 500 ms
Unit
ms

In testing for 2017 to 2026.

Direct injection time 6 GENESIS_DI_TIME_6

  • Request21 0B
  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 127 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 100 ÷ 13107)
Range
0 to 500 ms
Unit
ms

In testing for 2017 to 2026.

Disconnector actuator motor current GENESIS_DISCONNECTOR_ACTUATOR_MOTOR_CURRENT

  • Request22 E0 05
  • Service 22DID E005
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits. The value is signed.

Formula
(val × 2)
Range
-256 to 254 A
Unit
A

In testing for 2017 to 2026.

Disconnector disengage last time GENESIS_DISCONNECTOR_DISENGAGE_LAST_TIME

  • Request22 E0 05
  • Service 22DID E005
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 255 ms
Unit
ms

In testing for 2017 to 2026.

Disconnector end point GENESIS_DISCONNECTOR_END_POINT

  • Request22 E0 05
  • Service 22DID E005
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 128)
Range
0 to 511 mm
Unit
mm

In testing for 2017 to 2026.

Disconnector inverter PWM duty GENESIS_DISCONNECTOR_INVERTER_PWM_DUTY

  • Request22 E0 05
  • Service 22DID E005
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 104 to 119 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val × 78.125 ÷ 10000)
Range
0 to 100 %
Unit
%

In testing for 2017 to 2026.

Disconnector meet point GENESIS_DISCONNECTOR_MEET_POINT

  • Request22 E0 05
  • Service 22DID E005
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 128)
Range
0 to 511 mm
Unit
mm

In testing for 2017 to 2026.

Disconnector stroke position GENESIS_DISCONNECTOR_STROKE_POSITION

  • Request22 E0 05
  • Service 22DID E005
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 128)
Range
0 to 511 mm
Unit
mm

In testing for 2017 to 2026.

Disconnector zero count offset GENESIS_DISCONNECTOR_ZERO_COUNT_OFFSET

  • Request22 E0 05
  • Service 22DID E005
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 120 to 135 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767
Unit
Number

In testing for 2017 to 2026.

Drive motor speed GENESIS_RPM_7E4

  • Request22 01 01
  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 424 to 439 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2017 to 2026.

Drive motor speed GENESIS_RPM_V2

  • Request22 01 01
  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 424 to 439 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2017 to 2026.

Drive motor speed 2 GENESIS_RPM_2

  • Request22 01 01
  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 440 to 455 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2017 to 2026.

Drive motor temperature GENESIS_DRIVE_MOTOR_T

  • Request22 E0 02
  • Service 22DID E002
  • Module7E3 → 7EB
  • Every5 s
  • Testing

Bits 96 to 111 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val ÷ 100)
Range
-327 to 327 °C
Unit
°C

In testing for 2017 to 2026.

Drive motor torque reference GENESIS_DRIVE_MOTOR_TQ

  • Request22 E0 02
  • Service 22DID E002
  • Module7E3 → 7EB
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2017 to 2026.

Drive motor torque, actual GENESIS_DRIVE_MOTOR_TQ_ACT

  • Request22 E0 02
  • Service 22DID E002
  • Module7E3 → 7EB
  • Every5 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2017 to 2026.

Dual-clutch transmission clutch 1, pressure sensor a GENESIS_DUAL_CLU_TRANS_CLU_1_P

  • Request22 01 A5
  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
(val × 19.53 ÷ 10000)
Range
0 to 127 bar
Unit
bar

In testing for 2017 to 2026.

Dual-clutch transmission clutch 2, pressure sensor b GENESIS_DUAL_CLU_TRANS_CLU_2_P_B

  • Request22 01 A5
  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
(val × 19.53 ÷ 10000)
Range
0 to 127 bar
Unit
bar

In testing for 2017 to 2026.

Dual-clutch transmission fluid temperature 1 GENESIS_DUAL_CLU_ATF_T_1

  • Request22 01 A5
  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2017 to 2026.

Dual-clutch transmission fluid temperature 2 GENESIS_DUAL_CLU_ATF_T_2

  • Request22 01 A5
  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2017 to 2026.

Dual-clutch transmission line pressure, sensor c GENESIS_DUAL_CLU_TRANS_LINE_P_C

  • Request22 01 A5
  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
(val × 19.53 ÷ 10000)
Range
0 to 127 bar
Unit
bar

In testing for 2017 to 2026.

Emission relevant misfires total all cylinders GENESIS_EMIS_MIS_TOT_ALL

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 384 to 399 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Emission relevant misfires total all cylinders GENESIS_EMISSION_RELEVANT_MISFIRES_TOTAL_ALL_CYLINDERS

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 432 to 447 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Emission relevant misfires total, cylinder 1 GENESIS_EMIS_MIS_TOT_1

  • Request22 E0 1D
  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Emission relevant misfires total, cylinder 1 GENESIS_EMIS_MIS_TOT_1_7E0

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 128 to 143 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Emission relevant misfires total, cylinder 1 GENESIS_EMIS_MIS_TOT_1_V2

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Emission relevant misfires total, cylinder 1 GENESIS_EMISSION_RELEVANT_MISFIRES_TOTAL_C1

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Emission relevant misfires total, cylinder 2 GENESIS_EMIS_MIS_TOT_2

  • Request22 E0 1D
  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Emission relevant misfires total, cylinder 2 GENESIS_EMIS_MIS_TOT_2_7E0

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 144 to 159 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Emission relevant misfires total, cylinder 2 GENESIS_EMIS_MIS_TOT_2_V2

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Emission relevant misfires total, cylinder 2 GENESIS_EMISSION_RELEVANT_MISFIRES_TOTAL_C2

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Emission relevant misfires total, cylinder 3 GENESIS_EMIS_MIS_TOT_3

  • Request22 E0 1D
  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Emission relevant misfires total, cylinder 3 GENESIS_EMIS_MIS_TOT_3_7E0

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Emission relevant misfires total, cylinder 3 GENESIS_EMIS_MIS_TOT_3_V2

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Emission relevant misfires total, cylinder 3 GENESIS_EMISSION_RELEVANT_MISFIRES_TOTAL_C3

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Emission relevant misfires total, cylinder 4 GENESIS_EMIS_MIS_TOT_4

  • Request22 E0 1D
  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Emission relevant misfires total, cylinder 4 GENESIS_EMIS_MIS_TOT_4_7E0

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Emission relevant misfires total, cylinder 4 GENESIS_EMIS_MIS_TOT_4_V2

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Emission relevant misfires total, cylinder 4 GENESIS_EMISSION_RELEVANT_MISFIRES_TOTAL_C4

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Emission relevant misfires total, cylinder 5 GENESIS_EMIS_MIS_TOT_5

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Emission relevant misfires total, cylinder 5 GENESIS_EMIS_MIS_TOT_5_V2

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Emission relevant misfires total, cylinder 6 GENESIS_EMIS_MIS_TOT_6

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Emission relevant misfires total, cylinder 6 GENESIS_EMIS_MIS_TOT_6_V2

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 127 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Engine coolant temperature GENESIS_ENGINE_COOLANT_T

Pelican can show this parameter as the engine coolant temperature.

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 200 to 207 of the reply, 8 bits.

