Battery parameters
The MG Comet has 246 battery parameters.
● Confirmed◆ In testing○ Supported× Not supported
Charge current limit MG_CHG_A_LIMIT
- Request
22 B7 12 - Service 22
DID B712 - Module
7E3 → 7EB - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 A
- Unit
- A
In testing for 2023 to 2026.
Charger connected MG_CHG_CONNECTED
Pelican can show this parameter as the plug state.
- Request
22 B7 1B - Service 22
DID B71B - Module
7E3 → 7EB - Every
5 s - Testing
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
In testing for 2023 to 2026.
High voltage battery current MG_HBAT_C
- Request
22 B0 43 - Service 22
DID B043 - Module
781 → 789 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 40 − 1000)- Range
- -1000 to 638.375 mA
- Unit
- mA
In testing for 2023 to 2026.
High voltage battery voltage MG_HBAT_V
- Request
22 B0 42 - Service 22
DID B042 - Module
781 → 789 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 300 to 450 V
- Unit
- V
In testing for 2023 to 2026.
Highest cell voltage MG_HVBAT_CELL_V_MAX
- Request
22 B0 58 - Service 22
DID B058 - Module
7E5 → 7ED - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2023 to 2026.
Highest cell voltage MG_HVBAT_CELL_V_MAX_GEN1
- Request
22 B0 58 - Service 22
DID B058 - Module
781 → 789 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2023 to 2026.
HV battery coolant temperature MG_HVBAT_COOLANT_TEMP
- Request
22 B0 5C - Service 22
DID B05C - Module
7DF → 7ED - Every
60 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery coolant temperature MG_HVBAT_COOLANT_TEMP_GEN1
- Request
22 B0 5C - Service 22
DID B05C - Module
781 → 789 - Every
60 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- -40 to 87.5 °C
- Unit
- °C
In testing for 2023 to 2026.
HV battery coolant temperature MG_HVBAT_COOLANT_TEMP_V2
- Request
22 B0 5C - Service 22
DID B05C - Module
7E5 → 7ED - Every
60 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- -40 to 87.5 °C
- Unit
- °C
In testing for 2023 to 2026.
HV battery current MG_HVBAT_CURRENT
- Request
22 B0 43 - Service 22
DID B043 - Module
7DF → 7ED - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 40 − 1000)- Range
- 0 to 250 A
- Unit
- A
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery current MG_HVBAT_CURRENT_V2
- Request
22 B0 43 - Service 22
DID B043 - Module
7E5 → 7ED - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.025 − 1000)- Range
- 0 to 250 A
- Unit
- A
In testing for 2023 to 2026.
HV battery error code MG_HVBAT_ERR
- Request
22 B0 47 - Service 22
DID B047 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
HV battery error code MG_HVBAT_ERR_GEN1
- Request
22 B0 47 - Service 22
DID B047 - Module
781 → 789 - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
HV battery health MG_HVBAT_SOH
Pelican can show this parameter as the state of health.
- Request
22 B0 61 - Service 22
DID B061 - Module
7DF → 7ED - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery health MG_HVBAT_SOH_V2
Pelican can show this parameter as the state of health.
- Request
22 B0 61 - Service 22
DID B061 - Module
7E5 → 7ED - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2023 to 2026.
HV battery is charging? MG_HVBAT_CHARGING
Pelican can show this parameter as the charging state.
- Request
22 B0 48 - Service 22
DID B048 - Module
7DF → 7ED - Every
1 s - Testing
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery is charging? MG_HVBAT_CHARGING_V2
- Request
22 B0 48 - Service 22
DID B048 - Module
7E5 → 7ED - Every
1 s - Testing
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 2023 to 2026.
HV battery main relay B state MG_HVBAT_RELAY_B
- Request
22 B0 49 - Service 22
DID B049 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
HV battery main relay B state MG_HVBAT_RELAY_B_GEN1
- Request
22 B0 49 - Service 22
DID B049 - Module
781 → 789 - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
HV battery main relay G state MG_HVBAT_RELAY_G
- Request
22 B0 4A - Service 22
DID B04A - Module
7E5 → 7ED - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
HV battery main relay G state MG_HVBAT_RELAY_G_GEN1
- Request
22 B0 4A - Service 22
DID B04A - Module
781 → 789 - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
HV battery main relay P state MG_HVBAT_RELAY_P
- Request
22 B0 52 - Service 22
DID B052 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
HV battery main relay P state MG_HVBAT_RELAY_P_GEN1
- Request
22 B0 52 - Service 22
DID B052 - Module
781 → 789 - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
HV battery range count MG_HVBAT_RANGE_RAW
- Request
22 B0 CE - Service 22
DID B0CE - Module
7E5 → 7ED - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2023 to 2026.
HV battery range count MG_HVBAT_RANGE_RAW_GEN1
- Request
22 B0 CE - Service 22
DID B0CE - Module
781 → 789 - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2023 to 2026.
HV battery temperature MG_HVBAT_TEMP
- Request
22 B0 56 - Service 22
DID B056 - Module
7DF → 7ED - Every
60 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery temperature MG_HVBAT_TEMP_GEN1
- Request
22 B0 56 - Service 22
DID B056 - Module
781 → 789 - Every
60 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- -40 to 87.5 °C
- Unit
- °C
In testing for 2023 to 2026.
