Commanded evaporative purge K5_COMMANDED_EVAPORATIVE_PURGE
- Request
21 02 - Service 21
PID 02 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 160 to 167 of the reply, 8 bits.
- Formula
(val × 0.390625)- Range
- 0 to 99.6 %
- Unit
- %
In testing for 2000 to 2020. Not supported for 2021 to 2026.
Intake camshaft position actual K5_INTAKE_CAMSHAFT_POSITION_ACTUAL
- Request
21 17 - Service 21
PID 17 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 40 to 55 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val ÷ 128)- Range
- -256 to 255 °
- Unit
- °
In testing for 2000 to 2020.
Intake camshaft position commanded K5_INTAKE_CAMSHAFT_POSITION_COMMANDED
- Request
21 17 - Service 21
PID 17 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits. The value is signed.
- Formula
(val ÷ 2)- Range
- -64 to 63.5 °
- Unit
- °
In testing for 2000 to 2020.
Intake manifold absolute pressure K5_INTAKE_MANIFOLD_ABSOLUTE_PRESSURE
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 128 to 143 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 256)- Range
- 0 to 255 kPa
- Unit
- kPa
In testing for 2000 to 2020. Not supported for 2021 to 2026.
Knock retard cylinder #1 K5_KNOCK_RETARD_CYLINDER_1
- Request
21 16 - Service 21
PID 16 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
(val × 0.75)- Range
- 0 to 191.25 °
- Unit
- °
In testing for 2000 to 2020. Not supported for 2021 to 2026.
Knock retard cylinder #2 K5_KNOCK_RETARD_CYLINDER_2
- Request
21 16 - Service 21
PID 16 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
(val × 0.75)- Range
- 0 to 191.25 °
- Unit
- °
In testing for 2000 to 2020. Not supported for 2021 to 2026.
Knock retard cylinder #3 K5_KNOCK_RETARD_CYLINDER_3
- Request
21 16 - Service 21
PID 16 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val × 0.75)- Range
- 0 to 191.25 °
- Unit
- °
In testing for 2000 to 2020. Not supported for 2021 to 2026.
Knock retard cylinder #4 K5_KNOCK_RETARD_CYLINDER_4
- Request
21 16 - Service 21
PID 16 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
(val × 0.75)- Range
- 0 to 191.25 °
- Unit
- °
In testing for 2000 to 2020. Not supported for 2021 to 2026.
Oxygen sensor 1 bank 1 K5_OXYGEN_SENSOR_11
- Request
21 02 - Service 21
PID 02 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 0.00521 − 0.2)- Range
- -0.2 to 1.12 V
- Unit
- V
In testing for 2000 to 2020. Not supported for 2021 to 2026.
Oxygen sensor 2 bank 1 K5_OXYGEN_SENSOR_21
- Request
21 02 - Service 21
PID 02 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val × 0.00521 − 0.2)- Range
- -0.2 to 1.12 V
- Unit
- V
In testing for 2000 to 2020. Not supported for 2021 to 2026.