Formula
(val × 0.75 − 48)
Range
-48 to 143.25 °C
Unit
°C

In testing for 2017 to 2026.

Engine oil temperature GENESIS_ENGINE_OIL_T

Pelican can show this parameter as the engine oil temperature.

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 272 to 279 of the reply, 8 bits.

Formula
(val × 0.75 − 48)
Range
-48 to 143.25 °C
Unit
°C

In testing for 2017 to 2026.

Engine oil temperature GENESIS_EOT

Pelican can show this parameter as the engine oil temperature.

  • Request22 E0 01
  • Service 22DID E001
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 272 to 279 of the reply, 8 bits.

Formula
(val ÷ 1.3333 − 48)
Range
0 to 143 °C
Unit
°C

In testing for 2017 to 2026.

Engine oil temperature GENESIS_EOT_26

Pelican can show this parameter as the engine oil temperature.

  • Request22 E0 01
  • Service 22DID E001
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 272 to 279 of the reply, 8 bits.

Formula
(val × 3 ÷ 4 − 48)
Range
-48 to 143 °C
Unit
°C

In testing for 2017 to 2026.

Engine oil temperature GENESIS_EOT_7E0

  • Request22 E0 01
  • Service 22DID E001
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 272 to 279 of the reply, 8 bits.

Formula
(val × 3 ÷ 4 − 48)
Range
-48 to 143 °C
Unit
°C

In testing for 2017 to 2026.

Engine oil temperature GENESIS_EOT_7E0_7E0

  • Request22 ED 07
  • Service 22DID ED07
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 152 to 159 of the reply, 8 bits.

Formula
(val × 0.7843 − 50)
Range
-50 to 149.9965 °C
Unit
°C

In testing for 2017 to 2026.

Engine oil temperature GENESIS_EOT_7E0_V2

Pelican can show this parameter as the engine oil temperature.

  • Request22 ED 07
  • Service 22DID ED07
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 152 to 159 of the reply, 8 bits.

Formula
(val × 0.7843 − 50)
Range
-50 to 149.9965 °C
Unit
°C

In testing for 2017 to 2026.

Engine oil temperature GENESIS_EOT_V2

Pelican can show this parameter as the engine oil temperature.

  • Request22 ED 02
  • Service 22DID ED02
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
(val − 4)
Range
-4 to 251 °C
Unit
°C

In testing for 2017 to 2026.

Engine Oil Temperature GENESIS_OIL_TEMP

Pelican can show this parameter as the engine oil temperature.

  • Request22 E0 01
  • Service 22DID E001
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 272 to 279 of the reply, 8 bits.

Formula
(val ÷ 1.3333 − 48)
Range
0 to 143.254781 °C
Unit
°C

In testing for 2017 to 2026.

Engine RPM GENESIS_ENGINE_RPM_TCM

Pelican can show this parameter as the engine speed.

  • Request21 A0
  • Service 21PID A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2017 to 2026.

Engine RPM GENESIS_RPM_7E5

  • Request21 C0
  • Service 21PID C0
  • Module7E5
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2017 to 2026.

Engine RPM GENESIS_RPM_V3

Pelican can show this parameter as the engine speed.

  • Request21 C0
  • Service 21PID C0
  • Module7E5
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2017 to 2026.

Engine run time, total GENESIS_ENG_RUN_TIME_TOT

  • Request21 0E
  • Service 21PID 0E
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 6)
Range
0 to 393209.9999 min
Unit
min

In testing for 2017 to 2026.

Engine, actual torque GENESIS_ENG_ACT_TQ

  • Request22 ED 01
  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 240 to 247 of the reply, 8 bits.

Formula
(val × 2.3529)
Range
0 to 599.9895 N·m
Unit
N·m

In testing for 2017 to 2026.

Exhaust cam oil control valve duty GENESIS_OIL_CTRL_VLV_IMPULSE_WIDTH

  • Request21 20
  • Service 21PID 20
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 2017 to 2026.

Exhaust camshaft position GENESIS_EXH_CAM_POS

  • Request22 E0 20
  • Service 22DID E020
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 88 to 103 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val ÷ 128)
Range
-256 to 255 °
Unit
°

In testing for 2017 to 2026.

Exhaust gas flow in the particulate filter GENESIS_EXH_GAS_FLOW_PF

  • Request22 ED 03
  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 256 to 263 of the reply, 8 bits.

Formula
(val × 392157 ÷ 50)
Range
0 to 2000000.7 L
Unit
L

In testing for 2017 to 2026.

Exhaust gas temperature GENESIS_EXH_GAS_T

  • Request21 07
  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 632 to 639 of the reply, 8 bits.

Formula
(val × 5 − 50)
Range
-50 to 1225 °C
Unit
°C

In testing for 2017 to 2026.

Exhaust gas temperature GENESIS_EXHAUST_GAS_T

  • Request21 03
  • Service 21PID 03
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 368 to 375 of the reply, 8 bits.

Formula
(val × 4.709803922 + 99)
Range
99 to 1300 °C
Unit
°C

In testing for 2017 to 2026.

Exhaust gas temperature at catalyst GENESIS_EXH_GAS_T_CAT

  • Request22 ED 03
  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 272 to 279 of the reply, 8 bits.

Formula
(val × 471 ÷ 100 + 99)
Range
0 to 1300.05 °C
Unit
°C

In testing for 2017 to 2026.

Exhaust gas temperature before gasoline particulate filter sensor 1 GENESIS_CRUZ_EXH_GAS_T_BEFORE_GPF_1

  • Request22 E0 09
  • Service 22DID E009
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 288 to 303 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 12 ÷ 125)
Range
0 to 6291 °C
Unit
°C

In testing for 2017 to 2026.

Exhaust gas temperature before gasoline particulate filter sensor 2 GENESIS_CRUZ_EXH_GAS_T_BEFORE_GPF_2

  • Request22 E0 09
  • Service 22DID E009
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 304 to 319 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 12 ÷ 125)
Range
0 to 6291 °C
Unit
°C

In testing for 2017 to 2026.

Exhaust gas volume flow GENESIS_EXH_GAS_VOLUME_FLOW

  • Request22 E0 F1
  • Service 22DID E0F1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 240 to 247 of the reply, 8 bits.

Formula
(val × 78449 ÷ 10000)
Range
0 to 2000
Unit
Raw value

In testing for 2017 to 2026.

Exhaust temperature 1, upstream of oxidation catalyst GENESIS_EXH_T_1_UP_OXICAT

  • Request22 ED 03
  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 296 to 303 of the reply, 8 bits.

Formula
(val × 4.7098 + 99)
Range
0 to 1299.999 °C
Unit
°C

In testing for 2017 to 2026.

Exhaust temperature 2, upstream of DPF GENESIS_EXH_T_2_UP_DPF

  • Request22 ED 03
  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
(val × 4.7098 + 99)
Range
0 to 1299.999 °C
Unit
°C

In testing for 2017 to 2026.

Gasoline direct injection time bank a, 1 GENESIS_GDI_IT_A1

  • Request22 E0 05
  • Service 22DID E005
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
0 to 6553.5 ms
Unit
ms

In testing for 2017 to 2026.

