Battery parameters
The Toyota Camry Hybrid has 214 battery parameters.
● Confirmed◆ In testing○ Supported× Not supported
+BM voltage CAMRYH_BM_V
- Request
21 41 - Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 56 to 71 of the reply, 16 bits.
- Formula
(val × 5 ÷ 4096)- Range
- 0 to 79.998 V
- Unit
- V
In testing for 2007 to 2026.
1st turbocharger outlet pressure, control valve CAMRYH_1ST_TRUBOCHARGER_P
- Request
22 11 CD - Service 22
DID 11CD - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 300 kPa
- Unit
- kPa
In testing for 2007 to 2021, 2023 to 2026. Not supported for 2022.
2nd turbocharger outlet pressure CAMRYH_2ND_TRUBOCHARGER_OUTLET_P
- Request
22 11 AF - Service 22
DID 11AF - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 300 kPa
- Unit
- kPa
In testing for 2007 to 2026.
2nd turbocharger outlet pressure, control valve CAMRYH_2ND_TRUBOCHARGER_P
- Request
22 11 CD - Service 22
DID 11CD - Module
700 → 708 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 300 kPa
- Unit
- kPa
In testing for 2007 to 2021, 2023 to 2026. Not supported for 2022.
12V battery current CAMRYH_12V_CConfirmed
- Request
22 15 F7 - Service 22
DID 15F7 - Module
7D2 → 7DA - Every
500 ms - Testing for 2007 to 2018, 2020, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 0 to 15 of the reply, 16 bits.
0x7276 = 29302 → (29302 × 38.147 ÷ 10000 − 125) = -13.221661 A
- Formula
(val × 38.147 ÷ 10000 − 125)- Range
- -125 to 124 A
- Unit
- A
Confirmed for 2019, 2021 to 2023. In testing for 2008 to 2011, 2014 to 2018, 2020, 2024, 2026. Not supported for 2007, 2012 to 2013, 2025.
12V battery temperature CAMRYH_12V_TConfirmed
- Request
22 15 F8 - Service 22
DID 15F8 - Module
7D2 → 7DA - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 0 to 15 of the reply, 16 bits.
0x0153 = 339 → (339 ÷ 10 − 40) = -6.1 °C
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
Confirmed for 2019, 2021 to 2023. In testing for 2008 to 2011, 2014 to 2018, 2020, 2024, 2026. Not supported for 2007, 2012 to 2013, 2025.
12V battery voltage CAMRYH_12V_V_7D2Confirmed
Pelican can show this parameter as the starter battery voltage.
- Request
22 15 EE - Service 22
DID 15EE - Module
7D2 → 7DA - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 0 to 7 of the reply, 8 bits.
0x28 = 40 → (40 × 0.31448 + 0.0125) = 12.5917 V
- Formula
(val × 0.31448 + 0.0125)- Range
- 0 to 80.2 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2008 to 2011, 2014 to 2018, 2020, 2024, 2026. Not supported for 2007, 2012 to 2013, 2025.
12V battery voltage before system main relay CAMRYH_12V_BAT_V_BEFORE_SMR
- Request
22 10 7E - Service 22
DID 107E - Module
7D2 → 7DA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 61 ÷ 50000 + 11.25)- Range
- 0 to 11.56 V
- Unit
- V
In testing for 2007 to 2026.
12V battery voltage smoothed CAMRYH_12V_BAT_V_SMOOTHED
- Request
22 1F 42 - Service 22
DID 1F42 - Module
7D2 → 7DA - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2007 to 2026.
Accumulated time of battery low CAMRYH_ACCUMULATED_TIME_BAT
- Request
21 92 - Service 21
PID 92 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 56 to 71 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2012 to 2017.
Accumulated time of battery too high CAMRYH_ACCUMULATED_TIME_BAT_TOO
- Request
21 92 - Service 21
PID 92 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 88 to 103 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2012 to 2017.
Air fuel sensor voltage, bank 1 sensor 1 CAMRYH_AFS_VOLTAGE_B1S1Confirmed
- Request
21 04 - Service 21
PID 04 - Module
7E0 → 7E8 - Every
1 s - Testing for 2008 to 2011, 2014 to 2026
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val × 7.99 ÷ 65535)- Range
- 0 to 7.99 V
- Unit
- V
Confirmed for 2012 to 2013. In testing for 2008 to 2011, 2014 to 2018, 2020 to 2021, 2024, 2026. Supported for 2007. Not supported for 2019, 2022 to 2023, 2025.
Aux. battery capacity after IG OFF CAMRYH_AUX_BAT_CAP_AFTER_IG_OFF
- Request
22 15 E8 - Service 22
DID 15E8 - Module
700 → 708 - Every
30 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val − 128)- Range
- -128 to 127 Ah
- Unit
- Ah
In testing for 2007 to 2026.
Aux. battery capacity after IG ON CAMRYH_AUX_BAT_CAP_AFTER_IG_ON
- Request
22 15 E8 - Service 22
DID 15E8 - Module
700 → 708 - Every
30 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val − 128)- Range
- -128 to 127 Ah
- Unit
- Ah
In testing for 2007 to 2026.
Auxiliary battery current CAMRYH_AUXILIARY_BAT
- Request
22 18 02 - Service 22
DID 1802 - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 2525 ÷ 13107 − 12500)- Range
- -12500 to -12451 A
- Unit
- A
In testing for 2007 to 2026.
Auxiliary battery temperature CAMRYH_AUXILIARY_BAT_T
- Request
21 41 - Service 21
PID 41 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215
- Unit
- Number
In testing for 2012 to 2017.
Auxiliary battery voltage CAMRYH_AUX_BAT_V
- Request
22 10 02 - Service 22
DID 1002 - Module
7D2 → 7DA - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 61 ÷ 50000)- Range
- 0 to 79.95 V
- Unit
- V
In testing for 2007 to 2026.
