Kia K5

Engine parameters

The Kia K5 has 222 engine parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Automatic transmission fluid temperature K5_ATF_TConfirmed

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 01 A0
  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2000 to 2020, 2024

Example reply from a 2026 Kia K5.

Bits 104 to 111 of the reply, 8 bits.

0x47 = 71 → (71 − 40) = 31 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2000 to 2020. Not supported for 2024.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Absolute load value LOAD_ABSSAE J1979Confirmed

  • Request01 43
  • Service 01PID 43
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 25700 %
Unit
%

Confirmed for 2023 to 2025. Supported for 2015, 2021, 2026.

Actual engine torque TQ_ACTSAE J1979Confirmed

  • Request01 62
  • Service 01PID 62
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 125)
Range
-125 to 130 %
Unit
%

Confirmed for 2023. Supported for 2024.

Air conditioning pressure K5_AC_PConfirmed

  • Request22 E0 14
  • Service 22DID E014
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2024, 2026

Example reply from a 2025 Kia K5.

Bits 112 to 119 of the reply, 8 bits.

0x47 = 71 → (71 × 13.79) = 979.09 kPa

Formula
(val × 13.79)
Range
0 to 3516.45 kPa
Unit
kPa

Confirmed for 2025. In testing for 2000 to 2024, 2026.

Air flow rate from mass air flow sensor MAFSAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Request01 10
  • Service 01PID 10
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 g/s
Unit
g/s

Confirmed for 2021 to 2023, 2025 to 2026.

Automatic transmission fluid temperature K5_ATF_TConfirmed

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 01 A0
  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2000 to 2020, 2024

Example reply from a 2026 Kia K5.

Bits 104 to 111 of the reply, 8 bits.

0x47 = 71 → (71 − 40) = 31 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2000 to 2020. Not supported for 2024.

Automatic transmission fluid temperature K5_ATF_T_7E1

Pelican can show this parameter as the transmission fluid temperature.

  • Request21 A0
  • Service 21PID A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2000 to 2020. Not supported for 2022 to 2023, 2025.

Barometric pressure BAROSAE J1979Confirmed

Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.

  • Request01 33
  • Service 01PID 33
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2023. Supported for 2015, 2021 to 2022, 2025 to 2026.

Barometric pressure K5_BAROMETRIC_PRESSURE

  • Request21 13
  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 312 to 319 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127.5 kPa
Unit
kPa

In testing for 2000 to 2020. Not supported for 2021, 2023 to 2026.

Boost pressure K5_BOOST_P

  • Request22 ED 01
  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 200 to 207 of the reply, 8 bits.

Formula
(val × 1372549 ÷ 100000)
Range
0 to 3499.9999
Unit
Raw value

In testing for 2000 to 2024, 2026. Not supported for 2025.

Boost pressure upstream K5_BOOST_P_UP

  • Request22 E0 03
  • Service 22DID E003
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2024, 2026

Bits 280 to 295 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 39 ÷ 500)
Range
0 to 5111
Unit
Raw value

In testing for 2000 to 2024, 2026. Supported for 2025.

Boost pressure upstream, desired K5_BOOST_P_UP_DES

  • Request22 E0 03
  • Service 22DID E003
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2024, 2026

Bits 312 to 327 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 39 ÷ 500)
Range
0 to 5111
Unit
Raw value

In testing for 2000 to 2024, 2026. Supported for 2025.

Boost regulator duty K5_BOOST_REGULATOR_DUTY

  • Request22 ED 01
  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 208 to 215 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 2000 to 2024, 2026. Not supported for 2025.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Request01 04
  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2021 to 2023, 2025 to 2026. Supported for 2015, 2024.

Calculated oil temperature K5_CALC_OIL_TConfirmed

  • Request22 E0 11
  • Service 22DID E011
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2000 to 2024, 2026

Example reply from a 2025 Kia K5.

Bits 304 to 311 of the reply, 8 bits.

0x00 = 0 → (0 − 40) = -40 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2025. In testing for 2000 to 2024, 2026.

Catalyst damaging misfires total all cylinders K5_CATALYST_DAMAGING_MISFIRES_TOTAL_ALL_CYLINDERS

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 448 to 463 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2000 to 2024, 2026. Not supported for 2025.

Catalyst damaging misfires total all cylinders K5_CATDMG_MIS_TOT_ALL

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 400 to 415 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2000 to 2020.

Catalyst damaging misfires total, cylinder 1 K5_CATALYST_DAMAGING_MISFIRES_TOTAL_C1

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 304 to 319 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2000 to 2024, 2026. Not supported for 2025.

Catalyst damaging misfires total, cylinder 1 K5_CATDMG_MIS_TOT_1

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2000 to 2020.

Catalyst damaging misfires total, cylinder 2 K5_CATALYST_DAMAGING_MISFIRES_TOTAL_C2

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 320 to 335 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2000 to 2024, 2026. Not supported for 2025.

Catalyst damaging misfires total, cylinder 2 K5_CATDMG_MIS_TOT_2

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 272 to 287 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2000 to 2020.

Catalyst damaging misfires total, cylinder 3 K5_CATALYST_DAMAGING_MISFIRES_TOTAL_C3

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 336 to 351 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2000 to 2024, 2026. Not supported for 2025.

Catalyst damaging misfires total, cylinder 3 K5_CATDMG_MIS_TOT_3

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 288 to 303 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2000 to 2020.

Catalyst damaging misfires total, cylinder 4 K5_CATALYST_DAMAGING_MISFIRES_TOTAL_C4

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 352 to 367 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2000 to 2024, 2026. Not supported for 2025.

Catalyst damaging misfires total, cylinder 4 K5_CATDMG_MIS_TOT_4

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 304 to 319 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2000 to 2020.

Catalyst damaging misfires total, cylinder 5 K5_CATDMG_MIS_TOT_5

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 320 to 335 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2000 to 2020.

Catalyst damaging misfires total, cylinder 6 K5_CATDMG_MIS_TOT_6

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 336 to 351 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2000 to 2020.

Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed

  • Request01 3C
  • Service 01PID 3C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2023. Supported for 2015, 2021 to 2022, 2025 to 2026.

Commanded EGR EGR_PCTSAE J1979Confirmed

  • Request01 2C
  • Service 01PID 2C
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2023. Supported for 2021 to 2022, 2025 to 2026.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Fuel systems that utilize conventional oxygen sensor display the inverse of the commanded open loop equivalence ratio (also known as lambda) while the fuel control system is in open loop. Will indicate 1.000 while in closed-loop fuel.

Pelican can show this parameter as the commanded lambda.

  • Request01 44
  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 2 ÷ 65535)
Range
0 to 1.99
Unit
Number

Confirmed for 2021 to 2026. Supported for 2015.

Commanded evaporative purge EVAP_PCTSAE J1979Confirmed

  • Request01 2E
  • Service 01PID 2E
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2023. Supported for 2021 to 2022, 2025 to 2026.

Commanded throttle actuator K5_COMMANDED_THROTTLE_ACTUATOR

  • Request21 14
  • Service 21PID 14
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val × 0.390625)
Range
0 to 99.6 %
Unit
%

In testing for 2000 to 2020. Not supported for 2021 to 2026.

Commanded throttle actuator control TAC_PCTSAE J1979Confirmed

  • Request01 4C
  • Service 01PID 4C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2023. Supported for 2015, 2024.

