Electrical parameters
The smart fortwo has 8 electrical parameters.
● Confirmed◆ In testing○ Supported× Not supported
12V supply voltage, battery controller FORTWO_12V_V_BMS
- Request
21 07 - Service 21
PID 07 - Module
79B → 7BB - Every
5 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
(val ÷ 8)- Range
- 0 to 31.875 V
- Unit
- V
In testing for 1998 to 2024.
DC/DC activation request FORTWO_DCDC_REQ
- Request
22 30 22 - Service 22
DID 3022 - Module
7E4 → 7EC - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1998 to 2024.
DC/DC load FORTWO_DCDC_LOAD
- Request
22 34 95 - Service 22
DID 3495 - Module
7E4 → 7EC - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2.56)- Range
- 0 to 99.21875 %
- Unit
- %
In testing for 1998 to 2024.
DC/DC output current FORTWO_DCDC_A
- Request
22 30 25 - Service 22
DID 3025 - Module
7E4 → 7EC - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 A
- Unit
- A
In testing for 1998 to 2024.
DC/DC output power FORTWO_DCDC_P
- Request
22 34 94 - Service 22
DID 3494 - Module
7E4 → 7EC - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 W
- Unit
- W
In testing for 1998 to 2024.
DC/DC output voltage FORTWO_DCDC_V
- Request
22 30 24 - Service 22
DID 3024 - Module
7E4 → 7EC - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10 + 4)- Range
- 4 to 29.5 V
- Unit
- V
In testing for 1998 to 2024.
DC/DC voltage request FORTWO_DCDC_V_REQ
- Request
22 30 23 - Service 22
DID 3023 - Module
7E4 → 7EC - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 20 + 12)- Range
- 12 to 24.75 V
- Unit
- V
In testing for 1998 to 2024.
Power distribution 12V voltage FORTWO_USM_V
- Request
22 33 01 - Service 22
DID 3301 - Module
7E4 → 7EC - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 0.06 + 6)- Range
- 6 to 21.2999 V
- Unit
- V
In testing for 1998 to 2024.