Auxiliary battery voltage CAMRYH_AUXILIARY_BAT_V
- Request
21 81 - Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
(val × 47 ÷ 38550 − 40)- Range
- -40 to 39.9 V
- Unit
- V
In testing for 2012 to 2017.
Battery block 1 voltage CAMRYH_BAT_BLOCK_V_V01
- Request
21 81 - Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0012205692)- Range
- 0 to 79.99 V
- Unit
- V
In testing for 2012 to 2017.
Battery block 2 voltage CAMRYH_BAT_BLOCK_V_V02
- Request
21 81 - Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 0.0012205692)- Range
- 0 to 79.99 V
- Unit
- V
In testing for 2012 to 2017.
Battery block 3 voltage CAMRYH_BAT_BLOCK_V_V03
- Request
21 81 - Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val × 0.0012205692)- Range
- 0 to 79.99 V
- Unit
- V
In testing for 2012 to 2017.
Battery block 4 voltage CAMRYH_BAT_BLOCK_V_V04
- Request
21 81 - Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val × 0.0012205692)- Range
- 0 to 79.99 V
- Unit
- V
In testing for 2012 to 2017.
Battery block 5 voltage CAMRYH_BAT_BLOCK_V_V05
- Request
21 81 - Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val × 0.0012205692)- Range
- 0 to 79.99 V
- Unit
- V
In testing for 2012 to 2017.
Battery block 6 voltage CAMRYH_BAT_BLOCK_V_V06
- Request
21 81 - Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
(val × 0.0012205692)- Range
- 0 to 79.99 V
- Unit
- V
In testing for 2012 to 2017.
Battery block 7 voltage CAMRYH_BAT_BLOCK_V_V07
- Request
21 81 - Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val × 0.0012205692)- Range
- 0 to 79.99 V
- Unit
- V
In testing for 2012 to 2017.
Battery block 8 voltage CAMRYH_BAT_BLOCK_V_V08
- Request
21 81 - Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
(val × 0.0012205692)- Range
- 0 to 79.99 V
- Unit
- V
In testing for 2012 to 2017.
Battery block 9 voltage CAMRYH_BAT_BLOCK_V_V09
- Request
21 81 - Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
(val × 0.0012205692)- Range
- 0 to 79.99 V
- Unit
- V
In testing for 2012 to 2017.
Battery block 10 voltage, raw count CAMRYH_BAT_BLOCK_V_V10_RAW
- Request
21 81 - Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
(val × 7999 ÷ 6553500)- Range
- 0 to 79.99
- Unit
- Number
In testing for 2012 to 2017.
Battery block 11 voltage CAMRYH_BAT_BLOCK_V_V11
- Request
21 81 - Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
(val × 0.0012205692)- Range
- 0 to 79.99 V
- Unit
- V
In testing for 2012 to 2017.
Battery block 12 voltage CAMRYH_BAT_BLOCK_V_V12
- Request
21 81 - Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val × 0.0012205692)- Range
- 0 to 79.99 V
- Unit
- V
In testing for 2012 to 2017.
Battery block 13 voltage CAMRYH_BAT_BLOCK_V_V13
- Request
21 81 - Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
(val × 0.0012205692)- Range
- 0 to 79.99 V
- Unit
- V
In testing for 2012 to 2017.
Battery block 14 voltage CAMRYH_BAT_BLOCK_V_V14
- Request
21 81 - Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
(val × 0.0012205692)- Range
- 0 to 79.99 V
- Unit
- V
In testing for 2012 to 2017.
Battery block 16 voltage CAMRYH_BAT_BLOCK_V_V16
- Request
21 81 - Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 V
- Unit
- V
In testing for 2012 to 2017.
Battery block 17 voltage CAMRYH_BAT_BLOCK_V_V17
- Request
21 81 - Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 256 to 271 of the reply, 16 bits.
- Formula
(val × 7999 ÷ 6553500)- Range
- 0 to 79.99 V
- Unit
- V
In testing for 2012 to 2017.
Battery block with the maximum voltage CAMRYH_BAT_BLOCK_NUMBER_MAX_V
- Request
21 92 - Service 21
PID 92 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val + 1)- Range
- 0 to 256
- Unit
- Number
In testing for 2012 to 2017.
Battery block with the minimum voltage CAMRYH_BAT_BLOCK_NUMBER_MIN_V
- Request
21 92 - Service 21
PID 92 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val + 1)- Range
- 0 to 256
- Unit
- Number
In testing for 2012 to 2017.
Battery block, maximum voltage CAMRYH_BAT_BLOCK_MAX_V
- Request
21 92 - Service 21
PID 92 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
(val × 0.0012205692)- Range
- 0 to 79.99 V
- Unit
- V
In testing for 2012 to 2017.
Battery block, minimum voltage CAMRYH_BAT_BLOCK_MIN_V
- Request
21 92 - Service 21
PID 92 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0012205692)- Range
- 0 to 79.99 V
- Unit
- V
In testing for 2012 to 2017.
Battery current CAMRYH_BAT_CURRENT
- Request
21 42 - Service 21
PID 42 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 50 ÷ 13107 − 125)- Range
- -125 to 124.9 A
- Unit
- A
In testing for 2007 to 2026.
Battery current CAMRYH_BAT_CURRENT_700
- Request
22 15 F7 - Service 22
DID 15F7 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 49 ÷ 12850 − 125)- Range
- -125 to 124.9 A
- Unit
- A
In testing for 2007 to 2021, 2023 to 2026. Not supported for 2022.
Battery heater temperature CAMRYH_BAT_HEATER_T
- Request
22 18 24 - Service 22
DID 1824 - Module
747 → 74F - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2007 to 2026.