Gasoline direct injection time bank a, 2 GENESIS_GDI_IT_A2

  • Request22 E0 05
  • Service 22DID E005
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 240 to 255 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
0 to 6553.5 ms
Unit
ms

In testing for 2017 to 2026.

Gasoline direct injection time bank a, 3 GENESIS_GDI_IT_A3

  • Request22 E0 05
  • Service 22DID E005
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
0 to 6553.5 ms
Unit
ms

In testing for 2017 to 2026.

Gasoline direct injection time bank a, 4 GENESIS_GDI_IT_A4

  • Request22 E0 05
  • Service 22DID E005
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 272 to 287 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
0 to 6553.5 ms
Unit
ms

In testing for 2017 to 2026.

Gasoline direct injection time bank b, 1 GENESIS_GDI_IT_B1

  • Request22 E0 05
  • Service 22DID E005
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 352 to 367 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
0 to 6553.5 ms
Unit
ms

In testing for 2017 to 2026.

Gasoline direct injection time bank b, 2 GENESIS_GDI_IT_B2

  • Request22 E0 05
  • Service 22DID E005
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 368 to 383 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
0 to 6553.5 ms
Unit
ms

In testing for 2017 to 2026.

Gasoline direct injection time bank b, 3 GENESIS_GDI_IT_B3

  • Request22 E0 05
  • Service 22DID E005
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 384 to 399 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
0 to 6553.5 ms
Unit
ms

In testing for 2017 to 2026.

Gasoline direct injection time bank b, 4 GENESIS_GDI_IT_B4

  • Request22 E0 05
  • Service 22DID E005
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 400 to 415 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
0 to 6553.5 ms
Unit
ms

In testing for 2017 to 2026.

Glow relay duty GENESIS_GLOW_RELAY_DUTY

  • Request22 ED 01
  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
(val × 2451 ÷ 6250)
Range
0 to 100 %
Unit
%

In testing for 2017 to 2026.

Heat GENESIS_HEAT

  • Request21 C0
  • Service 21PID C0
  • Module7E5
  • Every250 ms
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 2017 to 2026.

Heat sink temperature GENESIS_HEAT_SINK_T

  • Request22 E0 01
  • Service 22DID E001
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 448 to 463 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val ÷ 100)
Range
-327.68 to 327.67 °C
Unit
°C

In testing for 2017 to 2026.

Heat sink temperature GENESIS_HEAT_SINK_T_7E3

  • Request22 E0 02
  • Service 22DID E002
  • Module7E3 → 7EB
  • Every5 s
  • Testing

Bits 344 to 359 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
-3276 to 3276 °C
Unit
°C

In testing for 2017 to 2026.

Hv_charging GENESIS_HV_CHG

  • Request21 01
  • Service 21PID 01
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bit 72 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2017 to 2026.

Idle control mode GENESIS_IDLE_CONTROL_MODE

  • Request21 00
  • Service 21PID 00
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2026.

Ignition retard due to knock control 1 GENESIS_IGN_RETARD_KNOCK_1

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
(val × 0.75 − 191.25)
Range
-191.25 to 0 °
Unit
°

In testing for 2017 to 2026.

Ignition retard due to knock control 2 GENESIS_IGN_RETARD_KNOCK_2

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
(val × 0.75 − 191.25)
Range
-191.25 to 0 °
Unit
°

In testing for 2017 to 2026.

Ignition retard due to knock control 3 GENESIS_IGN_RETARD_KNOCK_3

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
(val × 0.75 − 191.25)
Range
-191.25 to 0 °
Unit
°

In testing for 2017 to 2026.

Ignition retard due to knock control 4 GENESIS_IGN_RETARD_KNOCK_4

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
(val × 0.75 − 191.25)
Range
-191.25 to 0 °
Unit
°

In testing for 2017 to 2026.

Ignition voltage GENESIS_IGN_VOLTAGE

  • Request22 E0 01
  • Service 22DID E001
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 120 to 135 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 10 ÷ 10000)
Range
0 to 65.535 V
Unit
V

In testing for 2017 to 2026.

Injection duration cylinder 1 GENESIS_CRUZ_INJ_DUR_1

  • Request22 E0 02
  • Service 22DID E002
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 1220.7)
Range
0 to 53 ms
Unit
ms

In testing for 2017 to 2026.

Injection duration cylinder 1 GENESIS_INJ_DUR_1

  • Request22 E0 02
  • Service 22DID E002
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 1220.7)
Range
0 to 53.68 s
Unit
s

In testing for 2017 to 2026.

Injection duration cylinder 2 GENESIS_CRUZ_INJ_DUR_2

  • Request22 E0 02
  • Service 22DID E002
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 1220.7)
Range
0 to 53 ms
Unit
ms

In testing for 2017 to 2026.

Injection duration cylinder 2 GENESIS_INJ_DUR_2

  • Request22 E0 02
  • Service 22DID E002
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 1220.7)
Range
0 to 53.68 s
Unit
s

In testing for 2017 to 2026.

Injection duration cylinder 3 GENESIS_CRUZ_INJ_DUR_3

  • Request22 E0 02
  • Service 22DID E002
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 1220.7)
Range
0 to 53 ms
Unit
ms

In testing for 2017 to 2026.

Injection duration cylinder 3 GENESIS_INJ_DUR_3

  • Request22 E0 02
  • Service 22DID E002
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 1220.7)
Range
0 to 53.68 s
Unit
s

In testing for 2017 to 2026.

Injection duration cylinder 4 GENESIS_CRUZ_INJ_DUR_4

  • Request22 E0 02
  • Service 22DID E002
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 1220.7)
Range
0 to 53 ms
Unit
ms

In testing for 2017 to 2026.

Injection duration cylinder 4 GENESIS_INJ_DUR_4

  • Request22 E0 02
  • Service 22DID E002
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 1220.7)
Range
0 to 53.68 s
Unit
s

In testing for 2017 to 2026.

Injection duration cylinder 5 GENESIS_INJ_DUR_5

  • Request22 E0 02
  • Service 22DID E002
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 240 to 255 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 1220.7)
Range
0 to 53.68 s
Unit
s

In testing for 2017 to 2026.

Injection duration cylinder 6 GENESIS_INJ_DUR_6

  • Request22 E0 02
  • Service 22DID E002
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 1220.7)
Range
0 to 53.68 s
Unit
s

In testing for 2017 to 2026.

Injection impulse 1, cylinder 1 GENESIS_INJ_IMPULSE_1_CYL_1

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 200 to 215 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 250)
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Injection impulse 1, cylinder 2 GENESIS_INJ_IMPULSE_1_CYL_2

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 216 to 231 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 250)
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Injection impulse 1, cylinder 3 GENESIS_INJ_IMPULSE_1_CYL_3

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 232 to 247 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 250)
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Injection impulse 1, cylinder 4 GENESIS_INJ_IMPULSE_1_CYL_4

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 248 to 263 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 250)
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Injection impulse 2, cylinder 1 GENESIS_INJ_IMPULSE_2_CYL_1

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 264 to 279 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 250)
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Injection impulse 2, cylinder 2 GENESIS_INJ_IMPULSE_2_CYL_2

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 280 to 295 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 250)
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Injection impulse 2, cylinder 3 GENESIS_INJ_IMPULSE_2_CYL_3

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 296 to 311 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 250)
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Injection impulse 2, cylinder 4 GENESIS_INJ_IMPULSE_2_CYL_4

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 312 to 327 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 250)
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Injection impulse 3, cylinder 1 GENESIS_INJ_IMPULSE_3_CYL_1

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 328 to 343 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 25)
Range
0 to 2621.4 ms
Unit
ms

In testing for 2017 to 2026.