Coolant fan PWM K5_CLT_FAN_PWMConfirmed

  • Request22 E0 14
  • Service 22DID E014
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2024, 2026

Example reply from a 2025 Kia K5.

Bits 88 to 103 of the reply, 16 bits.

0x4D68 = 19816 → (19816 × 15.21 ÷ 10000) = 30.140136 %

Formula
(val × 15.21 ÷ 10000)
Range
0 to 99.67 %
Unit
%

Confirmed for 2025. In testing for 2000 to 2024, 2026.

Coolant temperature K5_HVAC_COOLANT_TConfirmed

  • Request22 01 02
  • Service 22DID 0102
  • Module7B3 → 7BB
  • Every1 s
  • Testing for 2000 to 2024, 2026

Example reply from a 2025 Kia K5.

Bits 32 to 39 of the reply, 8 bits.

0xFF = 255 → (255 ÷ 2 − 40) = 87.5 °C

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

Confirmed for 2025. In testing for 2000 to 2024, 2026.

Coolant) K5_COOLANT_FAN_PWM

  • Request21 14
  • Service 21PID 14
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2000 to 2020. Not supported for 2021 to 2026.

Cylinder 1 injection time, 1st pulse K5_CYL_1_INJ_TIME_1ST

  • Request21 23
  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 264 to 279 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

In testing for 2000 to 2020.

Cylinder 1 injection time, 2nd pulse K5_CYL_1_INJ_TIME_2ND

  • Request21 23
  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 200 to 215 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

In testing for 2000 to 2020.

Cylinder 2 injection time, 1st pulse K5_CYL_2_INJ_TIME_1ST

  • Request21 23
  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 280 to 295 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

In testing for 2000 to 2020.

Cylinder 2 injection time, 2nd pulse K5_CYL_2_INJ_TIME_2ND

  • Request21 23
  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 216 to 231 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

In testing for 2000 to 2020.

Cylinder 3 injection time, 1st pulse K5_CYL_3_INJ_TIME_1ST

  • Request21 23
  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 296 to 311 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

In testing for 2000 to 2020.

Cylinder 3 injection time, 2nd pulse K5_CYL_3_INJ_TIME_2ND

  • Request21 23
  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 232 to 247 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

In testing for 2000 to 2020.

Cylinder 4 injection time, 1st pulse K5_CYL_4_INJ_TIME_1ST

  • Request21 23
  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 312 to 327 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

In testing for 2000 to 2020.

Cylinder 4 injection time, 2nd pulse K5_CYL_4_INJ_TIME_2ND

  • Request21 23
  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 248 to 263 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

In testing for 2000 to 2020.

Diesel particulate filter load, from model K5_DPF_LOAD_MODEL

  • Request22 ED 03
  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 296 to 303 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2000 to 2024, 2026. Not supported for 2025.

Diesel particulate filter regen demand counter K5_DPF_REGEN_DEMAND_CNT

  • Request22 ED 03
  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 432 to 439 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2000 to 2024, 2026. Not supported for 2025.

Diesel particulate filter regen success state K5_DPF_REGEN_SUCCESS_ST

  • Request22 ED 03
  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 407 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2000 to 2024, 2026. Not supported for 2025.

Direct injection time 1 K5_DI_TIME_1

  • Request21 0B
  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 100 ÷ 13107)
Range
0 to 500 ms
Unit
ms

In testing for 2000 to 2020.

Direct injection time 2 K5_DI_TIME_2

  • Request21 0B
  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 100 ÷ 13107)
Range
0 to 500 ms
Unit
ms

In testing for 2000 to 2020.

Direct injection time 3 K5_DI_TIME_3

  • Request21 0B
  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 100 ÷ 13107)
Range
0 to 500 ms
Unit
ms

In testing for 2000 to 2020.

Direct injection time 4 K5_DI_TIME_4

  • Request21 0B
  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 100 ÷ 13107)
Range
0 to 500 ms
Unit
ms

In testing for 2000 to 2020.

Direct injection time 5 K5_DI_TIME_5

  • Request21 0B
  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 100 ÷ 13107)
Range
0 to 500 ms
Unit
ms

In testing for 2000 to 2020.

Direct injection time 6 K5_DI_TIME_6

  • Request21 0B
  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 127 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 100 ÷ 13107)
Range
0 to 500 ms
Unit
ms

In testing for 2000 to 2020.

Dual-clutch transmission clutch 1, pressure sensor a K5_DUAL_CLU_TRANS_CLU_1_PConfirmed

  • Request22 01 A5
  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing for 2000 to 2024, 2026

Bits 192 to 207 of the reply, 16 bits.

Formula
(val × 19.53 ÷ 10000)
Range
0 to 127 bar
Unit
bar

Confirmed for 2025. In testing for 2000 to 2024, 2026.

Dual-clutch transmission clutch 2, pressure sensor b K5_DUAL_CLU_TRANS_CLU_2_P_BConfirmed

  • Request22 01 A5
  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing for 2000 to 2024, 2026

Example reply from a 2025 Kia K5.

Bits 208 to 223 of the reply, 16 bits.

0x156C = 5484 → (5484 × 19.53 ÷ 10000) = 10.710252 bar

Formula
(val × 19.53 ÷ 10000)
Range
0 to 127 bar
Unit
bar

Confirmed for 2025. In testing for 2000 to 2024, 2026.

Dual-clutch transmission fluid temperature 1 K5_DUAL_CLU_ATF_T_1Confirmed

  • Request22 01 A5
  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing for 2000 to 2024, 2026

Example reply from a 2025 Kia K5.

Bits 48 to 55 of the reply, 8 bits.

0x45 = 69 → (69 − 40) = 29 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2025. In testing for 2000 to 2024, 2026.

Dual-clutch transmission fluid temperature 2 K5_DUAL_CLU_ATF_T_2Confirmed

  • Request22 01 A5
  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing for 2000 to 2024, 2026

Example reply from a 2025 Kia K5.

Bits 56 to 63 of the reply, 8 bits.

0x50 = 80 → (80 − 40) = 40 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2025. In testing for 2000 to 2024, 2026.

Dual-clutch transmission line pressure, sensor c K5_DUAL_CLU_TRANS_LINE_P_CConfirmed

  • Request22 01 A5
  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing for 2000 to 2024, 2026

Example reply from a 2025 Kia K5.

Bits 224 to 239 of the reply, 16 bits.

0x5ADE = 23262 → (23262 × 19.53 ÷ 10000) = 45.430686 bar

Formula
(val × 19.53 ÷ 10000)
Range
0 to 127 bar
Unit
bar

Confirmed for 2025. In testing for 2000 to 2024, 2026.

EGR error EGR_ERRSAE J1979Confirmed

  • Request01 2D
  • Service 01PID 2D
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.22 %
Unit
%

Confirmed for 2023. Supported for 2021 to 2022, 2025 to 2026.

Emission relevant misfires total all cylinders K5_EMIS_MIS_TOT_ALL

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 384 to 399 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2000 to 2020.

Emission relevant misfires total all cylinders K5_EMISSION_RELEVANT_MISFIRES_TOTAL_ALL_CYLINDERS

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 432 to 447 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2000 to 2024, 2026. Not supported for 2025.

Emission relevant misfires total, cylinder 1 K5_EMIS_MIS_TOT_1

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 128 to 143 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2000 to 2020.

Emission relevant misfires total, cylinder 1 K5_EMISSION_RELEVANT_MISFIRES_TOTAL_C1

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2000 to 2024, 2026. Not supported for 2025.