HV battery temperature MG_HVBAT_TEMP_V2
- Request
22 B0 56 - Service 22
DID B056 - Module
7E5 → 7ED - Every
60 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- -40 to 87.5 °C
- Unit
- °C
In testing for 2023 to 2026.
HV battery voltage MG_HVBAT_VOLTAGE
- Request
22 B0 42 - Service 22
DID B042 - Module
7DF → 7ED - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 500 V
- Unit
- V
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery voltage MG_HVBAT_VOLTAGE_V2
- Request
22 B0 42 - Service 22
DID B042 - Module
7E5 → 7ED - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.25)- Range
- 0 to 500 V
- Unit
- V
In testing for 2023 to 2026.
HV battery voltage, vehicle control unit MG_HVBAT_V_VCU
- Request
22 B7 05 - Service 22
DID B705 - Module
7E3 → 7EB - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 2023 to 2026.
HV contactor closed MG_HV_CONTACTOR
- Request
22 B7 03 - Service 22
DID B703 - Module
7E3 → 7EB - Every
5 s - Testing
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
In testing for 2023 to 2026.
Is charging MG_IS_CHARGING
Pelican can show this parameter as the charging state.
- Request
22 B0 48 - Service 22
DID B048 - Module
781 → 789 - Every
1 s - Testing
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
In testing for 2023 to 2026.
Is DC fast charging MG_IS_DCFC
- Request
22 B0 48 - Service 22
DID B048 - Module
781 → 789 - Every
1 s - Testing
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
In testing for 2023 to 2026.
Knock sensor voltage MG_KNOCK_SNS_V
- Request
22 B1 40 - Service 22
DID B140 - Module
7E0 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 5 ÷ 255)- Range
- 0 to 5 V
- Unit
- V
In testing for 2023 to 2026.
Lowest cell voltage MG_HVBAT_CELL_V_MIN
- Request
22 B0 59 - Service 22
DID B059 - Module
7E5 → 7ED - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2023 to 2026.
Lowest cell voltage MG_HVBAT_CELL_V_MIN_GEN1
- Request
22 B0 59 - Service 22
DID B059 - Module
781 → 789 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2023 to 2026.
State of charge MG_SOC
Pelican can show this parameter as the state of charge.
- Request
22 B0 46 - Service 22
DID B046 - Module
781 → 789 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 100 %
- Unit
- %
In testing for 2023 to 2026.
State of health MG_SOH
Pelican can show this parameter as the state of health.
- Request
22 B0 61 - Service 22
DID B061 - Module
781 → 789 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2023 to 2026.
Battery › EVCC
Charging MG_EVCC_CHARGING
- Request
22 B0 0F - Service 22
DID B00F - Module
7DF → 7EC - Every
4 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2023, 2025 to 2026. Not supported for 2024.
Charging MG_EVCC_CHARGING_V2
- Request
22 B0 0F - Service 22
DID B00F - Module
7E4 → 7EC - Every
4 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Current MG_EVCC_CURRENT
- Request
22 B0 01 - Service 22
DID B001 - Module
7DF → 7EC - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 5 − 409.6)- Range
- 0 to 250 A
- Unit
- A
In testing for 2023, 2025 to 2026. Not supported for 2024.
Current MG_EVCC_CURRENT_V2
- Request
22 B0 01 - Service 22
DID B001 - Module
7E4 → 7EC - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.2 − 409.6)- Range
- 0 to 250 A
- Unit
- A
In testing for 2023 to 2026.
Max current MG_EVCC_MAX_CURRENT
- Request
22 B0 03 - Service 22
DID B003 - Module
7DF → 7EC - Every
180 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 0.434782609)- Range
- 0 to 110.869565 A
- Unit
- A
In testing for 2023, 2025 to 2026. Not supported for 2024.
Max Current MG_EVCC_MAX_CURRENT_V2
- Request
22 B0 03 - Service 22
DID B003 - Module
7E4 → 7EC - Every
180 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 0.434782609)- Range
- 0 to 110.869565 A
- Unit
- A
In testing for 2023 to 2026.
Voltage MG_EVCC_VOLTAGE
- Request
22 B0 10 - Service 22
DID B010 - Module
7DF → 7EC - Every
4 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 97)- Range
- 0 to 675.618556 V
- Unit
- V
In testing for 2023, 2025 to 2026. Not supported for 2024.
Voltage MG_EVCC_VOLTAGE_V2
- Request
22 B0 10 - Service 22
DID B010 - Module
7E4 → 7EC - Every
4 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0103092783)- Range
- 0 to 675.618553 V
- Unit
- V
In testing for 2023 to 2026.
Battery › Internal
BMS Status MG_BMS_STATUS
- Request
22 B0 48 - Service 22
DID B048 - Module
7DF → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery bus voltage MG_HVBAT_BUS_VOLTAGE
- Request
22 B0 41 - Service 22
DID B041 - Module
7DF → 7ED - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 1000 V
- Unit
- V
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery bus voltage MG_HVBAT_BUS_VOLTAGE_GEN1
- Request
22 B0 41 - Service 22
DID B041 - Module
781 → 789 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 1000 V
- Unit
- V
In testing for 2023 to 2026.
