Battery parameters
The Volkswagen e-Up has 188 battery parameters.
● Confirmed◆ In testing○ Supported× Not supported
Battery voltage EUP_BAT_V
Pelican can show this parameter as the starter battery voltage.
- Request
22 10 5A - Service 22
DID 105A - Module
7E0 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 20)- Range
- 0 to 1310700 mV
- Unit
- mV
In testing for 2013 to 2023.
Charger AC input current EUP_CHG_AC_I
- Request
22 1D A8 - Service 22
DID 1DA8 - Module
744 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 A
- Unit
- A
In testing for 2013 to 2023.
Charger AC input current setpoint EUP_CHG_AC_I_SET
- Request
22 15 D3 - Service 22
DID 15D3 - Module
744 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 A
- Unit
- A
In testing for 2013 to 2023.
Charger AC input voltage EUP_CHG_AC_V
- Request
22 1D A9 - Service 22
DID 1DA9 - Module
744 - Every
30 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 V
- Unit
- V
In testing for 2013 to 2023.
Charger DC link voltage EUP_CHG_LINK_V
- Request
22 15 DB - Service 22
DID 15DB - Module
744 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2013 to 2023.
Charger DC to DC coil temperature EUP_CHG_DCDC_COIL_T
- Request
22 15 DA - Service 22
DID 15DA - Module
744 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2013 to 2023.
Charger DC to DC gate driver voltage EUP_CHG_DCDC_GATE_V
- Request
22 15 DD - Service 22
DID 15DD - Module
744 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2013 to 2023.
Charger DC to DC power line temperature EUP_CHG_DCDC_LINE_T
- Request
22 15 EC - Service 22
DID 15EC - Module
744 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2013 to 2023.
Charger output current EUP_CHG_HV_I
- Request
22 42 37 - Service 22
DID 4237 - Module
744 - Every
250 ms - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val ÷ 4)- Range
- 0 to 63.749 A
- Unit
- A
In testing for 2013 to 2023.
Charger output current setpoint EUP_CHG_HV_I_SET
- Request
22 42 38 - Service 22
DID 4238 - Module
744 - Every
30 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val ÷ 4)- Range
- 0 to 63.749 A
- Unit
- A
In testing for 2013 to 2023.
Charger output voltage EUP_CHG_OUT_V
- Request
22 1D A7 - Service 22
DID 1DA7 - Module
744 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 V
- Unit
- V
In testing for 2013 to 2023.
Charger power factor coil temperature EUP_CHG_PFC_COIL_T
- Request
22 15 D9 - Service 22
DID 15D9 - Module
744 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2013 to 2023.
Charger power factor gate driver voltage EUP_CHG_PFC_GATE_V
- Request
22 15 DC - Service 22
DID 15DC - Module
744 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2013 to 2023.
Charger power loss EUP_CHG_PWR_LOSS
- Request
22 15 E1 - Service 22
DID 15E1 - Module
744 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20)- Range
- 0 to 5100 W
- Unit
- W
In testing for 2013 to 2023.
Charger temperature EUP_CHG_T
- Request
22 15 D8 - Service 22
DID 15D8 - Module
744 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2013 to 2023.
Charging efficiency EUP_CHG_EFFICIENCY
- Request
22 15 D6 - Service 22
DID 15D6 - Module
744 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10 + 75)- Range
- 0 to 100.499 %
- Unit
- %
In testing for 2013 to 2023.
DC to DC converter circuit board temperature EUP_DCDC_PCB_T
- Request
22 46 4E - Service 22
DID 464E - Module
7E6 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2013 to 2023.
DC to DC converter high-voltage side voltage EUP_DCDC_HV_V
- Request
22 15 87 - Service 22
DID 1587 - Module
7E0 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.968 V
- Unit
- V
In testing for 2013 to 2023.