Emission relevant misfires total, cylinder 2 K5_EMIS_MIS_TOT_2

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 144 to 159 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2000 to 2020.

Emission relevant misfires total, cylinder 2 K5_EMISSION_RELEVANT_MISFIRES_TOTAL_C2

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2000 to 2024, 2026. Not supported for 2025.

Emission relevant misfires total, cylinder 3 K5_EMIS_MIS_TOT_3

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2000 to 2020.

Emission relevant misfires total, cylinder 3 K5_EMISSION_RELEVANT_MISFIRES_TOTAL_C3

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2000 to 2024, 2026. Not supported for 2025.

Emission relevant misfires total, cylinder 4 K5_EMIS_MIS_TOT_4

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2000 to 2020.

Emission relevant misfires total, cylinder 4 K5_EMISSION_RELEVANT_MISFIRES_TOTAL_C4

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2000 to 2024, 2026. Not supported for 2025.

Emission relevant misfires total, cylinder 5 K5_EMIS_MIS_TOT_5

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2000 to 2020.

Emission relevant misfires total, cylinder 6 K5_EMIS_MIS_TOT_6

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2000 to 2020.

Engine coolant temperature K5_ENGINE_COOLANT_T

Pelican can show this parameter as the engine coolant temperature.

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 200 to 207 of the reply, 8 bits.

Formula
(val × 0.75 − 48)
Range
-48 to 143.25 °C
Unit
°C

In testing for 2000 to 2020. Not supported for 2021 to 2026.

Engine coolant temperature 1 ECT_1SAE J1979Confirmed

  • Request01 67
  • Service 01PID 67
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 15 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023. Supported for 2024.

Engine coolant temperature 2 ECT_2SAE J1979Confirmed

  • Request01 67
  • Service 01PID 67
  • Module7E0 → 7E8
  • Every1 s

Bits 16 to 23 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023. Supported for 2024.

Engine Friction - Percent Torque TQ_FRSAE J1979Confirmed

  • Request01 8E
  • Service 01PID 8E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 125)
Range
-125 to 130 %
Unit
%

Confirmed for 2023. Supported for 2024.

Engine oil temperature K5_ENGINE_OIL_T

Pelican can show this parameter as the engine oil temperature.

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 272 to 279 of the reply, 8 bits.

Formula
(val × 0.75 − 48)
Range
-48 to 143.25 °C
Unit
°C

In testing for 2000 to 2020. Not supported for 2021 to 2026.

Engine oil temperature K5_EOTConfirmed

Pelican can show this parameter as the engine oil temperature.

  • Request22 E0 01
  • Service 22DID E001
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2020, 2024

Example reply from a 2026 Kia K5.

Bits 272 to 279 of the reply, 8 bits.

0x70 = 112 → (112 × 3 ÷ 4 − 48) = 36 °C

Formula
(val × 3 ÷ 4 − 48)
Range
-48 to 143 °C
Unit
°C

Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2000 to 2020. Not supported for 2024.

Engine oil temperature K5_EOT_7E0

Pelican can show this parameter as the engine oil temperature.

  • Request22 ED 07
  • Service 22DID ED07
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 152 to 159 of the reply, 8 bits.

Formula
(val × 0.7843 − 50)
Range
-50 to 149.9965 °C
Unit
°C

In testing for 2000 to 2024, 2026. Not supported for 2025.

Engine oil temperature K5_EOT_V2

Pelican can show this parameter as the engine oil temperature.

  • Request22 ED 02
  • Service 22DID ED02
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
(val − 4)
Range
-4 to 251 °C
Unit
°C

In testing for 2000 to 2020. Not supported for 2022 to 2023, 2025.

Engine reference torque TQ_REFSAE J1979Confirmed

  • Request01 63
  • Service 01PID 63
  • Module7E0 → 7E8
  • Every86400 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

Confirmed for 2023. Supported for 2024.

Engine RPM K5_ENGINE_RPM_TCM

Pelican can show this parameter as the engine speed.

  • Request21 A0
  • Service 21PID A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2000 to 2020. Not supported for 2022 to 2023, 2025.

Engine RPM RPMSAE J1979Confirmed

  • Request01 0C
  • Service 01PID 0C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383.75 rpm
Unit
rpm

Confirmed for 2023, 2025. Supported for 2015, 2021 to 2022, 2024, 2026.

Engine run time, total K5_ENG_RUN_TIME_TOT

  • Request21 0E
  • Service 21PID 0E
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 6)
Range
0 to 393209.9999 min
Unit
min

In testing for 2000 to 2020.

Evap system vapor pressure EVAP_VPSAE J1979Confirmed

The pressure signal is normally obtained from a sensor located in the fuel tank or a sensor in an evaporative system vapor line.

  • Request01 32
  • Service 01PID 32
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 4000)
Range
-8192 to 8191.75 kPa
Unit
kPa

Confirmed for 2023. Supported for 2021 to 2022, 2025 to 2026.

Exhaust camshaft position K5_EXH_CAM_POSConfirmed

  • Request22 E0 20
  • Service 22DID E020
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2024, 2026

Example reply from a 2025 Kia K5.

Bits 88 to 103 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

0xC100 = -16128 → (-16128 ÷ 128) = -126 °

Formula
(val ÷ 128)
Range
-256 to 255 °
Unit
°

Confirmed for 2025. In testing for 2000 to 2024, 2026.

Exhaust gas flow in the particulate filter K5_EXH_GAS_FLOW_PF

  • Request22 ED 03
  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 256 to 263 of the reply, 8 bits.

Formula
(val × 392157 ÷ 50)
Range
0 to 2000000.7 L
Unit
L

In testing for 2000 to 2024, 2026. Not supported for 2025.

Exhaust gas temperature K5_EXHAUST_GAS_T

  • Request21 03
  • Service 21PID 03
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 368 to 375 of the reply, 8 bits.

Formula
(val × 4.709803922 + 99)
Range
99 to 1300 °C
Unit
°C

In testing for 2000 to 2020. Not supported for 2021, 2023 to 2026.

Exhaust gas temperature at catalyst K5_EXH_GAS_T_CAT

  • Request22 ED 03
  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 272 to 279 of the reply, 8 bits.

Formula
(val × 471 ÷ 100 + 99)
Range
0 to 1300.05 °C
Unit
°C

In testing for 2000 to 2024, 2026. Not supported for 2025.

Fuel rail pressure FRPSAE J1979Confirmed

Fuel rail pressure at the engine when the reading is referenced to atmosphere (gage pressure).

  • Request01 23
  • Service 01PID 23
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 10)
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2023, 2025. Supported for 2021 to 2022, 2026.

Gasoline direct injection time bank a, 1 K5_GDI_IT_A1

  • Request22 E0 05
  • Service 22DID E005
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2024, 2026

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
0 to 6553.5 ms
Unit
ms

In testing for 2000 to 2024, 2026. Supported for 2025.

Gasoline direct injection time bank a, 2 K5_GDI_IT_A2

  • Request22 E0 05
  • Service 22DID E005
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2024, 2026

Bits 240 to 255 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
0 to 6553.5 ms
Unit
ms

In testing for 2000 to 2024, 2026. Supported for 2025.

Gasoline direct injection time bank a, 3 K5_GDI_IT_A3

  • Request22 E0 05
  • Service 22DID E005
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2024, 2026

Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
0 to 6553.5 ms
Unit
ms

In testing for 2000 to 2024, 2026. Supported for 2025.

