Battery parameters
The FIAT 500e has 261 battery parameters.
● Confirmed◆ In testing○ Supported× Not supported
12V battery voltage 500E_AUX_BAT_V
Pelican can show this parameter as the starter battery voltage.
- Request
22 A0 42 - Service 22
DID A042 - Module
DA44 → 44 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2012 to 2026.
Air heater voltage 500E_AIRHEATER_V
- Request
22 40 55 - Service 22
DID 4055 - Module
DA42 → 42 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 2020 to 2026.
Battery cell 01 state of charge 500E_BAT_CELL_01_ST_CHG
- Request
22 B0 04 - Service 22
DID B004 - Module
DA44 → 44 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 01 voltage 500E_BAT_CELL_01_V
- Request
22 A1 00 - Service 22
DID A100 - Module
DA44 → 44 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 02 state of charge 500E_BAT_CELL_02_ST_CHG
- Request
22 B0 04 - Service 22
DID B004 - Module
DA44 → 44 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 02 voltage 500E_BAT_CELL_02_V
- Request
22 A1 00 - Service 22
DID A100 - Module
DA44 → 44 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 03 state of charge 500E_BAT_CELL_03_ST_CHG
- Request
22 B0 04 - Service 22
DID B004 - Module
DA44 → 44 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 03 voltage 500E_BAT_CELL_03_V
- Request
22 A1 00 - Service 22
DID A100 - Module
DA44 → 44 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 04 state of charge 500E_BAT_CELL_04_ST_CHG
- Request
22 B0 04 - Service 22
DID B004 - Module
DA44 → 44 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 04 voltage 500E_BAT_CELL_04_V
- Request
22 A1 00 - Service 22
DID A100 - Module
DA44 → 44 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 05 state of charge 500E_BAT_CELL_05_ST_CHG
- Request
22 B0 04 - Service 22
DID B004 - Module
DA44 → 44 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 05 voltage 500E_BAT_CELL_05_V
- Request
22 A1 00 - Service 22
DID A100 - Module
DA44 → 44 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 06 state of charge 500E_BAT_CELL_06_ST_CHG
- Request
22 B0 04 - Service 22
DID B004 - Module
DA44 → 44 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 06 voltage 500E_BAT_CELL_06_V
- Request
22 A1 00 - Service 22
DID A100 - Module
DA44 → 44 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 07 state of charge 500E_BAT_CELL_07_ST_CHG
- Request
22 B0 04 - Service 22
DID B004 - Module
DA44 → 44 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 07 voltage 500E_BAT_CELL_07_V
- Request
22 A1 00 - Service 22
DID A100 - Module
DA44 → 44 - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 08 state of charge 500E_BAT_CELL_08_ST_CHG
- Request
22 B0 04 - Service 22
DID B004 - Module
DA44 → 44 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 08 voltage 500E_BAT_CELL_08_V
- Request
22 A1 00 - Service 22
DID A100 - Module
DA44 → 44 - Every
1 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 09 state of charge 500E_BAT_CELL_09_ST_CHG
- Request
22 B0 04 - Service 22
DID B004 - Module
DA44 → 44 - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 09 voltage 500E_BAT_CELL_09_V
- Request
22 A1 00 - Service 22
DID A100 - Module
DA44 → 44 - Every
1 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 10 state of charge 500E_BAT_CELL_10_ST_CHG
- Request
22 B0 04 - Service 22
DID B004 - Module
DA44 → 44 - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 10 voltage 500E_BAT_CELL_10_V
- Request
22 A1 00 - Service 22
DID A100 - Module
DA44 → 44 - Every
1 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 11 state of charge 500E_BAT_CELL_11_ST_CHG
- Request
22 B0 04 - Service 22
DID B004 - Module
DA44 → 44 - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 11 voltage 500E_BAT_CELL_11_V
- Request
22 A1 00 - Service 22
DID A100 - Module
DA44 → 44 - Every
1 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 12 state of charge 500E_BAT_CELL_12_ST_CHG
- Request
22 B0 04 - Service 22
DID B004 - Module
DA44 → 44 - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 12 voltage 500E_BAT_CELL_12_V
- Request
22 A1 00 - Service 22
DID A100 - Module
DA44 → 44 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 13 state of charge 500E_BAT_CELL_13_ST_CHG
- Request
22 B0 05 - Service 22
DID B005 - Module
DA44 → 44 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 13 voltage 500E_BAT_CELL_13_V
- Request
22 A1 01 - Service 22
DID A101 - Module
DA44 → 44 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 14 state of charge 500E_BAT_CELL_14_ST_CHG
- Request
22 B0 05 - Service 22
DID B005 - Module
DA44 → 44 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 14 voltage 500E_BAT_CELL_14_V
- Request
22 A1 01 - Service 22
DID A101 - Module
DA44 → 44 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 15 state of charge 500E_BAT_CELL_15_ST_CHG
- Request
22 B0 05 - Service 22
DID B005 - Module
DA44 → 44 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 15 voltage 500E_BAT_CELL_15_V
- Request
22 A1 01 - Service 22
DID A101 - Module
DA44 → 44 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 16 state of charge 500E_BAT_CELL_16_ST_CHG
- Request
22 B0 05 - Service 22
DID B005 - Module
DA44 → 44 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 16 voltage 500E_BAT_CELL_16_V
- Request
22 A1 01 - Service 22
DID A101 - Module
DA44 → 44 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 17 state of charge 500E_BAT_CELL_17_ST_CHG
- Request
22 B0 05 - Service 22
DID B005 - Module