DC to DC converter link voltage EUP_DCDC_LINK_V
- Request
22 3E 72 - Service 22
DID 3E72 - Module
7E6 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.968 V
- Unit
- V
In testing for 2013 to 2023.
DC to DC converter power stage temperature EUP_DCDC_PWR_T
- Request
22 46 4F - Service 22
DID 464F - Module
7E6 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2013 to 2023.
DC to DC converter regulated output voltage EUP_PE_DCDC_KL30_V
- Request
22 46 5C - Service 22
DID 465C - Module
7E6 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 512)- Range
- -64 to 63.998 V
- Unit
- V
In testing for 2013 to 2023.
DC to DC converter temperature EUP_PE_DCDC_T
- Request
22 3E B5 - Service 22
DID 3EB5 - Module
7E6 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2013 to 2023.
DC to DC converter traction current EUP_DCDC_HV_I
- Request
22 46 50 - Service 22
DID 4650 - Module
7E6 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 512)- Range
- -64 to 63.998 A
- Unit
- A
In testing for 2013 to 2023.
DC to DC converter traction voltage EUP_PE_DCDC_HV_V
- Request
22 46 5E - Service 22
DID 465E - Module
7E6 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.968 V
- Unit
- V
In testing for 2013 to 2023.
HV battery capacity EUP_HVBAT_CAP
Total possible energy in the high voltage battery
- Request
22 2A B2 - Service 22
DID 2AB2 - Module
710 → 77A - Every
86400 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 1310770)- Range
- 0 to 3276 kWh
- Unit
- kWh
In testing for 2013 to 2023.
HV battery cell 1 voltage EUP_HVBAT_CELL_1_V
- Request
22 1E 40 - Service 22
DID 1E40 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 2 voltage EUP_HVBAT_CELL_2_V
- Request
22 1E 41 - Service 22
DID 1E41 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 3 voltage EUP_HVBAT_CELL_3_V
- Request
22 1E 42 - Service 22
DID 1E42 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 4 voltage EUP_HVBAT_CELL_4_V
- Request
22 1E 43 - Service 22
DID 1E43 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 5 voltage EUP_HVBAT_CELL_5_V
- Request
22 1E 44 - Service 22
DID 1E44 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 6 voltage EUP_HVBAT_CELL_6_V
- Request
22 1E 45 - Service 22
DID 1E45 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 7 voltage EUP_HVBAT_CELL_7_V
- Request
22 1E 46 - Service 22
DID 1E46 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 8 voltage EUP_HVBAT_CELL_8_V
- Request
22 1E 47 - Service 22
DID 1E47 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 9 voltage EUP_HVBAT_CELL_9_V
- Request
22 1E 48 - Service 22
DID 1E48 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 10 voltage EUP_HVBAT_CELL_10_V
- Request
22 1E 49 - Service 22
DID 1E49 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 11 voltage EUP_HVBAT_CELL_11_V
- Request
22 1E 4A - Service 22
DID 1E4A - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 12 voltage EUP_HVBAT_CELL_12_V
- Request
22 1E 4B - Service 22
DID 1E4B - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 13 voltage EUP_HVBAT_CELL_13_V
- Request
22 1E 4C - Service 22
DID 1E4C - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 14 voltage EUP_HVBAT_CELL_14_V
- Request
22 1E 4D - Service 22
DID 1E4D - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 15 voltage EUP_HVBAT_CELL_15_V
- Request
22 1E 4E - Service 22
DID 1E4E - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 16 voltage EUP_HVBAT_CELL_16_V
- Request
22 1E 4F - Service 22
DID 1E4F - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 17 voltage EUP_HVBAT_CELL_17_V
- Request
22 1E 50 - Service 22
DID 1E50 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 18 voltage EUP_HVBAT_CELL_18_V
- Request
22 1E 51 - Service 22
DID 1E51 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 19 voltage EUP_HVBAT_CELL_19_V
- Request
22 1E 52 - Service 22
DID 1E52 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 20 voltage EUP_HVBAT_CELL_20_V
- Request