Injection impulse 3, cylinder 2 GENESIS_INJ_IMPULSE_3_CYL_2

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 344 to 359 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 25)
Range
0 to 2621.4 ms
Unit
ms

In testing for 2017 to 2026.

Injection impulse 3, cylinder 3 GENESIS_INJ_IMPULSE_3_CYL_3

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 360 to 375 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 25)
Range
0 to 2621.4 ms
Unit
ms

In testing for 2017 to 2026.

Injection impulse 3, cylinder 4 GENESIS_INJ_IMPULSE_3_CYL_4

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 376 to 391 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 25)
Range
0 to 2621.4 ms
Unit
ms

In testing for 2017 to 2026.

Injector correction factor 1 GENESIS_CRUZ_INJ_CORR_FACTOR_1

  • Request22 E0 07
  • Service 22DID E007
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 2 ÷ 65535)
Range
0 to 2
Unit
Number

In testing for 2017 to 2026.

Injector correction factor 2 GENESIS_CRUZ_INJ_CORR_FACTOR_2

  • Request22 E0 07
  • Service 22DID E007
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 2 ÷ 65535)
Range
0 to 2
Unit
Number

In testing for 2017 to 2026.

Injector correction factor 3 GENESIS_CRUZ_INJ_CORR_FACTOR_3

  • Request22 E0 07
  • Service 22DID E007
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 240 to 255 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 2 ÷ 65535)
Range
0 to 2
Unit
Number

In testing for 2017 to 2026.

Injector correction factor 4 GENESIS_CRUZ_INJ_CORR_FACTOR_4

  • Request22 E0 07
  • Service 22DID E007
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 2 ÷ 65535)
Range
0 to 2
Unit
Number

In testing for 2017 to 2026.

Intake air temperature GENESIS_EIT

  • Request22 E0 01
  • Service 22DID E001
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 264 to 271 of the reply, 8 bits.

Formula
(val × 3 ÷ 4 − 48)
Range
-48 to 143 °C
Unit
°C

In testing for 2017 to 2026.

Intake air temperature GENESIS_IAT

  • Request22 E0 01
  • Service 22DID E001
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 264 to 271 of the reply, 8 bits.

Formula
(val ÷ 1.3333 − 48)
Range
0 to 143 °C
Unit
°C

In testing for 2017 to 2026.

Intake air temperature GENESIS_INTAKE_AIR_T

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 264 to 271 of the reply, 8 bits.

Formula
(val × 0.75 − 48)
Range
-48 to 143.25 °C
Unit
°C

In testing for 2017 to 2026.

Intake Air Temperature GENESIS_INTAKE_TEMP

  • Request22 E0 01
  • Service 22DID E001
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 264 to 271 of the reply, 8 bits.

Formula
(val ÷ 1.3333 − 48)
Range
0 to 143.254781 °C
Unit
°C

In testing for 2017 to 2026.

Intake cam oil control valve duty GENESIS_OIL_CTRL_VLV_IMPULSE

  • Request21 20
  • Service 21PID 20
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 144 to 151 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 2017 to 2026.

Intake camshaft position GENESIS_INT_CAM_POS

  • Request22 E0 20
  • Service 22DID E020
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 72 to 87 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val ÷ 128)
Range
-256 to 255 °
Unit
°

In testing for 2017 to 2026.

Intake camshaft position actual GENESIS_INTAKE_CAMSHAFT_POSITION_ACTUAL

  • Request21 17
  • Service 21PID 17
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 55 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val ÷ 128)
Range
-256 to 255 °
Unit
°

In testing for 2017 to 2026.

Intake camshaft position commanded GENESIS_INTAKE_CAMSHAFT_POSITION_COMMANDED

  • Request21 17
  • Service 21PID 17
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits. The value is signed.

Formula
(val ÷ 2)
Range
-64 to 63.5 °
Unit
°

In testing for 2017 to 2026.

Inverter temperature GENESIS_HVAC_INVERTER_T

  • Request22 01 02
  • Service 22DID 0102
  • Module7B3 → 7BB
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

In testing for 2017 to 2026.

Inverter temperature GENESIS_INVERTER_T

  • Request22 E0 01
  • Service 22DID E001
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 216 to 231 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val ÷ 100)
Range
-327.68 to 327.67 °C
Unit
°C

In testing for 2017 to 2026.

Inverter temperature GENESIS_INVERTER_T_7E3

  • Request22 01 02
  • Service 22DID 0102
  • Module7E3 → 7EB
  • Every5 s
  • Testing

Bits 96 to 103 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2017 to 2026.

Isolation resistance GENESIS_ISOLATION_RES

  • Request21 01
  • Service 21PID 01
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 456 to 471 of the reply, 16 bits.

Formula
val
Range
0 to 65535 kΩ
Unit
kΩ

In testing for 2017 to 2026.

Knock control adaptation value, cylinder 1 GENESIS_KNOCK_CTRL_ADPT_CYL_1

  • Request21 07
  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 552 to 559 of the reply, 8 bits. The value is signed.

Formula
(val × 3 ÷ 4)
Range
-96 to 95.25 °
Unit
°

In testing for 2017 to 2026.

Knock control adaptation value, cylinder 2 GENESIS_KNOCK_CTRL_ADPT_CYL_2

  • Request21 07
  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 560 to 567 of the reply, 8 bits. The value is signed.

Formula
(val × 3 ÷ 4)
Range
-96 to 95.25 °
Unit
°

In testing for 2017 to 2026.

Knock control adaptation value, cylinder 3 GENESIS_KNOCK_CTRL_ADPT_CYL_3

  • Request21 07
  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 568 to 575 of the reply, 8 bits. The value is signed.

Formula
(val × 3 ÷ 4)
Range
-96 to 95.25 °
Unit
°

In testing for 2017 to 2026.

Knock control adaptation value, cylinder 4 GENESIS_KNOCK_CTRL_ADPT_CYL_4

  • Request21 07
  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 576 to 583 of the reply, 8 bits. The value is signed.

Formula
(val × 3 ÷ 4)
Range
-96 to 95.25 °
Unit
°

In testing for 2017 to 2026.

Knock control adaptation value, cylinder 5 GENESIS_KNOCK_CTRL_ADPT_CYL_5

  • Request21 07
  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 584 to 591 of the reply, 8 bits. The value is signed.

Formula
(val × 3 ÷ 4)
Range
-96 to 95.25 °
Unit
°

In testing for 2017 to 2026.

Knock control adaptation value, cylinder 6 GENESIS_KNOCK_CTRL_ADPT_CYL_6

  • Request21 07
  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 592 to 599 of the reply, 8 bits. The value is signed.

Formula
(val × 3 ÷ 4)
Range
-96 to 95.25 °
Unit
°

In testing for 2017 to 2026.