HV battery bus voltage MG_HVBAT_BUS_VOLTAGE_V2
- Request
22 B0 41 - Service 22
DID B041 - Module
7E5 → 7ED - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 1000 V
- Unit
- V
In testing for 2023 to 2026.
HV battery internal resistance MG_HVBAT_RESISTANCE
- Request
22 B0 45 - Service 22
DID B045 - Module
7DF → 7ED - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2)- Range
- 0 to 32767.5
- Unit
- Number
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery internal resistance MG_HVBAT_RESISTANCE_V2
- Request
22 B0 45 - Service 22
DID B045 - Module
7E5 → 7ED - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.5)- Range
- 0 to 32767.5
- Unit
- Number
In testing for 2023 to 2026.
HV battery raw charge MG_HVBAT_RAW_SOC
HV battery raw charge
- Request
22 B0 46 - Service 22
DID B046 - Module
7DF → 7ED - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 100 %
- Unit
- %
In testing for 2023, 2025 to 2026. Not supported for 2024.
Battery › Modules › 01
HV battery module 01 max temperature MG_HVBAT_CMU01_MAXTEMP
- Request
22 B0 01 - Service 22
DID B001 - Module
7DF → 7EC - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 01 max temperature MG_HVBAT_CMU01_MAXTEMP_V2
- Request
22 B0 01 - Service 22
DID B001 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2023 to 2026.
HV battery module 01 max voltage MG_HVBAT_CMU01_MAXVOLT
- Request
22 B0 01 - Service 22
DID B001 - Module
7DF → 7EC - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 01 max voltage MG_HVBAT_CMU01_MAXVOLT_V2
- Request
22 B0 01 - Service 22
DID B001 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023 to 2026.
HV battery module 01 min temperature MG_HVBAT_CMU01_MINTEMP
- Request
22 B0 01 - Service 22
DID B001 - Module
7DF → 7EC - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 01 min temperature MG_HVBAT_CMU01_MINTEMP_V2
- Request
22 B0 01 - Service 22
DID B001 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2023 to 2026.
HV battery module 01 min voltage MG_HVBAT_CMU01_MINVOLT
- Request
22 B0 01 - Service 22
DID B001 - Module
7DF → 7EC - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 01 min voltage MG_HVBAT_CMU01_MINVOLT_V2
- Request
22 B0 01 - Service 22
DID B001 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023 to 2026.
Battery › Modules › 02
HV battery module 02 max temperature MG_HVBAT_CMU02_MAXTEMP
- Request
22 B0 09 - Service 22
DID B009 - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 02 max temperature MG_HVBAT_CMU02_MAXTEMP_V2
- Request
22 B0 09 - Service 22
DID B009 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2023 to 2026.
HV battery module 02 max voltage MG_HVBAT_CMU02_MAXVOLT
- Request
22 B0 09 - Service 22
DID B009 - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 02 max voltage MG_HVBAT_CMU02_MAXVOLT_V2
- Request
22 B0 09 - Service 22
DID B009 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023 to 2026.
HV battery module 02 min temperature MG_HVBAT_CMU02_MINTEMP
- Request
22 B0 09 - Service 22
DID B009 - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 02 min temperature MG_HVBAT_CMU02_MINTEMP_V2
- Request
22 B0 09 - Service 22
DID B009 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2023 to 2026.
HV battery module 02 min voltage MG_HVBAT_CMU02_MINVOLT
- Request
22 B0 09 - Service 22
DID B009 - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 02 min voltage MG_HVBAT_CMU02_MINVOLT_V2
- Request
22 B0 09 - Service 22
DID B009 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023 to 2026.
Battery › Modules › 03
HV battery module 03 max temperature MG_HVBAT_CMU03_MAXTEMP
- Request
22 B0 11 - Service 22
DID B011 - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 03 max temperature MG_HVBAT_CMU03_MAXTEMP_V2
- Request
22 B0 11 - Service 22
DID B011 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2023 to 2026.
HV battery module 03 max voltage MG_HVBAT_CMU03_MAXVOLT
- Request
22 B0 11 - Service 22
DID B011 - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 03 max voltage MG_HVBAT_CMU03_MAXVOLT_V2
- Request
22 B0 11 - Service 22
DID B011 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023 to 2026.
HV battery module 03 min temperature MG_HVBAT_CMU03_MINTEMP
- Request
22 B0 11 - Service 22
DID B011 - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 03 min temperature MG_HVBAT_CMU03_MINTEMP_V2
- Request
22 B0 11 - Service 22
DID B011 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2023 to 2026.
HV battery module 03 min voltage MG_HVBAT_CMU03_MINVOLT
- Request
22 B0 11 - Service 22
DID B011 - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 03 min voltage MG_HVBAT_CMU03_MINVOLT_V2
- Request
22 B0 11 - Service 22
DID B011 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023 to 2026.
Battery › Modules › 04
HV battery module 04 max temperature MG_HVBAT_CMU04_MAXTEMP
- Request
22 B0 19 - Service 22
DID B019 - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 04 max temperature MG_HVBAT_CMU04_MAXTEMP_V2
- Request
22 B0 19 - Service 22
DID B019 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2023 to 2026.
HV battery module 04 max voltage MG_HVBAT_CMU04_MAXVOLT
- Request
22 B0 19 - Service 22
DID B019 - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 04 max voltage MG_HVBAT_CMU04_MAXVOLT_V2
- Request
22 B0 19 - Service 22
DID B019 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023 to 2026.