DA44 → 44 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 17 voltage 500E_BAT_CELL_17_V
- Request
22 A1 01 - Service 22
DID A101 - Module
DA44 → 44 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 18 state of charge 500E_BAT_CELL_18_ST_CHG
- Request
22 B0 05 - Service 22
DID B005 - Module
DA44 → 44 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 18 voltage 500E_BAT_CELL_18_V
- Request
22 A1 01 - Service 22
DID A101 - Module
DA44 → 44 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 19 state of charge 500E_BAT_CELL_19_ST_CHG
- Request
22 B0 05 - Service 22
DID B005 - Module
DA44 → 44 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 19 voltage 500E_BAT_CELL_19_V
- Request
22 A1 01 - Service 22
DID A101 - Module
DA44 → 44 - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 20 state of charge 500E_BAT_CELL_20_ST_CHG
- Request
22 B0 05 - Service 22
DID B005 - Module
DA44 → 44 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 20 voltage 500E_BAT_CELL_20_V
- Request
22 A1 01 - Service 22
DID A101 - Module
DA44 → 44 - Every
1 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 21 state of charge 500E_BAT_CELL_21_ST_CHG
- Request
22 B0 05 - Service 22
DID B005 - Module
DA44 → 44 - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 21 voltage 500E_BAT_CELL_21_V
- Request
22 A1 01 - Service 22
DID A101 - Module
DA44 → 44 - Every
1 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 22 state of charge 500E_BAT_CELL_22_ST_CHG
- Request
22 B0 05 - Service 22
DID B005 - Module
DA44 → 44 - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 22 voltage 500E_BAT_CELL_22_V
- Request
22 A1 01 - Service 22
DID A101 - Module
DA44 → 44 - Every
1 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 23 state of charge 500E_BAT_CELL_23_ST_CHG
- Request
22 B0 05 - Service 22
DID B005 - Module
DA44 → 44 - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 23 voltage 500E_BAT_CELL_23_V
- Request
22 A1 01 - Service 22
DID A101 - Module
DA44 → 44 - Every
1 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 24 state of charge 500E_BAT_CELL_24_ST_CHG
- Request
22 B0 05 - Service 22
DID B005 - Module
DA44 → 44 - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 24 voltage 500E_BAT_CELL_24_V
- Request
22 A1 01 - Service 22
DID A101 - Module
DA44 → 44 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 25 state of charge 500E_BAT_CELL_25_ST_CHG
- Request
22 B0 06 - Service 22
DID B006 - Module
DA44 → 44 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 25 voltage 500E_BAT_CELL_25_V
- Request
22 A1 02 - Service 22
DID A102 - Module
DA44 → 44 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 26 state of charge 500E_BAT_CELL_26_ST_CHG
- Request
22 B0 06 - Service 22
DID B006 - Module
DA44 → 44 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 26 voltage 500E_BAT_CELL_26_V
- Request
22 A1 02 - Service 22
DID A102 - Module
DA44 → 44 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 27 state of charge 500E_BAT_CELL_27_ST_CHG
- Request
22 B0 06 - Service 22
DID B006 - Module
DA44 → 44 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 27 voltage 500E_BAT_CELL_27_V
- Request
22 A1 02 - Service 22
DID A102 - Module
DA44 → 44 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 28 state of charge 500E_BAT_CELL_28_ST_CHG
- Request
22 B0 06 - Service 22
DID B006 - Module
DA44 → 44 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 28 voltage 500E_BAT_CELL_28_V
- Request
22 A1 02 - Service 22
DID A102 - Module
DA44 → 44 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 29 state of charge 500E_BAT_CELL_29_ST_CHG
- Request
22 B0 06 - Service 22
DID B006 - Module
DA44 → 44 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 29 voltage 500E_BAT_CELL_29_V
- Request
22 A1 02 - Service 22
DID A102 - Module
DA44 → 44 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 30 state of charge 500E_BAT_CELL_30_ST_CHG
- Request
22 B0 06 - Service 22
DID B006 - Module
DA44 → 44 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 30 voltage 500E_BAT_CELL_30_V
- Request
22 A1 02 - Service 22
DID A102 - Module
DA44 → 44 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 31 state of charge 500E_BAT_CELL_31_ST_CHG
- Request
22 B0 06 - Service 22
DID B006 - Module
DA44 → 44 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 31 voltage 500E_BAT_CELL_31_V
- Request
22 A1 02 - Service 22
DID A102 - Module
DA44 → 44 - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 32 state of charge 500E_BAT_CELL_32_ST_CHG
- Request
22 B0 06 - Service 22
DID B006 - Module
DA44 → 44 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 32 voltage 500E_BAT_CELL_32_V
- Request
22 A1 02 - Service 22
DID A102 - Module
DA44 → 44 - Every
1 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 33 state of charge 500E_BAT_CELL_33_ST_CHG
- Request
22 B0 06 - Service 22
DID B006 - Module
DA44 → 44 - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 33 voltage 500E_BAT_CELL_33_V
- Request
22 A1 02 - Service 22
DID A102 - Module
DA44 → 44 - Every
1 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 34 state of charge 500E_BAT_CELL_34_ST_CHG
- Request
22 B0 06 - Service 22
DID B006 - Module
DA44 → 44 - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 34 voltage 500E_BAT_CELL_34_V
- Request
22 A1 02 - Service 22
DID A102 - Module
DA44 → 44 - Every
1 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 35 state of charge 500E_BAT_CELL_35_ST_CHG
- Request
22 B0 06 - Service 22
DID B006 - Module