Battery status of full charge CAMRYH_BAT_STAT_FULL_CHG
- Request
22 15 E5 - Service 22
DID 15E5 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 255 ÷ 2)- Range
- 0 to 32512.5 Ah
- Unit
- Ah
In testing for 2007 to 2021, 2023 to 2026. Not supported for 2022.
Battery temperature CAMRYH_BAT_T
- Request
21 42 - Service 21
PID 42 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 6513.5 °C
- Unit
- °C
In testing for 2007 to 2026.
Battery temperature CAMRYH_BAT_T_700
- Request
22 15 F8 - Service 22
DID 15F8 - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 2007 to 2026.
Battery temperature CAMRYH_BAT_T_700_2
- Request
22 1F F8 - Service 22
DID 1FF8 - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 9 ÷ 50 − 40)- Range
- -40 to 11756.3 °F
- Unit
- °F
In testing for 2007 to 2026.
Battery temperature 01 CAMRYH_BAT_T_01
- Request
22 18 14 - Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 5000000 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2007 to 2026.
Battery temperature 02 CAMRYH_BAT_T_02
- Request
22 18 14 - Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 5000000 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2007 to 2026.
Battery temperature 03 CAMRYH_BAT_T_03
- Request
22 18 14 - Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 5000000 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2007 to 2026.
Battery temperature 04 CAMRYH_BAT_T_04
- Request
22 18 14 - Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 5000000 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2007 to 2026.
Battery temperature 05 CAMRYH_BAT_T_05
- Request
22 18 14 - Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 5000000 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2007 to 2026.
Battery temperature 06 CAMRYH_BAT_T_06
- Request
22 18 14 - Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 5000000 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2007 to 2026.
Battery temperature 07 CAMRYH_BAT_T_07
- Request
22 18 14 - Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 5000000 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2007 to 2026.
Battery temperature 08 CAMRYH_BAT_T_08
- Request
22 18 14 - Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 5000000 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2007 to 2026.
Battery temperature 09 CAMRYH_BAT_T_09
- Request
22 18 14 - Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 5000000 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2007 to 2026.
Battery temperature 10 CAMRYH_BAT_T_10
- Request
22 18 14 - Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 5000000 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2007 to 2026.
Battery temperature 11 CAMRYH_BAT_T_11
- Request
22 18 14 - Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 5000000 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2007 to 2026.
Battery temperature 12 CAMRYH_BAT_T_12
- Request
22 18 14 - Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 5000000 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2007 to 2026.
Battery temperature 13 CAMRYH_BAT_T_13
- Request
22 18 14 - Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 5000000 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2007 to 2026.
Battery temperature 14 CAMRYH_BAT_T_14
- Request
22 18 14 - Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 5000000 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2007 to 2026.
Battery temperature 15 CAMRYH_BAT_T_15
- Request
22 18 14 - Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 5000000 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2007 to 2026.
Battery temperature 16 CAMRYH_BAT_T_16
- Request
22 18 14 - Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 5000000 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2007 to 2026.
Battery voltage CAMRYH_12V_VConfirmed
Pelican can show this parameter as the starter battery voltage.
- Request
22 10 02 - Service 22
DID 1002 - Module
700 → 708 - Every
1 s - Testing for 2007 to 2018, 2020 to 2021, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 0 to 15 of the reply, 16 bits.
0x2740 = 10048 → (10048 × 12.207 ÷ 10000) = 12.265594 V
- Formula
(val × 12.207 ÷ 10000)- Range
- 0 to 79 V
- Unit
- V
Confirmed for 2019, 2022 to 2023. In testing for 2008 to 2011, 2014 to 2018, 2020 to 2021, 2024, 2026. Not supported for 2007, 2012 to 2013, 2025.
Battery voltage CAMRYH_BAT_VConfirmed
- Request
21 13 - Service 21
PID 13 - Module
7C0 → 7C8 - Every
1 s - Testing for 2008 to 2011, 2014 to 2026
Example reply from a 2013 Toyota Camry Hybrid.
Bits 0 to 7 of the reply, 8 bits.
0x8D = 141 → (141 ÷ 10) = 14.1 V
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
Confirmed for 2007, 2012 to 2013. In testing for 2008 to 2011, 2014 to 2018, 2020 to 2021, 2024, 2026. Not supported for 2019, 2022 to 2023, 2025.
Battery voltage CAMRYH_BATTERY_VOLTAGEConfirmed
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing for 2008 to 2011, 2014 to 2026
Example reply from a 2013 Toyota Camry Hybrid.
Bits 184 to 199 of the reply, 16 bits.
0x3888 = 14472 → (14472 ÷ 1000) = 14.472 V
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
Confirmed for 2012 to 2013. In testing for 2008 to 2011, 2014 to 2018, 2020 to 2021, 2024, 2026. Supported for 2007. Not supported for 2019, 2022 to 2023, 2025.
Boost converter voltage after boosting CAMRYH_VH_V_AFTER_BOOSTING
- Request
22 10 B0 - Service 22
DID 10B0 - Module
7D2 → 7DA - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2)- Range
- 0 to 32767 V
- Unit
- V
In testing for 2007 to 2026.
Boost converter voltage after boosting CAMRYH_VH_V_AFTER_BOOSTING_7E2
- Request
21 74 - Service 21
PID 74 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 56 to 71 of the reply, 16 bits.
- Formula
(val ÷ 2)- Range
- 0 to 32767 V
- Unit
- V
In testing for 2012 to 2017.
Boost converter voltage before boosting CAMRYH_VL_V_BEFORE_BOOSTING
- Request
22 10 B0 - Service 22
DID 10B0 - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2)- Range
- 0 to 32767 V
- Unit
- V
In testing for 2007 to 2026.
Boost converter voltage before boosting CAMRYH_VL_V_BEFORE_BOOSTING_7E2
- Request
21 74 - Service 21
PID 74 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
(val ÷ 2)- Range
- 0 to 32767 V
- Unit
- V
In testing for 2012 to 2017.