HV battery module 04 min temperature MG_HVBAT_CMU04_MINTEMP
- Request
22 B0 19 - Service 22
DID B019 - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 04 min temperature MG_HVBAT_CMU04_MINTEMP_V2
- Request
22 B0 19 - Service 22
DID B019 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2023 to 2026.
HV battery module 04 min voltage MG_HVBAT_CMU04_MINVOLT
- Request
22 B0 19 - Service 22
DID B019 - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 04 min voltage MG_HVBAT_CMU04_MINVOLT_V2
- Request
22 B0 19 - Service 22
DID B019 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023 to 2026.
Battery › Modules › 05
HV battery module 05 max temperature MG_HVBAT_CMU05_MAXTEMP
- Request
22 B0 21 - Service 22
DID B021 - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 05 max temperature MG_HVBAT_CMU05_MAXTEMP_V2
- Request
22 B0 21 - Service 22
DID B021 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2023 to 2026.
HV battery module 05 max voltage MG_HVBAT_CMU05_MAXVOLT
- Request
22 B0 21 - Service 22
DID B021 - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 05 max voltage MG_HVBAT_CMU05_MAXVOLT_V2
- Request
22 B0 21 - Service 22
DID B021 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023 to 2026.
HV battery module 05 min temperature MG_HVBAT_CMU05_MINTEMP
- Request
22 B0 21 - Service 22
DID B021 - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 05 min temperature MG_HVBAT_CMU05_MINTEMP_V2
- Request
22 B0 21 - Service 22
DID B021 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2023 to 2026.
HV battery module 05 min voltage MG_HVBAT_CMU05_MINVOLT
- Request
22 B0 21 - Service 22
DID B021 - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 05 min voltage MG_HVBAT_CMU05_MINVOLT_V2
- Request
22 B0 21 - Service 22
DID B021 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023 to 2026.
Battery › Modules › 06
HV battery module 06 max temperature MG_HVBAT_CMU06_MAXTEMP
- Request
22 B0 29 - Service 22
DID B029 - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 06 max temperature MG_HVBAT_CMU06_MAXTEMP_V2
- Request
22 B0 29 - Service 22
DID B029 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2023 to 2026.
HV battery module 06 max voltage MG_HVBAT_CMU06_MAXVOLT
- Request
22 B0 29 - Service 22
DID B029 - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 06 max voltage MG_HVBAT_CMU06_MAXVOLT_V2
- Request
22 B0 29 - Service 22
DID B029 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023 to 2026.
HV battery module 06 min temperature MG_HVBAT_CMU06_MINTEMP
- Request
22 B0 29 - Service 22
DID B029 - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 06 min temperature MG_HVBAT_CMU06_MINTEMP_V2
- Request
22 B0 29 - Service 22
DID B029 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2023 to 2026.
HV battery module 06 min voltage MG_HVBAT_CMU06_MINVOLT
- Request
22 B0 29 - Service 22
DID B029 - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 06 min voltage MG_HVBAT_CMU06_MINVOLT_V2
- Request
22 B0 29 - Service 22
DID B029 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023 to 2026.
Battery › Modules › 07
HV battery module 07 max temperature MG_HVBAT_CMU07_MAXTEMP
- Request
22 B0 A3 - Service 22
DID B0A3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 07 max temperature MG_HVBAT_CMU07_MAXTEMP_V2
- Request
22 B0 A3 - Service 22
DID B0A3 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2023 to 2026.
HV battery module 07 max voltage MG_HVBAT_CMU07_MAXVOLT
- Request
22 B0 A3 - Service 22
DID B0A3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 07 max voltage MG_HVBAT_CMU07_MAXVOLT_V2
- Request
22 B0 A3 - Service 22
DID B0A3 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023 to 2026.
HV battery module 07 min temperature MG_HVBAT_CMU07_MINTEMP
- Request
22 B0 A3 - Service 22
DID B0A3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 07 min temperature MG_HVBAT_CMU07_MINTEMP_V2
- Request
22 B0 A3 - Service 22
DID B0A3 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2023 to 2026.
HV battery module 07 min voltage MG_HVBAT_CMU07_MINVOLT
- Request
22 B0 A3 - Service 22
DID B0A3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 07 min voltage MG_HVBAT_CMU07_MINVOLT_V2
- Request
22 B0 A3 - Service 22
DID B0A3 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023 to 2026.
Battery › Modules › 08
HV battery module 08 max temperature MG_HVBAT_CMU08_MAXTEMP
- Request
22 B0 AB - Service 22
DID B0AB - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 08 max temperature MG_HVBAT_CMU08_MAXTEMP_V2
- Request
22 B0 AB - Service 22
DID B0AB - Module
7E5 → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2023 to 2026.
HV battery module 08 max voltage MG_HVBAT_CMU08_MAXVOLT
- Request
22 B0 AB - Service 22
DID B0AB - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 08 max voltage MG_HVBAT_CMU08_MAXVOLT_V2
- Request
22 B0 AB - Service 22
DID B0AB - Module
7E5 → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023 to 2026.
HV battery module 08 min temperature MG_HVBAT_CMU08_MINTEMP
- Request
22 B0 AB - Service 22
DID B0AB - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 08 min temperature MG_HVBAT_CMU08_MINTEMP_V2
- Request
22 B0 AB - Service 22
DID B0AB - Module
7E5 → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2023 to 2026.