DA44 → 44 - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 35 voltage 500E_BAT_CELL_35_V
- Request
22 A1 02 - Service 22
DID A102 - Module
DA44 → 44 - Every
1 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 36 state of charge 500E_BAT_CELL_36_ST_CHG
- Request
22 B0 06 - Service 22
DID B006 - Module
DA44 → 44 - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 36 voltage 500E_BAT_CELL_36_V
- Request
22 A1 02 - Service 22
DID A102 - Module
DA44 → 44 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 37 state of charge 500E_BAT_CELL_37_ST_CHG
- Request
22 B0 07 - Service 22
DID B007 - Module
DA44 → 44 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 37 voltage 500E_BAT_CELL_37_V
- Request
22 A1 03 - Service 22
DID A103 - Module
DA44 → 44 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 38 state of charge 500E_BAT_CELL_38_ST_CHG
- Request
22 B0 07 - Service 22
DID B007 - Module
DA44 → 44 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 38 voltage 500E_BAT_CELL_38_V
- Request
22 A1 03 - Service 22
DID A103 - Module
DA44 → 44 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 39 state of charge 500E_BAT_CELL_39_ST_CHG
- Request
22 B0 07 - Service 22
DID B007 - Module
DA44 → 44 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 39 voltage 500E_BAT_CELL_39_V
- Request
22 A1 03 - Service 22
DID A103 - Module
DA44 → 44 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 40 state of charge 500E_BAT_CELL_40_ST_CHG
- Request
22 B0 07 - Service 22
DID B007 - Module
DA44 → 44 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 40 voltage 500E_BAT_CELL_40_V
- Request
22 A1 03 - Service 22
DID A103 - Module
DA44 → 44 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 41 state of charge 500E_BAT_CELL_41_ST_CHG
- Request
22 B0 07 - Service 22
DID B007 - Module
DA44 → 44 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 41 voltage 500E_BAT_CELL_41_V
- Request
22 A1 03 - Service 22
DID A103 - Module
DA44 → 44 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 42 state of charge 500E_BAT_CELL_42_ST_CHG
- Request
22 B0 07 - Service 22
DID B007 - Module
DA44 → 44 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 42 voltage 500E_BAT_CELL_42_V
- Request
22 A1 03 - Service 22
DID A103 - Module
DA44 → 44 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 43 state of charge 500E_BAT_CELL_43_ST_CHG
- Request
22 B0 07 - Service 22
DID B007 - Module
DA44 → 44 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 43 voltage 500E_BAT_CELL_43_V
- Request
22 A1 03 - Service 22
DID A103 - Module
DA44 → 44 - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 44 state of charge 500E_BAT_CELL_44_ST_CHG
- Request
22 B0 07 - Service 22
DID B007 - Module
DA44 → 44 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 44 voltage 500E_BAT_CELL_44_V
- Request
22 A1 03 - Service 22
DID A103 - Module
DA44 → 44 - Every
1 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 45 state of charge 500E_BAT_CELL_45_ST_CHG
- Request
22 B0 07 - Service 22
DID B007 - Module
DA44 → 44 - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 45 voltage 500E_BAT_CELL_45_V
- Request
22 A1 03 - Service 22
DID A103 - Module
DA44 → 44 - Every
1 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 46 state of charge 500E_BAT_CELL_46_ST_CHG
- Request
22 B0 07 - Service 22
DID B007 - Module
DA44 → 44 - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 46 voltage 500E_BAT_CELL_46_V
- Request
22 A1 03 - Service 22
DID A103 - Module
DA44 → 44 - Every
1 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 47 state of charge 500E_BAT_CELL_47_ST_CHG
- Request
22 B0 07 - Service 22
DID B007 - Module
DA44 → 44 - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 47 voltage 500E_BAT_CELL_47_V
- Request
22 A1 03 - Service 22
DID A103 - Module
DA44 → 44 - Every
1 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 48 state of charge 500E_BAT_CELL_48_ST_CHG
- Request
22 B0 07 - Service 22
DID B007 - Module
DA44 → 44 - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 48 voltage 500E_BAT_CELL_48_V
- Request
22 A1 03 - Service 22
DID A103 - Module
DA44 → 44 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 49 state of charge 500E_BAT_CELL_49_ST_CHG
- Request
22 B0 08 - Service 22
DID B008 - Module
DA44 → 44 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 49 voltage 500E_BAT_CELL_49_V
- Request
22 A1 04 - Service 22
DID A104 - Module
DA44 → 44 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 50 state of charge 500E_BAT_CELL_50_ST_CHG
- Request
22 B0 08 - Service 22
DID B008 - Module
DA44 → 44 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 50 voltage 500E_BAT_CELL_50_V
- Request
22 A1 04 - Service 22
DID A104 - Module
DA44 → 44 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 51 state of charge 500E_BAT_CELL_51_ST_CHG
- Request
22 B0 08 - Service 22
DID B008 - Module
DA44 → 44 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 51 voltage 500E_BAT_CELL_51_V
- Request
22 A1 04 - Service 22
DID A104 - Module
DA44 → 44 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 52 state of charge 500E_BAT_CELL_52_ST_CHG
- Request
22 B0 08 - Service 22
DID B008 - Module
DA44 → 44 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 52 voltage 500E_BAT_CELL_52_V
- Request
22 A1 04 - Service 22
DID A104 - Module
DA44 → 44 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 53 state of charge 500E_BAT_CELL_53_ST_CHG
- Request
22 B0 08 - Service 22
DID B008 - Module