22 1E 53 - Service 22
DID 1E53 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 21 voltage EUP_HVBAT_CELL_21_V
- Request
22 1E 54 - Service 22
DID 1E54 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 22 voltage EUP_HVBAT_CELL_22_V
- Request
22 1E 55 - Service 22
DID 1E55 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 23 voltage EUP_HVBAT_CELL_23_V
- Request
22 1E 56 - Service 22
DID 1E56 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 24 voltage EUP_HVBAT_CELL_24_V
- Request
22 1E 57 - Service 22
DID 1E57 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 25 voltage EUP_HVBAT_CELL_25_V
- Request
22 1E 58 - Service 22
DID 1E58 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 26 voltage EUP_HVBAT_CELL_26_V
- Request
22 1E 59 - Service 22
DID 1E59 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 27 voltage EUP_HVBAT_CELL_27_V
- Request
22 1E 5A - Service 22
DID 1E5A - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 28 voltage EUP_HVBAT_CELL_28_V
- Request
22 1E 5B - Service 22
DID 1E5B - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 29 voltage EUP_HVBAT_CELL_29_V
- Request
22 1E 5C - Service 22
DID 1E5C - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 30 voltage EUP_HVBAT_CELL_30_V
- Request
22 1E 5D - Service 22
DID 1E5D - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 31 voltage EUP_HVBAT_CELL_31_V
- Request
22 1E 5E - Service 22
DID 1E5E - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 32 voltage EUP_HVBAT_CELL_32_V
- Request
22 1E 5F - Service 22
DID 1E5F - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 33 voltage EUP_HVBAT_CELL_33_V
- Request
22 1E 60 - Service 22
DID 1E60 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 34 voltage EUP_HVBAT_CELL_34_V
- Request
22 1E 61 - Service 22
DID 1E61 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 35 voltage EUP_HVBAT_CELL_35_V
- Request
22 1E 62 - Service 22
DID 1E62 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 36 voltage EUP_HVBAT_CELL_36_V
- Request
22 1E 63 - Service 22
DID 1E63 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 37 voltage EUP_HVBAT_CELL_37_V
- Request
22 1E 64 - Service 22
DID 1E64 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 38 voltage EUP_HVBAT_CELL_38_V
- Request
22 1E 65 - Service 22
DID 1E65 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 39 voltage EUP_HVBAT_CELL_39_V
- Request
22 1E 66 - Service 22
DID 1E66 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 40 voltage EUP_HVBAT_CELL_40_V
- Request
22 1E 67 - Service 22
DID 1E67 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 41 voltage EUP_HVBAT_CELL_41_V
- Request
22 1E 68 - Service 22
DID 1E68 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 42 voltage EUP_HVBAT_CELL_42_V
- Request
22 1E 69 - Service 22
DID 1E69 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 43 voltage EUP_HVBAT_CELL_43_V
- Request
22 1E 6A - Service 22
DID 1E6A - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 44 voltage EUP_HVBAT_CELL_44_V
- Request
22 1E 6B - Service 22
DID 1E6B - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 45 voltage EUP_HVBAT_CELL_45_V
- Request
22 1E 6C - Service 22
DID 1E6C - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 46 voltage EUP_HVBAT_CELL_46_V
- Request
22 1E 6D - Service 22
DID 1E6D - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 47 voltage EUP_HVBAT_CELL_47_V
- Request
22 1E 6E - Service 22
DID 1E6E - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 48 voltage EUP_HVBAT_CELL_48_V
- Request
22 1E 6F - Service 22
DID 1E6F - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 49 voltage EUP_HVBAT_CELL_49_V
- Request
22 1E 70 - Service 22
DID 1E70 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 50 voltage EUP_HVBAT_CELL_50_V
- Request
22 1E 71 - Service 22
DID 1E71 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 51 voltage EUP_HVBAT_CELL_51_V
- Request
22 1E 72 - Service 22
