The Volvo XC60 has 64 battery parameters.
● Confirmed◆ In testing○ Supported× Not supported
All-wheel drive coupling module voltage XC60_MECU_V
- Request
22 DD 02 - Service 22
DID DD02 - Module
795 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 4)- Range
- 0 to 63.75 V
- Unit
- V
In testing for 1997, 2008 to 2017.
Alternator charge voltage request XC60_ALTERNATOR_CHG_V_REQ
- Request
22 41 1D - Service 22
DID 411D - Module
726 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 1997, 2008 to 2017.
Auxiliary battery current XC60_AUXILIARY_BAT
- Request
22 41 12 - Service 22
DID 4112 - Module
D01A → 1F402E80 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 127)- Range
- -127 to 128 A
- Unit
- A
In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.
Auxiliary battery temperature XC60_AUXILIARY_BAT_T
- Request
22 40 D3 - Service 22
DID 40D3 - Module
D01A → 1F402E80 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.
Auxiliary battery voltage XC60_AUXILIARY_BAT_V
Pelican can show this parameter as the starter battery voltage.
- Request
22 41 7E - Service 22
DID 417E - Module
D01A → 1F402E80 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.
Average static low range battery current XC60_AVG_STATIC_LOW_RANGE
- Request
22 40 25 - Service 22
DID 4025 - Module
D01A → 1F402E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val − 511)- Range
- -511 to 65024 mA
- Unit
- mA
In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.
Battery charge balance, ah XC60_BAT_CHG_BALANCE_AH
- Request
22 41 A5 - Service 22
DID 41A5 - Module
726 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1997, 2008 to 2017.
Battery charge, amps XC60_BAT_CHG_AMPS
- Request
22 40 90 - Service 22
DID 4090 - Module
726 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 511.7)- Range
- -511 to 3584 A
- Unit
- A
In testing for 1997, 2008 to 2017.
Battery current XC60_BAT_CURRENT
- Request
22 40 90 - Service 22
DID 4090 - Module
D01A → 1F402E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 512)- Range
- -512 to 3583 A
- Unit
- A
In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.
Battery operation time since battery monitoring sensor reset, days XC60_BAT_OPERATION_TIME
- Request
22 40 27 - Service 22
DID 4027 - Module
726 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1997, 2008 to 2017.
Battery relay XC60_BAT_RELAY
- Request
22 D9 53 - Service 22
DID D953 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1997, 2008 to 2021.
Battery state of charge XC60_BAT_ST_CHG
- Request
22 40 28 - Service 22
DID 4028 - Module
D01A → 1F402E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 %
- Unit
- %
In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.
Battery state of charge XC60_BAT_ST_CHG_726
- Request
22 40 28 - Service 22
DID 4028 - Module
726 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 1997, 2008 to 2017.
Battery temperature XC60_BAT_T
- Request
22 40 29 - Service 22
DID 4029 - Module
726 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1997, 2008 to 2017.
Battery voltage XC60_BAT_V
Pelican can show this parameter as the starter battery voltage.
- Request
22 40 CD - Service 22
DID 40CD - Module
D01A → 1F402E80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 40 + 5)- Range
- 0 to 1643 V
- Unit
- V
In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.
Battery voltage XC60_BAT_V_726
Pelican can show this parameter as the starter battery voltage.
- Request
22 40 2A - Service 22
DID 402A - Module
726 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 20 + 6)- Range
- 0 to 18.75 V
- Unit
- V
In testing for 1997, 2008 to 2017.
Boost pressure after turbocharger XC60_BOOST_P_AFTER
- Request
22 03 3E - Service 22
DID 033E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 131 − 0.053435)- Range
- -0.0534 to 500 kPa
- Unit
- kPa
In testing for 1997, 2008 to 2021.
Charger cable current XC60_CHARGER_CABLE
- Request
22 EE 8D - Service 22
DID EE8D - Module
D016 → 1EC68E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 410)- Range
- -410 to 6143 A
- Unit
- A
In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.
Charging socket lock XC60_CHG_SOCKET_LOCKED
- Request
22 EE 8C - Service 22
DID EE8C - Module
D016 → 1EC68E80 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | UNLOCKED | Unlocked |
2 | LOCKED | Locked |
In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Request
01 42 - Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65535 V
- Unit
- V
Confirmed for 2012, 2015, 2020, 2024 to 2025. Supported for 1997, 2016 to 2019, 2021 to 2023, 2026.
Control module voltage XC60_CTRL_MODULE_V_MS_CAN
- Request
22 D9 04 - Service 22
DID D904 - Module
784 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 V
- Unit
- V
In testing for 1997, 2008 to 2017.