DA44 → 44 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 53 voltage 500E_BAT_CELL_53_V
- Request
22 A1 04 - Service 22
DID A104 - Module
DA44 → 44 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 54 state of charge 500E_BAT_CELL_54_ST_CHG
- Request
22 B0 08 - Service 22
DID B008 - Module
DA44 → 44 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 54 voltage 500E_BAT_CELL_54_V
- Request
22 A1 04 - Service 22
DID A104 - Module
DA44 → 44 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 55 state of charge 500E_BAT_CELL_55_ST_CHG
- Request
22 B0 08 - Service 22
DID B008 - Module
DA44 → 44 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 55 voltage 500E_BAT_CELL_55_V
- Request
22 A1 04 - Service 22
DID A104 - Module
DA44 → 44 - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 56 state of charge 500E_BAT_CELL_56_ST_CHG
- Request
22 B0 08 - Service 22
DID B008 - Module
DA44 → 44 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 56 voltage 500E_BAT_CELL_56_V
- Request
22 A1 04 - Service 22
DID A104 - Module
DA44 → 44 - Every
1 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 57 state of charge 500E_BAT_CELL_57_ST_CHG
- Request
22 B0 08 - Service 22
DID B008 - Module
DA44 → 44 - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 57 voltage 500E_BAT_CELL_57_V
- Request
22 A1 04 - Service 22
DID A104 - Module
DA44 → 44 - Every
1 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 58 state of charge 500E_BAT_CELL_58_ST_CHG
- Request
22 B0 08 - Service 22
DID B008 - Module
DA44 → 44 - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 58 voltage 500E_BAT_CELL_58_V
- Request
22 A1 04 - Service 22
DID A104 - Module
DA44 → 44 - Every
1 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 59 state of charge 500E_BAT_CELL_59_ST_CHG
- Request
22 B0 08 - Service 22
DID B008 - Module
DA44 → 44 - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 59 voltage 500E_BAT_CELL_59_V
- Request
22 A1 04 - Service 22
DID A104 - Module
DA44 → 44 - Every
1 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 60 state of charge 500E_BAT_CELL_60_ST_CHG
- Request
22 B0 08 - Service 22
DID B008 - Module
DA44 → 44 - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 60 voltage 500E_BAT_CELL_60_V
- Request
22 A1 04 - Service 22
DID A104 - Module
DA44 → 44 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 61 state of charge 500E_BAT_CELL_61_ST_CHG
- Request
22 B0 09 - Service 22
DID B009 - Module
DA44 → 44 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 61 voltage 500E_BAT_CELL_61_V
- Request
22 A1 05 - Service 22
DID A105 - Module
DA44 → 44 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 62 state of charge 500E_BAT_CELL_62_ST_CHG
- Request
22 B0 09 - Service 22
DID B009 - Module
DA44 → 44 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 62 voltage 500E_BAT_CELL_62_V
- Request
22 A1 05 - Service 22
DID A105 - Module
DA44 → 44 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 63 state of charge 500E_BAT_CELL_63_ST_CHG
- Request
22 B0 09 - Service 22
DID B009 - Module
DA44 → 44 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 63 voltage 500E_BAT_CELL_63_V
- Request
22 A1 05 - Service 22
DID A105 - Module
DA44 → 44 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 64 state of charge 500E_BAT_CELL_64_ST_CHG
- Request
22 B0 09 - Service 22
DID B009 - Module
DA44 → 44 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 64 voltage 500E_BAT_CELL_64_V
- Request
22 A1 05 - Service 22
DID A105 - Module
DA44 → 44 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 65 state of charge 500E_BAT_CELL_65_ST_CHG
- Request
22 B0 09 - Service 22
DID B009 - Module
DA44 → 44 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 65 voltage 500E_BAT_CELL_65_V
- Request
22 A1 05 - Service 22
DID A105 - Module
DA44 → 44 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 66 state of charge 500E_BAT_CELL_66_ST_CHG
- Request
22 B0 09 - Service 22
DID B009 - Module
DA44 → 44 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 66 voltage 500E_BAT_CELL_66_V
- Request
22 A1 05 - Service 22
DID A105 - Module
DA44 → 44 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 67 state of charge 500E_BAT_CELL_67_ST_CHG
- Request
22 B0 09 - Service 22
DID B009 - Module
DA44 → 44 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 67 voltage 500E_BAT_CELL_67_V
- Request
22 A1 05 - Service 22
DID A105 - Module
DA44 → 44 - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 68 state of charge 500E_BAT_CELL_68_ST_CHG
- Request
22 B0 09 - Service 22
DID B009 - Module
DA44 → 44 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 68 voltage 500E_BAT_CELL_68_V
- Request
22 A1 05 - Service 22
DID A105 - Module
DA44 → 44 - Every
1 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 69 state of charge 500E_BAT_CELL_69_ST_CHG
- Request
22 B0 09 - Service 22
DID B009 - Module
DA44 → 44 - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 69 voltage 500E_BAT_CELL_69_V
- Request
22 A1 05 - Service 22
DID A105 - Module
DA44 → 44 - Every
1 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 70 state of charge 500E_BAT_CELL_70_ST_CHG
- Request
22 B0 09 - Service 22
DID B009 - Module
DA44 → 44 - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 70 voltage 500E_BAT_CELL_70_V
- Request
22 A1 05 - Service 22
DID A105 - Module
DA44 → 44 - Every
1 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 71 state of charge 500E_BAT_CELL_71_ST_CHG
- Request
22 B0 09 - Service 22
