Toyota Corolla Hybrid

Connectable parameters

The Toyota Corolla Hybrid has 40 Connectables, parameters that Pelican can monitor automatically.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

State of charge COROLLAHYBRID_SOCConfirmed

Pelican can show this parameter as the state of charge.

  • Request22 1F 5B
  • Service 22DID 1F5B
  • Module7D2 → 7DA
  • Every1 s
  • Testing for 2022, 2026

Example reply from a 2025 Toyota Corolla Hybrid.

Bits 0 to 7 of the reply, 8 bits.

0x75 = 117 → (117 × 100 ÷ 255) = 45.882353 %

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2019 to 2021, 2023 to 2025. In testing for 2022, 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

State of charge

State of charge COROLLAHYBRID_SOCConfirmed

Pelican can show this parameter as the state of charge.

  • Request22 1F 5B
  • Service 22DID 1F5B
  • Module7D2 → 7DA
  • Every1 s
  • Testing for 2022, 2026

Example reply from a 2025 Toyota Corolla Hybrid.

Bits 0 to 7 of the reply, 8 bits.

0x75 = 117 → (117 × 100 ÷ 255) = 45.882353 %

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2019 to 2021, 2023 to 2025. In testing for 2022, 2026.

Fuel tank level

Fuel level, volume COROLLAHYBRID_FLI_VOL

Pelican can show this parameter as the fuel tank level.

  • Request21 29
  • Service 21PID 29
  • Module7C0 → 7C8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 500 ÷ 3785)
Range
0 to 21 gal
Unit
gal

In testing for 2019, 2021 to 2026. Not supported for 2020.

Fuel remaining COROLLAHYBRID_FLVConfirmed

Pelican can show this parameter as the fuel tank level.

  • Request22 10 22
  • Service 22DID 1022
  • Module7C0 → 7C8
  • Every1 s
  • Testing for 2022, 2026

Example reply from a 2025 Toyota Corolla Hybrid.

Bits 0 to 15 of the reply, 16 bits.

0x064B = 1611 → (1611 ÷ 100) = 16.11 L

Formula
(val ÷ 100)
Range
0 to 655 L
Unit
L

Confirmed for 2019 to 2021, 2023 to 2025. In testing for 2022, 2026.

Speed

Speed COROLLAHYBRID_VSS_7C0

Pelican can show this parameter as the speed.

  • Request21 21
  • Service 21PID 21
  • Module7C0 → 7C8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2019, 2021 to 2026. Not supported for 2020.

Vehicle speed COROLLAHYBRID_VSSConfirmed

Current vehicle speed.

Pelican can show this parameter as the speed.

  • Request21 21
  • Service 21PID 21
  • Module7B0 → 7B8
  • Every200 ms
  • Testing for 2019, 2021 to 2026

Example reply from a 2020 Toyota Corolla Hybrid.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → (0 × 1.35) = 0 km/h

Formula
(val × 1.35)
Range
0 to 323.85 km/h
Unit
km/h

Confirmed for 2020. In testing for 2019, 2021 to 2026.

Vehicle speed COROLLAHYBRID_VSS_V2Confirmed

Pelican can show this parameter as the speed.

  • Request22 1F 0D
  • Service 22DID 1F0D
  • Module7D2 → 7DA
  • Every250 ms
  • Testing for 2019, 2021 to 2026

Example reply from a 2020 Toyota Corolla Hybrid.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0 km/h

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2020. In testing for 2019, 2021 to 2026.

Vehicle speed VSSSAE J1979Confirmed

Pelican can show this parameter as the speed.

  • Request01 0D
  • Service 01PID 0D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2020, 2022, 2026. Supported for 2019, 2021, 2023 to 2025.

Odometer

Odometer COROLLAHYBRID_ODO

Pelican can show this parameter as the odometer.

  • Request22 01 03
  • Service 22DID 0103
  • Module747 → 74F
  • Every10 s
  • Testing

Bits 8 to 31 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2019, 2021 to 2026. Not supported for 2020.

Odometer COROLLAHYBRID_ODO_V2_V2Confirmed

Pelican can show this parameter as the odometer.

  • Request22 01 03
  • Service 22DID 0103
  • Module7D2 → 7DA
  • Every10 s
  • Testing for 2019, 2021 to 2026

Example reply from a 2020 Toyota Corolla Hybrid.