HV battery module 08 min voltage MG_HVBAT_CMU08_MINVOLT
- Request
22 B0 AB - Service 22
DID B0AB - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 08 min voltage MG_HVBAT_CMU08_MINVOLT_V2
- Request
22 B0 AB - Service 22
DID B0AB - Module
7E5 → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023 to 2026.
Battery › Modules › 09
HV battery module 09 max temperature MG_HVBAT_CMU09_MAXTEMP
- Request
22 B0 B3 - Service 22
DID B0B3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 09 max temperature MG_HVBAT_CMU09_MAXTEMP_V2
- Request
22 B0 B3 - Service 22
DID B0B3 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2023 to 2026.
HV battery module 09 max voltage MG_HVBAT_CMU09_MAXVOLT
- Request
22 B0 B3 - Service 22
DID B0B3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 09 max voltage MG_HVBAT_CMU09_MAXVOLT_V2
- Request
22 B0 B3 - Service 22
DID B0B3 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023 to 2026.
HV battery module 09 min temperature MG_HVBAT_CMU09_MINTEMP
- Request
22 B0 B3 - Service 22
DID B0B3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 09 min temperature MG_HVBAT_CMU09_MINTEMP_V2
- Request
22 B0 B3 - Service 22
DID B0B3 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2023 to 2026.
HV battery module 09 min voltage MG_HVBAT_CMU09_MINVOLT
- Request
22 B0 B3 - Service 22
DID B0B3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 09 min voltage MG_HVBAT_CMU09_MINVOLT_V2
- Request
22 B0 B3 - Service 22
DID B0B3 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023 to 2026.
Battery › Modules › 10
HV battery module 10 max temperature MG_HVBAT_CMU10_MAXTEMP
- Request
22 B0 BB - Service 22
DID B0BB - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 10 max temperature MG_HVBAT_CMU10_MAXTEMP_V2
- Request
22 B0 BB - Service 22
DID B0BB - Module
7E5 → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2023 to 2026.
HV battery module 10 max voltage MG_HVBAT_CMU10_MAXVOLT
- Request
22 B0 BB - Service 22
DID B0BB - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 10 max voltage MG_HVBAT_CMU10_MAXVOLT_V2
- Request
22 B0 BB - Service 22
DID B0BB - Module
7E5 → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023 to 2026.
HV battery module 10 min temperature MG_HVBAT_CMU10_MINTEMP
- Request
22 B0 BB - Service 22
DID B0BB - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 10 min temperature MG_HVBAT_CMU10_MINTEMP_V2
- Request
22 B0 BB - Service 22
DID B0BB - Module
7E5 → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2023 to 2026.
HV battery module 10 min voltage MG_HVBAT_CMU10_MINVOLT
- Request
22 B0 BB - Service 22
DID B0BB - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 10 min voltage MG_HVBAT_CMU10_MINVOLT_V2
- Request
22 B0 BB - Service 22
DID B0BB - Module
7E5 → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023 to 2026.
Battery › Modules › 11
HV battery module 11 max temperature MG_HVBAT_CMU11_MAXTEMP
- Request
22 B0 C3 - Service 22
DID B0C3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 11 max temperature MG_HVBAT_CMU11_MAXTEMP_V2
- Request
22 B0 C3 - Service 22
DID B0C3 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2023 to 2026.
HV battery module 11 max voltage MG_HVBAT_CMU11_MAXVOLT
- Request
22 B0 C3 - Service 22
DID B0C3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 11 max voltage MG_HVBAT_CMU11_MAXVOLT_V2
- Request
22 B0 C3 - Service 22
DID B0C3 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023 to 2026.
HV battery module 11 min temperature MG_HVBAT_CMU11_MINTEMP
- Request
22 B0 C3 - Service 22
DID B0C3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 11 min temperature MG_HVBAT_CMU11_MINTEMP_V2
- Request
22 B0 C3 - Service 22
DID B0C3 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2023 to 2026.
HV battery module 11 min voltage MG_HVBAT_CMU11_MINVOLT
- Request
22 B0 C3 - Service 22
DID B0C3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 11 min voltage MG_HVBAT_CMU11_MINVOLT_V2
- Request
22 B0 C3 - Service 22
DID B0C3 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023 to 2026.
Battery › Modules › 12
HV battery module 12 max temperature MG_HVBAT_CMU12_MAXTEMP
- Request
22 B0 CB - Service 22
DID B0CB - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 12 max temperature MG_HVBAT_CMU12_MAXTEMP_V2
- Request
22 B0 CB - Service 22
DID B0CB - Module
7E5 → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2023 to 2026.
HV battery module 12 max voltage MG_HVBAT_CMU12_MAXVOLT
- Request
22 B0 CB - Service 22
DID B0CB - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 12 max voltage MG_HVBAT_CMU12_MAXVOLT_V2
- Request
22 B0 CB - Service 22
DID B0CB - Module
7E5 → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023 to 2026.
HV battery module 12 min temperature MG_HVBAT_CMU12_MINTEMP
- Request
22 B0 CB - Service 22
DID B0CB - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 12 min temperature MG_HVBAT_CMU12_MINTEMP_V2
- Request
22 B0 CB - Service 22
DID B0CB - Module
7E5 → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2023 to 2026.