DID 1E72 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 52 voltage EUP_HVBAT_CELL_52_V
- Request
22 1E 73 - Service 22
DID 1E73 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 53 voltage EUP_HVBAT_CELL_53_V
- Request
22 1E 74 - Service 22
DID 1E74 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 54 voltage EUP_HVBAT_CELL_54_V
- Request
22 1E 75 - Service 22
DID 1E75 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 55 voltage EUP_HVBAT_CELL_55_V
- Request
22 1E 76 - Service 22
DID 1E76 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 56 voltage EUP_HVBAT_CELL_56_V
- Request
22 1E 77 - Service 22
DID 1E77 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 57 voltage EUP_HVBAT_CELL_57_V
- Request
22 1E 78 - Service 22
DID 1E78 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 58 voltage EUP_HVBAT_CELL_58_V
- Request
22 1E 79 - Service 22
DID 1E79 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 59 voltage EUP_HVBAT_CELL_59_V
- Request
22 1E 7A - Service 22
DID 1E7A - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 60 voltage EUP_HVBAT_CELL_60_V
- Request
22 1E 7B - Service 22
DID 1E7B - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 61 voltage EUP_HVBAT_CELL_61_V
- Request
22 1E 7C - Service 22
DID 1E7C - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 62 voltage EUP_HVBAT_CELL_62_V
- Request
22 1E 7D - Service 22
DID 1E7D - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 63 voltage EUP_HVBAT_CELL_63_V
- Request
22 1E 7E - Service 22
DID 1E7E - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 64 voltage EUP_HVBAT_CELL_64_V
- Request
22 1E 7F - Service 22
DID 1E7F - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 65 voltage EUP_HVBAT_CELL_65_V
- Request
22 1E 80 - Service 22
DID 1E80 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 66 voltage EUP_HVBAT_CELL_66_V
- Request
22 1E 81 - Service 22
DID 1E81 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 67 voltage EUP_HVBAT_CELL_67_V
- Request
22 1E 82 - Service 22
DID 1E82 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 68 voltage EUP_HVBAT_CELL_68_V
- Request
22 1E 83 - Service 22
DID 1E83 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 69 voltage EUP_HVBAT_CELL_69_V
- Request
22 1E 84 - Service 22
DID 1E84 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 70 voltage EUP_HVBAT_CELL_70_V
- Request
22 1E 85 - Service 22
DID 1E85 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 71 voltage EUP_HVBAT_CELL_71_V
- Request
22 1E 86 - Service 22
DID 1E86 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 72 voltage EUP_HVBAT_CELL_72_V
- Request
22 1E 87 - Service 22
DID 1E87 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 73 voltage EUP_HVBAT_CELL_73_V
- Request
22 1E 88 - Service 22
DID 1E88 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 74 voltage EUP_HVBAT_CELL_74_V
- Request
22 1E 89 - Service 22
DID 1E89 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 75 voltage EUP_HVBAT_CELL_75_V
- Request
22 1E 8A - Service 22
DID 1E8A - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 76 voltage EUP_HVBAT_CELL_76_V
- Request
22 1E 8B - Service 22
DID 1E8B - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 77 voltage EUP_HVBAT_CELL_77_V
- Request
22 1E 8C - Service 22
DID 1E8C - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 78 voltage EUP_HVBAT_CELL_78_V
- Request
22 1E 8D - Service 22
DID 1E8D - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 79 voltage EUP_HVBAT_CELL_79_V
- Request
22 1E 8E - Service 22
DID 1E8E - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 80 voltage EUP_HVBAT_CELL_80_V
- Request
22 1E 8F - Service 22
DID 1E8F - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 81 voltage EUP_HVBAT_CELL_81_V
- Request
22 1E 90 - Service 22
DID 1E90 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 82 voltage EUP_HVBAT_CELL_82_V
- Request
22 1E 91 - Service 22