Knock detected GENESIS_KNOCK_DETECTED

  • Request21 00
  • Service 21PID 00
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 200 to 207 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2026.

Knock detected GENESIS_KNOCK_DETECTED_7E0

  • Request22 E0 04
  • Service 22DID E004
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2026.

Knock learn cylinder 1 GENESIS_KNOCK_LEARN_1

  • Request22 E0 0A
  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 167 of the reply, 8 bits. The value is signed.

Formula
(val ÷ 5)
Range
-25.6 to 25.4 °
Unit
°

In testing for 2017 to 2026.

Knock learn cylinder 2 GENESIS_KNOCK_LEARN_2

  • Request22 E0 0A
  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 168 to 175 of the reply, 8 bits. The value is signed.

Formula
(val ÷ 5)
Range
-25.6 to 25.4 °
Unit
°

In testing for 2017 to 2026.

Knock learn cylinder 3 GENESIS_KNOCK_LEARN_3

  • Request22 E0 0A
  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 183 of the reply, 8 bits. The value is signed.

Formula
(val ÷ 5)
Range
-25.6 to 25.4 °
Unit
°

In testing for 2017 to 2026.

Knock learn cylinder 4 GENESIS_KNOCK_LEARN_4

  • Request22 E0 0A
  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits. The value is signed.

Formula
(val ÷ 5)
Range
-25.6 to 25.4 °
Unit
°

In testing for 2017 to 2026.

Knock retard cylinder #1 GENESIS_KNOCK_RETARD_CYLINDER_1

  • Request21 16
  • Service 21PID 16
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
(val × 0.75)
Range
0 to 191.25 °
Unit
°

In testing for 2017 to 2026.

Knock retard cylinder #2 GENESIS_KNOCK_RETARD_CYLINDER_2

  • Request21 16
  • Service 21PID 16
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
(val × 0.75)
Range
0 to 191.25 °
Unit
°

In testing for 2017 to 2026.

Knock retard cylinder #3 GENESIS_KNOCK_RETARD_CYLINDER_3

  • Request21 16
  • Service 21PID 16
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
(val × 0.75)
Range
0 to 191.25 °
Unit
°

In testing for 2017 to 2026.

Knock retard cylinder #4 GENESIS_KNOCK_RETARD_CYLINDER_4

  • Request21 16
  • Service 21PID 16
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
(val × 0.75)
Range
0 to 191.25 °
Unit
°

In testing for 2017 to 2026.

Knock retard cylinder 1 GENESIS_KNOCK_RETARD_1

  • Request22 E0 0A
  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits. The value is signed.

Formula
(val ÷ 5)
Range
-25.6 to 25.4 °
Unit
°

In testing for 2017 to 2026.

Knock retard cylinder 1 GENESIS_KNOCK_RETARD_CYL_1

  • Request21 07
  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 488 to 495 of the reply, 8 bits. The value is signed.

Formula
(val × 3 ÷ 4)
Range
-96 to 95.25 °
Unit
°

In testing for 2017 to 2026.

Knock retard cylinder 1 GENESIS_KNOCK_RETARD_CYL_1_V2

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
(val × 0.75 − 191.25)
Range
-191.25 to 0 °
Unit
°

In testing for 2017 to 2026.

Knock retard cylinder 1, alternate GENESIS_KNOCK_RETARD_1_E019

  • Request22 E0 19
  • Service 22DID E019
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
(val × 0.75 − 191.25)
Range
-191.25 to 0 °
Unit
°

In testing for 2017 to 2026.

Knock retard cylinder 1, alternate GENESIS_KNOCK_RETARD_CYL_1_ALT

  • Request21 0A
  • Service 21PID 0A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
(val ÷ 1.333333333)
Range
0 to 191.25 °
Unit
°

In testing for 2017 to 2026.

Knock retard cylinder 2 GENESIS_KNOCK_RETARD_2

  • Request22 E0 0A
  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 111 of the reply, 8 bits. The value is signed.

Formula
(val ÷ 5)
Range
-25.6 to 25.4 °
Unit
°

In testing for 2017 to 2026.

Knock retard cylinder 2 GENESIS_KNOCK_RETARD_CYL_2

  • Request21 07
  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 496 to 503 of the reply, 8 bits. The value is signed.

Formula
(val × 3 ÷ 4)
Range
-96 to 95.25 °
Unit
°

In testing for 2017 to 2026.

Knock retard cylinder 2 GENESIS_KNOCK_RETARD_CYL_2_V2

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
(val × 0.75 − 191.25)
Range
-191.25 to 0 °
Unit
°

In testing for 2017 to 2026.

Knock retard cylinder 2, alternate GENESIS_KNOCK_RETARD_2_E019

  • Request22 E0 19
  • Service 22DID E019
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
(val × 0.75 − 191.25)
Range
-191.25 to 0 °
Unit
°

In testing for 2017 to 2026.

Knock retard cylinder 2, alternate GENESIS_KNOCK_RETARD_CYL_2_ALT

  • Request21 0A
  • Service 21PID 0A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
(val ÷ 1.333333333)
Range
0 to 191.25 °
Unit
°

In testing for 2017 to 2026.

Knock retard cylinder 3 GENESIS_KNOCK_RETARD_3

  • Request22 E0 0A
  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits. The value is signed.

Formula
(val ÷ 5)
Range
-25.6 to 25.4 °
Unit
°

In testing for 2017 to 2026.

Knock retard cylinder 3 GENESIS_KNOCK_RETARD_CYL_3

  • Request21 07
  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 504 to 511 of the reply, 8 bits. The value is signed.

Formula
(val × 3 ÷ 4)
Range
-96 to 95.25 °
Unit
°

In testing for 2017 to 2026.

Knock retard cylinder 3 GENESIS_KNOCK_RETARD_CYL_3_V2

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
(val × 0.75 − 191.25)
Range
-191.25 to 0 °
Unit
°

In testing for 2017 to 2026.

Knock retard cylinder 3, alternate GENESIS_KNOCK_RETARD_3_E019

  • Request22 E0 19
  • Service 22DID E019
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
(val × 0.75 − 191.25)
Range
-191.25 to 0 °
Unit
°

In testing for 2017 to 2026.

Knock retard cylinder 3, alternate GENESIS_KNOCK_RETARD_CYL_3_ALT

  • Request21 0A
  • Service 21PID 0A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
(val ÷ 1.333333333)
Range
0 to 191.25 °
Unit
°

In testing for 2017 to 2026.

Knock retard cylinder 4 GENESIS_KNOCK_RETARD_4

  • Request22 E0 0A
  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 120 to 127 of the reply, 8 bits. The value is signed.

Formula
(val ÷ 5)
Range
-25.6 to 25.4 °
Unit
°

In testing for 2017 to 2026.

Knock retard cylinder 4 GENESIS_KNOCK_RETARD_CYL_4

  • Request21 07
  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 512 to 519 of the reply, 8 bits. The value is signed.

Formula
(val × 3 ÷ 4)
Range
-96 to 95.25 °
Unit
°

In testing for 2017 to 2026.

Knock retard cylinder 4 GENESIS_KNOCK_RETARD_CYL_4_V2

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
(val × 0.75 − 191.25)
Range
-191.25 to 0 °
Unit
°

In testing for 2017 to 2026.