Bits 8 to 31 of the reply, 24 bits.

0x011064 = 69732 → 69,732 km

Formula
val
Range
0 to 16777215 km
Unit
km

Confirmed for 2020. In testing for 2019, 2021 to 2026.

Front left tire pressure

Front left tire pressure COROLLAHYBRID_TP_FLConfirmed

Pelican can show this parameter as the front left tire pressure.

  • Request21 30
  • Service 21PID 30
  • Module750 → 758
  • Every2.5 s
  • Testing for 2019, 2021 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 58 − 0.5)
Range
0 to 3.896 bar
Unit
bar

Confirmed for 2020. In testing for 2019, 2021 to 2026.

Front left tire pressure COROLLAHYBRID_TP_2Confirmed

Pelican can show this parameter as the front left tire pressure.

  • Request22 10 05
  • Service 22DID 1005
  • Module750 → 758
  • Every5 s
  • Testing for 2019 to 2022, 2026

Example reply from a 2025 Toyota Corolla Hybrid.

Bits 24 to 31 of the reply, 8 bits.

0xA2 = 162 → (162 ÷ 4.125 − 5.6969697) = 33.575758 psi

Formula
(val ÷ 4.125 − 5.6969697)
Range
0 to 56.1212 psi
Unit
psi

Confirmed for 2023 to 2025. Not supported for 2019 to 2022, 2026.

Front right tire pressure

Front right tire pressure COROLLAHYBRID_TP_FRConfirmed

Pelican can show this parameter as the front right tire pressure.

  • Request21 30
  • Service 21PID 30
  • Module750 → 758
  • Every2.5 s
  • Testing for 2019, 2021 to 2026

Bits 8 to 15 of the reply, 8 bits.

Formula
(val ÷ 58 − 0.5)
Range
0 to 3.896 bar
Unit
bar

Confirmed for 2020. In testing for 2019, 2021 to 2026.

Front right tire pressure COROLLAHYBRID_TP_1Confirmed

Pelican can show this parameter as the front right tire pressure.

  • Request22 10 05
  • Service 22DID 1005
  • Module750 → 758
  • Every5 s
  • Testing for 2019 to 2022, 2026

Example reply from a 2025 Toyota Corolla Hybrid.

Bits 8 to 15 of the reply, 8 bits.

0xA0 = 160 → (160 ÷ 4.125 − 5.6969697) = 33.090909 psi

Formula
(val ÷ 4.125 − 5.6969697)
Range
0 to 56.1212 psi
Unit
psi

Confirmed for 2023 to 2025. Not supported for 2019 to 2022, 2026.

Rear left tire pressure

Rear left tire pressure COROLLAHYBRID_TP_RLConfirmed

Pelican can show this parameter as the rear left tire pressure.

  • Request21 30
  • Service 21PID 30
  • Module750 → 758
  • Every2.5 s
  • Testing for 2019, 2021 to 2026

Bits 16 to 23 of the reply, 8 bits.

Formula
(val ÷ 58 − 0.5)
Range
0 to 3.896 bar
Unit
bar

Confirmed for 2020. In testing for 2019, 2021 to 2026.

Rear left tire pressure COROLLAHYBRID_TP_4Confirmed

Pelican can show this parameter as the rear left tire pressure.

  • Request22 10 05
  • Service 22DID 1005
  • Module750 → 758
  • Every5 s
  • Testing for 2019 to 2022, 2026

Example reply from a 2025 Toyota Corolla Hybrid.

Bits 56 to 63 of the reply, 8 bits.

0xB1 = 177 → (177 ÷ 4.125 − 5.6969697) = 37.212121 psi

Formula
(val ÷ 4.125 − 5.6969697)
Range
0 to 56.1212 psi
Unit
psi

Confirmed for 2023 to 2025. Not supported for 2019 to 2022, 2026.

Rear right tire pressure

Rear right tire pressure COROLLAHYBRID_TP_RRConfirmed

Pelican can show this parameter as the rear right tire pressure.

  • Request21 30
  • Service 21PID 30
  • Module750 → 758
  • Every2.5 s
  • Testing for 2019, 2021 to 2026

Example reply from a 2020 Toyota Corolla Hybrid.

Bits 24 to 31 of the reply, 8 bits.

