Battery parameters
The Toyota Land Cruiser has 177 battery parameters.
● Confirmed◆ In testing○ Supported× Not supported
+BM voltage LANDCRUISER_BM_V
- Request
21 41 - Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 56 to 71 of the reply, 16 bits.
- Formula
(val × 5 ÷ 4096)- Range
- 0 to 79.998 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
1st turbocharger outlet pressure, control valve LANDCRUISER_1ST_TRUBOCHARGER_P
- Request
22 11 CD - Service 22
DID 11CD - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 300 kPa
- Unit
- kPa
In testing for 1988 to 2024, 2026. Not supported for 2025.
2nd turbocharger outlet pressure LANDCRUISER_2ND_TRUBOCHARGER_OUTLET_P
- Request
22 11 AF - Service 22
DID 11AF - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 300 kPa
- Unit
- kPa
In testing for 1988 to 2024, 2026. Not supported for 2025.
2nd turbocharger outlet pressure, control valve LANDCRUISER_2ND_TRUBOCHARGER_P
- Request
22 11 CD - Service 22
DID 11CD - Module
700 → 708 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 300 kPa
- Unit
- kPa
In testing for 1988 to 2024, 2026. Not supported for 2025.
12V battery current LANDCRUISER_12V_CConfirmed
- Request
22 15 F7 - Service 22
DID 15F7 - Module
7D2 → 7DA - Every
500 ms - Testing for 1988 to 2024, 2026
Example reply from a 2025 Toyota Land Cruiser.
Bits 0 to 15 of the reply, 16 bits.
0x85E7 = 34279 → (34279 × 38.147 ÷ 10000 − 125) = 5.764101 A
- Formula
(val × 38.147 ÷ 10000 − 125)- Range
- -125 to 124 A
- Unit
- A
Confirmed for 2025. In testing for 1988 to 2024, 2026.
12V battery temperature LANDCRUISER_12V_TConfirmed
- Request
22 15 F8 - Service 22
DID 15F8 - Module
7D2 → 7DA - Every
1 s - Testing for 1988 to 2024, 2026
Example reply from a 2025 Toyota Land Cruiser.
Bits 0 to 15 of the reply, 16 bits.
0x0231 = 561 → (561 ÷ 10 − 40) = 16.1 °C
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
Confirmed for 2025. In testing for 1988 to 2024, 2026.
12V battery voltage LANDCRUISER_12V_V_7D2Confirmed
Pelican can show this parameter as the starter battery voltage.
- Request
22 15 EE - Service 22
DID 15EE - Module
7D2 → 7DA - Every
1 s - Testing for 1988 to 2024, 2026
Example reply from a 2025 Toyota Land Cruiser.
Bits 0 to 7 of the reply, 8 bits.
0x2D = 45 → (45 × 0.31448 + 0.0125) = 14.1641 V
- Formula
(val × 0.31448 + 0.0125)- Range
- 0 to 80.2 V
- Unit
- V
Confirmed for 2025. In testing for 1988 to 2024, 2026.
Accumulated time of battery low LANDCRUISER_ACCUMULATED_TIME_BAT
- Request
21 92 - Service 21
PID 92 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 56 to 71 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1988 to 2024, 2026. Not supported for 2025.
Accumulated time of battery too high LANDCRUISER_ACCUMULATED_TIME_BAT_TOO
- Request
21 92 - Service 21
PID 92 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 88 to 103 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1988 to 2024, 2026. Not supported for 2025.
Air fuel sensor voltage, bank 1 sensor 1 LANDCRUISER_AFS_VOLTAGE_B1S1
- Request
21 04 - Service 21
PID 04 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val × 7.99 ÷ 65535)- Range
- 0 to 7.99 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
Aux battery voltage LANDCRUISER_AUX_BAT_VConfirmed
- Request
22 10 02 - Service 22
DID 1002 - Module
7D2 → 7DA - Every
5 s - Testing for 1988 to 2024, 2026
Example reply from a 2025 Toyota Land Cruiser.
Bits 0 to 15 of the reply, 16 bits.
0x2D5C = 11612 → (11612 × 61 ÷ 50000) = 14.16664 V
- Formula
(val × 61 ÷ 50000)- Range
- 0 to 79.95 V
- Unit
- V
Confirmed for 2025. In testing for 1988 to 2024, 2026.
Aux. battery capacity after IG OFF LANDCRUISER_AUX_BAT_CAP_AFTER_IG_OFF
- Request
22 15 E8 - Service 22
DID 15E8 - Module
700 → 708 - Every
30 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val − 128)- Range
- -128 to 127 Ah
- Unit
- Ah
In testing for 1988 to 2024, 2026. Not supported for 2025.
Aux. battery capacity after IG ON LANDCRUISER_AUX_BAT_CAP_AFTER_IG_ON
- Request
22 15 E8 - Service 22
DID 15E8 - Module
700 → 708 - Every
30 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val − 128)- Range
- -128 to 127 Ah
- Unit
- Ah
In testing for 1988 to 2024, 2026. Not supported for 2025.
Auxiliary battery current LANDCRUISER_AUXILIARY_BATConfirmed
- Request
22 18 02 - Service 22
DID 1802 - Module
7D2 → 7DA - Every
1 s - Testing for 1988 to 2024, 2026
Example reply from a 2025 Toyota Land Cruiser.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → (0 × 2525 ÷ 13107 − 12500) = -12,500 A
- Formula
(val × 2525 ÷ 13107 − 12500)- Range
- -12500 to -12451 A
- Unit
- A
Confirmed for 2025. In testing for 1988 to 2024, 2026.
Auxiliary battery temperature LANDCRUISER_AUXILIARY_BAT_T
- Request
21 41 - Service 21
PID 41 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215
- Unit
- Number
In testing for 1988 to 2024, 2026. Not supported for 2025.
Auxiliary battery voltage LANDCRUISER_AUX_V
Pelican can show this parameter as the starter battery voltage.