Knock retard cylinder 4, alternate GENESIS_KNOCK_RETARD_4_E019

  • Request22 E0 19
  • Service 22DID E019
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
(val × 0.75 − 191.25)
Range
-191.25 to 0 °
Unit
°

In testing for 2017 to 2026.

Knock retard cylinder 4, alternate GENESIS_KNOCK_RETARD_CYL_4_ALT

  • Request21 0A
  • Service 21PID 0A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
(val ÷ 1.333333333)
Range
0 to 191.25 °
Unit
°

In testing for 2017 to 2026.

Knock retard cylinder 5 GENESIS_KNOCK_RETARD_CYL_5

  • Request21 07
  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 520 to 527 of the reply, 8 bits. The value is signed.

Formula
(val × 3 ÷ 4)
Range
-96 to 95.25 °
Unit
°

In testing for 2017 to 2026.

Knock retard cylinder 6 GENESIS_KNOCK_RETARD_CYL_6

  • Request21 07
  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 528 to 535 of the reply, 8 bits. The value is signed.

Formula
(val × 3 ÷ 4)
Range
-96 to 95.25 °
Unit
°

In testing for 2017 to 2026.

Lock switch GENESIS_LOCK_SWITCH

  • Request21 C0
  • Service 21PID C0
  • Module7E5
  • Every250 ms
  • Testing

Bit 151 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2017 to 2026.

Main injection volume GENESIS_MAIN_INJECTION_QTY

  • Request21 07
  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
(val × 0.392156863)
Range
0 to 100 L
Unit
L

In testing for 2017 to 2026.

Malfunction indicator GENESIS_MALFUNCTION_INDICATOR

  • Request21 C0
  • Service 21PID C0
  • Module7E5
  • Every250 ms
  • Testing

Bit 175 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2017 to 2026.

Mass air flow rate GENESIS_MAF_RATE

  • Request22 E0 10
  • Service 22DID E010
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 215 of the reply, 8 bits. The bytes are in little-endian order.

Formula
(val × 0.04239)
Range
0 to 10.8
Unit
Raw value

In testing for 2017 to 2026.

Max adaptation value for lower mechanical stop of the boost pressure actuator during engine running GENESIS_MAX_ADPT_LO_MECH_STOP_P

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 480 to 495 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 1.53 ÷ 10000)
Range
0 to 10.02 V
Unit
V

In testing for 2017 to 2026.

Max adaptation value for lower mechanical stop of the boost pressure actuator during engine stop GENESIS_MAX_ADPT_LO_MECH_P

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 464 to 479 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 1.53 ÷ 10000)
Range
0 to 10.02 V
Unit
V

In testing for 2017 to 2026.

Min adaptation value for lower mechanical stop of the boost pressure actuator during engine running GENESIS_MIN_ADPT_LO_MECH_STOP_P

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 512 to 527 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 1.53 ÷ 10000)
Range
0 to 10.02 V
Unit
V

In testing for 2017 to 2026.

Min adaptation value for lower mechanical stop of the boost pressure actuator during engine stop GENESIS_MIN_ADPT_LO_MECH_P

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 496 to 511 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 1.53 ÷ 10000)
Range
0 to 10.02 V
Unit
V

In testing for 2017 to 2026.

Misfire count #1 GENESIS_MIS_1

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 71 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Misfire count #2 GENESIS_MIS_2

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 72 to 87 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Misfire count #3 GENESIS_MIS_3

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 88 to 103 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Misfire count #4 GENESIS_MIS_4

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 119 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Misfires current total GENESIS_MIS_CURRENT_TOT

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 584 to 591 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2026.

Misfires current, cylinder 1 GENESIS_MIS_CURRENT_1

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 536 to 543 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2026.

Misfires current, cylinder 2 GENESIS_MIS_CURRENT_2

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 544 to 551 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2026.

Misfires current, cylinder 3 GENESIS_MIS_CURRENT_3

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 552 to 559 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2026.

Misfires current, cylinder 4 GENESIS_MIS_CURRENT_4

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 560 to 567 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2026.

Misfires current, cylinder 5 GENESIS_MIS_CURRENT_5

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 568 to 575 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2026.

Misfires current, cylinder 6 GENESIS_MIS_CURRENT_6

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 576 to 583 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2026.

Misfires, current, cylinder 1 GENESIS_MISFIRES_C1_CUR

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Misfires, current, cylinder 2 GENESIS_MISFIRES_C2_CUR

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Misfires, current, cylinder 3 GENESIS_MISFIRES_C3_CUR

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Misfires, current, cylinder 4 GENESIS_MISFIRES_C4_CUR

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Motor actual torque GENESIS_MOTOR_ACTUAL_TORQUE

  • Request22 E0 01
  • Service 22DID E001
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 168 to 183 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2017 to 2026.

Motor phase current GENESIS_MOTOR_PHASE_CURRENT_RMS

  • Request22 E0 01
  • Service 22DID E001
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 184 to 199 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
0 to 6553.5 A
Unit
A

In testing for 2017 to 2026.

Motor RPM GENESIS_MOTOR_RPM

  • Request22 E0 01
  • Service 22DID E001
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 136 to 151 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2017 to 2026.

Motor temperature GENESIS_MOTOR_T

  • Request22 E0 01
  • Service 22DID E001
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 200 to 215 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val ÷ 100)
Range
-327.68 to 327.67 °C
Unit
°C

In testing for 2017 to 2026.

Motor temperature GENESIS_MOTOR_T_7E3

  • Request22 01 02
  • Service 22DID 0102
  • Module7E3 → 7EB
  • Every5 s
  • Testing

Bits 88 to 95 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2017 to 2026.

Motor-driven power steering current GENESIS_MDPS_MOTOR_CURRENT

  • Request22 01 01
  • Service 22DID 0101
  • Module7D4 → 7DC
  • Every5 s
  • Testing

Bits 88 to 95 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 A
Unit
A

In testing for 2017 to 2026.

Niro_maximum deterioration GENESIS_MAX

  • Request21 05
  • Service 21PID 05
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 200 to 215 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 %
Unit
%

In testing for 2017 to 2026.

Niro_minimum deterioration GENESIS_MIN

  • Request21 05
  • Service 21PID 05
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 %
Unit
%

In testing for 2017 to 2026.

Nominal torque value GENESIS_NOMINAL_TORQUE_VALUE

  • Request22 E0 01
  • Service 22DID E001
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 152 to 167 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2017 to 2026.

NOx trap outlet pressure GENESIS_NOX_TRAP_OUTLET_P

  • Request22 ED 03
  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 288 to 295 of the reply, 8 bits.

Formula
(val × 3212451 ÷ 25000)
Range
0 to 32767.0002
Unit
Raw value

In testing for 2017 to 2026.

Oil pump PWM GENESIS_OIL_PMP_PWM

  • Request22 ED 13
  • Service 22DID ED13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 71 of the reply.

Formula
(val × 20 ÷ 51)
Range
0 to 0.392
Unit
Off or on

In testing for 2017 to 2026.

Operating time GENESIS_OP_TIME

  • Request21 01
  • Service 21PID 01
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 368 to 399 of the reply, 32 bits.

