Kia K5

Battery parameters

The Kia K5 has 11 battery parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

12v battery voltage K5_VPWRConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Request22 B0 02
  • Service 22DID B002
  • Module7C6 → 7CE
  • Every5 s
  • Testing for 2000 to 2020, 2024

Example reply from a 2026 Kia K5.

Bits 40 to 47 of the reply, 8 bits.

0xAE = 174 → (174 ÷ 12.8) = 13.59375 V

Formula
(val ÷ 12.8)
Range
0 to 18 V
Unit
V

Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2000 to 2020. Not supported for 2024.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

12v battery voltage K5_VPWRConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Request22 B0 02
  • Service 22DID B002
  • Module7C6 → 7CE
  • Every5 s
  • Testing for 2000 to 2020, 2024

Example reply from a 2026 Kia K5.

Bits 40 to 47 of the reply, 8 bits.

0xAE = 174 → (174 ÷ 12.8) = 13.59375 V

Formula
(val ÷ 12.8)
Range
0 to 18 V
Unit
V

Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2000 to 2020. Not supported for 2024.

Control module voltage K5_CONTROL_MODULE_VOLTAGE

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255 V
Unit
V

In testing for 2000 to 2020. Not supported for 2021 to 2026.

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Request01 42
  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65535 V
Unit
V

Confirmed for 2022 to 2023, 2025 to 2026. Supported for 2015, 2021, 2024.

Control module voltage after ignition K5_CONTROL_MODULE_VOLTAGE_AFTER_IGNITION

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255 V
Unit
V

In testing for 2000 to 2020. Not supported for 2021 to 2026.

Coolant temperature sensor voltage K5_COOLANT_T_SENSOR_VOLTAGE

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 184 to 199 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 0.0048828125)
Range
0 to 319 V
Unit
V

In testing for 2000 to 2020. Not supported for 2021 to 2026.

IAT sensor voltage K5_IAT_SENSOR_VOLTAGE

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 248 to 263 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 0.0048828125)
Range
0 to 319 V
Unit
V

In testing for 2000 to 2020. Not supported for 2021 to 2026.

Manifold absolute pressure sensor voltage K5_MAP_SENSOR_VOLTAGE

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 127 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 0.0048828125)
Range
0 to 319 V
Unit
V

In testing for 2000 to 2020. Not supported for 2021 to 2026.

Relative accelerator pedal position voltage K5_RELATIVE_ACCELERATOR_PEDAL_POSITION_VOLTAGE

  • Request21 14
  • Service 21PID 14
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 127 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val ÷ 5)
Range
-6553.6 to 6553.4 V
Unit
V

In testing for 2000 to 2020. Not supported for 2021 to 2026.

Throttle position sensor voltage #1 K5_THROTTLE_POSITION_SENSOR_VOLTAGE__1

  • Request21 14
  • Service 21PID 14
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 360 to 375 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 0.0012207031)
Range
0 to 79 V
Unit
V

In testing for 2000 to 2020. Not supported for 2021 to 2026.

Throttle position sensor voltage #2 K5_THROTTLE_POSITION_SENSOR_VOLTAGE__2

  • Request21 14
  • Service 21PID 14
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 0.0012207031)
Range
0 to 79 V
Unit
V

In testing for 2000 to 2020. Not supported for 2021 to 2026.

Waste gate voltage K5_WASTE_GATE_V

  • Request21 21
  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 392 to 407 of the reply, 16 bits.

Formula
(val × 0.000152588)
Range
0 to 9.99 V
Unit
V

In testing for 2000 to 2020.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.