Volvo XC60

Fuel parameters

The Volvo XC60 has 24 fuel parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Engine exhaust flow rate EXH_RATEConfirmed

  • Request01 9E
  • Service 01PID 9E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 13107 kg/h
Unit
kg/h

Confirmed for 2020, 2022, 2024 to 2025. Supported for 2019, 2021.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Engine exhaust flow rate EXH_RATESAE J1979Confirmed

  • Request01 9E
  • Service 01PID 9E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 13107 kg/h
Unit
kg/h

Confirmed for 2020, 2022, 2024 to 2025. Supported for 2019, 2021.

Engine fuel rate FUEL_RATESAE J1979Confirmed

Measured in units per hour

Pelican can show this parameter as the fuel rate.

  • Request01 5E
  • Service 01PID 5E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 20)
Range
0 to 3212.75 L/h
Unit
L/h

Confirmed for 2022, 2024 to 2026. Supported for 2017, 2019 to 2021, 2023.

Engine fuel rate (alternate) FUEL_RATE_ALTSAE J1979Confirmed

  • Request01 9D
  • Service 01PID 9D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 50)
Range
0 to 1310.7 g/s
Unit
g/s

Confirmed for 2020, 2022, 2024 to 2025. Supported for 2019, 2021.

Fuel filter heater XC60_FUEL_FLT_HEATER

  • Request22 DC 14
  • Service 22DID DC14
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2021.

Fuel filter heater XC60_FUEL_FLT_HEATER_7E0

  • Request22 DB 35
  • Service 22DID DB35
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2021.

Fuel heater fan adjustment XC60_FUEL_HEATER_FAN_ADJ

  • Request22 9A 03
  • Service 22DID 9A03
  • Module7E3
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 V
Unit
V

In testing for 1997, 2008 to 2017.

Fuel level 1 of 2 XC60_DIM_FLI_1_2

  • Request22 61 D1
  • Service 22DID 61D1
  • Module720
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 L
Unit
L

In testing for 1997, 2008 to 2017.

Fuel level 2 of 2 ejector side saddle tank XC60_DIM_FLI_2_2_EJECTOR

  • Request22 61 D0
  • Service 22DID 61D0
  • Module720
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 L
Unit
L

In testing for 1997, 2008 to 2017.

Fuel level damped XC60_DIM_FLI_DAMPED

  • Request22 EE 11
  • Service 22DID EE11
  • Module720
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 13107 L
Unit
L

In testing for 1997, 2008 to 2017.

Fuel level damped XC60_FLI_DAMPED

  • Request22 EE 12
  • Service 22DID EE12
  • Module720
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 13107 L
Unit
L

In testing for 1997, 2008 to 2017.

Fuel level input XC60_FLI_INPUT

Pelican can show this parameter as the fuel tank level.

  • Request22 F4 2F
  • Service 22DID F42F
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 1997, 2008 to 2021.

Fuel level sensor XC60_FLI_SENS

  • Request22 41 17
  • Service 22DID 4117
  • Module726
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 100 ÷ 20459)
Range
0 to 320 V
Unit
V

In testing for 1997, 2008 to 2017.

Fuel level sensor ejector side saddle tank XC60_FLI_SENS_EJECTOR

  • Request22 41 18
  • Service 22DID 4118
  • Module726
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 100 ÷ 20459)
Range
0 to 320 V
Unit
V

In testing for 1997, 2008 to 2017.

Fuel pressure XC60_FUEL_P

  • Request22 F4 23
  • Service 22DID F423
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 100)
Range
0 to 6553500
Unit
Raw value

In testing for 1997, 2008 to 2021.

Fuel pressure nominal value XC60_FUEL_P_NOMINAL

  • Request22 D9 FF
  • Service 22DID D9FF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 100)
Range
0 to 6553500
Unit
Raw value

In testing for 1997, 2008 to 2021.

Fuel pressure regulator valve current XC60_FUEL_P_REGULATOR_VLV

  • Request22 D9 EE
  • Service 22DID D9EE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1997, 2008 to 2021.

Fuel pump low pressure side duty cycle XC60_FUEL_PMP_LOW_P_SIDE

  • Request22 EF 59
  • Service 22DID EF59
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 %
Unit
%

In testing for 1997, 2008 to 2021.

Fuel system 1 status FUELSYS1SAE J1979Confirmed

  • Request01 03
  • Service 01PID 03
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFEngine is off
1OLOpen loop - has not yet satisfied conditions to go closed loop
2CLClosed loop - using oxygen sensor(s) as feedback for fuel control
4OL-DriveOpen loop due to driving conditions (e.g. power enrichment, deceleration enleanment)
8OL-FaultOpen loop - due to detected system fault
16CL-FaultClosed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control
32OL B2Open loop - has not yet satisfied conditions to go closed loop (Bank 2)
64OL-Drive B2Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
128OL-Fault B2Open loop - due to detected system fault (Bank 2)

Confirmed for 2012, 2020, 2022, 2024 to 2025. Supported for 2016, 2018 to 2019, 2021, 2023, 2026.

Fuel system 2 status FUELSYS2SAE J1979Confirmed

  • Request01 03
  • Service 01PID 03
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFEngine is off
1OLOpen loop - has not yet satisfied conditions to go closed loop
2CLClosed loop - using oxygen sensor(s) as feedback for fuel control
4OL-DriveOpen loop due to driving conditions (e.g. power enrichment, deceleration enleanment)
8OL-FaultOpen loop - due to detected system fault
16CL-FaultClosed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control
32OL B2Open loop - has not yet satisfied conditions to go closed loop (Bank 2)
64OL-Drive B2Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
128OL-Fault B2Open loop - due to detected system fault (Bank 2)

Confirmed for 2012, 2020, 2022, 2024 to 2025. Supported for 2016, 2018 to 2019, 2021, 2023, 2026.

Fuel tank level FLISAE J1979Confirmed

Pelican can show this parameter as the fuel tank level.

  • Request01 2F
  • Service 01PID 2F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2012, 2015, 2020, 2022, 2024 to 2026. Supported for 1997, 2016 to 2019, 2021, 2023.

Fuel temperature XC60_FUEL_T

  • Request22 D9 9C
  • Service 22DID D99C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273)
Range
-3549 to 3003 °C
Unit
°C

In testing for 1997, 2008 to 2021.

Fuel volume control valve XC60_FUEL_VOLUME_CTRL_VLV

  • Request22 DA D5
  • Service 22DID DAD5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 %
Unit
%

In testing for 1997, 2008 to 2021.

Fuel volume control valve XC60_FUEL_VOLUME_CTRL_VLV_7E0

  • Request22 DC 13
  • Service 22DID DC13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 %
Unit
%

In testing for 1997, 2008 to 2021.

Vehicle fuel rate VFUEL_RATESAE J1979Confirmed

  • Request01 9D
  • Service 01PID 9D
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 50)
Range
0 to 1310.7 g/s
Unit
g/s

Confirmed for 2020, 2022, 2024 to 2025. Supported for 2019, 2021.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.