MG Comet

Electrical parameters

The MG Comet has 9 electrical parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

12V supply voltage MG_12V_V

Pelican can show this parameter as the starter battery voltage.

  • Request22 01 12
  • Service 22DID 0112
  • Module7E3 → 7EB
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 V
Unit
V

In testing for 2023 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

12V supply voltage MG_12V_V

Pelican can show this parameter as the starter battery voltage.

  • Request22 01 12
  • Service 22DID 0112
  • Module7E3 → 7EB
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 V
Unit
V

In testing for 2023 to 2026.

DC/DC converter input current MG_DCDC_IN_A

  • Request22 B5 81
  • Service 22DID B581
  • Module7E3 → 7EB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 3276.7)
Range
-3276.7 to 3276.8 A
Unit
A

In testing for 2023 to 2026.

DC/DC converter input voltage MG_DCDC_IN_V

  • Request22 B5 82
  • Service 22DID B582
  • Module7E3 → 7EB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553.5 V
Unit
V

In testing for 2023 to 2026.

DC/DC converter load MG_DCDC_LOAD

  • Request22 B0 25
  • Service 22DID B025
  • Module785 → 78D
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383.75 %
Unit
%

In testing for 2023 to 2026.

DC/DC converter mode MG_DCDC_MODE

  • Request22 B5 80
  • Service 22DID B580
  • Module7E3 → 7EB
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

DC/DC converter output current MG_DCDC_OUT_A

  • Request22 B5 83
  • Service 22DID B583
  • Module7E3 → 7EB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553.5 A
Unit
A

In testing for 2023 to 2026.

DC/DC converter output voltage MG_DCDC_OUT_V

  • Request22 B5 84
  • Service 22DID B584
  • Module7E3 → 7EB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553.5 V
Unit
V

In testing for 2023 to 2026.

DC/DC converter temperature MG_DCDC_T

  • Request22 B0 26
  • Service 22DID B026
  • Module785 → 78D
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val − 40)
Range
-40 to 65495 °C
Unit
°C

In testing for 2023 to 2026.

DC/DC converter temperature, vehicle control unit MG_DCDC_T_VCU

  • Request22 B5 87
  • Service 22DID B587
  • Module7E3 → 7EB
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2023 to 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.