smart fortwo

Connectable parameters

The smart fortwo has 9 Connectables, parameters that Pelican can monitor automatically.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

HV battery state of charge FORTWO_EQA_HV_SOC

Pelican can show this parameter as the state of charge.

  • Request22 60 50
  • Service 22DID 6050
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

In testing for 1998 to 2024.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

State of charge

HV battery state of charge FORTWO_EQA_HV_SOC

Pelican can show this parameter as the state of charge.

  • Request22 60 50
  • Service 22DID 6050
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

In testing for 1998 to 2024.

State of charge FORTWO_SOC

Pelican can show this parameter as the state of charge.

  • Request21 08
  • Service 21PID 08
  • Module79B → 7BB
  • Every10 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val ÷ 16)
Range
0 to 4095.9375 %
Unit
%

In testing for 1998 to 2024.

State of health

State of health FORTWO_SOH

Pelican can show this parameter as the state of health.

  • Request21 61
  • Service 21PID 61
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127.5 %
Unit
%

In testing for 1998 to 2024.

Plug state

Charging plug detected FORTWO_PLUG

Pelican can show this parameter as the plug state.

  • Request22 33 9D
  • Service 22DID 339D
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 4 to 7 of the reply, 4 bits.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 1998 to 2024.

Electric range

HV battery remaining distance FORTWO_EQA_HV_RANGE

Pelican can show this parameter as the electric range.

  • Request22 65 02
  • Service 22DID 6502
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000 km
Unit
km

In testing for 1998 to 2024.

Starter battery voltage

12V system voltage, hd FORTWO_EQA_AUX_V_HD

Pelican can show this parameter as the starter battery voltage.

  • Request22 02 01
  • Service 22DID 0201
  • Module624 → 5A4
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 1000 ÷ 10000)
Range
0 to 100 V
Unit
V

In testing for 1998 to 2024.

Auxiliary battery voltage FORTWO_EQA_AUX_V

Pelican can show this parameter as the starter battery voltage.

  • Request22 20 05
  • Service 22DID 2005
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 25.9 ÷ 255)
Range
0 to 25.9 V
Unit
V

In testing for 1998 to 2024.

Traction battery current

HV battery current FORTWO_HV_A

Pelican can show this parameter as the traction battery current.

  • Request21 07
  • Service 21PID 07
  • Module79B → 7BB
  • Every5 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The value is signed.

Formula
(val × -1 ÷ 32)
Range
-1023.9687 to 1024 A
Unit
A

In testing for 1998 to 2024.

Traction battery voltage

HV battery voltage FORTWO_HV_V

Pelican can show this parameter as the traction battery voltage.

  • Request21 07
  • Service 21PID 07
  • Module79B → 7BB
  • Every5 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val ÷ 64)
Range
0 to 1023.9843 V
Unit
V

In testing for 1998 to 2024.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.