DC charger current XC60_DC_CHARGER_CURRENT
- Request
22 EE 16 - Service 22
DID EE16 - Module
D016 → 1EC68E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 A
- Unit
- A
In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.
DC charger voltage XC60_DC_CHARGER_V
- Request
22 EE 17 - Service 22
DID EE17 - Module
D016 → 1EC68E80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 V
- Unit
- V
In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.
Enhanced Hybrid/EV Vehicle Charging State EHEV_MODESAE J1979Confirmed
- Request
01 9A - Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bits 1 to 2 of the reply, 2 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | CSM | Charge sustaining mode |
1 | CDM | Charge depleting mode |
2 | CIM | Charge increasing mode |
Confirmed for 2024. Supported for 2019, 2021.
Front camera voltage supply XC60_FRONT_CAMERA_V_SUP
- Request
22 99 69 - Service 22
DID 9969 - Module
764 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 2 ÷ 25)- Range
- 0 to 20.4 V
- Unit
- V
In testing for 1997, 2008 to 2017.
High voltage battery current XC60_HVBAT_CURRENT
Pelican can show this parameter as the traction battery current.
- Request
22 48 02 - Service 22
DID 4802 - Module
D016 → 1EC6AE80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 50)- Range
- -655 to 655 A
- Unit
- A
In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.
High voltage battery state of charge XC60_HVBAT_ST_CHG
Pelican can show this parameter as the state of charge.
- Request
22 48 01 - Service 22
DID 4801 - Module
D016 → 1EC6AE80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 500)- Range
- 0 to 131 %
- Unit
- %
In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.
High voltage battery voltage XC60_HVBAT_V
Pelican can show this parameter as the traction battery voltage.
- Request
22 48 03 - Service 22
DID 4803 - Module
D016 → 1EC6AE80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 V
- Unit
- V
In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.
High voltage battery, average temperature XC60_HVBAT_AVG_T
- Request
22 49 1B - Service 22
DID 491B - Module
D016 → 1EC6AE80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100 − 50)- Range
- -50 to 605 °C
- Unit
- °C
In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.
High voltage battery, coolant pump speed, actual XC60_HVBAT_CLT_PMP_SPD_ACT
- Request
22 48 67 - Service 22
DID 4867 - Module
D016 → 1EC6AE80 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 24)- Range
- 0 to 6120 rpm
- Unit
- rpm
In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.
High voltage battery, coolant pump speed, requested XC60_HVBAT_CLT_PMP_SPD
- Request
22 48 66 - Service 22
DID 4866 - Module
D016 → 1EC6AE80 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 24)- Range
- 0 to 6120 rpm
- Unit
- rpm
In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.
High voltage battery, high-voltage coolant heater fuse voltage XC60_HVBAT_HVCH_FUSE_V
- Request
22 48 0A - Service 22
DID 480A - Module
D016 → 1EC6AE80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 V
- Unit
- V
In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.
High voltage battery, IEM fuse voltage XC60_HVBAT_IEM_FUSE_V
- Request
22 48 08 - Service 22
DID 4808 - Module
D016 → 1EC6AE80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 V
- Unit
- V
In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.
High voltage battery, IGM fuse voltage XC60_HVBAT_IGM_FUSE_V
- Request
22 48 09 - Service 22
DID 4809 - Module
D016 → 1EC6AE80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 V
- Unit
- V
In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.
High voltage battery, inlet coolant temperature XC60_HVBAT_INLET_ECT
- Request
22 48 04 - Service 22
DID 4804 - Module
D016 → 1EC6AE80 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.
High voltage battery, max temperature XC60_HVBAT_MAX_T
- Request
22 49 45 - Service 22
DID 4945 - Module
D016 → 1EC6AE80 - Every
5 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 100 − 50)- Range
- -50 to 605 °C
- Unit
- °C
In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.
High voltage battery, OBC fuse voltage XC60_HVBAT_OBC_FUSE_V
- Request
22 48 0B - Service 22
DID 480B - Module
D016 → 1EC6AE80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 V
- Unit
- V
In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.
Hybrid battery pack remaining charge BAT_SOCSAE J1979Confirmed
The percent remaining level of charge for a battery pack used for propulsion, expressed as a percentage of total useable battery energy, commonly referred to as State Of Charge (SOC).
Pelican can show this parameter as the state of charge.
- Request
01 5B - Service 01
PID 5B - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2020, 2022, 2024 to 2026. Supported for 2018 to 2019, 2021, 2023.
Hybrid/EV Battery System Current HEV_BATT_ASAE J1979Confirmed
- Request
01 9A - Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bits 32 to 47 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 A
- Unit
- A
Confirmed for 2024. Supported for 2019, 2021.
Hybrid/EV Battery System Voltage HEV_BATT_VSAE J1979Confirmed
- Request
01 9A - Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.98 V
- Unit
- V
Confirmed for 2024. Supported for 2019, 2021.