Gasoline direct injection time bank a, 4 K5_GDI_IT_A4

  • Request22 E0 05
  • Service 22DID E005
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2024, 2026

Bits 272 to 287 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
0 to 6553.5 ms
Unit
ms

In testing for 2000 to 2024, 2026. Supported for 2025.

Gasoline direct injection time bank b, 1 K5_GDI_IT_B1

  • Request22 E0 05
  • Service 22DID E005
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2024, 2026

Bits 352 to 367 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
0 to 6553.5 ms
Unit
ms

In testing for 2000 to 2024, 2026. Supported for 2025.

Gasoline direct injection time bank b, 2 K5_GDI_IT_B2

  • Request22 E0 05
  • Service 22DID E005
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2024, 2026

Bits 368 to 383 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
0 to 6553.5 ms
Unit
ms

In testing for 2000 to 2024, 2026. Supported for 2025.

Gasoline direct injection time bank b, 3 K5_GDI_IT_B3

  • Request22 E0 05
  • Service 22DID E005
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2024, 2026

Bits 384 to 399 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
0 to 6553.5 ms
Unit
ms

In testing for 2000 to 2024, 2026. Supported for 2025.

Gasoline direct injection time bank b, 4 K5_GDI_IT_B4

  • Request22 E0 05
  • Service 22DID E005
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2024, 2026

Bits 400 to 415 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
0 to 6553.5 ms
Unit
ms

In testing for 2000 to 2024, 2026. Supported for 2025.

Glow relay duty K5_GLOW_RELAY_DUTY

  • Request22 ED 01
  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
(val × 2451 ÷ 6250)
Range
0 to 100 %
Unit
%

In testing for 2000 to 2024, 2026. Not supported for 2025.

Idle control mode K5_IDLE_CONTROL_MODE

  • Request21 00
  • Service 21PID 00
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2000 to 2020.

Injection duration cylinder 1 K5_INJ_DUR_1Confirmed

  • Request22 E0 02
  • Service 22DID E002
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2000 to 2020, 2024

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 1220.7)
Range
0 to 53.6864 s
Unit
s

Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2000 to 2020. Not supported for 2024.

Injection duration cylinder 2 K5_INJ_DUR_2Confirmed

  • Request22 E0 02
  • Service 22DID E002
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2000 to 2020, 2024

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 1220.7)
Range
0 to 53.6864 s
Unit
s

Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2000 to 2020. Not supported for 2024.

Injection duration cylinder 3 K5_INJ_DUR_3Confirmed

  • Request22 E0 02
  • Service 22DID E002
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2000 to 2020, 2024

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 1220.7)
Range
0 to 53.6864 s
Unit
s

Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2000 to 2020. Not supported for 2024.

Injection duration cylinder 4 K5_INJ_DUR_4Confirmed

  • Request22 E0 02
  • Service 22DID E002
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2000 to 2020, 2024

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 1220.7)
Range
0 to 53.6864 s
Unit
s

Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2000 to 2020. Not supported for 2024.

Injection impulse 1, cylinder 1 K5_INJ_IMPULSE_1_CYL_1Confirmed

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2024, 2026

Example reply from a 2025 Kia K5.

Bits 200 to 215 of the reply, 16 bits. The bytes are in little-endian order.

0x0182 = 386 → (386 ÷ 250) = 1.544 ms

Formula
(val ÷ 250)
Range
0 to 262.14 ms
Unit
ms

Confirmed for 2025. In testing for 2000 to 2024, 2026.

Injection impulse 1, cylinder 2 K5_INJ_IMPULSE_1_CYL_2Confirmed

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2024, 2026

Example reply from a 2025 Kia K5.

Bits 216 to 231 of the reply, 16 bits. The bytes are in little-endian order.

0x0185 = 389 → (389 ÷ 250) = 1.556 ms

Formula
(val ÷ 250)
Range
0 to 262.14 ms
Unit
ms

Confirmed for 2025. In testing for 2000 to 2024, 2026.

Injection impulse 1, cylinder 3 K5_INJ_IMPULSE_1_CYL_3Confirmed

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2024, 2026

Example reply from a 2025 Kia K5.

Bits 232 to 247 of the reply, 16 bits. The bytes are in little-endian order.

0x0185 = 389 → (389 ÷ 250) = 1.556 ms

Formula
(val ÷ 250)
Range
0 to 262.14 ms
Unit
ms

Confirmed for 2025. In testing for 2000 to 2024, 2026.

Injection impulse 1, cylinder 4 K5_INJ_IMPULSE_1_CYL_4Confirmed

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2024, 2026

Example reply from a 2025 Kia K5.

Bits 248 to 263 of the reply, 16 bits. The bytes are in little-endian order.

0x0177 = 375 → (375 ÷ 250) = 1.5 ms

Formula
(val ÷ 250)
Range
0 to 262.14 ms
Unit
ms

Confirmed for 2025. In testing for 2000 to 2024, 2026.

Injection impulse 2, cylinder 1 K5_INJ_IMPULSE_2_CYL_1Confirmed

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2024, 2026

Example reply from a 2025 Kia K5.

Bits 264 to 279 of the reply, 16 bits. The bytes are in little-endian order.

0x0000 = 0 → (0 ÷ 250) = 0 ms

Formula
(val ÷ 250)
Range
0 to 262.14 ms
Unit
ms

Confirmed for 2025. In testing for 2000 to 2024, 2026.

Injection impulse 2, cylinder 2 K5_INJ_IMPULSE_2_CYL_2Confirmed

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2024, 2026

Example reply from a 2025 Kia K5.

Bits 280 to 295 of the reply, 16 bits. The bytes are in little-endian order.

0x0000 = 0 → (0 ÷ 250) = 0 ms

Formula
(val ÷ 250)
Range
0 to 262.14 ms
Unit
ms

Confirmed for 2025. In testing for 2000 to 2024, 2026.

Injection impulse 2, cylinder 3 K5_INJ_IMPULSE_2_CYL_3Confirmed

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2024, 2026

Example reply from a 2025 Kia K5.

Bits 296 to 311 of the reply, 16 bits. The bytes are in little-endian order.

0x0000 = 0 → (0 ÷ 250) = 0 ms

Formula
(val ÷ 250)
Range
0 to 262.14 ms
Unit
ms

Confirmed for 2025. In testing for 2000 to 2024, 2026.

Injection impulse 2, cylinder 4 K5_INJ_IMPULSE_2_CYL_4Confirmed

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2024, 2026

Example reply from a 2025 Kia K5.

Bits 312 to 327 of the reply, 16 bits. The bytes are in little-endian order.

0x0000 = 0 → (0 ÷ 250) = 0 ms

Formula
(val ÷ 250)
Range
0 to 262.14 ms
Unit
ms

Confirmed for 2025. In testing for 2000 to 2024, 2026.

Injection impulse 3, cylinder 1 K5_INJ_IMPULSE_3_CYL_1Confirmed

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2024, 2026

Example reply from a 2025 Kia K5.

Bits 328 to 343 of the reply, 16 bits. The bytes are in little-endian order.

0x0000 = 0 → (0 ÷ 25) = 0 ms

Formula
(val ÷ 25)
Range
0 to 2621.4 ms
Unit
ms

Confirmed for 2025. In testing for 2000 to 2024, 2026.