Charge contactor current CAMRYH_SCC_SOLENOID_CURRENTConfirmed
- Request
21 A3 - Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing for 2008 to 2011, 2014 to 2018, 2020 to 2021, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 24 to 31 of the reply, 8 bits.
0x45 = 69 → 69 mA
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
Confirmed for 2007, 2012 to 2013, 2019, 2022 to 2023. In testing for 2008 to 2011, 2014 to 2018, 2020 to 2021, 2024, 2026. Not supported for 2025.
Charging integrated current of aux. battery CAMRYH_CHG_INTEGRATED
- Request
22 15 E8 - Service 22
DID 15E8 - Module
700 → 708 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729.5 Ah
- Unit
- Ah
In testing for 2007 to 2026.
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Request
01 42 - Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65535 V
- Unit
- V
Confirmed for 2012. Supported for 2007, 2013, 2018 to 2019, 2021 to 2023, 2025.
Converter input voltage too high CAMRYH_OVERVOLTAGE_INPUT
- Request
21 74 - Service 21
PID 74 - Module
7E2 → 7EA - Every
1 s - Testing
Bit 33 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2012 to 2017.
Dark current of battery CAMRYH_DARK_CURRENT_BAT
- Request
22 15 E7 - Service 22
DID 15E7 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2007 to 2026.
DC-DC converter high side voltage CAMRYH_DC_DC_CONV_HIGH_SIDE_V
- Request
22 11 1E - Service 22
DID 111E - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 1220703 ÷ 10000000)- Range
- 0 to 7999 V
- Unit
- V
In testing for 2007 to 2026.
DC-DC converter low side voltage CAMRYH_DC_DC_CONV_LOW_SIDE_V
- Request
22 11 1D - Service 22
DID 111D - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 1953 ÷ 25000)- Range
- 0 to 19.92 V
- Unit
- V
In testing for 2007 to 2026.
DC-DC converter, target voltage before charging CAMRYH_DC_DC_CONV_TGT_V
- Request
22 11 1F - Service 22
DID 111F - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 1220703 ÷ 10000000)- Range
- 0 to 7999 V
- Unit
- V
In testing for 2007 to 2026.
Delta SOC CAMRYH_DELTA_SOC
- Request
21 98 - Service 21
PID 98 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127 %
- Unit
- %
In testing for 2012 to 2017.
Discharging integrated current of aux. battery CAMRYH_DISCHARGING
- Request
22 15 E8 - Service 22
DID 15E8 - Module
700 → 708 - Every
30 s - Testing
Bits 32 to 63 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729.5 Ah
- Unit
- Ah
In testing for 2007 to 2026.
Distance since last battery cable disconnection CAMRYH_DIST_SINCE_BAT_DISCConfirmed
- Request
22 10 6C - Service 22
DID 106C - Module
700 → 708 - Every
1 s - Testing for 2007 to 2018, 2020 to 2021, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 0 to 15 of the reply, 16 bits.
0xFFFF = 65535 → 65,535 km
- Formula
val- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2019, 2022 to 2023. In testing for 2008 to 2011, 2014 to 2018, 2020 to 2021, 2024, 2026. Not supported for 2007, 2012 to 2013, 2025.
Engine control module control mode, driving control mode=1,current sensor offset mode=2,external charge control mode=3,power supply end mode=4 CAMRYH_ENG_CTRL_MODULE_CTRL_1_2_3_4
- Request
21 9B - Service 21
PID 9B - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2017.
High voltage battery charge control, kw CAMRYH_HVBAT_CHG_CTRL_KW
- Request
21 98 - Service 21
PID 98 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val ÷ 2 − 64)- Range
- -64 to 63.5
- Unit
- Number
In testing for 2012 to 2017.
High voltage battery discharge control, kw CAMRYH_HVBAT_DCHG_CTRL_KW
- Request
21 98 - Service 21
PID 98 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val ÷ 2 − 64)- Range
- -64 to 63.5
- Unit
- Number
In testing for 2012 to 2017.
High voltage battery intake air temperature CAMRYH_HVBAT_IAT
- Request
21 87 - Service 21
PID 87 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0039047837 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2017.
HV battery charge voltage CAMRYH_HVBAT_CHRG_V
- Request
22 16 09 - Service 22
DID 1609 - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 100 V
- Unit
- V
In testing for 2008 to 2011, 2014 to 2018, 2020, 2024, 2026. Not supported for 2007, 2012 to 2013, 2019, 2021 to 2023, 2025.
HV battery charge, displayed CAMRYH_HVBAT_SOC_DISPLAY
Pelican can show this parameter as the state of charge.
- Request
22 17 39 - Service 22
DID 1739 - Module
745 → 74D - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2017, 2019 to 2024, 2026. Not supported for 2018, 2025.
HV battery charge, maximum CAMRYH_HVBAT_SOC_MAXConfirmed
- Request
22 10 6C - Service 22
DID 106C - Module
7D2 → 7DA - Every
5 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 8 to 15 of the reply, 8 bits.
0x4E = 78 → (78 ÷ 2) = 39 %
- Formula
(val ÷ 2)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2019, 2021 to 2023. In testing for 2008 to 2011, 2014 to 2017, 2020, 2024, 2026. Not supported for 2007, 2012 to 2013, 2018, 2025.
HV battery charge, minimum CAMRYH_HVBAT_SOC_MINConfirmed
- Request
22 10 6C - Service 22
DID 106C - Module
7D2 → 7DA - Every
5 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 16 to 23 of the reply, 8 bits.
0x3C = 60 → (60 ÷ 2) = 30 %
- Formula
(val ÷ 2)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2019, 2021 to 2023. In testing for 2008 to 2011, 2014 to 2017, 2020, 2024, 2026. Not supported for 2007, 2012 to 2013, 2018, 2025.