DID B009 - Module
DA44 → 44 - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 71 voltage 500E_BAT_CELL_71_V
- Request
22 A1 05 - Service 22
DID A105 - Module
DA44 → 44 - Every
1 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 72 state of charge 500E_BAT_CELL_72_ST_CHG
- Request
22 B0 09 - Service 22
DID B009 - Module
DA44 → 44 - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 72 voltage 500E_BAT_CELL_72_V
- Request
22 A1 05 - Service 22
DID A105 - Module
DA44 → 44 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 73 state of charge 500E_BAT_CELL_73_ST_CHG
- Request
22 B0 0A - Service 22
DID B00A - Module
DA44 → 44 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 73 voltage 500E_BAT_CELL_73_V
- Request
22 A1 06 - Service 22
DID A106 - Module
DA44 → 44 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 74 state of charge 500E_BAT_CELL_74_ST_CHG
- Request
22 B0 0A - Service 22
DID B00A - Module
DA44 → 44 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 74 voltage 500E_BAT_CELL_74_V
- Request
22 A1 06 - Service 22
DID A106 - Module
DA44 → 44 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 75 state of charge 500E_BAT_CELL_75_ST_CHG
- Request
22 B0 0A - Service 22
DID B00A - Module
DA44 → 44 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 75 voltage 500E_BAT_CELL_75_V
- Request
22 A1 06 - Service 22
DID A106 - Module
DA44 → 44 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 76 state of charge 500E_BAT_CELL_76_ST_CHG
- Request
22 B0 0A - Service 22
DID B00A - Module
DA44 → 44 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 76 voltage 500E_BAT_CELL_76_V
- Request
22 A1 06 - Service 22
DID A106 - Module
DA44 → 44 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 77 state of charge 500E_BAT_CELL_77_ST_CHG
- Request
22 B0 0A - Service 22
DID B00A - Module
DA44 → 44 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 77 voltage 500E_BAT_CELL_77_V
- Request
22 A1 06 - Service 22
DID A106 - Module
DA44 → 44 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 78 state of charge 500E_BAT_CELL_78_ST_CHG
- Request
22 B0 0A - Service 22
DID B00A - Module
DA44 → 44 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 78 voltage 500E_BAT_CELL_78_V
- Request
22 A1 06 - Service 22
DID A106 - Module
DA44 → 44 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 79 state of charge 500E_BAT_CELL_79_ST_CHG
- Request
22 B0 0A - Service 22
DID B00A - Module
DA44 → 44 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 79 voltage 500E_BAT_CELL_79_V
- Request
22 A1 06 - Service 22
DID A106 - Module
DA44 → 44 - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 80 state of charge 500E_BAT_CELL_80_ST_CHG
- Request
22 B0 0A - Service 22
DID B00A - Module
DA44 → 44 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 80 voltage 500E_BAT_CELL_80_V
- Request
22 A1 06 - Service 22
DID A106 - Module
DA44 → 44 - Every
1 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 81 state of charge 500E_BAT_CELL_81_ST_CHG
- Request
22 B0 0A - Service 22
DID B00A - Module
DA44 → 44 - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 81 voltage 500E_BAT_CELL_81_V
- Request
22 A1 06 - Service 22
DID A106 - Module
DA44 → 44 - Every
1 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 82 state of charge 500E_BAT_CELL_82_ST_CHG
- Request
22 B0 0A - Service 22
DID B00A - Module
DA44 → 44 - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 82 voltage 500E_BAT_CELL_82_V
- Request
22 A1 06 - Service 22
DID A106 - Module
DA44 → 44 - Every
1 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 83 state of charge 500E_BAT_CELL_83_ST_CHG
- Request
22 B0 0A - Service 22
DID B00A - Module
DA44 → 44 - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 83 voltage 500E_BAT_CELL_83_V
- Request
22 A1 06 - Service 22
DID A106 - Module
DA44 → 44 - Every
1 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 84 state of charge 500E_BAT_CELL_84_ST_CHG
- Request
22 B0 0A - Service 22
DID B00A - Module
DA44 → 44 - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 84 voltage 500E_BAT_CELL_84_V
- Request
22 A1 06 - Service 22
DID A106 - Module
DA44 → 44 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 85 state of charge 500E_BAT_CELL_85_ST_CHG
- Request
22 B0 0B - Service 22
DID B00B - Module
DA44 → 44 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 85 voltage 500E_BAT_CELL_85_V
- Request
22 A1 07 - Service 22
DID A107 - Module
DA44 → 44 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 86 state of charge 500E_BAT_CELL_86_ST_CHG
- Request
22 B0 0B - Service 22
DID B00B - Module
DA44 → 44 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 86 voltage 500E_BAT_CELL_86_V
- Request
22 A1 07 - Service 22
DID A107 - Module
DA44 → 44 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 87 state of charge 500E_BAT_CELL_87_ST_CHG
- Request
22 B0 0B - Service 22
DID B00B - Module
DA44 → 44 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 87 voltage 500E_BAT_CELL_87_V
- Request
22 A1 07 - Service 22
DID A107 - Module
DA44 → 44 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 88 state of charge 500E_BAT_CELL_88_ST_CHG
- Request
22 B0 0B - Service 22
DID B00B - Module
DA44 → 44 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 88 voltage 500E_BAT_CELL_88_V
- Request
22 A1 07 - Service 22
DID A107 - Module
DA44 → 44 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 89 state of charge 500E_BAT_CELL_89_ST_CHG
- Request
22 B0 0B - Service 22
DID B00B - Module
