ECU parameters
The Scion FR-S has 28 ECU parameters.
● Confirmed◆ In testing○ Supported× Not supported
A/F sensor #1 FRS_A_F_SENSOR_1
- Request
22 10 BE - Service 22
DID 10BE - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 1.99 ÷ 255)- Range
- 0 to 1.99
- Unit
- Number
In testing for 2013 to 2016.
Alternator duty FRS_ALTERNATOR_DUTY
- Request
22 10 B2 - Service 22
DID 10B2 - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 2013 to 2016.
Canister purge control valve duty cycle FRS_CPC_VALVE_DUTY_CYCLE
- Request
22 10 AE - Service 22
DID 10AE - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 2013 to 2016.
Cylinder monitor #1 FRS_MONITOR_1
- Request
22 13 14 - Service 22
DID 1314 - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383.75 rpm
- Unit
- rpm
In testing for 2013 to 2016.
Cylinder monitor #2 FRS_MONITOR_2
- Request
22 13 15 - Service 22
DID 1315 - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383.75 rpm
- Unit
- rpm
In testing for 2013 to 2016.
Cylinder monitor #3 FRS_MONITOR_3
- Request
22 13 16 - Service 22
DID 1316 - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383.75 rpm
- Unit
- rpm
In testing for 2013 to 2016.
Cylinder monitor #4 FRS_MONITOR_4
- Request
22 13 17 - Service 22
DID 1317 - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383.75 rpm
- Unit
- rpm
In testing for 2013 to 2016.
Engine starting time FRS_ENGINE_STARTING_TIME
- Request
22 12 9C - Service 22
DID 129C - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 ms
- Unit
- ms
In testing for 2013 to 2016.
Exhaust gas recirculation steps FRS_EGR_STEPS
- Request
22 10 B1 - Service 22
DID 10B1 - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2016.
Exhaust gas recirculation valve opening angle FRS_EGR_VALVE_OPENING_ANGLE
- Request
22 11 1C - Service 22
DID 111C - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °
- Unit
- °
In testing for 2013 to 2016.
Exhaust OCV duty left FRS_EXHAUST_OCV_DUTY_LEFT
- Request
22 10 EF - Service 22
DID 10EF - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 2013 to 2016.
Exhaust OCV duty right FRS_EXHAUST_OCV_DUTY_RIGHT
- Request
22 10 EE - Service 22
DID 10EE - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 2013 to 2016.
Intake VVT advance angle left FRS_INTAKE_VVT_ADVANCE_LEFT
- Request
22 10 B5 - Service 22
DID 10B5 - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °
- Unit
- °
In testing for 2013 to 2016.
Intake VVT advance angle right FRS_INTAKE_VVT_ADVANCE_RIGHT
- Request
22 10 B4 - Service 22
DID 10B4 - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °
- Unit
- °
In testing for 2013 to 2016.
Interior heater FRS_INTERIOR_HEATER
- Request
22 11 2C - Service 22
DID 112C - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2016.
Lock up duty ratio FRS_LOCK_UP_DUTY_RATIO
- Request
22 10 C8 - Service 22
DID 10C8 - Module
7A3 → 7AB - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127.5 %
- Unit
- %
In testing for 2013 to 2016.
Oil control valve duty left FRS_OCV_DUTY_LEFT
- Request
22 10 B7 - Service 22
DID 10B7 - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 2013 to 2016.
Oil control valve duty right FRS_OCV_DUTY_RIGHT
- Request
22 10 B6 - Service 22
DID 10B6 - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 2013 to 2016.
Oil level switch FRS_OIL_LEVEL_SWITCH
- Request
22 12 4C - Service 22
DID 124C - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2016.
Oil supply value, duty left FRS_OSV_DUTY_LEFT
- Request
22 10 E9 - Service 22
DID 10E9 - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 2013 to 2016.
Oil supply value, duty right FRS_OSV_DUTY_RIGHT
- Request
22 10 E8 - Service 22
DID 10E8 - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 2013 to 2016.
Radiator fan control FRS_RADIATOR_FAN
- Request
22 10 AB - Service 22
DID 10AB - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 200 %
- Unit
- %
In testing for 2013 to 2016.
Roughness monitor #1 FRS_ROUGHNESS_MONITOR_1
- Request
22 11 0B - Service 22
DID 110B - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2016.
Roughness monitor #2 FRS_ROUGHNESS_MONITOR_2
- Request
22 11 0C - Service 22
DID 110C - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2016.
Roughness monitor #3 FRS_ROUGHNESS_MONITOR_3
- Request
22 11 0D - Service 22
DID 110D - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2016.
Roughness monitor #4 FRS_ROUGHNESS_MONITOR_4
- Request
22 11 0E - Service 22
DID 110E - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2016.
Target intake manifold pressure FRS_TARGET_INTAKE_MANIFOLD_PRESSURE
- Request
22 11 18 - Service 22
DID 1118 - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 50 kPa
- Unit
- kPa
In testing for 2013 to 2016.
Throttle motor duty FRS_THROTTLE_MOTOR_DUTY
- Request
22 10 DE - Service 22
DID 10DE - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 0.784 − 100)- Range
- -100 to 99.92 %
- Unit
- %