HV battery current CAMRYH_HVBAT_CConfirmed
- Request
22 1F 9A - Service 22
DID 1F9A - Module
7D2 → 7DA - Every
500 ms - Testing for 2007 to 2018, 2020, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 32 to 47 of the reply, 16 bits. The value is signed.
0x02BA = 698 → (698 ÷ 10) = 69.8 A
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 A
- Unit
- A
Confirmed for 2019, 2021 to 2023. In testing for 2008 to 2011, 2014 to 2018, 2020, 2024, 2026. Not supported for 2007, 2012 to 2013, 2025.
HV battery maximum temperature CAMRYH_HVBAT_MAX_T
- Request
22 18 29 - Service 22
DID 1829 - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2008 to 2011, 2014 to 2018, 2020, 2024, 2026. Not supported for 2007, 2012 to 2013, 2019, 2021 to 2023, 2025.
HV battery minimum temperature CAMRYH_HVBAT_MIN_T
- Request
22 18 2A - Service 22
DID 182A - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2008 to 2011, 2014 to 2018, 2020, 2024, 2026. Not supported for 2007, 2012 to 2013, 2019, 2021 to 2023, 2025.
HV battery temperature 1 CAMRYH_T_BATT_TB1
- Request
21 87 - Service 21
PID 87 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 0.0039047837 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2017.
HV battery temperature 2 CAMRYH_T_BATT_TB2
- Request
21 87 - Service 21
PID 87 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val × 0.0039047837 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2017.
HV battery temperature 3 CAMRYH_T_BATT_TB3
- Request
21 87 - Service 21
PID 87 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val × 0.0039047837 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2017.
HV battery voltage CAMRYH_HVBAT_VConfirmed
- Request
22 1F 9A - Service 22
DID 1F9A - Module
7D2 → 7DA - Every
500 ms - Testing for 2007 to 2018, 2020, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 16 to 31 of the reply, 16 bits.
0x3CC0 = 15552 → (15552 × 156.25 ÷ 10000) = 243 V
- Formula
(val × 156.25 ÷ 10000)- Range
- 0 to 1023 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2008 to 2011, 2014 to 2018, 2020, 2024, 2026. Not supported for 2007, 2012 to 2013, 2025.
Hybrid battery 1 fan CAMRYH_BAT_1_FAN
- Request
22 18 02 - Service 22
DID 1802 - Module
7D2 → 7DA - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127 %
- Unit
- %
In testing for 2007 to 2026.
Hybrid battery temperature 1 CAMRYH_BAT_T_1
- Request
22 18 14 - Service 22
DID 1814 - Module
7D2 → 7DA - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 458 ÷ 65535 − 58)- Range
- -58 to 400 °F
- Unit
- °F
In testing for 2007 to 2026.
Hybrid battery temperature 2 CAMRYH_BAT_T_2
- Request
22 18 14 - Service 22
DID 1814 - Module
7D2 → 7DA - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 9 ÷ 5 − 58)- Range
- -58 to 401 °F
- Unit
- °F
In testing for 2007 to 2026.
Hybrid battery temperature 3 CAMRYH_BAT_T_3
- Request
22 18 14 - Service 22
DID 1814 - Module
7D2 → 7DA - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val × 458 ÷ 65535 − 58)- Range
- -58 to 400 °F
- Unit
- °F
In testing for 2007 to 2026.
Initial engine battery voltage lower limit CAMRYH_INITIAL_ENG_BAT_V_LO
- Request
22 15 F6 - Service 22
DID 15F6 - Module
700 → 708 - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2007 to 2026.
Inverter input voltage too high CAMRYH_OVERVOLTAGE_INPUT_INVERTER
- Request
21 74 - Service 21
PID 74 - Module
7E2 → 7EA - Every
1 s - Testing
Bit 34 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2012 to 2017.
Main connector solenoid current CAMRYH_SMC_SOLENOID_CURRENTConfirmed
- Request
21 A3 - Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing for 2008 to 2011, 2014 to 2018, 2020 to 2021, 2024 to 2026
Example reply from a 2013 Toyota Camry Hybrid.
Bits 32 to 39 of the reply, 8 bits.
0x00 = 0 → 0 mA
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
Confirmed for 2007, 2012 to 2013. In testing for 2008 to 2011, 2014 to 2018, 2020 to 2021, 2024, 2026. Supported for 2019, 2022 to 2023. Not supported for 2025.
Main relay a, solenoid current CAMRYH_SLA_SOLENOID_CURRENTConfirmed
- Request
21 A3 - Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing for 2008 to 2011, 2014 to 2018, 2020 to 2021, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0 mA
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
Confirmed for 2007, 2012 to 2013, 2019, 2022 to 2023. In testing for 2008 to 2011, 2014 to 2018, 2020 to 2021, 2024, 2026. Not supported for 2025.
Main relay r solenoid current CAMRYH_SLR_SOLENOID_CURRENTConfirmed
- Request
21 A3 - Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing for 2008 to 2011, 2014 to 2018, 2020 to 2021, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 8 to 15 of the reply, 8 bits.
0x00 = 0 → 0 mA
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
Confirmed for 2007, 2012 to 2013, 2019, 2022 to 2023. In testing for 2008 to 2011, 2014 to 2018, 2020 to 2021, 2024, 2026. Not supported for 2025.
Number of battery blocks CAMRYH_NUM_BAT_BLOCKS
- Request
21 92 - Service 21
PID 92 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2017.
Output speed sensor voltage CAMRYH_NOUT_SENS_V
- Request
21 81 - Service 21
PID 81 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
(val ÷ 13107)- Range
- 0 to 4.999 V
- Unit
- V
In testing for 2007 to 2026.
