Battery parameters
The Kia Optima has 28 battery parameters.
● Confirmed◆ In testing○ Supported× Not supported
12v battery voltage OPTIMA_VPWRConfirmed
Pelican can show this parameter as the starter battery voltage.
- Request
22 B0 02 - Service 22
DID B002 - Module
7C6 → 7CE - Every
5 s - Testing for 2000 to 2018, 2020 to 2026
Example reply from a 2019 Kia Optima.
Bits 40 to 47 of the reply, 8 bits.
0xB2 = 178 → (178 ÷ 12.8) = 13.90625 V
- Formula
(val ÷ 12.8)- Range
- 0 to 18 V
- Unit
- V
Confirmed for 2019. In testing for 2000 to 2018, 2020 to 2026.
Battery capacity, battery sensor OPTIMA_BAT_CAP_BATSENS
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 160 to 167 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 Ah
- Unit
- Ah
In testing for 2000 to 2018, 2020 to 2026. Not supported for 2019.
Battery charge flag, battery sensor OPTIMA_BAT_CHG_FLAG_BATSENS
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bit 183 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2000 to 2018, 2020 to 2026. Not supported for 2019.
Battery current OPTIMA_BAT_CURRENT
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 256 to 271 of the reply, 16 bits. The value is signed.
- Formula
(val × 1000 ÷ 10000)- Range
- -3276.8 to 3276.7 A
- Unit
- A
In testing for 2000 to 2018, 2020 to 2026. Not supported for 2019.
Battery current, battery sensor OPTIMA_BAT_CURRENT_BATSENS
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 A
- Unit
- A
In testing for 2000 to 2018, 2020 to 2026. Not supported for 2019.
Battery health aging flag, battery sensor OPTIMA_BAT_HEALTH_AGING
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bit 182 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2000 to 2018, 2020 to 2026. Not supported for 2019.
Battery is in use to crank the engine flag, battery sensor OPTIMA_BAT_CRANK_ENG_FLAG
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bit 181 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2000 to 2018, 2020 to 2026. Not supported for 2019.
Battery quiescent current flag, battery sensor OPTIMA_BAT_QUIESCENT
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bit 180 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2000 to 2018, 2020 to 2026. Not supported for 2019.
Battery sensor invalid condition flag, battery sensor OPTIMA_BATSENS_INVALID_COND
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bit 179 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2000 to 2018, 2020 to 2026. Not supported for 2019.
Battery state of charge, battery sensor OPTIMA_BAT_ST_CHG_BATSENS
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2000 to 2018, 2020 to 2026. Not supported for 2019.
Battery state of function, battery sensor OPTIMA_BAT_ST_FUNCTION
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val × 12.75 ÷ 255)- Range
- 0 to 12.75 V
- Unit
- V
In testing for 2000 to 2018, 2020 to 2026. Not supported for 2019.
Battery state of health, battery sensor OPTIMA_BAT_ST_HEALTH
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2000 to 2018, 2020 to 2026. Not supported for 2019.
Battery temperature OPTIMA_BAT_T
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
(val ÷ 2)- Range
- 0 to 32767.5 °C
- Unit
- °C
In testing for 2000 to 2018, 2020 to 2026. Not supported for 2019.
Battery temperature, battery sensor OPTIMA_BAT_T_BATSENS
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- -40 to 87.5 °C
- Unit
- °C
In testing for 2000 to 2018, 2020 to 2026. Not supported for 2019.
Battery voltage OPTIMA_BAT_V
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
(val × 10 ÷ 10000 + 6)- Range
- 0 to 71.535 V
- Unit
- V
In testing for 2000 to 2018, 2020 to 2026. Not supported for 2019.
Battery voltage, battery sensor OPTIMA_BAT_V_BATSENS
Pelican can show this parameter as the starter battery voltage.
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val × 12.75 ÷ 255 + 6)- Range
- 0 to 18.75 V
- Unit
- V
In testing for 2000 to 2018, 2020 to 2026. Not supported for 2019.
Control module voltage OPTIMA_CONTROL_MODULE_VOLTAGE
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 V
- Unit
- V
In testing for 2000 to 2018, 2020 to 2026. Not supported for 2019.
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Request
01 42 - Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65535 V
- Unit
- V
Confirmed for 2012 to 2015. Supported for 2011, 2016 to 2020.
Control module voltage after ignition OPTIMA_CONTROL_MODULE_VOLTAGE_AFTER_IGNITION
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 V
- Unit
- V
In testing for 2000 to 2018, 2020 to 2026. Not supported for 2019.
Coolant temperature sensor voltage OPTIMA_COOLANT_T_SENSOR_VOLTAGE
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 184 to 199 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 0.0048828125)- Range
- 0 to 319.9951 V
- Unit
- V
In testing for 2000 to 2018, 2020 to 2026. Not supported for 2019.
IAT sensor voltage OPTIMA_IAT_SENSOR_VOLTAGE
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 248 to 263 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 0.0048828125)- Range
- 0 to 319.9951 V
- Unit
- V
In testing for 2000 to 2018, 2020 to 2026. Not supported for 2019.
Manifold absolute pressure sensor voltage OPTIMA_MAP_SENSOR_VOLTAGE
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 112 to 127 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 0.0048828125)- Range
- 0 to 319.9951 V
- Unit
- V
In testing for 2000 to 2018, 2020 to 2026. Not supported for 2019.
Relative accelerator pedal position voltage OPTIMA_RELATIVE_ACCELERATOR_PEDAL_POSITION_VOLTAGE
- Request
21 14 - Service 21
PID 14 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 112 to 127 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val ÷ 5)- Range
- -6553.6 to 6553.4 V
- Unit
- V
In testing for 2000 to 2018, 2020 to 2026. Not supported for 2019.
Response error from battery sensor flag, battery sensor OPTIMA_RESPONSE_ERROR
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bit 178 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2000 to 2018, 2020 to 2026. Not supported for 2019.
Throttle position sensor voltage #1 OPTIMA_THROTTLE_POSITION_SENSOR_VOLTAGE__1
- Request
21 14 - Service 21
PID 14 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 360 to 375 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 0.0012207031)- Range
- 0 to 79 V
- Unit
- V
In testing for 2000 to 2018, 2020 to 2026. Not supported for 2019.
Throttle position sensor voltage #2 OPTIMA_THROTTLE_POSITION_SENSOR_VOLTAGE__2
- Request
21 14 - Service 21
PID 14 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 0.0012207031)- Range
- 0 to 79 V
- Unit
- V
In testing for 2000 to 2018, 2020 to 2026. Not supported for 2019.
Waste gate voltage OPTIMA_WASTE_GATE_V
- Request
21 21 - Service 21
PID 21 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 392 to 407 of the reply, 16 bits.
- Formula
(val × 0.000152588)- Range
- 0 to 9.99 V
- Unit
- V
In testing for 2000 to 2018, 2020 to 2026. Not supported for 2019.
Wastegate position voltage OPTIMA_WASTEGATE_POS_V
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 400 to 415 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val × 1.53 ÷ 10000)- Range
- -5.01 to 5.01 V
- Unit
- V