smart fortwo

Engine parameters

The smart fortwo has 7 engine parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Coolant pump current FORTWO_ED_PUMP_A

  • Request22 23 09
  • Service 22DID 2309
  • Module7E5 → 7ED
  • Every60 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val ÷ 5)
Range
0 to 51 A
Unit
A

In testing for 1998 to 2024.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Coolant pump current FORTWO_ED_PUMP_A

  • Request22 23 09
  • Service 22DID 2309
  • Module7E5 → 7ED
  • Every60 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val ÷ 5)
Range
0 to 51 A
Unit
A

In testing for 1998 to 2024.

Coolant pump speed FORTWO_ED_PUMP_DUTY

  • Request22 D0 32
  • Service 22DID D032
  • Module7E5 → 7ED
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2.55)
Range
0 to 100 %
Unit
%

In testing for 1998 to 2024.

Coolant pump temperature FORTWO_ED_PUMP_T

  • Request22 23 0A
  • Service 22DID 230A
  • Module7E5 → 7ED
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 1998 to 2024.

Coolant pump voltage FORTWO_ED_PUMP_V

  • Request22 23 08
  • Service 22DID 2308
  • Module7E5 → 7ED
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 V
Unit
V

In testing for 1998 to 2024.

Coolant temperature FORTWO_ED_COOLANT_T

  • Request22 20 47
  • Service 22DID 2047
  • Module7E5 → 7ED
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 8)
Range
0 to 8191.875 °C
Unit
°C

In testing for 1998 to 2024.

Cooling fan speed FORTWO_ED_FAN_DUTY

  • Request22 D0 41
  • Service 22DID D041
  • Module7E5 → 7ED
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2.55)
Range
0 to 100 %
Unit
%

In testing for 1998 to 2024.

Distance to next service FORTWO_EQA_SERVICE_DIST

  • Request22 65 04
  • Service 22DID 6504
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 1998 to 2024.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.