Regenerative braking cooperation CAMRYH_REGEN_COOPERATIONConfirmed
- Request
21 58 - Service 21
PID 58 - Module
7B0 → 7B8 - Every
1 s - Testing for 2008 to 2011, 2014 to 2018, 2020 to 2021, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bit 0 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2007, 2012 to 2013, 2019, 2022 to 2023. In testing for 2008 to 2011, 2014 to 2018, 2020 to 2021, 2024, 2026. Not supported for 2025.
Regenerative operation CAMRYH_FR_REGEN_OPERATIONConfirmed
- Request
21 48 - Service 21
PID 48 - Module
7B0 → 7B8 - Every
1 s - Testing for 2008 to 2011, 2014 to 2018, 2020 to 2021, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 16 to 31 of the reply, 16 bits.
0x0000 = 0 → 0 N·m
- Formula
val- Range
- 0 to 65535 N·m
- Unit
- N·m
Confirmed for 2007, 2012 to 2013, 2019, 2022 to 2023. In testing for 2008 to 2011, 2014 to 2018, 2020 to 2021, 2024, 2026. Not supported for 2025.
Regenerative request CAMRYH_FR_REGEN_REQUESTConfirmed
- Request
21 48 - Service 21
PID 48 - Module
7B0 → 7B8 - Every
1 s - Testing for 2008 to 2011, 2014 to 2018, 2020 to 2021, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → 0 N·m
- Formula
val- Range
- 0 to 65535 N·m
- Unit
- N·m
Confirmed for 2007, 2012 to 2013, 2019, 2022 to 2023. In testing for 2008 to 2011, 2014 to 2018, 2020 to 2021, 2024, 2026. Not supported for 2025.
Relay control solenoid current CAMRYH_SRC_SOLENOID_CURRENTConfirmed
- Request
21 A3 - Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing for 2008 to 2011, 2014 to 2018, 2020 to 2021, 2024 to 2026
Example reply from a 2013 Toyota Camry Hybrid.
Bits 40 to 47 of the reply, 8 bits.
0x00 = 0 → 0 mA
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
Confirmed for 2007, 2012 to 2013. In testing for 2008 to 2011, 2014 to 2018, 2020 to 2021, 2024, 2026. Supported for 2019, 2022 to 2023. Not supported for 2025.
Service contactor solenoid current CAMRYH_SSC_SOLENOID_CURRENTConfirmed
- Request
21 A3 - Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing for 2008 to 2011, 2014 to 2018, 2020 to 2021, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 16 to 23 of the reply, 8 bits.
0x2B = 43 → 43 mA
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
Confirmed for 2007, 2012 to 2013, 2019, 2022 to 2023. In testing for 2008 to 2011, 2014 to 2018, 2020 to 2021, 2024, 2026. Not supported for 2025.
Sleep time of battery sensor CAMRYH_SLEEP_TIME_BATSENS
- Request
22 15 F0 - Service 22
DID 15F0 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 h
- Unit
- h
In testing for 2007 to 2021, 2023 to 2026. Not supported for 2022.
SOC at ignition on CAMRYH_SOC_AFTER_IG_ON
- Request
21 98 - Service 21
PID 98 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127 %
- Unit
- %
In testing for 2012 to 2017.
SOC max CAMRYH_SOC_MAX
- Request
21 98 - Service 21
PID 98 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127 %
- Unit
- %
In testing for 2012 to 2017.
SOC min CAMRYH_SOC_MIN
- Request
21 98 - Service 21
PID 98 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127 %
- Unit
- %
In testing for 2012 to 2017.
State of charge CAMRYH_SOCConfirmed
Pelican can show this parameter as the state of charge.
- Request
22 1F 5B - Service 22
DID 1F5B - Module
7D2 → 7DA - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 0 to 7 of the reply, 8 bits.
0x4F = 79 → (79 × 100 ÷ 255) = 30.980392 %
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
State of charge CAMRYH_ST_CHG_ALL_BAT
- Request
21 01 - Service 21
PID 01 - Module
7E2 → 7EA - Every
30 s - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2017.
Turbine speed sensor voltage CAMRYH_NT_SENS_V
- Request
21 81 - Service 21
PID 81 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 13107)- Range
- 0 to 4.999 V
- Unit
- V
In testing for 2007 to 2026.
Voltage of battery sensor CAMRYH_V_BATSENS
- Request
22 15 EE - Service 22
DID 15EE - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 13333 ÷ 10922500)- Range
- 0 to 79.9979 V
- Unit
- V
In testing for 2007 to 2021, 2023 to 2026. Not supported for 2022.
Battery › Cells
HV battery cell #01 voltage CAMRYH_HVBAT_C01_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #02 voltage CAMRYH_HVBAT_C02_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #03 voltage CAMRYH_HVBAT_C03_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #04 voltage CAMRYH_HVBAT_C04_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #05 voltage CAMRYH_HVBAT_C05_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 64 to 79 of the reply, 16 bits.
0xB11A = 45338 → (45338 × 5 ÷ 65535) = 3.459068 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #06 voltage CAMRYH_HVBAT_C06_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 80 to 95 of the reply, 16 bits.
0xB11A = 45338 → (45338 × 5 ÷ 65535) = 3.459068 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #07 voltage CAMRYH_HVBAT_C07_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 96 to 111 of the reply, 16 bits.
0xB11A = 45338 → (45338 × 5 ÷ 65535) = 3.459068 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #08 voltage CAMRYH_HVBAT_C08_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Bits 112 to 127 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #09 voltage CAMRYH_HVBAT_C09_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 128 to 143 of the reply, 16 bits.
0xB0DB = 45275 → (45275 × 5 ÷ 65535) = 3.454261 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #10 voltage CAMRYH_HVBAT_C10_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 144 to 159 of the reply, 16 bits.
0xB10A = 45322 → (45322 × 5 ÷ 65535) = 3.457847 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #11 voltage CAMRYH_HVBAT_C11_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 160 to 175 of the reply, 16 bits.