- Request
21 CF - Service 21
PID CF - Module
7E3 → 7EB - Every
5 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val ÷ 5 − 25.6)- Range
- -25.6 to 25.4 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
Auxiliary battery voltage LANDCRUISER_AUXILIARY_BAT_V
- Request
21 81 - Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
(val × 47 ÷ 38550 − 40)- Range
- -40 to 39.9 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
Battery block 1 voltage LANDCRUISER_BAT_BLOCK_V_V01
- Request
21 81 - Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0012205692)- Range
- 0 to 79.99 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
Battery block 1 voltage LANDCRUISER_BATTERY_BLOCK_VOL_V01
- Request
21 CE - Service 21
PID CE - Module
7E2 → 7EA - Every
1 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
Battery block 2 voltage LANDCRUISER_BAT_BLOCK_V_V02
- Request
21 81 - Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 0.0012205692)- Range
- 0 to 79.99 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
Battery block 2 voltage LANDCRUISER_BATTERY_BLOCK_VOL_V02
- Request
21 CE - Service 21
PID CE - Module
7E2 → 7EA - Every
1 s - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
Battery block 3 voltage LANDCRUISER_BAT_BLOCK_V_V03
- Request
21 81 - Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val × 0.0012205692)- Range
- 0 to 79.99 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
Battery block 3 voltage LANDCRUISER_BATTERY_BLOCK_VOL_V03
- Request
21 CE - Service 21
PID CE - Module
7E2 → 7EA - Every
1 s - Testing
Bits 56 to 71 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
Battery block 4 voltage LANDCRUISER_BAT_BLOCK_V_V04
- Request
21 81 - Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val × 0.0012205692)- Range
- 0 to 79.99 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
Battery block 4 voltage LANDCRUISER_BATTERY_BLOCK_VOL_V04
- Request
21 CE - Service 21
PID CE - Module
7E2 → 7EA - Every
1 s - Testing
Bits 72 to 87 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
Battery block 5 voltage LANDCRUISER_BAT_BLOCK_V_V05
- Request
21 81 - Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val × 0.0012205692)- Range
- 0 to 79.99 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
Battery block 5 voltage LANDCRUISER_BATTERY_BLOCK_VOL_V05
- Request
21 CE - Service 21
PID CE - Module
7E2 → 7EA - Every
1 s - Testing
Bits 88 to 103 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
Battery block 6 voltage LANDCRUISER_BAT_BLOCK_V_V06
- Request
21 81 - Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
(val × 0.0012205692)- Range
- 0 to 79.99 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
Battery block 6 voltage LANDCRUISER_BATTERY_BLOCK_VOL_V06
- Request
21 CE - Service 21
PID CE - Module
7E2 → 7EA - Every
1 s - Testing
Bits 104 to 119 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
Battery block 7 voltage LANDCRUISER_BAT_BLOCK_V_V07
- Request
21 81 - Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val × 0.0012205692)- Range
- 0 to 79.99 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
Battery block 7 voltage LANDCRUISER_BATTERY_BLOCK_VOL_V07
- Request
21 CE - Service 21
PID CE - Module
7E2 → 7EA - Every
1 s - Testing
Bits 120 to 135 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
Battery block 8 voltage LANDCRUISER_BAT_BLOCK_V_V08
- Request
21 81 - Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
(val × 0.0012205692)- Range
- 0 to 79.99 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
Battery block 8 voltage LANDCRUISER_BATTERY_BLOCK_VOL_V08
- Request
21 CE - Service 21
PID CE - Module
7E2 → 7EA - Every
1 s - Testing
Bits 136 to 151 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
Battery block 9 voltage LANDCRUISER_BAT_BLOCK_V_V09
- Request
21 81 - Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
(val × 0.0012205692)- Range
- 0 to 79.99 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
Battery block 9 voltage LANDCRUISER_BATTERY_BLOCK_VOL_V09
- Request
21 CE - Service 21
PID CE - Module
7E2 → 7EA - Every
1 s - Testing
Bits 152 to 167 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
Battery block 10 voltage LANDCRUISER_BATTERY_BLOCK_VOL_V10
- Request
21 CE - Service 21
PID CE - Module
7E2 → 7EA - Every
1 s - Testing
Bits 168 to 183 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
Battery block 10 voltage, raw count LANDCRUISER_BAT_BLOCK_V_V10_RAW
- Request
21 81 - Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
(val × 7999 ÷ 6553500)- Range
- 0 to 79.99
- Unit
- Number
In testing for 1988 to 2024, 2026. Not supported for 2025.
Battery block 11 voltage LANDCRUISER_BAT_BLOCK_V_V11
- Request
21 81 - Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
(val × 0.0012205692)- Range
- 0 to 79.99 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
Battery block 11 voltage LANDCRUISER_BATTERY_BLOCK_VOL_V11
- Request
21 CE - Service 21
PID CE - Module
7E2 → 7EA - Every
1 s - Testing
Bits 184 to 199 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
Battery block 12 voltage LANDCRUISER_BAT_BLOCK_V_V12
- Request
21 81 - Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val × 0.0012205692)- Range
- 0 to 79.99 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
Battery block 12 voltage LANDCRUISER_BATTERY_BLOCK_VOL_V12
- Request
21 CE - Service 21
PID CE - Module
7E2 → 7EA - Every
1 s - Testing
Bits 200 to 215 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
Battery block 13 voltage LANDCRUISER_BAT_BLOCK_V_V13
- Request
21 81 - Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
(val × 0.0012205692)- Range
- 0 to 79.99 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
Battery block 13 voltage LANDCRUISER_BATTERY_BLOCK_VOL_V13
- Request
21 CE - Service 21
PID CE - Module
7E2 → 7EA - Every
1 s - Testing
Bits 216 to 231 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
Battery block 14 voltage LANDCRUISER_BAT_BLOCK_V_V14
- Request
21 81 - Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
(val × 0.0012205692)- Range
- 0 to 79.99 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
Battery block 14 voltage LANDCRUISER_BATTERY_BLOCK_VOL_V14
- Request
21 CE - Service 21
PID CE - Module
7E2 → 7EA - Every
1 s - Testing
Bits 232 to 247 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
Battery block 15 voltage LANDCRUISER_BATTERY_BLOCK_VOL_V15
- Request
21 CE - Service 21
PID CE - Module
7E2 → 7EA - Every
1 s - Testing
Bits 248 to 263 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
Battery block 16 voltage LANDCRUISER_BAT_BLOCK_V_V16
- Request
21 81 - Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
Battery block 17 voltage LANDCRUISER_BAT_BLOCK_V_V17
- Request
21 81 - Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 256 to 271 of the reply, 16 bits.