DID 1E91 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 83 voltage EUP_HVBAT_CELL_83_V
- Request
22 1E 92 - Service 22
DID 1E92 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 84 voltage EUP_HVBAT_CELL_84_V
- Request
22 1E 93 - Service 22
DID 1E93 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 85 voltage EUP_HVBAT_CELL_85_V
- Request
22 1E 94 - Service 22
DID 1E94 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 86 voltage EUP_HVBAT_CELL_86_V
- Request
22 1E 95 - Service 22
DID 1E95 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 87 voltage EUP_HVBAT_CELL_87_V
- Request
22 1E 96 - Service 22
DID 1E96 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 88 voltage EUP_HVBAT_CELL_88_V
- Request
22 1E 97 - Service 22
DID 1E97 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 89 voltage EUP_HVBAT_CELL_89_V
- Request
22 1E 98 - Service 22
DID 1E98 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 90 voltage EUP_HVBAT_CELL_90_V
- Request
22 1E 99 - Service 22
DID 1E99 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 91 voltage EUP_HVBAT_CELL_91_V
- Request
22 1E 9A - Service 22
DID 1E9A - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 92 voltage EUP_HVBAT_CELL_92_V
- Request
22 1E 9B - Service 22
DID 1E9B - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 93 voltage EUP_HVBAT_CELL_93_V
- Request
22 1E 9C - Service 22
DID 1E9C - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 94 voltage EUP_HVBAT_CELL_94_V
- Request
22 1E 9D - Service 22
DID 1E9D - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 95 voltage EUP_HVBAT_CELL_95_V
- Request
22 1E 9E - Service 22
DID 1E9E - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 96 voltage EUP_HVBAT_CELL_96_V
- Request
22 1E 9F - Service 22
DID 1E9F - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 97 voltage EUP_HVBAT_CELL_97_V
- Request
22 1E A0 - Service 22
DID 1EA0 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 98 voltage EUP_HVBAT_CELL_98_V
- Request
22 1E A1 - Service 22
DID 1EA1 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 99 voltage EUP_HVBAT_CELL_99_V
- Request
22 1E A2 - Service 22
DID 1EA2 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 100 voltage EUP_HVBAT_CELL_100_V
- Request
22 1E A3 - Service 22
DID 1EA3 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 101 voltage EUP_HVBAT_CELL_101_V
- Request
22 1E A4 - Service 22
DID 1EA4 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell 102 voltage EUP_HVBAT_CELL_102_V
- Request
22 1E A5 - Service 22
DID 1EA5 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell voltage sum EUP_HVBAT_CELL_SUM_V
- Request
22 1E 3C - Service 22
DID 1E3C - Module
7E5 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 4095.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell voltage, maximum EUP_HVBAT_CELL_V_MAX
- Request
22 1E 33 - Service 22
DID 1E33 - Module
7E5 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery cell voltage, minimum EUP_HVBAT_CELL_V_MIN
- Request
22 1E 34 - Service 22
DID 1E34 - Module
7E5 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2013 to 2023.
HV battery charge EUP_HVBAT_SOC
Pelican can show this parameter as the state of charge.
- Request
22 02 8C - Service 22
DID 028C - Module
7E5 → 7ED - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 2013 to 2023.
HV battery charge current limit EUP_HVBAT_CHG_I_LIM
- Request
22 1E 1B - Service 22
DID 1E1B - Module
7E5 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 A
- Unit
- A
In testing for 2013 to 2023.
HV battery charge current limit, predicted EUP_HVBAT_CHG_I_LIM_PRED
- Request
22 1E 1D - Service 22
DID 1E1D - Module
7E5 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 A
- Unit
- A
In testing for 2013 to 2023.
HV battery charge throughput EUP_HVBAT_AH_CHG
- Request
22 1E 32 - Service 22
DID 1E32 - Module
7E5 → 7ED - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 549.31642)- Range
- 0 to 7818700 Ah
- Unit
- Ah
In testing for 2013 to 2023.