DA44 → 44 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 89 voltage 500E_BAT_CELL_89_V
- Request
22 A1 07 - Service 22
DID A107 - Module
DA44 → 44 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 90 state of charge 500E_BAT_CELL_90_ST_CHG
- Request
22 B0 0B - Service 22
DID B00B - Module
DA44 → 44 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 90 voltage 500E_BAT_CELL_90_V
- Request
22 A1 07 - Service 22
DID A107 - Module
DA44 → 44 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 91 state of charge 500E_BAT_CELL_91_ST_CHG
- Request
22 B0 0B - Service 22
DID B00B - Module
DA44 → 44 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 91 voltage 500E_BAT_CELL_91_V
- Request
22 A1 07 - Service 22
DID A107 - Module
DA44 → 44 - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 92 state of charge 500E_BAT_CELL_92_ST_CHG
- Request
22 B0 0B - Service 22
DID B00B - Module
DA44 → 44 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 92 voltage 500E_BAT_CELL_92_V
- Request
22 A1 07 - Service 22
DID A107 - Module
DA44 → 44 - Every
1 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 93 state of charge 500E_BAT_CELL_93_ST_CHG
- Request
22 B0 0B - Service 22
DID B00B - Module
DA44 → 44 - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 93 voltage 500E_BAT_CELL_93_V
- Request
22 A1 07 - Service 22
DID A107 - Module
DA44 → 44 - Every
1 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 94 state of charge 500E_BAT_CELL_94_ST_CHG
- Request
22 B0 0B - Service 22
DID B00B - Module
DA44 → 44 - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 94 voltage 500E_BAT_CELL_94_V
- Request
22 A1 07 - Service 22
DID A107 - Module
DA44 → 44 - Every
1 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 95 state of charge 500E_BAT_CELL_95_ST_CHG
- Request
22 B0 0B - Service 22
DID B00B - Module
DA44 → 44 - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 95 voltage 500E_BAT_CELL_95_V
- Request
22 A1 07 - Service 22
DID A107 - Module
DA44 → 44 - Every
1 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 96 state of charge 500E_BAT_CELL_96_ST_CHG
- Request
22 B0 0B - Service 22
DID B00B - Module
DA44 → 44 - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 96 voltage 500E_BAT_CELL_96_V
- Request
22 A1 07 - Service 22
DID A107 - Module
DA44 → 44 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Battery cell 97 state of charge 500E_BAT_CELL_97_ST_CHG
- Request
22 B0 0C - Service 22
DID B00C - Module
DA44 → 44 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 98 state of charge 500E_BAT_CELL_98_ST_CHG
- Request
22 B0 0C - Service 22
DID B00C - Module
DA44 → 44 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 99 state of charge 500E_BAT_CELL_99_ST_CHG
- Request
22 B0 0C - Service 22
DID B00C - Module
DA44 → 44 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 100 state of charge 500E_BAT_CELL_100_ST_CHG
- Request
22 B0 0C - Service 22
DID B00C - Module
DA44 → 44 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 101 state of charge 500E_BAT_CELL_101_ST_CHG
- Request
22 B0 0C - Service 22
DID B00C - Module
DA44 → 44 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 102 state of charge 500E_BAT_CELL_102_ST_CHG
- Request
22 B0 0C - Service 22
DID B00C - Module
DA44 → 44 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 103 state of charge 500E_BAT_CELL_103_ST_CHG
- Request
22 B0 0C - Service 22
DID B00C - Module
DA44 → 44 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 104 state of charge 500E_BAT_CELL_104_ST_CHG
- Request
22 B0 0C - Service 22
DID B00C - Module
DA44 → 44 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 105 state of charge 500E_BAT_CELL_105_ST_CHG
- Request
22 B0 0C - Service 22
DID B00C - Module
DA44 → 44 - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 106 state of charge 500E_BAT_CELL_106_ST_CHG
- Request
22 B0 0C - Service 22
DID B00C - Module
DA44 → 44 - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery cell 107 state of charge 500E_BAT_CELL_107_ST_CHG
- Request
22 B0 0C - Service 22
DID B00C - Module
DA44 → 44 - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery coolant inlet temperature 500E_BAT_COOLING_INLET_T
- Request
22 A0 21 - Service 22
DID A021 - Module
DA44 → 44 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val − 32768)- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2020 to 2026.
Battery coolant outlet temperature 500E_BAT_COOLING_OUTLET_T
- Request
22 A0 21 - Service 22
DID A021 - Module
DA44 → 44 - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val − 32768)- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2020 to 2026.
Battery heater inlet temperature 500E_BAT_HEATER_INLET_T
- Request
22 40 53 - Service 22
DID 4053 - Module
DA42 → 42 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Battery heater outlet temperature 500E_BAT_HEATER_OUTLET_T
- Request
22 40 53 - Service 22
DID 4053 - Module
DA42 → 42 - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Battery heater, actual power consumption 500E_BAT_HEATER_ACT_POWER
- Request
22 40 52 - Service 22
DID 4052 - Module
DA42 → 42 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 20)- Range
- 0 to 1310700
- Unit
- Number
In testing for 2020 to 2026.
Battery heater, desired power consumption 500E_BAT_HEATER_DES_POWER
- Request
22 40 52 - Service 22
DID 4052 - Module
DA42 → 42 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 20)- Range
- 0 to 1310700
- Unit
- Number
In testing for 2020 to 2026.