Formula
(val ÷ 3600)
Range
0 to 1193046
Unit
Raw value

In testing for 2017 to 2026.

Output speed GENESIS_OUTPUT_SPEED

  • Request21 A0
  • Service 21PID A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 88 to 103 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2017 to 2026.

Overheat protection, active GENESIS_OVERHEAT_PROTECTION

  • Request22 E0 14
  • Service 22DID E014
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 132 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2017 to 2026.

Oxygen sensor 1 bank 1 GENESIS_OXYGEN_SENSOR_11

  • Request21 02
  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 0.00521 − 0.2)
Range
-0.2 to 1.12 V
Unit
V

In testing for 2017 to 2026.

Oxygen sensor 2 bank 1 GENESIS_OXYGEN_SENSOR_21

  • Request21 02
  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
(val × 0.00521 − 0.2)
Range
-0.2 to 1.12 V
Unit
V

In testing for 2017 to 2026.

Parking sensor rear center left level GENESIS_CRUZ_PARKING_SENS_REAR

  • Request22 B0 09
  • Service 22DID B009
  • Module7A0 → 7A8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2026.

Parking sensor rear center right level GENESIS_CRUZ_PARKING_SENS_REAR_CENTER

  • Request22 B0 09
  • Service 22DID B009
  • Module7A0 → 7A8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2026.

Pilot injection volume GENESIS_PILOT_INJECTION_QTY

  • Request21 07
  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
val
Range
0 to 65535 L
Unit
L

In testing for 2017 to 2026.

Post injection volume GENESIS_POST_INJECTION_QTY

  • Request21 07
  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
val
Range
0 to 65535 L
Unit
L

In testing for 2017 to 2026.

Pressure sensor GENESIS_PRESSURE_SENSOR

  • Request21 C0
  • Service 21PID C0
  • Module7E5
  • Every250 ms
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
(val ÷ 4)
Range
0 to 63.75 bar
Unit
bar

In testing for 2017 to 2026.

Rail pressure control valve GENESIS_RAIL_P_CTRL_VLV

  • Request22 ED 01
  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 55 of the reply.

Formula
(val × 20 ÷ 51)
Range
0 to 0.3921
Unit
Off or on

In testing for 2017 to 2026.

Regeneration demand counter by soot load GENESIS_REGEN_DEMAND_CNT

  • Request22 ED 03
  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 320 to 327 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2026.

Requested torque GENESIS_REQUESTED_TORQUE

  • Request21 14
  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
(val × 0.001526)
Range
0 to 100 %
Unit
%

In testing for 2017 to 2026.

Requested torque limitation from traction control GENESIS_REQ_TQ_LIM_TRACTION

  • Request22 ED 06
  • Service 22DID ED06
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

In testing for 2017 to 2026.

Successful regeneration state GENESIS_SUCCESSFUL_REGEN_ST

  • Request22 ED 03
  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 424 to 431 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2017 to 2026.

Throttle position #1 GENESIS_THROTTLE_POS_1

Pelican can show this parameter as the throttle position.

  • Request21 14
  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val × 0.0244140625)
Range
-800 to 799 %
Unit
%

In testing for 2017 to 2026.

Throttle position #1 GENESIS_THROTTLE_POSITION__1

  • Request21 14
  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val × 0.0244140625)
Range
-800 to 799 %
Unit
%

In testing for 2017 to 2026.

Throttle position #2 GENESIS_THROTTLE_POSITION__2

  • Request21 14
  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 64 to 79 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val × 0.0244140625)
Range
-800 to 799 %
Unit
%

In testing for 2017 to 2026.

Timing advance #1 GENESIS_TIMING_ADVANCE_1

  • Request21 13
  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits. The value is signed.

Formula
(val × 0.75)
Range
-96 to 95.25 °
Unit
°

In testing for 2017 to 2026.

Timing advance #2 GENESIS_TIMING_ADVANCE_2

  • Request21 13
  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits. The value is signed.

Formula
(val × 0.75)
Range
-96 to 95.25 °
Unit
°

In testing for 2017 to 2026.

Timing advance #3 GENESIS_TIMING_ADVANCE_3

  • Request21 13
  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits. The value is signed.

Formula
(val × 0.75)
Range
-96 to 95.25 °
Unit
°

In testing for 2017 to 2026.

Timing advance #4 GENESIS_TIMING_ADVANCE_4

  • Request21 13
  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits. The value is signed.

Formula
(val × 0.75)
Range
-96 to 95.25 °
Unit
°

In testing for 2017 to 2026.

Torque converter slip GENESIS_TORQUE_CONVERTER_SLIP

  • Request21 A0
  • Service 21PID A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
(val ÷ 4 − 512)
Range
-512 to 15871.75 rpm
Unit
rpm

In testing for 2017 to 2026.

Torque converter slip GENESIS_TORQUE_CONVERTER_SLIP_V2

  • Request22 01 A0
  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
(val ÷ 4 − 512)
Range
-512 to 15871.75 rpm
Unit
rpm

In testing for 2017 to 2026.

Torque converter slip GENESIS_TQ_CONV_SLIP

  • Request21 A0
  • Service 21PID A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
(val ÷ 4 − 512)
Range
-512 to 15871.75 rpm
Unit
rpm

In testing for 2017 to 2026.

Torque, actual GENESIS_TQ_ACT

  • Request21 05
  • Service 21PID 05
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 61 ÷ 40000)
Range
0 to 99.94 %
Unit
%

In testing for 2017 to 2026.

Total sulfur mass GENESIS_TOT_SULFUR_MASS

  • Request22 ED 29
  • Service 22DID ED29
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 15259 ÷ 100000)
Range
0 to 9999
Unit
Raw value

In testing for 2017 to 2026.

Transmission fluid temperature GENESIS_ATF_T_7E0

Pelican can show this parameter as the transmission fluid temperature.

  • Request21 A0
  • Service 21PID A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 264 to 271 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2017 to 2026.

Turbine speed GENESIS_TURBINE_SPEED

  • Request21 A0
  • Service 21PID A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 72 to 87 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2017 to 2026.

Turbo boost gauge pressure GENESIS_TURBO_BOOST

  • Request22 E0 21
  • Service 22DID E021
  • Module7E0 → 7E8
  • Every100 ms
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
(val ÷ 831.556909 − 12)
Range
-10 to 66.81 psi
Unit
psi

In testing for 2017 to 2026.

Turbo boost pressure GENESIS_CRUZ_TB_PRES

  • Request22 E0 21
  • Service 22DID E021
  • Module7E0 → 7E8
  • Every100 ms
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
(val × 0.008291)
Range
0 to 543 kPa
Unit
kPa

In testing for 2017 to 2026.

Turbo boost pressure GENESIS_TB_PRES

  • Request22 E0 21
  • Service 22DID E021
  • Module7E0 → 7E8
  • Every100 ms
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
(val × 0.008291)
Range
0 to 543.350685 kPa
Unit
kPa

In testing for 2017 to 2026.

Turbo boost pressure GENESIS_TURBO_BOOST_P

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 829.1 ÷ 10000)
Range
0 to 5433
Unit
Raw value

In testing for 2017 to 2026.