HV battery charge, displayed EUP_HVBAT_SOC_DISP
Pelican can show this parameter as the state of charge.
- Request
22 11 64 - Service 22
DID 1164 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2013 to 2023.
HV battery charge, normalized EUP_PE_SOC
- Request
22 F4 04 - Service 22
DID F404 - Module
7E6 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2.55)- Range
- 0 to 100 %
- Unit
- %
In testing for 2013 to 2023.
HV battery coldest sensor EUP_HVBAT_T_MIN_NO
- Request
22 1E 0F - Service 22
DID 1E0F - Module
7E5 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2023.
HV battery current EUP_HVBAT_I
Pelican can show this parameter as the traction battery current.
- Request
22 1E 3D - Service 22
DID 1E3D - Module
7E5 → 7ED - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4 − 511)- Range
- -200 to 200 A
- Unit
- A
In testing for 2013 to 2023.
HV battery discharge current limit EUP_HVBAT_DISCHG_I_LIM
- Request
22 1E 1C - Service 22
DID 1E1C - Module
7E5 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 A
- Unit
- A
In testing for 2013 to 2023.
HV battery discharge current limit, predicted EUP_HVBAT_DISCHG_I_LIM_PRED
- Request
22 1E 1E - Service 22
DID 1E1E - Module
7E5 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 A
- Unit
- A
In testing for 2013 to 2023.
HV battery discharge throughput EUP_HVBAT_AH_DISCHG
- Request
22 1E 32 - Service 22
DID 1E32 - Module
7E5 → 7ED - Every
3600 s - Testing
Bits 32 to 63 of the reply, 32 bits. The value is signed.
- Formula
(val ÷ 549.31642)- Range
- -3909350 to 3909350 Ah
- Unit
- Ah
In testing for 2013 to 2023.
HV battery energy EUP_HVBAT_KWH
Energy stored in the high voltage battery
- Request
22 2A B8 - Service 22
DID 2AB8 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 1310770)- Range
- 0 to 3276 kWh
- Unit
- kWh
In testing for 2013 to 2023.
HV battery energy charged EUP_HVBAT_KWH_CHG
- Request
22 1E 32 - Service 22
DID 1E32 - Module
7E5 → 7ED - Every
3600 s - Testing
Bits 64 to 95 of the reply, 32 bits.
- Formula
(val ÷ 8583.07212)- Range
- 0 to 500300 kWh
- Unit
- kWh
In testing for 2013 to 2023.
HV battery energy discharged EUP_HVBAT_KWH_DISCHG
- Request
22 1E 32 - Service 22
DID 1E32 - Module
7E5 → 7ED - Every
3600 s - Testing
Bits 96 to 127 of the reply, 32 bits. The value is signed.
- Formula
(val ÷ 8583.07212)- Range
- -250199.883 to 250199.883 kWh
- Unit
- kWh
In testing for 2013 to 2023.
HV battery health EUP_HVBAT_SOH
Pelican can show this parameter as the state of health.
- Request
22 51 E0 - Service 22
DID 51E0 - Module
7E5 → 7ED - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.127 − 1798.574)- Range
- -1798.574 to 100 %
- Unit
- %
In testing for 2013 to 2023.
HV battery highest cell EUP_HVBAT_CELL_V_MAX_NO
- Request
22 1E 33 - Service 22
DID 1E33 - Module
7E5 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2023.
HV battery hottest sensor EUP_HVBAT_T_MAX_NO
- Request
22 1E 0E - Service 22
DID 1E0E - Module
7E5 - Every
5 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2023.
HV battery isolation resistance, negative EUP_HVBAT_ISO_NEG
- Request
22 1E 1A - Service 22
DID 1E1A - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 kΩ
- Unit
- kΩ
In testing for 2013 to 2023.
