Nissan X-Trail

Fuel parameters

The Nissan X-Trail has 6 fuel parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Engine fuel rate FUEL_RATEConfirmed

Measured in units per hour

Pelican can show this parameter as the fuel rate.

  • Request01 5E
  • Service 01PID 5E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 20)
Range
0 to 3212.75 L/h
Unit
L/h

Confirmed for 2023. Supported for 2024.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Engine fuel rate FUEL_RATESAE J1979Confirmed

Measured in units per hour

Pelican can show this parameter as the fuel rate.

  • Request01 5E
  • Service 01PID 5E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 20)
Range
0 to 3212.75 L/h
Unit
L/h

Confirmed for 2023. Supported for 2024.

Fuel level input XTRAIL_FLI_INPUT

  • Request22 11 14
  • Service 22DID 1114
  • ModuleDA18 → 18
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 25)
Range
0 to 10.2 V
Unit
V

In testing for 2021 to 2026.

Fuel pump flow XTRAIL_FUEL_PMP_FLOW

  • Request21 AD
  • Service 21PID AD
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
(val ÷ 8)
Range
0 to 31.87 g/s
Unit
g/s

In testing for 2001 to 2017, 2019 to 2026. Not supported for 2018.

Fuel rail temperature XTRAIL_FUEL_RAIL_T

  • Request21 AD
  • Service 21PID AD
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val × 3 ÷ 4 − 48)
Range
-48 to 143 °C
Unit
°C

In testing for 2001 to 2017, 2019 to 2026. Not supported for 2018.

Fuel tank temperature XTRAIL_FUEL_TANK_T

  • Request21 AD
  • Service 21PID AD
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val × 3 ÷ 4 − 48)
Range
-48 to 143 °C
Unit
°C

In testing for 2001 to 2017, 2019 to 2026. Not supported for 2018.

Fuel temperature XTRAIL_FUEL_T

  • Request22 11 11
  • Service 22DID 1111
  • ModuleDA18 → 18
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2021 to 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.