Hyundai Palisade

Climate parameters

The Hyundai Palisade has 4 climate parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Defogging? PALISADE_DEFOG_SWConfirmed

  • Request22 BC 03
  • Service 22DID BC03
  • Module770 → 778
  • Every1 s
  • Testing for 2018 to 2019

Example reply from a 2025 Hyundai Palisade.

Bit 62 of the reply.

0b0 = 0 → 0

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020 to 2025. In testing for 2018 to 2019. Supported for 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

A/C compressor operation RPM PALISADE_AC_COMPRESSOR_OPERATION_RPM

  • Request22 01 14
  • Service 22DID 0114
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
(val × 20)
Range
0 to 1310700 rpm
Unit
rpm

Not supported for 2023 to 2024, 2026.

Defogging? PALISADE_DEFOG_SWConfirmed

  • Request22 BC 03
  • Service 22DID BC03
  • Module770 → 778
  • Every1 s
  • Testing for 2018 to 2019

Example reply from a 2025 Hyundai Palisade.

Bit 62 of the reply.

0b0 = 0 → 0

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020 to 2025. In testing for 2018 to 2019. Supported for 2026.

Interior temperature, passenger legs vent PALISADE_HVAC_IAT_PASSENGER_LEGS_VENTConfirmed

  • Request22 01 01
  • Service 22DID 0101
  • Module7B3 → 7BB
  • Every5 s
  • Testing for 2018 to 2022, 2025

Example reply from a 2026 Hyundai Palisade.

Bits 72 to 79 of the reply, 8 bits.

0xFF = 255 → (255 ÷ 2 − 40) = 87.5 °C

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

Confirmed for 2023 to 2024, 2026. In testing for 2018 to 2022, 2025.

Interior temperature, passenger vent PALISADE_HVAC_IAT_PASSENGER_VENTConfirmed

  • Request22 01 01
  • Service 22DID 0101
  • Module7B3 → 7BB
  • Every5 s
  • Testing for 2018 to 2022, 2025

Example reply from a 2026 Hyundai Palisade.

Bits 64 to 71 of the reply, 8 bits.

0xFF = 255 → (255 ÷ 2 − 40) = 87.5 °C

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

Confirmed for 2023 to 2024, 2026. In testing for 2018 to 2022, 2025.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.