Injection impulse 3, cylinder 2 K5_INJ_IMPULSE_3_CYL_2Confirmed

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2024, 2026

Example reply from a 2025 Kia K5.

Bits 344 to 359 of the reply, 16 bits. The bytes are in little-endian order.

0x0000 = 0 → (0 ÷ 25) = 0 ms

Formula
(val ÷ 25)
Range
0 to 2621.4 ms
Unit
ms

Confirmed for 2025. In testing for 2000 to 2024, 2026.

Injection impulse 3, cylinder 3 K5_INJ_IMPULSE_3_CYL_3Confirmed

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2024, 2026

Example reply from a 2025 Kia K5.

Bits 360 to 375 of the reply, 16 bits. The bytes are in little-endian order.

0x0000 = 0 → (0 ÷ 25) = 0 ms

Formula
(val ÷ 25)
Range
0 to 2621.4 ms
Unit
ms

Confirmed for 2025. In testing for 2000 to 2024, 2026.

Injection impulse 3, cylinder 4 K5_INJ_IMPULSE_3_CYL_4Confirmed

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2024, 2026

Example reply from a 2025 Kia K5.

Bits 376 to 391 of the reply, 16 bits. The bytes are in little-endian order.

0x0000 = 0 → (0 ÷ 25) = 0 ms

Formula
(val ÷ 25)
Range
0 to 2621.4 ms
Unit
ms

Confirmed for 2025. In testing for 2000 to 2024, 2026.

Intake air temperature IATSAE J1979Confirmed

  • Request01 0F
  • Service 01PID 0F
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023. Supported for 2015, 2021 to 2022, 2025 to 2026.

Intake air temperature K5_EITConfirmed

  • Request22 E0 01
  • Service 22DID E001
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2020, 2024

Example reply from a 2026 Kia K5.

Bits 264 to 271 of the reply, 8 bits.

0x5C = 92 → (92 × 3 ÷ 4 − 48) = 21 °C

Formula
(val × 3 ÷ 4 − 48)
Range
-48 to 143 °C
Unit
°C

Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2000 to 2020. Not supported for 2024.

Intake air temperature K5_INTAKE_AIR_T

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 264 to 271 of the reply, 8 bits.

Formula
(val × 0.75 − 48)
Range
-48 to 143.25 °C
Unit
°C

In testing for 2000 to 2020. Not supported for 2021 to 2026.

Intake camshaft position K5_INT_CAM_POSConfirmed

  • Request22 E0 20
  • Service 22DID E020
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2024, 2026

Example reply from a 2025 Kia K5.

Bits 72 to 87 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

0x4062 = 16482 → (16482 ÷ 128) = 128.765625 °

Formula
(val ÷ 128)
Range
-256 to 255 °
Unit
°

Confirmed for 2025. In testing for 2000 to 2024, 2026.

Intake manifold absolute pressure MAPSAE J1979Confirmed

  • Request01 0B
  • Service 01PID 0B
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2023. Supported for 2015, 2021 to 2022, 2025 to 2026.

Inverter temperature K5_HVAC_INVERTER_TConfirmed

  • Request22 01 02
  • Service 22DID 0102
  • Module7B3 → 7BB
  • Every1 s
  • Testing for 2000 to 2024, 2026

Example reply from a 2025 Kia K5.

Bits 96 to 103 of the reply, 8 bits.

0xFF = 255 → (255 ÷ 2 − 40) = 87.5 °C

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

Confirmed for 2025. In testing for 2000 to 2024, 2026.

Knock detected K5_KNOCK_DETECTED

  • Request21 00
  • Service 21PID 00
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 200 to 207 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2000 to 2020.

Knock learn cylinder 1 K5_KNOCK_LEARN_1Confirmed

  • Request22 E0 0A
  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2020, 2024

Example reply from a 2023 Kia K5.

Bits 160 to 167 of the reply, 8 bits. The value is signed.

0x00 = 0 → (0 ÷ 5) = 0 °

Formula
(val ÷ 5)
Range
-25.6 to 25.4 °
Unit
°

Confirmed for 2021 to 2023. In testing for 2000 to 2020. Supported for 2025 to 2026. Not supported for 2024.

Knock learn cylinder 2 K5_KNOCK_LEARN_2Confirmed

  • Request22 E0 0A
  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2020, 2024

Example reply from a 2023 Kia K5.

Bits 168 to 175 of the reply, 8 bits. The value is signed.

0x00 = 0 → (0 ÷ 5) = 0 °

Formula
(val ÷ 5)
Range
-25.6 to 25.4 °
Unit
°

Confirmed for 2021 to 2023. In testing for 2000 to 2020. Supported for 2025 to 2026. Not supported for 2024.

Knock learn cylinder 3 K5_KNOCK_LEARN_3Confirmed

  • Request22 E0 0A
  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2020, 2024

Example reply from a 2023 Kia K5.

Bits 176 to 183 of the reply, 8 bits. The value is signed.

0x00 = 0 → (0 ÷ 5) = 0 °

Formula
(val ÷ 5)
Range
-25.6 to 25.4 °
Unit
°

Confirmed for 2021 to 2023. In testing for 2000 to 2020. Supported for 2025 to 2026. Not supported for 2024.

Knock learn cylinder 4 K5_KNOCK_LEARN_4Confirmed

  • Request22 E0 0A
  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2020, 2024

Example reply from a 2023 Kia K5.

Bits 184 to 191 of the reply, 8 bits. The value is signed.

0x00 = 0 → (0 ÷ 5) = 0 °

Formula
(val ÷ 5)
Range
-25.6 to 25.4 °
Unit
°

Confirmed for 2021 to 2023. In testing for 2000 to 2020. Supported for 2025 to 2026. Not supported for 2024.

Knock retard cylinder 1 K5_KNOCK_RETARD_1_E00AConfirmed

  • Request22 E0 0A
  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2020, 2024

Example reply from a 2026 Kia K5.

Bits 96 to 103 of the reply, 8 bits. The value is signed.

0xB8 = -72 → (-72 ÷ 5) = -14.4 °

Formula
(val ÷ 5)
Range
-25.6 to 25.4 °
Unit
°

Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2000 to 2020. Not supported for 2024.

Knock retard cylinder 1 K5_KNOCK_RETARD_CYL_1

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
(val × 3 ÷ 4 − 191.25)
Range
-191.25 to 0 °
Unit
°

In testing for 2000 to 2020. Not supported for 2021, 2023 to 2026.

Knock retard cylinder 1, alternate K5_KNOCK_RETARD_1_E019Confirmed

  • Request22 E0 19
  • Service 22DID E019
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2024, 2026

Example reply from a 2025 Kia K5.

Bits 168 to 175 of the reply, 8 bits.

0x00 = 0 → (0 × 0.75 − 191.25) = -191.25 °

Formula
(val × 0.75 − 191.25)
Range
-191.25 to 0 °
Unit
°

Confirmed for 2025. In testing for 2000 to 2024, 2026.

Knock retard cylinder 1, alternate K5_KNOCK_RETARD_CYL_1_ALT

  • Request21 0A
  • Service 21PID 0A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
(val ÷ 1.333333333)
Range
0 to 191.25 °
Unit
°

In testing for 2000 to 2020.

Knock retard cylinder 2 K5_KNOCK_RETARD_2_E00AConfirmed

  • Request22 E0 0A
  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2020, 2024

Example reply from a 2026 Kia K5.