HV battery isolation resistance, positive EUP_HVBAT_ISO_POS
- Request
22 1E 18 - Service 22
DID 1E18 - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 kΩ
- Unit
- kΩ
In testing for 2013 to 2023.
HV battery lowest cell EUP_HVBAT_CELL_V_MIN_NO
- Request
22 1E 34 - Service 22
DID 1E34 - Module
7E5 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2023.
HV battery maximum power EUP_HVBAT_PWR_MAX
- Request
22 15 02 - Service 22
DID 1502 - Module
7E0 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 4)- Range
- 0 to 262140 W
- Unit
- W
In testing for 2013 to 2023.
HV battery negative voltage before the contactors EUP_HVBAT_NEG_V_PRE
- Request
22 1E 35 - Service 22
DID 1E35 - Module
7E5 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 32)- Range
- -1024 to 1023.968 V
- Unit
- V
In testing for 2013 to 2023.
HV battery positive voltage after the charging contactors EUP_HVBAT_POS_V_POST_CHG
- Request
22 1E 39 - Service 22
DID 1E39 - Module
7E5 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047.937 V
- Unit
- V
In testing for 2013 to 2023.
HV battery positive voltage before the contactors EUP_HVBAT_POS_V_PRE
- Request
22 1E 36 - Service 22
DID 1E36 - Module
7E5 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.968 V
- Unit
- V
In testing for 2013 to 2023.
HV battery power EUP_HVBAT_PWR
- Request
22 14 85 - Service 22
DID 1485 - Module
7E0 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 250)- Range
- -131.072 to 131.068 kW
- Unit
- kW
In testing for 2013 to 2023.
HV battery relative temperature EUP_HVBAT_T_REL
- Request
22 14 9B - Service 22
DID 149B - Module
7E0 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 %
- Unit
- %
In testing for 2013 to 2023.
HV battery remaining charge EUP_HVBAT_REMAINING
- Request
22 F4 5B - Service 22
DID F45B - Module
7E0 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2.55)- Range
- 0 to 100 %
- Unit
- %
In testing for 2013 to 2023.
HV battery temperature EUP_HVBAT_T
- Request
22 2A 0B - Service 22
DID 2A0B - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2013 to 2023.
HV battery temperature load EUP_HVBAT_T_LOAD
- Request
22 11 65 - Service 22
DID 1165 - Module
7E0 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 %
- Unit
- %
In testing for 2013 to 2023.
HV battery temperature sensor 1 EUP_HVBAT_T_1
- Request
22 1E AE - Service 22
DID 1EAE - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2013 to 2023.
HV battery temperature sensor 2 EUP_HVBAT_T_2
- Request
22 1E AF - Service 22
DID 1EAF - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2013 to 2023.
HV battery temperature sensor 3 EUP_HVBAT_T_3
- Request
22 1E B0 - Service 22
DID 1EB0 - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2013 to 2023.
HV battery temperature sensor 4 EUP_HVBAT_T_4
- Request
22 1E B1 - Service 22
DID 1EB1 - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2013 to 2023.
HV battery temperature sensor 5 EUP_HVBAT_T_5
- Request
22 1E B2 - Service 22
DID 1EB2 - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2013 to 2023.
HV battery temperature sensor 6 EUP_HVBAT_T_6
- Request
22 1E B3 - Service 22
DID 1EB3 - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2013 to 2023.
HV battery temperature sensor 7 EUP_HVBAT_T_7
- Request
22 1E B4 - Service 22
DID 1EB4 - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2013 to 2023.
HV battery temperature sensor 8 EUP_HVBAT_T_8
- Request
22 1E B5 - Service 22
DID 1EB5 - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2013 to 2023.
HV battery temperature sensor 9 EUP_HVBAT_T_9
- Request
22 1E B6 - Service 22
DID 1EB6 - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2013 to 2023.
HV battery temperature sensor 10 EUP_HVBAT_T_10
- Request
22 1E B7 - Service 22
DID 1EB7 - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2013 to 2023.