0xB10A = 45322 → (45322 × 5 ÷ 65535) = 3.457847 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #12 voltage CAMRYH_HVBAT_C12_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #13 voltage CAMRYH_HVBAT_C13_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 192 to 207 of the reply, 16 bits.
0xB0DB = 45275 → (45275 × 5 ÷ 65535) = 3.454261 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #14 voltage CAMRYH_HVBAT_C14_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 208 to 223 of the reply, 16 bits.
0xB11A = 45338 → (45338 × 5 ÷ 65535) = 3.459068 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #15 voltage CAMRYH_HVBAT_C15_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Bits 224 to 239 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #16 voltage CAMRYH_HVBAT_C16_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 240 to 255 of the reply, 16 bits.
0xB11A = 45338 → (45338 × 5 ÷ 65535) = 3.459068 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #17 voltage CAMRYH_HVBAT_C17_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Bits 256 to 271 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #18 voltage CAMRYH_HVBAT_C18_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Bits 272 to 287 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #19 voltage CAMRYH_HVBAT_C19_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Bits 288 to 303 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #20 voltage CAMRYH_HVBAT_C20_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 304 to 319 of the reply, 16 bits.
0xB11A = 45338 → (45338 × 5 ÷ 65535) = 3.459068 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #21 voltage CAMRYH_HVBAT_C21_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 320 to 335 of the reply, 16 bits.
0xB11A = 45338 → (45338 × 5 ÷ 65535) = 3.459068 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #22 voltage CAMRYH_HVBAT_C22_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 336 to 351 of the reply, 16 bits.
0xB13A = 45370 → (45370 × 5 ÷ 65535) = 3.461509 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #23 voltage CAMRYH_HVBAT_C23_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Bits 352 to 367 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #24 voltage CAMRYH_HVBAT_C24_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Bits 368 to 383 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #25 voltage CAMRYH_HVBAT_C25_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Bits 384 to 399 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #26 voltage CAMRYH_HVBAT_C26_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Bits 400 to 415 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #27 voltage CAMRYH_HVBAT_C27_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Bits 416 to 431 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #28 voltage CAMRYH_HVBAT_C28_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Bits 432 to 447 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #29 voltage CAMRYH_HVBAT_C29_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 448 to 463 of the reply, 16 bits.
0xB0AA = 45226 → (45226 × 5 ÷ 65535) = 3.450523 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #30 voltage CAMRYH_HVBAT_C30_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Bits 464 to 479 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #31 voltage CAMRYH_HVBAT_C31_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Bits 480 to 495 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #32 voltage CAMRYH_HVBAT_C32_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 496 to 511 of the reply, 16 bits.
0xB10A = 45322 → (45322 × 5 ÷ 65535) = 3.457847 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #33 voltage CAMRYH_HVBAT_C33_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 512 to 527 of the reply, 16 bits.
0xB11A = 45338 → (45338 × 5 ÷ 65535) = 3.459068 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #34 voltage CAMRYH_HVBAT_C34_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Bits 528 to 543 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #35 voltage CAMRYH_HVBAT_C35_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Bits 544 to 559 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #36 voltage CAMRYH_HVBAT_C36_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 560 to 575 of the reply, 16 bits.
0xB14A = 45386 → (45386 × 5 ÷ 65535) = 3.46273 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #37 voltage CAMRYH_HVBAT_C37_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 576 to 591 of the reply, 16 bits.
0xB18A = 45450 → (45450 × 5 ÷ 65535) = 3.467613 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #38 voltage CAMRYH_HVBAT_C38_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 592 to 607 of the reply, 16 bits.
0xB17B = 45435 → (45435 × 5 ÷ 65535) = 3.466468 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #39 voltage CAMRYH_HVBAT_C39_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 608 to 623 of the reply, 16 bits.
0xB17B = 45435 → (45435 × 5 ÷ 65535) = 3.466468 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #40 voltage CAMRYH_HVBAT_C40_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 624 to 639 of the reply, 16 bits.
0xB15A = 45402 → (45402 × 5 ÷ 65535) = 3.463951 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #41 voltage CAMRYH_HVBAT_C41_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 640 to 655 of the reply, 16 bits.
0xB16A = 45418 → (45418 × 5 ÷ 65535) = 3.465171 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #42 voltage CAMRYH_HVBAT_C42_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 656 to 671 of the reply, 16 bits.
0xB17B = 45435 → (45435 × 5 ÷ 65535) = 3.466468 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #43 voltage CAMRYH_HVBAT_C43_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 672 to 687 of the reply, 16 bits.
0xB13A = 45370 → (45370 × 5 ÷ 65535) = 3.461509 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #44 voltage CAMRYH_HVBAT_C44_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 688 to 703 of the reply, 16 bits.
0xB13A = 45370 → (45370 × 5 ÷ 65535) = 3.461509 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #45 voltage CAMRYH_HVBAT_C45_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 704 to 719 of the reply, 16 bits.
0xB14A = 45386 → (45386 × 5 ÷ 65535) = 3.46273 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #46 voltage CAMRYH_HVBAT_C46_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 720 to 735 of the reply, 16 bits.
0xB14A = 45386 → (45386 × 5 ÷ 65535) = 3.46273 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #47 voltage CAMRYH_HVBAT_C47_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Bits 736 to 751 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #48 voltage CAMRYH_HVBAT_C48_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Bits 752 to 767 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #49 voltage CAMRYH_HVBAT_C49_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 768 to 783 of the reply, 16 bits.
0xB0DB = 45275 → (45275 × 5 ÷ 65535) = 3.454261 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #50 voltage CAMRYH_HVBAT_C50_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 784 to 799 of the reply, 16 bits.