- Formula
(val × 7999 ÷ 6553500)- Range
- 0 to 79.99 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
Battery block number with, maximum voltage LANDCRUISER_BAT_BLOCK_NUMBER_MAX_V
- Request
21 92 - Service 21
PID 92 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val + 1)- Range
- 0 to 256
- Unit
- Number
In testing for 1988 to 2024, 2026. Not supported for 2025.
Battery block number with, minimum voltage LANDCRUISER_BAT_BLOCK_NUMBER_MIN_V
- Request
21 92 - Service 21
PID 92 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val + 1)- Range
- 0 to 256
- Unit
- Number
In testing for 1988 to 2024, 2026. Not supported for 2025.
Battery block, maximum voltage LANDCRUISER_BAT_BLOCK_MAX_V
- Request
21 92 - Service 21
PID 92 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
(val × 0.0012205692)- Range
- 0 to 79.99 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
Battery block, minimum voltage LANDCRUISER_BAT_BLOCK_MIN_V
- Request
21 92 - Service 21
PID 92 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0012205692)- Range
- 0 to 79.99 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
Battery current LANDCRUISER_BAT_CURRENT
- Request
21 42 - Service 21
PID 42 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 50 ÷ 13107 − 125)- Range
- -125 to 124.9 A
- Unit
- A
In testing for 1988 to 2024, 2026. Not supported for 2025.
Battery current LANDCRUISER_BAT_CURRENT_700
- Request
22 15 F7 - Service 22
DID 15F7 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 49 ÷ 12850 − 125)- Range
- -125 to 124.9 A
- Unit
- A
In testing for 1988 to 2024, 2026. Not supported for 2025.
Battery status of full charge LANDCRUISER_BAT_STAT_FULL_CHG
- Request
22 15 E5 - Service 22
DID 15E5 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 255 ÷ 2)- Range
- 0 to 32512.5 Ah
- Unit
- Ah
In testing for 1988 to 2024, 2026. Not supported for 2025.
Battery temperature LANDCRUISER_BAT_T
- Request
21 42 - Service 21
PID 42 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 6513.5 °C
- Unit
- °C
In testing for 1988 to 2024, 2026. Not supported for 2025.
Battery temperature LANDCRUISER_BAT_T_700
- Request
22 15 F8 - Service 22
DID 15F8 - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 1988 to 2024, 2026. Not supported for 2025.
Battery temperature LANDCRUISER_BAT_T_700_2
- Request
22 1F F8 - Service 22
DID 1FF8 - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 9 ÷ 50 − 40)- Range
- -40 to 11756.3 °F
- Unit
- °F
In testing for 1988 to 2024, 2026. Not supported for 2025.
Battery voltage LANDCRUISER_12V_VConfirmed
Pelican can show this parameter as the starter battery voltage.
- Request
22 10 02 - Service 22
DID 1002 - Module
700 → 708 - Every
1 s - Testing for 1988 to 2024, 2026
Example reply from a 2025 Toyota Land Cruiser.
Bits 0 to 15 of the reply, 16 bits.
0x2BBC = 11196 → (11196 × 12.207 ÷ 10000) = 13.666957 V
- Formula
(val × 12.207 ÷ 10000)- Range
- 0 to 79 V
- Unit
- V
Confirmed for 2025. In testing for 1988 to 2024, 2026.
Battery voltage LANDCRUISER_BAT_V
- Request
21 13 - Service 21
PID 13 - Module
7C0 → 7C8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
Battery voltage LANDCRUISER_BATTERY_VOLTAGE
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
Boost converter carrier frequency LANDCRUISER_CONV_CARRIER
- Request
21 C4 - Service 21
PID C4 - Module
7E2 → 7EA - Every
250 ms - Testing
Bit 71 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2024, 2026. Not supported for 2025.
Boost converter gate LANDCRUISER_CONV_GATE
- Request
21 C4 - Service 21
PID C4 - Module
7E2 → 7EA - Every
250 ms - Testing
Bit 66 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2024, 2026. Not supported for 2025.
Boost converter input voltage LANDCRUISER_VL
- Request
21 C4 - Service 21
PID C4 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 2)- Range
- 0 to 510 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
Boost converter output voltage LANDCRUISER_VH
- Request
21 C4 - Service 21
PID C4 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 2)- Range
- 0 to 510 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
Boost converter pressure ratio LANDCRUISER_BOOST_RATIO
- Request
21 C4 - Service 21
PID C4 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val × 0.392)- Range
- 0 to 99.96 %
- Unit
- %
In testing for 1988 to 2024, 2026. Not supported for 2025.
Boost converter temperature LANDCRUISER_CONV_T
- Request
21 C4 - Service 21
PID C4 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 1988 to 2024, 2026. Not supported for 2025.
Charge contactor current LANDCRUISER_SCC_SOLENOID_CURRENT
- Request
21 A3 - Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
In testing for 1988 to 2024, 2026. Not supported for 2025.
Charging integrated current of aux. battery LANDCRUISER_CHG_INTEGRATED
- Request
22 15 E8 - Service 22
DID 15E8 - Module
700 → 708 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729.5 Ah
- Unit
- Ah
In testing for 1988 to 2024, 2026. Not supported for 2025.