0x98 = 152 → (152 ÷ 58 − 0.5) = 2.12069 bar

Formula
(val ÷ 58 − 0.5)
Range
0 to 3.896 bar
Unit
bar

Confirmed for 2020. In testing for 2019, 2021 to 2026.

Rear right tire pressure COROLLAHYBRID_TP_3Confirmed

Pelican can show this parameter as the rear right tire pressure.

  • Request22 10 05
  • Service 22DID 1005
  • Module750 → 758
  • Every5 s
  • Testing for 2019 to 2022, 2026

Example reply from a 2025 Toyota Corolla Hybrid.

Bits 40 to 47 of the reply, 8 bits.

0xAB = 171 → (171 ÷ 4.125 − 5.6969697) = 35.757576 psi

Formula
(val ÷ 4.125 − 5.6969697)
Range
0 to 56.1212 psi
Unit
psi

Confirmed for 2023 to 2025. Not supported for 2019 to 2022, 2026.

CheckEngineLightOn

Malfunction indicator lamp MILSAE J1979Confirmed

The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.

Pelican can show this parameter as the checkEngineLightOn.

  • Request01 01
  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2022. Supported for 2019 to 2021, 2023 to 2026.

Commanded lambda

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Fuel systems that utilize conventional oxygen sensor display the inverse of the commanded open loop equivalence ratio (also known as lambda) while the fuel control system is in open loop. Will indicate 1.000 while in closed-loop fuel.

Pelican can show this parameter as the commanded lambda.

  • Request01 44
  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 2 ÷ 65535)
Range
0 to 1.99
Unit
Number

Confirmed for 2020, 2022, 2026. Supported for 2019, 2021, 2023 to 2025.

Distance since trouble codes were cleared

Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Request01 31
  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2020, 2022, 2026. Supported for 2019, 2021, 2023 to 2025.

Engine coolant temperature

Engine coolant temperature COROLLAHYBRID_ECT_7C0

Pelican can show this parameter as the engine coolant temperature.

  • Request21 23
  • Service 21PID 23
  • Module7C0 → 7C8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127.5 °C
Unit
°C

In testing for 2019, 2021 to 2026. Not supported for 2020.

Engine coolant temperature COROLLAHYBRID_ECTConfirmed

Pelican can show this parameter as the engine coolant temperature.

  • Request21 26
  • Service 21PID 26
  • Module7C4 → 7CC
  • Every5 s
  • Testing for 2019, 2021 to 2026

Example reply from a 2020 Toyota Corolla Hybrid.

Bits 0 to 7 of the reply, 8 bits.

0x95 = 149 → (149 × 89.25 ÷ 255 + 1.3) = 53.45 °C

Formula
(val × 89.25 ÷ 255 + 1.3)
Range
1.3 to 90.55 °C
Unit
°C

Confirmed for 2020. In testing for 2019, 2021 to 2026.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Request01 05
  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2020, 2022. Supported for 2019, 2021, 2023 to 2026.

Engine load

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Request01 04
  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2020, 2022. Supported for 2019, 2021, 2023 to 2026.

Front left tire temperature

Front left tire temperature COROLLAHYBRID_TT_FL

Pelican can show this parameter as the front left tire temperature.

  • Request21 16
  • Service 21PID 16
  • Module750 → 758
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2019, 2021 to 2026. Not supported for 2020.

Front right tire temperature

Front right tire temperature COROLLAHYBRID_TT_FR

Pelican can show this parameter as the front right tire temperature.

  • Request21 16
  • Service 21PID 16
  • Module750 → 758
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2019, 2021 to 2026. Not supported for 2020.

Mass air flow

Air flow rate from mass air flow sensor MAFSAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Request01 10
  • Service 01PID 10
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 g/s
Unit
g/s

Confirmed for 2020, 2022. Supported for 2019, 2021, 2023 to 2026.

O2 lambda

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_VOLTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Request01 24
  • Service 01PID 24
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32768)
Range
0 to 1.99
Unit
Number

Confirmed for 2022, 2026. Supported for 2019 to 2021, 2024 to 2025.

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Request01 34
  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32768)
Range
0 to 1.99
Unit
Number

Confirmed for 2022. Supported for 2019 to 2021, 2023 to 2026.

Rear left tire temperature

Rear left tire temperature COROLLAHYBRID_TT_RL

Pelican can show this parameter as the rear left tire temperature.

