Battery parameters
The Toyota Hilux has 35 battery parameters.
● Confirmed◆ In testing○ Supported× Not supported
+BM voltage HILUX_BM_V
- Request
21 41 - Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 56 to 71 of the reply, 16 bits.
- Formula
(val × 5 ÷ 4096)- Range
- 0 to 79.998 V
- Unit
- V
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
1st turbocharger outlet pressure, control valve HILUX_1ST_TRUBOCHARGER_P
- Request
22 11 CD - Service 22
DID 11CD - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 300 kPa
- Unit
- kPa
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
2nd turbocharger outlet pressure HILUX_2ND_TRUBOCHARGER_OUTLET_P
- Request
22 11 AF - Service 22
DID 11AF - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 300 kPa
- Unit
- kPa
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
2nd turbocharger outlet pressure, control valve HILUX_2ND_TRUBOCHARGER_P
- Request
22 11 CD - Service 22
DID 11CD - Module
700 → 708 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 300 kPa
- Unit
- kPa
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
AFS voltage B1S1 HILUX_AFS_VOLTAGE_B1S1
- Request
21 04 - Service 21
PID 04 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val × 7.99 ÷ 65535)- Range
- 0 to 7.99 V
- Unit
- V
In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Aux. battery capacity after IG OFF HILUX_AUX_BAT_CAP_AFTER_IG_OFF
- Request
22 15 E8 - Service 22
DID 15E8 - Module
700 → 708 - Every
3600 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val − 128)- Range
- -128 to 127 Ah
- Unit
- Ah
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Aux. battery capacity after IG ON HILUX_AUX_BAT_CAP_AFTER_IG_ON
- Request
22 15 E8 - Service 22
DID 15E8 - Module
700 → 708 - Every
3600 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val − 128)- Range
- -128 to 127 Ah
- Unit
- Ah
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Battery current HILUX_BAT_CURRENT
- Request
21 42 - Service 21
PID 42 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 50 ÷ 13107 − 125)- Range
- -125 to 124.9 A
- Unit
- A
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Battery current HILUX_BAT_CURRENT_700
- Request
22 15 F7 - Service 22
DID 15F7 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 49 ÷ 12850 − 125)- Range
- -125 to 124.9 A
- Unit
- A
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Battery status of full charge HILUX_BAT_STAT_FULL_CHG
- Request
22 15 E5 - Service 22
DID 15E5 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 255 ÷ 2)- Range
- 0 to 32512.5 Ah
- Unit
- Ah
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Battery temperature HILUX_BAT_T
- Request
21 42 - Service 21
PID 42 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 6513.5 °C
- Unit
- °C
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Battery temperature HILUX_BAT_T_700
- Request
22 15 F8 - Service 22
DID 15F8 - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Battery temperature HILUX_BAT_T_700_2
- Request
22 1F F8 - Service 22
DID 1FF8 - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 9 ÷ 50 − 40)- Range
- -40 to 11756.3 °F
- Unit
- °F
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Battery voltage HILUX_12V_VConfirmed
Pelican can show this parameter as the starter battery voltage.
- Request
22 10 02 - Service 22
DID 1002 - Module
700 → 708 - Every
1 s - Testing for 1988 to 2021, 2023, 2025 to 2026
Example reply from a 2024 Toyota Hilux.
Bits 0 to 15 of the reply, 16 bits.
0x2490 = 9360 → (9360 × 12.207 ÷ 10000) = 11.425752 V
- Formula
(val × 12.207 ÷ 10000)- Range
- 0 to 15 V
- Unit
- V
Confirmed for 2022, 2024. In testing for 1988 to 2021, 2023, 2025 to 2026.
Battery voltage HILUX_BAT_VConfirmed
- Request
21 13 - Service 21
PID 13 - Module
7C0 → 7C8 - Every
5 s - Testing for 1988 to 2021, 2023 to 2026
Example reply from a 2022 Toyota Hilux.
Bits 0 to 7 of the reply, 8 bits.
0x88 = 136 → (136 ÷ 10) = 13.6 V
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
Confirmed for 2022. In testing for 1988 to 2021, 2023 to 2026.
Battery voltage HILUX_BATTERY_VOLTAGE
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Charge contactor current HILUX_SCC_SOLENOID_CURRENT
- Request
21 A3 - Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Charging integrated current of aux. battery HILUX_CHG_INTEGRATED
- Request
22 15 E8 - Service 22
DID 15E8 - Module
700 → 708 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729.5 Ah
- Unit
- Ah
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Request
01 42 - Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65535 V
- Unit
- V
Confirmed for 2018. Supported for 2013, 2021 to 2022, 2024 to 2025.
Dark current of battery HILUX_DARK_CURRENT_BAT
- Request
22 15 E7 - Service 22
DID 15E7 - Module
700 → 708 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Discharging integrated current of aux. battery HILUX_DISCHARGING
- Request
22 15 E8 - Service 22
DID 15E8 - Module
700 → 708 - Every
3600 s - Testing
Bits 32 to 63 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729.5 Ah
- Unit
- Ah
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Distance since last battery cable disconnection HILUX_12V_DISCONNECT_ODOConfirmed
- Request
22 10 6C - Service 22
DID 106C - Module
700 → 708 - Every
1 s - Testing for 1988 to 2021, 2023, 2025 to 2026
Example reply from a 2024 Toyota Hilux.
Bits 0 to 15 of the reply, 16 bits.
0x4649 = 17993 → 17,993 km
- Formula
val- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2022, 2024. In testing for 1988 to 2021, 2023, 2025 to 2026.
Initial engine battery voltage lower limit HILUX_INITIAL_ENG_BAT_V_LO
- Request
22 15 F6 - Service 22
DID 15F6 - Module
700 → 708 - Every
3600 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Main connector solenoid current HILUX_SMC_SOLENOID_CURRENT
- Request
21 A3 - Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Main relay a, solenoid current HILUX_SLA_SOLENOID_CURRENT
- Request
21 A3 - Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Main relay r solenoid current HILUX_SLR_SOLENOID_CURRENT
- Request
21 A3 - Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Output speed sensor voltage HILUX_NOUT_SENS_V
- Request
21 81 - Service 21
PID 81 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
(val ÷ 13107)- Range
- 0 to 4.999 V
- Unit
- V
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Regenerative braking cooperation HILUX_REGEN_COOPERATION
- Request
21 58 - Service 21
PID 58 - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Regenerative operation HILUX_FR_REGEN_OPERATION
- Request
21 48 - Service 21
PID 48 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Regenerative request HILUX_FR_REGEN_REQUEST
- Request
21 48 - Service 21
PID 48 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Relay control solenoid current HILUX_SRC_SOLENOID_CURRENT
- Request
21 A3 - Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Service contactor solenoid current HILUX_SSC_SOLENOID_CURRENT
- Request
21 A3 - Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Sleep time of battery sensor HILUX_SLEEP_TIME_BATSENS
- Request
22 15 F0 - Service 22
DID 15F0 - Module
700 → 708 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 h
- Unit
- h
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Turbine speed sensor voltage HILUX_NT_SENS_V
- Request
21 81 - Service 21
PID 81 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 13107)- Range
- 0 to 4.999 V
- Unit
- V
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Voltage of battery sensor HILUX_V_BATSENS
- Request
22 15 EE - Service 22
DID 15EE - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 13333 ÷ 10922500)- Range
- 0 to 79.9979 V
- Unit
- V
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.