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Request
01 42 - Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65535 V
- Unit
- V
Confirmed for 2010, 2016, 2019 to 2020. Supported for 2006, 2008, 2017, 2021 to 2025.
Dark current of battery LANDCRUISER_DARK_CURRENT_BAT
- Request
22 15 E7 - Service 22
DID 15E7 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 1988 to 2024, 2026. Not supported for 2025.
DC-DC converter high side voltage LANDCRUISER_DC_DC_CONV_HIGH_SIDE_V
- Request
22 11 1E - Service 22
DID 111E - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 1220703 ÷ 10000000)- Range
- 0 to 7999 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
DC-DC converter low side voltage LANDCRUISER_DC_DC_CONV_LOW_SIDE_V
- Request
22 11 1D - Service 22
DID 111D - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 1953 ÷ 25000)- Range
- 0 to 19.92 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
DC-DC converter, target voltage before charging LANDCRUISER_DC_DC_CONV_TGT_V
- Request
22 11 1F - Service 22
DID 111F - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 1220703 ÷ 10000000)- Range
- 0 to 7999 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
Delta SOC LANDCRUISER_DELTA_SOC
- Request
21 98 - Service 21
PID 98 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127 %
- Unit
- %
In testing for 1988 to 2024, 2026. Not supported for 2025.
Discharging integrated current of aux. battery LANDCRUISER_DISCHARGING
- Request
22 15 E8 - Service 22
DID 15E8 - Module
700 → 708 - Every
30 s - Testing
Bits 32 to 63 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729.5 Ah
- Unit
- Ah
In testing for 1988 to 2024, 2026. Not supported for 2025.
Distance since last battery cable disconnection LANDCRUISER_DIST_SINCE_BAT_DISCConfirmed
- Request
22 10 6C - Service 22
DID 106C - Module
700 → 708 - Every
1 s - Testing for 1988 to 2024, 2026
Example reply from a 2025 Toyota Land Cruiser.
Bits 0 to 15 of the reply, 16 bits.
0x1AAE = 6830 → 6,830 km
- Formula
val- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2025. In testing for 1988 to 2024, 2026.
Engine control module control mode, driving control mode=1,current sensor offset mode=2,external charge control mode=3,power supply end mode=4 LANDCRUISER_ENG_CTRL_MODULE_CTRL_1_2_3_4
- Request
21 9B - Service 21
PID 9B - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2024, 2026. Not supported for 2025.
High voltage battery charge control, kw LANDCRUISER_HVBAT_CHG_CTRL_KW
- Request
21 98 - Service 21
PID 98 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val ÷ 2 − 64)- Range
- -64 to 63.5
- Unit
- Number
In testing for 1988 to 2024, 2026. Not supported for 2025.
High voltage battery discharge control, kw LANDCRUISER_HVBAT_DCHG_CTRL_KW
- Request
21 98 - Service 21
PID 98 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val ÷ 2 − 64)- Range
- -64 to 63.5
- Unit
- Number
In testing for 1988 to 2024, 2026. Not supported for 2025.
High voltage battery intake air temperature LANDCRUISER_HVBAT_IAT
- Request
21 87 - Service 21
PID 87 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0039047837 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 1988 to 2024, 2026. Not supported for 2025.
HV battery block 1 internal resistance LANDCRUISER_HVBAT_BLOCK_1_R
- Request
21 D0 - Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mΩ
- Unit
- mΩ
In testing for 1988 to 2024, 2026. Not supported for 2025.
HV battery block 1 voltage LANDCRUISER_HVBAT_BLOCK_1_V
- Request
21 CE - Service 21
PID CE - Module
7E3 → 7EB - Every
1 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
HV battery block 2 internal resistance LANDCRUISER_HVBAT_BLOCK_2_R
- Request
21 D0 - Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mΩ
- Unit
- mΩ
In testing for 1988 to 2024, 2026. Not supported for 2025.
HV battery block 2 voltage LANDCRUISER_HVBAT_BLOCK_2_V
- Request
21 CE - Service 21
PID CE - Module
7E3 → 7EB - Every
1 s - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
HV battery block 3 internal resistance LANDCRUISER_HVBAT_BLOCK_3_R
- Request
21 D0 - Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mΩ
- Unit
- mΩ
In testing for 1988 to 2024, 2026. Not supported for 2025.
HV battery block 3 voltage LANDCRUISER_HVBAT_BLOCK_3_V
- Request
21 CE - Service 21
PID CE - Module
7E3 → 7EB - Every
1 s - Testing
Bits 56 to 71 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
HV battery block 4 internal resistance LANDCRUISER_HVBAT_BLOCK_4_R
- Request
21 D0 - Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 144 to 151 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mΩ
- Unit
- mΩ
In testing for 1988 to 2024, 2026. Not supported for 2025.
HV battery block 4 voltage LANDCRUISER_HVBAT_BLOCK_4_V
- Request
21 CE - Service 21
PID CE - Module
7E3 → 7EB - Every
1 s - Testing
Bits 72 to 87 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
HV battery block 5 internal resistance LANDCRUISER_HVBAT_BLOCK_5_R
- Request
21 D0 - Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 152 to 159 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mΩ
- Unit
- mΩ
In testing for 1988 to 2024, 2026. Not supported for 2025.
HV battery block 5 voltage LANDCRUISER_HVBAT_BLOCK_5_V
- Request
21 CE - Service 21
PID CE - Module
7E3 → 7EB - Every
1 s - Testing
Bits 88 to 103 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
HV battery block 6 internal resistance LANDCRUISER_HVBAT_BLOCK_6_R
- Request
21 D0 - Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 160 to 167 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mΩ
- Unit
- mΩ
In testing for 1988 to 2024, 2026. Not supported for 2025.