HV battery module 12 min voltage MG_HVBAT_CMU12_MINVOLT
- Request
22 B0 CB - Service 22
DID B0CB - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 12 min voltage MG_HVBAT_CMU12_MINVOLT_V2
- Request
22 B0 CB - Service 22
DID B0CB - Module
7E5 → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023 to 2026.
Battery › Modules › 13
HV battery module 13 max temperature MG_HVBAT_CMU13_MAXTEMP
- Request
22 B0 DB - Service 22
DID B0DB - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 13 max temperature MG_HVBAT_CMU13_MAXTEMP_V2
- Request
22 B0 DB - Service 22
DID B0DB - Module
7E5 → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2023 to 2026.
HV battery module 13 max voltage MG_HVBAT_CMU13_MAXVOLT
- Request
22 B0 DB - Service 22
DID B0DB - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 13 max voltage MG_HVBAT_CMU13_MAXVOLT_V2
- Request
22 B0 DB - Service 22
DID B0DB - Module
7E5 → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023 to 2026.
HV battery module 13 min temperature MG_HVBAT_CMU13_MINTEMP
- Request
22 B0 DB - Service 22
DID B0DB - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 13 min temperature MG_HVBAT_CMU13_MINTEMP_V2
- Request
22 B0 DB - Service 22
DID B0DB - Module
7E5 → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2023 to 2026.
HV battery module 13 min voltage MG_HVBAT_CMU13_MINVOLT
- Request
22 B0 DB - Service 22
DID B0DB - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 13 min voltage MG_HVBAT_CMU13_MINVOLT_V2
- Request
22 B0 DB - Service 22
DID B0DB - Module
7E5 → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023 to 2026.
Battery › Modules › 14
HV battery module 14 max temperature MG_HVBAT_CMU14_MAXTEMP
- Request
22 B0 DC - Service 22
DID B0DC - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 14 max temperature MG_HVBAT_CMU14_MAXTEMP_V2
- Request
22 B0 DC - Service 22
DID B0DC - Module
7E5 → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2023 to 2026.
HV battery module 14 max voltage MG_HVBAT_CMU14_MAXVOLT
- Request
22 B0 DC - Service 22
DID B0DC - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 14 max voltage MG_HVBAT_CMU14_MAXVOLT_V2
- Request
22 B0 DC - Service 22
DID B0DC - Module
7E5 → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023 to 2026.
HV battery module 14 min temperature MG_HVBAT_CMU14_MINTEMP
- Request
22 B0 DC - Service 22
DID B0DC - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 14 min temperature MG_HVBAT_CMU14_MINTEMP_V2
- Request
22 B0 DC - Service 22
DID B0DC - Module
7E5 → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2023 to 2026.
HV battery module 14 min voltage MG_HVBAT_CMU14_MINVOLT
- Request
22 B0 DC - Service 22
DID B0DC - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 14 min voltage MG_HVBAT_CMU14_MINVOLT_V2
- Request
22 B0 DC - Service 22
DID B0DC - Module
7E5 → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023 to 2026.
Battery › Modules › 15
HV battery module 15 max temperature MG_HVBAT_CMU15_MAXTEMP
- Request
22 B0 DD - Service 22
DID B0DD - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 15 max temperature MG_HVBAT_CMU15_MAXTEMP_V2
- Request
22 B0 DD - Service 22
DID B0DD - Module
7E5 → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2023 to 2026.
HV battery module 15 max voltage MG_HVBAT_CMU15_MAXVOLT
- Request
22 B0 DD - Service 22
DID B0DD - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 15 max voltage MG_HVBAT_CMU15_MAXVOLT_V2
- Request
22 B0 DD - Service 22
DID B0DD - Module
7E5 → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023 to 2026.
HV battery module 15 min temperature MG_HVBAT_CMU15_MINTEMP
- Request
22 B0 DD - Service 22
DID B0DD - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 15 min temperature MG_HVBAT_CMU15_MINTEMP_V2
- Request
22 B0 DD - Service 22
DID B0DD - Module
7E5 → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2023 to 2026.
HV battery module 15 min voltage MG_HVBAT_CMU15_MINVOLT
- Request
22 B0 DD - Service 22
DID B0DD - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 15 min voltage MG_HVBAT_CMU15_MINVOLT_V2
- Request
22 B0 DD - Service 22
DID B0DD - Module
7E5 → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023 to 2026.
Battery › Modules › 16
HV battery module 16 max temperature MG_HVBAT_CMU16_MAXTEMP
- Request
22 B0 DE - Service 22
DID B0DE - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 16 max temperature MG_HVBAT_CMU16_MAXTEMP_V2
- Request
22 B0 DE - Service 22
DID B0DE - Module
7E5 → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2023 to 2026.
HV battery module 16 max voltage MG_HVBAT_CMU16_MAXVOLT
- Request
22 B0 DE - Service 22
DID B0DE - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 16 max voltage MG_HVBAT_CMU16_MAXVOLT_V2
- Request
22 B0 DE - Service 22
DID B0DE - Module
7E5 → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023 to 2026.
HV battery module 16 min temperature MG_HVBAT_CMU16_MINTEMP
- Request
22 B0 DE - Service 22
DID B0DE - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 16 min temperature MG_HVBAT_CMU16_MINTEMP_V2
- Request
22 B0 DE - Service 22
DID B0DE - Module
7E5 → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2023 to 2026.