Bits 104 to 111 of the reply, 8 bits. The value is signed.

0x00 = 0 → (0 ÷ 5) = 0 °

Formula
(val ÷ 5)
Range
-25.6 to 25.4 °
Unit
°

Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2000 to 2020. Not supported for 2024.

Knock retard cylinder 2 K5_KNOCK_RETARD_CYL_2

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
(val × 3 ÷ 4 − 191.25)
Range
-191.25 to 0 °
Unit
°

In testing for 2000 to 2020. Not supported for 2021, 2023 to 2026.

Knock retard cylinder 2, alternate K5_KNOCK_RETARD_2_E019Confirmed

  • Request22 E0 19
  • Service 22DID E019
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2024, 2026

Example reply from a 2025 Kia K5.

Bits 176 to 183 of the reply, 8 bits.

0x00 = 0 → (0 × 0.75 − 191.25) = -191.25 °

Formula
(val × 0.75 − 191.25)
Range
-191.25 to 0 °
Unit
°

Confirmed for 2025. In testing for 2000 to 2024, 2026.

Knock retard cylinder 2, alternate K5_KNOCK_RETARD_CYL_2_ALT

  • Request21 0A
  • Service 21PID 0A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
(val ÷ 1.333333333)
Range
0 to 191.25 °
Unit
°

In testing for 2000 to 2020.

Knock retard cylinder 3 K5_KNOCK_RETARD_3_E00AConfirmed

  • Request22 E0 0A
  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2020, 2024

Example reply from a 2026 Kia K5.

Bits 112 to 119 of the reply, 8 bits. The value is signed.

0x00 = 0 → (0 ÷ 5) = 0 °

Formula
(val ÷ 5)
Range
-25.6 to 25.4 °
Unit
°

Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2000 to 2020. Not supported for 2024.

Knock retard cylinder 3 K5_KNOCK_RETARD_CYL_3

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
(val × 3 ÷ 4 − 191.25)
Range
-191.25 to 0 °
Unit
°

In testing for 2000 to 2020. Not supported for 2021, 2023 to 2026.

Knock retard cylinder 3, alternate K5_KNOCK_RETARD_3_E019Confirmed

  • Request22 E0 19
  • Service 22DID E019
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2024, 2026

Example reply from a 2025 Kia K5.

Bits 184 to 191 of the reply, 8 bits.

0x00 = 0 → (0 × 0.75 − 191.25) = -191.25 °

Formula
(val × 0.75 − 191.25)
Range
-191.25 to 0 °
Unit
°

Confirmed for 2025. In testing for 2000 to 2024, 2026.

Knock retard cylinder 3, alternate K5_KNOCK_RETARD_CYL_3_ALT

  • Request21 0A
  • Service 21PID 0A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
(val ÷ 1.333333333)
Range
0 to 191.25 °
Unit
°

In testing for 2000 to 2020.

Knock retard cylinder 4 K5_KNOCK_RETARD_4_E00AConfirmed

  • Request22 E0 0A
  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2020, 2024

Example reply from a 2026 Kia K5.

Bits 120 to 127 of the reply, 8 bits. The value is signed.

0x3F = 63 → (63 ÷ 5) = 12.6 °

Formula
(val ÷ 5)
Range
-25.6 to 25.4 °
Unit
°

Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2000 to 2020. Not supported for 2024.

Knock retard cylinder 4 K5_KNOCK_RETARD_CYL_4

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
(val × 3 ÷ 4 − 191.25)
Range
-191.25 to 0 °
Unit
°

In testing for 2000 to 2020. Not supported for 2021, 2023 to 2026.

Knock retard cylinder 4, alternate K5_KNOCK_RETARD_4_E019Confirmed

  • Request22 E0 19
  • Service 22DID E019
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2024, 2026

Example reply from a 2025 Kia K5.

Bits 192 to 199 of the reply, 8 bits.

0x00 = 0 → (0 × 0.75 − 191.25) = -191.25 °

Formula
(val × 0.75 − 191.25)
Range
-191.25 to 0 °
Unit
°

Confirmed for 2025. In testing for 2000 to 2024, 2026.

Knock retard cylinder 4, alternate K5_KNOCK_RETARD_CYL_4_ALT

  • Request21 0A
  • Service 21PID 0A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
(val ÷ 1.333333333)
Range
0 to 191.25 °
Unit
°

In testing for 2000 to 2020.

Long term fuel trim (bank 1) LONGFT1SAE J1979Confirmed

  • Request01 07
  • Service 01PID 07
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.2 %
Unit
%

Confirmed for 2023, 2025. Supported for 2015, 2021 to 2022, 2026.

Long term secondary O2 sensor fuel trim (bank 1) LGSO2FT1SAE J1979Confirmed

  • Request01 56
  • Service 01PID 56
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.22 %
Unit
%

Confirmed for 2023, 2025. Supported for 2024.

Main injection volume K5_MAIN_INJECTION_QTY

  • Request21 07
  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
(val × 0.392156863)
Range
0 to 100 L
Unit
L

In testing for 2000 to 2020.

Mass air flow rate K5_MAF_RATEConfirmed

  • Request22 E0 10
  • Service 22DID E010
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2024, 2026

Example reply from a 2025 Kia K5.

Bits 208 to 215 of the reply, 8 bits. The bytes are in little-endian order.

0x9E = 158 → (158 × 0.04239) = 6.69762

Formula
(val × 0.04239)
Range
0 to 10.8
Unit
Raw value

Confirmed for 2025. In testing for 2000 to 2024, 2026.

Misfires current total K5_MIS_CURRENT_TOT

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 584 to 591 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2000 to 2020.

Misfires current, cylinder 1 K5_MIS_CURRENT_1

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 536 to 543 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2000 to 2020.

Misfires current, cylinder 2 K5_MIS_CURRENT_2

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 544 to 551 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2000 to 2020.

Misfires current, cylinder 3 K5_MIS_CURRENT_3

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 552 to 559 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2000 to 2020.

Misfires current, cylinder 4 K5_MIS_CURRENT_4

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 560 to 567 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2000 to 2020.

Misfires current, cylinder 5 K5_MIS_CURRENT_5

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 568 to 575 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2000 to 2020.

Misfires current, cylinder 6 K5_MIS_CURRENT_6

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 576 to 583 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2000 to 2020.

Misfires harmful for catalyst, cylinder 1 K5_MIS_HARMFUL_CAT_1Confirmed

  • Request22 E0 1D
  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2024, 2026

Example reply from a 2025 Kia K5.

Bits 160 to 175 of the reply, 16 bits. The bytes are in little-endian order.

0x0000 = 0 → 0

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2025. In testing for 2000 to 2024, 2026.

Misfires harmful for catalyst, cylinder 2 K5_MIS_HARMFUL_CAT_2Confirmed

  • Request22 E0 1D
  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2024, 2026

Example reply from a 2025 Kia K5.

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

0x0000 = 0 → 0

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2025. In testing for 2000 to 2024, 2026.

Misfires harmful for catalyst, cylinder 3 K5_MIS_HARMFUL_CAT_3Confirmed

  • Request22 E0 1D
  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2024, 2026

Example reply from a 2025 Kia K5.

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

0x0000 = 0 → 0

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2025. In testing for 2000 to 2024, 2026.

Misfires harmful for catalyst, cylinder 4 K5_MIS_HARMFUL_CAT_4Confirmed

  • Request22 E0 1D
  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2024, 2026

Example reply from a 2025 Kia K5.