HV battery block 6 voltage LANDCRUISER_HVBAT_BLOCK_6_V
- Request
21 CE - Service 21
PID CE - Module
7E3 → 7EB - Every
1 s - Testing
Bits 104 to 119 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
HV battery block 7 internal resistance LANDCRUISER_HVBAT_BLOCK_7_R
- Request
21 D0 - Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mΩ
- Unit
- mΩ
In testing for 1988 to 2024, 2026. Not supported for 2025.
HV battery block 7 voltage LANDCRUISER_HVBAT_BLOCK_7_V
- Request
21 CE - Service 21
PID CE - Module
7E3 → 7EB - Every
1 s - Testing
Bits 120 to 135 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
HV battery block 8 internal resistance LANDCRUISER_HVBAT_BLOCK_8_R
- Request
21 D0 - Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mΩ
- Unit
- mΩ
In testing for 1988 to 2024, 2026. Not supported for 2025.
HV battery block 8 voltage LANDCRUISER_HVBAT_BLOCK_8_V
- Request
21 CE - Service 21
PID CE - Module
7E3 → 7EB - Every
1 s - Testing
Bits 136 to 151 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
HV battery block 9 internal resistance LANDCRUISER_HVBAT_BLOCK_9_R
- Request
21 D0 - Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mΩ
- Unit
- mΩ
In testing for 1988 to 2024, 2026. Not supported for 2025.
HV battery block 9 voltage LANDCRUISER_HVBAT_BLOCK_9_V
- Request
21 CE - Service 21
PID CE - Module
7E3 → 7EB - Every
1 s - Testing
Bits 152 to 167 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
HV battery block 10 internal resistance LANDCRUISER_HVBAT_BLOCK_10_R
- Request
21 D0 - Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mΩ
- Unit
- mΩ
In testing for 1988 to 2024, 2026. Not supported for 2025.
HV battery block 10 voltage LANDCRUISER_HVBAT_BLOCK_10_V
- Request
21 CE - Service 21
PID CE - Module
7E3 → 7EB - Every
1 s - Testing
Bits 168 to 183 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
HV battery block 11 internal resistance LANDCRUISER_HVBAT_BLOCK_11_R
- Request
21 D0 - Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 200 to 207 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mΩ
- Unit
- mΩ
In testing for 1988 to 2024, 2026. Not supported for 2025.
HV battery block 11 voltage LANDCRUISER_HVBAT_BLOCK_11_V
- Request
21 CE - Service 21
PID CE - Module
7E3 → 7EB - Every
1 s - Testing
Bits 184 to 199 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
HV battery block 12 internal resistance LANDCRUISER_HVBAT_BLOCK_12_R
- Request
21 D0 - Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 208 to 215 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mΩ
- Unit
- mΩ
In testing for 1988 to 2024, 2026. Not supported for 2025.
HV battery block 12 voltage LANDCRUISER_HVBAT_BLOCK_12_V
- Request
21 CE - Service 21
PID CE - Module
7E3 → 7EB - Every
1 s - Testing
Bits 200 to 215 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
HV battery block 13 internal resistance LANDCRUISER_HVBAT_BLOCK_13_R
- Request
21 D0 - Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 216 to 223 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mΩ
- Unit
- mΩ
In testing for 1988 to 2024, 2026. Not supported for 2025.
HV battery block 13 voltage LANDCRUISER_HVBAT_BLOCK_13_V
- Request
21 CE - Service 21
PID CE - Module
7E3 → 7EB - Every
1 s - Testing
Bits 216 to 231 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
HV battery block 14 internal resistance LANDCRUISER_HVBAT_BLOCK_14_R
- Request
21 D0 - Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 224 to 231 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mΩ
- Unit
- mΩ
In testing for 1988 to 2024, 2026. Not supported for 2025.
HV battery block 14 voltage LANDCRUISER_HVBAT_BLOCK_14_V
- Request
21 CE - Service 21
PID CE - Module
7E3 → 7EB - Every
1 s - Testing
Bits 232 to 247 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
HV battery block count LANDCRUISER_HVBAT_BLOCKS
- Request
21 D0 - Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2024, 2026. Not supported for 2025.
HV battery block voltage, highest LANDCRUISER_HVBAT_BLOCK_V_MAX
- Request
21 D0 - Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
HV battery block voltage, lowest LANDCRUISER_HVBAT_BLOCK_V_MIN
- Request
21 D0 - Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 72 to 87 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
HV battery block with the highest voltage LANDCRUISER_HVBAT_BLOCK_V_MAX_NO
- Request
21 D0 - Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2024, 2026. Not supported for 2025.
HV battery block with the lowest voltage LANDCRUISER_HVBAT_BLOCK_V_MIN_NO
- Request
21 D0 - Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2024, 2026. Not supported for 2025.
HV battery charge LANDCRUISER_HVBAT_SOC
Pelican can show this parameter as the state of charge.
- Request
21 CE - Service 21
PID CE - Module
7E3 → 7EB - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127.5 %
- Unit
- %
In testing for 1988 to 2024, 2026. Not supported for 2025.
HV battery charge power limit LANDCRUISER_HVBAT_CHG_LIM
- Request
21 CF - Service 21
PID CF - Module
7E3 → 7EB - Every
5 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val − 64)- Range
- -64 to 191 kW
- Unit
- kW
In testing for 1988 to 2024, 2026. Not supported for 2025.
HV battery charge spread LANDCRUISER_HVBAT_DELTA_SOC
- Request
21 CF - Service 21
PID CF - Module
7E3 → 7EB - Every
5 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val ÷ 100)- Range
- 0 to 2.55 %
- Unit
- %
In testing for 1988 to 2024, 2026. Not supported for 2025.
HV battery charge voltage LANDCRUISER_HVBAT_CHRG_V
- Request
22 16 09 - Service 22
DID 1609 - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 100 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
HV battery charge, displayed LANDCRUISER_HVBAT_SOC_DISPLAY
Pelican can show this parameter as the state of charge.