HV battery module 16 min voltage MG_HVBAT_CMU16_MINVOLT
- Request
22 B0 DE - Service 22
DID B0DE - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 16 min voltage MG_HVBAT_CMU16_MINVOLT_V2
- Request
22 B0 DE - Service 22
DID B0DE - Module
7E5 → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023 to 2026.
Battery › Modules › 17
HV battery module 17 max temperature MG_HVBAT_CMU17_MAXTEMP
- Request
22 B1 0E - Service 22
DID B10E - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 17 max temperature MG_HVBAT_CMU17_MAXTEMP_V2
- Request
22 B1 0E - Service 22
DID B10E - Module
7E5 → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2023 to 2026.
HV battery module 17 max voltage MG_HVBAT_CMU17_MAXVOLT
- Request
22 B1 0E - Service 22
DID B10E - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 17 max voltage MG_HVBAT_CMU17_MAXVOLT_V2
- Request
22 B1 0E - Service 22
DID B10E - Module
7E5 → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023 to 2026.
HV battery module 17 min temperature MG_HVBAT_CMU17_MINTEMP
- Request
22 B1 0E - Service 22
DID B10E - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 17 min temperature MG_HVBAT_CMU17_MINTEMP_V2
- Request
22 B1 0E - Service 22
DID B10E - Module
7E5 → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2023 to 2026.
HV battery module 17 min voltage MG_HVBAT_CMU17_MINVOLT
- Request
22 B1 0E - Service 22
DID B10E - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 17 min voltage MG_HVBAT_CMU17_MINVOLT_V2
- Request
22 B1 0E - Service 22
DID B10E - Module
7E5 → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023 to 2026.
Battery › Modules › 18
HV battery module 18 max temperature MG_HVBAT_CMU18_MAXTEMP
- Request
22 B1 0F - Service 22
DID B10F - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 18 max temperature MG_HVBAT_CMU18_MAXTEMP_V2
- Request
22 B1 0F - Service 22
DID B10F - Module
7E5 → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2023 to 2026.
HV battery module 18 max voltage MG_HVBAT_CMU18_MAXVOLT
- Request
22 B1 0F - Service 22
DID B10F - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 18 max voltage MG_HVBAT_CMU18_MAXVOLT_V2
- Request
22 B1 0F - Service 22
DID B10F - Module
7E5 → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023 to 2026.
HV battery module 18 min temperature MG_HVBAT_CMU18_MINTEMP
- Request
22 B1 0F - Service 22
DID B10F - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 18 min temperature MG_HVBAT_CMU18_MINTEMP_V2
- Request
22 B1 0F - Service 22
DID B10F - Module
7E5 → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2023 to 2026.
HV battery module 18 min voltage MG_HVBAT_CMU18_MINVOLT
- Request
22 B1 0F - Service 22
DID B10F - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 18 min voltage MG_HVBAT_CMU18_MINVOLT_V2
- Request
22 B1 0F - Service 22
DID B10F - Module
7E5 → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023 to 2026.
Battery › Modules › 19
HV battery module 19 max temperature MG_HVBAT_CMU19_MAXTEMP
- Request
22 B1 10 - Service 22
DID B110 - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 19 max temperature MG_HVBAT_CMU19_MAXTEMP_V2
- Request
22 B1 10 - Service 22
DID B110 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2023 to 2026.
HV battery module 19 max voltage MG_HVBAT_CMU19_MAXVOLT
- Request
22 B1 10 - Service 22
DID B110 - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 19 max voltage MG_HVBAT_CMU19_MAXVOLT_V2
- Request
22 B1 10 - Service 22
DID B110 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023 to 2026.
HV battery module 19 min temperature MG_HVBAT_CMU19_MINTEMP
- Request
22 B1 10 - Service 22
DID B110 - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 19 min temperature MG_HVBAT_CMU19_MINTEMP_V2
- Request
22 B1 10 - Service 22
DID B110 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2023 to 2026.
HV battery module 19 min voltage MG_HVBAT_CMU19_MINVOLT
- Request
22 B1 10 - Service 22
DID B110 - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 19 min voltage MG_HVBAT_CMU19_MINVOLT_V2
- Request
22 B1 10 - Service 22
DID B110 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023 to 2026.
Battery › Modules › 20
HV battery module 20 max temperature MG_HVBAT_CMU20_MAXTEMP
- Request
22 B1 11 - Service 22
DID B111 - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 20 max temperature MG_HVBAT_CMU20_MAXTEMP_V2
- Request
22 B1 11 - Service 22
DID B111 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2023 to 2026.
HV battery module 20 max voltage MG_HVBAT_CMU20_MAXVOLT
- Request
22 B1 11 - Service 22
DID B111 - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 20 max voltage MG_HVBAT_CMU20_MAXVOLT_V2
- Request
22 B1 11 - Service 22
DID B111 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023 to 2026.
HV battery module 20 min temperature MG_HVBAT_CMU20_MINTEMP
- Request
22 B1 11 - Service 22
DID B111 - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 20 min temperature MG_HVBAT_CMU20_MINTEMP_V2
- Request
22 B1 11 - Service 22
DID B111 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2023 to 2026.