  • Request21 16
  • Service 21PID 16
  • Module750 → 758
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2019, 2021 to 2026. Not supported for 2020.

Rear right tire temperature

Rear right tire temperature COROLLAHYBRID_TT_RR

Pelican can show this parameter as the rear right tire temperature.

  • Request21 16
  • Service 21PID 16
  • Module750 → 758
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2019, 2021 to 2026. Not supported for 2020.

Short term fuel trim

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Request01 06
  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.2 %
Unit
%

Confirmed for 2020, 2022. Supported for 2019, 2021, 2023 to 2026.

Starter battery voltage

12V battery voltage COROLLAHYBRID_12V_V_V2Confirmed

Pelican can show this parameter as the starter battery voltage.

  • Request22 15 EE
  • Service 22DID 15EE
  • Module7D2 → 7DA
  • Every1 s
  • Testing for 2019, 2021 to 2026

Example reply from a 2020 Toyota Corolla Hybrid.

Bits 0 to 7 of the reply, 8 bits.

0x28 = 40 → (40 × 0.31448 + 0.0125) = 12.5917 V

Formula
(val × 0.31448 + 0.0125)
Range
0 to 80.2 V
Unit
V

Confirmed for 2020. In testing for 2019, 2021 to 2026.

B+ battery voltage COROLLAHYBRID_BATTERY_VOLTAGE_7C0Confirmed

Pelican can show this parameter as the starter battery voltage.

  • Request22 10 21
  • Service 22DID 1021
  • Module7C0 → 7C8
  • Every5 s
  • Testing for 2019, 2021 to 2026

Example reply from a 2020 Toyota Corolla Hybrid.

Bits 0 to 7 of the reply, 8 bits.

0x7C = 124 → (124 ÷ 10) = 12.4 V

Formula
(val ÷ 10)
Range
0 to 20 V
Unit
V

Confirmed for 2020. In testing for 2019, 2021 to 2026.

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Request01 42
  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65535 V
Unit
V

Confirmed for 2022. Supported for 2019 to 2021, 2023 to 2026.

StoredDTCCount

Number of DTCs stored in this ECU DTC_CNTSAE J1979Confirmed

Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.

Pelican can show this parameter as the storedDTCCount.

  • Request01 01
  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bits 1 to 7 of the reply, 7 bits.

Formula
val
Range
0 to 127
Unit
Number

Confirmed for 2022. Supported for 2019 to 2021, 2023 to 2026.

Throttle position

Absolute throttle position TPSAE J1979Confirmed

Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.

Pelican can show this parameter as the throttle position.

  • Request01 11
  • Service 01PID 11
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2022. Supported for 2019 to 2021, 2023 to 2026.

Absolute throttle position B TP_BSAE J1979Confirmed

Pelican can show this parameter as the throttle position.

  • Request01 47
  • Service 01PID 47
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2022, 2026. Supported for 2019 to 2021, 2023 to 2025.

Traction battery current

HV battery current COROLLAHYBRID_HVBAT_CConfirmed

Pelican can show this parameter as the traction battery current.

  • Request22 1F 9A
  • Service 22DID 1F9A
  • Module7D2 → 7DA
  • Every500 ms
  • Testing for 2019, 2021 to 2026

Example reply from a 2020 Toyota Corolla Hybrid.

Bits 32 to 47 of the reply, 16 bits. The value is signed.

0x0490 = 1168 → (1168 ÷ 10) = 116.8 A

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 A
Unit
A

Confirmed for 2020. In testing for 2019, 2021 to 2026.

Traction battery voltage

HV battery voltage COROLLAHYBRID_HVBAT_VConfirmed

Pelican can show this parameter as the traction battery voltage.

  • Request22 1F 9A
  • Service 22DID 1F9A
  • Module7D2 → 7DA
  • Every500 ms
  • Testing for 2019, 2021 to 2026

Example reply from a 2020 Toyota Corolla Hybrid.

Bits 16 to 31 of the reply, 16 bits.

0x2CC0 = 11456 → (11456 × 156.25 ÷ 10000) = 179 V

Formula
(val × 156.25 ÷ 10000)
Range
0 to 1023 V
Unit
V

Confirmed for 2020. In testing for 2019, 2021 to 2026.