- Request
22 17 39 - Service 22
DID 1739 - Module
745 → 74D - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 1988 to 2007, 2009 to 2017, 2019 to 2024, 2026. Not supported for 2008, 2018, 2025.
HV battery charge, hybrid control LANDCRUISER_HV_SOC
- Request
21 C3 - Service 21
PID C3 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 144 to 151 of the reply, 8 bits.
- Formula
(val × 0.392)- Range
- 0 to 99.96 %
- Unit
- %
In testing for 1988 to 2024, 2026. Not supported for 2025.
HV battery charge, maximum LANDCRUISER_HVBAT_SOC_MAXConfirmed
- Request
22 10 6C - Service 22
DID 106C - Module
7D2 → 7DA - Every
5 s - Testing for 1988 to 2023, 2026
Example reply from a 2025 Toyota Land Cruiser.
Bits 8 to 15 of the reply, 8 bits.
0x4C = 76 → (76 ÷ 2) = 38 %
- Formula
(val ÷ 2)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024 to 2025. In testing for 1988 to 2007, 2009, 2011 to 2015, 2022, 2026. Not supported for 2008, 2010, 2016 to 2021, 2023.
HV battery charge, minimum LANDCRUISER_HVBAT_SOC_MINConfirmed
- Request
22 10 6C - Service 22
DID 106C - Module
7D2 → 7DA - Every
5 s - Testing for 1988 to 2023, 2026
Example reply from a 2025 Toyota Land Cruiser.
Bits 16 to 23 of the reply, 8 bits.
0x4C = 76 → (76 ÷ 2) = 38 %
- Formula
(val ÷ 2)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024 to 2025. In testing for 1988 to 2007, 2009, 2011 to 2015, 2022, 2026. Not supported for 2008, 2010, 2016 to 2021, 2023.
HV battery current LANDCRUISER_HVBAT_CConfirmed
- Request
22 1F 9A - Service 22
DID 1F9A - Module
7D2 → 7DA - Every
500 ms - Testing for 1988 to 2024, 2026
Example reply from a 2025 Toyota Land Cruiser.
Bits 32 to 47 of the reply, 16 bits. The value is signed.
0x0020 = 32 → (32 ÷ 10) = 3.2 A
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 A
- Unit
- A
Confirmed for 2025. In testing for 1988 to 2024, 2026.
HV battery current LANDCRUISER_HVBAT_I
Pelican can show this parameter as the traction battery current.
- Request
21 CE - Service 21
PID CE - Module
7E3 → 7EB - Every
1 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 A
- Unit
- A
In testing for 1988 to 2024, 2026. Not supported for 2025.
HV battery DC inhibit time LANDCRUISER_HVBAT_DC_INHIBIT_TIME
- Request
21 D0 - Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 s
- Unit
- s
In testing for 1988 to 2024, 2026. Not supported for 2025.
HV battery discharge power limit LANDCRUISER_HVBAT_DISCHG_LIM
- Request
21 CF - Service 21
PID CF - Module
7E3 → 7EB - Every
5 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val − 64)- Range
- -64 to 191 kW
- Unit
- kW
In testing for 1988 to 2024, 2026. Not supported for 2025.
HV battery discharge power limit LANDCRUISER_WOUT
- Request
21 C3 - Service 21
PID C3 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 152 to 159 of the reply, 8 bits.
- Formula
(val × 320)- Range
- 0 to 81600 W
- Unit
- W
In testing for 1988 to 2024, 2026. Not supported for 2025.
HV battery fan motor voltage LANDCRUISER_HVBAT_FAN_V
- Request
21 CF - Service 21
PID CF - Module
7E3 → 7EB - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val ÷ 5 − 25.6)- Range
- -25.6 to 25.4 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
HV battery fan speed LANDCRUISER_HVBAT_FAN
- Request
21 CF - Service 21
PID CF - Module
7E3 → 7EB - Every
5 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2024, 2026. Not supported for 2025.
HV battery high charge time LANDCRUISER_HVBAT_HIGH_TIME
- Request
21 D0 - Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 s
- Unit
- s
In testing for 1988 to 2024, 2026. Not supported for 2025.
HV battery hot temperature time LANDCRUISER_HVBAT_HOT_TIME
- Request
21 D0 - Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 56 to 71 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 s
- Unit
- s
In testing for 1988 to 2024, 2026. Not supported for 2025.
HV battery intake air temperature LANDCRUISER_HVBAT_INTAKE_T
- Request
21 CF - Service 21
PID CF - Module
7E3 → 7EB - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 °C
- Unit
- °C
In testing for 1988 to 2024, 2026. Not supported for 2025.
HV battery low charge time LANDCRUISER_HVBAT_LOW_TIME
- Request
21 D0 - Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 s
- Unit
- s
In testing for 1988 to 2024, 2026. Not supported for 2025.
HV battery maximum temperature LANDCRUISER_HVBAT_MAX_T
- Request
22 18 29 - Service 22
DID 1829 - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 1988 to 2024, 2026. Not supported for 2025.
HV battery minimum temperature LANDCRUISER_HVBAT_MIN_T
- Request
22 18 2A - Service 22
DID 182A - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 1988 to 2024, 2026. Not supported for 2025.
HV battery temperature 1 LANDCRUISER_HVBAT_T_1
- Request
21 CF - Service 21
PID CF - Module
7E3 → 7EB - Every
5 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 °C
- Unit
- °C
In testing for 1988 to 2024, 2026. Not supported for 2025.
HV battery temperature 2 LANDCRUISER_HVBAT_T_2
- Request
21 CF - Service 21
PID CF - Module
7E3 → 7EB - Every
5 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 °C
- Unit
- °C
In testing for 1988 to 2024, 2026. Not supported for 2025.