HV battery module 20 min voltage MG_HVBAT_CMU20_MINVOLT
- Request
22 B1 11 - Service 22
DID B111 - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 20 min voltage MG_HVBAT_CMU20_MINVOLT_V2
- Request
22 B1 11 - Service 22
DID B111 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023 to 2026.
Battery › Modules › 21
HV battery module 21 max temperature MG_HVBAT_CMU21_MAXTEMP
- Request
22 B1 12 - Service 22
DID B112 - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 21 max temperature MG_HVBAT_CMU21_MAXTEMP_V2
- Request
22 B1 12 - Service 22
DID B112 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2023 to 2026.
HV battery module 21 max voltage MG_HVBAT_CMU21_MAXVOLT
- Request
22 B1 12 - Service 22
DID B112 - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 21 max voltage MG_HVBAT_CMU21_MAXVOLT_V2
- Request
22 B1 12 - Service 22
DID B112 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023 to 2026.
HV battery module 21 min temperature MG_HVBAT_CMU21_MINTEMP
- Request
22 B1 12 - Service 22
DID B112 - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 21 min temperature MG_HVBAT_CMU21_MINTEMP_V2
- Request
22 B1 12 - Service 22
DID B112 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2023 to 2026.
HV battery module 21 min voltage MG_HVBAT_CMU21_MINVOLT
- Request
22 B1 12 - Service 22
DID B112 - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 21 min voltage MG_HVBAT_CMU21_MINVOLT_V2
- Request
22 B1 12 - Service 22
DID B112 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023 to 2026.
Battery › Modules › 22
HV battery module 22 max temperature MG_HVBAT_CMU22_MAXTEMP
- Request
22 B1 13 - Service 22
DID B113 - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 22 max temperature MG_HVBAT_CMU22_MAXTEMP_V2
- Request
22 B1 13 - Service 22
DID B113 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2023 to 2026.
HV battery module 22 max voltage MG_HVBAT_CMU22_MAXVOLT
- Request
22 B1 13 - Service 22
DID B113 - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 22 max voltage MG_HVBAT_CMU22_MAXVOLT_V2
- Request
22 B1 13 - Service 22
DID B113 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023 to 2026.
HV battery module 22 min temperature MG_HVBAT_CMU22_MINTEMP
- Request
22 B1 13 - Service 22
DID B113 - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 22 min temperature MG_HVBAT_CMU22_MINTEMP_V2
- Request
22 B1 13 - Service 22
DID B113 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2023 to 2026.
HV battery module 22 min voltage MG_HVBAT_CMU22_MINVOLT
- Request
22 B1 13 - Service 22
DID B113 - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 22 min voltage MG_HVBAT_CMU22_MINVOLT_V2
- Request
22 B1 13 - Service 22
DID B113 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023 to 2026.
Battery › Modules › 23
HV battery module 23 max temperature MG_HVBAT_CMU23_MAXTEMP
- Request
22 B1 14 - Service 22
DID B114 - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 23 max temperature MG_HVBAT_CMU23_MAXTEMP_V2
- Request
22 B1 14 - Service 22
DID B114 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2023 to 2026.
HV battery module 23 max voltage MG_HVBAT_CMU23_MAXVOLT
- Request
22 B1 14 - Service 22
DID B114 - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 23 max voltage MG_HVBAT_CMU23_MAXVOLT_V2
- Request
22 B1 14 - Service 22
DID B114 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023 to 2026.
HV battery module 23 min temperature MG_HVBAT_CMU23_MINTEMP
- Request
22 B1 14 - Service 22
DID B114 - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 23 min temperature MG_HVBAT_CMU23_MINTEMP_V2
- Request
22 B1 14 - Service 22
DID B114 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2023 to 2026.
HV battery module 23 min voltage MG_HVBAT_CMU23_MINVOLT
- Request
22 B1 14 - Service 22
DID B114 - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 23 min voltage MG_HVBAT_CMU23_MINVOLT_V2
- Request
22 B1 14 - Service 22
DID B114 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023 to 2026.
Battery › Modules › 24
HV battery module 24 max temperature MG_HVBAT_CMU24_MAXTEMP
- Request
22 B1 15 - Service 22
DID B115 - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 24 max temperature MG_HVBAT_CMU24_MAXTEMP_V2
- Request
22 B1 15 - Service 22
DID B115 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2023 to 2026.
HV battery module 24 max voltage MG_HVBAT_CMU24_MAXVOLT
- Request
22 B1 15 - Service 22
DID B115 - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 24 max voltage MG_HVBAT_CMU24_MAXVOLT_V2
- Request
22 B1 15 - Service 22
DID B115 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023 to 2026.
HV battery module 24 min temperature MG_HVBAT_CMU24_MINTEMP
- Request
22 B1 15 - Service 22
DID B115 - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 24 min temperature MG_HVBAT_CMU24_MINTEMP_V2
- Request
22 B1 15 - Service 22
DID B115 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2023 to 2026.
HV battery module 24 min voltage MG_HVBAT_CMU24_MINVOLT
- Request
22 B1 15 - Service 22
DID B115 - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023, 2025 to 2026. Not supported for 2024.
HV battery module 24 min voltage MG_HVBAT_CMU24_MINVOLT_V2
- Request
22 B1 15 - Service 22
DID B115 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2023 to 2026.