Volkswagen e-Up

Climate parameters

The Volkswagen e-Up has 5 climate parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Air conditioning refrigerant pressure EUP_AC_REFRIG_P

  • Request22 10 17
  • Service 22DID 1017
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 13107 kPa
Unit
kPa

In testing for 2013 to 2023.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Air conditioning refrigerant pressure EUP_AC_REFRIG_P

  • Request22 10 17
  • Service 22DID 1017
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 13107 kPa
Unit
kPa

In testing for 2013 to 2023.

Ambient air temperature EUP_AAT

  • Request22 F4 46
  • Service 22DID F446
  • Module7E0
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2013 to 2023.

Ambient air temperature, cluster EUP_DASH_AAT

  • Request22 10 14
  • Service 22DID 1014
  • Module714 → 77E
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2 − 50)
Range
-50 to 77.5 °C
Unit
°C

In testing for 2013 to 2023.

Barometric pressure EUP_BARO

  • Request22 F4 33
  • Service 22DID F433
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

In testing for 2013 to 2023.

PTC heater current EUP_PTC_HEATER_I

  • Request22 16 04
  • Service 22DID 1604
  • Module7E0
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 16)
Range
0 to 15.937 A
Unit
A

In testing for 2013 to 2023.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.