HV battery temperature 3 LANDCRUISER_HVBAT_T_3
- Request
21 CF - Service 21
PID CF - Module
7E3 → 7EB - Every
5 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 °C
- Unit
- °C
In testing for 1988 to 2024, 2026. Not supported for 2025.
HV battery voltage LANDCRUISER_HVBAT_VConfirmed
- Request
22 1F 9A - Service 22
DID 1F9A - Module
7D2 → 7DA - Every
500 ms - Testing for 1988 to 2024, 2026
Example reply from a 2025 Toyota Land Cruiser.
Bits 16 to 31 of the reply, 16 bits.
0x4B00 = 19200 → (19200 × 156.25 ÷ 10000) = 300 V
- Formula
(val × 156.25 ÷ 10000)- Range
- 0 to 1023 V
- Unit
- V
Confirmed for 2025. In testing for 1988 to 2024, 2026.
Hybrid battery 1 fan LANDCRUISER_HYBRID_BAT_1_FANConfirmed
- Request
22 18 02 - Service 22
DID 1802 - Module
7D2 → 7DA - Every
1 s - Testing for 1988 to 2024, 2026
Example reply from a 2025 Toyota Land Cruiser.
Bits 16 to 23 of the reply, 8 bits.
0x00 = 0 → (0 ÷ 2) = 0 %
- Formula
(val ÷ 2)- Range
- 0 to 127 %
- Unit
- %
Confirmed for 2025. In testing for 1988 to 2024, 2026.
Hybrid battery temperature 1 LANDCRUISER_HYBRID_BAT_T_1Confirmed
- Request
22 18 14 - Service 22
DID 1814 - Module
7D2 → 7DA - Every
5 s - Testing for 1988 to 2024, 2026
Example reply from a 2025 Toyota Land Cruiser.
Bits 0 to 15 of the reply, 16 bits.
0x4302 = 17154 → (17154 × 458 ÷ 65535 − 58) = 61.882994 °F
- Formula
(val × 458 ÷ 65535 − 58)- Range
- -58 to 400 °F
- Unit
- °F
Confirmed for 2025. In testing for 1988 to 2024, 2026.
Hybrid battery temperature 2 LANDCRUISER_HYBRID_BAT_T_2Confirmed
- Request
22 18 14 - Service 22
DID 1814 - Module
7D2 → 7DA - Every
5 s - Testing for 1988 to 2024, 2026
Example reply from a 2025 Toyota Land Cruiser.
Bits 16 to 23 of the reply, 8 bits.
0x43 = 67 → (67 × 9 ÷ 5 − 58) = 62.6 °F
- Formula
(val × 9 ÷ 5 − 58)- Range
- -58 to 401 °F
- Unit
- °F
Confirmed for 2025. In testing for 1988 to 2024, 2026.
Hybrid battery temperature 3 LANDCRUISER_HYBRID_BAT_T_3Confirmed
- Request
22 18 14 - Service 22
DID 1814 - Module
7D2 → 7DA - Every
5 s - Testing for 1988 to 2024, 2026
Example reply from a 2025 Toyota Land Cruiser.
Bits 32 to 47 of the reply, 16 bits.
0x4302 = 17154 → (17154 × 458 ÷ 65535 − 58) = 61.882994 °F
- Formula
(val × 458 ÷ 65535 − 58)- Range
- -58 to 400 °F
- Unit
- °F
Confirmed for 2025. In testing for 1988 to 2024, 2026.
Initial engine battery voltage lower limit LANDCRUISER_INITIAL_ENG_BAT_V_LO
- Request
22 15 F6 - Service 22
DID 15F6 - Module
700 → 708 - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
Input over-voltage to converter LANDCRUISER_OVERVOLTAGE_INPUT
- Request
21 74 - Service 21
PID 74 - Module
7E2 → 7EA - Every
1 s - Testing
Bit 33 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2024, 2026. Not supported for 2025.
Input over-voltage to inverter LANDCRUISER_OVERVOLTAGE_INPUT_INVERTER
- Request
21 74 - Service 21
PID 74 - Module
7E2 → 7EA - Every
1 s - Testing
Bit 34 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2024, 2026. Not supported for 2025.
Main battery charging requested LANDCRUISER_CHARGE_REQ
- Request
21 C4 - Service 21
PID C4 - Module
7E2 → 7EA - Every
250 ms - Testing
Bit 11 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2024, 2026. Not supported for 2025.
Main connector solenoid current LANDCRUISER_SMC_SOLENOID_CURRENT
- Request
21 A3 - Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
In testing for 1988 to 2024, 2026. Not supported for 2025.
Main relay a, solenoid current LANDCRUISER_SLA_SOLENOID_CURRENT
- Request
21 A3 - Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
In testing for 1988 to 2024, 2026. Not supported for 2025.
Main relay r solenoid current LANDCRUISER_SLR_SOLENOID_CURRENT
- Request
21 A3 - Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
In testing for 1988 to 2024, 2026. Not supported for 2025.
Number of battery blocks LANDCRUISER_NUM_BAT_BLOCKS
- Request
21 92 - Service 21
PID 92 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2024, 2026. Not supported for 2025.
Output speed sensor voltage LANDCRUISER_NOUT_SENS_V
- Request
21 81 - Service 21
PID 81 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
(val ÷ 13107)- Range
- 0 to 4.999 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
Power resource current LANDCRUISER_IB
- Request
21 C3 - Service 21
PID C3 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 240 to 247 of the reply, 8 bits.
- Formula
(val × 2 − 256)- Range
- -256 to 254 A
- Unit
- A
In testing for 1988 to 2024, 2026. Not supported for 2025.
Power resource voltage LANDCRUISER_VB
- Request
21 C3 - Service 21
PID C3 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 224 to 231 of the reply, 8 bits.
- Formula
(val × 2)- Range
- 0 to 510 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
Regen cooperation LANDCRUISER_REGEN_COOPERATION
- Request
21 58 - Service 21
PID 58 - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2024, 2026. Not supported for 2025.