Hybrid/EV Vehicle Charging State HEV_MODESAE J1979Confirmed
- Request
01 9A - Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bit 0 of the reply.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | CSM | Charge sustaining mode |
1 | CDM | Charge depleting mode |
Confirmed for 2024. Supported for 2019, 2021.
Main charger current XC60_MAIN_CHARGER_CURRENT
- Request
22 EE 15 - Service 22
DID EE15 - Module
D016 → 1EC68E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 A
- Unit
- A
In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.
Main charger voltage XC60_MAIN_CHARGER_V
- Request
22 EE 1C - Service 22
DID EE1C - Module
D016 → 1EC68E80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.
Module voltage XC60_MODULE_V
- Request
22 D1 11 - Service 22
DID D111 - Module
D016 → 1EC70E80 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.
Secondary battery charge time XC60_SECONDARY_BAT_CHG
- Request
22 EE D3 - Service 22
DID EED3 - Module
726 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 s
- Unit
- s
In testing for 1997, 2008 to 2017.
Secondary battery needed charge time XC60_SECONDARY_BAT_NEEDED
- Request
22 EE D5 - Service 22
DID EED5 - Module
726 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 s
- Unit
- s
In testing for 1997, 2008 to 2017.
Secondary battery relay XC60_SECONDARY_BAT_RELAY
- Request
22 41 9C - Service 22
DID 419C - Module
726 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1997, 2008 to 2017.
Secondary battery temperature XC60_SECONDARY_BAT_T_25_C
- Request
22 EE D2 - Service 22
DID EED2 - Module
726 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1997, 2008 to 2017.
Secondary battery voltage XC60_SECONDARY_BAT_V
- Request
22 41 7E - Service 22
DID 417E - Module
726 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 1997, 2008 to 2017.
Secondary battery voltage average value XC60_SECONDARY_BAT_V_AVG
- Request
22 EE D7 - Service 22
DID EED7 - Module
726 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 1997, 2008 to 2017.
Secondary battery voltage latest stored XC60_SECONDARY_BAT_V_LATEST
- Request
22 EE D4 - Service 22
DID EED4 - Module
726 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 1997, 2008 to 2017.
Servo supply voltage XC60_SERVO_SUP_V
- Request
22 41 3D - Service 22
DID 413D - Module
730 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 1997, 2008 to 2017.
Start/stop battery relay XC60_START_STOP_BAT_RELAY
- Request
22 EF 51 - Service 22
DID EF51 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1997, 2008 to 2021.
Start/stop secondary battery relay XC60_START_STOP_SECONDARY
- Request
22 EF 52 - Service 22
DID EF52 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1997, 2008 to 2021.
Supercharger clutch, requested position XC60_SUPERCHARGER_CLU_REQ
- Request
22 EE 84 - Service 22
DID EE84 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1997, 2008 to 2021.
Transmission control module supply voltage XC60_MECU_SUP_V
- Request
22 DD 02 - Service 22
DID DD02 - Module
7E1 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 4)- Range
- 0 to 63.75 V
- Unit
- V
In testing for 1997, 2008 to 2021.
Voltage supply XC60_V_SUP
- Request
22 D9 01 - Service 22
DID D901 - Module
737 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 2 ÷ 25)- Range
- 0 to 20.4 V
- Unit
- V
In testing for 1997, 2008 to 2017.
Voltage supply XC60_V_SUP_764
- Request
22 D1 12 - Service 22
DID D112 - Module
764 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 2 ÷ 25)- Range
- 0 to 20.4 V
- Unit
- V
In testing for 1997, 2008 to 2017.
Voltage supply XC60_V_SUP_MS_CAN
- Request
22 D1 11 - Service 22
DID D111 - Module
791 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 1997, 2008 to 2017.
Voltage/power sensitive loads connected XC60_V_POWER_SENSITIVE
- Request
22 EE A2 - Service 22
DID EEA2 - Module
726 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1997, 2008 to 2017.
Battery › Internal
Enhanced Hybrid/EV Vehicle Charging State supported? EHEV_MODE_SUPSAE J1979Confirmed
- Request
01 9A - Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024. Supported for 2019, 2021.
Hybrid/EV Battery Current supported? HEV_BATT_A_SUPSAE J1979Confirmed
- Request
01 9A - Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024. Supported for 2019, 2021.
Hybrid/EV Battery Voltage supported? HEV_BATT_V_SUPSAE J1979Confirmed
- Request
01 9A - Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024. Supported for 2019, 2021.
Hybrid/EV Vehicle Charging State supported? HEV_MODE_SUPSAE J1979Confirmed
- Request
01 9A - Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024. Supported for 2019, 2021.