Battery module temperature sensor 1 500E_BAT_MODULE_T_SENS_1
- Request
22 A2 00 - Service 22
DID A200 - Module
DA44 → 44 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Battery module temperature sensor 2 500E_BAT_MODULE_T_SENS_2
- Request
22 A2 00 - Service 22
DID A200 - Module
DA44 → 44 - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Battery module temperature sensor 3 500E_BAT_MODULE_T_SENS_3
- Request
22 A2 00 - Service 22
DID A200 - Module
DA44 → 44 - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Battery module temperature sensor 4 500E_BAT_MODULE_T_SENS_4
- Request
22 A2 00 - Service 22
DID A200 - Module
DA44 → 44 - Every
5 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Battery module temperature sensor 5 500E_BAT_MODULE_T_SENS_5
- Request
22 A2 00 - Service 22
DID A200 - Module
DA44 → 44 - Every
5 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Battery module temperature sensor 6 500E_BAT_MODULE_T_SENS_6
- Request
22 A2 00 - Service 22
DID A200 - Module
DA44 → 44 - Every
5 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Battery module temperature sensor 7 500E_BAT_MODULE_T_SENS_7
- Request
22 A2 00 - Service 22
DID A200 - Module
DA44 → 44 - Every
5 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Battery module temperature sensor 8 500E_BAT_MODULE_T_SENS_8
- Request
22 A2 00 - Service 22
DID A200 - Module
DA44 → 44 - Every
5 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Battery module temperature sensor 9 500E_BAT_MODULE_T_SENS_9
- Request
22 A2 00 - Service 22
DID A200 - Module
DA44 → 44 - Every
5 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Battery module temperature sensor 10 500E_BAT_MODULE_T_SENS_10
- Request
22 A2 00 - Service 22
DID A200 - Module
DA44 → 44 - Every
5 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Battery module temperature sensor 11 500E_BAT_MODULE_T_SENS_11
- Request
22 A2 00 - Service 22
DID A200 - Module
DA44 → 44 - Every
5 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Battery module temperature sensor 12 500E_BAT_MODULE_T_SENS_12
- Request
22 A2 00 - Service 22
DID A200 - Module
DA44 → 44 - Every
5 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Battery module temperature sensor 13 500E_BAT_MODULE_T_SENS_13
- Request
22 A2 00 - Service 22
DID A200 - Module
DA44 → 44 - Every
5 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Battery module temperature sensor 14 500E_BAT_MODULE_T_SENS_14
- Request
22 A2 00 - Service 22
DID A200 - Module
DA44 → 44 - Every
5 s - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Battery module temperature sensor 15 500E_BAT_MODULE_T_SENS_15
- Request
22 A2 00 - Service 22
DID A200 - Module
DA44 → 44 - Every
5 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Battery module temperature sensor 16 500E_BAT_MODULE_T_SENS_16
- Request
22 A2 00 - Service 22
DID A200 - Module
DA44 → 44 - Every
5 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Battery module temperature sensor 17 500E_BAT_MODULE_T_SENS_17
- Request
22 A2 00 - Service 22
DID A200 - Module
DA44 → 44 - Every
5 s - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Battery module temperature sensor 18 500E_BAT_MODULE_T_SENS_18
- Request
22 A2 00 - Service 22
DID A200 - Module
DA44 → 44 - Every
5 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Battery pack link voltage 500E_BAT_PACK_LINK_V
- Request
22 A0 11 - Service 22
DID A011 - Module
DA44 → 44 - Every
5 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 V
- Unit
- V
In testing for 2020 to 2026.
Battery temperature 3 500E_BAT_T_3
- Request
22 A0 21 - Service 22
DID A021 - Module
DA44 → 44 - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val − 32768)- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2020 to 2026.
Battery voltage 500E_BAT_V
- Request
22 01 9E - Service 22
DID 019E - Module
DA42 → 42 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 43 ÷ 2500)- Range
- 0 to 1127 V
- Unit
- V
In testing for 2020 to 2026.
Battery voltage, BCM 500E_BCM_BAT_VConfirmed
Pelican can show this parameter as the starter battery voltage.
- Request
22 10 04 - Service 22
DID 1004 - Module
DA40 → 40 - Every
30 s - Testing for 2012 to 2021, 2023 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
Confirmed for 2022. In testing for 2012 to 2021, 2023 to 2026.
Battery voltage, cell sum 500E_BAT_V_CELL_SUM
Pelican can show this parameter as the traction battery voltage.
- Request
22 A0 11 - Service 22
DID A011 - Module
DA44 → 44 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 V
- Unit
- V
In testing for 2020 to 2026.
Battery voltage, module sum 500E_BAT_V_MODULE_SUM
- Request
22 A0 11 - Service 22
DID A011 - Module
DA44 → 44 - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 V
- Unit
- V
In testing for 2020 to 2026.
Distance since last charge events 1 500E_DIST_SINCE_CHG_1
- Request
22 A0 70 - Service 22
DID A070 - Module
DA44 → 44 - Every
30 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
(val × 0.160935)- Range
- 0 to 10546 km
- Unit
- km
In testing for 2020 to 2026.
Distance since last charge events 2 500E_DIST_SINCE_CHG_2
- Request
22 A0 71 - Service 22
DID A071 - Module
DA44 → 44 - Every
30 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
(val × 0.160935)- Range
- 0 to 10546 km
- Unit
- km
In testing for 2020 to 2026.
Drive motor HV battery voltage 500E_EMOTOR_HVBAT_V
- Request
22 30 62 - Service 22
DID 3062 - Module
DA42 → 42 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 50)- Range
- 0 to 1310 V
- Unit
- V
In testing for 2020 to 2026.