Regenerative operation LANDCRUISER_FR_REGEN_OPERATION
- Request
21 48 - Service 21
PID 48 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 1988 to 2024, 2026. Not supported for 2025.
Regenerative request LANDCRUISER_FR_REGEN_REQUEST
- Request
21 48 - Service 21
PID 48 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 1988 to 2024, 2026. Not supported for 2025.
Relay control solenoid current LANDCRUISER_SRC_SOLENOID_CURRENT
- Request
21 A3 - Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
In testing for 1988 to 2024, 2026. Not supported for 2025.
Service contactor solenoid current LANDCRUISER_SSC_SOLENOID_CURRENT
- Request
21 A3 - Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
In testing for 1988 to 2024, 2026. Not supported for 2025.
Short circuit wave highest value LANDCRUISER_SHORT_WAVE_V
- Request
21 C4 - Service 21
PID C4 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val ÷ 51)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
Sleep time of battery sensor LANDCRUISER_SLEEP_TIME_BATSENS
- Request
22 15 F0 - Service 22
DID 15F0 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 h
- Unit
- h
In testing for 1988 to 2024, 2026. Not supported for 2025.
SOC at ignition on LANDCRUISER_SOC_AFTER_IG_ON
- Request
21 98 - Service 21
PID 98 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127 %
- Unit
- %
In testing for 1988 to 2024, 2026. Not supported for 2025.
SOC max LANDCRUISER_SOC_MAX
- Request
21 98 - Service 21
PID 98 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127 %
- Unit
- %
In testing for 1988 to 2024, 2026. Not supported for 2025.
SOC min LANDCRUISER_SOC_MIN
- Request
21 98 - Service 21
PID 98 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127 %
- Unit
- %
In testing for 1988 to 2024, 2026. Not supported for 2025.
State of charge LANDCRUISER_SOCConfirmed
Pelican can show this parameter as the state of charge.
- Request
22 1F 5B - Service 22
DID 1F5B - Module
7D2 → 7DA - Every
1 s - Testing for 1988 to 2024, 2026
Example reply from a 2025 Toyota Land Cruiser.
Bits 0 to 7 of the reply, 8 bits.
0x65 = 101 → (101 × 100 ÷ 255) = 39.607843 %
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2025. In testing for 1988 to 2007, 2009 to 2024, 2026. Not supported for 2008.
State of charge, all bat LANDCRUISER_ST_CHG_ALL_BAT
- Request
21 01 - Service 21
PID 01 - Module
7E2 → 7EA - Every
30 s - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 1988 to 2024, 2026. Not supported for 2025.
System main relay 1 LANDCRUISER_SMR1
- Request
21 C4 - Service 21
PID C4 - Module
7E2 → 7EA - Every
250 ms - Testing
Bit 63 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2024, 2026. Not supported for 2025.
System main relay 2 LANDCRUISER_SMR2
- Request
21 C4 - Service 21
PID C4 - Module
7E2 → 7EA - Every
250 ms - Testing
Bit 62 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2024, 2026. Not supported for 2025.
System main relay 3 LANDCRUISER_SMR3
- Request
21 C4 - Service 21
PID C4 - Module
7E2 → 7EA - Every
250 ms - Testing
Bit 61 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2024, 2026. Not supported for 2025.
Turbine speed sensor voltage LANDCRUISER_NT_SENS_V
- Request
21 81 - Service 21
PID 81 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 13107)- Range
- 0 to 4.999 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
Vh-voltage after boosting LANDCRUISER_VH_V_AFTER_BOOSTINGConfirmed
- Request
22 10 B0 - Service 22
DID 10B0 - Module
7D2 → 7DA - Every
1 s - Testing for 1988 to 2024, 2026
Example reply from a 2025 Toyota Land Cruiser.
Bits 16 to 31 of the reply, 16 bits.
0x025A = 602 → (602 ÷ 2) = 301 V
- Formula
(val ÷ 2)- Range
- 0 to 32767 V
- Unit
- V
Confirmed for 2025. In testing for 1988 to 2024, 2026.
Vh-voltage after boosting LANDCRUISER_VH_V_AFTER_BOOSTING_7E2
- Request
21 74 - Service 21
PID 74 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 56 to 71 of the reply, 16 bits.
- Formula
(val ÷ 2)- Range
- 0 to 32767 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
Vl-voltage before boosting LANDCRUISER_VL_V_BEFORE_BOOSTINGConfirmed
- Request
22 10 B0 - Service 22
DID 10B0 - Module
7D2 → 7DA - Every
1 s - Testing for 1988 to 2024, 2026
Example reply from a 2025 Toyota Land Cruiser.
Bits 0 to 15 of the reply, 16 bits.
0x025A = 602 → (602 ÷ 2) = 301 V
- Formula
(val ÷ 2)- Range
- 0 to 32767 V
- Unit
- V
Confirmed for 2025. In testing for 1988 to 2024, 2026.
Vl-voltage before boosting LANDCRUISER_VL_V_BEFORE_BOOSTING_7E2
- Request
21 74 - Service 21
PID 74 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
(val ÷ 2)- Range
- 0 to 32767 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
Voltage of battery sensor LANDCRUISER_V_BATSENS
- Request
22 15 EE - Service 22
DID 15EE - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 13333 ÷ 10922500)- Range
- 0 to 79.9979 V
- Unit
- V
In testing for 1988 to 2024, 2026. Not supported for 2025.
Battery › Modules › 01
HV battery module 01 voltage LANDCRUISER_HVBAT_CMU01_VOLT
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 13107)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2007, 2009 to 2017, 2019 to 2024, 2026. Not supported for 2008, 2018, 2025.
Battery › Modules › 02
HV battery module 02 voltage LANDCRUISER_HVBAT_CMU02_VOLT
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 13107)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2007, 2009 to 2017, 2019 to 2024, 2026. Not supported for 2008, 2018, 2025.