0xB10A = 45322 → (45322 × 5 ÷ 65535) = 3.457847 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #51 voltage CAMRYH_HVBAT_C51_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Bits 800 to 815 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #52 voltage CAMRYH_HVBAT_C52_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Bits 816 to 831 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #53 voltage CAMRYH_HVBAT_C53_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Bits 832 to 847 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #54 voltage CAMRYH_HVBAT_C54_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Bits 848 to 863 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #55 voltage CAMRYH_HVBAT_C55_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 864 to 879 of the reply, 16 bits.
0xB13A = 45370 → (45370 × 5 ÷ 65535) = 3.461509 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #56 voltage CAMRYH_HVBAT_C56_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 880 to 895 of the reply, 16 bits.
0xB10A = 45322 → (45322 × 5 ÷ 65535) = 3.457847 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #57 voltage CAMRYH_HVBAT_C57_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 896 to 911 of the reply, 16 bits.
0xB13A = 45370 → (45370 × 5 ÷ 65535) = 3.461509 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #58 voltage CAMRYH_HVBAT_C58_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 912 to 927 of the reply, 16 bits.
0xB13A = 45370 → (45370 × 5 ÷ 65535) = 3.461509 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #59 voltage CAMRYH_HVBAT_C59_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 928 to 943 of the reply, 16 bits.
0xB14A = 45386 → (45386 × 5 ÷ 65535) = 3.46273 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #60 voltage CAMRYH_HVBAT_C60_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Bits 944 to 959 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #61 voltage CAMRYH_HVBAT_C61_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 960 to 975 of the reply, 16 bits.
0xB11A = 45338 → (45338 × 5 ÷ 65535) = 3.459068 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #62 voltage CAMRYH_HVBAT_C62_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 976 to 991 of the reply, 16 bits.
0xB10A = 45322 → (45322 × 5 ÷ 65535) = 3.457847 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #63 voltage CAMRYH_HVBAT_C63_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 992 to 1,007 of the reply, 16 bits.
0xB13A = 45370 → (45370 × 5 ÷ 65535) = 3.461509 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #64 voltage CAMRYH_HVBAT_C64_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Bits 1,008 to 1,023 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #65 voltage CAMRYH_HVBAT_C65_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 1,024 to 1,039 of the reply, 16 bits.
0xB14A = 45386 → (45386 × 5 ÷ 65535) = 3.46273 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #66 voltage CAMRYH_HVBAT_C66_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 1,040 to 1,055 of the reply, 16 bits.
0xB15A = 45402 → (45402 × 5 ÷ 65535) = 3.463951 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #67 voltage CAMRYH_HVBAT_C67_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 1,056 to 1,071 of the reply, 16 bits.
0xB14A = 45386 → (45386 × 5 ÷ 65535) = 3.46273 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #68 voltage CAMRYH_HVBAT_C68_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Bits 1,072 to 1,087 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #69 voltage CAMRYH_HVBAT_C69_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 1,088 to 1,103 of the reply, 16 bits.
0xB13A = 45370 → (45370 × 5 ÷ 65535) = 3.461509 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #70 voltage CAMRYH_HVBAT_C70_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Example reply from a 2023 Toyota Camry Hybrid.
Bits 1,104 to 1,119 of the reply, 16 bits.
0xB15A = 45402 → (45402 × 5 ÷ 65535) = 3.463951 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2019, 2021 to 2023. In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #71 voltage CAMRYH_HVBAT_C71_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Bits 1,120 to 1,135 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #72 voltage CAMRYH_HVBAT_C72_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Bits 1,136 to 1,151 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #73 voltage CAMRYH_HVBAT_C73_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Bits 1,152 to 1,167 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #74 voltage CAMRYH_HVBAT_C74_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Bits 1,168 to 1,183 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #75 voltage CAMRYH_HVBAT_C75_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Bits 1,184 to 1,199 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #76 voltage CAMRYH_HVBAT_C76_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Bits 1,200 to 1,215 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #77 voltage CAMRYH_HVBAT_C77_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Bits 1,216 to 1,231 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #78 voltage CAMRYH_HVBAT_C78_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Bits 1,232 to 1,247 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #79 voltage CAMRYH_HVBAT_C79_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Bits 1,248 to 1,263 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #80 voltage CAMRYH_HVBAT_C80_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Bits 1,264 to 1,279 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #81 voltage CAMRYH_HVBAT_C81_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Bits 1,280 to 1,295 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #82 voltage CAMRYH_HVBAT_C82_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Bits 1,296 to 1,311 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #83 voltage CAMRYH_HVBAT_C83_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Bits 1,312 to 1,327 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #84 voltage CAMRYH_HVBAT_C84_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Bits 1,328 to 1,343 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #85 voltage CAMRYH_HVBAT_C85_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Bits 1,344 to 1,359 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #86 voltage CAMRYH_HVBAT_C86_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Bits 1,360 to 1,375 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #87 voltage CAMRYH_HVBAT_C87_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Bits 1,376 to 1,391 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #88 voltage CAMRYH_HVBAT_C88_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Bits 1,392 to 1,407 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #89 voltage CAMRYH_HVBAT_C89_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Bits 1,408 to 1,423 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #90 voltage CAMRYH_HVBAT_C90_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Bits 1,424 to 1,439 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #91 voltage CAMRYH_HVBAT_C91_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Bits 1,440 to 1,455 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #92 voltage CAMRYH_HVBAT_C92_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Bits 1,456 to 1,471 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #93 voltage CAMRYH_HVBAT_C93_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Bits 1,472 to 1,487 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #94 voltage CAMRYH_HVBAT_C94_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Bits 1,488 to 1,503 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #95 voltage CAMRYH_HVBAT_C95_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Bits 1,504 to 1,519 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.
HV battery cell #96 voltage CAMRYH_HVBAT_C96_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2007 to 2018, 2020, 2024 to 2026
Bits 1,520 to 1,535 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2007 to 2017, 2020, 2024, 2026. Not supported for 2018, 2025.