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

0x0000 = 0 → 0

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2025. In testing for 2000 to 2024, 2026.

Misfires, current, cylinder 1 K5_MISFIRES_C1_CUR

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2000 to 2024, 2026. Not supported for 2025.

Misfires, current, cylinder 2 K5_MISFIRES_C2_CUR

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2000 to 2024, 2026. Not supported for 2025.

Misfires, current, cylinder 3 K5_MISFIRES_C3_CUR

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2000 to 2024, 2026. Not supported for 2025.

Misfires, current, cylinder 4 K5_MISFIRES_C4_CUR

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2000 to 2024, 2026. Not supported for 2025.

Misfires, cylinder 1 K5_MIS_1_7E0Confirmed

  • Request22 E0 1D
  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2024, 2026

Example reply from a 2025 Kia K5.

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

0x0000 = 0 → 0

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2025. In testing for 2000 to 2024, 2026.

Misfires, cylinder 2 K5_MIS_2_7E0Confirmed

  • Request22 E0 1D
  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2024, 2026

Example reply from a 2025 Kia K5.

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

0x0000 = 0 → 0

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2025. In testing for 2000 to 2024, 2026.

Misfires, cylinder 3 K5_MIS_3_7E0Confirmed

  • Request22 E0 1D
  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2024, 2026

Example reply from a 2025 Kia K5.

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

0x0000 = 0 → 0

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2025. In testing for 2000 to 2024, 2026.

Misfires, cylinder 4 K5_MIS_4_7E0Confirmed

  • Request22 E0 1D
  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2024, 2026

Example reply from a 2025 Kia K5.

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

0x0000 = 0 → 0

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2025. In testing for 2000 to 2024, 2026.

NOx trap outlet pressure K5_NOX_TRAP_OUTLET_P

  • Request22 ED 03
  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 288 to 295 of the reply, 8 bits.

Formula
(val × 3212451 ÷ 25000)
Range
0 to 32767.0002
Unit
Raw value

In testing for 2000 to 2024, 2026. Not supported for 2025.

Output speed K5_OUTPUT_SPEED_7E1

  • Request21 A0
  • Service 21PID A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 88 to 103 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2000 to 2020. Not supported for 2022 to 2023, 2025.

Overheat protection, active K5_OVERHEAT_PROTECTIONConfirmed

  • Request22 E0 14
  • Service 22DID E014
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2024, 2026

Example reply from a 2025 Kia K5.

Bit 132 of the reply.

0b0 = 0 → 0

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2025. In testing for 2000 to 2024, 2026.

Pilot injection volume K5_PILOT_INJECTION_QTY

  • Request21 07
  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
val
Range
0 to 65535 L
Unit
L

In testing for 2000 to 2020.

Post injection volume K5_POST_INJECTION_QTY

  • Request21 07
  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
val
Range
0 to 65535 L
Unit
L

In testing for 2000 to 2020.

Requested torque K5_REQUESTED_TORQUE

  • Request21 14
  • Service 21PID 14
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
(val × 0.001526)
Range
0 to 100 %
Unit
%

In testing for 2000 to 2020. Not supported for 2021 to 2026.

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Request01 06
  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.2 %
Unit
%

Confirmed for 2021 to 2023, 2025 to 2026. Supported for 2015.

Short term secondary O2 sensor fuel trim (bank 1) STSO2FT1SAE J1979Confirmed

  • Request01 55
  • Service 01PID 55
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.22 %
Unit
%

Confirmed for 2023, 2025. Supported for 2024.

Throttle position #1 K5_THROTTLE_POSITION__1

  • Request21 14
  • Service 21PID 14
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val × 0.0244140625)
Range
-800 to 799 %
Unit
%

In testing for 2000 to 2020. Not supported for 2021 to 2026.

Throttle position #2 K5_THROTTLE_POSITION__2

  • Request21 14
  • Service 21PID 14
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val × 0.0244140625)
Range
-800 to 799 %
Unit
%

In testing for 2000 to 2020. Not supported for 2021 to 2026.

Timing advance SPARKADVSAE J1979Confirmed

Ignition timing spark advance for the first cylinder. Measured in degrees before dead center. Minus is degrees before dead center, positive is degrees after.

  • Request01 0E
  • Service 01PID 0E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2 − 64)
Range
-64 to 63.5 °
Unit
°

Confirmed for 2023. Supported for 2015, 2021 to 2022, 2025 to 2026.

Timing advance #1 K5_TIMING_ADVANCE_1

  • Request21 13
  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits. The value is signed.

Formula
(val × 0.75)
Range
-96 to 95.25 °
Unit
°

In testing for 2000 to 2020. Not supported for 2021, 2023 to 2026.

Timing advance #2 K5_TIMING_ADVANCE_2

  • Request21 13
  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits. The value is signed.

Formula
(val × 0.75)
Range
-96 to 95.25 °
Unit
°

In testing for 2000 to 2020. Not supported for 2021, 2023 to 2026.

Timing advance #3 K5_TIMING_ADVANCE_3

  • Request21 13
  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits. The value is signed.

Formula
(val × 0.75)
Range
-96 to 95.25 °
Unit
°

In testing for 2000 to 2020. Not supported for 2021, 2023 to 2026.

Timing advance #4 K5_TIMING_ADVANCE_4

  • Request21 13
  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits. The value is signed.

Formula
(val × 0.75)
Range
-96 to 95.25 °
Unit
°

In testing for 2000 to 2020. Not supported for 2021, 2023 to 2026.

Torque converter slip K5_TORQUE_CONVERTER_SLIPConfirmed

  • Request22 01 A0
  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2000 to 2020, 2024

Example reply from a 2026 Kia K5.

Bits 128 to 143 of the reply, 16 bits.

0x08C6 = 2246 → (2246 ÷ 4 − 512) = 49.5 rpm

Formula
(val ÷ 4 − 512)
Range
-512 to 15871.75 rpm
Unit
rpm

Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2000 to 2020. Not supported for 2024.

Torque converter slip K5_TORQUE_CONVERTER_SLIP_7E1

  • Request21 A0
  • Service 21PID A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
(val ÷ 4 − 512)
Range
-512 to 15871.75 rpm
Unit
rpm

In testing for 2000 to 2020. Not supported for 2022 to 2023, 2025.

Torque converter slip K5_TQ_CONV_SLIP

  • Request21 A0
  • Service 21PID A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
(val ÷ 4 − 512)
Range
-512 to 15871.75 rpm
Unit
rpm

In testing for 2000 to 2020.

Transmission fluid temperature K5_ATF_T_7E0

Pelican can show this parameter as the transmission fluid temperature.

  • Request21 A0
  • Service 21PID A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 264 to 271 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2000 to 2020.

Turbine speed K5_TURBINE_SPEED_7E1

  • Request21 A0
  • Service 21PID A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 72 to 87 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2000 to 2020. Not supported for 2022 to 2023, 2025.

Turbo boost pressure K5_TURBO_BOOSTConfirmed

  • Request22 E0 21
  • Service 22DID E021
  • Module7E0 → 7E8
  • Every100 ms
  • Testing for 2000 to 2024

Bits 56 to 71 of the reply, 16 bits.

Formula
(val ÷ 831.556909 − 12)
Range
-10 to 66.81 psi
Unit
psi

Confirmed for 2025 to 2026. Not supported for 2021 to 2024.

