Engine parameters
The FIAT 500e has 17 engine parameters.
● Confirmed◆ In testing○ Supported× Not supported
Air conditioning refrigerant pressure 500E_AC_REFRIGERANT_P
- Request
22 40 01 - Service 22
DID 4001 - Module
DA42 → 42 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127 bar
- Unit
- bar
In testing for 2020 to 2026.
Air heater core temperature 500E_AIRHEATER_CORE_T
- Request
22 40 55 - Service 22
DID 4055 - Module
DA42 → 42 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Air heater current 500E_AIRHEATER_CURRENT
- Request
22 40 55 - Service 22
DID 4055 - Module
DA42 → 42 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val ÷ 4)- Range
- 0 to 63.75 A
- Unit
- A
In testing for 2020 to 2026.
Air heater power consumption 500E_AIRHEATER_POWER_CONS
- Request
22 40 55 - Service 22
DID 4055 - Module
DA42 → 42 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Drive motor coolant inlet temperature 500E_EMOTOR_CLT_INLET_T
- Request
22 30 65 - Service 22
DID 3065 - Module
DA42 → 42 - Every
5 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Drive motor coolant outlet temperature 500E_EMOTOR_CLT_OUTLET_T
- Request
22 30 65 - Service 22
DID 3065 - Module
DA42 → 42 - Every
5 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Drive motor inverter temperature 0 500E_EMOTOR_INVERTER_T_0
- Request
22 30 65 - Service 22
DID 3065 - Module
DA42 → 42 - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Drive motor inverter temperature 1 500E_EMOTOR_INVERTER_T_1
- Request
22 30 65 - Service 22
DID 3065 - Module
DA42 → 42 - Every
5 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Drive motor inverter temperature 2 500E_EMOTOR_INVERTER_T_2
- Request
22 30 65 - Service 22
DID 3065 - Module
DA42 → 42 - Every
5 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Drive motor inverter temperature model 500E_EMOTOR_INVERTER_T
- Request
22 30 65 - Service 22
DID 3065 - Module
DA42 → 42 - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Drive motor PCB temperature 500E_EMOTOR_PCB_T
- Request
22 30 65 - Service 22
DID 3065 - Module
DA42 → 42 - Every
5 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Drive motor rotor temperature 500E_EMOTOR_ROTOR_T
- Request
22 30 65 - Service 22
DID 3065 - Module
DA42 → 42 - Every
5 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Drive motor stator temperature 500E_EMOTOR_STATOR_T
- Request
22 30 65 - Service 22
DID 3065 - Module
DA42 → 42 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Drive motor torque achieved 500E_EMOTOR_TQ_ACHIEVED
- Request
22 30 64 - Service 22
DID 3064 - Module
DA42 → 42 - Every
250 ms - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 50 − 500)- Range
- -500 to 810 N·m
- Unit
- N·m
In testing for 2020 to 2026.
Drive motor torque limit 500E_EMOTOR_TQ_LIM
- Request
22 30 63 - Service 22
DID 3063 - Module
DA42 → 42 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 50 − 500)- Range
- -500 to 810 N·m
- Unit
- N·m
In testing for 2020 to 2026.
Drive motor torque, commanded 500E_EMOTOR_TQ_CMD
- Request
22 30 64 - Service 22
DID 3064 - Module
DA42 → 42 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 50 − 500)- Range
- -500 to 810 N·m
- Unit
- N·m
In testing for 2020 to 2026.
Electric A/C compressor HV current 500E_EAC_HV_CURRENT
- Request
22 40 11 - Service 22
DID 4011 - Module
DA42 → 42 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 5)- Range
- 0 to 51 A
- Unit
- A
In testing for 2020 to 2026.