Drive motor HV input voltage 500E_EMOTOR_HV_INPUT_V
- Request
22 B5 62 - Service 22
DID B562 - Module
DA42 → 42 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 50)- Range
- 0 to 1310 V
- Unit
- V
In testing for 2020 to 2026.
Electric A/C compressor HV input voltage 500E_EAC_HV_V_INPUT
- Request
22 40 12 - Service 22
DID 4012 - Module
DA42 → 42 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 4)- Range
- 0 to 1020 V
- Unit
- V
In testing for 2020 to 2026.
High voltage battery current from the battery pack control module 500E_HVBAT_CURRENT_BPCM
- Request
22 03 01 - Service 22
DID 0301 - Module
DA42 → 42 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 10 − 512.1)- Range
- -512 to 6041 A
- Unit
- A
In testing for 2020 to 2026.
Highest battery temperature 500E_MAX_CELL_T
- Request
22 A0 09 - Service 22
DID A009 - Module
DA44 → 44 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val − 32768)- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2020 to 2026.
Highest cell state of charge 500E_MAX_CELL_ST_CHG
- Request
22 A0 10 - Service 22
DID A010 - Module
DA44 → 44 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Highest cell voltage 500E_MAX_CELL_V
- Request
22 A0 09 - Service 22
DID A009 - Module
DA44 → 44 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Highest voltage cell number 500E_MAX_V_CELL_NUMBER
- Request
22 A0 09 - Service 22
DID A009 - Module
DA44 → 44 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
HV battery current 500E_HVBAT_CURRENT
Pelican can show this parameter as the traction battery current.
- Request
22 A0 0A - Service 22
DID A00A - Module
DA44 → 44 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 20 − 1638.4)- Range
- -1638 to 1638 A
- Unit
- A
In testing for 2012 to 2026.
HV battery current capacity 500E_HVBAT_CAP
- Request
22 A0 29 - Service 22
DID A029 - Module
DA44 → 44 - Every
1 s - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 Ah
- Unit
- Ah
In testing for 2020 to 2026.
HV battery lifetime amp-hours 1 500E_HVBAT_AH_1
- Request
22 A0 01 - Service 22
DID A001 - Module
DA44 → 44 - Every
30 s - Testing
Bits 24 to 47 of the reply, 24 bits.
- Formula
(val ÷ 10)- Range
- 0 to 1677721 Ah
- Unit
- Ah
In testing for 2020 to 2026.
HV battery lifetime amp-hours 2 500E_HVBAT_AH_2
- Request
22 A0 01 - Service 22
DID A001 - Module
DA44 → 44 - Every
30 s - Testing
Bits 48 to 71 of the reply, 24 bits.
- Formula
(val ÷ 10)- Range
- 0 to 1677721 Ah
- Unit
- Ah
In testing for 2020 to 2026.
HV battery lifetime energy 1 500E_HVBAT_KWH_1
- Request
22 A0 01 - Service 22
DID A001 - Module
DA44 → 44 - Every
30 s - Testing
Bits 72 to 95 of the reply, 24 bits.
- Formula
(val ÷ 10)- Range
- 0 to 1677721 kWh
- Unit
- kWh
In testing for 2020 to 2026.
HV battery lifetime energy 2 500E_HVBAT_KWH_2
- Request
22 A0 01 - Service 22
DID A001 - Module
DA44 → 44 - Every
30 s - Testing
Bits 96 to 119 of the reply, 24 bits.
- Formula
(val ÷ 10)- Range
- 0 to 1677721 kWh
- Unit
- kWh
In testing for 2020 to 2026.
HV battery nominal capacity 500E_HVBAT_CAP_NOMINAL
- Request
22 A0 29 - Service 22
DID A029 - Module
DA44 → 44 - Every
1 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 Ah
- Unit
- Ah
In testing for 2020 to 2026.
HV battery state of charge 500E_HVBAT_ST_CHG
Pelican can show this parameter as the state of charge.
- Request
22 A0 10 - Service 22
DID A010 - Module
DA44 → 44 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
HV battery state of charge, estimate 1 500E_HVBAT_ST_CHG_EST_1
- Request
22 A0 10 - Service 22
DID A010 - Module
DA44 → 44 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
HV battery state of charge, estimate 3 500E_HVBAT_ST_CHG_EST_3
- Request
22 A0 10 - Service 22
DID A010 - Module
DA44 → 44 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
HV battery state of health 500E_HVBAT_SOH
Pelican can show this parameter as the state of health.
- Request
22 A0 29 - Service 22
DID A029 - Module
DA44 → 44 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 655.35)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
HV bus voltage 500E_HV_BUS_V
- Request
22 40 52 - Service 22
DID 4052 - Module
DA42 → 42 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 2020 to 2026.
Lowest battery temperature 500E_MIN_CELL_T
- Request
22 A0 09 - Service 22
DID A009 - Module
DA44 → 44 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
(val − 32768)- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2020 to 2026.
Lowest cell state of charge 500E_MIN_CELL_ST_CHG
- Request
22 A0 10 - Service 22
DID A010 - Module
DA44 → 44 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Lowest cell voltage 500E_MIN_CELL_V
- Request
22 A0 09 - Service 22
DID A009 - Module
DA44 → 44 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2020 to 2026.
Lowest voltage cell number 500E_MIN_V_CELL_NUMBER
- Request
22 A0 09 - Service 22
DID A009 - Module
DA44 → 44 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.