Turbo boost pressure GENESIS_TURBO_BOOST_P_7E0

  • Request21 21
  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
(val × 0.008291)
Range
0 to 543
Unit
Number

In testing for 2017 to 2026.

Variable valve timing temperature GENESIS_CVVT_T

Continuously variable valve timing temperature.

  • Request21 18
  • Service 21PID 18
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 272 to 279 of the reply, 8 bits.

Formula
(val − 48)
Range
-48 to 207 °C
Unit
°C

In testing for 2017 to 2026.

Waste gate duty GENESIS_CRUZ_WG_DUTY

  • Request22 E0 21
  • Service 22DID E021
  • Module7E0 → 7E8
  • Every100 ms
  • Testing

Bits 408 to 423 of the reply, 16 bits.

Formula
(val × 0.00305176)
Range
0 to 199 %
Unit
%

In testing for 2017 to 2026.

Waste gate duty GENESIS_WASTE_GATE_DUTY

  • Request21 21
  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 408 to 423 of the reply, 16 bits.

Formula
(val × 0.00305176)
Range
0 to 199 %
Unit
%

In testing for 2017 to 2026.

Waste gate duty GENESIS_WG_DUTY

  • Request22 E0 21
  • Service 22DID E021
  • Module7E0 → 7E8
  • Every100 ms
  • Testing

Bits 408 to 423 of the reply, 16 bits.

Formula
(val × 200 ÷ 65535)
Range
0 to 200 %
Unit
%

In testing for 2017 to 2026.

Waste gate position GENESIS_WASTE_GATE_POS

  • Request21 21
  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 424 to 439 of the reply, 16 bits.

Formula
(val × 0.00610352)
Range
0 to 399 %
Unit
%

In testing for 2017 to 2026.

Waste gate position GENESIS_WG_POS

  • Request22 E0 21
  • Service 22DID E021
  • Module7E0 → 7E8
  • Every100 ms
  • Testing

Bits 424 to 439 of the reply, 16 bits.

Formula
(val × 0.00610352)
Range
0 to 399.9941832 %
Unit
%

In testing for 2017 to 2026.

Waste gate position GENESIS_WG_POSITION

  • Request22 E0 21
  • Service 22DID E021
  • Module7E0 → 7E8
  • Every100 ms
  • Testing

Bits 424 to 439 of the reply, 16 bits.

Formula
(val × 400 ÷ 65535)
Range
0 to 400 %
Unit
%

In testing for 2017 to 2026.

Waste gate set point GENESIS_WG_SETPOINT

  • Request22 E0 21
  • Service 22DID E021
  • Module7E0 → 7E8
  • Every100 ms
  • Testing

Bits 440 to 455 of the reply, 16 bits.

Formula
(val × 400 ÷ 65535)
Range
0 to 100 %
Unit
%

In testing for 2017 to 2026.

Waste gate setpoint GENESIS_WG_SP

  • Request22 E0 21
  • Service 22DID E021
  • Module7E0 → 7E8
  • Every100 ms
  • Testing

Bits 440 to 455 of the reply, 16 bits.

Formula
(val × 0.00610352)
Range
0 to 399.9941832 %
Unit
%

In testing for 2017 to 2026.

Waste gate target GENESIS_WASTE_GATE_TGT

  • Request21 21
  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 440 to 455 of the reply, 16 bits.

Formula
(val × 0.00610352)
Range
0 to 399 %
Unit
%

In testing for 2017 to 2026.

Waste gate voltage GENESIS_CRUZ_WG_V

  • Request22 E0 21
  • Service 22DID E021
  • Module7E0 → 7E8
  • Every100 ms
  • Testing

Bits 392 to 407 of the reply, 16 bits.

Formula
(val × 0.000152588)
Range
0 to 9.99 V
Unit
V

In testing for 2017 to 2026.

Waste gate voltage GENESIS_WG_V

  • Request22 E0 21
  • Service 22DID E021
  • Module7E0 → 7E8
  • Every100 ms
  • Testing

Bits 392 to 407 of the reply, 16 bits.

Formula
(val × 0.000152588)
Range
0 to 9.99985458 V
Unit
V

In testing for 2017 to 2026.

Waste gate voltage GENESIS_WG_VOLTAGE

  • Request22 E0 21
  • Service 22DID E021
  • Module7E0 → 7E8
  • Every100 ms
  • Testing

Bits 392 to 407 of the reply, 16 bits.

Formula
(val × 10 ÷ 65535)
Range
0 to 10 V
Unit
V

In testing for 2017 to 2026.

Wastegate control PWM, wastegate actuator GENESIS_WASTEGATE_CTRL_PWM

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 416 to 431 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val × 100 ÷ 32767)
Range
-100 to 100 %
Unit
%

In testing for 2017 to 2026.

Wastegate position target, wastegate actuator GENESIS_WASTEGATE_POS_TGT

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 448 to 463 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val × 200 ÷ 32767)
Range
-200 to 200 %
Unit
%

In testing for 2017 to 2026.

Wastegate position, wastegate actuator GENESIS_WASTEGATE_POS

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 432 to 447 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val × 200 ÷ 32767)
Range
-200 to 200 %
Unit
%

In testing for 2017 to 2026.

Wide open throttle GENESIS_WIDE_OPEN_THROTTLE

  • Request22 E0 04
  • Service 22DID E004
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2026.

Engine › Misfires

Emission-relevant misfires, cylinder #1 GENESIS_MIS_CNT_EMIS_1

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Emission-relevant misfires, cylinder #2 GENESIS_MIS_CNT_EMIS_2

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Emission-relevant misfires, cylinder #3 GENESIS_MIS_CNT_EMIS_3

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Emission-relevant misfires, cylinder #4 GENESIS_MIS_CNT_EMIS_4

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Misfires harmful for catalyst cylinder 1 GENESIS_MIS_CAT_1

  • Request21 1D
  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Misfires harmful for catalyst cylinder 2 GENESIS_MIS_CAT_2

  • Request21 1D
  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Misfires harmful for catalyst cylinder 3 GENESIS_MIS_CAT_3

  • Request21 1D
  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Misfires harmful for catalyst cylinder 4 GENESIS_MIS_CAT_4

  • Request21 1D
  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Misfires total counter, all cylinders GENESIS_MIS_CNT_ALL

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 432 to 447 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Misfires total counter, cylinder #1 GENESIS_MIS_CNT_1

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Misfires total counter, cylinder #2 GENESIS_MIS_CNT_2

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Misfires total counter, cylinder #3 GENESIS_MIS_CNT_3

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Misfires total counter, cylinder #4 GENESIS_MIS_CNT_4

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Misfires, cylinder 1 GENESIS_MIS_1_7E0

  • Request21 1D
  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Misfires, cylinder 2 GENESIS_MIS_2_7E0

  • Request21 1D
  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Misfires, cylinder 3 GENESIS_MIS_3_7E0

  • Request21 1D
  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Misfires, cylinder 4 GENESIS_MIS_4_7E0

  • Request21 1D
  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Engine › Unknown

Engine status byte GENESIS_E004_BYTE0

  • Request22 E0 04
  • Service 22DID E004
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100
Unit
Number

In testing for 2017 to 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.