Turbo boost pressure K5_TURBO_BOOST_P

  • Request21 21
  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
(val × 0.008291)
Range
0 to 543
Unit
Number

In testing for 2000 to 2020.

Type of fuel currently being used by the vehicle FUEL_TYPSAE J1979Confirmed

  • Request01 51
  • Service 01PID 51
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1GASGasoline/petrol
2METHMethanol
3ETHEthanol
4DSLDiesel
5LPGLiquefied petroleum gas
6CNGCompressed natural gas
7PROPPropane
8ELECBattery/electric
9BI_GASBi-fuel vehicle using gasoline/petrol
10BI_METHBi-fuel vehicle using methanol
11BI_ETHBi-fuel vehicle using ethanol
12BI_LPGBi-fuel vehicle using LPG
13BI_CNGBi-fuel vehicle using CNG
14BI_PROPBi-fuel vehicle using propane
15BI_ELECBi-fuel vehicle using battery
16BI_MIXBi-fuel vehicle using battery and combustion engine for propulsion
17HYB_GASHybrid vehicle using gasoline engine for propulsion
18HYB_ETHHybrid vehicle using gasoline engine on ethanol for propulsion
19HYB_DSLHybrid vehicle using diesel engine for propulsion
20HYB_ELECHybrid vehicle using battery for propulsion
21HYB_MIXHybrid vehicle using battery and combustion engine for propulsion
22HYB_REGHybrid vehicle in regeneration mode
23BI_DSLBi-fuel vehicle using diesel
24BI_NGBi-fuel vehicle using natural gas
25BI_DSLBi-fuel vehicle using diesel
26NGNatural gas
27DSL_CNGDual fuel vehicle using diesel and CNG
28DSL_LNGDual fuel vehicle using diesel and LNG
29FC_H2Fuel cell utilizing hydrogen
30HICE_HHOHydrogen Internal Combustion Engine
31KEROKerosene
32HFOHeavy Fuel Oil

Confirmed for 2023, 2025. Supported for 2024.

Variable valve timing temperature K5_CVVT_T

Continuously variable valve timing temperature.

  • Request21 18
  • Service 21PID 18
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 272 to 279 of the reply, 8 bits.

Formula
(val − 48)
Range
-48 to 207 °C
Unit
°C

In testing for 2000 to 2020.

Waste gate duty K5_WASTE_GATE_DUTY

  • Request21 21
  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 408 to 423 of the reply, 16 bits.

Formula
(val × 0.00305176)
Range
0 to 199 %
Unit
%

In testing for 2000 to 2020.

Waste gate position K5_WASTE_GATE_POS

  • Request21 21
  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 424 to 439 of the reply, 16 bits.

Formula
(val × 0.00610352)
Range
0 to 399 %
Unit
%

In testing for 2000 to 2020.

Waste gate target K5_WASTE_GATE_TGT

  • Request21 21
  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 440 to 455 of the reply, 16 bits.

Formula
(val × 0.00610352)
Range
0 to 399 %
Unit
%

In testing for 2000 to 2020.

Engine › Internal

Is ECT sensor 1 supported? ECT_1_SUPSAE J1979Confirmed

  • Request01 67
  • Service 01PID 67
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

Confirmed for 2023. Supported for 2024.

Is ECT sensor 2 supported? ECT_2_SUPSAE J1979Confirmed

  • Request01 67
  • Service 01PID 67
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Number

Confirmed for 2023. Supported for 2024.

Engine › Misfires

Emission-relevant misfires, cylinder #1 K5_MIS_CNT_EMIS_1

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2000 to 2020. Not supported for 2021 to 2026.

Emission-relevant misfires, cylinder #2 K5_MIS_CNT_EMIS_2

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2000 to 2020. Not supported for 2021 to 2026.

Emission-relevant misfires, cylinder #3 K5_MIS_CNT_EMIS_3

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2000 to 2020. Not supported for 2021 to 2026.

Emission-relevant misfires, cylinder #4 K5_MIS_CNT_EMIS_4

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2000 to 2020. Not supported for 2021 to 2026.

Misfires harmful for catalyst cylinder 1 K5_MIS_CAT_1

  • Request21 1D
  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2000 to 2020.

Misfires harmful for catalyst cylinder 2 K5_MIS_CAT_2

  • Request21 1D
  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2000 to 2020.

Misfires harmful for catalyst cylinder 3 K5_MIS_CAT_3

  • Request21 1D
  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2000 to 2020.

Misfires harmful for catalyst cylinder 4 K5_MIS_CAT_4

  • Request21 1D
  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2000 to 2020.

Misfires total counter, all cylinders K5_MIS_CNT_ALL

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 432 to 447 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2000 to 2020. Not supported for 2021 to 2026.

Misfires total counter, cylinder #1 K5_MIS_CNT_1

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2000 to 2020. Not supported for 2021 to 2026.

Misfires total counter, cylinder #2 K5_MIS_CNT_2

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2000 to 2020. Not supported for 2021 to 2026.

Misfires total counter, cylinder #3 K5_MIS_CNT_3

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2000 to 2020. Not supported for 2021 to 2026.

Misfires total counter, cylinder #4 K5_MIS_CNT_4

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2000 to 2020. Not supported for 2021 to 2026.

Misfires, cylinder 1 K5_MIS_1

  • Request21 1D
  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2000 to 2020.

Misfires, cylinder 2 K5_MIS_2

  • Request21 1D
  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2000 to 2020.

Misfires, cylinder 3 K5_MIS_3

  • Request21 1D
  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2000 to 2020.

Misfires, cylinder 4 K5_MIS_4

  • Request21 1D
  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2000 to 2020.

Engine › OxygenSensors

02S Bank 1, Sensor 1 present O2S11_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023. Supported for 2021 to 2022, 2025 to 2026.

02S Bank 1, Sensor 2 present O2S12_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023. Supported for 2021 to 2022, 2025 to 2026.

02S Bank 1, Sensor 3 present O2S13_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023. Supported for 2021 to 2022, 2025 to 2026.

02S Bank 1, Sensor 4 present O2S14_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023. Supported for 2021 to 2022, 2025 to 2026.

02S Bank 2, Sensor 1 present O2S21_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023. Supported for 2021 to 2022, 2025 to 2026.

02S Bank 2, Sensor 2 present O2S22_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023. Supported for 2021 to 2022, 2025 to 2026.

02S Bank 2, Sensor 3 present O2S23_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023. Supported for 2021 to 2022, 2025 to 2026.

02S Bank 2, Sensor 4 present O2S24_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023. Supported for 2021 to 2022, 2025 to 2026.

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Request01 34
  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32768)
Range
0 to 1.99
Unit
Number

Confirmed for 2021 to 2023, 2025 to 2026.

O2S Output Voltage Bank 1, Sensor 2 O2S12SAE J1979Confirmed

  • Request01 15
  • Service 01PID 15
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 200)
Range
0 to 1.275 V
Unit
V

Confirmed for 2023. Supported for 2021 to 2022, 2025 to 2026.

SHRTFT associated with O2S11 SHRTFT11SAE J1979Confirmed

  • Request01 14
  • Service 01PID 14
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 128)
Range
-100 to 99.22 %
Unit
%

Confirmed for 2023. Supported for 2021 to 2022, 2025 to 2026.

Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed

  • Request01 34
  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 256 − 128)
Range
-128 to 127.996 mA
Unit
mA

Confirmed for 2021 to 2023, 2025 to 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.