Nissan Frontier

Climate parameters

The Nissan Frontier has 12 climate parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Engine coolant temperature FRONTIER_ECTConfirmed

Pelican can show this parameter as the engine coolant temperature.

  • Request22 F4 67
  • Service 22DID F467
  • Module744 → 764
  • Every5 s

Example reply from a 2026 Nissan Frontier.

Bits 0 to 7 of the reply, 8 bits.

0x48 = 72 → (72 − 40) = 32 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2022 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Air conditioning compressor speed FRONTIER_AC_COMP_RPM

  • Request21 10
  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bits 168 to 183 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2022 to 2024, 2026. Not supported for 2025.

Air conditioning on FRONTIER_HVAC_AC_ON

  • Request21 10
  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bit 80 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2022 to 2024, 2026. Not supported for 2025.

Air conditioning status code FRONTIER_AC_STATUSConfirmed

  • Request22 40 07
  • Service 22DID 4007
  • Module744 → 764
  • Every5 s

Example reply from a 2026 Nissan Frontier.

Bits 0 to 7 of the reply, 8 bits.

0x0B = 11 → 11

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2022 to 2026.

Ambient air temperature AATSAE J1979Confirmed

  • Request01 46
  • Service 01PID 46
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023, 2025.

Ambient air temperature FRONTIER_AATConfirmed

  • Request22 40 08
  • Service 22DID 4008
  • Module744 → 764
  • Every5 s

Example reply from a 2026 Nissan Frontier.

Bits 0 to 7 of the reply, 8 bits.

0x23 = 35 → (35 − 40) = -5 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2022 to 2026.

Ambient air temperature, climate module FRONTIER_HVAC_AAT

  • Request21 10
  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2022 to 2024, 2026. Not supported for 2025.

Blower on FRONTIER_HVAC_FAN_ON

  • Request21 10
  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bit 88 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2022 to 2024, 2026. Not supported for 2025.

Blower voltage FRONTIER_HVAC_BLOWER_V

  • Request21 10
  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bits 89 to 95 of the reply, 7 bits.

Formula
val
Range
0 to 127 V
Unit
V

In testing for 2022 to 2024, 2026. Not supported for 2025.

Cabin temperature FRONTIER_HVAC_CABIN_T

  • Request21 10
  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2022 to 2024, 2026. Not supported for 2025.

Engine coolant temperature FRONTIER_ECTConfirmed

Pelican can show this parameter as the engine coolant temperature.

  • Request22 F4 67
  • Service 22DID F467
  • Module744 → 764
  • Every5 s

Example reply from a 2026 Nissan Frontier.

Bits 0 to 7 of the reply, 8 bits.

0x48 = 72 → (72 − 40) = 32 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2022 to 2026.

Evaporator temperature FRONTIER_HVAC_EVAP_T

  • Request21 10
  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2022 to 2024, 2026. Not supported for 2025.

Sun load FRONTIER_HVAC_SUNLOAD

  • Request21 10
  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2022 to 2024, 2026. Not supported for 2025.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.