HV battery temperature sensor 11 EUP_HVBAT_T_11
- Request
22 1E B8 - Service 22
DID 1EB8 - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2013 to 2023.
HV battery temperature sensor 12 EUP_HVBAT_T_12
- Request
22 1E B9 - Service 22
DID 1EB9 - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2013 to 2023.
HV battery temperature sensor 13 EUP_HVBAT_T_13
- Request
22 1E BA - Service 22
DID 1EBA - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2013 to 2023.
HV battery temperature sensor 15 EUP_HVBAT_T_15
- Request
22 1E BC - Service 22
DID 1EBC - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2013 to 2023.
HV battery temperature sensor 16 EUP_HVBAT_T_16
- Request
22 1E BD - Service 22
DID 1EBD - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2013 to 2023.
HV battery temperature sensor 17 EUP_HVBAT_T_17
- Request
22 74 25 - Service 22
DID 7425 - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2013 to 2023.
HV battery temperature, maximum EUP_HVBAT_T_MAX
- Request
22 1E 0E - Service 22
DID 1E0E - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2013 to 2023.
HV battery voltage EUP_HVBAT_V
Pelican can show this parameter as the traction battery voltage.
- Request
22 1E 3B - Service 22
DID 1E3B - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 1000 V
- Unit
- V
In testing for 2013 to 2023.
HV interlock detector voltage EUP_HV_INTERLOCK_DET_V
- Request
22 74 B9 - Service 22
DID 74B9 - Module
7E5 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 3276)- Range
- 0 to 20.004 V
- Unit
- V
In testing for 2013 to 2023.
HV interlock source current EUP_HV_INTERLOCK_SRC_I
- Request
22 74 BC - Service 22
DID 74BC - Module
7E5 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 mA
- Unit
- mA
In testing for 2013 to 2023.
HV interlock source voltage EUP_HV_INTERLOCK_SRC_V
- Request
22 74 BA - Service 22
DID 74BA - Module
7E5 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 3276)- Range
- 0 to 20.004 V
- Unit
- V
In testing for 2013 to 2023.
HV system isolation resistance, negative EUP_HV_ISO_NEG_SYS
- Request
22 1E 19 - Service 22
DID 1E19 - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 kΩ
- Unit
- kΩ
In testing for 2013 to 2023.
HV system isolation resistance, positive EUP_HV_ISO_POS_SYS
- Request
22 1E 17 - Service 22
DID 1E17 - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 kΩ
- Unit
- kΩ
In testing for 2013 to 2023.
Onboard electrical system current EUP_AUX_I
- Request
22 16 17 - Service 22
DID 1617 - Module
7E0 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 32)- Range
- -1024 to 1023.968 A
- Unit
- A
In testing for 2013 to 2023.
Onboard electrical system power EUP_AUX_PWR
- Request
22 10 77 - Service 22
DID 1077 - Module
7E0 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 4)- Range
- 0 to 262140 W
- Unit
- W
In testing for 2013 to 2023.
Power electronics terminal 30 voltage EUP_PE_KL30_V
- Request
22 46 5D - Service 22
DID 465D - Module
7E6 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 512)- Range
- -64 to 63.998 V
- Unit
- V
In testing for 2013 to 2023.
Terminal 30 voltage EUP_KL30_V
Pelican can show this parameter as the starter battery voltage.
- Request
22 F4 42 - Service 22
DID F442 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65 V
- Unit
- V
In testing for 2013 to 2023.
Traction current reported by the battery management system EUP_PE_BMS_HV_I
- Request
22 46 5F - Service 22
DID 465F - Module
7E6 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047.937 A
- Unit
- A
In testing for 2013 to 2023.
Traction voltage reported by the battery management system EUP_PE_BMS_HV_V
- Request
22 46 6E - Service 22
DID 466E - Module
7E6 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.968 V
- Unit
- V
In testing for 2013 to 2023.