The FIAT 500e has 7 Connectables, parameters that Pelican can monitor automatically.
● Confirmed◆ In testing○ Supported× Not supported
State of charge
HV battery state of charge 500E_HVBAT_ST_CHG
Pelican can show this parameter as the state of charge.
- Request
22 A0 10 - Service 22
DID A010 - Module
DA44 → 44 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
State of health
HV battery state of health 500E_HVBAT_SOH
Pelican can show this parameter as the state of health.
- Request
22 A0 29 - Service 22
DID A029 - Module
DA44 → 44 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 655.35)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Odometer
Odometer 500E_ODO
Pelican can show this parameter as the odometer.
- Request
22 30 27 - Service 22
DID 3027 - Module
DA42 → 42 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
(val × 32187 ÷ 200000)- Range
- 0 to 2700041 km
- Unit
- km
In testing for 2020 to 2026.
Starter battery voltage
12V battery voltage 500E_AUX_BAT_V
Pelican can show this parameter as the starter battery voltage.
- Request
22 A0 42 - Service 22
DID A042 - Module
DA44 → 44 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2012 to 2026.
Battery voltage, BCM 500E_BCM_BAT_VConfirmed
Pelican can show this parameter as the starter battery voltage.
- Request
22 10 04 - Service 22
DID 1004 - Module
DA40 → 40 - Every
30 s - Testing for 2012 to 2021, 2023 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
Confirmed for 2022. In testing for 2012 to 2021, 2023 to 2026.
Traction battery current
HV battery current 500E_HVBAT_CURRENT
Pelican can show this parameter as the traction battery current.
- Request
22 A0 0A - Service 22
DID A00A - Module
DA44 → 44 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 20 − 1638.4)- Range
- -1638 to 1638 A
- Unit
- A
In testing for 2012 to 2026.
Traction battery voltage
Battery voltage, cell sum 500E_BAT_V_CELL_SUM
Pelican can show this parameter as the traction battery voltage.
- Request
22 A0 11 - Service 22
DID A011 - Module
DA44 → 44 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 V
- Unit
- V
In testing for 2020 to 2026.